Intelligent Control
iO Series
Submittal Guide
iO Series
Initiating
Devices
Intelligent fire alarm solutions for small buildings
Notification
Appliances
Hazardous Location
Devices
Door Holders
& Relays
An EDWARDS brand.
Se
w.
S
e e w
e no
h a ha t’s possible
w
..
t
's w.
no
possible
Intelligent Control
iO Series
Project: ___________________________
Contact: ___________________________
Date: ___________________________
Initiating
Devices
Thank you for giving us the opportunity to provide this submittal for an iO
Series Life Safety System. iO Series combines analog addressable detection
with technologically advanced sensor diagnostic capabilities. Together these
innovations offer unsurpassed stability, reliability, and flexibility.
Notification
Appliances
comprehensive presentation of related system components and devices.
Products we are submitting for your consideration are indicated by a
checkmark in the margins of the pages that follow.
Hazardous Location
useful product information, are available electronically on our LifeLines
CD-ROM. This exhaustive collection of life safety related literature is fully
Devices
searchable.
Thank you for giving us the opportunity to provide this submittal. Please do
not hesitate to contact us should you require further information.
Door Holders
& Relays
_____________________________
iO Series Initiating Notification Hazardous Location Door Holders
Intelligent Control Devices Appliances Devices & Relays
iii
Intelligent fire alarm solutions for small buildings
iO Series
Submittal Guide
iO Series Submittal Guide
Intelligent fire alarm solutions for small buildings
© 2014 United Technologies Corporation
All rights reserved. Specifications subject to change without notice.
EDWARDS is part of UTC Building & Industrial Systems.
1016 Corporate Park Drive, Mebane, NC 27302
85005-0132, Issue 3
Wiring diagrams provided herein are for information and reference only and are not to be used for installation pur-
poses. Consult the appropriate installation documents for wiring and configuration details.
This guidebook is for information only and is not intended as a substitute for verbatim legislated requirements. For
authoritative specifications regarding the application of life safety, security, and access control systems, consult
current editions of applicable codes and standards. For authoritative interpretation of those codes and standards,
consult your local authority having jurisdiction.
While every effort has been made to ensure the accuracy and completeness of this guidebook, the authors and
publishers assume no responsibility for errors, inaccuracies, omissions, or any inconsistencies herein.
EST, Genesis Series, and Signature Series are trademarks of United Technologies Corporation.
iO Series Life Safety Systems
Intelligent Control
iO Series
Cohesive, iO Series Analog
System Specifications....................................................... 2
1
Initiating
buildings.
Devices
Intelligent Analog Initiating Devices 11
Combination CO/Fire Detectors....................................... 12
With control panels, devices, and accessories all Fire Detectors.................................................................. 13
Duct Smoke Detectors.................................................... 13
engineered to work in unison, iO Series systems Detector Bases............................................................... 14
provide reliable performance and the advanced Detector Accessories...................................................... 15
Input/Output Modules..................................................... 16
features you need for successful installation and
Pull Stations.................................................................... 22
worry-free operation. Best of all, iO Series leaves
Notification
Appliances
you in control – not hemmed in by a limited product Notification Appliances 23
line. EST’s extensive range of fire alarm products Wall Strobes, Horns & Chimes......................................... 25
Wall Speakers and Speaker-strobes................................ 26
gives you the freedom to tailor each system to the
LED Strobes, Horn-Strobes............................................. 26
particular needs of the building – and the budget Ceiling Speakers, Horns, and Strobes............................. 27
of the building owner – while a robust feature set Low Frequency Horns and Strobes................................. 27
Outdoor Speakers and Speaker-Strobes......................... 28
leaves plenty of room for upgrades, expansions,
Hazardous Location
Outdoor Horns and Horn-Strobes................................... 29
and retrofits long into the future. Harsh Environment Signals.............................................. 30
Genesis Signal Master..................................................... 31
But innovative features tell only part of the
Devices
Audible Signals................................................................ 31
story: when you specify iO Series you’re getting Audio Notification System................................................ 32
Accessories..................................................................... 33
more than outstanding value in a fire alarm panel;
you’re benefitting from a whole family of control,
Hazardous Location Devices 35
detection, and notification appliances finely tuned Initiating Devices............................................................. 36
to work together – engineered and tested to func- Notification Appliances.................................................... 37
Door Holders................................................................... 38
ing the needs of the future, iO Series is the chang- Relays............................................................................. 39
ing face of small building fire detection today. SPDT Relays................................................................... 39
v
See what’s
possible now.
D e t e c t i o n & A l a r m S i n c e 1 8 7 2 .
Mass Notification • Smoke Detection • Graphical Monitoring and Control • Instant Messaging • Aspirating Smoke Detectors • Industrial
Signaling • Voice Evacuation • Smoke Control • Fire Suppression • Intercom • Timekeeping • CO Detection • Heat Detection •
Audible & Visible Signaling • Voicemail Messaging • Duct Smoke Detection • Giant Voice • Electronic Signage • Area of Rescue
iO Series Intelligent Control
Specifications p. 2
Control Panels p. 3
Intelligent Control
Option Cards p. 4
iO Series
Power Supplies p. 6
Remote annunciation p. 8
Accessories p. 10
Initiating
Devices
iO Series life safety systems are a powerful intelligent solu- Signals with a difference
tion for small to mid-sized buildings. Advanced analog tech- iO Series NACs are configurable to fully support the ad-
nology delivers the benefits of flexible system installation, vanced signaling technology of Edwards Genesis and En-
while a clean and easy-to-operatate user interface makes hanced Integrity notification appliances. These devices offer
panel operation and system maintenance quick and intuitive. precision synchronization of strobes to UL 1971 standards.
For Genesis devices, enabling this feature allows connected
The smart choice horns to be silenced while strobes on the same two-wire
Notification
Signature Series electronic addressing eliminates the tedium circuit continue to flash until the panel is reset.
Appliances
of setting dipswitches, and automatic device mapping en-
sures that each device resides on the system at its correct Clear-cut remote annunciation
location. Meanwhile, innovative programming features allow Remote annunciation is a strong suit of iO Series. Up to
the system designer to customize powerful built-in features eight annunciators can be installed on a single system.
to precisely suit the needs of Compatible annunciators include
the building owner. a range of LED and LCD models
that provide zone or point an-
Flexibility built right in nunciation, as well as common
Two fully-programmable front control capabilities.
Hazardous Location
panel switch/LED combi-
iO Series also supports graphic
nations provide an added
annunciation with optional RA
measure of flexibility. Their
Devices
Graphic Annunicator interface
slide-in labels take the mystery
modules. Each interface provides
out of custom applications,
common control, indicators, and
and present a clean finished
32 LEDS.
appearance.
A complete line of accessories
Perfect for retrofits iO Series life safety systems are
iO Series is particularly well- supported by a complete line of
suited to retrofit applications. intelligent detectors, modules and
All connections are made over related equipment, each of which
standard wiring – no shielded
Door Holders
1
Intelligent Control
Specifications
iO Series
iO500: one loop that supports up to 250 intelligent devices. Optional second loop (iO500)
Can be expanded to two loops. Each loop supports up to 125
detectors and up to 125 modules.
2
iO Series Intelligent Control
SUBMIT
Intelligent Control
Control Panels
iO Series
Standard Features Dimensions
All iO Series life safety systems feature an attractive design that Surface mounting holes
D2 D3
fits with any decor. Its distinctive doorfront offers a contemporary
look that’s available with red or silver finishes. All LED indicators
and its large backlit display remain easy to see at all times.
Initiating
• Optional Ethernet port for diagnostics, programming and a variety
Devices
of reports
• Two programmable switches with LEDs and custom labeling
Surface mounting holes
• Supports Genesis horn silence over two
wires and UL 1971-compliant strobe
synchronization D6
• Supports up to eight serial annunciators, D5
(LCD, LED-only, and graphic interface).
Panel dimensions, in (cm)
• Can use existing wiring for most retrofit Model D1* D2 D3 D4 D5* D6
applications 28.0 3.85 9.0 22.0 15.75 10.25
iO500
• Upload/download remotely or locally (71.1) (9.8) (22.8) (55.8) (40.0) (26.0)
Notification
21.50 3.85 7.5 15.5 14.25 10.25
Appliances
• Two-level maintenance alert reporting iO64
(54.6) (9.8) (19.0) (39.4) (36.2) (26.0)
• Pre-alarm and alarm verification by point * Add 1-1/2 in. (3.81 cm) to D1 and D5 dimensions for trim kit.
Hazardous Location
iO500R 1 Loop System, 500 analog point capacity, 4 NACs, red Door, surface enclosure, 115VAC, English.
iO500R-2 1 Loop System, 500 analog point capacity, 4 NACs, red door, surface enclosure, 230VAC, English
Devices
iO500RD 1 Loop System, 500 analog point capacity, two-line dialer, 4 NACs, Red Door, surface enclosure, 115VAC, English.
D16L-iO-2 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to right of display.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM2 Flush mount trim, black
iO64G-2 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 230VAC, English.
