TECHNICAL SALES GUIDE ‐ 60 Hz 
 
 

 
DMS Saber Medium Series
 

 
Air Cooled Packaged Air Conditioners
 
          
 

 
12.5 to 28 TR ‐ (R407c) 
 
 
 
 
 
 
                    

 
 
 
 
 
                  
 

 
Medium Series – 2nd Generation 
 
 

“Includes YORK simplicity Controller”
   
 

         
 

      
 
Packaged Air Conditioners

CONTENTS

Description ........................................................................ 3 Cooling Performance Data (115ºF Ambient) ....... 13


Typical Unit Configuration .......................................... 3 Cooling Performance Data (125ºF Ambient) ....... 15
Features ............................................................................... 4 Fan Performance Data .................................................. 17
Options Available ............................................................ 5 Drive & Pulley Data....................................................... 18
Simplicity Controls......................................................... 5 Electrical Data ................................................................. 19
Selection Method ............................................................ 6 Dimensional Data ........................................................... 21
Product Data ..................................................................... 6 Wiring Diagram ............................................................... 24
Cooling Performance Data (85°F Ambient) ............ 7 Guide Specifications ...................................................... 25
Cooling Performance Data (95°F Ambient) .......... 9 Maintenance ...................................................................... 26
Cooling Performance Data (105°F Ambient) ...... 11

PRODUCT NOMENCLATURE

D M S D 150 C01 A 1 A 1 2

Product Category Product Generation


D = A/C,Single Package  2 = Second Generation

Product Identifier Field Installed Options


M = Std. Efficiency 1 = No Option Installed
2 = 9 Kw Electric Heater
Series Name       (for DMS‐150 only)
S = Saber       18 Kw Electric Heater
3 = 36 Kw Electric Heater
Double Skin 4 = Fresh Air Damper
Optional

Nominal Cooling Capacity Factory Installed Options


150 = 12.5 Tons A = No Option Installed
190 = 16.0 Tons B = Heresite Coating on
240 = 20.0 Tons         Condenser Coil
260 = 22.0 Tons C = Heresite Coating on
340 = 28.0 Tons         Evaporator Coil
D = 2"Aluminum Washable Filter
E = Cu / Cu on Condenser Coil
F = Cu / Cu on Evaporator Coil
Mode G = Disconnect Switch
C01 = Cooling ‐R407c H = Phase Monitor
I = BMS [Building Management System]
J = High Speed Drive
K = Low Speed Drive
L = UV Lamp
Motor Option M = Dirty Filter Switch
A = Standard Motor N = Low Ambient Kit
B = Over Size Motor O = 9 KW Heater
P = Smoke Detector
Q = 18 KW Heater
Power Supply R = 36 KW Heater
1 = 220 V /3 Ph / 60 Hz S = Mixing Box [Double Skin]
2 = 380‐400 V /3 Ph / 60 Hz T = Temperature Economizer [Double Skin]
3 = 460 V /3 Ph / 60 Hz U = Enthalpy Economizer [Double Skin]
V = Bag Filter 85% Effcy. [Double Skin]
W = Moisture Eliminator [Double Skin]
X = VFC for comp.[status on/off]
Y = Pressure Guages
Z = Fresh Air Damper
Packaged Air Conditioners

DESCRIPTION

Models DMS 150,190,240,260 & 340 (12.5, 16, 20, 22 & 28 Nominal Tons)
YORK Saber Units are single package high efficiency rooftop air conditioner. All Models have
independent dual refrigerant circuits for efficient part load operation. DMS units are designed for roof
top, slab mounted ground level or on steel platform installation above floor or roof. A wide range of
factory mounted options and field installed accessories make the saber units suitable for almost every
application

YORK Saber units are designed to operate satisfactorily in wide range of ambient temperatures from
125°F (52°C) down to 50°F (10°C) as standard.

YORK Saber packaged air conditioners are rated in accordance with ARI 340/360

Standard units include:


Powder paint finish that meets ASTM B 117, 750 hour salt spray standard.
Two-stage cooling provided by dual independent refrigeration circuits with expansion valves, filter drier, high
and low pressure switches and freezestats.
High efficiency hermetic scroll compressors.
Side air discharge configuration.
Belt drive blower motor with variable pitch pulley.
Totally Enclosed Fan Cooled (TEFC) IP55 Evaporator fan motors with Class F Insulation.
Totally Enclosed Air Over (TEAO) IP55 Condenser fan motors with Class F Insulation.
Microprocessor based Simplicity TM control board.
Fresh air intake panel.
Copper tubes / Aluminum fins coils.
2 inch disposable filter with easy access.
Rigging holes in base rails for overhead lifting.
Single point power connection.
Complete factory package-tested, charged and wired.
1 year limited warranty on the complete unit and additional 4 years warranty on compressors.
TYPICAL UNIT CONFIGURATION

           

Page 3
 
Packaged Air Conditioners

FEATURES

Saber units are self-contained and assembled on full All Saber units are equipped with a control panel that
perimeter base rails with rigging holes in the four corners Includes all the necessary operating and safety controls
For overhead rigging. Every unit is completely piped, that are needed for reliable operation. Compressors are
wired, charged and tested at the factory to simplify the protected with internal thermal overload and fan motors
field installation and to provide years of dependable with external overload. Transformers and control circuits
operation. All models are suitable for horizontal duct are protected with fuses.
connections. The power supply can be routed into the
control box through a gland in the wiring panel on the The operation of the package units is masterminded by
front of the unit. the microprocessor based Simplicity™ control board
which provides both intelligent monitoring and easy
Compressors are scroll / reciprocating type of an diagnostics, as featured below
advanced design ensuring high Energy Efficiency Ratio,
less noise, less vibration and outstanding endurance. Anti Short Cycle Protection: To aid compressor life,
Crankcase heaters, internal pressure relief valve, internal an anti-short cycle delay is incorporated into the
compressor motor protection. standard controls. Compressor reliability is further
ensured by programmable minimum run times. For
Every refrigerant circuit includes an expansion valve, a testing, the anti short cycle delay can be temporarily
liquid line filter-drier, a discharge line high pressure overridden with the push of a button.
switch and suction line freezestat and low pressure switch
to protect all system components. Fan Delays: Fan on and fan off delays are fully
Programmable. Furthermore, the heating and cooling
Each supply air blower is equipped with a belt drive that Fan delay times are independent of one another. All
can be adjusted to meet the exact requirements of the units are programmed with default values based upon
application. A high or low static drive option is available their configuration of cooling and heating.
for applications with a higher or lower airflow and / or
static pressure requirement. All evaporator blower motors Safety Monitoring: High flow pressure switches and
are weatherproof TEFC IP55 with Class F insulation. suction line freezestats are supplied on all units to
protect against loss of charge and the occurrence of
A fixed outdoor air intake panel designed for 25% fresh coil frosting. The control board monitors the high and
air is available as standard. Fresh air dampers are optional low pressure switches and the freezestats. The unit
for field / factory installation. control board will alarm on compressor lockouts and
repeated limit switch trips on electric heat units.
Condenser fans are propeller type of heavy duty
construction, dynamically balanced and suitable for Nuisance Trip Protection: To prevent nuisance
operate up to 80°C ambient. Fans are driven by TEAO Trouble calls, the control board uses a “three times,
IP55 motors with Class F insulation. The fan blade pitch you’re out” philosophy. The high and low-pressure
Angle is designed for maximum airflow and minimum switches and the freezestats must trip three times
noise. within two hours before the unit control board will
lock out the associated compressor.
The evaporator and condenser coils are constructed of
seamless internally enhanced copper tubes which are On Board Diagnostics: Each alarm will energize a
mechanically bonded to aluminum fins. Heat Exchangers trouble light on the thermostat, if so equipped, and
are tested up to a pressure of 250 psig (evaporator) and Flash an alarm code on the control board LED. Each
450 psig (condenser). high and low-pressure switch alarm as well as each
freezestat alarm has its own flash code. The control
A nonmetallic drain pan with bottom condensate removal board saves the five most recent alarms in memory,
ensures zero water retention and no corrosion and these alarms can be reviewed at any time.
That ensures indoor air quality (IAQ).
Nonvolatile Memory: Alarms and programmed
All units have long lasting powder paint cabinets with a values are retained through the loss of power.
robust 40 microns thick paint coating that meets ASTM-
B-117 standards and suitable for 750 hour salt spray test,
ensuring excellent resistance to corrosion in the harshest
conditions. The cabinet of all DMS is internally lined by
13mm Elastomeric insulation that minimize heat gain and
improves IAQ.

Page 4
Packaged Air Conditioners

OPTIONS AVAILABLE

Heresite Coated Evaporator and Condenser Coils Main Disconnect Switch (factory installed): Suitably
(factory installed): Coating is applied by spray for sized in accordance with the applicable electrical codes.
maximum corrosion protection.
Thermostat (field installed):For 3 /4stage cooling only a
Copper Tube And Copper Fin Evaporator And and 2 stage heating.
Condenser Coils (factory installed). BMS Controls: Yo rk’ s Saber series units offer factory
mounted BMS controls-consult your local sales office for
Filter Options: Standard units are shipped, installed details.
with 2” throw away filters. 2” washable aluminum
filters are offered as a factory installed option. Low Ambient Kit (factory installed) : For unit to work
satisfactorily down to 32°F (0°C)
Bag Filters (factory installed): Units can be supplied
with standard size bag filters, depth 22” and efficiency
Smoke Detectors for supply air & return air (factory
65%, 85% & 95%. For this option, add 1000 mm in installed): The smoke detectors stop operation of the
unit length. unit by interrupting power to the control board if smoke
is detected within the air compartment.
High And Low Speed Drive (factory installed) :
Includes a belt and blower pulley to upgrade or Ultra Violet Lamps: factory installed.
downgrade the blower performance.
Economizer (factory installed): Saber units offer an
Fresh Air Dampers: Manual or motorized optional factory installed economizer with low leak
dampers, single enthalpy and double enthalpy controls.
Electric Heaters: All electric heat models (heater When selecting this option, add 1,000 mm in unit length.
factory/field installed only) are wired for a single power
source and include a bank of nickel chromium elements
Dirty Filter Switch (factory installed): This kit
to be mounted at the discharge of the supply air blower
to provide a high velocity and uniform distribution of includes a differential pressure switch that energizes the
air across the heating elements. Every element is fully fault light on the unit thermostat, indicating that there is
protected against excessive current and temperature by An abnormally high pressure drop across the
high temperature thermal cut-out (HTIC). filters.

Phase Monitors ( factory installed): Design to


prevent unit damage, the phase monitor will shut the
unit down in an out-of phase condition.

