iO Series

Intelligent Control
iO Series
Submittal Guide

iO Series

Initiating
Devices
Intelligent fire alarm solutions for small buildings

Notification
Appliances
Hazardous Location
Devices
Door Holders
& Relays

An EDWARDS brand.
Se
w.
S
e e w
e no
h a ha t’s possible
w
..
t
's w.
no
possible
Intelligent Control
iO Series
Project: ___________________________

Contact: ___________________________

Date: ___________________________

Initiating
Devices
Thank you for giving us the opportunity to provide this submittal for an iO
Series Life Safety System. iO Series combines analog addressable detection
with technologically advanced sensor diagnostic capabilities. Together these
innovations offer unsurpassed stability, reliability, and flexibility.

This guide provides a summary of these innovations and includes a

Notification
Appliances
comprehensive presentation of related system components and devices.
Products we are submitting for your consideration are indicated by a
checkmark in the margins of the pages that follow.

More detailed information can be found in individual data sheets dedicated


to each product. All these sheets, along with guide specifications and other

Hazardous Location
useful product information, are available electronically on our LifeLines
CD-ROM. This exhaustive collection of life safety related literature is fully

Devices
searchable.

Thank you for giving us the opportunity to provide this submittal. Please do
not hesitate to contact us should you require further information.
Door Holders
& Relays

_____________________________
iO Series Initiating Notification Hazardous Location Door Holders
Intelligent Control Devices Appliances Devices & Relays

iii
Intelligent fire alarm solutions for small buildings
iO Series
Submittal Guide
iO Series Submittal Guide
Intelligent fire alarm solutions for small buildings
© 2014 United Technologies Corporation
All rights reserved. Specifications subject to change without notice.
EDWARDS is part of UTC Building & Industrial Systems.
1016 Corporate Park Drive, Mebane, NC 27302
85005-0132, Issue 3
Wiring diagrams provided herein are for information and reference only and are not to be used for installation pur-
poses. Consult the appropriate installation documents for wiring and configuration details.
This guidebook is for information only and is not intended as a substitute for verbatim legislated requirements. For
authoritative specifications regarding the application of life safety, security, and access control systems, consult
current editions of applicable codes and standards. For authoritative interpretation of those codes and standards,
consult your local authority having jurisdiction.
While every effort has been made to ensure the accuracy and completeness of this guidebook, the authors and
publishers assume no responsibility for errors, inaccuracies, omissions, or any inconsistencies herein.
EST, Genesis Series, and Signature Series are trademarks of United Technologies Corporation.
iO Series Life Safety Systems

Intelligent Control
iO Series
Cohesive, iO Series Analog
System Specifications....................................................... 2
1

comprehensive Control Panels................................................................... 3


Option Cards..................................................................... 4

analog addressable Power Supplies................................................................. 6


Remote annunciation........................................................ 8

fire alarm for small Accessories..................................................................... 10

Initiating
buildings.

Devices
Intelligent Analog Initiating Devices 11
Combination CO/Fire Detectors....................................... 12
With control panels, devices, and accessories all Fire Detectors.................................................................. 13
Duct Smoke Detectors.................................................... 13
engineered to work in unison, iO Series systems Detector Bases............................................................... 14
provide reliable performance and the advanced Detector Accessories...................................................... 15
Input/Output Modules..................................................... 16
features you need for successful installation and
Pull Stations.................................................................... 22
worry-free operation. Best of all, iO Series leaves

Notification
Appliances
you in control – not hemmed in by a limited product Notification Appliances 23
line. EST’s extensive range of fire alarm products Wall Strobes, Horns & Chimes......................................... 25
Wall Speakers and Speaker-strobes................................ 26
gives you the freedom to tailor each system to the
LED Strobes, Horn-Strobes............................................. 26
particular needs of the building – and the budget Ceiling Speakers, Horns, and Strobes............................. 27

of the building owner – while a robust feature set Low Frequency Horns and Strobes................................. 27
Outdoor Speakers and Speaker-Strobes......................... 28
leaves plenty of room for upgrades, expansions,

Hazardous Location
Outdoor Horns and Horn-Strobes................................... 29
and retrofits long into the future. Harsh Environment Signals.............................................. 30
Genesis Signal Master..................................................... 31
But innovative features tell only part of the

Devices
Audible Signals................................................................ 31
story: when you specify iO Series you’re getting Audio Notification System................................................ 32
Accessories..................................................................... 33
more than outstanding value in a fire alarm panel;
you’re benefitting from a whole family of control,
Hazardous Location Devices 35
detection, and notification appliances finely tuned Initiating Devices............................................................. 36
to work together – engineered and tested to func- Notification Appliances.................................................... 37

tion as a single unified system.


Door Holders

Built on the successes of the past, and meet-


Door Holders & Relays 38
& Relays

Door Holders................................................................... 38
ing the needs of the future, iO Series is the chang- Relays............................................................................. 39
ing face of small building fire detection today. SPDT Relays................................................................... 39

v
See what’s
possible now.

D e t e c t i o n & A l a r m S i n c e 1 8 7 2 .

Mass Notification • Smoke Detection • Graphical Monitoring and Control • Instant Messaging • Aspirating Smoke Detectors • Industrial
Signaling • Voice Evacuation • Smoke Control • Fire Suppression • Intercom • Timekeeping • CO Detection • Heat Detection •
Audible & Visible Signaling • Voicemail Messaging • Duct Smoke Detection • Giant Voice • Electronic Signage • Area of Rescue
iO Series Intelligent Control

Specifications p. 2

Control Panels p. 3

Intelligent Control
Option Cards p. 4

iO Series
Power Supplies p. 6

Remote annunciation p. 8

Accessories p. 10

iO Series Intelligent Control

Initiating
Devices
iO Series life safety systems are a powerful intelligent solu- Signals with a difference
tion for small to mid-sized buildings. Advanced analog tech- iO Series NACs are configurable to fully support the ad-
nology delivers the benefits of flexible system installation, vanced signaling technology of Edwards Genesis and En-
while a clean and easy-to-operatate user interface makes hanced Integrity notification appliances. These devices offer
panel operation and system maintenance quick and intuitive. precision synchronization of strobes to UL 1971 standards.
For Genesis devices, enabling this feature allows connected
The smart choice horns to be silenced while strobes on the same two-wire

Notification
Signature Series electronic addressing eliminates the tedium circuit continue to flash until the panel is reset.

Appliances
of setting dipswitches, and automatic device mapping en-
sures that each device resides on the system at its correct Clear-cut remote annunciation
location. Meanwhile, innovative programming features allow Remote annunciation is a strong suit of iO Series. Up to
the system designer to customize powerful built-in features eight annunciators can be installed on a single system.
to precisely suit the needs of Compatible annunciators include
the building owner. a range of LED and LCD models
that provide zone or point an-
Flexibility built right in nunciation, as well as common
Two fully-programmable front control capabilities.

Hazardous Location
panel switch/LED combi-
iO Series also supports graphic
nations provide an added
annunciation with optional RA
measure of flexibility. Their

Devices
Graphic Annunicator interface
slide-in labels take the mystery
modules. Each interface provides
out of custom applications,
common control, indicators, and
and present a clean finished
32 LEDS.
appearance.
A complete line of accessories
Perfect for retrofits iO Series life safety systems are
iO Series is particularly well- supported by a complete line of
suited to retrofit applications. intelligent detectors, modules and
All connections are made over related equipment, each of which
standard wiring – no shielded
Door Holders

is fully tuned and tested to oper-


cable required. This means
& Relays

ate in concert with one another to


that in most situations existing provide highly reliable service and
wiring can be used to upgrade years of trouble-free operation.
a legacy control panel to iO
Series technology without the
expense or disruption of rewir-
ing the entire building.

1
Intelligent Control

iO Series Intelligent Control

Specifications
iO Series

Specifications iO64 iO500


Device loops 1 loop Class B or Class A, 1 loop, expandable to 2, Class A or B,
supports up to 64 devices each loop supports up to 250 devices
Notification appliance 2 Class B, Class A optional, 2.5 amps 4 Class B or 2 Class A, 2.5 amps each
circuits each
Power supply 3.75 A FWR total at 120/230 VAC 60 6.0 A total, 2.5 A max. per circuit at
Hz 120/230 VAC 60 Hz. 5.0 A total at
3.0 A FWR total at 230 VAC 50 Hz 230VAC 50 Hz, 2.5 A max. per circuit
0.5 amps aux power 0.5 amps aux power
NAC Operating 24 VDC. NAC minimum voltage: 19.5 VDC @ 20.4 V battery voltage

Up to 20,000 feet of wiring per data loop!


SLC Loop operating 20 V peak-to-peak
Primary power 120 VAC, 60 Hz, 230 VAC 50-60 Hz
Aux Power 1 Continuous circuit: 24 VDC nominal at 500 mA. A SMK module is required when
using the SIGA-UM module to support two-wire smoke detectors.
Aux Power 2 Resettable circuit: 24 VDC nominal at 500 mA.
Auxiliary output 19 to 25.7 VDC
Base panel current Standby: 155 mA Alarm: 204 mA Standby: 172 mA, Alarm: 267 mA
Battery placement Accommodates up to 10 A/H Accommodates up to 18 A/H batteries.
batteries. Use external cabinet for Use external cabinet for larger batteries.
larger batteries.
Batteries Batteries must be sealed lead acid type only. Maximum charging capacity = 26
Ah.
Loop circuit Maximum loop resistance: 66 Ω. Maximum loop resistance: 66 Ω.
Maximum loop capacitance: 0.7 µF. Maximum loop capacitance: 0.5 µF.
Style 4, 6, and 7 wiring. 64 isolators Style 4, 6, and 7 wiring. 64 isolators
maximum maximum.
Loop max detector 1.5 mA (see the UL and ULC compatibility list for your panel
standby current for the maximum quantity of detectors per circuit)
Compatibility ID 100
Alarm contact Form C 24 VDC @ 1 A (resistive load)
Trouble contact Form C 24 VDC @ 1 A (resistive load)
Supervisory contact Form A 24 VDC @ 1 A (resistive load)
Environmental Temperature: 0 to 49°C (32 to 120°F). Humidity: 0 to 93% RH, noncondensing
Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 sq mm)
Serial communications Voltage: 2.55 V. Current: 30 mA max
Remote annunciator 8 drops max, RS-485 Class B, Class A
Input zones 16 max. 32 max.
Agency Listing UL, CSFM and ULC. FDNY and FM approved.

iO500: one loop that supports up to 250 intelligent devices. Optional second loop (iO500)
Can be expanded to two loops. Each loop supports up to 125
detectors and up to 125 modules.

iO64: one loop that supports up to


64 intelligent devices of any type.

iO64: 2 Class B or 2 optional Class A NACs


iO500: 4 Class B or 2 Class A NACs
Ethernet Diagram represents an
Any combination of up to eight LCD, LED, iO500 system wired for
and graphic serial annunciators DACT/Dialer Class A operation with
a full complement of
option cards.
RS-232

Relays: Two Form C, one Form A

2
iO Series Intelligent Control

SUBMIT

 

Intelligent Control
Control Panels  


  

iO Series
Standard Features Dimensions
All iO Series life safety systems feature an attractive design that Surface mounting holes
D2 D3
fits with any decor. Its distinctive doorfront offers a contemporary
look that’s available with red or silver finishes. All LED indicators
and its large backlit display remain easy to see at all times.

Semi-flush mounting holes


• Supports Signature Series intelligent modules and detectors
• Form C contacts for alarm and trouble, Form A for supervisory
• Electronic addressing with automatic device mapping D1 D4

Initiating
• Optional Ethernet port for diagnostics, programming and a variety

Devices
of reports
• Two programmable switches with LEDs and custom labeling
Surface mounting holes
• Supports Genesis horn silence over two
wires and UL 1971-compliant strobe
synchronization D6
• Supports up to eight serial annunciators, D5
(LCD, LED-only, and graphic interface).
Panel dimensions, in (cm)
• Can use existing wiring for most retrofit Model D1* D2 D3 D4 D5* D6
applications 28.0 3.85 9.0 22.0 15.75 10.25
iO500
• Upload/download remotely or locally (71.1) (9.8) (22.8) (55.8) (40.0) (26.0)

Notification
21.50 3.85 7.5 15.5 14.25 10.25

Appliances
• Two-level maintenance alert reporting iO64
(54.6) (9.8) (19.0) (39.4) (36.2) (26.0)
• Pre-alarm and alarm verification by point * Add 1-1/2 in. (3.81 cm) to D1 and D5 dimensions for trim kit.

iO500 Intelligent Multi-Loop Systems, Data Sheet 85005-0130


iO500G 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 115VAC, English.
iO500G-2 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 230VAC, English
iO500GC 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 115VAC, Canadian English
iO500G-F 1 Loop System, 500 analog point capacity, 4 NACs, gray door, surface enclosure, 115VAC, Canadian French
iO500GD 1 Loop System, 500 analog point capacity, two-line dialer, 4 NACs, Gray door, surface enclosure, 115VAC, English.

Hazardous Location
iO500R 1 Loop System, 500 analog point capacity, 4 NACs, red Door, surface enclosure, 115VAC, English.
iO500R-2 1 Loop System, 500 analog point capacity, 4 NACs, red door, surface enclosure, 230VAC, English

Devices
iO500RD 1 Loop System, 500 analog point capacity, two-line dialer, 4 NACs, Red Door, surface enclosure, 115VAC, English.
D16L-iO-2 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to right of display.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM2 Flush mount trim, black

iO64 Intelligent Single Loop Systems, Data Sheet 85005-0131


iO64G 1 Loop System, 64 analog point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, English.
iO64GD 1 Loop System, 64 analog point capacity, 2 Class B NACs, 2 Line Dialer, Gray door, surface enclosure, 115VAC, English.
iO64R 1 Loop System, 64 analog point capacity, 2 Class B NACs, Red Door, surface enclosure, 115VAC, English.
iO64RD 1 Loop System, 64 analog point capacity, 2 Class B NACs, 2 Line Dialer, Red Door, surface enclosure, 115VAC, English.
Door Holders

iO64G-2 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 230VAC, English.
& Relays

iO64R-2 1 Loop System, 64 point capacity, 2 Class B NACs, Red door, surface enclosure, 230VAC, English.
iO64GL 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, English, Canadian.
iO64GL-F 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, French, Canadian.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM1 Flush mount trim, black

3
iO Series
SUBMIT
Intelligent Control

 
  Option Cards
Intelligent Control





iO Series

SA-232 RS-232
interface

SA-CLA Class A
Module

XAL250 Loop Expander Card

iO-Series panels are supported by a complete line of modules and related equipment that
enhance performance and extend system capabilities. Option cards are easy to install and set
up. They simply plug directly into the control panel main circuit board or are connected to it
with a ribbon cable. After installation, terminals remain easily accessible for quick connection of
field wiring. The cabinet provides ample room for wire routing, keeping wiring neat and easy to
service at all times.

