Sunteți pe pagina 1din 1

Sheet1

DRILL STRING DESIGN WORKSHEET


WELL # : 112 - 100 DEPTH : 6890 FT DATE : OCT.25/2006
2100 MT BHA 795 FT
(1) BUOYANCY FACTOR 242.41 MTR.
65.44 10.1 PPG 65.44 0.846
(2) BHA & "G" GRADE WEIGHT IN AIR
D/C 244.56 FT X 160 LBS/FT = 39,130 LBS
D/C FT X 161 LBS/FT = 0 LBS
HWDP 644.45 FT X 49.3 LBS/FT = 31,771.4 LBS
D/P 5"G 6605.00 FT X 20.9 LBS/FT = 138,045 LBS
D/P 5"S 423.25 FT X 21.5 LBS/FT = 9,100 LBS
7917.26
TOTAL = 218,045 LBS
(3) BHA & "G" GRADE WEIGHT IN MUD
218,045 X 0.846 = 184,392 LBS
(TOTAL F/2) (TOTAL F/1)

(4) MARGIN OF OVERPULL "G"


436150 0.9 392,535 184,392 0.8 166,514 LBS
Tensil Strengh Total F/ 3 (SF)

(5) "S" GRADE WEIGHT IN AIR


560760 0.9 504,684 0 LBS/FT = 0 LBS

(6) TOTAL STRING WEIGHT IN MUD


218,045 0 X 0.846 184,392 LBS
(TOTAL F/2) (TOTAL F/5) (TOTAL F/1)

(7) MARGIN OF OVERPULL "S"


561375 0.9 505237.5 0 0.8 404,190 LBS
Tensil Strengh Total F/ 6 (SF)

(8) MAXIMUM WEIGHT INDICATOR READING


184,392 166,514 50,000 400,906 LBS
(TOTAL F/3OR 6) (SMALLEST F/4&7) (B+TDS)

S-ar putea să vă placă și