Page 5
Packaged Air Conditioners

PRODUCT DATA - 60 Hz R-407c

SELECTION METHOD
1) and the 80° DB column on the right. The
The following steps illustrate the selection of a DMS Sensible capacity for the unit in this example is
Package Unit for a Total Capacity requirement of 230
MBh and an Airflow of 7,400 cfm. The unit operating 159.7 MBh.
parameters are:
Entering Air Temperature: 80/67°F (DB/WB) Step 3 Refer “Fan Performance Data” on page 17 to
Ambient Temperature: 95°F Fan External Static check the motor size and fan rpm. Scroll down
Pressure: 1.2 inch wg. the “1.2 inch wg ESP” column to the 7400 cfm
Step 1 Select the unit model by referring to “Cooling row for DMS 240. The fan speed is 1020 rpm
performance data” table for 95°F ambient on and fan power input 3.77 Kw. The white colour
page 9 Scroll down the “Total capacity” and of the box indicates that the standard 4.0 kW
“Entering Air WBT” columns until 240 MBh
(or a value close to it) is found at 67°FWB for motor is sufficient.
an airflow close to 7,400 cfm.
The selected model is DMS-240 giving total Step 4 To arrive at the correct drive set to be ordered with
capacity 234.5 MBh with the actual compressor the unit, refer “Drive & Pulley Data” on page 18
power input being 20.0 Kw. the fan rpm from step 3 to select the correct drive
set. The package unit in this example will required
Step 2 For the sensible capacity read the value at the a standard drive set.
intersection of the same row (as the WB in step

Model DMS 150 190 240 260 340

EER Btuh/W 7.7 8.2 8.9 9.9 7.8


Ratings @
ARI Capacity MBh( kW) 140.5 (41.2) 180.9 (53.0) 234.5 (68.7) 247.8 (72.6) 316.2 (92.7)
Conditions
Compressor
Power Input Hp ( kW) 19.6 (14.8) 23.4 ( 17.6 ) 26.6 (20.0) 25.8 ( 19.4) 44.9 (33.4)

Heating Option 1 MBh ( kW) 30.7( 9 ) & 61.4(18) 61.4 ( 18 ) 61.4 ( 18 ) 61.4 ( 18 ) 61.4 ( 18 )
Capacities
Option 2 MBh( kW) 122.8 ( 36 ) 122.8 ( 36 ) 122.8 ( 36 ) 122.8 ( 36 ) 122.8 ( 36 )

Model DMS 150 190 240 260 340


Tube - ( - ) Copper / Aluminum
Evaporator Louvered
Fins - ( - )
Coil
Area ft² ( m² ) 12.2 ( 1.1 ) 13.3 ( 1.2 ) 17.3 ( 1.6 ) 23.6 ( 2.2 ) 23.6 ( 2.2 )
Tube - ( - ) Copper / Aluminum
Condenser
Coil Fins - ( - ) Louvered
Area ft² ( m² ) 19 ( 1.8 ) 24 ( 2.2 ) 26.7 ( 2.5 ) 26.7 ( 2.5 ) 26.7 ( 2.5 )
Fan Type Forward Curved Centrifugal - DIDW
Fan Qty 1 1 1 1 1
Blower Fan
& Motor Motor Type - ( ) 4 Pole, Class F Insulation, Totally Enclosed Fan Cooled ,IP 55, 1700 rpm
std 4 (3) 4 (3) 5.5 (4) 5.5 (4) 7.5 ( 5.5 )
Motor hp ( kW )
Size xtd 5.5 (4) 5.5 (4) 7.5 ( 5.5 ) 7.5 ( 5.5 ) 10 ( 7.5 )
Type - ( - ) 4 Blade heavy duty Propeller Fan
Condenser Quantity # ( # ) 1 2 2 2 2
Fan & - ( - )
Motor
Motor Type 6 Pole, Class F Insulation, Totally Air Over ,IP 55, 1100 rpm
Motor size hp ( kW ) 2 ( 1.5 ) 3 ( 2.2 ) 3 ( 2.2 ) 3 ( 2.2 ) 3 ( 2.2 )
Quantity # ( # ) 1 2 2 2 2
T\SH - ( - ) Hermetic Scroll
Compressor
# of Comp’s # ( # ) 2 2 2 2 2
Type - ( - ) R-407c
Refrigerant No of Circuits - ( - ) 2 2 2 2 2
Charge lbs (kgs) 17.6 (8) 22 ( 10 ) 29.9 ( 13.6 ) 33 ( 15 ) 35.2 ( 16 )
Height inches (mm) 52.7 (1338) 51.2 (1300)
Dimensions Width inches (mm) 75.5 (1918) 89.8 (2281)
Length inches (mm) 80.0 (2032) 100.5 (2553)
24 x 24 x 2 inches Qty - - 3
Filters
24 x 20 x 2 inches Qty 2 4 3

Weights Basic Unit lbs (Kg) 1335 ( 607 ) 1454 ( 661 ) 1795 ( 816 ) 1924 ( 875 ) 1995 ( 907 )

Page 6
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 85 °F 29.4°C

Air Flow Entering Sensible Capacity


Model Total Compressor
Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 131.5 38.5 13.0 86.1 25.2 92.4 27.1 98.8 28.9 105.1 30.8
65 18.3 136.0 39.9 13.2 79.3 23.2 85.6 25.1 92.0 27.0 98.3 28.8
3750 1770
67 19.4 140.4 41.1 13.4 72.3 21.2 78.7 23.1 85.0 24.9 91.4 26.8
69 20.6 144.6 42.4 13.6 65.3 19.1 71.6 21.0 78.0 22.9 84.3 24.7
63 17.2 135.8 39.8 13.2 93.6 27.4 101.1 29.6 108.5 31.8 115.9 34.0
65 18.3 140.5 41.2 13.4 85.8 25.1 93.2 27.3 100.6 29.5 108.0 31.7
4500 2124
67 19.4 145.1 42.5 13.6 77.8 22.8 85.2 25.0 92.6 27.1 100.0 29.3
69 20.6 149.5 43.8 13.8 69.7 20.4 77.1 22.6 84.5 24.8 91.9 26.9
150
63 17.2 138.2 40.5 13.3 98.5 28.9 106.6 31.2 114.6 33.6 122.7 36.0
65 18.3 143.0 41.9 13.5 90.0 26.4 98.1 28.7 106.1 31.1 114.2 33.5
5000 2360
67 19.4 147.7 43.3 13.7 81.2 23.8 89.3 26.2 97.4 28.6 105.5 30.9
69 20.6 152.2 44.6 13.9 72.5 21.3 80.6 23.6 88.7 26.0 96.8 28.4
63 17.2 142.0 41.6 13.5 107.7 31.6 117.1 34.3 126.5 37.1 135.9 39.8
65 18.3 147.0 43.1 13.7 97.9 28.7 107.3 31.4 116.7 34.2 126.1 37.0
6000 2831
67 19.4 151.9 44.5 13.9 87.9 25.8 97.3 28.5 106.7 31.3 116.1 34.0
69 20.6 156.6 45.9 14.1 77.8 22.8 87.2 25.5 96.6 28.3 106.0 31.1
63 17.2 166.9 48.9 15.4 106.1 31.1 114.4 33.5 122.7 36.0 131.0 38.4
65 18.3 172.9 50.7 15.7 97.4 28.6 105.7 31.0 114.0 33.4 122.3 35.8
4000 1888
67 19.4 178.7 52.4 15.9 88.5 25.9 96.8 28.4 105.1 30.8 113.3 33.2
69 20.6 184.2 54.0 16.2 79.5 23.3 87.7 25.7 96.0 28.1 104.3 30.6
63 17.2 173.4 50.8 15.7 119.1 34.9 129.2 37.9 139.4 40.8 149.5 43.8
65 18.3 179.7 52.7 16.0 108.5 31.8 118.6 34.8 128.8 37.7 138.9 40.7
5000 2360
67 19.4 185.7 54.4 16.3 97.7 28.6 107.9 31.6 118.0 34.6 128.2 37.6
69 20.6 191.5 56.1 16.5 86.8 25.4 96.9 28.4 107.1 31.4 117.2 34.4
190
63 17.2 177.4 52.0 15.9 129.0 37.8 140.6 41.2 152.2 44.6 163.8 48.0
65 18.3 183.8 53.9 16.2 117.0 34.3 128.6 37.7 140.2 41.1 151.8 44.5
5800 2737
67 19.4 190.1 55.7 16.5 104.7 30.7 116.3 34.1 127.9 37.5 139.5 40.9
69 20.6 196.1 57.5 16.7 92.4 27.1 104.0 30.5 115.6 33.9 127.2 37.3
63 17.2 180.2 52.8 16.0 137.4 40.3 150.2 44.0 163.0 47.8 175.8 51.5
65 18.3 186.8 54.7 16.3 124.1 36.4 137.0 40.1 149.8 43.9 162.6 47.7
6500 3067
67 19.4 193.2 56.6 16.6 110.7 32.4 123.5 36.2 136.3 40.0 149.2 43.7
69 20.6 199.3 58.4 16.9 97.1 28.5 109.9 32.2 122.7 36.0 135.6 39.7
63 17.2 215.5 63.2 17.3 142.3 41.7 152.3 44.6 162.3 47.6 172.3 50.5
65 18.3 222.8 65.3 17.5 131.4 38.5 141.4 41.5 151.4 44.4 161.4 47.3
5400 2548
67 19.4 229.7 67.3 17.7 120.4 35.3 130.4 38.2 140.4 41.1 150.4 44.1
69 20.6 236.5 69.3 17.9 109.1 32.0 119.1 34.9 129.1 37.8 139.1 40.8
63 17.2 223.1 65.4 17.5 154.0 45.1 165.6 48.5 177.2 51.9 188.8 55.3
65 18.3 230.7 67.6 17.7 141.6 41.5 153.2 44.9 164.8 48.3 176.4 51.7
6400 3020
67 19.4 238.0 69.8 17.9 128.8 37.8 140.5 41.2 152.1 44.6 163.7 48.0
69 20.6 245.2 71.9 18.2 116.0 34.0 127.6 37.4 139.2 40.8 150.8 44.2
240
63 17.2 229.1 67.2 17.7 165.1 48.4 178.3 52.3 191.5 56.1 204.6 60.0
65 18.3 237.0 69.5 17.9 151.1 44.3 164.3 48.2 177.5 52.0 190.6 55.9
7400 3492
67 19.4 244.7 71.7 18.1 137.0 40.1 150.1 44.0 163.3 47.9 176.5 51.7
69 20.6 252.1 73.9 18.4 122.5 35.9 135.7 39.8 148.9 43.6 162.0 47.5
63 17.2 234.0 68.6 17.8 175.8 51.5 190.5 55.8 205.2 60.1 219.9 64.4
65 18.3 242.1 71.0 18.1 160.3 47.0 175.0 51.3 189.7 55.6 204.4 59.9
8400 3964
67 19.4 250.0 73.3 18.3 144.6 42.4 159.2 46.7 173.9 51.0 188.6 55.3
69 20.6 257.6 75.5 18.5 128.7 37.7 143.4 42.0 158.1 46.3 172.8 50.6

