KISWIRE-A RECOGNIZED PC PRODUCTS MANUFACTURER
KISWIRE is one of the world’ largest producers of stress relieved steel wire
and strand for prestressed concrete, commonly known as PC wire and strand.
KISWIRE PC wire and strand are produced at KISWIRE factories located in
Korea and Malaysia.

CHARACTERISTICS OF KISWIRE PC PRODUCTS


KISWIRE'S PC products are made to have high tensile, low relaxation characteristics, and other physical properties
required by various international specifications such as BS, ASTM, KS, JIS, AS, EN10138.

APPLICATIONS
PC WIRE PRODUCTS
Wire for prestressed concrete structures are used in construction
of buildings, high pressure concrete water pipes, railway sleepers, concrete piles and poles, etc.

PC STRAND PRODUCTS
Strand for prestressed concrete structures are used in construction
of buildings, bridges, domes of nuclear power plant, LNG container tanks, etc.

STEEL WIRE FOR PRESTRESSED CONCRETE


- BS 5896
Min.
Nominal Nominal 0.1% Load at
Nominal Nominal Breaking Elongation Max. % Relaxation
Tensile Steel Proof 1%
Diameter Mass Load at Max. After 1,000hrs From
Strength Area Load Elongation
Load
mm N/mm2 mm2 g/m kN kN kN % 60% Initial Load 70% Initial Load 80% Initial Load
1,670 12.6 98.9 21.0 17.5 17.9 3.5 1.0 2.5 4.5
4
1,770 12.6 98.9 22.3 18.5 19.0 3.5 1.0 2.5 4.5
4.5 1,620 15.9 125 25.8 21.4 21.9 3.5 1.0 2.5 4.5
1,670 19.6 154 32.7 27.2 21.8 3.5 1.0 2.5 4.5
5
1,770 19.6 154 34.7 28.8 29.5 3.5 1.0 2.5 4.5
1,670 28.3 222 47.3 39.9 40.2 3.5 1.0 2.5 4.5
6
1,770 28.3 222 50.1 41.6 42.6 3.5 1.0 2.5 4.5
1,570 38.5 302 60.4 50.1 51.3 3.5 1.0 2.5 4.5
7
1,670 38.5 302 64.3 53.4 54.7 3.5 1.0 2.5 4.5

- EN 10138 1&3
Nominal Specified
Characteristic Maxium Value Characteristic Min. Max.% Relaxation
Cross- Tensile Mass per Value of of value of Elongation
Diameter After 1,000hrs
sectional area strength meter maximum maximum 0.1% proof at Max.
force force force Load From
mm mm2 Mpa g/m kN kN kN % 70% Initial Load 80% Initial Load
5.0 19.6 153.1 30.8 35.4 27.1 3.5 2.5 4.5
6.0 28.3 1570 221.0 44.4 51.1 39.1 3.5 2.5 4.5
7.0 38.5 300.7 60.4 69.5 53.2 3.5 2.5 4.5
8.0 50.3 392.8 79.0 90.9 69.5 3.5 2.5 4.5
5.0 19.6 153.0 32.7 37.6 28.8 3.5 2.5 4.5
5.5 23.8 185.9 39.7 45.7 34.9 3.5 2.5 4.5
6.0 28.3 1670 221.0 47.3 54.4 41.6 3.5 2.5 4.5
6.5 33.2 259.3 55.4 63.7 48.8 3.5 2.5 4.5
7.0 38.5 300.7 64.3 73.9 56.6 3.5 2.5 4.5
5.0 19.6 153.1 34.7 39.9 30.5 3.5 2.5 4.5
5.5 23.8 1770 185.9 42.1 48.4 37.0 3.5 2.5 4.5
6.0 28.3 221.0 50.1 57.6 44.1 3.5 2.5 4.5
7.0 38.5 300.7 68.1 78.3 59.9 3.5 2.5 4.5
5.0 19.6 1860 153.1 36.5 42.0 32.5 3.5 2.5 4.5

2 PC WIRE & STRAND


pcwire&s 2007.2.15 11:37 AM 페이지4

KISWIRE'S PURSUIT FOR CONTINUOUS INNOVATION


To satisfy diversifyed and technically-advanced demands of today's market, KISWIRE is fully
committed to the development of innovative products. Our commitment for innovation have
been materialized in the forms of products such as:
● Wire for Prestressed Concete Cylindrical(High Pressure Water) Pipe.
● Strand used in construction of various parts of Nuclear Power Plants.
● Strand used in construction of Low Temperature LNG container tanks.
● Grease of Wax filled HIgh Density Polyethylene sheathed strand for CableStayed Bridges.
● Galvanized Wire for Suspension Bridges and Cable Stayed Bridges.

