Master PLC (i.e. Modbus RTU) is connected wirelessly Sentinel, also one discrete input signal and one
to the VSDs (i.e. Modbus Slaves) by means of a couple discrete output signal can be connected to each
of Wireless Sentinels working in serial to WiFi Wireless Sentinel.
converting mode (any serial asynchronous 8 bits
protocol is supported). This application allows Specifications
significant reduction in construction and installation
cost, and also the likelihood of problems inherent to • Power Voltage: 8-30 Vdc. Reverse polarity
wired networks like electromagnetic interference protected.
from VSD power cables to the RS-485 wiring in long • Power consumption: 700 mW average
distances, ground loops, power surges, atmospheric transmitting at maximum power, 200 mW in
discharges and many others. sleep mode reporting each 5 seconds.
• Serial channels:
The Wireless Sentinels can be connected in AdHoc o Serial data rates RS-232/RS-485:
mode (no need of WiFi routers) or in infrastructure 2.400, 4.800, 9.600, 19.200, 38.400,
mode (any industrial WiFi router / Access Point is 57.600, 115.200, 230.400 bps in serial to
supported). wireless converting mode.
As a Solar Powered Remote Terminal Unit (RTU). 4.800, 9.600, 19.200, 38.400 bps in
Modbus RTU slave mode.
o Serial transmission mode: Asynchronous "Half
or Full Duplex" in RS-232, “Half Duplex” in RS-
485.
o Serial data format: 8 Bits, even parity, odd
parity or no parity, one start bit, 1 or 2 stop
bits.
o Serial data interfaces:
RS485 two wires (A and B), “Half Duplex”.
120 Ω end of line termination resistor can
be enabled via switch. +-80V over-voltage
protection between terminals A/B to
ground. 40V (clamping) over-voltage
protection between ground and shield.
RS-232 available signals: TxD, RxD, GND.
• WiFi radio specification: XBee® Wi-Fi IEEE 802.11
bgn compatible radio operating between 2.4 to
2.5 GHz (13 channels available). +28.75 dbm (0.75
Watts) peak power.
In this application fire and/or gas (F&G) detectors are • Radio receiver sensitivity: -93 dBm to – 71 dBm.
deployed in an industrial plant. Up to two detectors • Battery charger:
can be wired (4-20 mA) to one Wireless Sentinel o Solar power input: 8 to 40 Vdc. Protected by
which also loads the battery from a solar panel. The resettable fuse against reverse polarity.
Wireless Sentinel works in RTU mode as a Modbus o Maximum battery charging current: 900 mA
RTU Slave reporting the F&G detectors status to a @ 36 V. Internally protected by 1A fast acting
master PLC which is connected serially to a Wireless fuse.
Sentinel working as a serial to WiFi converter. o Battery type: Sealed lead acid or GEL.
o Floating voltage: 13.5 Vdc for 12 Vdc o 12,25 cm (Height) x 2,26 cm (Width) x 9,9 cm
batteries, 27 Vdc for 24 Vdc batteries (Battery (depth)
voltage depends on the model). • Enclosure:
o Maximum battery voltage: 14.4 Vdc for 12 o Material: Polyamide plastic
Vdc y 28 Vdc for 24 Vdc (Battery voltage o Flammability according UL 94: V0
depends on the model). • LEDs indicators:
• Inputs and Outputs: o Power-on: Green steady.
o Discrete Input: o A – Tx/Rx:
Number of inputs: 1 Amber blinking at 1Hz: indicates the
Nominal Voltage: 24 Vdc Wireless Sentinel is associated either with
On state voltage: 8 to 30 Vdc an Access Point (when working in
Off state voltage: 0 to 1 Vdc infrastructure mode) or with another
On state current: 0.3 mA @ 8Vdc, 1.4 mA Wireless Sentinel (when working in AdHoc
@30Vdc mode).
Off state current: < 0.25 mA Amber Steady: Wireless Sentinel is waiting
Response time: 20 mS (de-bouncing filter) for association.
Reverse polarity protected. Amber off: Wireless Sentinel radio is not
Electrical isolation: up to 5000 Vrms configured.
(optically coupled). Green blinking: Data is being received or
o Discrete Output: transmitted over the air.
Number of inputs: 1
Maximum voltage: 60 Vdc
Maximum current: 300 mA Wiring
Off state current: < 1 µA
Wireless Sentinel is equipped with four terminal
Voltage free output.
blocks each one having four positions or terminals as
Response time: 3 mS
shown in the next figure.
Current protection: 285 mA @ 2s
Isolation: 2500 Vrms (Optically coupled)
Output impedance: 10 Ω
o Analog Inputs:
Number of inputs: 1 or 2 (depending on
the model)
Input range and resolution:
0 to 21.5 mA – 21 mA/Count (10 bits)
0 to 1 Vdc – 1.05 mV/Count (10 bits)
Input impedance: 250 Ω max
Low pass filter: 30 Hz compatible with
HART protocol transmitters
Scan time: 3 mS minimum
Accuracy: +- 0,5% measured value
Current protection: 100 mA @ 5s
(resettable fuse)
Isolation: None
• Operating temperature: -30°C to 70°C