Page 7
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 85 °F 29.4°C

Air Flow Entering Sensible Capacity


Model Total Compressor
Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 228.5 67.0 16.9 155.3 45.5 166.6 48.8 178.0 52.2 189.4 55.5
65 18.3 236.4 69.3 17.1 143.1 42.0 154.5 45.3 165.9 48.6 177.3 52.0
6000 2831
67 19.4 244.1 71.5 17.3 130.7 38.3 142.1 41.6 153.4 45.0 164.8 48.3
69 20.6 251.5 73.7 17.5 118.1 34.6 129.5 37.9 140.8 41.3 152.2 44.6
63 17.2 235.7 69.1 17.1 167.4 49.1 180.5 52.9 193.5 56.7 206.6 60.5
65 18.3 244.0 71.5 17.3 153.6 45.0 166.7 48.8 179.7 52.7 192.8 56.5
7000 3303
67 19.4 252.0 73.9 17.5 139.5 40.9 152.6 44.7 165.6 48.5 178.7 52.4
69 20.6 259.8 76.1 17.7 125.2 36.7 138.3 40.5 151.3 44.4 164.4 48.2
260
63 17.2 241.7 70.8 17.2 179.1 52.5 193.8 56.8 208.4 61.1 223.1 65.4
65 18.3 250.3 73.4 17.5 163.6 48.0 178.3 52.3 193.0 56.6 207.7 60.9
8000 3775
67 19.4 258.6 75.8 17.7 148.0 43.4 162.7 47.7 177.3 52.0 192.0 56.3
69 20.6 266.7 78.2 17.9 132.1 38.7 146.7 43.0 161.4 47.3 176.1 51.6
63 17.2 246.7 72.3 17.4 190.3 55.8 206.6 60.5 222.8 65.3 239.1 70.1
65 18.3 255.6 74.9 17.6 173.3 50.8 189.6 55.6 205.9 60.3 222.2 65.1
9000 4247
67 19.4 264.1 77.4 17.8 156.0 45.7 172.3 50.5 188.5 55.3 204.8 60.0
69 20.6 272.5 79.9 18.0 138.6 40.6 154.9 45.4 171.2 50.2 187.4 54.9
63 17.2 289.4 84.8 28.8 196.3 57.5 209.4 61.4 222.4 65.2 235.5 69.0
65 18.3 298.5 87.5 29.2 181.9 53.3 194.9 57.1 208.0 61.0 221.0 64.8
7000 3303
67 19.4 307.4 90.1 29.6 167.1 49.0 180.2 52.8 193.2 56.6 206.3 60.5
69 20.6 315.9 92.6 30.0 152.0 44.6 165.1 48.4 178.1 52.2 191.2 56.0
63 17.2 301.1 88.3 29.3 214.0 62.7 229.5 67.3 245.0 71.8 260.5 76.3
65 18.3 310.8 91.1 29.7 197.2 57.8 212.7 62.3 228.2 66.9 243.6 71.4
8500 4011
67 19.4 320.2 93.8 30.2 179.9 52.7 195.4 57.3 210.9 61.8 226.4 66.3
69 20.6 329.2 96.5 30.6 162.5 47.6 178.0 52.2 193.5 56.7 209.0 61.2
340
63 17.2 310.3 90.9 29.7 230.8 67.7 248.7 72.9 266.5 78.1 284.3 83.3
65 18.3 320.4 93.9 30.2 211.6 62.0 229.4 67.2 247.3 72.5 265.1 77.7
10000 4719
67 19.4 330.1 96.8 30.6 192.1 56.3 209.9 61.5 227.7 66.8 245.6 72.0
69 20.6 339.5 99.5 31.1 172.1 50.5 190.0 55.7 207.8 60.9 225.6 66.1
63 17.2 317.4 93.0 30.0 246.8 72.3 266.9 78.2 287.1 84.1 307.2 90.0
65 18.3 327.9 96.1 30.5 225.3 66.0 245.4 71.9 265.5 77.8 285.6 83.7
11500 5427
67 19.4 337.9 99.0 31.0 203.4 59.6 223.5 65.5 243.7 71.4 263.8 77.3
69 20.6 347.6 101.9 31.5 181.4 53.2 201.5 59.1 221.6 65.0 241.8 70.9

Note :These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Page 8
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 95 °F 35.0 °C

Air Flow Entering


Model Total Compressor Sensible Capacity
Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 125.2 36.7 13.8 83.7 24.5 90.0 26.4 96.4 28.2 102.7 30.1
65 18.3 129.6 38.0 14.1 76.9 22.5 83.3 24.4 89.6 26.3 96.0 28.1
3750 1770
67 19.4 133.8 39.2 14.3 70.0 20.5 76.4 22.4 82.7 24.2 89.1 26.1
69 20.6 137.8 40.4 14.5 63.0 18.5 69.3 20.3 75.7 22.2 82.0 24.0
63 17.2 129.2 37.9 14.0 91.2 26.7 98.6 28.9 106.0 31.1 113.4 33.2
65 18.3 133.8 39.2 14.3 83.4 24.4 90.8 26.6 98.2 28.8 105.6 31.0
4500 2124
67 19.4 138.1 40.5 14.5 75.4 22.1 82.8 24.3 90.2 26.4 97.6 28.6
69 20.6 142.4 41.7 14.8 67.4 19.8 74.8 21.9 82.2 24.1 89.6 26.3
150
63 17.2 131.4 38.5 14.2 96.0 28.1 104.1 30.5 112.2 32.9 120.3 35.2
65 18.3 136.1 39.9 14.4 87.6 25.7 95.6 28.0 103.7 30.4 111.8 32.8
5000 2360
67 19.4 140.5 41.2 14.7 78.9 23.1 87.0 25.5 95.1 27.9 103.1 30.2
69 20.6 144.9 42.5 14.9 70.2 20.6 78.3 22.9 86.3 25.3 94.4 27.7
63 17.2 134.9 39.5 14.4 105.2 30.8 114.6 33.6 124.1 36.4 133.5 39.1
65 18.3 139.7 41.0 14.6 95.4 28.0 104.8 30.7 114.2 33.5 123.7 36.2
6000 2831
67 19.4 144.4 42.3 14.9 85.5 25.1 94.9 27.8 104.3 30.6 113.7 33.3
69 20.6 148.9 43.7 15.1 75.4 22.1 84.8 24.9 94.2 27.6 103.6 30.4
63 17.2 159.1 46.6 16.4 103.4 30.3 111.7 32.7 119.9 35.2 128.2 37.6
65 18.3 164.8 48.3 16.7 94.7 27.8 103.0 30.2 111.3 32.6 119.6 35.0
4000 1888
67 19.4 170.4 49.9 17.0 85.8 25.1 94.1 27.6 102.4 30.0 110.7 32.4
69 20.6 175.7 51.5 17.3 76.8 22.5 85.1 24.9 93.4 27.4 101.6 29.8
63 17.2 165.0 48.4 16.7 116.2 34.1 126.4 37.0 136.5 40.0 146.7 43.0
65 18.3 171.1 50.1 17.0 105.7 31.0 115.8 33.9 126.0 36.9 136.1 39.9
5000 2360
67 19.4 176.9 51.8 17.3 94.9 27.8 105.1 30.8 115.2 33.8 125.4 36.8
69 20.6 182.5 53.5 17.6 84.1 24.7 94.3 27.6 104.4 30.6 114.6 33.6
190
63 17.2 168.7 49.4 16.9 126.1 37.0 137.7 40.4 149.3 43.8 160.9 47.2
65 18.3 174.9 51.3 17.2 114.2 33.5 125.8 36.9 137.4 40.3 149.0 43.7
5800 2737
67 19.4 180.9 53.0 17.6 102.0 29.9 113.6 33.3 125.1 36.7 136.7 40.1
69 20.6 186.7 54.7 17.8 89.7 26.3 101.3 29.7 112.9 33.1 124.5 36.5
63 17.2 171.3 50.2 17.1 134.5 39.4 147.3 43.2 160.1 46.9 171.3 50.2
65 18.3 177.7 52.1 17.4 121.3 35.5 134.1 39.3 146.9 43.1 159.8 46.8
6500 3067
67 19.4 183.8 53.9 17.7 107.9 31.6 120.7 35.4 133.6 39.1 146.4 42.9
69 20.6 189.7 55.6 18.0 94.3 27.6 107.2 31.4 120.0 35.2 132.8 38.9
63 17.2 206.7 60.6 19.1 138.6 40.6 148.6 43.6 158.6 46.5 168.6 49.4
65 18.3 213.7 62.6 19.3 127.9 37.5 137.9 40.4 147.9 43.3 157.9 46.3
5400 2548
67 19.4 220.4 64.6 19.5 116.9 34.3 126.9 37.2 136.9 40.1 146.9 43.0
69 20.6 227.0 66.5 19.7 105.7 31.0 115.7 33.9 125.7 36.9 135.7 39.8
63 17.2 213.7 62.6 19.3 150.3 44.0 161.9 47.5 173.5 50.9 185.1 54.3
65 18.3 221.1 64.8 19.5 137.9 40.4 149.5 43.8 161.2 47.2 172.8 50.6
6400 3020
67 19.4 228.3 66.9 19.8 125.4 36.7 137.0 40.1 148.6 43.5 160.2 47.0
69 20.6 235.2 68.9 20.0 112.6 33.0 124.2 36.4 135.8 39.8 147.4 43.2
240
63 17.2 219.4 64.3 19.5 161.4 47.3 174.6 51.2 187.7 55.0 200.9 58.9
65 18.3 227.1 66.6 19.7 147.5 43.2 160.6 47.1 173.8 50.9 187.0 54.8
7400 3492
67 19.4 234.5 68.7 20.0 133.3 39.1 146.5 42.9 159.7 46.8 172.9 50.7
69 20.6 241.7 70.9 20.2 119.0 34.9 132.2 38.8 145.4 42.6 158.6 46.5
63 17.2 223.9 65.6 19.6 172.0 50.4 186.7 54.7 201.4 59.0 216.1 63.3
65 18.3 231.9 68.0 19.9 156.7 45.9 171.4 50.2 186.1 54.5 200.7 58.8
8400 3964
67 19.4 239.6 70.2 20.1 140.9 41.3 155.6 45.6 170.3 49.9 185.0 54.2
69 20.6 247.0 72.4 20.4 125.2 36.7 139.9 41.0 154.6 45.3 169.3 49.6