& Relays
iO64R-2 1 Loop System, 64 point capacity, 2 Class B NACs, Red door, surface enclosure, 230VAC, English.
iO64GL 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, English, Canadian.
iO64GL-F 1 Loop System, 64 point capacity, 2 Class B NACs, Gray door, surface enclosure, 115VAC, French, Canadian.
D16L-iO-1 LED Annunciator Module, 16 groups, 2 LEDs per group. Mounts in cabinet on iO500 systems. Mounts to left of display.
SA-TRIM1 Flush mount trim, black
3
iO Series
SUBMIT
Intelligent Control
Option Cards
Intelligent Control
iO Series
SA-232 RS-232
interface
SA-CLA Class A
Module
iO-Series panels are supported by a complete line of modules and related equipment that
enhance performance and extend system capabilities. Option cards are easy to install and set
up. They simply plug directly into the control panel main circuit board or are connected to it
with a ribbon cable. After installation, terminals remain easily accessible for quick connection of
field wiring. The cabinet provides ample room for wire routing, keeping wiring neat and easy to
service at all times.
SA-CLA wiring
TB2 on main NAC1
+ + SA-CLA Class A Module
circuit board NAC1+
NAC2
+ + The SA-CLA card provides Class A capability for NAC and annuncia-
NAC2+ tor wiring. Its terminal block provides the wiring connection for NAC
return wiring. The card is required for annunciator Class A wiring even
+ though this wiring does not return to the SA-CLA card. The SA-CLA
is compatible with iO64 control panels only. iO500 panels are Class
+ A ready. The SA-CLA is installed directly to the control panel circuit
Class A card installed
board using its plastic standoffs and plug connection.
on main circuit board
SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board.
SA-ETH wiring
To network
connection
Network cable
SA-ETH Ethernet Interface Card
The SA-ETH card provides a standard 10/100 Base T Ethernet network connection
for connecting to an intranet, a local network, or the Internet. The card can be used
to upload and download panel configuration, history, and current status from the
iO-CU to the panel over the network.
The Ethernet card is installed on the plastic assembly and connects to the main
circuit board via a ribbon cable.
Ethernet card
SA-ETH Ethernet Port, Slave, for Ethernet connection to local area networks. Mounts in cabinet on base plate.
SA-232 wiring
GND (black wire)
TXD (white wire)
SA-232 RS-232 interface
RXD (red wire)
The SA-232 card provides an RS-232 interface with iO-Series panels. It can be used for
connecting a printer to the control panel to print system events. The card also can be used
for connecting a computer to download a configuration program from the iO-CU to the
control panel.
The RS-232 card is installed on the plastic assembly and connects to the main circuit board
via a ribbon cable.
SA-232 Serial Port (RS-232), for connection to printers & computers, mounts in cabinet to base plate
4
iO Series Intelligent Control
SUBMIT
Intelligent Control
iO Series
SA-DACT Phone line 1
wiring
To wall
Phone line 2 phone jack
Phone cables
RJ31 jacks
(supplied)
SA-DACT Dialer
The SA-DACT provides communications between the control panel and the central
station over a telephone line system. It transmits system status changes (events)
to a compatible digital alarm communicator receiver over the public switched tele-
phone network. The dialer is capable of single, dual, or split reporting of events to
Initiating
Devices
two different account and telephone numbers. The modem feature of the SA-DACT
can also be used for uploading and downloading panel configuration, history, and
current status to a PC running the iO-CU.
The dialer phone lines connect to connectors on the dialer’s main circuit board.
Phone line 1 connects to connector J4 and phone line 2 connects to connector J1.
SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate
Notification
Appliances
The SMK Smoke Power Converter Module provides a backup power source for
two-wire smoke circuits connected to a Signature data circuit. The SMK monitors 24 VDC
the operating power from the power supply. When power begins to degrade, the auxilliary +
24 VDC
power _
SMK provides the necessary operating voltage to the two-wire smoke detection (notauxilliary
resettable) +
power _
circuits. (not resettable)
Hazardous Location
+ +
- + + 4 3 2 1
Loop 1 PRI
+ - -
Loop Loop Two-wire smoke
detectors
Devices
device device
Loop card Two-wire smoke
detectors
XAL250 Loop Expander Card (iO500 Systems only) 16 15 14 13 3 2 1 12 11 10 9
Class B wiring Class A wiring +
JP1
16 15 14 13 3 2 1 12 11 10 9
Class B Wiring Class A Wiring
+
JP1
- - 8 7 6 5 4 3 2 1
Loop 1 SEC Loop 1 SEC
Data Line
+ +
8 7 6 5 4 3 2 1
- + +- + + Data in +
Loop 1 PRI Loop 1 PRI
+ - -+ - -
Data in
+
Loop Loop Loop Loop Two-wire smoke
device Loopdevice
card device device detectors
Loop card Data Line Two-wire smoke
detectors
The
Class AXAL250
wiring Loop Expander Card provides an additional Signature 16 15 14 13 3 2 1 12 11 10 9
Door Holders
+
Series device loop on the control panel. The card expands the control 16 15 14 13 JP1
3 2 1 12 11 10 9 Terminate
& Relays
+ or to next
panel’s device - capacity to 500 total device addresses, 250 per loop. JP1 UM
Terminate
or to next
Loop 1 SEC 8 7 6 5 4 3 2 1
The card is+compatible with Class B or Class A wiring. It is compatible UM
Loop card Data Line
XAL250 Signature Loop Expansion Module. Adds second loop to iO500 systems, 250 point capacity.
5
iO Series
SUBMIT
Intelligent Control
Power Supplies
Intelligent Control
iO Series
Booster
mainthatpanel’s notification appliance circuit. This allows seamless expansion of existing NACs.
can be connected
together is limited by wire
Power Supply run length and available current
For comprehensive configuration and wiring details, refer to the BPS Application Guide,
85001-0582.
Parallel Connection
The number of boosters
that can be connected
together is limited by wire
run length and available current
6
iO Series Intelligent Control
SUBMIT
Intelligent Control
iO Series
Auxiliary Power Supply (APS)
TB1
Notification
The Auxiliary Power Supply (APS) is a self-
+
NAC1 appliance contained 24 Vdc power supply designed
circuit (NAC)
to augment fire alarm audible and visual
+
NAC2
Notification
power requirements as well as provide
+
NAC3 appliance
circuit (NAC) auxiliary power for life safety and security
+
NAC4
200 mA AUX
applications. The APS contains all of the
TB5
IN
Sense 1 COM
+
batteries, control and supervise four Class
Initiating
-
B or two Class A NAC circuits and moni-
Devices
OUT To next signaling device, NAC
IN
+
Notification
Appliances
Batteries and Battery Cabinets
12 Volt Batteries 12V4A (4.5 Ah) 12V6A5 (7.2 Ah) 12V10A (11 Ah) Data Sheet 85005-0127
12V1A2 (1.2 Ah) 12V24A (26 Ah) 12V17A (18 Ah) Data Sheet 85005-0127
6 Volt Batteries 6V8A (8 Ah) 6V10A (12 Ah) Data Sheet 85005-0127
Data Sheet 85005-0127
Hazardous Location
Battery Cabinet BC-1 (holds up to two 40 Ah batteries)
Devices
Door Holders
& Relays
7
iO Series
SUBMIT
Intelligent Control
Remote annunciation
Intelligent Control
iO Series
Reset
Signal Silence
Lamp Test
RLCD
Reset
Signal Silence
Reset
Lamp Test
RLCD-C RLED-C Two models have an LCD text display, and one has 16 pairs of
LEDs for zone annunciation. LCD models feature a large back-lit,
FACP Annunciator Annunciator
RS-485 CH1 (+) IN CH1 (+) IN
Power
Fire Alarm
Supervisory
four by twenty
CH1 +character per line, super-twist
CH1 (–) IN liquid crystal
CH1 (display.
–) IN
Ground Fault
Trouble CH1 – CH1 (+) OUT CH1 (+) OUT
ables or disables common controls. The graphic annunicator interface cards supports 32 LEDs and 16 switches on
Power
Fire Alarm 24V (–) OUT 24V (–) OUT
Supervisory
Ground Fault
Trouble
Signal Silence
Lamp Test
GROUND GROUND
GROUND GROUND
RLCD
FACP
LCD text Annunciator
annunciator without common controls. English.
Annunciator
Data Sheet 85005-0128
Annunciator First Expander Second Expander
RLCD-R
RS-485
LCD text annunciator without common controls. English. Red.OUT
CH1 (+) IN
CH1 (+) IN
IN Data Sheet 85005-0128
OUT IN OUT
CH1 + CH1 (–) IN CH1 (–) IN
V (–) V (–) V (–) V (–) V (–)
RLCDF
CH1 – LCD text CH1
annunciator
(+) OUT without common controls. French.
CH1 (+) OUT
V (+) V (+) Data Sheet 85005-0128
V (+) V (+) V (+)
CH1 (–) OUT CH1 (–) OUT
F F F F F
RLCD-C LCD text CH2
annunciator
(+) IN with common
CH2controls.
(+) IN English. E E Data
E Sheet 85005-0128
E E
CH2 (–) IN CH2 (–) IN
D D D D D
RLCD-CR
LISTED 24 VDC LCD text CH2
annunciator
(+) OUT with common
CH2controls.