- ASTM A 421
Min. Min.
Nominal Nominal Nominal Min. Max.% Relaxation
Grade Stress at 1% Elongation
Diameter Steel Area Weight Tensile Strength After 1,000hrs From
Extension at Max. Load

in. in2 1bf per 1,000ft psi MPa psi MPa % 70% Initial Load 80% Initial Load
0.192 0.0290 98.4 250,000 212,500 4.0 2.5 3.5
1,725 1,465
0.196 0.0302 103.4 250,000 212,500 4.0 2.5 3.5
1,725 1,465
TypeWA
0.250 0.0491 166.8 240,000 204,000 4.0 2.5 3.5
1,655 1,407
0.276 0.0598 203.4 235,000 199,750 4.0 2.5 3.5
1,620 1,377
0.196 0.0302 103.4 240,000 204,000 4.0 2.5 3.5
1,655 1,407
TypeBA 0.250 0.0491 166.8 240,000 204,750 4.0 2.5 3.5
1,655 1,407
0.276 0.0598 203.4 235,000 199,750 4.0 2.5 3.5
1,620 1,377

- AS 1310

Min.
Nominal Max.% Relaxation
Nominal Tensile Strength Elongation
Diameter After 1,000hrs From
at Max. Load

mm Min. Max. % 70% Initial Load 80% Initial Load


1700 1950 2.5 2.0 3.0
3
1850 2100 2.5 2.0 3.0
4 1700 1950 2.5 2.0 3.0
1550 1800 2.5 2.0 3.0
5
1700 1950 2.5 2.0 3.0
1550 1800 2.5 2.0 3.0
7 1620 1870 2.5 2.0 3.0
1700 1950 2.5 2.0 3.0
1450 1700 2.5 2.0 3.0
8
1550 1800 2.5
The wire can be manufactured with smooth surface or indented surface according to customer's requirements.

PC WIRE & STRAND 3


pcwire&s 2007.2.15 11:37 AM 페이지5

PROCESSING

STEEL STRAND FOR PRESTRESSED CONCRETE


- BS 5896
Min.
Nominal Nominal 0.1% Load at
Nominal Nominal Breaking Elongation Max. % Relaxation
Grade Tensile Steel Proof 1%
Diameter Mass Load at Max. After 1,000hrs From
Strength Area Load Elongation
Load
mm N/mm2 mm2 g/m kN kN kN % 60% Initial Load 70% Initial Load 80% Initial Load
9.3 1,770 52 408 92 78 81 3.5 1.0 2.5 4.5
7-Wire 11.0 1,770 71 557 125 106 110 3.5 1.0 2.5 4.5
Standard 12.5 1,770 93 730 164 139 144 3.5 1.0 2.5 4.5
15.2 1,670 139 1,090 232 197 204 3.5 1.0 2.5 4.5
8.0 1,860 38 298 70 59 61 3.5 1.0 2.5 4.5
9.6 1,860 55 432 102 87 90 3.5 1.0 2.5 4.5
7-Wire
11.3 1,860 75 590 139 118 122 3.5 1.0 2.5 4.5
Super
12.9 1,860 100 785 186 158 163 3.5 1.0 2.5 4.5
15.7 1,770 150 1,180 265 225 233 3.5 1.0 2.5 4.5