SA-CLA wiring
TB2 on main NAC1
+ + SA-CLA Class A Module
circuit board NAC1+
NAC2
+ + The SA-CLA card provides Class A capability for NAC and annuncia-
NAC2+ tor wiring. Its terminal block provides the wiring connection for NAC
return wiring. The card is required for annunciator Class A wiring even
+ though this wiring does not return to the SA-CLA card. The SA-CLA
is compatible with iO64 control panels only. iO500 panels are Class
+ A ready. The SA-CLA is installed directly to the control panel circuit
Class A card installed
board using its plastic standoffs and plug connection.
on main circuit board

SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board.
SA-ETH wiring
To network
connection
Network cable
SA-ETH Ethernet Interface Card
The SA-ETH card provides a standard 10/100 Base T Ethernet network connection
for connecting to an intranet, a local network, or the Internet. The card can be used
to upload and download panel configuration, history, and current status from the
iO-CU to the panel over the network.
The Ethernet card is installed on the plastic assembly and connects to the main
circuit board via a ribbon cable.
Ethernet card
SA-ETH Ethernet Port, Slave, for Ethernet connection to local area networks. Mounts in cabinet on base plate.

SA-232 wiring
GND (black wire)
TXD (white wire)
SA-232 RS-232 interface
RXD (red wire)
The SA-232 card provides an RS-232 interface with iO-Series panels. It can be used for
connecting a printer to the control panel to print system events. The card also can be used
for connecting a computer to download a configuration program from the iO-CU to the
control panel.
The RS-232 card is installed on the plastic assembly and connects to the main circuit board
via a ribbon cable.

SA-232 Serial Port (RS-232), for connection to printers & computers, mounts in cabinet to base plate

4
iO Series Intelligent Control

SUBMIT

 

Intelligent Control



  

iO Series
SA-DACT Phone line 1
wiring
To wall
Phone line 2 phone jack

Phone cables
RJ31 jacks
(supplied)
SA-DACT Dialer
The SA-DACT provides communications between the control panel and the central
station over a telephone line system. It transmits system status changes (events)
to a compatible digital alarm communicator receiver over the public switched tele-
phone network. The dialer is capable of single, dual, or split reporting of events to

Initiating
Devices
two different account and telephone numbers. The modem feature of the SA-DACT
can also be used for uploading and downloading panel configuration, history, and
current status to a PC running the iO-CU.
The dialer phone lines connect to connectors on the dialer’s main circuit board.
Phone line 1 connects to connector J4 and phone line 2 connects to connector J1.

SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate

SMK Smoke Power Converter

Notification
Appliances
The SMK Smoke Power Converter Module provides a backup power source for
two-wire smoke circuits connected to a Signature data circuit. The SMK monitors 24 VDC
the operating power from the power supply. When power begins to degrade, the auxilliary +
24 VDC
power _
SMK provides the necessary operating voltage to the two-wire smoke detection (notauxilliary
resettable) +
power _
circuits. (not resettable)

SMK Smoke Power Converter Module


Class B wiring

8 7 6 5
SMK + +
Power
8 7 6 in5
- SMK Power+out
+
Power+ in
+
Loop 1 SEC Data Line
+ Power
4 3 2 out
1

Hazardous Location
+ +
- + + 4 3 2 1
Loop 1 PRI
+ - -
Loop Loop Two-wire smoke
detectors

Devices
device device
Loop card Two-wire smoke
detectors
XAL250 Loop Expander Card (iO500 Systems only) 16 15 14 13 3 2 1 12 11 10 9
Class B wiring Class A wiring +
JP1
16 15 14 13 3 2 1 12 11 10 9
Class B Wiring Class A Wiring
+
JP1
- - 8 7 6 5 4 3 2 1
Loop 1 SEC Loop 1 SEC
Data Line
+ +
8 7 6 5 4 3 2 1
- + +- + + Data in +
Loop 1 PRI Loop 1 PRI
+ - -+ - -
Data in
+
Loop Loop Loop Loop Two-wire smoke
device Loopdevice
card device device detectors
Loop card Data Line Two-wire smoke
detectors

The
Class AXAL250
wiring Loop Expander Card provides an additional Signature 16 15 14 13 3 2 1 12 11 10 9
Door Holders

+
Series device loop on the control panel. The card expands the control 16 15 14 13 JP1
3 2 1 12 11 10 9 Terminate
& Relays

+ or to next
panel’s device - capacity to 500 total device addresses, 250 per loop. JP1 UM
Terminate
or to next
Loop 1 SEC 8 7 6 5 4 3 2 1
The card is+compatible with Class B or Class A wiring. It is compatible UM

with iO500 -control panels+only. The + loop expander card mounts in


8 7 6 5 4 3 2 1
Loop 1 PRI Data out
the cabinet+and connects to - connector
- J7 on the main circuit board.
Loop Loop Data out
device device


Loop card Data Line
XAL250 Signature Loop Expansion Module. Adds second loop to iO500 systems, 250 point capacity.

5
iO Series
SUBMIT
Intelligent Control

 
  Power Supplies
Intelligent Control





iO Series

Remote Booster Power Supply


The Remote Booster Power Supply is a self-contained 24 Vdc power supply designed to
augment fire alarm audible and visual power requirements as well as provide power for
auxiliary, access control and security applications. The booster contains all of the necessary
circuits to monitor and charge batteries, control and supervise four Class B or two Class A
NAC circuits and monitor two controlling inputs from external sources.
Simple switch selection provides a wide variety of operational configurations. Each remote
booster power supply is supplied with its own enclosure providing ample space for additional
interface modules and battery compartment.
When used with Genesis Notification appliances, the booster provides the ability to syn-
chronize strobes as well as horn signals. The booster flexibility allows synchronization with
upstream devices, or, the booster may be used to synchronize downstream devices, as
NAC NAC
well as otherSense
boosters andUptheir connected devices.
NAC Series Connection
Sense to ten boosters
Circuit
can be connected
together
Booster
Power Supply BPS notification Powerappliance
Booster
Supply circuits easily configure for either of two signaling rates: 3-3-3
temporal or continuous. This makes the BPS ideal for applications requiring signaling rates
not available from the main panel. It also allows independent setup of a notification appli-
ance circuit without interfering with the main panel and its initiating circuits. In addition to
Sense
NAC
the generated signal rates, the BPS can also be configured to follow the signal rate of the
Parallel Connection
The number of boosters

Booster
mainthatpanel’s notification appliance circuit. This allows seamless expansion of existing NACs.
can be connected
together is limited by wire
Power Supply run length and available current
For comprehensive configuration and wiring details, refer to the BPS Application Guide,
85001-0582.
Parallel Connection
The number of boosters
that can be connected
together is limited by wire
run length and available current

BPS6A 6.5 Amp Booster Power Supply Data Sheet 85005-0125


BPS6A/230 6.5 Amp Booster Power Supply (220V) Data Sheet 85005-0125
BPS10A 10 Amp Booster Power Supply Data Sheet 85005-0125
BPS10A/230 10 Amp Booster Power Supply (220V) Data Sheet 85005-0125
3-TAMP Tamper switch Data Sheet 85005-0125

6
iO Series Intelligent Control

SUBMIT

 

Intelligent Control



  

iO Series
Auxiliary Power Supply (APS)
TB1
Notification
The Auxiliary Power Supply (APS) is a self-

+
NAC1 appliance contained 24 Vdc power supply designed
circuit (NAC)
to augment fire alarm audible and visual
+
NAC2
Notification
power requirements as well as provide
+
NAC3 appliance
circuit (NAC) auxiliary power for life safety and security
+

NAC4
200 mA AUX
applications. The APS contains all of the
TB5

Continuous Input or signaling circuit necessary circuits to monitor and charge


+

IN
Sense 1 COM
+
batteries, control and supervise four Class

Initiating
-
B or two Class A NAC circuits and moni-

Devices
OUT To next signaling device, NAC
IN
+

Sense 2 COM booster, or NAC returning


to existing control panel
tor two controlling inputs from external
OUT
NO sources.
Trouble COM EOL
[3]
NC AC power fail
TB2 monitoring

APS6A 6.5 Amp Auxiliary Power Supply Data Sheet 85005-0127


APS6A/230 6.5 Amp Auxiliary Power Supply (220V) Data Sheet 85005-0127
APS10A 10 Amp Auxiliary Power Supply Data Sheet 85005-0127
APS10A/230 10 Amp Auxiliary Power Supply (220V) Data Sheet 85005-0127

Notification
Appliances
Batteries and Battery Cabinets
12 Volt Batteries  12V4A (4.5 Ah)  12V6A5 (7.2 Ah)  12V10A (11 Ah) Data Sheet 85005-0127
 12V1A2 (1.2 Ah)  12V24A (26 Ah)  12V17A (18 Ah) Data Sheet 85005-0127
6 Volt Batteries  6V8A (8 Ah)  6V10A (12 Ah) Data Sheet 85005-0127
Data Sheet 85005-0127

Hazardous Location
Battery Cabinet  BC-1 (holds up to two 40 Ah batteries)

Devices
Door Holders
& Relays

7
iO Series
SUBMIT
Intelligent Control

 
  Remote annunciation
Intelligent Control





iO Series

Edwards R-Series Annunciators are high-


Power
Fire Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled

performance remote annunciators that provide


Ack/Silence

Reset

Signal Silence

status indication and common controls for


Drill

Lamp Test

compatible fire alarm control panels, including iO- RLCD-C

Series small analog fire alarm systems. This family


of annunciators offers LCD or LED annunciation. Power
Fire Alarm
Supervisory
Ground Fault

Models are available with and without common


Trouble
Controls Enabled
Ack/Silence

controls. Lamp Test

RLCD

There are three R-Series annunciator models, plus an LED-based


Power
Fire Alarm
Power
Fire Alarm
Supervisory
expander. Up to two expanders can be connected to any annun-
ciator. The expander includes 24 pairs of LEDs that extend the
Supervisory
Ground Fault Ground Fault
Trouble Trouble
Controls Enabled Controls Enabled
Ack/Silence Ack/Silence

Reset

Signal Silence
Reset

Signal Silence capabilities of any of the annunciators.


Drill Drill

Lamp Test

All annunciator models include status LEDs and an internal buzzer.


Lamp Test

RLCD-C RLED-C Two models have an LCD text display, and one has 16 pairs of
LEDs for zone annunciation. LCD models feature a large back-lit,
FACP Annunciator Annunciator
RS-485 CH1 (+) IN CH1 (+) IN
Power
Fire Alarm
Supervisory
four by twenty
CH1 +character per line, super-twist
CH1 (–) IN liquid crystal
CH1 (display.
–) IN
Ground Fault
Trouble CH1 – CH1 (+) OUT CH1 (+) OUT

R-Series annunciators and expanders


CH1 (–) OUT are mounted on a standard
Controls Enabled
Ack/Silence
CH2 + CH1 (–) OUT

4-inch square electrical box, usingCH2the (–) IN included mountingCH2


ring.
(–) IN They
CH2 – CH2 (+) IN CH2 (+) IN

can also beLISTEDsurface mounted inCH2locking steel enclosures. Three


Lamp Test

24 VDC (+) OUT CH2 (+) OUT


SUPPLY
different enclosures are available.
CH2 (–) OUT CH2 (–) OUT
RLCD RLED24 24 VDC + 24V (+) IN 24V (+) IN
24 VDC – 24V (–) IN 24V (–) IN

A keyswitch and graphic annunciator interface is available for R-Series annunciator24Vapplications.


(+) OUT The keyswitch
24V (+) OUT en-

ables or disables common controls. The graphic annunicator interface cards supports 32 LEDs and 16 switches on
Power
Fire Alarm 24V (–) OUT 24V (–) OUT
Supervisory
Ground Fault
Trouble

the graphic panel display.


Controls Enabled
Ack/Silence
GROUND GROUND
Reset

Signal Silence

Wiring, Class A Wiring, Class B


Drill

Lamp Test

FACP Annunciator Annunciator


FACP Annunciator Annunciator
RS-485 RLED-C CH1 (+) IN CH1 (+) IN
RS-485 CH1 (+) IN CH1 (+) IN
CH1 + CH1 (–) IN CH1 (–) IN
CH1 + CH1 (–) IN CH1 (–) IN
CH1 – CH1 (+) OUT CH1 (+) OUT
CH1 – CH1 (+) OUT CH1 (+) OUT
CH2 + CH1 (–) OUT CH1 (–) OUT
CH1 (–) OUT CH1 (–) OUT
CH2 – CH2 (+) IN CH2 (+) IN
CH2 (+) IN CH2 (+) IN
CH2 (–) IN CH2 (–) IN
CH2 (–) IN CH2 (–) IN
LISTED 24 VDC CH2 (+) OUT CH2 (+) OUT
LISTED 24 VDC CH2 (+) OUT CH2 (+) OUT
SUPPLY CH2 (–) OUT CH2 (–) OUT SUPPLY CH2 (–) OUT CH2 (–) OUT
24 VDC + 24V (+) IN 24V (+) IN
24 VDC + 24V (+) IN 24V (+) IN
24 VDC – 24V (–) IN 24V (–) IN
24 VDC – 24V (–) IN 24V (–) IN
RLED24 24V (+) OUT 24V (+) OUT
24V (+) OUT 24V (+) OUT
24V (–) OUT 24V (–) OUT
24V (–) OUT 24V (–) OUT

GROUND GROUND
GROUND GROUND

RLCD
FACP
LCD text Annunciator
annunciator without common controls. English.
Annunciator
Data Sheet 85005-0128
Annunciator First Expander Second Expander

RLCD-R
RS-485
LCD text annunciator without common controls. English. Red.OUT
CH1 (+) IN
CH1 (+) IN
IN Data Sheet 85005-0128
OUT IN OUT
CH1 + CH1 (–) IN CH1 (–) IN
V (–) V (–) V (–) V (–) V (–)
RLCDF
CH1 – LCD text CH1
annunciator
(+) OUT without common controls. French.
CH1 (+) OUT
V (+) V (+) Data Sheet 85005-0128
V (+) V (+) V (+)
CH1 (–) OUT CH1 (–) OUT
F F F F F
RLCD-C LCD text CH2
annunciator
(+) IN with common
CH2controls.
(+) IN English. E E Data
E Sheet 85005-0128
E E
CH2 (–) IN CH2 (–) IN
D D D D D
RLCD-CR
LISTED 24 VDC LCD text CH2
annunciator
(+) OUT with common
CH2controls.
(+) OUT English. Red. C C Data
C Sheet 85005-0128
C C
SUPPLY CH2 (–) OUT CH2 (–) OUT
RLCD-CF LCD text 24V
annunciator with common
24Vcontrols. French. Data Sheet 85005-0128
B B B B B
24 VDC + (+) IN (+) IN
A A A A A
24 VDC – 24V (–) IN 24V (–) IN
RLED-C 16-pair LED
24V (+)zone
OUT annunciator with24Vcommon
(+) OUT controls. English. Data Sheet 85005-0128
24V (–) OUT 24V (–) OUT
RLED-CR 16-pair LED zone annunciator with common controls. English. Red. Data Sheet 85005-0128
GROUND GROUND

RLED-CF 16-pair LED zone annunciator with common controls. French. Data Sheet 85005-0128
RLED24 24-pair LED zone expander with expander cable and zone card insert. Data Sheet 85005-0128
RLED24R Annunciator24-pair LEDFirst
zone expander withSecond
Expander
expander
Expander
cable and zone card insert. Red. Data Sheet 85005-0128
OUT IN OUT IN OUT

RKEY V (–) Remote keyV (switch


–) V (–) on plate for enabling
V (–) V (–) or disabling common controls (Lock/Unlock).
Data Sheet 85005-0128
V (+) V (+) V (+) V (+) V (+)
F F F F F
E E E E E
8 D D D D D
C C C C C
B B B B B
iO Series Intelligent Control

SUBMIT

 

Intelligent Control



  

iO Series
Annunciator Enclosures
The RA Remote Annunciator Enclosures provide secure, surface mounted protec-
tion for annunciators and extenders. Each consists of a back plate, hinged cover,
and key lock. The enclosures are 16-gauge welded steel with a white, painted
finish. Each enclosure includes a security lock and two keys. The two- and three-
RA-ENC1
position enclosures have wiring channels for correct routing of interconnections.
The enclosures attach to a standard electrical box, and provide a mounting lip
that takes the place of the integral mounting ring supplied with the annunciators
and expanders.

