Sunteți pe pagina 1din 255

2008 Product Catalogue

Telephone: 01707 282880


Post Sales Technical Support / Spares and Warranty: 0870 3000 300
email: air.conditioning@meuk.mee.com
web: www.mitsubishielectric.co.uk/aircon

UNITED KINGDOM Mitsubishi Electric Europe Air Conditioning Systems Division


Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England.
General enquiries Telephone: 01707 282880 Fax: 01707 278674
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland.
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2008. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V.
The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement.
Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract.
All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

2008 Product Catalogue


Printed in April 2008
SAP No. 214760

A comprehensive range of Air Conditioning


www.greengatewayinitiative.co.uk Systems from Mitsubishi Electric Features Key
Designed by Square Bear Ltd 01604 899099. Square Bear Ltd are committed to using FSC certified paper and printers, wherever possible.

The laminate used on this brochure is environmentally friendly, recyclable and biodegradable
the name Mitsubishi is Mitsubishi Electric Partner Programme
synonymous with excellence Open to all contractors - large or small - the Mitsubishi Electric Par tner Programme offers contractors a
totally new and unique set of benefits. There are two categories within the programme - Accredited Installer
and Business Solutions Partner - these levels being a straight-forward reflection of the Partner’s
stage of growth, with all customers signing up to the programmes standards and committing to
Known the world over, Mitsubishi is a trusted global leader continued training and professional development.

associated with a variety of products and services. Founded in For more information please contact your local sales office
1907, the company known today as Mitsubishi Electric, quickly
rose to the forefront of the air conditioning industry -
a position we still enjoy today.
Mitsubishi Electric Training Options
Unsurpassed air conditioning from Mitsubishi Electric
Air conditioning is an ideal way of controlling the air quality inside any building, large or small. Mitsubishi Electric has four state-of-the-ar t training suites based
Not only does it cool in the summer months but air conditioning can also heat, replacing traditional at different locations around the countr y for your convenience.
heating systems. More and more people today are experiencing the benefits of comfortable working, Providing training for all levels of exper tise, our courses are
living and leisure environments made possible with air conditioning. As market leaders, we pride taught by experienced engineers, with a wealth of knowledge
ourselves in providing high performance, competitive systems with low running costs. and are all CPD accredited.
For bookings please telephone 01707 278797
Protecting the environment
Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as
energy and resource efficiency, minimising ecological impacts of our products and reducing
greenhouse gas emissions. We are the only manufacturer in the industry recognised by
Portfolio 21 as one of the top five companies in the world for our sustainable environmental
policy. All of our factories are also ISO 14001 registered, the international standard that
Systems marked with the ECA logo have an energy label of A or B, are registered on the
specifies a process for controlling and improving a company's environmental performance
Energy Technology List and hence qualify for 100% first year enhanced capital allowances
and with the advent of our Green Gateway Initiative, we strive to constantly promote (whole system cost and ‘reasonable’ cost of installation). For further information please
best practice. go to www.eca.gov.uk

The Forest Stewardship Council (FSC) is an international network promoting responsible


management of the world's forest. The paper this catalogue is printed on supports the
development of responsible forest management worldwide. The wood comes from FSC Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
certified, well managed forests, company controlled sources and/or recycled material. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Notes: Recommended fuse ratings given throughout this price list are based on British Standard (BS88).
Bigger, better and easier to use: the new
2008 Mitsubishi Electric Air Conditioning
Product Catalogue
This revised catalogue offers you more information than ever before. The first thing you’ll
notice is that the 2008 catalogue is bigger than before. That’s because the Mitsubishi
Electric air conditioning range contains many new models, plus a fully comprehensive
selection of control options to choose from.

In addition to increasing the range, we’ve also tried to help you find what you need more
quickly and efficiently. We hope you will find it an interesting and informative read.

If there is anything not covered in the catalogue and you want to know more, simply
contact your Mitsubishi Electric supplier who will be delighted to help you. Alternatively, you
can log onto our website at www.mitsubishielectric.co.uk/aircon for further information.

Contents
Page 13-52

Page 53-116

Page 117-197

Page 199-217

Page 219-254

Page 1
M Series / Mr Slim
Split-System Air Conditioning
Mitsubishi Electric
Split-Systems
M Series and Mr Slim
For the last couple of years Mitsubishi Electric’s M Series and Mr Slim range of split-systems
have gradually moved closer together, in terms of features and benefits, capacity and now most
importantly in terms of control. While both ranges maintain their individual brand identity, all
of our models have benefited from massive investment by Mitsubishi Electric, the overall result
being a vastly improved and more flexible collection of split-systems.

One of the most important features of the inverter range is the adoption of a new version of
A Control, allowing the standardisation of the M Series and Mr Slim ranges, as well as strengthening
the remote controller functionality. As a result of this it is now also possible to connect Mr Slim indoor
units to MXZ Multi-Split outdoor units, allowing for complete design flexibility. The Mr Slim Standard
Inverter models have further increased the range, offering a lower cost option, whilst still incorporating
Mitsubishi Electric’s energy saving inverter technology. Also new to the Split-Systems range are the new
high COP, MSZ-FD M Series models, our most efficient wall mounted units to date.

A Control is Mitsubishi Electric’s control mechanism for providing standard remote controller functions
alongside system diagnostics, fault code monitoring and the ability to interface with the MELANS
(Mitsubishi Electric Air Conditioning Network Solution) equipment such as the G50 Centralised
Controller, TG2000, Modbus, Trend, LonWorks® & BACnet® etc. A Control has now been further
improved by Mitsubishi Electric, providing increased flexibility alongside greater functionality.

Page 4
Energy Saving:
Reduced power consumption
increased efficiency

The entire R410A M Series and Mr Slim ranges are


available as an inverter option

Inverter technology saves energy for two main reasons:


1. The compressor varies its speed to match the cooling or heating load and therefore consumes only the power necessary
to match the exact requirement of the room.