- EN 10138 1&3
Nominal Specified
Characteristic Maxium Value Characteristic Min. Max.% Relaxation
Cross- Tensile Mass per Value of of value of Elogation
Diameter After 1,000hrs
sectional area strength meter maximum maximum 0.1% proof at Max.
force force force Load From
mm mm2 Mpa g/m kN kN kN % 70% Initial Load 80% Initial Load
5.6 9.70 1770 75.8 17.2 19.8 14.8 3.5 2.5 4.5
6.0 15.1 1770 117.9 26.7 30.7 23.0 3.5 2.5 4.5
15.2 139 1670 1086 232 267 200 3.5 2.5 4.5
12.5 93.0 726.3 165 190 142 3.5 2.5 4.5
12.9 100 781.0 177 204 152 3.5 2.5 4.5
15.2 139 1770 1086 246 283 212 3.5 2.5 4.5
15.3 140 1093 248 285 213 3.5 2.5 4.5
15.7 150 1172 266 306 229 3.5 2.5 4.5
15.2 165 1820 1289 300 345 258 3.5 2.5 4.5
9.3 52.0 406.1 96.7 111 83.2 3.5 2.5 4.5
9.6 55.0 429.6 102 117 87.7 3.5 2.5 4.5
11.3 75.0 585.8 140 161 120 3.5 2.5 4.5
12.5 93.0 726.3 173 199 149 3.5 2.5 4.5
1860
12.9 100 781.0 186 214 160 3.5 2.5 4.5
15.2 139 1086 259 298 223 3.5 2.5 4.5
15.3 140 1093 260 299 224 3.5 2.5 4.5
15.7 150 1172 279 321 240 3.5 2.5 4.5
12.7 112 874.7 208 239 179 3.5 2.5 4.5
1860
15.2 165 1289.0 307 353 264 3.5 2.5 4.5

4 PC WIRE & STRAND


pcwire&s 2007.2.15 11:37 AM 페이지6

- ASTM A 416
Min. Min. Min.
Nominal Nominal Nominal Max.% Relaxation
Grade Breaking Load at 1% Elongation
Diameter Steel Area Weight After 1,000hrs From
Strength Extension at Max. Load

in. sg. in2 (mm2) 1bf per 1,000ft(kg/1000m) 1bf (kN) 1bf (kN) % 70% Initial Load 80% Initial Load
1/4(0.250) 0.036(23.22) 122(182) 9,000 8,100 3.5 2.5 3.5
40.0 36.0
5/16(0.313) 0.058(37.42) 197(294) 14,500 13,050 3.5 2.5 3.5
64.5 58.1
Grade 250
3/8(0.375) 0.080(51.61) 272(405) 20,000 18,000 3.5 2.5 3.5
89.0 80.1
7/16(0.438) 0.108(69.68) 367(548) 27,000 24,300 3.5 2.5 3.5
120.1 108.1
1/2(0.500) 0.144(92.90) 490(730) 36,000 32,400 3.5 2.5 3.5
160.1 144.1
(0.600) 0.216(139.35) 735(1094) 54,000 48,600 3.5 2.5 3.5
240.2 216.1
3/8(0.375) 0.086(54.84) 290(432) 23,000 20,700 3.5 2.5 3.5
102.3 92.1
7/16(0.438) 0.105(74.19) 390(582) 31,000 27,900 3.5 2.5 3.5
137.9 124.1
Grade 270
1/2(0.500) 0.153(98.71) 520(775) 41,000 37,170 3.5 2.5 3.5
183.7 165.3
(0.600) 0.217(140.00) 740(1102) 58,600 52.740 3.5 2.5 3.5
260.7 234.6

- AS 1311

Nominal Min. Min.


Nominal Nominal Max. % Relaxation
Grade Steel Breaking Elongation
Diameter Mass After 1,000hrs From
Area Load at Max. Load

mm2 kg/1000m kN % 70% Initial Load 80% Initial Load


7.9 37 290 69 3.5 2.5 3.5
9.3 52 410 94 3.5 2.5 3.5
Regular Grade 10.9 71 555 125 3.5 2.5 3.5
12.7 94 740 165 3.5 2.5 3.5
15.2 139 1090 227 3.5 2.5 3.5
7.9 40 315 74 3.5 2.5 3.5
9.3 55 430 102 3.5 2.5 3.5
Super Grade 10.9 75 590 138 3.5 2.5 3.5
12.7 100 785 184 3.5 2.5 3.5
15.2 143 1125 250 3.5 2.5 3.5
Extra-HighTensile Grade 15.2 143 1125 261 3.5 2.5 3.5