Initiating
Devices
RA-ENC3

RA-ENC2

RA-ENC1 One-position enclosure for Remote Annunciator. Data Sheet 85005-0128


RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander. Data Sheet 85005-0128
A-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders. Data Sheet 85005-0128
LSRA-SB Surface Mount Box - for R Series single units. Data Sheet 85005-0128

Notification
Appliances
Graphic Annunication
The GCI series of graphic annunicator drivers allow iO control panels to
display events on an LED-based graphic annunciator. The GCI annun-
ciator card supports 32 LEDs on the graphic panel display. It includes
status LEDs and an internal buzzer. The graphic card is supplied with
snap track mounting. It is attached to a plastic mounting rail that requires
two EIA panels.
The annunciator communicates with the control panel on the RS 485

Hazardous Location
data riser, which can be configured for Class A or Class B communica-
tion. The annunciator does not provide ground fault isolation. The driver
card communicates with and is powered by the control panel or by an 24VDC FROM 3-PPS/M 24VDC TO NEXT

Devices
OR 3-BPS/M POWER RISER POWER MODULE

approved power supply. Always ensure that National and Local approv- RS-485 NETWORK DATA RS-485 NETWORK DATA

als and requirements are met when selecting a graphic panel supplier. FROM PREVIOUS PANEL TO NEXT PANEL

GCI Graphic Annunciator Driver Data Sheet 85005-0130

Door Holders
& Relays

9
iO Series
SUBMIT
Intelligent Control

 
  Accessories
Intelligent Control





iO Series

Riser out to next device

City Tie Module or EOL Relay Alarm/Supervisory Wiring

Riser in
Master Box
The City Tie Module provides a simple way of connecting iO
from
Panel CC1 CTM
/MCC1

Series to a local energy fire alarm box or City Master Box. One Data in

2-CTM provides either supervisory or alarm signaling. To config- Municipal


Circuit
ure both supervisory and alarm signaling, two City Tie modules Data out

are required.
CTM City Tie Module Data Sheet 85005-0097

Reverse Polarity Module


Provides three reverse polarity transmitters: one for system common alarm; one for
system common trouble; and, one for system common supervisory.

RPM Reverse Polarity Module Data Sheet 85005-0097

Desktop Serial Printer


The PT-1 series printers are high-speed, nine-pin dot matrix type. It is used to perma-
nently record life safety system changes of state. All printed entries contain the date,
time, event type and a user-defined message for each printed event. The printer is
required in proprietary systems and requires a backup UPS power source. In auxiliary,
local, or remote station systems, the printer is optional.

PT-1S Serial Printer Data Sheet 270020


PT-1S/220 Serial Printer — 220/240Vac Data Sheet 270020

10
iO Series Intelligent Initiating Devices

Combination CO/Fire Detectors p. 12

Fire Detectors p. 13

Duct Smoke Detectors p. 13

Detector Bases p. 14

Detector Accessories p. 15
Signature Series

Intelligent Analog
Input/Output Modules p. 16

Pull Stations p. 22

Initiating Devices

Initiating
Devices
iO Series Signature Series intelligent analog- Automatic Device Mapping – The Signature Loop Con-
addressable system is an entire family of life safety detectors troller learns where each device’s serial number address is
as well as mounting bases, multiple-function input and output installed relative to other devices on the circuit. This map-
modules, and user-friendly maintenance ping function is invaluable for tracking down unexpected
and service tools. or missing device addresses, or finding changes to wiring.
The System Definition Utility program also uses this map-
Making the best of true multisensor capa-
ping feature to produce system layout or As-Built drawings
bility, Signature Series detectors continu-
showing such details as banch wiring (T-taps), device types
ally monitor the protected space with their
and their addresses.
on-board sensors, each of which is finely
tuned to detect a different characteristic Fast Stable Communication – Built-in intelligence means
of combustion. All this informa­tion is

Notification
less information needs to be sent between the device and

Appliances
gathered and run through a sophisticated the Signature Loop Controller, making the circuit less sensi-
algorithm that compares the sensor read- tive to noise and wire characteristics. This renders shielded
ings over time to known signatures of fires. wiring unnecessary. In fact, existing wiring can be used by
Only when a match is found will an alarm Signature Series devices in most retrofit situations.
condition occur. This means that a single
multisensor detector can distinguish be- Testing & Maintenance – Each detector automatically iden-
tween a harmless puff of dust and a wisp tifies when it is dirty or defective and causes a “dirty detector”
of smoke; between hot, humid weather message. The detector’s sensitiv­ity measurement can also
and a serious life safety condition. be transmitted to the loop controller. A sensitivity report may
be printed to satisfy NFPA sensitivity mea­surements. The

Hazardous Location
Self-diagnostics and History Log – Sig- user-friendly maintenance program shows the current state
nature Series devices constantly run self-checks to provide of each detector and other pertinent messages. When the
important maintenance information. The results of these CO sensor’s electrochemical cell reaches its end of life, the
detector signals a trouble condition to the control panel. The

Devices
checks are automatically updated and permanently stored
in the device’s non-volatile memory. sensor/daughterboard module is field-replaceable.
Class B wiring

iO Series Signature Device loop Circuit specifications -


Device loops 1 loop,Loop
expandable
1 SEC to 2, Class ALine
Data or B, each loop
iO Series control panels provide one device +
supporting up to 250 device addresses
loop circuit that can be used with any mix of Com. line voltage LoopMaximum
1 PRI
- +
20 V peek-to-peek
+
Signature Series detectors and modules. The Circuit current
+
0.5 A max Loop
- -
iO500 panel can be expanded to provide a Circuit impedance
Loop
Loop66Ω
card total, 0.5 µF, max
device device
second loop. All loop circuits are supervised
Isolators 64 maximum
for opens, shorts, and grounds.
Door Holders

Class B wiring Class A wiring


& Relays

Class B Class A
- -
Loop 1 SEC Loop 1 SEC
Data Line
+ +
Typical Wiring
- + +- + +
Loop 1 PRI Loop 1 PRI
+ - -+ - -
Loop Loop Loop Loop
device Loopdevice
card device device
Loop card Data Line

Class A wiring

-
11
Loop 1 SEC
+
iO Series
SUBMIT
Intelligent Initiating Devices

 
Intelligent Control




  
iO Series

Combination CO/Fire Detectors


In addition to integrated smoke and heat sensors, Signature Series combination life safety
Initiating
Devices

devices include electrochemical carbon dioxide sensors. CO detection has rapidly become
a standard part of life safety strate­gies everywhere. Monitored CO detection is becoming
mandated with increasing frequency in all types of commercial applications, but particularly
in occupancies such as hotels, rooming houses, dormitories, day care facilities, schools,
hospitals, assisted living facilities, and nursing homes. In fact, more than half of the U.S.
population already lives in states requiring the installation of CO detectors in some com-
mercial occupancies. This is because car­bon monoxide is the leading cause of accidental
poisoning deaths in America. Known as the “Silent Killer,” CO is odorless, tasteless, and
colorless. It claims nearly 500 lives, and results in more than 15,000 hospital visits annually.

Intelligent Carbon Monoxide (CO) Detector


Features the industry’s only field-replaceable CO module. The SIGA2-COS detects carbon monoxide from any source
of combustion and analyzes the sensor data to determine when to initiate a CO-related life safety event.
SIGA2-COS Intelligent Carbon Monoxide (CO) Detector Data Sheet: 85001-0622

Intelligent Multisensor Photoelectric/Heat Detector with CO Sensor


Includes a photoelectric smoke sensor, a fixed-temperature heat sensor, and a carbon monoxide sensor. The detector
analyzes the smoke and heat sensors independently from the CO sensor, and can report a smoke/fire alarm separate
from a CO-related life safety alarm.
SIGA2-PHCOS Intelligent Multisensor Photoelectric/Heat Detector with CO Sensor Data Sheet: 85001-0621

Intelligent Fixed Temperature Heat Detector with CO Sensor


On-board fixed-temperature heat sensor to detect heat from fire – and a field replaceable CO sensor. The detector
analyzes the heat and CO sensors independently, and reports a heat/fire alarm, a CO-related life safely alarm, or both.
SIGA2-HCOS Intelligent Fixed Temperature Heat Detector with CO Sensor Data Sheet: 85001-0620

Intelligent Photoelectric Detector with CO Sensor


Uses a photo-optical sensing chamber to detect smoke, and a field-replaceable CO sensor to detect carbon monoxide.
The detector analyzes the smoke and CO sensors independently to determine whether to initiate smoke/fire alarm, a
CO-related life safely alarm, or both. The two elements can report separately to the system.
SIGA2-PCOS Intelligent Photoelectric Detector with CO Sensor Data Sheet: 85001-0619

12
iO Series Intelligent Initiating Devices

SUBMIT

 
Fire Detectors  


  
Intelligent Multisensor Photoelectric/Heat Detector
Contains a fixed-temperature heat sensor to detect heat from fire and a photoelectric smoke sensor to detect smoke.
Unlike simple multi-criteria detectors, the SIGA2-PHS can report the heat and photo elements as separate event types
— or together. This permits the photo element of the detector to report, for example, a supervisory event during the
day, and an alarm event at night – while the heat element always reports an alarm.
SIGA2-PHS Intelligent Multisensor Photoelectric/Heat Detector Data Sheet: 85001-0621
SIGA-PHS Intelligent 3D Multisensor Detector, White Data Sheet 85001-0247

Initiating
Devices
Intelligent Photoelectric Detector
The workhorse of modern fire alarm systems, this devices includes a photoelectric smoke sensor to detect smoke.
SIGA2-PS Intelligent Photoelectric Detector Data Sheet: 85001-0619
SIGA-PS Intelligent Photoelectric Detector, legacy housing Data Sheet: 85001-0269

Intelligent Rate-of-rise Heat Detector


Includes a rate-of-rise and a fixed-temperature sensor to detect heat from fire.
SIGA2-HRS Intelligent Rate-of-rise Heat Detector Data Sheet: 85001-0620
SIGA-HRS Intelligent Rate-of-rise Heat Detector, legacy housing Data Sheet 85001-0243

Notification
Appliances
Intelligent Fixed Temperature Heat Detector
Includes a fixed-temperature sensor to detect heat from fire.
SIGA2-HFS Intelligent Fixed Temperature Heat Detector Data Sheet: 85001-0620
SIGA-HFS Intelligent Fixed Temperature Heat Detector, legacy housing Data Sheet 85001-0243

Duct Smoke Detectors

Hazardous Location
SuperDuct Detectors

Devices
Less than two inches deep, SuperDuct intelligent smoke detectors are ideal
Alarm relay output Remote
test station
for installation in ductwork, where space is always at a premium. Offering
the most advanced and most reliable performance in its class, SuperDuct
Duct smoke Return represents the perfect balance of practical design and advanced technology.
detector air
HVAC
unit SuperDuct detectors feature a unique design that speeds installation and
Duct smoke Supply simplifies maintenance. Removable dust filters, conformally coated circuit
detector air
boards, and optional water-resistant gaskets keep contaminants away
Alarm relay output
from components, ensuring years of trouble-free service. When cleaning
Remote
test station is required, the assemblies come apart easily and snap back together in
FACP
seconds.
Door Holders
& Relays

SIGA-SD Intelligent SuperDuct Detector Data Sheet: 85001-0584


SD-PH Protective housing for high humidity environments Data Sheet: 85001-0584
Sampling Tubes  SD-T8 (8”)  SD-T18 (18”)  SD-T24 (24”)  SD-T36 (36”)
 SD-T42 (42”)  SD-T60 (60”)  SD-T78 (78”)  SD-T120 (120”)
Remote Test Stations  SD-TRM (magnetic)  SD-TRM (keyed)  SIGA-LED (Remote alarm LED)
Accessories  SD-GSK (cover gasket kit)  SD-MAG (Test magnet kit)
 SD-VTK (Air velocity test kit, stoppers only)  SIGA-SDPCB (PCB/Signature sensor kit)

13
iO Series
SUBMIT
Intelligent Initiating Devices

 
Intelligent Control




   Detector Bases AB4GT AB4GT
iO Series


Listed 24
V EOL
3
AUX_RISER + Supervising
AUX_RISER -
Equipment

Audible (Sounder) Bases CO system wiring


TCDR for detector
Signature Series Sounder Bases add an audible output operation of bases
function to compatible detectors. The Signature Series SLC +

AB4GT sounder base, when used with the SIGA-TCDR SLC -

Temporal Pattern Generator, is compatible with any Signature Series detector, and is field-configurable
for: CO or non-CO detectors; output tone (steady or temporal); and, for output volume (low or high dBA).
The SIGA-AB4G is compatible with the SIGA-PS detectors only.
Initiating
Devices

SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors Data Sheet: 85001-0623
SIGA-TCDR Temporal Pattern Generator for SIGA-AB4GT Data Sheet: 85001-0623
SIGA-AB4G Audible (Sounder) Base for SIGA-PS Detectors Only Data Sheet: 85001-0581
AB4G-SB Surface Box for Audible Bases Data Sheet: 85001-0623

Standard Detector Bases


Standard detector bases provide roomside wiring terminals. They mount to
North American one-gang box, 3½ or 4-inch octagon boxes, or 4-inch square
electric box. Bases for 4-inch square boxes include the SIGA-TS4 Trim Skirt to
conceal the electric box and provide a finished appearance.

 SIGA-SB  SIGA-SB4 (with trim skirt) Standard Detector Base Data Sheet: 85001-0245

Isolator Detector Base


Isolator detector bases provide room-side wiring terminals and includes a built-in
line fault isolator. Models with integral switches allow the detector to be removed
from its base without causing the isolator to operate. Mounts to North American
one-gang box, 3½ or 4-inch octagon boxes, or 4-inch square electrical boxes.
Bases for 4-inch square boxes include the SIGA-TS4 Trim Skirt to conceal the
electrical box and provide a finished appearance.