Page 9
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 95 °F 35.0 °C

Air Flow Entering


Model Total Compressor Sensible Capacity
Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 219.1 64.2 18.6 151.4 44.4 162.8 47.7 174.2 51.1 185.6 54.4
65 18.3 226.7 66.4 18.8 139.4 40.9 150.7 44.2 162.1 47.5 173.5 50.9
6000 2831
67 19.4 234.2 68.6 19.0 127.0 37.2 138.4 40.6 149.8 43.9 161.1 47.2
69 20.6 241.4 70.7 19.2 114.5 33.6 125.9 36.9 137.3 40.2 148.6 43.6
63 17.2 225.8 66.2 18.8 163.5 47.9 176.6 51.8 189.6 55.6 202.7 59.4
65 18.3 233.8 68.5 19.0 149.8 43.9 162.8 47.7 175.9 51.6 188.9 55.4
7000 3303
67 19.4 241.7 70.8 19.2 135.8 39.8 148.9 43.6 161.9 47.5 175.0 51.3
69 20.6 249.2 73.0 19.4 121.6 35.6 134.6 39.5 147.7 43.3 160.7 47.1
260
63 17.2 231.4 67.8 19.0 175.1 51.3 189.8 55.6 204.5 59.9 219.2 64.2
65 18.3 239.8 70.3 19.2 159.8 46.8 174.4 51.1 189.1 55.4 203.8 59.7
8000 3775
67 19.4 247.8 72.6 19.4 144.1 42.2 158.8 46.5 173.5 50.9 188.2 55.2
69 20.6 255.8 75.0 19.6 128.4 37.6 143.1 41.9 157.8 46.2 172.5 50.5
63 17.2 236.0 69.2 19.1 186.3 54.6 202.6 59.4 218.9 64.1 235.1 68.9
65 18.3 244.7 71.7 19.3 169.5 49.7 185.7 54.4 202.0 59.2 218.3 64.0
9000 4247
67 19.4 253.0 74.2 19.5 152.2 44.6 168.4 49.4 184.7 54.1 201.0 58.9
69 20.6 261.3 76.6 19.7 134.9 39.5 151.2 44.3 167.4 49.1 183.7 53.8
63 17.2 277.2 81.3 31.6 190.9 56.0 204.0 59.8 217.0 63.6 230.1 67.4
65 18.3 286.1 83.9 32.0 176.6 51.8 189.7 55.6 202.7 59.4 215.8 63.2
7000 3303
67 19.4 294.8 86.4 32.4 162.0 47.5 175.0 51.3 188.1 55.1 201.1 58.9
69 20.6 303.1 88.8 32.8 147.0 43.1 160.1 46.9 173.1 50.7 186.2 54.6
63 17.2 288.3 84.5 32.1 208.6 61.1 224.1 65.7 239.5 70.2 255.0 74.7
65 18.3 297.7 87.3 32.5 191.9 56.2 207.3 60.8 222.8 65.3 238.3 69.9
8500 4011
67 19.4 306.8 89.9 32.9 174.7 51.2 190.2 55.8 205.7 60.3 221.2 64.8
69 20.6 315.6 92.5 33.4 157.4 46.1 172.9 50.7 188.4 55.2 203.8 59.7
340
63 17.2 296.9 87.0 32.5 225.3 66.0 243.1 71.3 261.0 76.5 278.8 81.7
65 18.3 306.7 89.9 32.9 206.2 60.4 224.0 65.7 241.8 70.9 259.7 76.1
10000 4719
67 19.4 316.2 92.7 33.4 186.8 54.8 204.7 60.0 222.5 65.2 240.3 70.4
69 20.6 325.3 95.4 33.8 167.1 49.0 184.9 54.2 202.7 59.4 220.6 64.7
63 17.2 303.6 89.0 32.8 241.2 70.7 261.4 76.6 281.5 82.5 301.6 88.4
65 18.3 313.7 92.0 33.3 219.9 64.4 240.0 70.3 260.1 76.2 280.2 82.1
11500 5427
67 19.4 323.5 94.8 33.7 198.1 58.1 218.3 64.0 238.4 69.9 258.5 75.8
69 20.6 332.9 97.6 34.2 176.2 51.7 196.4 57.6 216.5 63.5 236.6 69.3

Note :These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Page 10
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 105 °F 40.6 °C

Air Flow Entering


Model Total Compressor Sensible Capacity
Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 118.5 34.7 14.7 81.2 23.8 87.5 25.6 93.8 27.5 100.2 29.4
65 18.3 122.7 36.0 15.0 74.5 21.8 80.8 23.7 87.1 25.5 93.5 27.4
3750 1770
67 19.4 126.8 37.2 15.2 67.6 19.8 74.0 21.7 80.3 23.5 86.7 25.4
69 20.6 130.8 38.3 15.4 60.7 17.8 67.0 19.7 73.4 21.5 79.7 23.4
63 17.2 122.2 35.8 14.9 88.7 26.0 96.1 28.2 103.5 30.3 110.9 32.5
65 18.3 126.6 37.1 15.2 80.9 23.7 88.3 25.9 95.8 28.1 103.2 30.2
4500 2124
67 19.4 130.9 38.4 15.5 73.0 21.4 80.4 23.6 87.8 25.7 95.2 27.9
69 20.6 135.0 39.6 15.7 65.0 19.1 72.4 21.2 79.8 23.4 87.3 25.6
150
63 17.2 124.3 36.4 15.0 93.4 27.4 101.5 29.8 109.6 32.1 117.7 34.5
65 18.3 128.8 37.7 15.3 85.0 24.9 93.1 27.3 101.2 29.7 109.3 32.0
5000 2360
67 19.4 133.1 39.0 15.6 76.5 22.4 84.5 24.8 92.6 27.2 100.7 29.5
69 20.6 137.3 40.2 15.8 67.8 19.9 75.9 22.2 83.9 24.6 92.0 27.0
63 17.2 127.5 37.4 15.2 102.7 30.1 112.1 32.9 121.5 35.6 127.5 37.4
65 18.3 132.2 38.7 15.5 92.9 27.2 102.3 30.0 111.7 32.7 121.1 35.5
6000 2831
67 19.4 136.6 40.1 15.8 83.0 24.3 92.4 27.1 101.8 29.8 111.3 32.6
69 20.6 140.9 41.3 16.1 72.9 21.4 82.4 24.1 91.8 26.9 101.2 29.7
63 17.2 150.9 44.2 17.5 100.5 29.5 108.8 31.9 117.1 34.3 125.4 36.7
65 18.3 156.4 45.9 17.8 91.9 26.9 100.2 29.4 108.5 31.8 116.7 34.2
4000 1888
67 19.4 161.8 47.4 18.1 83.1 24.3 91.4 26.8 99.7 29.2 107.9 31.6
69 20.6 166.9 48.9 18.4 74.1 21.7 82.4 24.2 90.7 26.6 99.0 29.0
63 17.2 156.4 45.8 17.8 113.3 33.2 123.5 36.2 133.7 39.2 143.8 42.1
65 18.3 162.2 47.5 18.2 102.9 30.1 113.0 33.1 123.2 36.1 133.3 39.1
5000 2360
67 19.4 167.8 49.2 18.5 92.2 27.0 102.3 30.0 112.5 33.0 122.6 35.9
69 20.6 173.1 50.7 18.8 81.4 23.9 91.5 26.8 101.7 29.8 111.8 32.8
190
63 17.2 159.8 46.8 18.0 123.2 36.1 134.8 39.5 146.4 42.9 158.0 46.3
65 18.3 165.8 48.6 18.4 111.3 32.6 122.9 36.0 134.5 39.4 146.1 42.8
5800 2737
67 19.4 171.5 50.3 18.7 99.2 29.1 110.8 32.5 122.4 35.9 134.0 39.3
69 20.6 177.0 51.9 19.0 86.9 25.5 98.5 28.9 110.1 32.3 121.7 35.7
63 17.2 162.2 47.5 18.2 131.6 38.6 144.4 42.3 157.2 46.1 162.2 47.5
65 18.3 168.3 49.3 18.5 118.4 34.7 131.2 38.5 144.0 42.2 156.9 46.0
6500 3067
67 19.4 174.1 51.0 18.9 105.1 30.8 117.9 34.6 130.7 38.3 143.6 42.1
69 20.6 179.7 52.7 19.2 91.5 26.8 104.4 30.6 117.2 34.3 130.0 38.1
63 17.2 197.6 57.9 21.2 135.0 39.6 145.0 42.5 155.0 45.4 165.0 48.4
65 18.3 204.4 59.9 21.4 124.3 36.4 134.3 39.4 144.3 42.3 154.3 45.2
5400 2548
67 19.4 211.0 61.8 21.6 113.3 33.2 123.4 36.2 133.4 39.1 143.4 42.0
69 20.6 217.3 63.7 21.7 102.3 30.0 112.3 32.9 122.3 35.8 132.3 38.8
63 17.2 204.2 59.9 21.4 146.6 43.0 158.2 46.4 169.8 49.8 181.4 53.2
65 18.3 211.4 61.9 21.6 134.3 39.4 145.9 42.8 157.5 46.2 169.1 49.6
6400 3020
67 19.4 218.3 64.0 21.8 121.8 35.7 133.4 39.1 145.0 42.5 156.6 45.9
69 20.6 224.9 65.9 22.0 109.0 32.0 120.7 35.4 132.3 38.8 143.9 42.2
240
63 17.2 209.5 61.4 21.5 157.6 46.2 170.8 50.1 183.9 53.9 197.1 57.8
65 18.3 216.9 63.6 21.7 143.8 42.1 156.9 46.0 170.1 49.9 183.3 53.7
7400 3492
67 19.4 224.1 65.7 21.9 129.7 38.0 142.9 41.9 156.0 45.7 169.2 49.6
69 20.6 230.9 67.7 22.1 115.5 33.8 128.7 37.7 141.8 41.6 155.0 45.4
63 17.2 213.7 62.6 21.6 168.2 49.3 182.9 53.6 197.6 57.9 212.2 62.2
65 18.3 221.4 64.9 21.9 152.9 44.8 167.6 49.1 182.3 53.4 197.0 57.7
8400 3964
67 19.4 228.7 67.0 22.1 137.2 40.2 151.9 44.5 166.6 48.8 181.3 53.1
69 20.6 235.8 69.1 22.3 121.5 35.6 136.2 39.9 150.9 44.2 165.6 48.5