PC WIRE & STRAND 5


pcwire&s 2007.2.15 11:37 AM 페이지7

SUSPENSION BRIDGE & CABLE STAYED BRIDGE

SUSPENSION BRIDGE & CABLE STAYED BRIDGE

GALVANIZED WIRE FOR BRIDGE CABLE


No Test Item Unit Suspension Main Cable Stay Cable
1. Diameter mm 5 7
2. Dia. Tolerance mm +/-0.06 +/-0.06
3. Ovality mm Max. 0.06 Max. 0.06
4. Area mm2 19.63 38.48
5. Weight Kg/m 0.154 0.302
6. Tensile Strength N/mm2 1570-1770/1770-1970 1570-1770/1770-1970
7. Yield Strength N/mm2 Min. 1180/Min. 1370 Min. 1180/Min. 1370
8. Elongation(250mm) % Min. 4.0 Min. 4.0
9. Elastic Modulus N/mm2 1.95-2.10X105 1.95-2.10X105
10. Bending - -Min. 4 (R=20mm) Min. 4 (R=18mm)
11. Straightness(1000mm) mm - Max. 30
12. Relaxation at 1,000hr 70% of B.S. % - Max. 2.5
13. Zinc Weight g/m2 Min. 300 Min. 300

6 PC WIRE & STRAND


pcwire&s 2007.2.15 11:37 AM 페이지8

PROCESSING

GALVANIZED PC STRAND FOR CABLE STAYED BRIDGE


No Test Item Unit 12.7mm 15.2mm 15.7mm
BARE STRAND
1. Diameter mm 12.7 15.2 15.7
2. Dia. Tolerance mm +0.4/-0.2 +0.4/-0.2 +0.4/-0.2
3. Weight kg/km 774 1102 1180
4. Breaking Strength kN 183.7 261 265
5. Yield Strength kN 165.3(1% Ext) 234.6(1% Ext) 225.0(0.1% Proof Load)
6. Elongation % 3.5 4.0 4.0
7. Relaxation at 1,000hr 70% of B.S. % Max. 2.5 Max. 2.5 Max. 2.5
8. Elasticity Modulus kN/mm2 192-208 192-208 192-208
9. Zinc Weight g/m2 190-320 190-320 190-320
HDPE COATED CABLE (Helix Type)
10. Diameter mm 14.9 17.4 18.9
11. Dia. Tolerance mm +0.4/-0.3 +0.4/-0.3 +0.4/-0.3
12. Thickness of HDPE Sheath mm 1.0 1.0 1.5
13. Grease Weight g/m2 Min. 8 Min. 8 Min. 8
HDPE CHARACTERISTIC
14. Tensile Strength kg/cm2 Min. 200 Min. 200 Min. 200
15. Elongation % Min. 350 Min. 350 Min. 350
16. Density g/m2 Min. 0.942 Min. 0.942 Min. 0.942
o
17. Softening Point C Min. 115 Min. 115 Min. 115
Data con be variable in accordance to custumer request.

PC WIRE & STRAND 7


pcwire&s 2007.2.15 11:37 AM 페이지1

KISWIRE INTERNATIONAL
SERVICE NETWORK

¡Æ KISWIRE LTD. (Seoul, Korea) ¡Æ KISWIRE CO. (Osaka, Japan)


Head Office : 475, Mangmi-Dong, Soo Young-Ku, Busan,Korea KISWEL Bldg., 4F 3-8-24, Nanbanaka, Namiwa-Ku, Osaka, Japan
TEL : 82-51-760-1700 / FAX : 82-51-757-7379 TEL : 81-6-6636-6607 / FAX : 81-6-6636-7751