 SIGA-IB  SIGA-IB4 (with trim skirt) Isolator Detector Base Data Sheet: 85001-0245

Relay Detector Base


This base includes a relay. Normally-open or closed operation is selected during
installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay’s
position is supervised to avoid accidentally jarring it out of position. The relay
base does not support the SIGA-LED remote LED. It mounts to North Ameri-
can one-gang boxes, 3½ or 4-inch octagon boxes, or 4-inch square electrical
boxes. Bases for 4-inch square boxes include the SIGA-TS4 Trim Skirt to conceal
the electrical box and provide a finished appearance.

 SIGA-RB  SIGA-RB4 (with trim skirt) Relay Detector Base Data Sheet: 85001-0245

14
iO Series Intelligent Initiating Devices

SUBMIT

 
Detector Accessories AUX_RISER_IN +

1
AUX_RISER_OUT +
A
2



  

SIGA-TCDR Temporal Pattern Generator From previous device To next device

SLC_IN + SLC_OUT +

The SIGA-TCDR Temporal Pattern Generator is an addressable


device that generates sound patterns for carbon monoxide (CO) and fire signals for the
AB4GT sounder base. The control panel sends synchronization and channel commands to
the SIGA-TCDR; the channel selection determines the pattern.

Initiating
Devices
SIGA-TCDR Temporal Pattern Generator for AB4GT Sounder Base Data Sheet: 85001-0623

Detector Mounting Plate


The SIGA-DMP Detector Mounting Plate is a 7-inch (178mm) square mounting plate designed
to provide convenient mounting of Signature Series intelligent smoke detectors in raised floor
or plenum applications. The detector mounting plate may also be installed in low velocity
ducts that have a maximum width of up to 36-inches (915mm) and a maximum height of up
to 36-inches (915mm).

SIGA-DMP Detector Mounting Plate Data Sheet: 85001-0255

Notification
Appliances
Remote LED
The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base. It features a North
American size one-gang plastic faceplate with a white finish and red alarm LED.

SIGA-LED Remote Alarm LED Data Sheet: 85001-0245

Hazardous Location
Trim Skirt  
Use the SIGA-TS Trim Skirt to give Signature detectors a finished look and hide surface

Devices
imperfections around the detector’s base. Supplied with all four-inch detector bases, the
SIGA-TS4 can also be ordered separately. Use the black model with SIGA-IPHSB.

SIGA-TS Detector Trim Skirt (white) Data Sheet: 85001-0245


SIGA-TSB Detector Trim Skirt (black) Data Sheet: 85001-0245
SIGA-TS4 Detector Trim Skirt (white) – for 4-inch box Data Sheet: 85001-0245

Detector Guard
Door Holders

Constructed of sturdy 16-guage steel, the SIGA-DG Smoke Detector Guard is designed
& Relays

SIGA-PS smoke detectors from damage or tampering. The advanced louver system allows
smoke detectors to be installed at their listed spacing and has no effect on operating sensitivity.

SIGA-DG Smoke Detector Guard Data Sheet: 85001-0359


SIGA-DGSB Detector Guard Surface Mount Accessory Data Sheet: 85001-0359

15
iO Series
SUBMIT
Intelligent Initiating Devices

 
Intelligent Control




   Signature Series
iO Series

Input/Output Modules

Signature Series input/output modules are extremely flexible and


powerful devices that gather analog information from the slave devices
connected to them and convert this data into digital signals. They are Plug-in UIOs
with motherboard
available in models that mount in standard one- or two-gang electrical
boxes, as well as versions that plug into UIO motherboards.
Initiating

Standard two-gang mount


Devices

The actual function of each module is determined by its installer-


selected personality code. This is downloaded to the module from the
Signature Loop Controller during system configuration. Because they are intelligent devices, all decisions are made
at the module. This allows lower communication speed but very fast control panel response time and less sensitivity
to line noise and loop wiring properties. As a result, twisted or shielded wire is not required.

Application Module
Waterflow Switches Waterflow/Tamper Module
Class A indicating and initiating circuits, Universal Class A/B
two-wire smoke detectors Module
Class B Input Module
Signature Series intelligent
Class B Initiating Circuits:
Monitor Module
input/output modules feature
Door Closers, Fans, Dampers multiple user-set personality
Control Relay Module
Telephone Power and Audible/Visual Signal
codes that define the module’s
Signal Module behavior.
Power Selector, Strobe Synchronization
Sounder Base power Reversal Relay Module
Fire Suppression Releasing Module
Fault detection Isolator Module

UIO Motherboard

Module mounting and installation options


Plug-in (UIO)
Signature Series input/output modules are available in models that Module

feature two mounting options: standard mount and plug-in.


Standard mount models are installed to North American two-gang Cabinet or electrical enclosure
or one-gang electrical boxes, making them ideal for locations where
Plug-in UIO
only one module is required. Separate I/O and data loop connections
are made to each module. ALA
FIRE DULE
RM

MO

Plug-in UIO modules mount to UIO moth-


erboards. Two- and six-module UIO Standard mount
(one- or two-gang)
motherboards are available, mak-
ing them ideal for installations
where more than one module is required. Motherboards can
accommodate individual risers for each on-board module,
or shared risers in any combination with their UIO
modules. All wiring connections are made
to terminal blocks on the motherboard.
UIO assemblies may be mounted in either
cabinets, or standard electrical enclosures.

16
iO Series Intelligent Initiating Devices

SUBMIT

 



  

Universal Class A/B Module


The Universal Class A/B Module is used to connect initiating, appliance, or two-wire smoke
SIGA-UM
circuits in either Class A or Class B configurations. The plug-in version can also be used as a
Class A dry contact initiating device circuit. The actual function of this module is determined
by the “personality code” selected by the installer. Up to fifteen personalities are available.

Initiating
SIGA-MAB

Devices
SIGA-UM Universal Class A/B Module (Two-gang standard mount) Data Sheet: 85001-0275
SIGA-MAB Universal Class A/B UIO (Plug-in) Module Data Sheet: 85001-0275

Class B Input Module


The Class B Input Module is used to connect Class B normally-open Alarm, Supervisory, or
SIGA-CT1/CT2
Monitor type dry contact initiating device circuits. The standard-mount version is available with
either one or two input connections. The plug-in version accepts two input connections. The

Notification
actual function of this module is determined by the “personality code” selected by the installer.

Appliances
A total of four personalities are available. SIGA-MCT2

SIGA-CT1 Single Input Module (One-gang standard mount) Data Sheet: 85001-0241
SIGA-CT1HT Single Input Module, high temperature rating (One-gang standard mount) Data Sheet: 85001-0241
SIGA-CT2 Dual Input Module (One-gang standard mount) Data Sheet: 85001-0241
SIGA-MCT2 Dual Input UIO (Plug-in) Module Data Sheet: 85001-0241

Hazardous Location
Synchronization Output Module
The Synchronization Output Module is an intelligent device that connects a supervised output

Devices
circuit to a 24 Vdc riser. The output wiring is monitored for open circuits and short circuits.
A short circuit will cause the fire alarm control panel to inhibit the activation of the audible/
visual signal circuit so the riser is not connected to the wiring fault. Upon command from the
Signature loop controller, the Auto-Sync Output Module connects the output circuit to the
riser input. The output circuit operates polarized audible and visual appliances that have an
adjustable resynchronizing feature.
SIGA-CC1S Synchronization Output Module (One-gang standard mount) Data Sheet: 85001-0543
SIGA-MCC1S Synchronization Output UIO (Plug-in) Module Data Sheet: 85001-0543
Door Holders
& Relays

17
iO Series
SUBMIT
Intelligent Initiating Devices

 
Intelligent Control




   Signature Series
iO Series

Input/Output Modules

Signal Module
The Signal Module is used to connect, upon command from the loop controller, supervised
Class B signal or telephone circuits to their respective power inputs. Models are available with
one or two power inputs. These may be either polarized 24 Vdc to operate audible and visual
signal appliances, or 25 and 70Vrms to operate audio evacuation speakers and firefighter’s
Initiating
Devices

telephones. The actual function of this module is determined by the “personality code” selected
by the installer. A total of three personalities are available.
SIGA-CC1 Single Input Signal Module (Two-gang standard mount) Data Sheet: 85001-0237
SIGA-MCC1 Single Input Signal UIO (Plug-in) Module Data Sheet: 85001-0237
SIGA-CC2 Dual Input Signal Module (Two-gang standard mount) Data Sheet: 85001-0237
SIGA-MCC2 Dual Input Signal UIO (Plug-in) Module Data Sheet: 85001-0237
SIGA-CC2A Dual Input Signal Module with Class A Operation (Two-gang mount) Data Sheet: 85001-0609
SIGA-MCC2A Dual Input Signal UIO with Class A Operation (Plug-in) Module Data Sheet: 85001-0609

Control Relay Module


The Control Relay Module provides a Form C dry relay contact to control external appliances
such as door closers, fans, dampers etc. This device does not provide supervision of the
state of the relay contact. Instead, the on-board microprocessor ensures that the relay is in
the proper ON/OFF state. Upon command from the loop controller, the relay activates the
normally open or normally-closed contact. This module supports only one personality: no user
configuration is required.
SIGA-CR Control Relay Module (One-gang standard mount) Data Sheet: 85001-0239
SIGA-MCR Control Relay UIO (Plug-in) Module Data Sheet: 85001-0239

Polarity Reversal Relay Module


The Polarity Reversal Relay Module provides a Form C dry relay contact to power and activate a
series of SIGA-AB4 Audible Sounder Bases. Upon command from the Signature loop controller,
the SIGA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on
the data loop. This module supports only one personality: no user configuration is required.

SIGA-CRR Polarity Reversal Relay Module (One-gang standard mount) Data Sheet: 85001-0239
SIGA-MCRR Polarity Reversal Relay UIO (Plug-in) Module Data Sheet: 85001-0239

Riser Monitor Module


The SIGA-RM1 Riser Monitor Module is an intelligent device that monitors the integrity of 24
Vdc, 25 Vac, and 70 Vac circuits, as well as telephone riser signals. Upon the loss of a signal,
the Riser Monitor Module causes the fire alarm control panel to indicate an alert status. Per-
sonality codes downloaded to the Riser Monitor Module during system configuration determine
its function.

SIGA-RM1 Riser Monitor Module (One-gang standard mount) Data Sheet: 85001-0535
SIGA-MRM1 Riser UIO (Plug-in) Module Data Sheet: 85001-0535

18
iO Series Intelligent Initiating Devices

SUBMIT

 



  

Input/Output Module
The Input/Output Module is an intelligent device that provides the following
modes of operation:
•    Output with monitor input

Initiating
•   Input/programmable output

Devices
•   Input/direct output
SIGA-IO Input/Output Module (One-gang standard mount) Data Sheet: 85001-0533
SIGA-MIO Input/Output UIO (Plug-in) Module Data Sheet: 85001-0533

Waterflow/Tamper Module
The SIGA-WTM Waterflow/Tamper Module is a two circuit intelligent module. Circuit 1 is for Class
B normally-open waterflow alarm switches. When the input contact is closed for approximately 16
seconds, an “alarm” signal is sent to the loop controller. Circuit 2 is for Class B normally open dry
contact supervisory and tamper switches. When the input contact is closed, an “active” signal is

Notification
Appliances
sent to the loop controller. Conditions on both circuits are latched at the module.
SIGA-WTM Waterflow/Tamper Module (One-gang standard mount) Data Sheet: 85001-0297

Isolator Module
The SIGA-IM Isolator Module is an intelligent device that allows part of the Signature data loop
to continue operating in the event of a short circuit. The module can be wired into a Class
A data loop at any point. A maximum of 64 isolator modules can be installed on one circuit.
If a fault occurs, the isolator cuts power to all devices beyond the isolator on the loop. Once

Hazardous Location
activated, the line fault isolator continuously checks the faulted side of the loop to determine
if the short still exists. When the fault is cleared, the module automatically restores the entire
data loop to its normal condition.

Devices
SIGA-IM Fault Isolator Module (Two-gang standard mount) Data Sheet: 85001-0271

Monitor Module
The SIGA-MM1 is a single-circuit intelligent module that includes a Class B normally-open dry
contact. This is used for monitoring input from devices such as fans, dampers, and doors.
When the input contact is closed, an “active” signal is sent to the loop controller. The active
condition is not latched at the module.
SIGA-MM1 Monitor Module (One-gang standard mount) Data Sheet: 85001-0297
Door Holders
& Relays

19
iO Series
SUBMIT
Intelligent Initiating Devices

 
Intelligent Control




   Signature Series
iO Series

Input/Output Modules

Universal Input/Output (UIO) Motherboards


Signature Series Universal Input/Output Module Motherboards provide mounting
and wiring terminations for up to six Signature Series plug-in UIO (SIGA-“M” se-
ries) modules. UIO motherboards snap into a rigid extruded track (included) with
mounting pads for convenient mounting into a variety of equipment enclosures. UIO
Initiating
Devices

modules plug into the board and are held securely in place with captive machine
screws. All field wiring connects to terminal blocks on the motherboard, which
I O 6R permits rapid removal and replacement of modules for troubleshooting.
U
The SIGA-UIO2R provides mounting and wiring terminations for up to two UIO
modules, and the SIGA-UIO6R provides mounting and wiring terminations for up
to six UIO modules. Both motherboards feature a riser #1 input and a riser #2 input
2R
UIO bus. Jumpers on riser #1 input (between modules), facilitate sharing a single riser
among more than one module. This significantly reduces wiring requirements. Re-
moving the jumpers provides Module Input/Output Wiring

separate riser inputs to each adjacent module. Riser #2 input is


fixed to each module position and cannot be split.
Data In
The SIGA-UIO6 provides mounting and wiring
terminations for up to six UIO modules. This moth-
Signature
Data
Circuit
erboard provides two riser inputs that are common Riser 2 Input
common to
to all modules.
Data Out
all SIGA-UIO
Modules

UIO motherboards mount inside the MFC-A cabinet Jumpers Connect


Riser Input #1
or other suitable UL-listed electrical enclosure. Each Between Modules

MFC-A will hold one UIO2R motherboard or one Individual Riser 1 Input to each SIGA-UIO module

UIO6 or UIO6R motherboard complete with their


full complement of modules.