2. When an inverter driven air conditioner is operating at partial load, the energy efficiency of the system is significantly
higher than at full load. In a typical application, partial load conditions prevail for more than 90% of operation time.
A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system.

The adoption of this technology as standard by Mitsubishi Electric, shows our commitment
to both increasing your savings as well as protecting the global environment.

Page 5
Energy Saving
Reduced power
consumption Technology
increased efficiency
Application of new technologies in Mitsubishi Electric inver ter systems significantly
enhance the generic benefits of inverter driven systems.

Reluctance DC Rotary Compressors


The centralised winding DC motor uses less copper wiring than a conventional version
and features a new high density, centralised winding method that raises motor winding
efficiency to 96%. Units incorporating this motor also benefit from a low starting current as
well as a stable set point.

Highly Efficient Scroll Compressors


The scroll compressor is equipped with a ‘Frame Compliance Mechanism’ that allows movement in
the axial direction of the frame supporting the moving scroll. This construction realises up to a 27%
improvement in compressor efficiency by reducing both leakage and friction losses.

DC Fan Motor Simple Par tial Switching Method


A high-efficiency DC motor drives the fan of the PAM Control
outdoor units. It offers up to 60% greater efficiency
Compared to the conventional active filter method, the simple
than an equivalent AC motor.
partial method PAM (Pulse Amplitude Modulation) control
found on the new models helps to reduce energy losses.
When combined with the Vector-Wave Eco Inver ter, PAM
control also allows for greater power and efficiency.

Normal Inverter vs. PAM


Supply Supply
Voltage Voltage
Current Current

Time Time

PAM adjusts the form of the current wave so that it is close to that
of the supply voltage wave. High harmonics are reduced and 98%
of the electricity is utilised.

Page 6
Total Energy
Conser vation
Vector-Wave Eco Inverter Power Receiver and Twin LEV Control
This technology uses a specially designed microprocessor Mitsubishi Electric has developed a power receiver and twin LEVs
to produce the most efficient waveform in response to (linear expansion valves) that optimise the performance of the
varying compressor motor rpm. By improving operating compressor. By ensuring optimum control in response to the
efficiency from low to high speeds, annual electricity operating waveform and outdoor temperature, this technology
costs are reduced. is tailored to the characteristics of the new refrigerant to
enhance operating efficiency.

Page 7
Re-use of existing
pipe work
Upgrading existing R22/R407c systems
to efficient inver ter models* 1

In general the upgrading of existing R22 systems to modern


efficient R410A systems has been a difficult or expensive option.
This is because the existing pipe work would either have to be replaced,
or cleaned with dedicated specialist equipment. These actions were
necessar y as the chlorine residue from R22 system pipe work
caused chemical reactions with the lubricating oils used in HFC
compressors, the result being poor performance and system failure.

Mitsubishi Electric’s
Replace Technology
The M Series Inverter*2 & Mr Slim Power commissioning the system is operated in
Inver ter ranges incorporate ‘Replace ‘Replace Mode’, this operation removing all
Technology’ to allow the upgrading of systems the chlorine contamination from the existing
using existing pipe work without the need to pipe work allowing trouble free operation.
apply any special cleaning machines. Sizes 25
to 71 utilise the Mitsubishi Electric patented
Hard Alkyl Benzene (HAB) oil, a unique oil Replacement filter (Sectional photo)
that is more tolerant of contamination. By
combining this oil with developments in oil Activated carbon
separator technology it is possible for this (absorbs chlorine and other chemicals)

model to use existing pipe work without any Refrigerant Refrigerant


special operations.

Sizes 100 to 250 continue to use the more


familiar Ester Oils that are sensitive to Inlet Filter Outlet
chemical contamination. To allow these models
to utilise existing pipe work a unique ‘Replace
Filter’ containing activated charcoal has been
included in the refrigerant circuit. During

*1 Assuming existing pipework is suitable for R410A operational pressures *2 Not available on the MXZ-8A140VA Multi-Split outdoor unit or Classic Inverter (MSZ-HC)

Page 8
Reduces installation
time & costs
Advantages
For tenants / owner
I Reduces installation time causing less disruption of business
I Saves on installation costs

For installer
I Installation time is reduced significantly
I It is not necessary to purchase new piping for R410A refrigerant
I Time-consuming pipe cleaning is not necessary when employing Replace Technology

Page 9
Split-System Product Range Overview
Outdoor Units
0.9kW Cooling Capacity
M Series M Series M Series M Series M Series M Series
Inverter Inverter Inverter Inverter Inverter Power Multi
(Multi-Split) Multi-Split Multi-Split

MUZ-GC25VA MUZ-GC35/FD25-35VA(H) MUZ-GB50/GA60-71VA MXZ-3A54VA MXZ-4A80VA MXZ-8A140VA


SUZ-KA25/35VA SUZ-KA50-71VA MXZ-4A71VA MXZ-5A100VA
MXZ-2A52VA

Indoor Units
22 25 35 50 60 71
Model / Size (2.2kW) (2.5kW) (3.5kW) (5.0kW) (6.0kW) (7.1kW)
Multi-Split only

MSZ-GA/GB/GC-VA

MSZ-FD-VA

PKA-RP-GAL/FAL(2)

MFZ-KA-VA

SEZ-KD-VA

PEAD-RP-EA(2)

PEA-RP-GA

SLZ-KA-VA

PLA-RP-BA(2)

PCA-RP-GA(2)

PCA-RP-HA

PSA-RP-GA

Page 10
44kW Cooling Capacity
Mr Slim Mr Slim Mr Slim Mr Slim Mr Slim Mr Slim Mr Slim
Standard Inverter Standard Inverter Power Inverter Power Inverter Power Inverter

PUH-P100YHA PUH-P125-140YHA PUHZ-P100VHA2 PUHZ-P125-140VHA2 PUHZ-RP35/50VHA3 PUHZ-RP60/71VHA3 PUHZ-RP100V/YHA3


PUHZ-P200/250YHA PUHZ-RP125/140V/YHA2
PUHZ-RP200/250YHA2

100 125 140 200 250 400 500


(10.0kW) (12.5kW) (14.0kW) (19.0kW) (22.0kW) (38.0kW) (44.0kW)

Page 11
The adaptable Split-System range
Designed to fit
anywhere
Available in a variety of options, our Split-System

range fits in wherever it’s needed. Indoor units

can be four way blow cassettes, ducted, wall,

floor or ceiling mounted. Up to eight indoor units

can then be connected to a single outdoor unit

providing the ideal air conditioning solution.