Seoul Office : 20th floor, Jangkyo Bldg., 1, Jangkyo-Dong,


Chung-Ku, Seoul, Korea
¡Æ KISWIRE CO. (Tokyo, Japan)
TEL : 82-2-3166-114 / FAX : 82-2-3166-115 Ohtori Bldg., 7F 4-5 Oodenma-Cho,Nihonbashi Chuo-Ku, Tohyo, Japan
TEL : 81-3-3808-2839 / FAX : 81-3-3808-2835
Busan Office : 667-1, Buam-Dong, Busanjin-Ku, Busan, Korea
TEL : 82-51-1508-10 / FAX : 82-51-805-1511
¡Æ KISWIRE LTD. BEIJING
REPRESENTATIVE OFFICE (Beijing, China)
Room 19-5A, CITIC Building, 19 Jianguomenwai Street,
Beijing, China(100004)
TEL : 86-10-65931833/65931855 / FAX : 86-10-65931876

¡Æ QINGDAO TAK, LTD. (Qingdao, China)


118, Chengxi No. 4 Road Jimo, Qingdao, China
TEL : 86-532-859-0118 / FAX : 86-532-859-0119

¡Æ YANGTZE TAK LTD. (Jiangsu, China)


45 Zhongyang Road, Economic & Technological Development
Zone, Nantong City, Jiangsu, China(226009)
TEL : 86-513-598-0111 / FAX : 86-513-598-0119

¡Æ TREFILARBED KISWIRE LTD. (Shanghai, China)


Room C1109, Orient International Plaza, 85
Lou Shan Guan Road, Shanghai China(200336)
TEL : 86-21-6278-7712~3 / FAX : 86-21-6278-7710

¡Æ TREFILARBED KISWIRE LTD. (Asia Regional Office)


Suite 7.3A, 7th Floor, Menara Aik Hua Changkat Raja Chulan 50200
Kuala Lumpur Malaysia
Tel : 603-2381-4047, 603-2381-4048 Fax : 603-2381-4151

¡Æ KISWIRE SDN. BHD. (Johor, Malaysia)


Suite 1701, 17th Floor, City Plaza, Jalan,Tebrau, 80300 Johor, Malaysia
TEL : 60-7-333-0178 / FAX : 60-7-333-2475

¡Æ KISWIRE CORD SDN. BHD. (Johor, Malaysia)


Plo 475, Jalan Nibong, Kawasan Perindustrian Tanjung Langsat, 81700
Pasir Gudang, Johor, Malaysia
Tel. : 607 255 1475 Fax. : 607 255 2475

¡Æ KISWIRE TRADING(S) CO., LTD. (Singapore)


135 Cecil Street, #06-01 LKN Building, Singapore 069536
TEL : 65-227-0939 / FAX : 65-227-2297

¡Æ KISWIRE EUROPE B.V. (Dongen, Netherlands)


Metaalstraat 5 P.O. Box 365100 AA Dongen The Netherlands
TEL : 31-162-370230 / FAX : 31-162-370231

¡Æ TREFILARBED KISWIRE, L.L.C. (Ohio, U.S.A.)


202 Montors West Avenue Suite No. 325 Copley Township Ohio 44321
TEL : 1-330-670-8310 / FAX : 1-330-670-8429

¡Æ KISWIRE TRADING, INC. (New Jersey, U.S.A.)


460 Bergen Boulevard #120 Pallsades Park, NJ. 07650 U.S.A.
TEL : 1-201-461-8895 / FAX : 1-201-461-8021

¡Æ KISWIRE, INC. (Newberry, SC, U.S.A.)


257 Mawsons way, Newberry, SC 29108, U.S.A.
TEL : 1-803-321-0940 / FAX : 1-803-405-0307

¡Æ KISWIRE WEST INC. (LA, U.S.A.)


3450 Wilshire Blvd. Suite #314, Los Angeles, CA 90010
TEL : 213-386-5420 / FAX : 213-386-6981

Printed in December.2005 Cat No. : 051201 Revision : 1


Verify:

F-IC-2031 REV 11
DUBAI CENTRAL LABORATORY DEPARTMENT
DCL PRODUCT CONFORMITY CERTIFICATION SCHEME
SCOPE OF CERTIFICATION
FOR CERTIFICATE NO. CL15020270

S-ar putea să vă placă și