(+) OUT English. Red. C C Data
C Sheet 85005-0128
C C
SUPPLY CH2 (–) OUT CH2 (–) OUT
RLCD-CF LCD text 24V
annunciator with common
24Vcontrols. French. Data Sheet 85005-0128
B B B B B
24 VDC + (+) IN (+) IN
A A A A A
24 VDC – 24V (–) IN 24V (–) IN
RLED-C 16-pair LED
24V (+)zone
OUT annunciator with24Vcommon
(+) OUT controls. English. Data Sheet 85005-0128
24V (–) OUT 24V (–) OUT
RLED-CR 16-pair LED zone annunciator with common controls. English. Red. Data Sheet 85005-0128
GROUND GROUND
RLED-CF 16-pair LED zone annunciator with common controls. French. Data Sheet 85005-0128
RLED24 24-pair LED zone expander with expander cable and zone card insert. Data Sheet 85005-0128
RLED24R Annunciator24-pair LEDFirst
zone expander withSecond
Expander
expander
Expander
cable and zone card insert. Red. Data Sheet 85005-0128
OUT IN OUT IN OUT
SUBMIT
Intelligent Control
iO Series
Annunciator Enclosures
The RA Remote Annunciator Enclosures provide secure, surface mounted protec-
tion for annunciators and extenders. Each consists of a back plate, hinged cover,
and key lock. The enclosures are 16-gauge welded steel with a white, painted
finish. Each enclosure includes a security lock and two keys. The two- and three-
RA-ENC1
position enclosures have wiring channels for correct routing of interconnections.
The enclosures attach to a standard electrical box, and provide a mounting lip
that takes the place of the integral mounting ring supplied with the annunciators
and expanders.
Initiating
Devices
RA-ENC3
RA-ENC2
Notification
Appliances
Graphic Annunication
The GCI series of graphic annunicator drivers allow iO control panels to
display events on an LED-based graphic annunciator. The GCI annun-
ciator card supports 32 LEDs on the graphic panel display. It includes
status LEDs and an internal buzzer. The graphic card is supplied with
snap track mounting. It is attached to a plastic mounting rail that requires
two EIA panels.
The annunciator communicates with the control panel on the RS 485
Hazardous Location
data riser, which can be configured for Class A or Class B communica-
tion. The annunciator does not provide ground fault isolation. The driver
card communicates with and is powered by the control panel or by an 24VDC FROM 3-PPS/M 24VDC TO NEXT
Devices
OR 3-BPS/M POWER RISER POWER MODULE
approved power supply. Always ensure that National and Local approv- RS-485 NETWORK DATA RS-485 NETWORK DATA
als and requirements are met when selecting a graphic panel supplier. FROM PREVIOUS PANEL TO NEXT PANEL
Door Holders
& Relays
9
iO Series
SUBMIT
Intelligent Control
Accessories
Intelligent Control
iO Series
Riser in
Master Box
The City Tie Module provides a simple way of connecting iO
from
Panel CC1 CTM
/MCC1
Series to a local energy fire alarm box or City Master Box. One Data in
are required.
CTM City Tie Module Data Sheet 85005-0097
10
iO Series Intelligent Initiating Devices
Fire Detectors p. 13
Detector Bases p. 14
Detector Accessories p. 15
Signature Series
Intelligent Analog
Input/Output Modules p. 16
Pull Stations p. 22
Initiating Devices
Initiating
Devices
iO Series Signature Series intelligent analog- Automatic Device Mapping – The Signature Loop Con-
addressable system is an entire family of life safety detectors troller learns where each device’s serial number address is
as well as mounting bases, multiple-function input and output installed relative to other devices on the circuit. This map-
modules, and user-friendly maintenance ping function is invaluable for tracking down unexpected
and service tools. or missing device addresses, or finding changes to wiring.
The System Definition Utility program also uses this map-
Making the best of true multisensor capa-
ping feature to produce system layout or As-Built drawings
bility, Signature Series detectors continu-
showing such details as banch wiring (T-taps), device types
ally monitor the protected space with their
and their addresses.
on-board sensors, each of which is finely
tuned to detect a different characteristic Fast Stable Communication – Built-in intelligence means
of combustion. All this information is
Notification
less information needs to be sent between the device and
Appliances
gathered and run through a sophisticated the Signature Loop Controller, making the circuit less sensi-
algorithm that compares the sensor read- tive to noise and wire characteristics. This renders shielded
ings over time to known signatures of fires. wiring unnecessary. In fact, existing wiring can be used by
Only when a match is found will an alarm Signature Series devices in most retrofit situations.
condition occur. This means that a single
multisensor detector can distinguish be- Testing & Maintenance – Each detector automatically iden-
tween a harmless puff of dust and a wisp tifies when it is dirty or defective and causes a “dirty detector”
of smoke; between hot, humid weather message. The detector’s sensitivity measurement can also
and a serious life safety condition. be transmitted to the loop controller. A sensitivity report may
be printed to satisfy NFPA sensitivity measurements. The
Hazardous Location
Self-diagnostics and History Log – Sig- user-friendly maintenance program shows the current state
nature Series devices constantly run self-checks to provide of each detector and other pertinent messages. When the
important maintenance information. The results of these CO sensor’s electrochemical cell reaches its end of life, the
detector signals a trouble condition to the control panel. The
Devices
checks are automatically updated and permanently stored
in the device’s non-volatile memory. sensor/daughterboard module is field-replaceable.
Class B wiring
Class B Class A
- -
Loop 1 SEC Loop 1 SEC
Data Line
+ +
Typical Wiring
- + +- + +
Loop 1 PRI Loop 1 PRI
+ - -+ - -
Loop Loop Loop Loop
device Loopdevice
card device device
Loop card Data Line
Class A wiring
-
11
Loop 1 SEC
+
iO Series
SUBMIT
Intelligent Initiating Devices
Intelligent Control
iO Series
devices include electrochemical carbon dioxide sensors. CO detection has rapidly become
a standard part of life safety strategies everywhere. Monitored CO detection is becoming
mandated with increasing frequency in all types of commercial applications, but particularly
in occupancies such as hotels, rooming houses, dormitories, day care facilities, schools,
hospitals, assisted living facilities, and nursing homes. In fact, more than half of the U.S.
population already lives in states requiring the installation of CO detectors in some com-
mercial occupancies. This is because carbon monoxide is the leading cause of accidental
poisoning deaths in America. Known as the “Silent Killer,” CO is odorless, tasteless, and
colorless. It claims nearly 500 lives, and results in more than 15,000 hospital visits annually.
12
iO Series Intelligent Initiating Devices
SUBMIT
Fire Detectors
Intelligent Multisensor Photoelectric/Heat Detector
Contains a fixed-temperature heat sensor to detect heat from fire and a photoelectric smoke sensor to detect smoke.
Unlike simple multi-criteria detectors, the SIGA2-PHS can report the heat and photo elements as separate event types
— or together. This permits the photo element of the detector to report, for example, a supervisory event during the
day, and an alarm event at night – while the heat element always reports an alarm.
SIGA2-PHS Intelligent Multisensor Photoelectric/Heat Detector Data Sheet: 85001-0621
SIGA-PHS Intelligent 3D Multisensor Detector, White Data Sheet 85001-0247
Initiating
Devices
Intelligent Photoelectric Detector
The workhorse of modern fire alarm systems, this devices includes a photoelectric smoke sensor to detect smoke.
SIGA2-PS Intelligent Photoelectric Detector Data Sheet: 85001-0619
SIGA-PS Intelligent Photoelectric Detector, legacy housing Data Sheet: 85001-0269
Notification
Appliances
Intelligent Fixed Temperature Heat Detector
Includes a fixed-temperature sensor to detect heat from fire.
SIGA2-HFS Intelligent Fixed Temperature Heat Detector Data Sheet: 85001-0620
SIGA-HFS Intelligent Fixed Temperature Heat Detector, legacy housing Data Sheet 85001-0243
Hazardous Location
SuperDuct Detectors
Devices
Less than two inches deep, SuperDuct intelligent smoke detectors are ideal
Alarm relay output Remote
test station
for installation in ductwork, where space is always at a premium. Offering
the most advanced and most reliable performance in its class, SuperDuct
Duct smoke Return represents the perfect balance of practical design and advanced technology.
detector air
HVAC
unit SuperDuct detectors feature a unique design that speeds installation and
Duct smoke Supply simplifies maintenance. Removable dust filters, conformally coated circuit
detector air
boards, and optional water-resistant gaskets keep contaminants away
Alarm relay output
from components, ensuring years of trouble-free service. When cleaning
Remote
test station is required, the assemblies come apart easily and snap back together in
FACP
seconds.
Door Holders
& Relays
13
iO Series
SUBMIT
Intelligent Initiating Devices
Intelligent Control
Detector Bases AB4GT AB4GT
iO Series
Listed 24
V EOL
3
AUX_RISER + Supervising
AUX_RISER -
Equipment
Temporal Pattern Generator, is compatible with any Signature Series detector, and is field-configurable
for: CO or non-CO detectors; output tone (steady or temporal); and, for output volume (low or high dBA).
The SIGA-AB4G is compatible with the SIGA-PS detectors only.