Simple technology
at its best
Systems marked with the ECA logo have an energy label of A or B, are registered on the
Energy Technology List and hence qualify for 100% first year enhanced capital allowances
(whole system cost and ‘reasonable’ cost of installation). For further information please
go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 12
M Series
Room Air Conditioning
The M Series range
Perfect for small to medium
sized applications

Designed to heat or cool small to medium sized applications, the M Series range provides a versatile,
yet affordable air conditioning solution. Quick to install and also one of the quietest units on the market
(as low as 20dBA*1 ), this newly designed, attractive range offers the perfect way to ensure a comfortable
environment with the minimum of disruption.

Surprisingly affordable, the efficiency of the


M Series range presents substantial savings in
Highly efficient
heating mode, when compared with more whilst ozone friendly too
conventional heating systems. Additional
features such as ‘Econo-Cool’ allow airflow to be The entire M Series range is now available
precisely directed towards users, allowing set using Inverter technology. By matching the
temperatures to be raised by 2ºC with no loss in compressor speed to the cooling or heating
comfort and a 20% gain in energy efficiency. load of the room, up to a 30% reduction
in power consumption can be achieved.
Flexible enough to suit a range of applications,
the M Series includes models that will run up to Increasingly aware of the importance of
eight indoor units per outdoor unit. With vastly protecting the environment, the M Series range
increased pipe length and height differences over uses the (ozone friendly) refrigerant with zero
its R407c predecessors, the M Series is extremely ODP (Ozone Depletion Potential) - R410A.
versatile, helping to make system application easier. Many models also make use of a new air
This diagram shows how a typical multi-split filtering system containing the compound
system could be installed into a medium sized Catechin, which helps to improve air quality and
office for example. prevent the spread of bacteria and viruses.

M Series offers the end user some of the highest


energy efficiency ratings available, alongside
greater application flexibility. Lower running
costs and increased comfor t for
consumers are vir tually guaranteed
and Mitsubishi Electric has made
M Series the natural choice for
today’s small to medium sized
application market.

*1 MSZ-FD25VA

Page 14
Designed to fit
anywhere
Clean, Comfor table
Environment
Catechin Filter
Catechin is a bioflavonoid that is found in green tea. Bioflavonoids are a group of chemical substances
present in many plants, that have both antiviral and antioxidant qualities. In addition to these benefits,
Catechin also offers excellent deodorising characteristics; which is why Mitsubishi Electric uses this
compound in its air conditioning filters to not only improve air quality, but to also prevent the spread
of bacteria and viruses within a room. The filter can be easily removed and when washed regularly,
deodorising effectiveness should last for more than 10 years. MSZ-G and MSZ-HC wall mounted
and MFZ floor mounted systems are supplied with or have the option of the Catechin filter.

“Anti-Allergy Enzyme Filter” mechanism

I Artificial enzyme catalyst on the filament catches the allergens.


I The artificial enzyme catalyst helps the chemical reaction with Oxygen
and severs the S-S bonds.*1
I Proteins with severed S-S bonds are no longer allergen proteins.

*1 Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.

Silent Operation
Technological improvements Only
20dBA
reducing operating sound levels
Unlike conventional models with a grilled air intake, wall mounted models feature a smoothly contoured,
flat panel finish with a top air intake that not only improves aesthetics, but also helps to reduce noise as
the heat exchanger area is fully covered. In fact, noise level during normal operation is only 20dBA for
the MSZ-FD25VA, making it one of the quietest indoor units on the market. This is as a result of the
multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a
smoother, quieter flow of air.

Alongside this, the wide diameter of the fan produces greater airflow at lower fan speeds and
the uneven pitch between each fan blade helps to eliminate unwanted noise.

Page 16
Operating Status
Monitoring
Monitor lamps located on the right of the indoor unit provide
at-a-glance recognition of the air conditioner operating status.
When the difference between the set temperature and room
temperature is more than 2°C, both monitor lamps will turn
on. If it is less than 2°C, only the upper lamp will light.

Quick Clean Design


The vane on the MSZ-GC22-35/GB50VA and MSZ-FD25/35VA
wall mounted models easily detaches, allowing access to the louvres.
These can then be opened outwards (without any special tools) for
quick cleaning of the heat exchanger, fan and air vents. Regular Quick Clean
cleaning will increase both operating efficiency and energy-savings.

Design can
reduce your
electricity bill by
approximately 30%

Electricity Electricity
bill increases bill increases
by 5%*1 by 25%*1

Heat Exchanger Fan Air Vent

*1 Electricity bill comparison of operation under a fixed


temperature with 8g of soil on the fan and also without.

Page 17
The New MSZ-FD Series
The new FD Series line-up is engineered for high
energy efficiency and low sound levels. The I-See Sensor,
Plasma-Duo filter system and other superb new functions
raise the comfort level to even greater heights.

High Energy Efficiency


With the latest inverter technology, energy efficiency is improved by about 20%.
Specifically, more than 5.0 is attained for both the COP and EER for a size 25.

Quiet Running
A larger line flow fan is included in
the FD model. This allows stable
capacity with fewer rotations,
reducing operating noise.

Powerful Heating Capacity


The VAH outdoor unit is engineered for use in cold regions and is equipped with a powerful compressor, enabling an improvement in
heating capacity. The heating power is raised by about 30% over the standard model and keeps the room comfortable even on cold days.

