2
l y/lx = 2.2, ⇒ One way slab (With Imposed loads of 4 KN/m )
2 2 6 2
250N/mm k = Mmax / fcubd = 4.15 x 10 / 20 x 1000 x 90 = 0.0256 < 0.156
1/2
Z = 90 { 0.5 + [0.25 – (0.0256/0.9)] } = 87.4mm > 0.95d =
6 2
85.5mm As(required) = 4.15 x 10 / 0.87 x 250 x 85.5 = 223 mm
Elevation view
Floor finishes = 0.75 kPa (assumed) x (6/2 + 4/2) x (5.6/2 + 4.4/2) = 18.75 kN
Column = 0.45 x 0.4 x 3.46 x 24 = 15 kN
Brickwall = 20 x 0.175 x (6/2 + 4/2) x (5.6/2 + 4.4/2) = 60.55 kN
Main Beam = 24 x 0.6m x 0.8m x (6/2 + 4/2) = 57.6 kN
Secondary Beam = 24 x 0.25 x 0.45 x (6/2 + 4/2) = 13.5 kN
Total = 255.4 kN
(ii) Live Load:
2 100 kN
LL = 4 KN//m (assumed) x (6/2 + 4/2) x (5.6/2 + 4.4/2) =
nd
(2c) Third Storey or 2 Upper Storey:
(i) Dead Load:
2 = 56.25 KN
ROOF Materials = 1.5KN//m x 5 x 5
Strip Footing Size of 2m width (instead of 4m) x 4m (Span Length) x .75 Thk
Refer to Section 5.6 of the report, the tested foundation allowable bearing soil
2 2
pressure is 140.00 KN//m > 123.71 KN//m which is O.K.!