E1/T1 Manager

EADS TETRA SYSTEM RELEASE 5.0 – 5.5


E1/T1 Manager

DN0570254-03-0en
03/2010
The content of this document and its appendices and any information provided (all together "document") is for information
purposes only and is subject to change without notice. The document only specifies the products and services identified in the
document. The document is confidential and contains legally privileged information.

The document is only intended for the use of the recipient and the customer whose representative the recipient is, and may
only be used for the purposes for which the document is submitted. The document or any part of it may not be reproduced,
disclosed or transmitted without the prior written permission of Cassidian Finland Oy.

Cassidian Finland Oy will reasonably ensure that the information provided in the document is free from material errors and
omissions. However, the suggestions, directions, comments and statements made in the document (e.g. regarding the
compatibility, performance and functionality of mentioned hardware and software) are not intended to be and cannot be
considered as binding. The customer assumes full responsibility for using the document or any part of it. All comments and
feedback are welcomed by Cassidian Finland Oy and are used as part of the continuous development and improvement of
Cassidian’s products, services and the document.

Cassidian Finland Oy disclaim and exclude all representations, warranties and conditions whether express, implied or statutory,
including but not limited to the correctness, accuracy or reliability of the document, or otherwise relating to the document.
Cassidian Finland Oy total liability for any errors in the document is limited to the documentary correction of errors. Cassidian
Finland Oy will not be liable for any direct or indirect damages arising from the use of the document or otherwise relating to
the document.

Cassidian logo is a registered trademark of Cassidian. Other product names, trademarks or other identifiers mentioned in the
document may be trademarks of their respective companies and are mentioned for information purposes only.

Copyright © 2011 Cassidian Finland Oy, all rights reserved.

CASSIDIAN
Metapole
1 boulevard Jean Moulin
CS40001
78996 Elancourt Cedex - FRANCE
Email: PMRsupport@cassidian.com

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

2(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
Contents

1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2 System requirements and installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3 User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

4 Operating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

5 Tests, Alarms, and Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 3(23)
List of Tables.
Table 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

4(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
List of Figures.
Figure 1 E1/T1 Manager installation start-up screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 2 Nokia Siemens Networks SiteWizard software installation options . . . . . . . . . . . . . . . 11
Figure 3 E1/T1 Manager Main Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 5(23)
DOCUMENT AMENDMENTS

VERSION DATE COMMENTS CHAPTER


UPDATED
03-0 03/2010 The name of the Nokia E1/T1 Manager has been
changed into E1/T1 Manager throughout the document.
Nokia has been replaced by Nokia Siemens Networks
throughout the document.
All the 3 figures have been updated.
02-1 02/2009 New EADS sales code replacing Nokia code. 1

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

6(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
CHAPTER

Overview
The E1/T1 Manager manages the FXC E1/T1 and FXC E1 cards installed in TBS (TETRA base
station). The E1/T1 Manager is used locally as a stand-alone transmission manager.

The E1/T1 Manager is included in the Nokia Siemens Networks Sitewizard 4.15 or later package
which can be downloaded via the Nokia Siemens Networks Online Service (NOLS) or delivered on a
CD-ROM (the EADS sales code for “Sitewizard for FXC Management” is DA0780).

There are two different hardware versions of the FXC transmission cards: FXC E1/T1 and FXC E1.
For more details, refer to the FXC E1 and FXC E1/T1 Transmission Unit Description for TETRA,
dn05100057. Cross-connections can be made at 8k, 16k, 32k, 64k, n x 8k, n x 64k, and 2M granularity.
A connection can be made between 2M interfaces and also between a 2M line interface and a D-bus
interface. The D-bus is the internal interface of the TBS. Chained, loop, and star-network topologies
are supported.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 7(23)
PAGE INTENTIONALLY LEFT BLANK

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

8(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
CHAPTER

System requirements and installation


See also the ’Read Me’ file in the installation file set for further information.

PC requirements

Operating system: Microsoft® Windows XP, 2000, 2003 Server

System memory: XP, 2000 32 MB

Monitor: SVGA, min. 800 x 600 resolution

Disk space: 50 MB

Accessories: CD-ROM drive, Windows-compatible mouse or pointing device, 9-pin serial port, and
LMP cable (PC – FXC unit), (optional) Windows-compatible printer.

Installation

The E1/T1 Manager is delivered on the Nokia Siemens Networks SiteWizard CD-ROM together with
other Nokia Siemens Networks Element management applications. Use the set-up program on the
CD-ROM to install the manager into your computer. Note that you must have Administrator rights
for the computer to do this.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 9(23)
Figure 1 : E1/T1 Manager installation start-up screen

Existing SiteWizard supported applications, if any, must first be uninstalled on the PC before installation
of the E1/T1 Manager software.