Initiating
Devices
SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors Data Sheet: 85001-0623
SIGA-TCDR Temporal Pattern Generator for SIGA-AB4GT Data Sheet: 85001-0623
SIGA-AB4G Audible (Sounder) Base for SIGA-PS Detectors Only Data Sheet: 85001-0581
AB4G-SB Surface Box for Audible Bases Data Sheet: 85001-0623
SIGA-SB SIGA-SB4 (with trim skirt) Standard Detector Base Data Sheet: 85001-0245
SIGA-IB SIGA-IB4 (with trim skirt) Isolator Detector Base Data Sheet: 85001-0245
SIGA-RB SIGA-RB4 (with trim skirt) Relay Detector Base Data Sheet: 85001-0245
14
iO Series Intelligent Initiating Devices
SUBMIT
Detector Accessories AUX_RISER_IN +
1
AUX_RISER_OUT +
A
2
SLC_IN + SLC_OUT +
Initiating
Devices
SIGA-TCDR Temporal Pattern Generator for AB4GT Sounder Base Data Sheet: 85001-0623
Notification
Appliances
Remote LED
The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base. It features a North
American size one-gang plastic faceplate with a white finish and red alarm LED.
Hazardous Location
Trim Skirt
Use the SIGA-TS Trim Skirt to give Signature detectors a finished look and hide surface
Devices
imperfections around the detector’s base. Supplied with all four-inch detector bases, the
SIGA-TS4 can also be ordered separately. Use the black model with SIGA-IPHSB.
Detector Guard
Door Holders
Constructed of sturdy 16-guage steel, the SIGA-DG Smoke Detector Guard is designed
& Relays
SIGA-PS smoke detectors from damage or tampering. The advanced louver system allows
smoke detectors to be installed at their listed spacing and has no effect on operating sensitivity.
15
iO Series
SUBMIT
Intelligent Initiating Devices
Intelligent Control
Signature Series
iO Series
Input/Output Modules
Application Module
Waterflow Switches Waterflow/Tamper Module
Class A indicating and initiating circuits, Universal Class A/B
two-wire smoke detectors Module
Class B Input Module
Signature Series intelligent
Class B Initiating Circuits:
Monitor Module
input/output modules feature
Door Closers, Fans, Dampers multiple user-set personality
Control Relay Module
Telephone Power and Audible/Visual Signal
codes that define the module’s
Signal Module behavior.
Power Selector, Strobe Synchronization
Sounder Base power Reversal Relay Module
Fire Suppression Releasing Module
Fault detection Isolator Module
UIO Motherboard
MO
16
iO Series Intelligent Initiating Devices
SUBMIT
Initiating
SIGA-MAB
Devices
SIGA-UM Universal Class A/B Module (Two-gang standard mount) Data Sheet: 85001-0275
SIGA-MAB Universal Class A/B UIO (Plug-in) Module Data Sheet: 85001-0275
Notification
actual function of this module is determined by the “personality code” selected by the installer.
Appliances
A total of four personalities are available. SIGA-MCT2
SIGA-CT1 Single Input Module (One-gang standard mount) Data Sheet: 85001-0241
SIGA-CT1HT Single Input Module, high temperature rating (One-gang standard mount) Data Sheet: 85001-0241
SIGA-CT2 Dual Input Module (One-gang standard mount) Data Sheet: 85001-0241
SIGA-MCT2 Dual Input UIO (Plug-in) Module Data Sheet: 85001-0241
Hazardous Location
Synchronization Output Module
The Synchronization Output Module is an intelligent device that connects a supervised output
Devices
circuit to a 24 Vdc riser. The output wiring is monitored for open circuits and short circuits.
A short circuit will cause the fire alarm control panel to inhibit the activation of the audible/
visual signal circuit so the riser is not connected to the wiring fault. Upon command from the
Signature loop controller, the Auto-Sync Output Module connects the output circuit to the
riser input. The output circuit operates polarized audible and visual appliances that have an
adjustable resynchronizing feature.
SIGA-CC1S Synchronization Output Module (One-gang standard mount) Data Sheet: 85001-0543
SIGA-MCC1S Synchronization Output UIO (Plug-in) Module Data Sheet: 85001-0543
Door Holders
& Relays
17
iO Series
SUBMIT
Intelligent Initiating Devices
Intelligent Control
Signature Series
iO Series
Input/Output Modules
Signal Module
The Signal Module is used to connect, upon command from the loop controller, supervised
Class B signal or telephone circuits to their respective power inputs. Models are available with
one or two power inputs. These may be either polarized 24 Vdc to operate audible and visual
signal appliances, or 25 and 70Vrms to operate audio evacuation speakers and firefighter’s
Initiating
Devices
telephones. The actual function of this module is determined by the “personality code” selected
by the installer. A total of three personalities are available.
SIGA-CC1 Single Input Signal Module (Two-gang standard mount) Data Sheet: 85001-0237
SIGA-MCC1 Single Input Signal UIO (Plug-in) Module Data Sheet: 85001-0237
SIGA-CC2 Dual Input Signal Module (Two-gang standard mount) Data Sheet: 85001-0237
SIGA-MCC2 Dual Input Signal UIO (Plug-in) Module Data Sheet: 85001-0237
SIGA-CC2A Dual Input Signal Module with Class A Operation (Two-gang mount) Data Sheet: 85001-0609
SIGA-MCC2A Dual Input Signal UIO with Class A Operation (Plug-in) Module Data Sheet: 85001-0609
SIGA-CRR Polarity Reversal Relay Module (One-gang standard mount) Data Sheet: 85001-0239
SIGA-MCRR Polarity Reversal Relay UIO (Plug-in) Module Data Sheet: 85001-0239
SIGA-RM1 Riser Monitor Module (One-gang standard mount) Data Sheet: 85001-0535
SIGA-MRM1 Riser UIO (Plug-in) Module Data Sheet: 85001-0535
18
iO Series Intelligent Initiating Devices
SUBMIT
Input/Output Module
The Input/Output Module is an intelligent device that provides the following
modes of operation:
• Output with monitor input
Initiating
• Input/programmable output
Devices
• Input/direct output
SIGA-IO Input/Output Module (One-gang standard mount) Data Sheet: 85001-0533
SIGA-MIO Input/Output UIO (Plug-in) Module Data Sheet: 85001-0533
Waterflow/Tamper Module
The SIGA-WTM Waterflow/Tamper Module is a two circuit intelligent module. Circuit 1 is for Class
B normally-open waterflow alarm switches. When the input contact is closed for approximately 16
seconds, an “alarm” signal is sent to the loop controller. Circuit 2 is for Class B normally open dry
contact supervisory and tamper switches. When the input contact is closed, an “active” signal is
Notification
Appliances
sent to the loop controller. Conditions on both circuits are latched at the module.
SIGA-WTM Waterflow/Tamper Module (One-gang standard mount) Data Sheet: 85001-0297
Isolator Module
The SIGA-IM Isolator Module is an intelligent device that allows part of the Signature data loop
to continue operating in the event of a short circuit. The module can be wired into a Class
A data loop at any point. A maximum of 64 isolator modules can be installed on one circuit.
If a fault occurs, the isolator cuts power to all devices beyond the isolator on the loop. Once
Hazardous Location
activated, the line fault isolator continuously checks the faulted side of the loop to determine
if the short still exists. When the fault is cleared, the module automatically restores the entire
data loop to its normal condition.
Devices
SIGA-IM Fault Isolator Module (Two-gang standard mount) Data Sheet: 85001-0271
Monitor Module
The SIGA-MM1 is a single-circuit intelligent module that includes a Class B normally-open dry
contact. This is used for monitoring input from devices such as fans, dampers, and doors.
When the input contact is closed, an “active” signal is sent to the loop controller. The active
condition is not latched at the module.
SIGA-MM1 Monitor Module (One-gang standard mount) Data Sheet: 85001-0297
Door Holders
& Relays
19
iO Series
SUBMIT
Intelligent Initiating Devices
Intelligent Control
Signature Series
iO Series
Input/Output Modules
modules plug into the board and are held securely in place with captive machine
screws. All field wiring connects to terminal blocks on the motherboard, which
I O 6R permits rapid removal and replacement of modules for troubleshooting.
U
The SIGA-UIO2R provides mounting and wiring terminations for up to two UIO
modules, and the SIGA-UIO6R provides mounting and wiring terminations for up
to six UIO modules. Both motherboards feature a riser #1 input and a riser #2 input
2R
UIO bus. Jumpers on riser #1 input (between modules), facilitate sharing a single riser
among more than one module. This significantly reduces wiring requirements. Re-
moving the jumpers provides Module Input/Output Wiring
MFC-A will hold one UIO2R motherboard or one Individual Riser 1 Input to each SIGA-UIO module
SIGA-UIO2R Universal Input/Output Module Board with Riser Inputs — 2 Module Positions Data Sheet: 85001-0365
SIGA-UIO6R Universal Input/Output Module Board with Riser Inputs — 6 Module Positions Data Sheet: 85001-0365
SIGA-UIO6 Universal Input/Output Module Board — 6 Module Positions Data Sheet: 85001-0365
Related Equipment
MFC-A Multi-function Cabinet (for UIO and Releasing modules)
27193-11 Surface Mount Box - Red, One-gang
27193-16 Surface Mount Box - White, One-gang
27193-21 Surface Mount Box - Red, Two-gang
27193-26 Surface Mount Box - White, Two-gang
235196P Bi-polar Transient Protector (use with all Signal Modules)
SIGA-MP1 Signature Module Mounting Plate, 1 footprint
SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint
SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint
20
iO Series Intelligent Initiating Devices
SUBMIT
Releasing Module
The Signature Series Releasing Module (SIGA-REL) is an analog addressable
module that works with fire suppression systems designed to release extinguish-
ing gas such as Halon. Its primary function is the control of sprinkler pre-action
routines and the initiation of suppression system deluge functions. The module
Initiating
Devices
is easily configured in the field and offers a wide range of options that prevent
the unnecessary release of extinguishing agent.