Page 11
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 105 °F 40.6 °C

Air Flow Entering


Total Compressor Sensible Capacity
Model Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 209.3 61.4 20.6 147.6 43.3 158.9 46.6 170.3 49.9 181.7 53.3
65 18.3 216.8 63.5 20.8 135.6 39.7 146.9 43.1 158.3 46.4 169.7 49.7
6000 2831
67 19.4 224.0 65.7 21.0 123.3 36.1 134.7 39.5 146.0 42.8 157.4 46.1
69 20.6 231.0 67.7 21.2 110.8 32.5 122.2 35.8 133.6 39.2 144.9 42.5
63 17.2 215.6 63.2 20.8 159.6 46.8 172.7 50.6 185.7 54.4 198.8 58.3
65 18.3 223.4 65.5 21.0 145.9 42.8 159.0 46.6 172.0 50.4 185.1 54.2
7000 3303
67 19.4 231.0 67.7 21.2 132.0 38.7 145.1 42.5 158.1 46.4 171.2 50.2
69 20.6 238.3 69.8 21.4 117.9 34.6 131.0 38.4 144.0 42.2 157.1 46.0
260
63 17.2 220.8 64.7 20.9 171.2 50.2 185.8 54.5 200.5 58.8 215.2 63.1
65 18.3 228.9 67.1 21.1 155.9 45.7 170.6 50.0 185.2 54.3 199.9 58.6
8000 3775
67 19.4 236.7 69.4 21.3 140.3 41.1 155.0 45.4 169.7 49.7 184.3 54.0
69 20.6 244.4 71.6 21.5 124.7 36.5 139.4 40.8 154.0 45.1 168.7 49.5
63 17.2 225.2 66.0 21.0 182.3 53.4 198.5 58.2 214.8 63.0 225.2 66.0
65 18.3 233.5 68.4 21.3 165.5 48.5 181.7 53.3 198.0 58.0 214.3 62.8
9000 4247
67 19.4 241.6 70.8 21.5 148.3 43.5 164.6 48.2 180.8 53.0 197.1 57.8
69 20.6 249.6 73.1 21.7 131.1 38.4 147.4 43.2 163.6 48.0 179.9 52.7
63 17.2 264.9 77.6 34.6 185.5 54.4 198.6 58.2 211.6 62.0 224.7 65.8
65 18.3 273.4 80.1 35.1 171.3 50.2 184.3 54.0 197.4 57.8 210.4 61.7
7000 3303
67 19.4 281.7 82.6 35.5 156.7 45.9 169.7 49.8 182.8 53.6 195.8 57.4
69 20.6 289.7 84.9 35.9 141.9 41.6 154.9 45.4 168.0 49.2 181.0 53.1
63 17.2 275.1 80.6 35.2 203.0 59.5 218.5 64.0 234.0 68.6 249.5 73.1
65 18.3 284.1 83.3 35.6 186.4 54.6 201.8 59.2 217.3 63.7 232.8 68.2
8500 4011
67 19.4 292.9 85.9 36.1 169.4 49.6 184.8 54.2 200.3 58.7 215.8 63.3
69 20.6 301.4 88.3 36.5 152.1 44.6 167.6 49.1 183.1 53.7 198.6 58.2
340
63 17.2 283.0 82.9 35.6 219.7 64.4 237.5 69.6 255.3 74.8 273.2 80.1
65 18.3 292.5 85.7 36.1 200.6 58.8 218.5 64.0 236.3 69.3 254.1 74.5
10000 4719
67 19.4 301.6 88.4 36.5 181.3 53.2 199.2 58.4 217.0 63.6 234.8 68.8
69 20.6 310.5 91.0 36.9 161.8 47.4 179.7 52.7 197.5 57.9 215.3 63.1
63 17.2 289.2 84.8 35.9 235.5 69.0 255.6 74.9 275.7 80.8 289.2 84.8
65 18.3 299.0 87.6 36.4 214.3 62.8 234.4 68.7 254.6 74.6 274.7 80.5
11500 5427
67 19.4 308.5 90.4 36.8 192.6 56.5 212.8 62.4 232.9 68.3 253.0 74.2
69 20.6 317.6 93.1 37.3 170.9 50.1 191.0 56.0 211.2 61.9 231.3 67.8

Note :These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Page 12
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 115 °F 46.1 °C

Entering
Model Air Flow Rate Total Compressor Sensible Capacity
Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 111.5 32.7 15.5 78.5 23.0 84.9 24.9 91.2 26.7 97.6 28.6
65 18.3 115.6 33.9 15.8 71.9 21.1 78.2 22.9 84.6 24.8 90.9 26.7
3750 1770
67 19.4 119.5 35.0 16.1 65.1 19.1 71.5 20.9 77.8 22.8 84.2 24.7
69 20.6 123.3 36.1 16.3 58.3 17.1 64.6 18.9 71.0 20.8 77.3 22.7
63 17.2 114.9 33.7 15.7 86.0 25.2 93.4 27.4 100.8 29.6 108.2 31.7
65 18.3 119.2 34.9 16.0 78.4 23.0 85.8 25.1 93.2 27.3 100.6 29.5
4500 2124
67 19.4 123.2 36.1 16.3 70.5 20.7 77.9 22.8 85.3 25.0 92.7 27.2
69 20.6 127.1 37.3 16.6 62.6 18.3 70.0 20.5 77.4 22.7 84.8 24.8
150
63 17.2 116.8 34.2 15.9 90.8 26.6 98.9 29.0 107.0 31.3 115.0 33.7
65 18.3 121.1 35.5 16.2 82.4 24.2 90.5 26.5 98.6 28.9 106.7 31.3
5000 2360
67 19.4 125.3 36.7 16.5 73.9 21.7 82.0 24.0 90.1 26.4 98.2 28.8
69 20.6 129.2 37.9 16.8 65.2 19.1 73.3 21.5 81.4 23.9 89.5 26.2
63 17.2 119.7 35.1 16.1 100.0 29.3 109.4 32.1 118.8 34.8 119.7 35.1
65 18.3 124.2 36.4 16.4 90.2 26.4 99.6 29.2 109.1 32.0 118.5 34.7
6000 2831
67 19.4 128.4 37.6 16.7 80.4 23.6 89.8 26.3 99.2 29.1 108.6 31.8
69 20.6 132.4 38.8 17.0 70.4 20.6 79.8 23.4 89.2 26.1 98.6 28.9
63 17.2 142.3 41.7 18.5 97.6 28.6 105.9 31.0 114.1 33.5 122.4 35.9
65 18.3 147.7 43.3 18.9 89.0 26.1 97.3 28.5 105.6 30.9 113.8 33.4
4000 1888
67 19.4 152.8 44.8 19.2 80.3 23.5 88.5 26.0 96.8 28.4 105.1 30.8
69 20.6 157.6 46.2 19.6 71.3 20.9 79.6 23.3 87.9 25.8 96.2 28.2
63 17.2 147.4 43.2 18.9 110.4 32.3 120.5 35.3 130.7 38.3 140.8 41.3
65 18.3 153.0 44.8 19.2 100.0 29.3 110.1 32.3 120.3 35.2 130.4 38.2
5000 2360
67 19.4 158.2 46.4 19.6 89.2 26.2 99.4 29.1 109.5 32.1 119.7 35.1
69 20.6 163.0 47.8 20.0 78.5 23.0 88.6 26.0 98.8 28.9 108.9 31.9
190
63 17.2 150.5 44.1 19.1 120.2 35.2 131.8 38.6 143.4 42.0 150.5 44.1
65 18.3 156.1 45.8 19.5 108.3 31.7 119.9 35.1 131.5 38.5 143.1 41.9
5800 2737
67 19.4 161.4 47.3 19.8 96.2 28.2 107.8 31.6 119.4 35.0 131.0 38.4
69 20.6 166.3 48.7 20.2 83.9 24.6 95.5 28.0 107.0 31.4 118.6 34.8
63 17.2 152.6 44.7 19.2 128.6 37.7 141.4 41.4 152.6 44.7 152.6 44.7
65 18.3 158.3 46.4 19.6 115.3 33.8 128.2 37.6 141.0 41.3 153.8 45.1
6500 3067
67 19.4 163.6 47.9 20.0 102.0 29.9 114.8 33.7 127.7 37.4 140.5 41.2
69 20.6 168.6 49.4 20.4 88.4 25.9 101.3 29.7 114.1 33.4 126.9 37.2
63 17.2 188.2 55.2 23.4 131.3 38.5 141.3 41.4 151.3 44.3 161.3 47.3
65 18.3 194.9 57.1 23.6 120.7 35.4 130.7 38.3 140.7 41.2 150.7 44.2
5400 2548
67 19.4 201.3 59.0 23.8 109.8 32.2 119.8 35.1 129.8 38.0 139.8 41.0
69 20.6 207.4 60.8 24.0 98.8 29.0 108.8 31.9 118.8 34.8 128.8 37.8
63 17.2 194.4 57.0 23.5 142.8 41.9 154.4 45.3 166.0 48.7 177.6 52.1
65 18.3 201.4 59.0 23.8 130.6 38.3 142.2 41.7 153.8 45.1 165.4 48.5
6400 3020
67 19.4 208.1 61.0 24.0 118.2 34.6 129.8 38.0 141.4 41.4 153.0 44.9
69 20.6 214.5 62.9 24.2 105.6 30.9 117.2 34.3 128.8 37.7 140.4 41.2
240
63 17.2 199.3 58.4 23.7 153.8 45.1 167.0 48.9 180.1 52.8 193.3 56.7
65 18.3 206.6 60.5 23.9 140.1 41.1 153.3 44.9 166.4 48.8 179.6 52.6
7400 3492
67 19.4 213.5 62.6 24.2 126.0 36.9 139.2 40.8 152.4 44.7 165.5 48.5
69 20.6 220.1 64.5 24.4 111.9 32.8 125.1 36.7 138.3 40.5 151.4 44.4
63 17.2 203.3 59.6 23.8 164.3 48.2 179.0 52.5 193.7 56.8 203.3 59.6
65 18.3 210.7 61.7 24.1 149.1 43.7 163.8 48.0 178.5 52.3 193.2 56.6
8400 3964
67 19.4 217.7 63.8 24.3 133.6 39.2 148.3 43.5 163.0 47.8 177.7 52.1
69 20.6 224.6 65.8 24.5 117.9 34.6 132.6 38.9 147.3 43.2 162.0 47.5
Page 13
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 115 °F 46.1 °C