Check the Uninstalation of SiteWizard supported applications box before clicking the Next > button.

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

10(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
Figure 2 : Nokia Siemens Networks SiteWizard software installation options

As default the whole Nokia Siemens Networks SiteWizard software bundle would be installed. In the
EADS TETRA System only the E1/T1 Manager and GCS 4.2 SP3 need to be installed. Uncheck all
other boxes before clicking the Next > button.

After this follow the instructions on the screen.

The setup program copies files to the target disk and makes all required modifications to the Windows
registry. After installation the manager is ready for use (the computer may require rebooting first).

Uninstallation

To uninstall the manager, use the standard Windows procedure. Click the Start button in the toolbar
at the bottom of the screen, then select the →Settings | Control Panel menu command. Double-click
the →Add/Remove Programs icon, click the →Install/Uninstall tab and follow the instructions in the
lower part of the →Install/Uninstall page.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 11(23)
PAGE INTENTIONALLY LEFT BLANK

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

12(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
CHAPTER

User Interface
User Interface overview

The user interface consists of a Menu Bar, child windows, a Toolbar, a Status Bar and dialog boxes.
The user interface follows an object-oriented principle, where available operations are provided by
means of context sensitive popup menus. All supported operations are also available in the menu bar.

Each child window has a context sensitive popup menu that can be activated by clicking the right
mouse button. This menu gives available operations in the selected window. The child window may
have a specific area with its own context sensitive menu.

As some child windows require data retrieved from the node, this may cause some delay before the
contents of the window can be seen. Only one instance of each child window can be open at a time.

You can modify information included in the dialog boxes. In the connect mode, clicking the OK or
→Apply button will send the modified data to the node. In the file mode, selecting the →Save / Save As
menu command saves the modified data in a file.

All operations in the manager are accessible by mouse or keyboard. The toolbar also provides buttons
for most frequently needed commands.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 13(23)
Figure 3 : E1/T1 Manager Main Window

Menu Bar

Menu bar provides access to all features available for any given state of the Element manager. Menu
item availability depends upon the following factors: Whether connected or not, whether the manager is
in file (virtual) mode and user access level. Depending on the situation, some menu items may be
disabled. All menu items have a hint text that appears on the status bar

Toolbar

The toolbar provides short-cuts to commonly used menu options. The toolbar is normally displayed
below the menu bar, and it cannot be overdrawn by the child windows (an exception is the dockable
window). The toolbar is fixed (cannot be floated). The functions of the toolbar can also be executed by
a menu command (from a popup menu or the menu bar).

You can choose to display or hide the toolbar by switching it on and off using the Tools | Toolbar menu
command. The toolbar is on by default. You can also choose whether the toolbar has large or small
(default) icons using the →Tools | Large Icons menu command.

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

14(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
Each toolbar item has a toolbar tip text. The tip text is a text box that appears below the toolbar.

Status Bar

The status bar appears at the bottom of the application’s main window and the child windows cannot
overdraw it. The status bar is used to display context related messages. The status bar also indicates
the state of the manager whether it is connected to the unit.

The messages displayed in the status bar are the following types:

help message, which relates to the element currently pointed at (a menu option or a button on the
toolbar)

status message, which informs you about the completion of an action, for example

The status bar can be toggled on and off using the Tools | Status Bar menu command. The status bar
is on by default.

Some of the child windows may also have a status bar of their own.

Context Sensitive Popup Menus

The child windows support a context sensitive popup menu if related menu activities are available.
Popup menus provide access to essential operations. The menus are defined with each window
specification. If an object in the window is selected (by clicking the right mouse button), the context
sensitive menu for that object is activated. If no object is selected (by clicking the right mouse button),
the default popup menu for the window is opened.

The popup menu is also accessible by pressing the Shift+F10 keys or the special popup menu button
on Win95 keyboards. One item in the context sensitive menu can be a default item. It is indicated by
bold font. The operation behind a default item is activated by double-clicking the selected object with
the left mouse button. This corresponds to pressing the Enter key.

Keyboard Access

The keyboard can be used to control the manager. All functions of the manager are accessible using
the keyboard. Exception: clicking a list control column header to perform a sort operation.

The tab key is used to move the cursor in child windows and dialog boxes. The most frequently
used commands have short-cut keys.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 15(23)
Table 1 :

Command Short-cut
File | New Ctrl + N
File | Open Ctrl + O
File | Save Ctrl + S
File | Save As Ctrl + Shift + S
File | Print Ctrl + P
File | Exit Alt + F4
Connection | Connect Locally Ctrl + L
Connection | Refresh All Ctrl + R, F5

Progress Indication

You must wait while the manager communicates with the node. The length of this delay depends on the
amount of information transferred. An hourglass is shown to indicate that an operation is expected to
take place in a relatively short time. A progress dialog box is shown to indicate a lengthy operation.
The manager provides as accurate information as possible about operation progression.

