Sunteți pe pagina 1din 2

PROJ.

8239: CRPO FOR 10 JACKETS


MRJN-1020/1025 Platform Applied Loads.

Maximum Operating Boat Impact


Water Depth from Total Gravity Load on maximum wave height maximum Base Shear Maximum Accidental Boat Impact Load
Buoyancy load Load
Platform Designation Jacket Type DWG (from LAT) the platform
1 Year 100 Year 1 Year 100 Year East West South East West North South
(m) (MT) (MT) (m) (m) (MT) (MT) (MT) (MT) (MT) (MT) (MT) (MT) (MT)

MRJN-1020/1025 4- Legged 48.30 5393.87 637.71 5.00 10.20 190.99 571.89 275.33 280.43 331.41 575.13 526.18 673.02 648.55

MRJN-1020/1025 Platform Applied Loads. (With Crane Moments (Mx,My Modified)

Maximum Operating Boat Impact


Water Depth from Total Gravity Load on maximum wave height maximum Base Shear Maximum Accidental Boat Impact Load
Buoyancy load Load
Platform Designation Jacket Type DWG (from LAT) the platform
1 Year 100 Year 1 Year 100 Year East West South East West North South
(m) (MT) (MT) (m) (m) (MT) (MT) (MT) (MT) (MT) (MT) (MT) (MT) (MT)

MRJN-1020/1025 4- Legged 48.30 5393.87 637.71 5.00 10.20 153.27 527.78 275.33 280.43 331.41 575.13 526.18 673.02 648.55

Notes:-
1 The Base shear Reported above are the results of environmental ( Wave, Current and Wind ) only
2 The total gravity load on the platform included dead load, floor load, maximum live load and marine growth including contingencies.

MRJN-1020/1025 Platform Ultimate Pile Head Loads. (With Crane Moments (Mx,My Modified)

ULTIMATE PILE COMPRESSION LOADS (MN)


Water Depth from
Platform Designation Jacket Type DWG (from LAT) Geotechnical Report Operating Storm (1 Year) Extreme Storm (100 Year) Operating Boat Impact Accidental Boat Impact
FOS=2.0 FOS=1.5 FOS=2.0 FOS=1.5
(m) A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2

MRJN-1020/1025 4- Legged 48.30 21.66 21.59 9.01 8.46 24.66 26.72 15.67 12.89 24.75 24.91 11.19 13.33 28.77 28.55 17.61 17.24

ULTIMATE PILE TENSION LOADS (MN)


Water Depth from
Platform Designation Jacket Type DWG (from LAT) Geotechnical Report Operating Storm (1 Year) Extreme Storm (100 Year) Operating Boat Impact Accidental Boat Impact
FOS=2.0 FOS=1.5 FOS=2.0 FOS=1.5
(m) A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2

MRJN-1020/1025 4- Legged 48.30 NA NA NA NA NA 0.47 4.63 1.90 NA NA 2.19 0.27 0.13 0.22 6.89 10.28

MRJN-1020/1025 Platform Ultimate Pile Head Loads.

ULTIMATE PILE COMPRESSION LOADS (MN)


Water Depth from
Platform Designation Jacket Type DWG (from LAT) Geotechnical Report Operating Storm (1 Year) Extreme Storm (100 Year) Operating Boat Impact Accidental Boat Impact
FOS=2.0 FOS=1.5 FOS=2.0 FOS=1.5
(m) A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2

MRJN-1020/1025 4- Legged 0.00 21.04 20.69 7.95 8.09 24.66 26.72 15.67 12.89 24.75 24.91 11.19 13.33 28.77 28.55 17.61 17.24

ULTIMATE PILE TENSION LOADS (MN)


Water Depth from
Platform Designation Jacket Type DWG (from LAT) Geotechnical Report Operating Storm (1 Year) Extreme Storm (100 Year) Operating Boat Impact Accidental Boat Impact
FOS=2.0 FOS=1.5 FOS=2.0 FOS=1.5
(m) A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 B1 B2

MRJN-1020/1025 4- Legged 0.00 NA NA NA NA NA 0.47 4.63 1.90 NA NA 2.19 0.27 0.13 0.22 6.89 10.28
Geotechnical report reference:
(i) K-NPC-SAU-0033- (Rev 0)- Preliminary Engineering Report for MRJN 1020/1025

Notes
Compression: (i) Pile Ultimate load for operating storm condition = [ pile head load + submerged weight of pile +weight of soil plug] X2.0
(ii) Pile Ultimate load for extreme storm condition = [ pile head load + submerged weight of pile +weight of soil plug] X1.50
(iii) Pile loads are ultimate loads (with a factor of safety of 2.0 for Operating and 1.5 for Storm) and include 5% contingency.

Tension: (i) Pile Ultimate load for operating storm condition = [ pile head load - submerged weight of pile ] X 2.0
(ii) Pile Ultimate load for extreme storm condition = [ pile head load - submerged weight of pile] X 1.50
(iii) Pile loads are ultimate loads (with a factor of safety of 2.0 for Operating and 1.5 for Storm) and include 5% contingency.

MRJN-1020/1025 Platform Pile Penetrations.

Water Depth from DESIGN PILE PENETRATION (m)


DWG (from LAT) Pile Shoe
Platform Designation Jacket Type Compression Tension
Dia X thk
(m) A1 A2 B1 B2 A1 A2 B1 B2

42" x 1.75"
MRJN-1020/1025 4- Legged 48.30 80.00 80.00 55.00 55.00
A1, B1, A2 & B2

Notes:
(i) All piles are governed by compression loads
(ii) Minimum Pile Penetration required for lateral stability is 16.2m (Where Lateral Displacement & Rotation =0)

This is for guidance only and to be recalculated based on the actual soil capacity achieved during installation in case of refusal.

S-ar putea să vă placă și