The SIGA-REL is a network component consisting of:
• Two supervised release circuits
• Two supervised pre-release circuits
• One supervised manual
release input circuit Abort
First alarm output
Notification
Appliances
The releasing module includes a built-in timer that inhibits the deluge Signature data out +
_
DS2
function during the pre-action routine. One of four pre-action routines, DS4 DS5 DS3
enclosure. Each MFC-A will hold one SIGA-REL. Pre-release CCT1 (pulsed 15/60)
RELA-EOL RELA-EOL
tions, abort switches and service switches. Together with the SIGA- 4 4
Hazardous Location
SIGA-REL Analog addressable releasing module Data Sheet: 85001-0531
RELA-ABT Abort station Data Sheet: 85001-0531
Devices
RELA-SRV Service disconnect station Data Sheet: 85001-0531
276A-REL Manual releasing station (single-action) Data Sheet: 85001-0531
278A-REL Manual releasing station (double-action) Data Sheet: 85001-0531
RELA-EOL Polarized end-of-line relay Data Sheet: 85001-0531
Door Holders
& Relays
21
iO Series
SUBMIT
Intelligent Initiating Devices
NORM
AL
LIF
T
Intelligent Control
Signature Series
iO Series
TB2
SIGA-270 series manual pull stations are made from Red LED
(Alarm/Active)
4 3 2 1
Green LED
(Normal)
or Previous Device
SIGA-270 One Stage Fire Alarm Station, English Markings Data Sheet: 85001-0279
SIGA-270P Two Stage (Pre-signal) Fire Alarm Station, English Markings Data Sheet: 85001-0279
276-K2 GA Key — for pre-signal station Data Sheet: 85001-0279
270-GLR 20 Break-rods — for SIGA-270 series Data Sheet: 85001-0279
276B-RSB Surface Mount Box, Red — for SIGA-270 series Data Sheet: 85001-0279
REAR VIEW
8 7
red LEXAN. To initiate an alarm, first lift the upper door, TB1
SIGA-278 Double Action (One Stage) Fire Alarm Station, English Markings Data Sheet: 85001-0279
276B-RSB Surface Mount Box, Red — for SIGA-278 series Data Sheet: 85001-0279
276-GLR 20 Break-rods — for SIGA-278 series Data Sheet: 85001-0279
Stopper II
This unique device helps prevent false alarms without restricting legitimate ones. It consists of a tamper-
proof clear LEXAN polycarbonate shield and frame that fits easily over manual pull stations. When lifted,
it sounds a piercing warning horn.
STI-1100 (Flush) STI-1130 (Surface) Stopper II with Horn Data Sheet: 85001-0491
STI-1200 (Flush) STI-1230 (Surface) Stopper II without Horn Data Sheet: 85001-0491
STI-3100 (2" Spacer) STI-3004 (Conduit Insert) Spacers Data Sheet: 85001-0491
STI-3002 (Gasket) STI-3003 (Conduit Gasket) Weatherproofing Data Sheet: 85001-0491
22
iO Series N o t i fi c a t i o n A p p l i a n c e s
Notification
Harsh Environment Signals p. 30
Audible Signals p. 31
Appliances
Accessories p. 33
Audio Notification System p. 32
Class B wiring
iO500 control panels come equipped with four notification Class B wiring
Notification
NAC1 -
Appliances
appliance circuits that can be wired to provide four Class NAC1 -
+ +
NAC1+ + +
NAC1+
- -
B NACs or two Class A NACs. The iO64 comes with two NAC2 - - - EOLR
NAC2 -
+ + EOLR
Class B NACs. These may be configured for Class A op- NAC2+ +- +-
NAC2+
TB2 - -
eration with the optional SA-CLA Class A Module installed. TB2 NAC3 -
NAC3 -
+ +
iO Series NACs may be individually configured for continu- NAC3+ + +
NAC3+ - - EOLR
ous, temporal, synchronized, and coded output.
NAC4 -
NAC4 -
+- +- EOLR
NAC4+ + +
NAC4+ - -
iO Series NACs are configurable to fully support the advanced - -
Hazardous Location
TB6
TB6
signaling technology of Edwards Genesis and Enhanced
Class A wiring
Class A wiring-
Integrity notification appliances. These devices offer precision
Devices
NAC1
NAC1 -
+ +
synchronization of strobes to UL 1971 standards. For Genesis NAC1+ + +
NAC1+ - -
NAC2 - - -
devices, enabling this feature allows connected horns to be NAC2 - + +
NAC2+ +
- -+
silenced while strobes on the same two-wire circuit continue TB2
NAC2+
- -
TB2 -
to flash until the panel is reset. -
+
+
-
-
+
+
TB6
Door Holders
TB6
& Relays
23
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s
Genesis Visual
Intelligent Control
iO Series
Application flexibility
Whether you’re designing for a new landmark structure,
or simply retrofitting a local strip mall, competitively-
Outdoor Speakers, Speaker-Strobes,
p. 28 priced Genesis signals bring value, good looks, and
installation flexibility to every application. Contact Ed-
wards today to learn how your signal solutions can be
the model of discretion.
24
iO Series N o t i fi c a t i o n A p p l i a n c e s
SUBMIT
Genesis Series Wall Models
Strobes,
Horns & Chimes
Genesis signals feature textured housings in architecturally neutral white or
traditional fire red. An ingenious iconographic symbol indicates the purpose
of the device. This universal symbol is code-compliant and is easily recog-
nized by all building occupants regardless of what language they speak.
models with “FIRE” and “ALERT” markings are also available.
Genesis strobes offer 15 to 110 candela output, which is selectable with a conveniently-located switch on the side of the
device. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent
unauthorized tampering. (Data Sheet 85001-0573)
White housing White housing Red housing Red housing Fire Alarm Appliances
no marking with “FIRE” no marking with “FIRE” (with “Running Man” icon)
G1-VM G1F-VM G1R-VM G1RF-VM Strobe only (15/30/75/110 cd)
G1F-V1575 G1RF-V1575 Strobe only (15/75 cd¹), 24 V
Genesis Horns and Horn-strobes reach output levels as high as 99 dB and features a unique multiple frequency tone that
Notification
Appliances
results in excellent wall penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-
coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB.
(Data Sheet 85001-0573)
White housing White housing Red housing Red housing Fire Alarm Appliances
no marking with “FIRE” no marking with “FIRE” (with “Running Man” icon)
G1-HD G1F-HD G1R-HD G1RF-HD Horn only (high/low dB)
G1-HDVM G1F-HDVM G1R-HDVM G1RF-HDVM Horn-strobe (15/30/75/110, high/low dB)
G1F-HDV1575 G1RF-HDV1575 Horn-strobe (15/75 cd¹, high/low dB), 24 V
G1-P G1F-P G1R-P G1RF-P Steady horn (not compatible with Signal Master)
Hazardous Location
Genesis chimes and chime-strobes produce a pleasing mellow tone. When steady (non-stroked) voltage is applied, the
chime automatically pulses at 60 strokes per minute, or may be field-configured for temporal output. When installed with a
GIM Signal Master Module, the chime may also be field-configured for coded operation, which enables the chime output
Devices
to match the rate that voltage is applied to the circuit. Chimes may be set for low dB output with a jumper cut that reduces
sound output by about 5 dB. (Data Sheet 85001-0574)
White housing Red housing Chimes and Chime-strobes
G1-CVM G1R-CVM Chime-strobe (15/30/75/110, high/low dB)
G1-C G1R-C Chime only (high/low dB)
Trim plates for wall horns, chimes, and strobes are ideal for covering openings left behind during retrofits.
White plate White plate Red plate Red plate White plateFire Trim Plates
no marking with “FIRE” no “FIRE” with “FIRE” with “ALERT”
Door Holders
G1T G1T-FIRE G1RT G1RT-FIRE G1WT-ALERT Trim plate for 2-gang or 4” boxes
& Relays
¹ 15/75 cd models provide fixed output. The 15 cd output component complies with UL1971. The 75 cd output component complies with UL 1638.
25
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s
Intelligent Control
Genesis Series Wall Models
Speakers,
iO Series
15
1
of the device. (Data Sheet 85001-0549)
Bottom View
Initiating
selectable with a conveniently-located switch on the bottom Candela and wattage settings remain clearly
of the device. visible even after final installation.