Field Test Result: Size 35. Sweden, 23rd January 2008

Page 18
The "I-See Sensor" automatically moves from side to side,
searching floor temperature over a wide area of 150°.
Conventional air conditioners control indoor temperature by using only the
temperature of the intake air at the top of the room. As a result, the floor
level temperature, which exerts such a crucial impact on the temperature
that people feel, tends to be overlooked. The I-See Sensor detects the
floor temperatures to ensure constant comfort in the living areas.

Cold air tends to sink to floor Warm air tends to rise up from
level, which is often the cause of the floor level, which often prevents
over cooling. The I-See Sensor that zone from warming up. The
tracks this floor level temperature I-See Sensor tracks this floor level
and adjusts the air outlet temperature and adjusts the air
temperature accordingly. outlet flow accordingly.

Besides a pre-filter, the MSZ-FD is also fitted with two plasma air-purifying
functions. These functions are engineered to change air dirt particles from
micron to nano-size in scale.

Plasma Electrode Unit


A plasma electrode unit is mounted inside the air
conditioner. Electro-discharge is used to generate
ozone & plasma. The collaboration between
ozone & plasma and two special filters creates
a dynamic plasma air cleaning function.

Plasma Air Purification


Plasma Deodorisation The “Anti-allergen electric enzyme filter” uses
The “Platinum catalyst deodorising filter” captures the power of the static electricity charged in
small foul-smelling substances in the air, then breaks the filter, as well as plasma generated in the
down the source of the odours with the power of plasma electrode unit to capture the bacteria,
the ozone generated in the plasma electrode unit pollen and other allergens in the air, which are
and the platinum catalyst contained in the filter. then neutralised by the enzyme in the filter.

The MSZ-FD is equipped with a “Mould Fighter” function designed to suppress the growth of
spores of mould. The ozone generated in the plasma electrode unit attacks the mould spores,
reducing mould growth by about 20%.
Mould Fighter mechanism
Step 1 Step 2
After cooling operation The heat exchanger
the Plasma Electrode is dried for about
unit fills the inside of the 40mins by the fan
indoor unit with ozone (O3). mode operation.

Page 19
MXZ Multi-Split Systems
The MXZ-8A140VA Power Multi Inver ter
Heat Pump Multi-Split Outdoor Unit

Ideal for apartments or


small commercial buildings

I 14kW Inverter Multi System, based on Mr Slim Power Inverter technology

I Ability to connect up to eight indoor units across the M Series and Mr Slim
product range within a capacity index of 18.5kW
I Total Pipe Length of 115m / Height Difference of 30m
I ‘A’ rated energy label - High COP (3.91) & EER (3.52)
I Single phase power supply
I Connection of indoor units is through either a 3-way (PAC-AK30BC)
or 5-way (PAC-AK50BC) branch box, either singularly or with two in combination
I Individual control of each indoor unit is now possible (ON/OFF and Setpoint)
I Low starting and running currents
I Connection to M-NET system via MAC-399IF-E interface (one per indoor unit needed)
I New Centralised Simple ON/OFF remote controller MAC-821SC-E available for use on all MXZ Multi-Split units.
Up to eight indoor units can be controlled from one remote controller (Interface MAC-397IF-E is needed, one per indoor unit)

Page 20
All Mitsubishi Electric MXZ Multi-Split
models have an energy label of ‘A’

Example of
Power Multi System
using eight indoor
Branch Box

units Branch Box

Outdoor Unit

Page 21
Excellent
Features
Available in wall and floor mounted, the M Series

range is quiet, economic to

run and easy to install. The outdoor units

can run up to eight indoor units, all

controlled with a simple remote controller.

Whatever your requirements

may be, Mitsubishi Electric

offers the perfect air conditioning

solution for any situation.

Simple technology
at its best
Systems marked with the ECA logo have an energy label of A or B, are registered on the
Energy Technology List and hence qualify for 100% first year enhanced capital allowances
(whole system cost and ‘reasonable’ cost of installation). For further information please
go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 22
Contents
24 MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System

26 MSH-GA-VB Heat Pump, Wall Mounted System

28 MSZ-GA/GB/GC-VA Inverter Heat Pump, Wall Mounted System

30 MSZ-FD-VA Inverter Heat Pump, Wall Mounted System

32 MFZ-KA-VA Inverter Heat Pump, Floor Mounted System

34 MXZ-A-VA Multi-Split Inverter Heat Pump

36 MXZ-8A140VA Power Multi Inverter Heat Pump

50 Outdoor Units

52 M Series Accessories / Optional Extras

Page 23
MSZ-HC-VA(B) Inverter Heat Pump
Classic Wall Mounted System
Mitsubishi Electric’s new range of high specification, flat panel wall mounted
models make use of inverter technology, whilst providing extremely good
value for money, costing approximately 20% less than the MSZ-G equivalent.

These units have extremely quiet sound levels, whilst also delivering
economical air conditioning, with improved COP/EER figures and in
many cases corresponding ‘A’ rated energy labels.

* Catechin filter is optional * Air cleaning filter is optional


Technical Information
MSZ-HC-VA(B) - INDOOR UNITS
MODEL REFERENCE MSZ-HC25VA MSZ-HC35VAB
CAPACITY (kW) Heating (nominal) 3.2 (0.9-4.4) 3.6 (0.9-4.8)
Cooling (nominal) 2.5 (0.9-3.0) 3.4 (1.0-3.7)
Heating (UK) 2.65 (0.75-3.65) 3.0 (0.75-4.0)
Cooling (UK) 2.5 (0.9-3.0) 3.35 (1.0-3.65)
SHF (nominal) 0.79 0.76
COP / EER (nominal) 3.64 / 3.25 3.62 / 3.01
ENERGY LABEL Heating/Cooling A /A A/B
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi 5.1-6.5-7.8-9.1 / 5.3-7.0-8.7-10.5 4.9-6.7-8.0-9.2 / 5.2-6.8-8.4-10.2
PIPE SIZE mm(in) Gas 9.52(3/8”) 9.52(3/8”)
Liquid 6.35(1/4”) 6.35(1/4”)
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi 26-32-38-43 / 26-32-38-43 26-32-38-43 / 26-32-38-43
DIMENSIONS (mm) Width 788 788
Depth 225 225
Height 295 295
WEIGHT (kg) 9 9
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single
RUNNING CURRENT (A) 0.22 0.22
FUSE RATING (BS88) - HRC (A) 6 6
INTERCONNECTING CABLE No. CORES 4 4