Entering
Model Air Flow Rate Total Compressor Sensible Capacity
Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 199.4 58.4 22.7 143.7 42.1 155.0 45.4 166.4 48.8 177.8 52.1
65 18.3 206.6 60.6 22.9 131.7 38.6 143.1 41.9 154.5 45.3 165.9 48.6
6000 2831
67 19.4 213.6 62.6 23.1 119.6 35.0 130.9 38.4 142.3 41.7 153.7 45.0
69 20.6 220.3 64.6 23.3 107.2 31.4 118.5 34.7 129.9 38.1 141.3 41.4
63 17.2 205.2 60.2 22.9 155.6 45.6 168.7 49.4 181.7 53.3 194.8 57.1
65 18.3 212.8 62.4 23.1 142.0 41.6 155.1 45.5 168.1 49.3 181.2 53.1
7000 3303
67 19.4 220.0 64.5 23.3 128.2 37.6 141.2 41.4 154.3 45.2 167.3 49.0
69 20.6 227.1 66.6 23.4 114.2 33.5 127.2 37.3 140.3 41.1 153.3 44.9
260
63 17.2 210.1 61.6 23.0 167.1 49.0 181.8 53.3 196.5 57.6 210.1 61.6
65 18.3 217.8 63.8 23.2 151.9 44.5 166.6 48.8 181.3 53.1 196.0 57.4
8000 3775
67 19.4 225.4 66.1 23.4 136.4 40.0 151.1 44.3 165.7 48.6 180.4 52.9
69 20.6 232.7 68.2 23.6 120.8 35.4 135.5 39.7 150.2 44.0 164.9 48.3
63 17.2 214.1 62.7 23.1 178.2 52.2 194.5 57.0 210.7 61.8 214.1 62.7
65 18.3 222.0 65.1 23.3 161.4 47.3 177.7 52.1 194.0 56.8 210.2 61.6
9000 4247
67 19.4 229.8 67.4 23.5 144.4 42.3 160.6 47.1 176.9 51.9 193.2 56.6
69 20.6 237.6 69.6 23.7 127.2 37.3 143.5 42.1 159.7 46.8 176.0 51.6
63 17.2 251.7 73.8 38.3 179.8 52.7 192.9 56.5 205.9 60.4 219.0 64.2
65 18.3 259.9 76.2 38.7 165.7 48.6 178.7 52.4 191.8 56.2 204.8 60.0
7000 3303
67 19.4 267.9 78.5 39.2 151.2 44.3 164.2 48.1 177.3 52.0 190.3 55.8
69 20.6 275.7 80.8 39.6 136.6 40.0 149.6 43.9 162.7 47.7 175.8 51.5
63 17.2 261.1 76.5 38.8 197.2 57.8 212.7 62.3 228.2 66.9 243.7 71.4
65 18.3 269.8 79.1 39.3 180.7 53.0 196.1 57.5 211.6 62.0 227.1 66.6
8500 4011
67 19.4 278.4 81.6 39.7 163.9 48.0 179.4 52.6 194.9 57.1 210.3 61.7
69 20.6 286.7 84.0 40.1 146.8 43.0 162.3 47.6 177.8 52.1 193.2 56.6
340
63 17.2 268.4 78.7 39.2 213.7 62.6 231.6 67.9 249.4 73.1 267.2 78.3
65 18.3 277.6 81.4 39.7 194.9 57.1 212.7 62.3 230.5 67.6 248.4 72.8
10000 4719
67 19.4 286.6 84.0 40.1 175.8 51.5 193.6 56.7 211.4 62.0 229.3 67.2
69 20.6 295.4 86.6 40.4 156.5 45.9 174.3 51.1 192.2 56.3 210.0 61.6
63 17.2 274.1 80.4 39.5 229.5 67.3 249.6 73.2 269.8 79.1 274.1 80.4
65 18.3 283.8 83.2 40.0 208.6 61.1 228.7 67.0 248.8 72.9 268.9 78.8
11500 5427
67 19.4 293.1 85.9 40.3 187.1 54.8 207.2 60.7 227.3 66.6 247.5 72.5
69 20.6 302.3 88.6 40.6 165.6 48.5 185.7 54.4 205.9 60.3 226.0 66.2

Note :These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Page 14
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-407c

AMBIENT 125 °F 51.7 °C

Air Flow Entering


Model Total Compressor Sensible Capacity
Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 103.9 30.4 16.4 75.8 22.2 82.1 24.1 88.5 25.9 94.8 27.8
65 18.3 107.8 31.6 16.7 69.2 20.3 75.6 22.1 81.9 24.0 88.3 25.9
3750 1770
67 19.4 111.7 32.7 17.0 62.5 18.3 68.8 20.2 75.2 22.0 81.5 23.9
69 20.6 115.4 33.8 17.3 55.7 16.3 62.1 18.2 68.4 20.1 74.8 21.9
63 17.2 107.0 31.4 16.6 83.2 24.4 90.6 26.6 98.0 28.7 105.4 30.9
65 18.3 111.1 32.6 17.0 75.6 22.2 83.0 24.3 90.4 26.5 97.8 28.7
4500 2124
67 19.4 115.1 33.7 17.3 67.9 19.9 75.3 22.1 82.7 24.2 90.1 26.4
69 20.6 118.9 34.9 17.6 60.0 17.6 67.4 19.7 74.8 21.9 82.2 24.1
150
63 17.2 108.7 31.9 16.8 88.0 25.8 96.1 28.2 104.2 30.5 108.7 31.9
65 18.3 112.9 33.1 17.1 79.7 23.4 87.8 25.7 95.8 28.1 103.9 30.5
5000 2360
67 19.4 117.0 34.3 17.4 71.3 20.9 79.4 23.3 87.4 25.6 95.5 28.0
69 20.6 120.9 35.4 17.7 62.7 18.4 70.8 20.7 78.9 23.1 87.0 25.5
63 17.2 111.4 32.7 17.0 97.1 28.5 106.5 31.2 111.4 32.7 111.4 32.7
65 18.3 115.8 33.9 17.3 87.5 25.6 96.9 28.4 106.3 31.2 115.7 33.9
6000 2831
67 19.4 119.9 35.2 17.6 77.7 22.8 87.1 25.5 96.5 28.3 106.0 31.1
69 20.6 124.0 36.3 18.0 67.9 19.9 77.3 22.6 86.7 25.4 96.1 28.2
63 17.2 133.1 39.0 19.7 94.4 27.7 102.7 30.1 111.0 32.5 119.3 35.0
65 18.3 138.3 40.5 20.1 85.9 25.2 94.2 27.6 102.5 30.0 110.8 32.5
4000 1888
67 19.4 143.3 42.0 20.4 77.3 22.6 85.5 25.1 93.8 27.5 102.1 29.9
69 20.6 148.0 43.4 20.8 68.5 20.1 76.8 22.5 85.0 24.9 93.3 27.4
63 17.2 137.7 40.4 20.0 107.2 31.4 117.4 34.4 127.5 37.4 137.7 40.3
65 18.3 143.1 42.0 20.4 96.9 28.4 107.0 31.4 117.2 34.3 127.3 37.3
5000 2360
67 19.4 148.3 43.5 20.8 86.3 25.3 96.5 28.3 106.6 31.2 116.8 34.2
69 20.6 153.2 44.9 21.2 75.6 22.2 85.8 25.1 95.9 28.1 106.1 31.1
190
63 17.2 140.6 41.2 20.2 117.1 34.3 128.7 37.7 140.3 41.1 140.6 41.2
65 18.3 146.1 42.8 20.7 105.2 30.8 116.8 34.2 128.4 37.6 140.0 41.0
5800 2737
67 19.4 151.3 44.4 21.1 93.3 27.3 104.8 30.7 116.4 34.1 128.0 37.5
69 20.6 156.4 45.9 21.5 81.1 23.8 92.7 27.2 104.3 30.6 115.9 34.0
63 17.2 142.6 41.8 20.4 125.4 36.8 138.2 40.5 142.6 41.8 142.6 41.8
65 18.3 148.1 43.4 20.8 112.3 32.9 125.1 36.7 137.9 40.4 148.1 43.4
6500 3067
67 19.4 153.5 45.0 21.2 99.1 29.0 111.9 32.8 124.7 36.6 137.6 40.3
69 20.6 158.7 46.5 21.6 85.7 25.1 98.5 28.9 111.4 32.6 124.2 36.4
63 17.2 178.7 52.4 25.8 127.5 37.4 137.5 40.3 147.5 43.2 157.5 46.2
65 18.3 185.2 54.3 26.0 117.0 34.3 127.0 37.2 137.0 40.2 147.0 43.1
5400 2548
67 19.4 191.4 56.1 26.2 106.3 31.1 116.3 34.1 126.3 37.0 136.3 39.9
69 20.6 197.4 57.8 26.4 95.3 27.9 105.3 30.9 115.3 33.8 125.3 36.7
63 17.2 184.5 54.1 26.0 139.0 40.7 150.6 44.1 162.2 47.6 173.8 51.0
65 18.3 191.3 56.1 26.2 126.9 37.2 138.5 40.6 150.1 44.0 161.7 47.4
6400 3020
67 19.4 197.7 58.0 26.5 114.5 33.6 126.1 37.0 137.7 40.4 149.3 43.8
69 20.6 203.9 59.8 26.7 102.0 29.9 113.7 33.3 125.3 36.7 136.9 40.1
240
63 17.2 189.1 55.4 26.2 149.9 43.9 163.1 47.8 176.3 51.7 189.1 55.4
65 18.3 196.0 57.5 26.4 136.3 40.0 149.5 43.8 162.7 47.7 175.9 51.5
7400 3492
67 19.4 202.7 59.4 26.6 122.3 35.9 135.5 39.7 148.7 43.6 161.9 47.4
69 20.6 209.2 61.3 26.9 108.3 31.8 121.5 35.6 134.7 39.5 147.8 43.3
63 17.2 192.7 56.5 26.3 160.5 47.0 175.2 51.3 189.9 55.6 192.7 56.5
65 18.3 199.8 58.6 26.5 145.3 42.6 160.0 46.9 174.7 51.2 189.3 55.5
8400 3964
67 19.4 206.6 60.6 26.8 129.9 38.1 144.6 42.4 159.3 46.7 174.0 51.0
69 20.6 213.3 62.5 27.0 114.3 33.5 129.0 37.8 143.7 42.1 158.3 46.4