All speakers feature selectable ¼, ½, 1, or 2 watt operation. Multi-candela strobes feature selectable 15, 30, 75, or 110 cd output.
White housing White housing Red housing Red housing Fire Alarm Speakers
no marking with “FIRE” no marking with “FIRE” (with “Running Man” icon)
G4-S2 G4F-S2 G4R-S2 G4RF-S2 25 V Speaker
G4-S7 G4F-S7 G4R-S7 G4RF-S7 70 V Speaker
G4-S2VM G4F-S2VM G4R-S2VM G4RF-S2VM 25 V Speaker-strobe (15/30/75/110 cd settings)
G4-S7VM G4F-S7VM G4R-S7VM G4RF-S7VM 70 V Speaker-strobe (15/30/75/110 cd settings)
Notification
Appliances
GL1WN-TP (White) GL1RN-TP (Red) Trim Plate for four-inch square boxes Data Sheet 85001-0635
GL1WN-BB1G (White) GL1RN-BB1G (Red) One-gang surface box for GL Series Data Sheet 85001-0635
26
iO Series N o t i fi c a t i o n A p p l i a n c e s
SUBMIT
Genesis Series Ceiling or Wall Models
Speakers,
Horns, Strobes
Select
The Genesis line of multi-candela and multi-wattage ceiling sig- 15/30/75/95 Select
nals feature all the hallmarks that have made Genesis products a and 95/115/150/177 ¼, ½, 1, or 2
candela output! watt operation!
big hit with designers, engineers, building owners, and installers
everywhere. These signals are 30 per cent slimmer than compa-
Ceiling Strobes Data Sheet 85001-0557
rable signals on the market. They are compatible with standard
Ceiling Horn-strobes Data Sheet 85001-0559
4-inch (10 cm) square electrical boxes and don’t require exten-
Ceiling Speaker-strobes Data Sheet 85001-0556
sion rings or trim plates. These signals are also listed for wall Ceiling Speakers Data Sheet 85001-0556
mount applications.
White housing White housing Red housing All fire alarm appliances come
no marking with “FIRE” with “FIRE” with the “Running Man” Icon
GC-VM GCF-VM GCFR-VM Strobe, 15/30/75/110 (standard output) cd, selectable
GC-VMH GCF-VMH Strobe, 95/115/150/177 (high output) cd, selectable
GC-HDVM GCF-HDVM GCFR-HDVM Horn-strobe, 15/30/75/110 (standard output) cd, selectable
GC-HDVMH GCF-HDVMH Horn-strobe, 95/115/150/177 (high output) cd, selectable
GC-S2VM GCF-S2VM Speaker-strobe, 25 V, 15/30/75/110 cd selectable
GC-S2VMH GCF-S2VMH Speaker-strobe, 25 V, 95/115/150/177 cd selectable
Notification
Appliances
GC-S7VM GCF-S7VM GCFR-S7VM Speaker-strobe, 70 V, 15/30/75/110 cd selectable
GC-S7VMH GCF-S7VMH Speaker-strobe, 70 V, 95/115/150/177 cd selectable
GC-S2 GCF-S2 GCFR-S2 Speaker, 25 V
GC-S7 GCF-S7 GCFR-S7 Speaker, 70 V
All speakers feature selectable ¼, ½, 1, or 2 watt operation. All horns feature high or low dB output.
Multi-Candela Strobes feature 15, 30, 75, or 95 candela output. Multi High-Candela Strobes feature 95, 115, 150, or 177 candela output.
Hazardous Location
Low Frequency Horns & Strobes
Devices
G4LF Series notification appliances provide the benefits of Genesis life safety signals with
output suitable for sleeping areas and other applications requiring low frequency audible
tones. These high-performance appliances generate a crisp 520 Hz tone in the standard
3-3 temporal pattern. An optional setting configures the appliance for continuous audible
output — a critical feature for notification appliance circuits that are coded with a CDR-3
coder module. All G4LF appliances feature field-configurable high and low dB output set-
tings. Horn-Strobe models feature field-selectable 15, 30, or 75 cd output settings.
G4LFWN-HVM Horn-Strobe, 520 Hz, White Housing, No Marking, 15/30/75 cd Data Sheet 85001-0639
G4LFWF-HVM Horn-Strobe, 520 Hz, White Housing, FIRE Marking, 15/30/75 cd Data Sheet 85001-0639
Door Holders
G4LFRN-HVM Horn-Strobe, 520 Hz, Red Housing, No Marking, 15/30/75 cd Data Sheet 85001-0639
& Relays
G4LFRF-HVM Horn-Strobe, 520 Hz, Red Housing, FIRE Marking, 15/30/75 cd Data Sheet 85001-0639
G4LFWN-H Horn, 520 Hz, White Housing, No Marking Data Sheet 85001-0639
G4LFWF-H Horn, 520 Hz, White Housing, FIRE Marking Data Sheet 85001-0639
G4LFRN-H Horn, 520 Hz, Red Housing, No Marking Data Sheet 85001-0639
G4LFRF-H Horn, 520 Hz, Red Housing, FIRE Marking Data Sheet 85001-0639
27
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s
Intelligent Control
Genesis Series
Genesis Series Wall or Ceiling Models
iO Series
Outdoor Speakers
and Speaker-Strobes
Genesis WG4 Series speakers and speaker-strobes are among the most
versatile emergency signals of their kind. NEMA 4X rated for indoor or
outdoor use, they are suitable for a wide range of wet and harsh environ-
ments with a listed operating temperature range of as low as -31°F to as
high as 151°F (-35°C to 66°C).
Initiating
Devices
Refer to Data Sheet 85001-0627 -- Genesis Outdoor Speakers and Strobes for details.
S1:
vice after the cover is replaced. Genesis speaker- wattage
strobes may also be configured for temporal flash.
This battery-saving feature is intended for private S2: JP1: Strobe temporal
mode signaling only. To set the device for temporal Candela mode selection
flash, snip the jumper at JP1.
White housing White housing Red housing Red housing Fire Alarm Speakers
no marking with “FIRE” no marking with “FIRE”
WG4WN-S WG4WF-S WG4RN-S WG4RF-S 25/70 V Speaker
WG4WN-SVMC WG4WF-SVMC WG4RN-SVMC WG4RF-SVMC 25/70 V Speaker-strobe (15/29/70/87 cd)
WG4WF-SVMHC WG4RN-SVMHC WG4RF-SVMHC 25/70 V Speaker-strobe (102/123/147/161 cd)
Trim skirts
WG4WTS (white) WG4RTS (red) Surface Skirt for Genesis WG4 appliance family.
28
iO Series N o t i fi c a t i o n A p p l i a n c e s
SUBMIT
Genesis SeriesWall or Ceiling Models
Outdoor Horns
and Horn-Strobes
Genesis WG4 Series horns and horn-strobes are among the most versatile emer-
gency signals of their kind. NEMA 4X rated for indoor or outdoor use, they are suit-
able for a wide range of wet and harsh environments with a listed operating tem-
perature range of as low as -31°F to as high as 151°F (-35°C to 66°C).
Refer to Data Sheet 85001-0628 -- Genesis Outdoor Horns and Strobes for details.
Signal In — Signal Out —
Notification
Appliances
—/+ designations indicate the signal polarity
required to activate the device.
Light Output
Hazardous Location
Standard Candela Horn-strobes High Candela Horn-strobes
Strobe Switch Position Strobe Switch Position
Standard/rating Standard/rating
D C B A D C B A
UL 1971 Indoor 15 cd 29 cd 70 cd 87 cd UL 1971 Indoor 102cd 123cd 147cd 161cd
Devices
UL 1638 Outdoor @ -35°C 6 cd 12 cd 28 cd 35 cd UL 1638 Outdoor @ -35°C 41cd 50 cd 60 cd 65 cd
CAN/ULC-S526 Outdoor @ -40°C 1 cd 3 cd 8 cd 10 cd CAN/ULC-S526 Outdoor @ -40°C 11 cd 14 cd 17 cd 18 cd
White housing White housing Red housing Red housing Outdoor Fire Alarm Appliances
no marking with “FIRE” no marking with “FIRE”
WG4WN-H WG4WF-H WG4RN-H WG4RF-H Horn Only
WG4WN-HVMC WG4WF-HVMC WG4RN-HVMC WG4RF-HVMC Horn-Strobe, standard cd output
WG4WN-HVMHC WG4WF-HVMHC WG4RN-HVMHC WG4RF-HVMHC Horn Only, high cd output
Door Holders
& Relays
29
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s
Harsh Environment
North American
2-gang electrical box
Mounting Plate
iO Series
Signals Housing
Surface Box (optional)
All Enhanced Integrity devices are UL 1971 listed for both wall and ceiling orien- First Device
tation. Enhanced Integrity strobes meet the latest UL1971 synchronization re- - Horn/Strobe Horn/Strobe
To Fire Alarm
Control Panel H+ H+
quirements when used with the G1M Signal Master. Integrity devices are shipped Signal Circuit H-
S+
H-
S+
+
with wall mount style “FIRE” lens markings. Other lens markings are available.