SIGA-UIO2R Universal Input/Output Module Board with Riser Inputs — 2 Module Positions Data Sheet: 85001-0365
SIGA-UIO6R Universal Input/Output Module Board with Riser Inputs — 6 Module Positions Data Sheet: 85001-0365
SIGA-UIO6 Universal Input/Output Module Board — 6 Module Positions Data Sheet: 85001-0365

Related Equipment
MFC-A Multi-function Cabinet (for UIO and Releasing modules)
27193-11 Surface Mount Box - Red, One-gang
27193-16 Surface Mount Box - White, One-gang
27193-21 Surface Mount Box - Red, Two-gang
27193-26 Surface Mount Box - White, Two-gang
235196P Bi-polar Transient Protector (use with all Signal Modules)
SIGA-MP1 Signature Module Mounting Plate, 1 footprint
SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint
SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint

20
iO Series Intelligent Initiating Devices

SUBMIT

 



  

Releasing Module
The Signature Series Releasing Module (SIGA-REL) is an analog addressable
module that works with fire suppression systems designed to release extinguish-
ing gas such as Halon. Its primary function is the control of sprinkler pre-action
routines and the initiation of suppression system deluge functions. The module

Initiating
Devices
is easily configured in the field and offers a wide range of options that prevent
the unnecessary release of extinguishing agent.
The SIGA-REL is a network component consisting of:
• Two supervised release circuits
• Two supervised pre-release circuits
• One supervised manual
release input circuit Abort
First alarm output

• One supervised abort cir- Manual Release Form C 3 A @24 Vdc

cuit for N/O abort switch TB6


_
• One first alarm output SW1-SW8
TB3 TB2 +
_
24 Vdc in

relay (Form C Contact)


24 Vdc out
TB1 +
+ SIGA-REL
Signature data in DS1
_

Notification
Appliances
The releasing module includes a built-in timer that inhibits the deluge Signature data out +
_
DS2

function during the pre-action routine. One of four pre-action routines, DS4 DS5 DS3

may be selected by means of dip-switches on the module. The DS6 DS7

duration of automatic and manual time delays, as well as the abort


TB4 _
_ TB5
_ _
+ + + +

time settings are also selectable with dip-switches. The SIGA-REL


mounts inside an MFC-A cabinet or other suitable UL-listed electrical Pre-release CCT2 (steady)

enclosure. Each MFC-A will hold one SIGA-REL. Pre-release CCT1 (pulsed 15/60)

RELA-EOL RELA-EOL

Available releasing module accessories include dedicated pull sta- 1


2
3
1
2
3

tions, abort switches and service switches. Together with the SIGA- 4 4

REL, they comprise a complete fire suppression package.


Release CCT1 Release CCT2

Hazardous Location
SIGA-REL Analog addressable releasing module Data Sheet: 85001-0531
RELA-ABT Abort station Data Sheet: 85001-0531

Devices
RELA-SRV Service disconnect station Data Sheet: 85001-0531
276A-REL Manual releasing station (single-action) Data Sheet: 85001-0531
278A-REL Manual releasing station (double-action) Data Sheet: 85001-0531
RELA-EOL Polarized end-of-line relay Data Sheet: 85001-0531
Door Holders
& Relays

21
iO Series
SUBMIT
Intelligent Initiating Devices
NORM
AL

LIF
T

 
Intelligent Control




   Signature Series
iO Series

Manual Pull Stations REAR VIEW

TB2

Single Action Pull Stations 8 7

SIGA-270 series manual pull stations are made from Red LED
(Alarm/Active)
4 3 2 1
Green LED
(Normal)

die-cast zinc and finished with red epoxy powder- TB1

coat paint. With positive pull-lever operation, one


pull on the station handle breaks the rod and turns
in a positive alarm. Where two-stage operation is re-
quired, SIGA-270P pre-signal models are equipped DATA IN (+) DATA OUT (+)

with a general alarm (GA) keyswitch. DATA IN (-)

From Signature Controller


DATA OUT (-)
To Next Device
Initiating
Devices

or Previous Device

SIGA-270 One Stage Fire Alarm Station, English Markings Data Sheet: 85001-0279
SIGA-270P Two Stage (Pre-signal) Fire Alarm Station, English Markings Data Sheet: 85001-0279
276-K2 GA Key — for pre-signal station Data Sheet: 85001-0279
270-GLR 20 Break-rods — for SIGA-270 series Data Sheet: 85001-0279
276B-RSB Surface Mount Box, Red — for SIGA-270 series Data Sheet: 85001-0279

REAR VIEW

Double Action Pull Stations TB2

8 7

The double action, single stage SIGA-278 station is a


contemporary style manual station made from durable
Red LED Green LED
(Alarm/Active) (Normal)
4 3 2 1

red LEXAN. To initiate an alarm, first lift the upper door, TB1

then pull the alarm handle.

DATA IN (+) DATA OUT (+)

DATA IN (-) DATA OUT (-)

From Signature Controller To Next Device


or Previous Device

SIGA-278 Double Action (One Stage) Fire Alarm Station, English Markings Data Sheet: 85001-0279
276B-RSB Surface Mount Box, Red — for SIGA-278 series Data Sheet: 85001-0279
276-GLR 20 Break-rods — for SIGA-278 series Data Sheet: 85001-0279

Manual Station Relocator


The Manual Station Relocator is designed to lower the height of a fire alarm pull station to meet ADA
requirements. Most existing pull stations are mounted 60 inches (1524mm) or higher above the floor.
The Relocator lowers the height to 48 inches (1220mm) without the need for pulling new wires or
moving the existing electrical box.
RR-32RL Pull Station Relocator Data Sheet: 85001-0351

Stopper II
This unique device helps prevent false alarms without restricting legitimate ones. It consists of a tamper-
proof clear LEXAN polycarbonate shield and frame that fits easily over manual pull stations. When lifted,
it sounds a piercing warning horn.
  STI-1100 (Flush)   STI-1130 (Surface) Stopper II with Horn Data Sheet: 85001-0491
  STI-1200 (Flush)   STI-1230 (Surface) Stopper II without Horn Data Sheet: 85001-0491
  STI-3100 (2" Spacer)   STI-3004 (Conduit Insert) Spacers Data Sheet: 85001-0491
  STI-3002 (Gasket)   STI-3003 (Conduit Gasket) Weatherproofing Data Sheet: 85001-0491

22
iO Series N o t i fi c a t i o n A p p l i a n c e s

Wall Strobes, Horns & Chimes p. 25

Wall Speakers and Speaker-strobes p. 26

LED Strobes, Horn-Strobes p. 26

Ceiling Speakers, Horns, and Strobes p. 27

Low Frequency Horns and Strobes p. 27

Outdoor Speakers and Speaker-Strobes p. 28

Outdoor Horns and Horn-Strobes p. 29

Notification
Harsh Environment Signals p. 30

Genesis Signal Master p. 31

Audible Signals p. 31

Appliances

Accessories p. 33
Audio Notification System p. 32

iO Series notification appliances are high-performance devices finely tuned


Class B wiring to deliver maximum
Class B wiring
output in exchange for the lowest possible current draw. Covering theNAC1
entire
- spectrum of life safety
+ +
NAC1 -
NAC1+ + +
applications, these devices are durable, dependable, and virtually maintenance-free.
NAC1+ And
- they -
EOLR
NAC2 - - -
+ + EOLR
support a wide range of mounting options that make them ideal for new construction
NAC2
NAC2+
-
+and retrofit+
NAC2+ - -
applications alike. TB2 - -
TB2

Class B wiring
iO500 control panels come equipped with four notification Class B wiring

Notification
NAC1 -

Appliances
appliance circuits that can be wired to provide four Class NAC1 -
+ +
NAC1+ + +
NAC1+
- -
B NACs or two Class A NACs. The iO64 comes with two NAC2 - - - EOLR
NAC2 -
+ + EOLR
Class B NACs. These may be configured for Class A op- NAC2+ +- +-
NAC2+
TB2 - -
eration with the optional SA-CLA Class A Module installed. TB2 NAC3 -
NAC3 -
+ +
iO Series NACs may be individually configured for continu- NAC3+ + +
NAC3+ - - EOLR
ous, temporal, synchronized, and coded output.
NAC4 -
NAC4 -
+- +- EOLR
NAC4+ + +
NAC4+ - -
iO Series NACs are configurable to fully support the advanced - -

Hazardous Location
TB6
TB6
signaling technology of Edwards Genesis and Enhanced
Class A wiring
Class A wiring-
Integrity notification appliances. These devices offer precision

Devices
NAC1
NAC1 -
+ +
synchronization of strobes to UL 1971 standards. For Genesis NAC1+ + +
NAC1+ - -
NAC2 - - -
devices, enabling this feature allows connected horns to be NAC2 - + +
NAC2+ +
- -+
silenced while strobes on the same two-wire circuit continue TB2
NAC2+
- -
TB2 -
to flash until the panel is reset. -
+
+
-
-
+
+
TB6
Door Holders

TB6
& Relays

23
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s

 
Genesis Visual
Intelligent Control




  
iO Series

& Audible Signals


A complete line engineered to The award-winning Genesis line of products represents
excellence in fire alarm notification with looks, features, and
deliver innovative features and performance benefits designed with your project in mind.
superb output. Wall strobes, horns, and chimes about the size of a deck
of playing cards offer a discreet alternative to bulky devices,
Initiating
Devices

while speakers and ceiling models with clean modern lines


blend inconspicuously with their surroundings.
Wall Strobes, Horns, Chimes,
p. 25
Signaling on-demand
Though designed for discretion, Genesis signals are also
engineered to command attention. Wall-penetrating high
dB output and patented FullLight strobe technology im-
Wall Speakers and Speaker-strobes,
p. 26 merse the protected area with levels of light and sound
that simply can’t be ignored – all in exchange for the low-
Notification
Appliances

est current demands of any device in their class.

Genesis brings on-demand signaling to every applica-


LED Strobes and Horn-Strobes, p. 26 tion with an unparalleled range of field-configurable
options: horns and chimes with high/low dB output
settings; speakers with multiple wattage tap selections;
and strobes with selectable candela output and flash
Ceiling Speakers, Horns,
Strobes, p. 27 rate – options that put you in the driver’s seat when time
is short, budgets slim, and manpower at a premium. It
also means fewer parts to stock, less inventory to worry
about, and the flexibility to meet changing demands – on
Low Frequency Horns and Horn- the fly – without having to reinstall equipment or order
Strobes, p. 27
more parts!

Application flexibility
Whether you’re designing for a new landmark structure,
or simply retrofitting a local strip mall, competitively-
Outdoor Speakers, Speaker-Strobes,
p. 28 priced Genesis signals bring value, good looks, and
installation flexibility to every application. Contact Ed-
wards today to learn how your signal solutions can be
the model of discretion.

Outdoor Horns, Horn-Strobes, p. 29

24
iO Series N o t i fi c a t i o n A p p l i a n c e s

SUBMIT

 
Genesis Series Wall Models



  
Strobes,
Horns & Chimes
Genesis signals feature textured housings in architecturally neutral white or
traditional fire red. An ingenious iconographic symbol indicates the purpose
of the device. This universal symbol is code-compliant and is easily recog-
nized by all building occupants regardless of what language they speak.
models with “FIRE” and “ALERT” markings are also available.

Genesis strobes offer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the
device. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent
unauthorized tampering. (Data Sheet 85001-0573)
White housing White housing Red housing Red housing Fire Alarm Appliances
no marking with “FIRE” no marking with “FIRE” (with “Running Man” icon)
  G1-VM   G1F-VM   G1R-VM   G1RF-VM Strobe only (15/30/75/110 cd)
  G1F-V1575   G1RF-V1575 Strobe only (15/75 cd¹), 24 V

Genesis Horns and Horn-strobes reach output levels as high as 99 dB and features a unique multiple frequency tone that

Notification
Appliances
results in excellent wall penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-
coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB.
(Data Sheet 85001-0573)
White housing White housing Red housing Red housing Fire Alarm Appliances
no marking with “FIRE” no marking with “FIRE” (with “Running Man” icon)
  G1-HD   G1F-HD   G1R-HD   G1RF-HD Horn only (high/low dB)
  G1-HDVM   G1F-HDVM   G1R-HDVM   G1RF-HDVM Horn-strobe (15/30/75/110, high/low dB)
  G1F-HDV1575   G1RF-HDV1575 Horn-strobe (15/75 cd¹, high/low dB), 24 V
  G1-P   G1F-P   G1R-P   G1RF-P Steady horn (not compatible with Signal Master)

Hazardous Location
Genesis chimes and chime-strobes produce a pleasing mellow tone. When steady (non-stroked) voltage is applied, the
chime automatically pulses at 60 strokes per minute, or may be field-configured for temporal output. When installed with a
GIM Signal Master Module, the chime may also be field-configured for coded operation, which enables the chime output

Devices
to match the rate that voltage is applied to the circuit. Chimes may be set for low dB output with a jumper cut that reduces
sound output by about 5 dB. (Data Sheet 85001-0574)
White housing Red housing Chimes and Chime-strobes
  G1-CVM   G1R-CVM Chime-strobe (15/30/75/110, high/low dB)
  G1-C   G1R-C Chime only (high/low dB)

Trim plates for wall horns, chimes, and strobes are ideal for covering openings left behind during retrofits.
White plate White plate Red plate Red plate White plateFire Trim Plates
no marking with “FIRE” no “FIRE” with “FIRE” with “ALERT”
Door Holders

  G1T   G1T-FIRE   G1RT   G1RT-FIRE   G1WT-ALERT Trim plate for 2-gang or 4” boxes
& Relays

¹ 15/75 cd models provide fixed output. The 15 cd output component complies with UL1971. The 75 cd output component complies with UL 1638.

25
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s

 
Intelligent Control




   Genesis Series Wall Models

Speakers,
iO Series

Speaker-strobes Use the Candela Switch and the To change strobe to


Genesis speakers include a DC blocking capacitor to allow electrical Wattage switch to set desired operation. (private mode) cut J

supervision of the audio distribution circuit. Models for 25 VRMS and 70


VRMS circuits are available. The mylar speaker with its sealed back con-
struction provides extra durability and improved audibility. ¼ W to 2 W
operation is selectable with a conveniently-located switch on the bottom
JP1

15

1
of the device. (Data Sheet 85001-0549)
Bottom View
Initiating

Speaker-strobes feature 15, 30, 75 or 110 candela output,


Devices

Candela switch Wattage switch

selectable with a conveniently-located switch on the bottom Candela and wattage settings remain clearly
of the device. visible even after final installation.

All speakers feature selectable ¼, ½, 1, or 2 watt operation. Multi-candela strobes feature selectable 15, 30, 75, or 110 cd output.