Page 15
Packaged Air Conditioners

COOLING PERFORMANCE DATA - 60 Hz R-22

AMBIENT 125 °F 51.7 °C

Air Flow Entering


Model Total Compressor Sensible Capacity
Rate Air WBT
Capacity Power Input
76.0 ( 24.4 ) 78.0 ( 25.6 ) 80.0 ( 26.7 ) 82.0 ( 27.8 )
DMS cfm L/s °F °C MBh kW kW MBh kW MBh kW MBh kW MBh kW
63 17.2 189.2 55.5 25.2 139.7 40.9 151.1 44.3 162.5 47.6 173.8 50.9
65 18.3 196.2 57.5 25.3 127.8 37.5 139.2 40.8 150.6 44.1 161.9 47.5
6000 2831
67 19.4 202.8 59.4 25.5 115.7 33.9 127.1 37.3 138.5 40.6 149.8 43.9
69 20.6 209.1 61.3 25.7 103.4 30.3 114.7 33.6 126.1 37.0 137.5 40.3
63 17.2 194.6 57.1 25.3 151.6 44.4 164.7 48.3 177.7 52.1 190.8 55.9
65 18.3 201.8 59.1 25.5 138.0 40.5 151.1 44.3 164.1 48.1 177.2 51.9
7000 3303
67 19.4 208.6 61.1 25.7 124.2 36.4 137.2 40.2 150.3 44.0 163.3 47.9
69 20.6 215.2 63.1 25.9 110.2 32.3 123.3 36.1 136.3 40.0 149.4 43.8
260
63 17.2 199.0 58.3 25.4 163.0 47.8 177.7 52.1 192.4 56.4 199.0 58.3
65 18.3 206.3 60.5 25.6 147.8 43.3 162.5 47.6 177.2 51.9 191.9 56.2
8000 3775
67 19.4 213.3 62.5 25.8 132.3 38.8 147.0 43.1 161.7 47.4 176.4 51.7
69 20.6 220.2 64.5 26.1 116.8 34.2 131.4 38.5 146.1 42.8 160.8 47.1
63 17.2 202.6 59.4 25.5 174.0 51.0 190.2 55.8 202.6 59.4 202.6 59.4
65 18.3 210.0 61.6 25.7 157.2 46.1 173.4 50.8 189.7 55.6 206.0 60.4
9000 4247
67 19.4 217.3 63.7 26.0 140.2 41.1 156.5 45.9 172.7 50.6 189.0 55.4
69 20.6 224.4 65.8 26.2 123.0 36.0 139.2 40.8 155.5 45.6 171.8 50.4
63 17.2 238.3 69.8 42.2 174.1 51.0 187.1 54.9 200.2 58.7 213.2 62.5
65 18.3 246.3 72.2 42.7 160.1 46.9 173.2 50.8 186.2 54.6 199.3 58.4
7000 3303
67 19.4 254.1 74.5 43.1 145.8 42.7 158.9 46.6 171.9 50.4 185.0 54.2
69 20.6 261.7 76.7 43.5 131.4 38.5 144.4 42.3 157.5 46.2 170.5 50.0
63 17.2 247.1 72.4 42.8 191.5 56.1 207.0 60.7 222.4 65.2 237.9 69.7
65 18.3 255.6 74.9 43.2 175.1 51.3 190.5 55.8 206.0 60.4 221.5 64.9
8500 4011
67 19.4 264.0 77.4 43.6 158.5 46.4 173.9 51.0 189.4 55.5 204.9 60.1
69 20.6 272.0 79.7 43.9 141.6 41.5 157.1 46.0 172.5 50.6 188.0 55.1
340
63 17.2 253.9 74.4 43.1 208.0 61.0 225.8 66.2 243.6 71.4 253.9 74.4
65 18.3 262.9 77.1 43.5 189.3 55.5 207.2 60.7 225.0 65.9 242.8 71.2
10000 4719
67 19.4 271.6 79.6 43.9 170.3 49.9 188.1 55.1 205.9 60.4 223.8 65.6
69 20.6 280.1 82.1 44.1 151.2 44.3 169.0 49.5 186.8 54.8 204.7 60.0
63 17.2 259.3 76.0 43.4 223.7 65.6 243.9 71.5 259.3 76.0 259.3 76.0
65 18.3 268.5 78.7 43.8 202.9 59.5 223.0 65.4 243.1 71.2 263.2 77.1
11500 5427
67 19.4 277.6 81.4 44.1 181.6 53.2 201.7 59.1 221.8 65.0 242.0 70.9
69 20.6 286.5 84.0 44.3 160.2 46.9 180.3 52.8 200.4 58.7 220.5 64.6

Note :These capacities are gross ratings. For net capacity deduct the heat of the supply air blower motor kW x 3.415 = MBH
Refer to the appropriate Blower Performance table for the kW of the supply air blower motor.

Page 16
FAN PERFORMANCE DATA
Fan Performance Data

Packaged Air Conditioners


motors External Static Pressure in.wg. [Pa]
Model Fan Air Flow Rate
std Opt. 0.2 (50) 0.4 (100) 0.6 (149) 0.8 (199) 1.00 (249) 1.2 (299) 1.4 (349) 1.6 (399) 1.8 (448) 2.00 (498)
DMS Size kw kw cfm l/s RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW
3,750 1,770 544 0.53 615 0.63 681 0.75 743 0.88 805 1.02 864 1.16 921 1.32 976 1.48 1029 1.65 1082 1.83
4,500 2,124 618 0.81 679 0.94 737 1.07 792 1.19 846 1.34 897 1.49 948 1.66 997 1.83 1045 2.01 1092 2.19
150 15/15 3 4
5,000 2,360 644 1.05 703 1.20 757 1.33 810 1.47 860 1.62 908 1.78 955 1.95 1003 2.12 1048 2.31 1093 2.50
6,000 2,832 733 1.66 784 1.85 833 2.03 879 2.21 924 2.37 966 2.53 1009 2.69 1049 2.88 1090 3.07 1129 3.27
4,000 1,888 560 0.61 628 0.73 691 0.84 751 0.97 810 1.11 867 1.26 922 1.42 975 1.58 1027 1.75 1078 1.93
5,000 2,360 639 1.03 699 1.19 753 1.32 806 1.46 856 1.60 904 1.76 952 1.93 999 2.10 1044 2.29 1090 2.48
190 15/15 3 4
5,800 2,738 709 1.50 761 1.68 811 1.86 859 2.03 905 2.18 948 2.34 992 2.50 1033 2.68 1075 2.87 1116 3.07
6,500 3,068 772 2.03 820 2.22 866 2.42 910 2.62 952 2.80 995 2.98 1034 3.16 1073 3.33 1111 3.52 1149 3.72
5,400 2,549 644 1.17 701 1.33 754 1.49 806 1.65 855 1.79 902 1.94 947 2.11 992 2.28 1035 2.47 1079 2.66
6,400 3,021 727 1.81 776 2.00 824 2.19 870 2.39 914 2.58 957 2.75 999 2.93 1038 3.10 1077 3.28 1116 3.47
240 15/15 4 5.5
7,400 3,493 814 2.67 857 2.87 900 3.08 940 3.32 981 3.55 1020 3.77 1058 3.99 1096 4.21 1132 4.40 1167 4.58
8,400 3,965 906 3.80 944 4.03 982 4.26 1019 4.50 1055 4.76 1091 5.02 1126 5.28 _ _ _ _ _ _
6,000 2,832 468 0.95 521 1.11 566 1.26 611 1.42 656 1.60 701 1.78 747 2.00 792 2.23 837 2.48 881 2.73
7,000 3,304 512 1.37 560 1.56 606 1.75 644 1.93 682 2.10 720 2.30 758 2.50 796 2.70 836 2.95 875 3.20
260 18/18 4 5.5
8,000 3,776 553 1.88 600 2.12 640 2.33 680 2.55 717 2.75 750 2.96 783 3.16 816 3.37 849 3.60 882 3.83
9,000 4,248 601 2.56 642 2.81 683 3.07 720 3.31 754 3.55 789 3.79 819 4.02 848 4.24 877 4.47 906 4.70
7,000 3,304 512 1.37 560 1.56 606 1.75 644 1.93 682 2.10 720 2.30 758 2.50 796 2.70 836 2.95 875 3.20
8,500 4,012 573 2.18 617 2.43 658 2.66 699 2.90 732 3.12 766 3.34 800 3.56 830 3.78 860 4.00 890 4.22
340 18/18 5.5 7.5
10,000 4,720 656 3.41 696 3.72 731 4.00 767 4.28 802 4.55 832 4.81 862 5.08 892 5.34 919 5.59 945 5.84
11,500 5,428 735 4.98 769 5.33 803 5.69 834 6.01 865 6.33 896 6.65 924 6.96 952 7.26 _ _ _ _
 

Shaded areas represent oversize motors


Page 17
Packaged Air Conditioners

DRIVE AND PULLEY DATA R-407c

Low Static Drive Set


Motor Drive Packaged Fan Drive Packaged Belt
Unit
Pitch RPM Setting Center
Model Pitch Size
Pulley Bush Pulley Bush Dia. Range Dist.
DMS Min Max mm Min Max RPM mm mm
150 VAR 108 A1 1210 x 28 mm 78 102 SPA 250 1 2012 x 25 mm 250 546 714 680 495 1524
190 VAR 108 A1 1210 x 28 mm 78 102 SPA 224 1 2012 x 25 mm 224 609 797 710 597 1687
240 VAR 108 A1 1210 x 28 mm 78 102 SPA 212 1 2012 x 25 mm 212 644 842 750 597 1668
260 VAR 108 A1 1210 x 28 mm 78 102 SPA 280 1 2012 x 25 mm 280 488 638 600 597 1775
340 VAR 139 A1 1610 x 38 mm 109 133 SPA 355 1 2012 x 25 mm 355 537 656 680 597 1942

Standard Drive Set


Motor Drive Packaged Fan Drive Packaged Belt
Unit
Pitch RPM Setting Center
Model Pitch Size
Pulley Bush Pulley Bush Dia. Range Dist.
DMS Min Max mm Min Max RPM mm mm
150 VAR 108 A1 1210 x 28 mm 78 102 SPA 190 1 1610 x 25 mm 190 718 939 790 495 1430
190 VAR 108 A1 1210 x 28 mm 78 102 SPA 170 1 1610 x 25 mm 170 803 1050 920 597 1432
240 VAR 108 A1 1210 x 28 mm 78 102 SPA 160 1 1610 x 25 mm 160 853 1116 985 597 1432
260 VAR 108 A1 1210 x 28 mm 78 102 SPA 212 1 2012 x 25 mm 212 644 842 705 597 1668
340 VAR 177 A1 2012 x 38 mm 149 171 SPA 355 1 2012 x 25 mm 355 735 843 790 597 2003

High Static Drive Set


Motor Drive Packaged Fan Drive Packaged Belt
Unit
Pitch RPM Setting Center
Model Pitch Size
Pulley Bush Pulley Bush Dia. Range Dist.
DMS Min Max mm Min Max RPM mm mm
150 VAR 108 A1 1210 x 28 mm 78 102 SPA 150 1 1610 x 25 mm 150 910 1190 900 495 1367
190 VAR 108 A1 1210 x 28 mm 78 102 SPA 150 1 1610 x 25 mm 150 910 1190 1050 597 1571
240 VAR 146 A1 1610 x 38 mm 116 140 SPA 200 1 2012 x 25 mm 200 1015 1225 1120 597 1709
260 VAR 146 A1 1610 x 38 mm 116 140 SPA 265 1 2012 x 25 mm 265 766 925 850 597 1811
340 VAR 146 A1 1610 x 38 mm 116 140 SPA 250 1 2012 x 25 mm 250 812 980 900 597 1788
 

Page 18
Packaged Air Conditioners

ELECTRICAL DATA - 60 Hz R-407c

Model DMS-150
Condenser Supply Blower Motor Minimum Circuit Maximum Fuse
Compressors Electric Heater
Voltage Fan Motors Standard Extended Amperes Breaker Size
RLA Each LRA Each FLA Each FLA kW Amperes Amperes Amperes
- - 81.7 110
9 23.6 81.7 110
220 V / 3Ph / 60 Hz 25.3 135.0 6.8 11.0 14.2
18 47.2 81.7 110
36 94.5 112.3 150
- - 43.8 60
9 13.7 43.8 60
380 V / 3Ph / 60 Hz 13.2 100.0 3.9 6.4 8.2
18 27.4 43.8 60
36 54.7 65.0 90
- - 38.8 50
9 11.3 38.8 50
460 V / 3Ph / 60 Hz 10.8 80.0 4.3 5.7 7.5
18 22.6 38.8 50
36 45.2 55.2 70

Model DMS-190
Condenser Supply Blower Motor Minimum Circuit Maximum Fuse
Compressors Electric Heater
Voltage Fan Motors Standard Extended Amperes Breaker Size
RLA Each LRA Each FLA Each FLA kW Amperes Amperes Amperes
- - 91 125
220 V / 3Ph / 60 Hz 27.6 140.0 5.4 11.0 14.2 18 47.2 91 125
36 94.5 116.3 150
- - 53 70
380 V / 3Ph / 60 Hz 16.1 102.0 3.1 6.4 8.2 18 27.4 53 70
36 54.7 67.3 90
- - 40.1 60
460 V / 3Ph / 60 Hz 12.4 80.0 3.2 5.7 7.5 18 22.6 40.1 60
36 45.2 57.4 80