S- S- To Next Device
or EOL Resistor
-
+
Re-entrant speakers feature a sealed, high efficiency compression driver that’s both weatherproof and
vermin proof. This makes them ideal for public places and outdoor areas such as parking garages
and transport terminals. All Integrity speakers include a DC Blocking Capacitor that permits electrical
supervision of the audio distribution circuit. Models for 25Vrms and 70Vrms circuits are available.
30
iO Series N o t i fi c a t i o n A p p l i a n c e s
SUBMIT
Audible Signals
Notification
Appliances
Fire Alarm Bells
Edwards fire alarm bells are of the underdome type with heavy-duty mechanisms. Gongs
are made of selected alloy steel to generate the loud, resonant tones. For weatherproof ap-
plication, optional surface weatherproof backboxes are available.
323D-10AW (Grey) 323D-10AR (Red) 10-inch Single Stroke, Diode — 20-24Vdc Data Sheet: 85001-0333
439D-6AW (Grey) 439D-6AR (Red) 6-inch Vibrating, Diode — 20-24Vdc Data Sheet: 85001-0333
439D-10AW (Grey) 439D-10AR (Red) 10-inch Vibrating, Diode — 20-24Vdc Data Sheet: 85001-0333
Hazardous Location
Multiple Tone Signal
Devices
The 5530MD-24AW is a weatherproof heavy-duty industrial, tone-selectable, signaling de-
vice capable of producing volume-controlled, high-decibel tones. It uses a microprocessor
circuit to create 27 distinctive tones. A single tone may be selected by setting a miniature
dip switch within the unit.
5530MD-24AW 27-Tone Selectable Signal — 24Vdc Data Sheet: 85001-0415
Multi-purpose Loudspeaker
Door Holders
The HPSA15 loudspeaker is a high-efficiency double re-entrant loudspeaker that operates within a
nominal frequency response range of 400-14,000 Hz, and provides audible output of 120 dB (peak
& Relays
at one meter) at the rated power level. It includes a versatile, three-way, 25/70.7 V line transformer
that meets a variety of distributed system needs. The transformer is adjustable by means of a
convenient seven-position, watts/impedance selection switch.
HPSA15R2570 15-watt loudspeaker, red Data Sheet: 85001-0591
HPSA15G2570 15-watt loudspeaker, gray Data Sheet: 85001-0591
31
iO Series
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s
Audio Notification System
Intelligent Control
iO Series
Built-in Power
Transformer The ANS series of products from are high-performance audio notification
systems that provide voice evacuation capability that meet the Emergency
TB1 1 2 3 4 5 6 7 8
TB2
Voice Alarm requirements of NFPA 72 for UL listed fire alarm applica-
tions. ANS panels, which are available in 25, 50, or 100 Watt models,
11
1 TB3
10
2
9
3
8
4
6
Devices
5
7
Trouble 4
supervisory interface.
8
3
Normal 2
1
Alarm
Panels include DMR, temporal pattern, standard message, microphone, power supply and battery charger.
Appliances
ANS25MDG (Grey Cabinet) ANS25MDR (Red Cabinet) 25 Watt Audio Notification Panel. Data Sheet 85001-0587
ANS50MDG (Grey Cabinet) ANS50MDR (Red Cabinet) 50 Watt Audio Notification Panel. Data Sheet 85001-0587
ANS100MDG (Grey Cab) ANS100MDR (Red Cabinet) 100 Watt Audio Notification Panel. Data Sheet 85001-0587
32
iO Series N o t i fi c a t i o n A p p l i a n c e s
SUBMIT
Accessories
Bell/Strobe Plate
The bell/strobe plate is ideal for renovation and retrofit projects, and new construction. It
is equipped with an Edwards self-synchronizing strobe and is designed to allow on-site
mounting of the 439 series Vibrating Bell, providing instant conversion to Bell/Strobe
audible/visual signal appliances. The strobe is designed for 20 to 24Vdc operation and
must be connected to signal circuits which output a constant (not pulsed) voltage. A
diode is used to allow full signal circuit supervision.
403-5A-R (15 cd) 403-7A-R (15/75 cd) 403-3A-R (30 cd) 403-8A-R (110 cd) Data Sheet: 85001-0441
Notification
Appliances
LKW-4 (Wall orientation) LKC-4 (Ceiling orientation) “SMOKE”
LKW-5 (Wall orientation) LKC-5 (Ceiling orientation) “HALON”
LKW-6 (Wall orientation) LKC-6 (Ceiling orientation) “CO2”
LKW-7 (Wall orientation) LKC-7 (Ceiling orientation) “EMERGENCY”
LKW-8 (Wall orientation) LKC-8 (Ceiling orientation) “ALARM”
LKW-9 (Wall orientation) LKC-9 (Ceiling orientation) “FUEGO”
LKW-10 (Wall orientation) LKC-10 (Ceiling orientation) “ALERT”
Hazardous Location
Mounting Accessories
Devices
Integrity Temporal Horn, Horn/strobe Genesis Signals
757A-SB Surface Box, Red, Indoor 27193-11 Horn-strobe Surface Box, Red, Indoor
757A-SBW Surface Box, White, Indoor 27193-16 Horn-strobe Surface Box, White, Indoor
757A-WB Weatherproof Box, Red, Surface G4RB Speaker Surface Box, Red, Indoor
757A-WBW Weatherproof Box, White, Surface G4B Speaker Surface Box, White, Indoor
G4ERB G4 Dual-strobe Format Surface box, Red
Integrity Speakers, Speaker/strobes G4EWB G4 Dual-strobe Format Surface box, White
960A-4SF Flush Box, Indoor
757A-SB Surface Box, Red, Indoor Horn/siren Combination
757A-SBW Surface Box, White, Indoor 349 Weatherproof Backbox
Integrity Re-entrant speakers, Speaker/strobes Fire Alarm Bells and CS-405 Series
960A-4SF Flush Box, Indoor 449 Weatherproof Backbox
757A-SB Surface Box, Red, Indoor
Door Holders
33
Notification Initiating iO Series
Appliances Devices Intelligent Control
34
SUBMIT
N o t i fi c a t i o n A p p l i a n c e s
iO Series
iO Series Hazardous Location Devices
Hazardous Location Devices
Initiating Devices p. 36
Hazardous
Notification Appliances p. 37
Location Devices
Edwards hazardous location devices provide reliable life safety protection and emergency signaling in areas where
atmospheres could become harsh or explosive. All hazardous location devices are UL rated under the full range of
classifications set out in the National Electrical Code.
The following classification definitions are an interpretive summary based on the 1996 edition of the National Elec-
trical Code (NEC, NFPA 70). Refer to the latest editions of NFPA 497M, NFPA 70 and the UL Hazardous Location
Equipment Directory for current and more detailed information. For more information on NEMA classifications, refer
to NEMA Standards Publication No. 250.
Classes Divisions
The Location Classes are broken down by the NFPA into
Class I - Hazardous Gases. Class I locations are areas in which flam- Divisions 1 and 2, defining different levels of risk. In general,
mable gases or vapors are or may be present in the air in quantities the risk of there being a hazardous presence of flammable/
sufficient to produce explosive or ignitable mixtures. combustible/ignitable materials is higher for Division 1 than
Typical Class I Hazardous Areas for Division 2. The specifics differ between the three classes
• Spray painting and finishing areas (I, II and III). Equipment suitable for Division 1 is also suitable
• Utility gas plants for Division 2 locations.
• Petroleum refining production plants
• Petroleum dispensing locations
• Dry cleaning facilities
Groups
Class I and II locations are divided by the NFPA into Group
• Dip tanks containing combustibles or flammable liquids
designations identifying specific gases, vapors and dusts by
• Plant facilities extracting solvents
characteristic similarities that relate to specific equipment
• Inhalation anesthetics areas
construction requirements. Class III locations are not divided
• Process facilities manufacturing pyroxylin type plastics
into separate group designations.
Class II - Hazardous Dusts. Class II locations represent areas that are
hazardous due to the presence of combustible dust. Class I Groups
Group A. Atmospheres containing acetylene.
Hazardous Location
Typical Class II Hazardous Areas
• Flour mills Group B. Atmospheres containing hydrogen, fuel and
• Feed mills combustible process gases containing more than 30 percent
• Grain elevators and grain handling facilities hydrogen by volume, or gases or vapors of equivalent hazard
• Aluminum manufacturing and storage areas such as butadiene, ethylene oxide, propylene oxide, and
Devices
• Magnesium manufacturing and storage areas acrolein.
• Coal preparation and handling facilities
• Starch manufacturing and storage areas Group C. Atmospheres such as ethyl ether, ethylene, or
• Confectionery plants other gases or vapors of equivalent hazard.
• Pulverizer sugar and cocoa manufacturing, and storage plants
Group D. Atmospheres containing acetone, ammonia,
• Spice grinding and storage plants
benzene, butane, cyclopropane, ethanol, gasoline, hexane,
Class III - Hazardous Fibers. Class III locations have easily ignitable methanol, methane, natural gas, naphtha (petroleum), pro-
fibers or flyings present, but not likely to be suspended in air in quantities pane, or gases or vapors of equivalent hazard.
sufficient to produce ignitable mixtures in the atmosphere.
