School of Mechanical

INFLUENCE OFand Building sciences


MASONRY INFILL ON SHEAR WALL AREA TO FLOOR
AREA RATIO IN MID RISE RC STRUCTURES
xMr./Ms.
AXXXXXXV.N.L.S.A.P.Aishwarya,
XXXXXXXXXXXXX V.M.anasa and Dr. I.Yamini SreevalliXXXXXXXXXXX XXXXXXXXXX XXX
XXXXXXXXXXXXXXXXXXXX

`
ABSTRACT ANALYTICAL MODELS REFERENCES

Generally, the shear wall in a RC frame structure increase the flexibility, [1] Anthugari Vimala, Pradeep Kumar Ramancharla (2014). “Expended energy
but the presence of infill makes it difficult to predict the overall based damage assessment of RC bare frame using nonlinear pushover analysis”.
Urban Safety of Mega Cities in Asia 2014 (USMCA 2014),Report No:
behavior. Infill and shear walls together provide greater stiffness and
IIIT/TR/2014/-1.
increase the lateral strength of the structure.
[2] Ashwani Singh. (2015). “Effect of Shear Wall on Seismic Performance of RC
In this study, non-linear modelling of midrise structural frames including Open Ground Storey Frame Building”. Department of Civil Engineering of
National Institute of Technology, Rourkela.
shear wall and masonry infill could be carried out. Non-linear static 3-D FRAME MODEL WITH INFILL PLAN
[3] Burcu Burak; Hakki Gurhan; Comlekog. (2013). Effect of Shear Wall Area to
analysis may also be performed considering various shear wall to floor
Floor Area Ratio on the Seismic Behavior of Reinforced Concrete Buildings.
area ratio between 0% to 0.82%, to study the seismic behavior of the STOREY LEVEL SHEAR WALL AREA RATIO
1934 J. of Struct. Engg., 139, 1928-1937, ASCE.
structure due different lateral loads applied on the structure. From the 5 STOREY 0%
8 STOREY 0.19% [4] Hemanth B. Kaushik; Durgesh C.Rai; Sudhir K. Jain. (2009). Effectiveness of
pushover analysis results, it was observed that, for shear wall ratio of some stregthening options for masonry-infilled RC frames with open first storey.
0.33%
0.4%, the displacement and time periods of the structure was found to 0.39% J. Struct. Eng., 135(8), 925-937.
be constant for zone 3 and zone 5 criteria designed as per Indian 0.51% [5] John W. Wallace; Jack P. Moehle. (2014). Ductility and detailing requirements
standard code provisions. 0.71% of bearing wall buildings. J. Struct. Eng. 1992.118:1625-1644.
0.82% [6] K. H. Abdelkareem; F. K. Abdel Sayed; M. H. Ahmed; N. AL-Mekhlafy.
(2013). Equivalent strut width for modeling R.C. infilled frames. Pp 851-866.
OBJECTIVES RESULTS [7] Liborio Cavaleria; Fabio Di Trapania; Panagiotis G. Asterisb; Vasilis
Sarhosisc. (2017). Influence of column shear failure on pushover based
 To determine the interaction between infill and shear wall assessment of masonry infilled reinforced concrete framed structures: a case
SHEAR WALL RATIO Vs TIME PERIOD study. Soil Dynamics and Earthquake Engineering, 100 (2017) 98–112.
frame. 1 [8] Mitesh Surana; Yogendra Singh. (2015). Seismic performance of concrete-
TIME PERIOD (Sec)

0.8
 To study the effect of shear wall to floor area ratio on the shear-wall buildings in India. Proceedings of the Institution of Civil Engineers.
0.6 5S Z3
Paper 1500047. ICE publications.
seismic behaviour of the structure, in the presence of infill, 0.4 8S Z3
0.2 [9] Mitesh Surana; Yogendra Singh; Dominik Lang. (2016). Seismic performance
due different lateral loads acting on the structure. 0
5S Z5 of mid rise RC frame and frame-shear wall buildings designed for Indian codes.
0 0.2 0.4 0.6 0.8 8S Z5 Journal Of structural engineering. Research Gate Publication 303081317.
SHEAR WALL ARE TO FLOOR AREA RATIO (%) [10] Putul Haldar; Yogendra Singh; D.K. (2013), Effect of URM infills on seismic
METHODOLOGY vulnerability of Indian code designed RC frame buildings. Earthq Eng & Eng
Vib.11: 233-241.
SHEAR WALL RATIO Vs STORY DRIFT [11] Rahul RANA; Limin JIN; Atila ZEKIOGLU. (2004). Pushover analysis of a
0.6 19-story concrete shear wall buildings. Paper No. 133. 13th World Conference
on Earthquake Engineering.
DRIFT (%)

0.4 5S Z5
[12] Y.M. Fahjan; J. Kubin, M.T. Tan. (2010). Nonlinear Analysis Methods for
0.2 8S Z5
Reinforced Concrete Buildings with Shear walls. Gebze Institute of Technology,
0 8S Z3 41400 Gebze, Kocaeli, Turkey.
0 0.2 0.4 0.6 0.8 5SZ3
SHEAR WALL RATIO (%)

From the pushover analysis results, it was observed that, for shear wall ratio
of 0.4%, the displacement and time periods of the structure was found to be
constant. Shear wall area to floor area ratio between 0.3% to 0.7% has
shown elastic behaviour of RC structures with uniform drift profile and
constant displacement. Ms. V.N.L.S.A.P.Aishwarya Ms. V.manasa Dr. I.Yamini Sreevalli