Model DMS-240
Condenser Supply Blower Motor Minimum Circuit Maximum Fuse
Compressors Electric Heater
Voltage Fan Motors Standard Extended Amperes Breaker Size
RLA Each LRA Each FLA Each FLA kW Amperes Amperes Amperes
- - 106.8 150
220 V / 3Ph / 60 Hz 32.1 237.0 5.4 14.2 19.0 18 47.2 106.8 150
36 94.5 119.5 150
- - 63.5 80
380 V / 3Ph / 60 Hz 19.3 160.0 3.1 8.2 11.0 18 27.4 63.5 80
36 54.7 69.1 90
- - 54.0 70
460 V / 3Ph / 60 Hz 15.7 130.0 3.2 7.5 10.0 18 22.6 54.0 70
36 45.2 59.1 80

Page 19
Packaged Air Conditioners

ELECTRICAL DATA - 60 Hz R-407c

Model DMS-260
Condenser Supply Blower Motor Minimum Circuit Maximum Fuse
Compressors Electric Heater
Voltage Fan Motors Standard Extended Amperes Breaker Size
RLA Each LRA Each FLA Each FLA kW Amperes Amperes Amperes
- - 106.8 150
220 V / 3Ph / 60 Hz 32.1 237.0 5.4 14.2 19.0 18 47.2 106.8 150
36 94.5 119.5 150
- - 63.5 80
380 V / 3Ph / 60 Hz 19.3 160.0 3.1 8.2 11.0 18 27.4 63.5 80
36 54.7 69.1 90
- - 54.0 70
460 V / 3Ph / 60 Hz 15.7 130.0 3.2 7.5 10.0 18 22.6 54.0 70
36 45.2 59.1 80

Model DMS-340
Condenser Supply Blower Motor Minimum Circuit Maximum Fuse
Compressors Electric Heater
Voltage Fan Motors Standard Extended Amperes Breaker Size
RLA Each LRA Each FLA Each FLA kW Amperes Amperes Amperes
- - 145 200
220 V / 3Ph / 60 Hz 45.7 255.0 5.4 19.0 25.2 18 47.2 145 200
36 94.5 145 200
- - 86.8 125
380 V / 3Ph / 60 Hz 27.1 155.0 3.1 11.0 15.6 18 27.4 86.8 125
36 54.7 86.8 125
- - 75.0 90
460 V / 3Ph / 60 Hz 22.9 145.0 3.2 10.0 13.6 18 22.6 75.0 90
36 45.2 75.0 90

Page 20
Packaged Air Conditioners

DIMENSIONAL DATA

DMS-150

Page 21
Packaged Air Conditioners

DIMENSIONAL DATA

DMS-190

Page 22
Packaged Air Conditioners

DIMENSIONAL DATA

DMS-240, 260 & 340

Page 23
Packaged Air Conditioners

TYPICAL WIRING DIAGRAM

Page 24
Packaged Air Conditioners

GUIDE SPECIFICATIONS

DESCRIPTION REFRIGERANT COMPONENTS

Standard Units shall be factory assembled, single Compressors


packaged, cool only, designed for outdoor mounted
installation. The 12.5, 16, 20, 22 and 28 ton units shall a. Compressors for all models shall be Hermetic Scroll.
have minimum EER ratings of 7.7. They shall have All compressors shall be internally protected with
built-in side duct connections for discharge supply and internal high pressure relief and over temperature
return. The units shall be factory wired, piped, charged protection. The compressors shall be mounted on
with R-407c refrigerant and factory tested prior to neoprene mounts to eliminate vibration from being
shipment. All unit wiring shall be both numbered and transmitted to the unit structure and cabinet.
colour coded.
Coils

UNIT CABINET AND FRAME a. Evaporator and condenser coils shall have aluminum
fins mechanically bonded to seamless internally
Unit cabinet shall be constructed of G90 galvanized enhanced copper tubes with all joints brazed.
steel, with exterior surfaces coated with a non- Condenser fin spacing shall be limited to 14 fins per
chalking, powdered paint finish, to meet ASTM inch to maximize heat transfer to minimize
B117 standards suitable for 750 hours salt spray test. blockage and high pressure operating condition,
The indoor blower and air supply section shall be special heresite coating shall be available as factory
insulated with an aluminum faced ½” thick, water options.
proof insulation or by 13mm Elastomeric insulation.
Cabinet panels shall be easily removable for servicing b. Evaporator and Condenser coils shall be of the direct
and maintenance. Full perimeter base rails shall be expansion, draw-thru, design. Coils shall be tested
provided to assure reliable transit of equipment, overhead up to a pressure of 250 psig (evaporator) and 450
rigging and fork lifting. Disposable 2” filters shall be psig (condenser).
furnished and be accessible through a removable access
door, sealed airtight. Condensate connection shall be Refrigerant Circuit and Refrigerant Safety
minimum of 1” FPT connection. components shall include

a. Thermostatic expansion valve with external


INDOOR (EVAPORATOR) F AN ASSEMBLY equalizing line.
b. Filter drier / strainer to eliminate any moisture or
Fan shall be a belt drive assembly and include an foreign matter.
adjustable pitch motor pulley (optional). Fan wheel shall c. Accessible service gauge connections on both
be DIDW type with forward curved High static blades, suction and discharge lines to charge, evacuate, and
dynamically balanced to operate smoothly throughout measure refrigerant pressure during any necessary
the entire range of operation. Airflow design shall be servicing or troubleshooting, without losing charge.
constant air volume. Bearings shall be lubricated for life. d. The refrigeration system shall provide at least 15°F
The evaporator motor shall be TEFC IP55 class F of sub-cooling at design conditions.
insulation. e. All models shall have two independent refrigerant
circuits.
OUTDOOR (CONDENSER) FAN ASSEMBLY f. Unit shall operate with conventional thermostat
designs and have a low voltage terminal strip for
Each unit shall have two condenser fans / motors. The easy hookup.
outdoor fans shall be of direct driven propeller type, g. Unit control board shall have on-board diagnostics
discharge air vertically and shall be dynamically and fault code display.
balanced for smooth operation. The outdoor fan motors h. Standard controls shall include anti-short cycle and
shall be TEAO IP55 with class F insulation. Motors low voltage protection, and permit cooling operation
shall have permanently lubricated bearings and shall down to 50°F.
have external overload protection. i. Control board shall monitor each refrigerant safety
switch independently.
j. Control board shall retain last 5 fault codes in
nonvolatile memory, which will not be lost in the
event of a power loss.

ELECTRIC HEATING - OPTIONAL

Nickel chromium electric heating elements shall be


provided as required by the application with 1 stage control
for 9 kW and 2 stage control, for 18 kW or 36 kW
capacities. The heating section shall have a primary limit
control(s) and automatic reset to prevent the heating
element system from operating at an excessive temperature.
Units with Electric Heating shall be wired for a single point
power supply.
Page 25
Packaged Air Conditioners

UNIT OPERATING CHARACTERISTICS EVERY 3 MONTHS

Unit shall be capable of starting and running at 125°F In addition to the monthly maintenance above, check the
outdoor temperature. The compressor, with standard belt tension of evaporator fan. A correct tension is indicated
controls, shall be capable of operation down to 50°F outdoor when the belt has a relaxation of approximately 10 mm to
temperature. 13 mm when pressed lightly with a finger.

EVERY SIX MONTHS


ELECTRICAL REQUIREMENTS
In addition to the maintenance done every three months:
All unit power wiring shall enter unit cabinet at a single
factory provided gland be capable of side entry. The condenser coils should be cleaned by spraying
water over it at low pressure or with a brush while
MAINTENANCE ensuring that the fins are not damaged.
Check all electrical connections and tighten them if
The Saber Packaged Air Conditioners are premium quality required.
machines with very low maintenance requirements. Clean all accessible electrical panels of dirt and dust.
Before cleaning the control panels, ENSURE that the
Compressors used in Saber Packaged Units are of Scroll electrical power to the unit is switched off.
type and are charged with the correct amount of refrigerant
and lubricating oil. Unless there is a leak in the system, no
topping up is generally required. EVERY 12 MONTHS
All bearings used in the fan shaft, fan motor and evaporator In addition to the maintenance done every six months:
fan motor are permanently lubricated for life. Lubrication is
therefore not a part of the periodic maintenance schedule. Use a proper cleaning cloth to clean fan blades and
motors.
Ensure that the unit is working properly by checking,
EVERY MONTH current, voltages, pressures and temperatures.
Check the earthing or grounding of the unit.
Remove the filters and blow compressed air over them Check the exterior of the unit for any signs of corrosion.
to get rid of loose dust. Visually inspect the filters
conditions, replace them with new ones of same sizes if Even though it is highly unlikely, if any corrosion that
required. is seen, should be removed by proper sanding the
Saber Packaged Air Conditioners are provided with a surface. Repaint the unit with proper touch up paint,
specially designed drain pan, for proper maintenance available from York.
check and clean blockages at drain connections if any. Check the unit for any unusual vibrations or noise,
locate the cause and rectify it by changing mounts, base
isolators etc as required

Page 26
Johnson Controls provides comfortable
environments wherever ou
Live, Work or Travel
Whether ’re at home, in a car, or in an o ce or workplace, chances are there’s a Johnson Controls
product or service near , helping to make r environment more comfortable, safe and sustainable.

Johnson Controls creates smart environments that improve the places where people spend most of their
time – their homes, workplaces and vehicles. We anticipate consumer needs, and then integrate
technologies, products and services to make life better and easier.

For Johnson Controls, sustain abilit matters at ever level and through our products, service operations and
communit involvement, we promote the e cient use of resources to bene t all people and the world. Our
triple bottom line o hat is, economic prosperit , environmental stewardship and social
responsibilit impacts each and ever aspect of our business. York products are now a premier brand
manufactured Johnson Controls. The acquisition of York, gives us a unique insight into designing HVAC
products that match r exact requirements. We provide solutions for t s most critical concerns - ener
e cienc , refrigerant alternatives and indoor air qualit .

Johnson Controls has a wide range of York products for residential, light commercial and commercial
applications. Our offering includes package & split air conditioners and heat pumps. In addition, Johnson
Controls offers chillers, air handling units, ventilation equipment and controls for larger projects.

Our advanced technol is leading the w in developing e cient and environment friendl solutions for
r homes, o ces and places of leisure.

Let us create the ideal environment for .

Technical Sales Guide # TSG-12.528-R407c-60(MEDIUM-14R01)


60 Hz - R407c MGK

We reserve the right to change in part or in whole the speci cations


without prior notice.

Al Salem Johnson Controls (Head O ce)


P.O. Box 15019 Jeddah 21444
Kingdom of Saudi Arabia
Te +966 12 690 0999
F +966 12 690 0909

S-ar putea să vă placă și