DRW171148AA

Dimensions Specifications
MULTI FUNCTION TIMER 48 15
64.5
50
(unit: mm)
Model AT8N-

AT8N SERIES Function


※1
Multi Function Timer
Control time setting range 0.05 sec to 100 hour
INSTRUCTION MANUAL •100-240VACᜠ 50/60Hz, 24-240VDCᜡ universal

44.8
Power supply
•24VACᜠ 50/60Hz, 24VDCᜡ universal • 12VDCᜡ
Allowable voltage range 90 to 110% of the rated voltage
Thank you for choosing our Autonics product. •Max. 4.3VA (100-240VACᜠ), Max. 2W (24-240VDCᜡ)
Power consumption
Please read the following safety considerations before use. Bracket Panel cut-out •Max. 4.5VA (24VACᜠ), Max. 2W (24VDCᜡ) •Max. 1.5W (12VDCᜡ)
48.6 20 Min. 65 Return time Max. 100ms
Safety Considerations 45 5 Time operation Power ON Start
※Please observe all safety considerations for safe and proper product operation to avoid hazards. Time limit DPDT (2c) or Instantaneous SPDT (1c)+Time limit SPDT (1c)
Control Contact type
※Safety considerations are categorized as follows. selectable by output operation mode
45 +0.6
0 output
Contact capacity 250VACᜠ 5A resistive load

36

16
44.9
Warning Failure to follow these instructions may result in serious injury or death.
Caution Failure to follow these instructions may result in personal injury or product damage. Relay Mechanical Min. 10,000,000 operations
Min. 65 life cycle Electrical
※The symbols used on the product and instruction manual represent the following 45 +0.6
0
Min. 100,000 operations (250VAC 5A resistive load)
symbol represents caution due to special circumstances in which hazards may occur. Repeat error Max. ±0.2% ±10ms
55 15
Setting error Max. ±5% ±50ms
Warning 21 Voltage error Max. ±0.5%
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury 31 Temperature error Max. ±2%
or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, Insulation resistance 100MΩ (at 500VDC megger)
railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) 56
Failure to follow this instruction may result in fire, personal injury, or economic loss. Dielectric strength 2,000VAC 50/60Hz for 1 minute
2. Install on a device panel to use. Environ- Ambient temp. -10 to 55℃, Storage: -25 to 65℃
Failure to follow this instruction may result in electric shock or fire.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Output Operation Mode [t: Setting time, t>t-a, Rt: Return time, Rt1>Rt] ment Ambient humid. 35 to 85%RH, Storage: 35 to 85%RH
Failure to follow this instruction may result in electric shock or fire. Mode Time chart Approval
4. Check 'Connections' before wiring. t Rt1 t Rt1 t-a Accessory Bracket
Failure to follow this instruction may result in fire. A ※
Power 2-7 Weight 2 Approx. 134.12g (approx. 86.71g)
5. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or fire. ※1: Refer to time specifications for control time setting range by model.
Time limit contact N.C. 1-4 (8-5) ※2: The weight includes packaging. The weight in parenthesis is for unit only.
Caution Power ON Time limit contact N.O. 1-3 (8-6) ※Environment resistance is rated at no freezing or condensation.
Delay
1. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage.
Time limit output indicator Connections
2. Use dry cloth to clean the unit, and do not use water or organic solvent. Operation/Power indicator When selecting [A], [F] When selecting [A1], [B], [F1], [I]
Failure to follow this instruction may result in electric shock or fire. t Rt1 t Rt1 t-a output operation mode output operation mode
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, A1
radiant heat, vibration, impact, or salinity may be present. Power 2-7 4 5 4 5
Failure to follow this instruction may result in fire or explosion. Time limit contact N.C. 8-5 CONTACT CONTACT
4. Keep metal chip, dust, and wire residue from flowing into the unit. 0.5sec 0.5sec 3 6 OUT: 3 6 OUT:
Failure to follow this instruction may result in fire or product damage. Power ON Time limit contact N.O. 8-6
250VAC 5A 250VAC 5A
Delay 1 Instantaneous contact N.C. 1-4 RESISTIVE RESISTIVE
2 7 2 7
Ordering Information (One-shot Instantaneous contact N.O. 1-3
Time limit output indicator 1 8
LOAD
1 8
LOAD
output) (Time limit 1c) (Time limit 1c) (Instantaneous (Time limit 1c)
AT 8 N - Operation/Power indicator 1c)
Power supply No mark 100-240VAC 50/60Hz, 24-240VDC ※One-shot output is 0.5sec fixed.
※1 ※1
1 12VDC t Rt1 t Rt1 t-a
2 24VAC 50/60Hz, 24VDC B ※1: AC/DC voltage: 100-240VAC 50/60Hz, 24-240VDC
Power 2-7 : 24VAC 50/60Hz, 24VDC
Time operation Time limit 2c or DC voltage: 12VDC
Time limit contact N.C. 8-5
N Instantaneous 1c + Time limit 1c