Progress dialog box

This is the default progress animation shown when a lengthy operation is running. The bottom of the
dialog box includes a progress bar and a percentage value showing progress.

Detailed Progress dialog box

You may expand this dialog box to show more detailed information about the operation in progress.
The expanded dialog box contains an additional text box that receives information about the currently
ongoing operation.

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

16(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
CHAPTER

Operating
Connecting locally
Connect the MMI cable to the LMP (Local Management Port) adjacent to the FXC E1/T1 unit.
Select the Connection | Connect Locally menu command. A connection to the unit is established using
the fixed LMP address and default port / speed. You can change the port / speed in the Manager
Options dialog box.

Adjusting Service Interface Settings


1. Connect to the unit or open a node file.
2. Select the Configuration | Service Interface menu command to open the Service Interface dialog
box.
3. Select the Port Settings tab.
4. Adjust the Baud Rate of LMP.
Opening a Node File
1. Select the File | Open menu command. A modified →Open dialog box will open. The top part of
the dialog box contains a list of files you can open. The bottom part of the dialog box contains
information about the selected file.
2. Select the filename of the file you wish to open. If necessary, you may use the browse function
to search for the file.
3. Click the Open button to open the desired file.
Creating a New Node File
1. If you are connected to a node or file, close the Equipment window.
2. Select the File | New menu command.
3. The Equipment dialog box will open. Select the type of card and click OK.
4. The Equipment window will open and you can adjust the settings.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 17(23)
5. Select the File | Save menu command to save the settings in a file
Saving an old node file
Select the File | Save menu command to save an old node file. The file will be saved under the
current filename.

Saving a new node file


1. Select the File | Save As menu command to save a new file. A modified →Save As dialog box will
open. The top part of the dialog box contains the directory tree where you can save the node file.
The bottom part of the dialog box contains information about the current node file.
2. If necessary, click the Edit button to edit the file information.
3. Enter the new filename in the top part of the dialog box. If necessary, use the browse function to
locate the desired directory.
4. Click the Save button to save the node file in the desired directory.
Sending a Node File to the unit
1. Select the File | Open menu command to open a node file for editing or select the →File | New
menu command to create a new node file.
2. Select the Tools | Options menu command to open the Manager Options dialog box.
3. Set the Local Connect Parameters, Port and Speed.
4. Select the Connection | Send All menu command.

CAUTION
When selecting this option, the FXC resets itself and the connection to the DXT and ongoing calls will
be terminated before the new settings are taken into use.

A node file can only be sent via the LMP.

Downloading and Activating Software


You can download software to the unit and activate the new software.

Downloading software
1. Select the Maintenance | Unit Software menu command to open the standard →Unit Software
dialog box.
2. Click the Download button to open the →Open dialog box where you can select a file to be
downloaded.
3. Browse through the available files and select the file to be downloaded.
4. Click the Close button.
Activating downloaded software
1. Select the Maintenance | Unit Software menu command.

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

18(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
2. Click the Activate button to activate downloaded software.
3. Click the Close button.

Cross-connections
The cross-connections user interface is accessible only through the Cross-connections window. Only
one Cross-connections window can be open at a time.
Note
Configuration instructions are in theCommissioning the TB3 document, dn04153477.

The Cross-connections window is split into two parts. An upper window includes a cross-connections
list view showing connection information in text format. A lower window includes a cross-connections
graphical view showing how a connection "progresses" from one interface to another. The
Cross-connections window contains tabbed pages: Active bank and Inactive bank. The
cross-connections can be added or modified only in the inactive bank. The graphical view can be used
to add cross-connections. Alternatively the buttons in the cross-connection inactive bank tab can be
used to perform these tasks.
All the active cross connections are shown in the active bank tab and all the inactive cross-connections
are shown in the inactive bank tab.
Clicking the right mouse button over an item in the list view opens a popup menu. Selecting the
Properties menu command in the popup menu opens the Cross-connection Properties dialog box,
which displays the properties of the selected cross-connection. Cross-connections can only be edited
in the inactive bank. It is possible to print information from the Cross-connections list by selecting the
File | Print menu command.
Adding cross-connections to the unit:
1. Connect to the unit or open a node file.
2. Select the Configuration | Cross-connections menu command to open the Cross-connections
window.
3. Select the inactive bank.
4. Click the Add Cross-connections button to open the →Add Cross-connection Wizard – TX1/RX1
dialog box.
5. Select the desired interface by clicking the interface symbol.
6. Fill in the information for the first termination point. Click the Next button.
The Add Cross-connection Wizard – TX2/RX2 dialog box will open.
7. Fill in the information for the second termination point. Click the Next button.
If the cross-connection type is Protected Bidirectional, the Add Cross-connection Wizard –
Protecting TX/RX dialog box will open where you can fill in the information for the protecting

