Speaker:
Friedrich W. Bremecker
Teamleader Sales, DIAL GmbH
BS 12464
• The BS12464 ask for further data than just average illuminance level or
glare
1
4.2 Luminance Distribution Measures
• The luminance distribution in the visual field controls the adaptation
level of the eyes which affects task visibility.
Ceiling
ρ = 0.7 - 0.9
Em = 30 lux, Uo ≥ 0.1
Walls
ρ = 0.5 - 0.8
Em = 50 lux, Uo ≥ 0.1
0,5m
2
4.3 Illuminance
Task Background
area area
≥3m
≥0.5m
Immediate
surrounding
area
0,5m
0,5m
3
A design example in a small assembly hall
4
Main room surfaces
5
4.6 Lighting in the interior space
Modelling
Ec/Eh of 0.30 – 0.60 at 1.2m above floor is an indicator of good modelling
6
Lighting Energy Numeric Indicator, LENI
Arrangement of luminaires
7
What LENI takes into account
Energetic optimization
8
BIM Building Information Modelling
BIM:
Definition:
What do we mean by a door?
Function:
What are the properties of a door?
Performance:
What must the door be able to do?
CAD:
Only lines
• The lighting designer works out the lighting layout and passes this
information to the architect / electrical engineer
• The lighting designer has to provide data about the products used
9
The BIM process of lighting design
Thermal Stress
analysis analysis
BIM model
• Any program can be used. All programs share the same data.
• The BIM data is the IFC data model
Interoperability in DIALux
10
First example using DDS-CAD
11
Using STF / gbXML in DIALux
• The lighting designer does not need a BIM CAD software (Revit,
Vectorworks, Microstation…)
• The lighting industry provides DIALux PlugIns. The product data is used
to be exported to the BIM file / software
12
Lighting design and LED’s
• LED luminaires are nothing special for a state of the art software
– High efficiency
– Long maintenance cycles
– Wide variety of available light colours
– Good colour rendering
– Controllability
– Small size
– Modularity
Photometric data
13
Relative vs. Absolute photometry
• Data for the luminaire independent from the lamp used during the
testing
• Data normalized to 1000lumens
• Light output ratio (LOR)
• Data can be adapted to changes
• The designer can use a specific lamp flux
There is no lamp!
Absolute photometry
• A lot of confusion with data from far east and from the US
14
Photometric data
• What is missing?
Photometric data
• What is missing?
15
Photometric data
Solution:
LED luminaires with complex photometric
data should be presented in electronic
catalogues that support the specific
features of SSL lighting products
Source: Philips
16
Download DIALux from: www.dialux.com
Find luminaires on: www.lumsearch.com
Find video tutorials at: http://www.youtube.com/user/TheDIALux