Class II Groups
Typical Class III Hazardous Areas
Group E. Atmospheres containing combustible metal dusts,
• Textile mills
including aluminum, magnesium, and their commercial
• Woodworking plants*
alloys, or other combustible dusts whose particle size, abra-
Door Holders
• Furniture manufacturers*
siveness and conductivity present similar hazards in the use
• Cotton gins
& Relays
of electrical equipment.
• Cotton seed milling plants
• Flax plants Group F. Atmospheres containing combustible carbona-
• Carpet manufacturers ceous dusts, including carbon black, charcoal, coal, or dusts
that have been sensitized by other materials so that they
* Except if wood flour (dust), which is Class II Group G, is present
present an explosion hazard.
35
iO Series
SUBMIT
Hazardous Location Devices
Initiating Devices
Intelligent Control
iO Series
302-AW-135 All-weather Heat Detector - Vertical Mounting FM & UL, 135 °F (57.2 °C) Data Sheet: 85001-0589
302-AW-194 All-weather Heat Detector - Vertical Mounting FM & UL, 194°F (90 °C) Data Sheet: 85001-0589
Notification
Appliances
302-ET-135 All-weather Heat Detector - Vertical, Box Mount (½" NPT), FM & UL, 135 °F (57.2 °C) Data Sheet: 85001-0589
302-ET-194 All-weather Heat Detector - Vertical, Box Mount (½" NPT), FM & UL, 194°F (90 °C) Data Sheet: 85001-0589
302-EPM-135 Heat Detector - Explosionproof Mounting UL (Not FM approved), 135 °F (57.2 °C) Data Sheet: 85001-0589
302-EPM-194 Heat Detector - Explosionproof Mounting UL (not FM approved), 194°F (90 °C) Data Sheet: 85001-0589
AP-P Adaptor plate for mounting 302 and 302-AW to any 3" box or 4" octagon outlet box Data Sheet: 85001-0589
STONCO27 3 ½" Weatherproof, round backbox and cover Data Sheet: 85001-0589
JALX11 Explosion proof outlet body with cover - Killark Data Sheet: 85001-0589
Hazardous Location
MPSR Series explosionproof/weatherproof manual pull stations are noncoded fire alarm
stations solidly constructed of die-cast material. They are rated for Class I Group B (hy-
drogen) C & D, Class II Groups E. F, G, Class III environments, and are rated NEMA 4X for
outdoor use. Key and screw reset models feature terminal connections and come complete
with backbox.
Hex Screw Reset Cat 45 Key Reset Manual Stations Data Sheet: 85001-0588
MPSR1-DHTWX-GE MPSR1-D45WX-GE Explosionproof Single-action, SPST with backbox.
MPSR1-SHTW-GE MPSR1-S45W-GE Weatherproof Single-action, SPST with backbox.
MPSR1-DHTW-GE MPSR1-D45W-GE Weatherproof Single-action, DPDT with backbox.
MPSR2-SHTW-GE MPSR2-S45W-GE Weatherproof Double-action, SPST with backbox.
MPSR2-DHTW-GE MPSR2-D45W-GE Weatherproof Double-action, DPDT with backbox.
MPSR2-SHTW-GE-NYW MPSR2-S45W-GE-NYW Weatherproof Double-action, SPST with backbox, NYC white stripe.
For French markings add -F to the suffix of the model number. For bilinguial French/English markings add -B to the suffix of the model number.
36
iO Series Hazardous Location Devices
SUBMIT
Notification Appliances
Hazardous Location
Hazardous Location Horns
• Class I groups B, C and D locations • Class III hazardous locations, for Divisions 1 and 2
Devices
• Class II groups E, F and G locations
888D and 889D hazardous location horns are diode-polarized, heavy duty, high decibel vibrating horns intended for
use in life safety systems in hazardous (classified) locations. These horns may be mounted to any solid surface using
two bolts. Each unit is supplied with a sealing fitting for a 3/4 inch -14 National Pipe Taper (NPT) nipple, and wire leads
for the electrical connection to the life safety system notification appliance circuit.
888D-N5 (120 Vac) 889D-AW (24 Vdc) Horn – 120 Vac Data Sheet 85001-0397
Door Holders
& Relays
37
iO Series
SUBMIT
Door Holders & Relays
Intelligent Control
iO Series
Door Holders
Electromagnetic Door Holders
Edwards electromagnetic door holders keep doors open until signaled by the
fire alarm system, a heat detector, a smoke detector, or an electrical switch.
Door holders should be installed wherever doors may be effectively used to
confine smoke and fire, or where the release of a self-closing door from a
remote location is required. Fail-safe operation is an inherent feature of these
door holders. If power fails, doors are released automatically, but may be
24 Vac 60 Hz opened or closed manually at any time. All units are free of moving parts, are
Initiating
Devices
24 Vdc self-contained, and require no maintenance. Door holders have a holding force
120 Vac 60 Hz of approximately 15-25 Lbf (66-111N).
1501-AQN5 (Single Door) 1502-AQN5 (Double Door) Floor Mounted Data Sheet 85001-0421
1504-AQN5 (Long Catch Plate) 1505-AQN5 (Short Catch Plate) Flush Wall Mounted Data Sheet 85001-0421
1508-AQN5 (Surface) 1505-AQN9 (Completely flush) Wall Mounted Data Sheet 85001-0421
1500-1 (1.5” Extension) 1500-2 (2.5” Extension) Catch Plate Data Sheet 85001-0421
1500-7 (5.25 to 7.5” Extension) 1500-12 (7.5 to 12” Extension) Catch Plate Data Sheet 85001-0421
CS2595-5 (short) CS2598-5 (long) Replacement Armature Data Sheet 85001-0421
Notification
Appliances
Relays
Four-Voltage SPDT/DPDT Control Relays
MR Series multi-voltage control relays are ideal for applications where local contacts are
required for system status, remote contacts, or for control of electrical loads and general pur-
pose switching. They are suitable for use with HVAC temperature control, fire alarm, security,
energy management, and lighting control systems. Relays provide 10-Amp contacts, which
Hazardous Location
may be operated by one of four input control voltages. Each relay position contains a red
LED that indicates the relay coil is energized. Relays may be snapped apart from a standard
four-module assembly and used independently.
Devices
MR-101/T (with mounting hardware) MR-101/C (in metal enclosure) Single SPDT relay Data Sheet 270062
MR-104/T (with mounting hardware) MR-104/C (in metal enclosure) 4-position SPDT relay Data Sheet 270062
MR-201/T (with mounting hardware) MR-201/C (in metal enclosure) Single DPDT relay Data Sheet 270062
MR-204/T (with mounting hardware) MR-204/C (in metal enclosure) 4-position DPDT relay Data Sheet 270062
MR-199X-13 (relay only) MR-199X-13/C (in metal enclosure) Power Relay — 24 VDC Data Sheet 270065
MR-199AX-14 (relay only) MR-199AX-14/C (in metal enclosure) Power Relay — 120 VDC Data Sheet 270065
38
iO Series Door Holders & Relays
SUBMIT
SPDT Relays
Single-pull/double-throw relays are ideal for applications where local or remote con-
tacts are required for control of electrical loads. They are suitable for use with HVAC,
temperature control, fire alarm, security, energy management, and lighting control
systems. Each relay position contains a high-intensity LED which, when illuminated,
indicates the relay coil is energized. Individual relay circuits may be snapped apart
from standard four- or eight-position modules, and are also available in a single-circuit
configuration. The common power to each relay position is bussed on the printed
wiring board, which permits power to be connected only once per multi-position
module.
PAM-1 relays provide 10-Amp Form C contacts. The relay may be energized by one of three
input voltages: 24Vac, 24Vdc, or 115Vac. The PAM-1 may be mounted with double-sided
adhesive tape, a self-tapping screw, or loosely placed in a backbox.
39
Proven leadership. In 1872 when Robert Edwards Now we have access to the
uncompromised excellence.
40
Innovation, leadership,
and a rich tradition of excellence
Whether EST life safety systems are protecting the lives and livelihoods of the
people who make businesses run, or the lives entrusted to the care of public
institutions; whether they’re charged with protecting the guests of the world’s
finest hotels, or preserving irreplaceable artifacts that bring history to life; EST
stands alone as the brand closely associated with some of the most important
and far-reaching developments in the life safety industry today.
Together these strengths set EST installations apart, and have earned this
brand a special place among life safety and security solutions available today.
Perhaps that’s why EST products and systems have become the choice of
building owners, architects and engineers around the globe. And why many of
the world’s most cherished landmarks are protected by Edwards products that
bear the EST mark. From the Bibliotheca Alexandrina Museum in Egypt, to the
modern-day sphinx at the Luxor Hotel in Las Vegas, professionals who design,
own and occupy the world’s most impressive structures have come to know
that the safest and most survivable solution today is an EST solution.
Contact us...
Email: edwards.fire@fs.utc.com
Web: www.est-fire.com See what’s possible now.
EST is an EDWARDS brand. Contact your EST Strategic
1016 Corporate Park Drive
Mebane, NC 27302
Partner today.
In Canada, contact Chubb Edwards...
Email: inquiries@chubbedwards.com
Web: www.chubbedwards.com
85005-0132 Issue 3