MUZ-HC-VA(B) - OUTDOOR UNITS


MODEL REFERENCE MUZ-HC25VA MUZ-HC35VAB
NOISE (dBA) Heating/Cooling 47 / 46 48 / 47
WEIGHT (kg) 25 25
DIMENSIONS (mm) Width 684 684
Depth 255 255
Height 540 540
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 0.88 / 0.77 0.995 / 1.13
Heating/Cooling (UK) 0.801 / 0.616 0.905 / 0.904
STARTING CURRENT (A) 4.2 5.3
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 4.2 / 3.7 [5.5] 4.8 / 5.3 [6.5]
FUSE RATING (BS88) - HRC (A) 16 16
MAINS CABLE No. CORES 3 3
MAX PIPE LENGTH (m) 10 10
MAX HEIGHT DIFFERENCE (m) 5 5
CHARGE R410A (kg) - 7m 0.73 0.75

Page 24
Dimensions

M Series Range 2008


INDOOR UNIT MSZ-HC25/35VA(B)

Upper View >

Front View > Side View >

MSZ-HC-VA(B) Inverter Heat Pump

Page 25
MSH-GA-VB Heat Pump
Classic Wall Mounted System
Mitsubishi Electric’s range of high specification, flat panel wall
mounted models make use of traditional fixed speed technology,
whilst providing extremely good value for money, costing
approximately 30% less than the inverter equivalent.

These units have extremely quiet sound levels, whilst also delivering
economical air conditioning. Ideal for use in any size room, both units
come equipped with a wide-angle airflow system, as well as an
automatic swing vane, allowing airflow to be extended to
every corner of a room.

* Air cleaning filter is optional


Technical Information
MSH-GA-VB - INDOOR UNITS
MODEL REFERENCE MSH-GA50VB MSH-GA60VB
CAPACITY (kW) Heating (nominal) 5.2 7.2
Cooling (nominal) 5.0 6.3
Heating (UK) 4.3 6.0
Cooling (UK) 4.95 6.25
SHF (nominal) 0.65 0.64
COP / EER (nominal) 3.23 / 2.81 2.90 / 2.61
ENERGY LABEL Heating/Cooling C/C D/D
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi 8.8-10.7-12.8 / 8.8-10.7-12.8 8.8-10.7-12.8 / 9.8-11.2-12.8
PIPE SIZE mm(in) Gas 12.7(1/2”) 15.88(5/8”)
Liquid 6.35(1/4”) 6.35(1/4”)
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi 34-38-42 / 34-38-42 34-40-45 / 37-41-45
DIMENSIONS (mm) Width 1100 1100
Depth 258 258
Height 325 325
WEIGHT (kg) 16 16
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single
RUNNING CURRENT (A) 0.30 0.30
FUSE RATING (BS88) - HRC (A) 6 6
INTERCONNECTING CABLE No. CORES 2 Core 12v 2 Core 12v

MUH-GA-VB - OUTDOOR UNITS


MODEL REFERENCE MUH-GA50VB MUH-GA60VB
NOISE (dBA) Heating/Cooling 52 / 52 53 / 53
WEIGHT (kg) 47 74
DIMENSIONS (mm) Width 850 840
Depth 290 330
Height 605 850
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.61 / 1.78 2.48 / 2.41
Heating/Cooling (UK) 1.465 / 1.424 2.257 / 1.928
STARTING CURRENT (A) 37 74
RUNNING CURRENT (A) [MAX] Heating/Cooling 7.23 / 7.93 [12.9] 10.70 / 10.39 [16.5]
FUSE RATING (BS88) - HRC (A) 16 25
MAINS CABLE No. CORES 3 3
MAX PIPE LENGTH (m) 25 25
MAX HEIGHT DIFFERENCE (m) 10 10
CHARGE R410A (kg) - 7m 1.80 2.35

Notes: MSH-GA50/60VB indoor units require a 240v, 50hz single phase supply and the outdoor units require the same, separate supply.
Between the indoor and outdoor unit is a 2 Core, low voltage interconnecting cable.

Page 26
Dimensions

M Series Range 2008


INDOOR UNIT MSH-GA50/60VB

Upper View >

Side View >


Front View >

MSH-GA-VB Heat Pump

Page 27
MSZ-GA/GB/GC-VA Inverter Heat Pump
Wall Mounted System
The MSZ series has been completely redesigned
and features the new Catechin filter system.

These models also offer industry leading noise


levels and have a distinctively styled front panel
that not only looks appealing but also helps
to make cleaning of the unit easier.