White housing White housing Red housing Red housing Fire Alarm Speakers
no marking with “FIRE” no marking with “FIRE” (with “Running Man” icon)
  G4-S2   G4F-S2   G4R-S2   G4RF-S2 25 V Speaker
  G4-S7   G4F-S7   G4R-S7   G4RF-S7 70 V Speaker
  G4-S2VM   G4F-S2VM   G4R-S2VM   G4RF-S2VM 25 V Speaker-strobe (15/30/75/110 cd settings)
  G4-S7VM   G4F-S7VM   G4R-S7VM   G4RF-S7VM 70 V Speaker-strobe (15/30/75/110 cd settings)
Notification
Appliances

  G4F-S7V1575   G4RF-S7V1575 70 V Speaker (15/75 cd)

Genesis Series Wall Models

LED Strobes, Horn-strobes


Genesis GL Series horns and LED strobes break the current draw barrier with innova-
tive technology that not only makes them inexpensive to install and operate, but also
allows them to maintain the sleek low-profile design that has made Genesis appliances
a favorite among facility owners, architects, and designers. Horn-Strobe models fea-
ture field-selectable 15, 30, 75, or 110 cd output settings. Horn-strobe and horn-only
appliances feature field-configurable high/low dB and temporal/steady audible output.
GL1RF-HD Horn-only, Red Housing, FIRE Marking Data Sheet 85001-0635
GL1RF-HDVMC Horn-Strobe, Red Housing, FIRE Marking Data Sheet 85001-0635
GL1RF-VMC Strobe-only, Red Housing, FIRE Marking Data Sheet 85001-0635
GL1RN-HD Horn-only, Red Housing, No Marking Data Sheet 85001-0635
GL1RN-HDVMC Horn-Strobe, Red Housing, No Marking Data Sheet 85001-0635
GL1RN-VMC Strobe-only, Red Housing, No Marking Data Sheet 85001-0635
GL1WF-HD Horn-only, White Housing, FIRE Marking Data Sheet 85001-0635
GL1WF-HDVMC Horn-Strobe, White Housing, FIRE Marking Data Sheet 85001-0635
GL1WF-VMC Strobe-only, White Housing, FIRE Marking Data Sheet 85001-0635
GL1WN-HD Horn-only, White Housing, No Marking Data Sheet 85001-0635
GL1WN-HDVMC Horn-Strobe, White Housing, No Marking Data Sheet 85001-0635
GL1WN-VMC Strobe-only, White Housing, No Marking Data Sheet 85001-0635

  GL1WN-TP (White)   GL1RN-TP (Red) Trim Plate for four-inch square boxes Data Sheet 85001-0635
  GL1WN-BB1G (White)   GL1RN-BB1G (Red) One-gang surface box for GL Series Data Sheet 85001-0635

26
iO Series N o t i fi c a t i o n A p p l i a n c e s

SUBMIT

 
Genesis Series Ceiling or Wall Models



  
Speakers,
Horns, Strobes
Select
The Genesis line of multi-candela and multi-wattage ceiling sig- 15/30/75/95 Select
nals feature all the hallmarks that have made Genesis products a and 95/115/150/177 ¼, ½, 1, or 2
candela output! watt operation!
big hit with designers, engineers, building owners, and installers
everywhere. These signals are 30 per cent slimmer than compa-
Ceiling Strobes Data Sheet 85001-0557
rable signals on the market. They are compatible with standard
Ceiling Horn-strobes Data Sheet 85001-0559
4-inch (10 cm) square electrical boxes and don’t require exten-
Ceiling Speaker-strobes Data Sheet 85001-0556
sion rings or trim plates. These signals are also listed for wall Ceiling Speakers Data Sheet 85001-0556
mount applications.

White housing White housing Red housing All fire alarm appliances come
no marking with “FIRE” with “FIRE” with the “Running Man” Icon
  GC-VM   GCF-VM   GCFR-VM Strobe, 15/30/75/110 (standard output) cd, selectable
  GC-VMH   GCF-VMH Strobe, 95/115/150/177 (high output) cd, selectable
  GC-HDVM   GCF-HDVM   GCFR-HDVM Horn-strobe, 15/30/75/110 (standard output) cd, selectable
  GC-HDVMH   GCF-HDVMH Horn-strobe, 95/115/150/177 (high output) cd, selectable
  GC-S2VM   GCF-S2VM Speaker-strobe, 25 V, 15/30/75/110 cd selectable
  GC-S2VMH   GCF-S2VMH Speaker-strobe, 25 V, 95/115/150/177 cd selectable

Notification
Appliances
  GC-S7VM   GCF-S7VM   GCFR-S7VM Speaker-strobe, 70 V, 15/30/75/110 cd selectable
  GC-S7VMH   GCF-S7VMH Speaker-strobe, 70 V, 95/115/150/177 cd selectable
  GC-S2   GCF-S2   GCFR-S2 Speaker, 25 V
  GC-S7   GCF-S7   GCFR-S7 Speaker, 70 V
All speakers feature selectable ¼, ½, 1, or 2 watt operation. All horns feature high or low dB output.
Multi-Candela Strobes feature 15, 30, 75, or 95 candela output. Multi High-Candela Strobes feature 95, 115, 150, or 177 candela output.

Genesis Series Wall Models

Hazardous Location
Low Frequency Horns & Strobes
Devices
G4LF Series notification appliances provide the benefits of Genesis life safety signals with
output suitable for sleeping areas and other applications requiring low frequency audible
tones. These high-performance appliances generate a crisp 520 Hz tone in the standard
3-3 temporal pattern. An optional setting configures the appliance for continuous audible
output — a critical feature for notification appliance circuits that are coded with a CDR-3
coder module. All G4LF appliances feature field-configurable high and low dB output set-
tings. Horn-Strobe models feature field-selectable 15, 30, or 75 cd output settings.

G4LFWN-HVM Horn-Strobe, 520 Hz, White Housing, No Marking, 15/30/75 cd Data Sheet 85001-0639
G4LFWF-HVM Horn-Strobe, 520 Hz, White Housing, FIRE Marking, 15/30/75 cd Data Sheet 85001-0639
Door Holders

G4LFRN-HVM Horn-Strobe, 520 Hz, Red Housing, No Marking, 15/30/75 cd Data Sheet 85001-0639
& Relays

G4LFRF-HVM Horn-Strobe, 520 Hz, Red Housing, FIRE Marking, 15/30/75 cd Data Sheet 85001-0639
G4LFWN-H Horn, 520 Hz, White Housing, No Marking Data Sheet 85001-0639
G4LFWF-H Horn, 520 Hz, White Housing, FIRE Marking Data Sheet 85001-0639
G4LFRN-H Horn, 520 Hz, Red Housing, No Marking Data Sheet 85001-0639
G4LFRF-H Horn, 520 Hz, Red Housing, FIRE Marking Data Sheet 85001-0639

27
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s

 
Intelligent Control




   Genesis Series
Genesis Series Wall or Ceiling Models
iO Series

Outdoor Speakers
and Speaker-Strobes
Genesis WG4 Series speakers and speaker-strobes are among the most
versatile emergency signals of their kind. NEMA 4X rated for indoor or
outdoor use, they are suitable for a wide range of wet and harsh environ-
ments with a listed operating temperature range of as low as -31°F to as
high as 151°F (-35°C to 66°C).
Initiating
Devices

Refer to Data Sheet 85001-0627 -- Genesis Outdoor Speakers and Strobes for details.

Field Configuration SPKR -


SPKR +
SPKR -
SPKR +
STROBE - STROBE -
Genesis WG4 speakers may be set 70- or 25-Volt STROBE + STROBE +
S3: Speaker
operation, and for ¼, ½, 1, or 2 watt operation. voltage
Strobe models feature four selectable light output
settings. Wattage and cd selections are changed
by removing the cover and simply sliding the
switches to the desired settings, which remain vis-
ible through a small window on the front of the de-
Notification
Appliances

S1:
vice after the cover is replaced. Genesis speaker- wattage
strobes may also be configured for temporal flash.
This battery-saving feature is intended for private S2: JP1: Strobe temporal
mode signaling only. To set the device for temporal Candela mode selection
flash, snip the jumper at JP1.

WG4RF-S WG4RF-SVMC WG4WF-S WG4WF-SVMC WG4RN-S WG4RN-SVMC WG4WN-S WG4WN-SVMC

White housing White housing Red housing Red housing Fire Alarm Speakers
no marking with “FIRE” no marking with “FIRE”
  WG4WN-S   WG4WF-S   WG4RN-S   WG4RF-S 25/70 V Speaker
  WG4WN-SVMC   WG4WF-SVMC   WG4RN-SVMC   WG4RF-SVMC 25/70 V Speaker-strobe (15/29/70/87 cd)
     WG4WF-SVMHC   WG4RN-SVMHC   WG4RF-SVMHC 25/70 V Speaker-strobe (102/123/147/161 cd)

Trim skirts
  WG4WTS (white)     WG4RTS (red) Surface Skirt for Genesis WG4 appliance family.

28
iO Series N o t i fi c a t i o n A p p l i a n c e s

SUBMIT

 
Genesis SeriesWall or Ceiling Models  


  
Outdoor Horns
and Horn-Strobes
Genesis WG4 Series horns and horn-strobes are among the most versatile emer-
gency signals of their kind. NEMA 4X rated for indoor or outdoor use, they are suit-
able for a wide range of wet and harsh environments with a listed operating tem-
perature range of as low as -31°F to as high as 151°F (-35°C to 66°C).
Refer to Data Sheet 85001-0628 -- Genesis Outdoor Horns and Strobes for details.
Signal In — Signal Out —

Signal In + Signal Out +


Field Configuration
Genesis WG4 strobes feature four selectable light output set-
tings. Cd selections are changed by removing the cover and
simply sliding the switches to the desired setting, which remains
visible through a small window on the front of the device after the
cover is replaced. Genesis Horn-strobes may also be
configured for high or low dB output and temporal flash. This
battery-saving feature is intended for private mode signaling only.

Notification
Appliances
—/+ designations indicate the signal polarity
required to activate the device.

WG4RF-H WG4RF-HVMC WG4WF-H WG4WF-HVMC WG4RN-H WG4RN-HVMC WG4WN-H WG4WN-HVMC

Light Output

Hazardous Location
Standard Candela Horn-strobes High Candela Horn-strobes
Strobe Switch Position Strobe Switch Position
Standard/rating Standard/rating
D C B A D C B A
UL 1971 Indoor 15 cd 29 cd 70 cd 87 cd UL 1971 Indoor 102cd 123cd 147cd 161cd

Devices
UL 1638 Outdoor @ -35°C 6 cd 12 cd 28 cd 35 cd UL 1638 Outdoor @ -35°C 41cd 50 cd 60 cd 65 cd
CAN/ULC-S526 Outdoor @ -40°C 1 cd 3 cd 8 cd 10 cd CAN/ULC-S526 Outdoor @ -40°C 11 cd 14 cd 17 cd 18 cd

White housing White housing Red housing Red housing Outdoor Fire Alarm Appliances
no marking with “FIRE” no marking with “FIRE”
  WG4WN-H   WG4WF-H   WG4RN-H   WG4RF-H Horn Only
  WG4WN-HVMC   WG4WF-HVMC   WG4RN-HVMC   WG4RF-HVMC Horn-Strobe, standard cd output
  WG4WN-HVMHC   WG4WF-HVMHC   WG4RN-HVMHC   WG4RF-HVMHC Horn Only, high cd output
Door Holders
& Relays

WG4 Mounting Accessories


  WG4WTS (white)   WG4RTS (red) Surface Skirt for Genesis WG4 Appliances
  74347U (white)   449 (red) Surface mount box, outdoor rated
  WG4GSKT Genesis WG4 Full Body Mounting Gasket for Smooth Surfaces

29
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s

  Enhanced Integrity Series


Intelligent Control




   Harsh Environment
North American
2-gang electrical box
Mounting Plate
iO Series

Signals Housing
Surface Box (optional)

Single Captive Mounting Screw

All Enhanced Integrity devices are UL 1971 listed for both wall and ceiling orien- First Device

tation. Enhanced Integrity strobes meet the latest UL1971 synchronization re- - Horn/Strobe Horn/Strobe
To Fire Alarm
Control Panel H+ H+

quirements when used with the G1M Signal Master. Integrity devices are shipped Signal Circuit H-
S+
H-
S+
+
with wall mount style “FIRE” lens markings. Other lens markings are available.
S- S- To Next Device
or EOL Resistor
-
+

Re-Entrant Speakers and Speaker-Strobes


Initiating
Devices

Re-entrant speakers feature a sealed, high efficiency compression driver that’s both weatherproof and
vermin proof. This makes them ideal for public places and outdoor areas such as parking garages
and transport terminals. All Integrity speakers include a DC Blocking Capacitor that permits electrical
supervision of the audio distribution circuit. Models for 25Vrms and 70Vrms circuits are available.

Fire Alarm Appliances, clear lenses, Data Sheet 85001-0317


15/75 cd 30 cd 110 cd Speaker only
  757-7A-RS25   757-3A-RS25   757-8A-RS25   757-1A-R25 Speaker-strobe, 25 V, red housing
  757-7A-RS25W   757-3A-RS25W   757-8A-RS25W   757-1A-R25W Speaker-strobe, 25 V, white housing
  757-7A-RS70   757-3A-RS70   757-8A-RS70   757-1A-R70 Speaker-strobe, 70 V, red housing
Notification
Appliances

  757-7A-RS70W   757-3A-RS70W   757-8A-RS70W   757-1A-R70W Speaker-strobe, 70 V, white housing

ECS/MNS Appliances, amber lenses, Data Sheet 85001-0317


  757-7A-RS25WA (12/75 cd)     757-8A-RS25WA (88 cd)   Speaker-strobe, 25 V, white housing
  757-7A-RS70WA (12/75 cd)     757-8A-RS70WA (88 cd)   Speaker-strobe, 70 V, white housing

Temporal Horns and Horn-Strobes


During installation, the Horn is configured for steady or temporal tone signal. When temporal output
is selected, all Horns on a common two-wire circuit are self-synchronized. Integrity Series Horns
emit a low frequency “growling” tone that demands attention. Horns can be configured for either
high output (98 dBA) or low output (94 dBA); and are listed for outdoor use.
  757-1A-T (Red)   757-1A-TW (White) Temporal Horn Data Sheet: 85001-0341
  757-7A-T (Red)   757-7A-TW (White) Temporal Horn-Strobe, 15/75cd Data Sheet: 85001-0341
  757-4A-T (Red)   757-4A-TW (White) Temporal Horn-Strobe, 75cd Data Sheet: 85001-0341
  757-8A-T (Red)   757-8A-TW (White) Temporal Horn-Strobe, 110cd Data Sheet: 85001-0341

4” Square Box Mount Strobes


405 Series strobes are self-synchronized to flash at one fps across their full operating voltage range.
UL 1971 synchronization requirements are achieved when used with the G1M Signal Master. Strobes
must be connected to signal circuits that output a constant (not pulsed) voltage. A diode is used to
allow full signal circuit supervision. 405 Series strobes are suitable for outdoor use and installed to
a standard four-inch square electrical box.
  405-5A-T (Red)   405-5A-TW (White) Strobe - 15 cd Data Sheet: 85001-0305
  405-7A-T (Red)   405-7A-TW (White) Strobe - 15/75 Data Sheet: 85001-0305
  405-3A-T (Red)   405-3A-TW (White) Strobe - 30 cd Data Sheet: 85001-0305
  405-6A-T (Red)   405-6A-TW (White) Strobe - 60 cd Data Sheet: 85001-0305
  405-8A-T (Red)   405-8A-TW (White) Strobe - 110 cd Data Sheet: 85001-0305
  CS-405-7A-T (15/75 cd)   CS-405-8A-T (110 cd) Strobe - Weatherproof (red) Data Sheet: 85001-0305