Number of plug pins


selectable by output operation mode
Power ON
Time limit contact N.O. 8-6
Instantaneous contact N.C. 1-4
Cautions during Use
8 8-pin plug type Delay 2 1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
Instantaneous contact N.O. 1-3 2. 12VDC, 24VDC, 24VAC power supply should be insulated and limited voltage/current or Class 2, SELV
Item
AT Analog Timer Time limit output indicator power supply device.
※Sockets (PG-08, PS-08(N)) are sold separately. Operation/Power indicator 3. When supplying or turning off the power, use a switch or etc. to avoid chattering.
4. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
t t t-a Rt1 t t t 5. In order to avoid leakage current flowing, connect resistance and condenser as (Figure 2).
F
Unit Description Power 2-7 If connect as (Figure 1), it may cause malfunction due to leakage current.
(Figure 1) (Figure 2)
Operation/Power indicator Time limit contact N.C. 1-4 (8-5)
Leakage
(Flashes for timer operation, Time limit output indicator Flicker Time limit contact N.O. 1-3 (8-6) current R
Power T Timer Power T
Turns ON for timer stop) (OFF Start) Time limit output indicator C Timer
R C
Time range indication Output operation mode indicator Operation/Power indicator
6. Keep away from high voltage lines or power lines to prevent inductive noise.
Time range setting switch (A, A1, B, F, F1 mode) t t t-a Rt1 t t t In case installing power line and input signal line closely, use line filter or varistor at power line and shielded
F1
Power 2-7 wire at input signal line.
Time unit indication Do not use near the equipment which generates strong magnetic force or high frequency noise.
(sec, min, hour, 10h mode) Output operation mode setting switch Time limit contact N.C. 8-5 7. Change setting time, time range, operation mode or etc. after turning off the power of the timer.
Time limit contact N.O. 8-6 8. This unit may be used in the following environments.
Time Specifications Flicker 1
(ON Start)
Instantaneous contact N.C. 1-4 ①Indoors (in the environment condition rated in 'Specifications')
②Altitude max. 2,000m
Instantaneous contact N.O. 1-3 ③Pollution degree 2
Time range Time unit Time setting range Time range Time unit Time setting range
Time limit output indicator ④Installation category II
0.5 0.05 to 0.5 sec 0.5 0.05 to 0.5 hour
1.0 0.1 to 1 sec 1.0 0.1 to 1 hour
Operation/Power indicator
Major Products
sec hour t Rt1 t Rt1 t-a Photoelectric Sensors Temperature Controllers
5 0.5 to 5 sec 5 0.5 to 5 hour I Fiber Optic Sensors Temperature/Humidity Transducers
Power 2-7 Door Sensors SSRs/Power Controllers
10 1 to 10 sec 10 1 to 10 hour Door Side Sensors Counters
Time limit contact N.C. 8-5
0.5 0.05 to 0.5 min 0.5 0.5 to 5 hour Area Sensors Timers
Time limit contact N.O. 8-6 Proximity Sensors Panel Meters
1.0 0.1 to 1 min 1.0 1 to 10 hour Pressure Sensors Tachometers/Pulse (Rate) Meters http://www.autonics.com
min 10h Instantaneous contact N.C. 1-4 Rotary Encoders Display Units
5 0.5 to 5 min 5 5 to 50 hour Interval Connector/Sockets Sensor Controllers
Instantaneous contact N.O. 1-3 HEADQUARTERS:
10 1 to 10 min 10 10 to 100 hour Switching Mode Power Supplies
18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
Time limit output indicator Control Switches/Lamps/Buzzers
※The above specifications are subject to change and some models may be discontinued without I/O Terminal Blocks & Cables South Korea, 48002
Operation/Power indicator Stepper Motors/Drivers/Motion Controllers TEL: 82-51-519-3232
notice. Graphic/Logic Panels E-mail: sales@autonics.com
※Be sure to follow cautions written in the instruction manual and the technical descriptions ※In case of F, F1 output operation mode, setting time should be over 100ms. Field Network Devices
(catalog, homepage). If not, it may cause abnormal output operation due to under 100ms of setting time. Laser Marking System (Fiber, Co₂, Nd: YAG) DRW171148AA