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 19(23)
interface. The →Overview dialog box will open. Depending on the cross-connection type, the
fields in this dialog box will be enabled as follows:

8.

a. If the cross-connection type is Bidirectional Masked, the Mask Properties controls are
enabled. Fill in the →Mask information.

b. If the cross-connection type is Protected Bidirectional, the Protection Information controls


are enabled. Click the →Condition button to open the →Condition dialog box, where you
can specify the condition information. If the Condition type is Equal, the dialog box contains
two tabbed →Condition pages. If the type is Priority, it contains only one tabbed Condition
page. Fill in the condition information. Click the →OK button.

c. If the cross-connection type is Unidirectional Fixed Data, the Fixed Data control is enabled.
Fill in the fixed data. Ensure that the existing cross-connections are copied from the active to
the inactive bank where they can be modified. The modified cross-connects in the inactive
bank can be taken in use by activating them.

9. Click the Finish button. The →Add Cross-connection Wizard dialog box will close and you will
return to the →Cross-connections window, where the new cross-connection appears in the
list in the upper part of the window.

Printing

1. Select a window:

Equipment window (to print Identifications dialog box information and information about nodes)

Cross-connections window (to print a list of connections)

Alarm window (to print a list of alarms).

2. Click the Print button or select the File | Print menu command.

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

20(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
CHAPTER

Tests, Alarms, and Statistics


Measurements
The Measurements dialog box allows you to view measurements of an E1/T1 unit. The values are
read from the unit, when the dialog box is opened. The →LIF1 (LIF2, LIF3, LIF4) frame shows the
line measurements for each interface in read only fields. Besides manual refreshing also automatic
refreshing can be selected at specified intervals. If the value is zero, auto-refreshing is turned off.

Interface Loops
The Interface Loops dialog box allows you to view and set the status of interface loops. The status
of the interface loops is read from the node when the dialog box is opened. To set the status of an
interface loop, select the type of loop using the option buttons in the →Loop Type frame. Only one type
of loop can be active at a time. Once the new loop is activated, click the →Send button to send the
settings to the node and read the status from the node. The →Refresh button allows you to read the
status of interface loops from the node.

Alarms
The Alarms window allows you to view current alarms coming from the node and alarm history. The
window is divided into four views, Node Structure, Active Alarms, Alarm History, and Filters And
Command. The →Alarms window is only available in the connected mode. Alarms are read from the
node when the →Alarms window is opened. Alarm monitoring can be set to retrieve alarms from the
node after a certain time interval. Alarms are not stored permanently - they are deleted when the
→Alarms window is closed. If you wish, you can store alarms in a file by selecting the →File | Save
menu command. You can also print a list of alarms by selecting the →File | Print menu command.
The Print Preview function is also supported. You can also view alarm history (cleared alarms are
then shown in the list).
The Node Structure view shows the logical and hierarchical structure of the connected equipment. This
view acts as a location filter for the alarms or events. Any item in the tree can be selected to view the
active alarms and alarm history of that location. The colour of the alarm bell indicates the worst level of
severity of an alarm at the location.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 21(23)
The Active Alarms view shows the location filter and time of the last refresh operation, i.e., the time
when the currently displayed alarms were read.

The Alarm History view shows the location filter and time of the last refresh operation, i.e., the time
when the currently displayed alarms were read. Severity of an alarm can be Critical, Major, Minor or
Warning. A coloured bell in front of the alarm indicates severity.

Statistics
The Statistics dialog box allows you to view and clear the statistics counters of an E1/T1 unit, excluding
the reset counters. The values of the counters are read from the node when the dialog box is opened.

The Action box identifies actions that can be performed. The following actions are supported for
FXC E1 and FXC E1/T1:

Refresh all counters from the node. If this action is selected, all counters are refreshed. Click the
Refresh button to start the action.

Reset Signal Quality Counters. If this action is selected, all Signal Quality Counters are cleared. Click
the Reset button to start the action. After resetting, all counters are refreshed from the node.

Reset Error counters. The Error counters frame contains read only fields with the values of the error
counters of the interface currently selected in the Action frame.

Show statistics counters for LIF. If this action is selected, the statistics counters for LIF are displayed.
Click the Show button to start the action. The error counters for Line Code Violations and Controlled
Slip Events are supported by FXC E1 and FXC E1/T1 cards.

CPU counters. The CPU counters frame displays the number of Hardware Resets.

DN0570254-03-0en EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager

22(23) This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission.
Glossary

For glossary, refer to Glossary, dn00126469.

EADS TETRA System Release 5.0 – 5.5 - E1/T1 Manager DN0570254-03-0en

This document is the property of Cassidian Finland Oy and should not be copied or circulated without permission. 23(23)