30
iO Series N o t i fi c a t i o n A p p l i a n c e s

SUBMIT

Genesis Series Synchronization  


Signal Master  


  
The Signal Master is a simple-to-use accessory that adds enhanced features
to Genesis and Integrity strobes and Horn-Strobes. It is a dual-purpose
module that provides UL 1971 required precision synchronization for con-
nected Integrity and Genesis strobes, and independent control for connected
Genesis Horns over a single pair of wires. Two methods of Horn control are Snap-on Remote 1-gang
available: traditional Horn silence; or, normally-closed contact. Both methods (piggyback) model mount model
may be used to silence Horns without turning off strobes on the same circuit.
Two models are available. The Genesis “piggyback” model doesn’t require a
separate electrical box. It simply snaps to the back of the first G1 signal on
the circuit. The remote mount model mounts in a North American 2½ inch
(64 mm) deep one-gang box.
G1M Genesis Signal Master – Snap-on (piggyback) Data Sheet: 85001-0545
G1M-RM Genesis Signal Master – Remote 1-Gang Mount Data Sheet: 85001-0545

Audible Signals

Notification
Appliances
Fire Alarm Bells
Edwards fire alarm bells are of the underdome type with heavy-duty mechanisms. Gongs
are made of selected alloy steel to generate the loud, resonant tones. For weatherproof ap-
plication, optional surface weatherproof backboxes are available.
 323D-10AW (Grey)  323D-10AR (Red) 10-inch Single Stroke, Diode — 20-24Vdc Data Sheet: 85001-0333
439D-6AW (Grey)  439D-6AR (Red) 6-inch Vibrating, Diode — 20-24Vdc Data Sheet: 85001-0333
 439D-10AW (Grey)  439D-10AR (Red) 10-inch Vibrating, Diode — 20-24Vdc Data Sheet: 85001-0333

Hazardous Location
Multiple Tone Signal  

Devices
The 5530MD-24AW is a weatherproof heavy-duty industrial, tone-selectable, signaling de-
vice capable of producing volume-controlled, high-decibel tones. It uses a microprocessor
circuit to create 27 distinctive tones. A single tone may be selected by setting a miniature
dip switch within the unit.
5530MD-24AW 27-Tone Selectable Signal — 24Vdc Data Sheet: 85001-0415

Multi-purpose Loudspeaker
Door Holders

The HPSA15 loudspeaker is a high-efficiency double re-entrant loudspeaker that operates within a
nominal frequency response range of 400-14,000 Hz, and provides audible output of 120 dB (peak
& Relays

at one meter) at the rated power level. It includes a versatile, three-way, 25/70.7 V line transformer
that meets a variety of distributed system needs. The transformer is adjustable by means of a
convenient seven-position, watts/impedance selection switch.
HPSA15R2570 15-watt loudspeaker, red Data Sheet: 85001-0591
HPSA15G2570 15-watt loudspeaker, gray Data Sheet: 85001-0591

31
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s

 
  Audio Notification System
Intelligent Control





iO Series

Supervised - Power Limited Strobe Circuit


Fire NAC (Notification Appliance Circuit)
Alarm EOLR
Supervised - Power Limited
Control
NAC F F
Panel I I

Voice Evacuation Speaker Circuit R


E
R
E

Supervised - Power Limited EOLR


120
VAC Class “A” Speaker Circuit if required

Built-in Power
Transformer The ANS series of products from are high-performance audio notification
systems that provide voice evacuation capability that meet the Emergency
TB1 1 2 3 4 5 6 7 8

TB2
Voice Alarm requirements of NFPA 72 for UL listed fire alarm applica-
tions. ANS panels, which are available in 25, 50, or 100 Watt models,
11
1 TB3
10
2
9
3
8
4

include an amplifier, tone generator, digital message repeater (DMR), and


7
5
6
Initiating

6
Devices

5
7
Trouble 4

supervisory interface.
8
3
Normal 2
1

Alarm

System Status LEDs

These self-contained systems offer robust field-configurable features


and are supported by a wide range of accessory equipment that pro-
vides application flexibility and reliable performance for new and retrofit
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
installations alike. Expander panels and modules extend the range of
+ - + -
the ANS system to meet the needs of even the most demanding audio
12 V
Battery
12 V
Battery
applications, while accessory equipment such as zone switchers and
remote microphones offer the sophistication of high-end systems for a
relatively low cost.
Audio Notification Panels
Notification

Panels include DMR, temporal pattern, standard message, microphone, power supply and battery charger.
Appliances

ANS25MDG (Grey Cabinet) ANS25MDR (Red Cabinet) 25 Watt Audio Notification Panel. Data Sheet 85001-0587
ANS50MDG (Grey Cabinet) ANS50MDR (Red Cabinet) 50 Watt Audio Notification Panel. Data Sheet 85001-0587
ANS100MDG (Grey Cab) ANS100MDR (Red Cabinet) 100 Watt Audio Notification Panel. Data Sheet 85001-0587

Audio Expander Panels


Panels include power supply and battery charger. DMR and microphone ordered separately.
ANS25XG (Grey Cabinet) ANS25XR (Red Cabinet) 25 Watt Audio Expander Panel. Data Sheet 85001-0587
ANS50XG (Grey Cabinet) ANS50XR (Red Cabinet) 50 Watt Audio Expander Panel. Data Sheet 85001-0587
ANS100XG (Grey Cabinet) ANS100XR (Red Cabinet) 100 Watt Audio Expander Panel. Data Sheet 85001-0587

Audio Notification System Accessories


ANSAUX Audio Evacuation Accessory, Audio Matching Curcuit Data Sheet 85001-0587
ANSBKUP Audio Evacuation Accessory, Backup Amplifier Module Data Sheet 85001-0587
ANSBKUPA Audio Evacuation Accessory, Backup Amplifier Switching Module, A Data Sheet 85001-0587
ANSDMRALT Audio Evacuation Accessory, Alter Pre-Recorded DMR Message Data Sheet 85001-0587
ANSDMRCUSTOM Audio Evacuation Accessory, Custom Recorded Message Prom Data Sheet 85001-0587
ANSMIKE Audio Evacuation Accessory, Microphone Data Sheet 85001-0587
ANSREMG Audio Evacuation Accessory, Remote Microphone Cabinet, Gray Data Sheet 85001-0587
ANSREMR Audio Evacuation Accessory, Remote Microphone Cabinet, Red Data Sheet 85001-0587
ANSREMSUP Audio Evacuation Accessory, Super Card, Remote Microphone Data Sheet 85001-0587
ANST28180 Audio Evacuation Accessory, Power Transformer 50/100W Systems Data Sheet 85001-0587
ANST2885 Audio Evacuation Accessory, Power Transformer, 25W Systems Data Sheet 85001-0587
ANSZC2B Audio Evacuation Accessory, Zone Adapter Data Sheet 85001-0587
ANSZS2A Audio Evacuation Accessory, Zone Splitter, 2 Class A Zone Data Sheet 85001-0587
ANSZS4B Audio Evacuation Accessory, Zone Splitter, 4 Class B Zone Data Sheet 85001-0587
ANSZSC4A Audio Evacuation Accessory, Class A Converter Data Sheet 85001-0587
ANSZSR Audio Evacuation Accessory, Relay Card Data Sheet 85001-0587

32
iO Series N o t i fi c a t i o n A p p l i a n c e s

SUBMIT

 
Accessories  


  
Bell/Strobe Plate
The bell/strobe plate is ideal for renovation and retrofit projects, and new construction. It
is equipped with an Edwards self-synchronizing strobe and is designed to allow on-site
mounting of the 439 series Vibrating Bell, providing instant conversion to Bell/Strobe
audible/visual signal appliances. The strobe is designed for 20 to 24Vdc operation and
must be connected to signal circuits which output a constant (not pulsed) voltage. A
diode is used to allow full signal circuit supervision.

  403-5A-R (15 cd)    403-7A-R (15/75 cd)     403-3A-R (30 cd)    403-8A-R (110 cd)  Data Sheet: 85001-0441

Integrity Lens Marking Kits


Integrity strobes are shipped with wall mount style “FIRE” lens markings. Where ceiling mount, other languages or dif-
ferent lens markings are required, optional LKW and LKC series Lens Marking Kits are available. Lens marking sleeves
snap right over the strobe lens providing a quick, easy, change.
  LKW-1R (Wall orientation) “FIRE” (Red)
  LKW-1 (Wall orientation)   LKC-1 (Ceiling orientation) “FIRE”
  LKW-2 (Wall orientation)   LKC-2 (Ceiling orientation) “FEU”
  LKW-3 (Wall orientation)   LKC-3 (Ceiling orientation) “FIRE/FEU”

Notification
Appliances
  LKW-4 (Wall orientation)   LKC-4 (Ceiling orientation) “SMOKE”
  LKW-5 (Wall orientation)   LKC-5 (Ceiling orientation) “HALON”
  LKW-6 (Wall orientation)   LKC-6 (Ceiling orientation) “CO2”
  LKW-7 (Wall orientation)   LKC-7 (Ceiling orientation) “EMERGENCY”
  LKW-8 (Wall orientation)   LKC-8 (Ceiling orientation) “ALARM”
  LKW-9 (Wall orientation)   LKC-9 (Ceiling orientation) “FUEGO”
  LKW-10 (Wall orientation)   LKC-10 (Ceiling orientation) “ALERT”

Hazardous Location
Mounting Accessories

Devices
Integrity Temporal Horn, Horn/strobe Genesis Signals
  757A-SB Surface Box, Red, Indoor   27193-11 Horn-strobe Surface Box, Red, Indoor
  757A-SBW Surface Box, White, Indoor   27193-16 Horn-strobe Surface Box, White, Indoor
  757A-WB Weatherproof Box, Red, Surface   G4RB Speaker Surface Box, Red, Indoor
  757A-WBW Weatherproof Box, White, Surface   G4B Speaker Surface Box, White, Indoor
  G4ERB G4 Dual-strobe Format Surface box, Red
Integrity Speakers, Speaker/strobes   G4EWB G4 Dual-strobe Format Surface box, White
  960A-4SF Flush Box, Indoor
  757A-SB Surface Box, Red, Indoor Horn/siren Combination
  757A-SBW Surface Box, White, Indoor   349 Weatherproof Backbox

Integrity Re-entrant speakers, Speaker/strobes Fire Alarm Bells and CS-405 Series
  960A-4SF Flush Box, Indoor   449 Weatherproof Backbox
  757A-SB Surface Box, Red, Indoor
Door Holders

  757A-SBW Surface Box, White, Indoor


& Relays

  757A-WB Weatherproof Box, Red, Surface


  757A-WBW Weatherproof Box, White, Surface

Integrity Chimes, Chime/strobes


  757A-SB Surface Box, Red, Indoor
  757A-SBW Surface Box, White, Indoor
Genesis G4B Speaker
Surface Box

33
Notification Initiating iO Series
Appliances Devices Intelligent Control

34






SUBMIT
N o t i fi c a t i o n A p p l i a n c e s
iO Series
iO Series Hazardous Location Devices


Hazardous Location Devices

Initiating Devices p. 36

Hazardous
Notification Appliances p. 37

Location Devices
Edwards hazardous location devices provide reliable life safety protection and emergency signaling in areas where
atmospheres could become harsh or explosive. All hazardous location devices are UL rated under the full range of
classifications set out in the National Electrical Code.

The following classification definitions are an interpretive summary based on the 1996 edition of the National Elec-
trical Code (NEC, NFPA 70). Refer to the latest editions of NFPA 497M, NFPA 70 and the UL Hazardous Location
Equipment Directory for current and more detailed information. For more information on NEMA classifications, refer
to NEMA Standards Publication No. 250.

Hazardous Location Classifications

Classes Divisions
The Location Classes are broken down by the NFPA into
Class I - Hazardous Gases. Class I locations are areas in which flam- Divisions 1 and 2, defining different levels of risk. In general,
mable gases or vapors are or may be present in the air in quantities the risk of there being a hazardous presence of flammable/
sufficient to produce explosive or ignitable mixtures. combustible/ignitable materials is higher for Division 1 than
Typical Class I Hazardous Areas for Division 2. The specifics differ between the three classes
• Spray painting and finishing areas (I, II and III). Equipment suitable for Division 1 is also suitable
• Utility gas plants for Division 2 locations.
• Petroleum refining production plants
• Petroleum dispensing locations
• Dry cleaning facilities
Groups
Class I and II locations are divided by the NFPA into Group
• Dip tanks containing combustibles or flammable liquids
designations identifying specific gases, vapors and dusts by
• Plant facilities extracting solvents
characteristic similarities that relate to specific equipment
• Inhalation anesthetics areas
construction requirements. Class III locations are not divided
• Process facilities manufacturing pyroxylin type plastics
into separate group designations.
Class II - Hazardous Dusts. Class II locations represent areas that are
hazardous due to the presence of combustible dust. Class I Groups
Group A. Atmospheres containing acetylene.

Hazardous Location
Typical Class II Hazardous Areas
• Flour mills Group B. Atmospheres containing hydrogen, fuel and
• Feed mills combustible process gases containing more than 30 percent
• Grain elevators and grain handling facilities hydrogen by volume, or gases or vapors of equivalent hazard
• Aluminum manufacturing and storage areas such as butadiene, ethylene oxide, propylene oxide, and

Devices
• Magnesium manufacturing and storage areas acrolein.
• Coal preparation and handling facilities
• Starch manufacturing and storage areas Group C. Atmospheres such as ethyl ether, ethylene, or
• Confectionery plants other gases or vapors of equivalent hazard.
• Pulverizer sugar and cocoa manufacturing, and storage plants
Group D. Atmospheres containing acetone, ammonia,
• Spice grinding and storage plants
benzene, butane, cyclopropane, ethanol, gasoline, hexane,
Class III - Hazardous Fibers. Class III locations have easily ignitable methanol, methane, natural gas, naphtha (petroleum), pro-
fibers or flyings present, but not likely to be suspended in air in quantities pane, or gases or vapors of equivalent hazard.
sufficient to produce ignitable mixtures in the atmosphere.
Class II Groups
Typical Class III Hazardous Areas
Group E. Atmospheres containing combustible metal dusts,
• Textile mills
including aluminum, magnesium, and their commercial
• Woodworking plants*
alloys, or other combustible dusts whose particle size, abra-
Door Holders

• Furniture manufacturers*
siveness and conductivity present similar hazards in the use
• Cotton gins
& Relays

of electrical equipment.
• Cotton seed milling plants
• Flax plants Group F. Atmospheres containing combustible carbona-
• Carpet manufacturers ceous dusts, including carbon black, charcoal, coal, or dusts
that have been sensitized by other materials so that they
* Except if wood flour (dust), which is Class II Group G, is present
present an explosion hazard.

Group G. Atmospheres containing combustible dusts not


included in Group E or F, including flour, grain, wood, plastic,
and chemicals.