* Wide swing & long airflow mode available for MSZ-GA60/71VA * The anti-allergy enzyme filter is optional
* Quick clean design available for MSZ-GC22-35/GB50VA
Technical Information
MSZ-GA/GB/GC-VA - INDOOR UNITS
MODEL REFERENCE MSZ-GC22VA MSZ-GC25VA MSZ-GC35VA MSZ-GB50VA MSZ-GA60VA MSZ-GA71VA
CAPACITY (kW) Heating (nominal) 3.3 3.2 (0.9-4.5) 4.0 (0.9-5.0) 5.8 (0.9-7.8) 6.8 (0.9-8.1) 8.1 (0.9-9.6)
Cooling (nominal) 2.2 2.5 (0.9-3.0) 3.5 (1.0-3.9) 5.0 (0.9-5.8) 6.0 (0.9-6.7) 7.1 (0.9-8.3)
Heating (UK) 2.75 2.65 (0.75-3.75) 3.3 (0.75-4.15) 4.8 (0.75-6.5) 5.65 (0.75-6.75) 6.75 (0.75-8.0)
Cooling (UK) 2.2 2.5 (0.9-3.0) 3.45 (1.0-3.85) 4.95 (0.9-5.75) 5.95 (0.9-6.65) 7.05 (0.9-8.25)
SHF (nominal) - 0.79 0.76 0.69 0.79 0.71
COP / EER (nominal) - 3.83 / 3.76 3.79 / 3.26 3.41 / 3.03 3.51 / 3.11 3.31 / 2.93
ENERGY LABEL Heating/Cooling - A /A A /A B/B B/B C/C
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi 4.6-6.3-8.0-10.0 / 4.1-5.9-7.7-9.6 4.6-6.3-8.0-10.0 / 4.1-5.9-7.7-9.6 4.1-5.6-7.7-9.5 / 3.9-5.5-7.4-9.2 6.9-7.4-10.9 / 6.9-7.4-10.9 8.7-13.1-17.2 / 8.7-12.8-17.2 9.4-13.6-17.2 / 9.4-13.3-17.2
PIPE SIZE mm(in) Gas 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”)
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi 21-29-36-43 21-29-36-43 22-29-36-43 30-36-42-48 / 32-38-44-48 32-40-54 33-40-54
DIMENSIONS (mm) Width 788 788 788 780 1100 1100
Depth 234 234 234 210 258 258
Height 295 295 295 298 325 325
WEIGHT (kg) 9 9 9 9 16 16
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single Single
FUSE RATING (BS88) – HRC (A) 6 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4 4

MUZ-GA/GB/GC-VA - OUTDOOR UNITS


MODEL REFERENCE N/A Multi-Split Only MUZ-GC25VA MUZ-GC35VA MUZ-GB50VA MUZ-GA60VA MUZ-GA71VA
NOISE (dBA) Heating/Cooling - Lo-Hi - 47 / 46 48 / 47 53-55 / 51-52 53-55 / 51-53 53-55 / 51-53
WEIGHT (kg) - 26 31 53 53 58
DIMENSIONS (mm) Width - 684 800 840 840 840
Depth - 255 285 330 330 330
Height - 540 550 850 850 850
ELECTRICAL SUPPLY - 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) - 0.835 / 0.665 1.055 / 1.075 1.70 / 1.65 1.94 / 1.93 2.45 / 2.42
Heating/Cooling (UK) - 0.76 / 0.532 0.96 / 0.86 1.55 / 1.32 1.77 / 1.54 2.23 / 1.94
STARTING CURRENT (A) - 4.2 5.0 7.46 8.93 11.2
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling - 4.2 / 3.6 [5.8] 4.9 / 5.0 [6.5] 7.78 / 7.58 [16] 8.93 / 8.83 [16] 11.2 / 11.0 [16]
FUSE RATING (BS88) – HRC (A) - 16 16 25 25 25
MAINS CABLE No. CORES - 3 3 3 3 3
MAX PIPE LENGTH (m) - 20 20 30 30 30
MAX HEIGHT DIFFERENCE (m) - 12 12 15 15 15
CHARGE R410A (kg) - 7m - 0.75 0.85 1.5 1.8 2.0

Page 28
Dimensions

M Series Range 2008


INDOOR UNIT MSZ-GC22-35VA

Upper View >

Side View >

Front View >

INDOOR UNIT MSZ-GB50VA

Upper View >


Side View >

Front View >

INDOOR UNIT MSZ-GA60/71VA


MSZ-GA/GB/GC-VA Inverter Heat Pump
Upper View >

Side View >


Front View >

Page 29
MSZ-FD-VA Inverter Heat Pump
Wall Mounted System
The MSZ-FD series is our most energy efficient M Series
wall mounted unit to date. These high COP models feature
the new Plasma Duo filter system. These models also offer
industry leading noise levels and have a distinctively styled
front panel that not only looks appealing but also helps to
make cleaning of the unit easier.

Also incorporated is an ‘I-See Sensor’, providing even temperature


distribution and further reducing energy consumption.

Technical Information
MSZ-FD-VA - INDOOR UNITS
MODEL REFERENCE MSZ-FD25VA MSZ-FD35VA
CAPACITY (kW) Heating (nominal) 3.2 (1.5-6.3) 4.0 (1.3-7.7)
Cooling (nominal) 2.5 (1.1-3.5) 3.5 (0.8-4.0)
Heating (UK) 2.65 (1.25-5.25) 3.3 (1.1-6.4)
Cooling (UK) 2.5 (1.1-3.45) 3.45 (0.8-3.95)
SHF (nominal) 0.85 0.85
COP / EER (nominal) 5.25 / 5.15 4.71 / 4.19
ENERGY LABEL Heating/Cooling A /A A /A
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi 4.5-6.7-9.2-12.1 / 4.6-6.3-8.6-11.2 4.7-6.7-9.2-12.5 / 4.6-6.3-8.6-11.2
PIPE SIZE mm(in) Gas 9.52 (3/8”) 9.52 (3/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”)
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi 20-29-36-43 / 20-29-36-42 21-29-36-44 / 21-29-36-43
DIMENSIONS (mm) Width 798 798
Depth 257 257
Height 295 295
WEIGHT (kg) 12 12
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single
FUSE RATING (BS88) – HRC (A) 6 6
INTERCONNECTING CABLE No. CORES 4 4

MUZ-FD-VAH - OUTDOOR UNITS


MODEL REFERENCE MUZ-FD25VAH MUZ-FD35VAH
NOISE (dBA) Heating/Cooling 46 / 46 50 / 47
WEIGHT (kg) 36 36
DIMENSIONS (mm) Width 800 800
Depth 285 285
Height 550 550
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 0.61 / 0.485 0.85 / 0.835
Heating/Cooling (UK) 0.555 / 0.388 0.774 / 0.668
STARTING CURRENT (A) 2.9 3.9
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 2.9 / 2.4 [9.2] 3.9 / 3.8 [10.5]
FUSE RATING (BS88) – HRC (A) 16 16
MAINS CABLE No. CORES 3 3
MAX PIPE LENGTH (m) 20 20
MAX HEIGHT DIFFERENCE (m) 12 12
CHARGE R410A (kg) - 7m 1.15 1.15

Page 30
Dimensions

M Series Range 2008


INDOOR UNIT MSZ-FD25/35VA

Upper View >

Front View > Side View >

MSZ-FD-VA Inverter Heat Pump

Page 31
MFZ-KA-VA Inverter Heat Pump
Floor Mounted System
The MFZ-KA-VA series is extremely versatile and is
designed for wall attached installation at floor level.
The auto swing vane provides a more natural and
comfortable airflow throughout the room and
the lightweight, compact design makes
installation easy.