35
iO Series
SUBMIT
Hazardous Location Devices

 
  Initiating Devices
Intelligent Control





iO Series

Rate Compensation Heat Detectors


Series 302 heat detectors are designed for use in normal environments as well as environments
where the detectors are subject to weather, moisture (internal condensation), and explosive
Surface atmospheres. They are normally-open devices designed to close an electrical circuit upon
Mount activation. All models feature rate compensation and are available with either 135 °F (57.2 °C)
or 194 °F (90 °C) ratings. They are self restoring, hermetically sealed, shock and corrosion
resistant, and are tamperproof.
Initiating
Devices

Sensor’s Rated Minimum Ambient Maximum Ceiling


Temperature Air Temperature Temperature
135 °F (57.2 °C) -40 °F (-40 °C) 100 °F (38 °C)
194 °F (90 °C) -40 °F (-40 °C) 150 °F (66 °C)
Box
mount The sensor's aluminum tube acts as a heat collector when sources of heat radiate directly
on the tube. Install these sensors out of direct sunlight and away from radiating heat sources
including the direct flow from heaters and heat ducts.

302-AW-135 All-weather Heat Detector - Vertical Mounting FM & UL, 135 °F (57.2 °C) Data Sheet: 85001-0589
302-AW-194 All-weather Heat Detector - Vertical Mounting FM & UL, 194°F (90 °C) Data Sheet: 85001-0589
Notification
Appliances

302-ET-135 All-weather Heat Detector - Vertical, Box Mount (½" NPT), FM & UL, 135 °F (57.2 °C) Data Sheet: 85001-0589
302-ET-194 All-weather Heat Detector - Vertical, Box Mount (½" NPT), FM & UL, 194°F (90 °C) Data Sheet: 85001-0589
302-EPM-135 Heat Detector - Explosionproof Mounting UL (Not FM approved), 135 °F (57.2 °C) Data Sheet: 85001-0589
302-EPM-194 Heat Detector - Explosionproof Mounting UL (not FM approved), 194°F (90 °C) Data Sheet: 85001-0589
AP-P Adaptor plate for mounting 302 and 302-AW to any 3" box or 4" octagon outlet box Data Sheet: 85001-0589
STONCO27 3 ½" Weatherproof, round backbox and cover Data Sheet: 85001-0589
JALX11 Explosion proof outlet body with cover - Killark Data Sheet: 85001-0589
Hazardous Location

Explosionproof/weatherproof Manual Stations


Devices

MPSR Series explosionproof/weatherproof manual pull stations are noncoded fire alarm
stations solidly constructed of die-cast material. They are rated for Class I Group B (hy-
drogen) C & D, Class II Groups E. F, G, Class III environments, and are rated NEMA 4X for
outdoor use. Key and screw reset models feature terminal connections and come complete
with backbox.
Hex Screw Reset Cat 45 Key Reset Manual Stations Data Sheet: 85001-0588
  MPSR1-DHTWX-GE   MPSR1-D45WX-GE Explosionproof Single-action, SPST with backbox.
  MPSR1-SHTW-GE   MPSR1-S45W-GE Weatherproof Single-action, SPST with backbox.
  MPSR1-DHTW-GE   MPSR1-D45W-GE Weatherproof Single-action, DPDT with backbox.
  MPSR2-SHTW-GE   MPSR2-S45W-GE Weatherproof Double-action, SPST with backbox.
  MPSR2-DHTW-GE   MPSR2-D45W-GE Weatherproof Double-action, DPDT with backbox.
  MPSR2-SHTW-GE-NYW   MPSR2-S45W-GE-NYW Weatherproof Double-action, SPST with backbox, NYC white stripe.
For French markings add -F to the suffix of the model number. For bilinguial French/English markings add -B to the suffix of the model number.

MPSR-LP Double action cover for explosionproof manual stations


MPSRGR10 Replacement glass rods for MPSR stations (10 pack).
276-K1 Cat 45 Key (each)

36
iO Series Hazardous Location Devices

SUBMIT

 
Notification Appliances  


  

Hazardous Location Strobes


• Class I, II, or III locations
116DEGEX-FJ hazardous location strobes are life safety signaling appliances designed for installation in
hazardous environments. State-of-the-art technology provide for high visual output and low maintenance.
The 116DEGEX-FJ has negligible in-rush current. When pendant, wall or ceiling mounted, the 116DEGEX-
FJ meets or exceeds the requirements of UL 1971 Signaling Appliance for the Hearing Impaired.
116DEGEX-FJ Explosionproof Strobe, Diode Polarized Data Sheet 85001-0624
116EX-B Wall bracket mounting elbow Data Sheet 85001-0624
116EX-C Ceiling/wall mounting module Data Sheet 85001-0624
116EX-P Pendant mounting module - 3/4” (19 mm) NPT Data Sheet 85001-0624
116-GRD Lens Guard Data Sheet 85001-0624

Hazardous Location Bells


• Class I groups B, C and D locations • Class III hazardous locations, for Divisions 1 and 2
• Class II groups E, F and G locations
430D series of hazardous location bells are diode-polarized, heavy duty fire bells for use in life safety applications
where a diode supervised signal is required. They can be mounted to any solid surface using two 3/8 inch (10 mm)
bolts and the supplied mounting brackets or to a rigid conduit. The integral explosion-proof housing is mechanically
terminated to accept a standard 3/4 inch -14 National Pipe Taper (NPT) nipple.
  439DEX-6AW (6”)   439DEX-8AW (8”)   439DEX-10AW (10”) Bell – 24 Vdc Data Sheet 85001-0399
  438DEX-6N5 (6")   438DEX-8N5 (8")   438DEX-10N5 (10") Bell – 120 Vac Data Sheet 85001-0399

Hazardous Location
Hazardous Location Horns
• Class I groups B, C and D locations • Class III hazardous locations, for Divisions 1 and 2

Devices
• Class II groups E, F and G locations
888D and 889D hazardous location horns are diode-polarized, heavy duty, high decibel vibrating horns intended for
use in life safety systems in hazardous (classified) locations. These horns may be mounted to any solid surface using
two bolts. Each unit is supplied with a sealing fitting for a 3/4 inch -14 National Pipe Taper (NPT) nipple, and wire leads
for the electrical connection to the life safety system notification appliance circuit.
  888D-N5 (120 Vac)   889D-AW (24 Vdc) Horn – 120 Vac Data Sheet 85001-0397
Door Holders
& Relays

37
iO Series
SUBMIT
Door Holders & Relays

 
Intelligent Control




  
iO Series

Door Holders
  Electromagnetic Door Holders
Edwards electromagnetic door holders keep doors open until signaled by the
fire alarm system, a heat detector, a smoke detector, or an electrical switch.
Door holders should be installed wherever doors may be effectively used to
confine smoke and fire, or where the release of a self-closing door from a
remote location is required. Fail-safe operation is an inherent feature of these
door holders. If power fails, doors are released automatically, but may be
24 Vac 60 Hz opened or closed manually at any time. All units are free of moving parts, are
Initiating
Devices

24 Vdc self-contained, and require no maintenance. Door holders have a holding force
120 Vac 60 Hz of approximately 15-25 Lbf (66-111N).
 1501-AQN5 (Single Door)  1502-AQN5 (Double Door) Floor Mounted Data Sheet 85001-0421
 1504-AQN5 (Long Catch Plate)  1505-AQN5 (Short Catch Plate) Flush Wall Mounted Data Sheet 85001-0421
 1508-AQN5 (Surface)  1505-AQN9 (Completely flush) Wall Mounted Data Sheet 85001-0421
 1500-1 (1.5” Extension)  1500-2 (2.5” Extension) Catch Plate Data Sheet 85001-0421
 1500-7 (5.25 to 7.5” Extension)  1500-12 (7.5 to 12” Extension) Catch Plate Data Sheet 85001-0421
 CS2595-5 (short)  CS2598-5 (long) Replacement Armature Data Sheet 85001-0421
Notification
Appliances

Relays
Four-Voltage SPDT/DPDT Control Relays
MR Series multi-voltage control relays are ideal for applications where local contacts are
required for system status, remote contacts, or for control of electrical loads and general pur-
pose switching. They are suitable for use with HVAC temperature control, fire alarm, security,
energy management, and lighting control systems. Relays provide 10-Amp contacts, which
Hazardous Location

may be operated by one of four input control voltages. Each relay position contains a red
LED that indicates the relay coil is energized. Relays may be snapped apart from a standard
four-module assembly and used independently.
Devices

 MR-101/T (with mounting hardware)  MR-101/C (in metal enclosure) Single SPDT relay Data Sheet 270062
 MR-104/T (with mounting hardware)  MR-104/C (in metal enclosure) 4-position SPDT relay Data Sheet 270062
 MR-201/T (with mounting hardware)  MR-201/C (in metal enclosure) Single DPDT relay Data Sheet 270062
 MR-204/T (with mounting hardware)  MR-204/C (in metal enclosure) 4-position DPDT relay Data Sheet 270062

Heavy Duty DPDT Power Relays


MR-199 heavy duty power relays are designed for control applications where 30-Amp DPDT
contacts are required. Two models are available: a 115Vac coil and a 24Vdc coil, each of
Door Holders

which may be mounted in a rugged steel enclosure.


& Relays

 MR-199X-13 (relay only)  MR-199X-13/C (in metal enclosure) Power Relay — 24 VDC Data Sheet 270065
 MR-199AX-14 (relay only)  MR-199AX-14/C (in metal enclosure) Power Relay — 120 VDC Data Sheet 270065

38
iO Series Door Holders & Relays

SUBMIT

 



  
SPDT Relays
Single-pull/double-throw relays are ideal for applications where local or remote con-
tacts are required for control of electrical loads. They are suitable for use with HVAC,
temperature control, fire alarm, security, energy management, and lighting control
systems. Each relay position contains a high-intensity LED which, when illuminated,
indicates the relay coil is energized. Individual relay circuits may be snapped apart
from standard four- or eight-position modules, and are also available in a single-circuit
configuration. The common power to each relay position is bussed on the printed
wiring board, which permits power to be connected only once per multi-position
module.

Single-Voltage Manual Override Relays


MR-600 series relays provide SPDT, 10-Amp contacts with manual override capability by means of an ON-AUTO-OFF
switch. The relay requires a 24Vac or 24Vdc power source supplied by the controlling system. With the switch in the ON
position the power relay is energized. With the switch in the AUTO position the relay is allowed to operate as signaled
by the controlling system. With the switch in the OFF position the relay cannot be energized.
 MR-601/T (with mounting track)  MR-601/S (with mounting spacers)  Single SPDT relay Data Sheet 270061
 MR-604/T (with mounting track)  MR-604/S (with mounting spacers)  4-position SPDT relay Data Sheet 270061
 MR-608/T (with mounting track)  MR-608/S (with mounting spacers)  8-position SPDT relay Data Sheet 270061

Three-Voltage Control Relays


MR-800 Series relays provide SPDT 10-Amp contacts that may be operated by one of three input control voltages:
24Vdc, 24Vac or 115Vac.
 MR-801/T (with mounting track)  MR-801/S (with mounting spacers)  Single SPDT relay Data Sheet 270063
 MR-804/T (with mounting track)  MR-804/S (with mounting spacers)  4-position SPDT relay Data Sheet 270063
 MR-808/T (with mounting track)  MR-808/S (with mounting spacers)  8-position SPDT relay Data Sheet 270063

Four-Voltage Control Relays


MR-700 Series relays provide SPDT 10-Amp contacts that may be operated by one of four input control voltages:
12Vdc, 12Vac, 24Vdc, or 24Vac.
 MR-701/T (with mounting track)  MR-701/S (with mounting spacers)  Single SPDT relay Data Sheet 270064
 MR-704/T (with mounting track)  MR-704/S (with mounting spacers)  4-position SPDT relay Data Sheet 270064
 MR-708/T (with mounting track)  MR-708/S (with mounting spacers)  8-position SPDT relay Data Sheet 270064
Door Holders

Three-Voltage Encapsulated Control Relays


& Relays

PAM-1 relays provide 10-Amp Form C contacts. The relay may be energized by one of three
input voltages: 24Vac, 24Vdc, or 115Vac. The PAM-1 may be mounted with double-sided
adhesive tape, a self-tapping screw, or loosely placed in a backbox.

PAM-1 Encapsulated SPDT relay Data Sheet 270066

39
Proven leadership. In 1872 when Robert Edwards Now we have access to the

Proud heritage. installed an electrically-operated combined resources, talent, and

gas lamp igniter in a New York experience that is already setting


Shared vision.
City church, he began a tradition a coordinated plan for excellence

of innovation that would chart into action. The result is a unique


the course of building safety and synergy sustained by a strong

security for the next 140 years. organization with a well-defined


Today the company that bears his vision of the future.

name draws on this rich legacy of That vision of excellence

inventiveness, and benefits from is why, with more than a century


fresh new alliances established of solid growth behind us, you can

with one underlying goal: put your trust in Edwards.

uncompromised excellence.

Our EST brand under Our respected brand


represented exclusively
the Edwards banner meets by EST Strategic Partners:

this goal with quality products

and an exceptional sensitivity

to the needs of our customers.

40
Innovation, leadership,
and a rich tradition of excellence
Whether EST life safety systems are protecting the lives and livelihoods of the
people who make businesses run, or the lives entrusted to the care of public
institutions; whether they’re charged with protecting the guests of the world’s
finest hotels, or preserving irreplaceable artifacts that bring history to life; EST
stands alone as the brand closely associated with some of the most important
and far-reaching developments in the life safety industry today.

Our strength is in our Strategic Partners — the people and organizations


we entrust with the technology that has charted the course of life safety protec-
tion for decades. Strategic Partners are not middlemen or go-betweens. They
are independent contractors that form an integral part of the Edwards marketing
and support organization. As insiders, they enjoy exclusive access to products,
custom design innovations, specialized training, and factory direct pricing. Yet
as successful independent contractors, they are adept at ensuring that each
submittal is strong and competitive, and that each bid is locally relevant to your
installation. As local businesses they not only have to earn your trust — they
have to keep it.

Together these strengths set EST installations apart, and have earned this
brand a special place among life safety and security solutions available today.
Perhaps that’s why EST products and systems have become the choice of
building owners, architects and engineers around the globe. And why many of
the world’s most cherished landmarks are protected by Edwards products that
bear the EST mark. From the Bibliotheca Alexandrina Museum in Egypt, to the
modern-day sphinx at the Luxor Hotel in Las Vegas, professionals who design,
own and occupy the world’s most impressive structures have come to know
that the safest and most survivable solution today is an EST solution.

Contact us...
Email: edwards.fire@fs.utc.com
Web: www.est-fire.com See what’s possible now.
EST is an EDWARDS brand. Contact your EST Strategic
1016 Corporate Park Drive
Mebane, NC 27302
Partner today.
In Canada, contact Chubb Edwards...
Email: inquiries@chubbedwards.com
Web: www.chubbedwards.com

© 2014 United Technologies


Corporation, Inc. All rights reserved.
Specifications subject to change
without notice. EDWARDS is part of
UTC Building & Industrial Systems.
11-04-14

85005-0132 Issue 3