Technical Information
MFZ-KA-VA - INDOOR UNITS
MODEL REFERENCE MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA
CAPACITY (kW) Heating (nominal) 3.4 (0.9-5.1) 4.0 (0.9-6.2) 6.0 (0.9-7.9)
Cooling (nominal) 2.5 (0.9-3.4) 3.5 (0.9-3.9) 4.8 (0.9-5.4)
Heating (UK) 2.85 (0.75-4.25) 3.3 (0.75-5.15) 5.0 (0.75-6.55)
Cooling (UK) 2.5 (0.9-3.35) 3.45 (0.9-3.85) 4.75 (0.9-5.35)
SHF (nominal) 0.66 0.65 0.63
COP / EER (nominal) 4.07 / 4.31 3.64 / 3.21 3.23 / 3.10
ENERGY LABEL Heating/Cooling A /A A /A C/B
AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi 5.0-6.2-7.6-9.1 / 4.8-5.8-7.1-8.7 5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1 7.4-8.8-9.8-11.8 / 7.1-7.9-9.2-10.7
PIPE SIZE mm(in) Gas 9.52 (3/8”) 9.52 (3/8”) 12.7 (1/2”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”)
NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi 22-27-32-37 / 22-27-32-37 25-28-33-38 / 23-28-33-38 32-35-39-44 / 32-35-39-43
DIMENSIONS (mm) Width 700 700 700
Depth 200 200 200
Height 600 600 600
WEIGHT (kg) 14 14 14
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single
FUSE RATING (BS88) – HRC (A) 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4

SUZ-KA-VA - OUTDOOR UNITS


MODEL REFERENCE SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA
NOISE (dBA) Heating/Cooling 46 / 46 48 / 47 55 / 53
WEIGHT (kg) 33 37 53
DIMENSIONS (mm) Width 800 800 840
Depth 285 285 330
Height 550 550 850
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 0.835 / 0.58 1.10 / 1.09 1.86 / 1.55
Heating/Cooling (UK) 0.76 / 0.46 1.00 / 0.87 1.69 / 1.24
STARTING CURRENT (A) 3.8 4.8 8.3
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 4.0 / 2.8 [9.2] 5.0 / 5.0 [10.3] 8.5 / 7.0 [17.8]
FUSE RATING (BS88) - HRC (A) 16 16 25
MAINS CABLE No. CORES 3 3 3
MAX PIPE LENGTH (m) 20 20 30
MAX HEIGHT DIFFERENCE (m) 12 12 15
CHARGE R410A (kg) - 7m 0.9 1.05 1.6

Page 32
Dimensions

M Series Range 2008


INDOOR UNIT MFZ-KA25-50VA

Upper View >

Front View >

Side View > MFZ-KA-VA Inverter Heat Pump

Page 33
MXZ-A-VA Inverter Heat Pump (5.2 - 10.0kW)
Multi-Split Units
The multi-split system allows up to five M Series or Mr Slim wall mounted,
cassette, ducted, floor or ceiling mounted indoor unit heat-pumps of different
capacities to be operated from a single outdoor unit. This makes it an economic
answer in multi-room applications, whilst also offering space saving benefits.
I Up to five indoor units may be connected to a single outdoor unit
I Energy saving inverter controlled outdoor unit adjusts compressor performance
to economically match the demand for heating and cooling
I Units may be added within the capacity of the system as requirements change
I Single outdoor unit for minimal noise and space impact
I Capacities of indoor units may be mixed to suit individual rooms

Technical Information
MULTI-SPLIT - INDOOR UNITS
MODEL REFERENCE WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE CEILING SUSPENDED
MSZ-GC22/25/35VA
MXZ-2A52VA MSZ-FD25/35VA
MFZ-KA25/35VA SEZ-KD25/35VA SLZ-KA25/35VA

MSZ-GC22/25/35VA SLZ-KA25/35/50VA
SEZ-KD25/35/50VA
MXZ-3A54VA MSZ-GB50VA MFZ-KA25/35/50VA
PEAD-RP50EA PLA-RP50BA
PCA-RP50GA2
MSZ-FD25/35VA
MSZ-GC22/25/35VA
MSZ-GB50VA SEZ-KD25/35/50/60VA SLZ-KA25/35/50VA
MXZ-4A71VA MSZ-GA60VA
MFZ-KA25/35/50VA
PEAD-RP50EA PLA-RP50/60BA
PCA-RP50/60GA(2)
MSZ-FD25/35VA
MSZ-GC22/25/35VA
MSZ-GB50VA SEZ-KD25/35/50/60/71VA SLZ-KA25/35/50VA
MXZ-4A80VA MSZ-GA60/71VA
MFZ-KA25/35/50VA
PEAD-RP50EA PLA-RP50/60/71BA
PCA-RP50/60/71GA(2)
MSZ-FD25/35VA
MSZ-GC22/25/35VA
MSZ-GB50VA SEZ-KD25/35/50/60/71VA SLZ-KA25/35/50VA
MXZ-5A100VA MSZ-GA60/71VA
MFZ-KA25/35/50VA
PEAD-RP50EA PLA-RP50/60/71BA
PCA-RP50/60/71GA(2)
MSZ-FD25/35VA

MXZ-A-VA - OUTDOOR UNITS


MODEL REFERENCE MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA
NUMBER OF CONNECTABLE INDOOR UNITS 2 2-3 2-4 2-4 2-5
CAPACITY (kW) Heating (nominal) 6.4 (1.0-7.2) 6.8 (2.6-9.0) 8.6 (3.4-9.0) 9.4 (3.4-11.6) 12.0 (3.4-14.0)
Cooling (nominal) 5.2 (1.1-6.0) 5.4 (2.9-6.8) 7.1 (3.7-8.8) 8.0 (3.7-9.2) 10.0 (3.7-11.0)
Heating (UK) 5.3 (0.85-6.0) 5.65 (2.15-7.5) 7.15 (2.85-7.5) 7.8 (2.85-9.65) 9.95 (2.85-11.65)
Cooling (UK) 5.15 (1.1-5.95) 5.35 (2.9-6.75) 7.05 (3.65-8.75) 7.95 (3.65-9.15) 9.9 (3.65-10.9)
COP / EER (nominal) 3.75 / 3.46 4.67 / 4.17 4.41 / 3.68 4.87 / 3.65 4.23 / 3.41
ENERGY LABEL Heating/Cooling A /A A /A A /A A /A A /A
MAX AIRFLOW (m3/min) Heating/Cooling 31 / 31 41.2 / 42.1 46.5 / 42.1 43.8 / 42.2 59.3 / 56.6
NOISE (dBA) Heating/Cooling - Lo-Hi 48-50 / 45-49 47-48 / 44-46 48-50 / 45-48 46-48 / 44-46 46-54 / 45-51
DIMENSIONS (mm) Width 800 840 840 900 900
Depth 285 330 330 320 320
Height 550 710 710 900 900
WEIGHT (kg) 40 57 58 67 68
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
POWER INPUT (kW) Heating/Cooling (nominal) 1.705 / 1.505 1.455 / 1.295 1.95 / 1.93 1.93 / 2.19 2.835 / 2.935
Heating/Cooling (UK) 1.55 / 1.2 1.32 / 1.04 1.77 / 1.54 1.76 / 1.75 2.58 / 2.35
STARTING CURRENT (A) 7.64 6.39 8.56 9.62 12.88
RUNNING CURRENT (A) [MAX] Heating/Cooling 7.64 / 6.75 [10.2] 6.39 / 5.69 [16.4] 8.56 / 8.48 [16.4] 8.48 / 9.62 [17.4] 12.45 / 12.88 [19.4]
INTERCONNECTING CABLE No. CORES 4 Core 4 Core 4 Core 4 Core 4 Core
TOTAL PIPE LENGTH (m) 30 50 60 70 80
MAX PIPE LENGTH PER INDOOR UNIT (m) 20 25 25 25 25
MAX HEIGHT DIFFERENCE (m) 15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor)
CHARGE R410A (kg) - 40m (20m for MXZ-2A52VA) 1.3 2.7 2.7 3.5 4.0
FUSE RATING (BS88) – HRC (A) 16 25 25 25 25

Page 34
Dimensions

M Series Range 2008


OUTDOOR UNIT MXZ-2A52VA

Upper View > Front View > Side View >

OUTDOOR UNIT MXZ-3A54VA / MXZ-4A71VA

Upper View > Front View > Side View >

D connection for
MXZ-4A71VA

Multi-Split Inverter Heat Pump (5.2 -10.0kW)


OUTDOOR UNIT MXZ-4A80VA / MXZ-5A100VA

Upper View > Front View > Side View >

E connection for
MXZ-5A100VA
MXZ-A-VA

Page 35
MXZ-8A140VA Power Multi (14kW)
Inverter Heat Pump Multi-Split Unit
The Power Multi system allows up to eight M Series or Mr Slim cassette, ducted,
floor, ceiling or wall mounted indoor units of different capacities to be operated
from a single outdoor unit, making use of two types of branch box to achieve
this. This makes it an economic answer in multi-room applications and ideal for
apartments or small commercial buildings.

I 14kW Inverter Multi System, based on Mr Slim Power Inverter technology


I Total Pipe length of 115m / Height difference of 30m
I Individual control of each indoor unit is now possible (ON/OFF & Setpoint)
I Low starting and running currents
I Connection to M-NET system via MAC-399IF interface (one per indoor unit)
I New Centralised Simple ON/OFF remote controller MAC-821SC-E available to
control up to 8 indoor units (interface MAC-397IF is needed, one per indoor unit)

Technical Information
MULTI-SPLIT - INDOOR UNITS
MODEL REFERENCE WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE
MSZ-GC22/25/35VA
MSZ-GB50VA SEZ-KD25/35/50/60/71VA SLZ-KA25/35/50VA
MXZ-8A140VA MSZ-GA60/71VA
MFZ-KA25/35/50VA
PEAD-RP50/60/71EA PLA-RP35/50/60/71BA(2)
MSZ-FD25/35VA

MXZ-8A140VA - OUTDOOR UNIT PAC-AK30BC - BRANCH BOX


MODEL REFERENCE MXZ-8A140VA MODEL REFERENCE PAC-AK30BC

NUMBER OF CONNECTABLE INDOOR UNITS 2-8 NUMBER OF CONNECTABLE INDOOR UNITS 1-3
CAPACITY (kW) Heating (nominal) 16.0 POWER SUPPLY TO BRANCH BOX From Outdoor Unit
Cooling (nominal) 14.0 POWER SUPPLY TO INDOOR UNITS From Branch Box

Heating (UK) 13.3 PIPE SIZE mm(in) Main Outdoor Side - Gas 15.88(5/8”)

Cooling (UK) 13.9 PIPE SIZE mm(in) Main Outdoor Side - Liquid 9.52(3/8”)
MAX PIPE LENGTH - Outdoor Unit to Branch Box (m) 55
COP / EER (nominal) 4.10 / 3.69
TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m) 60
ENERGY LABEL Heating/Cooling A /A
MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m) 30
MAX AIRFLOW (m3/min) 100
MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m) 15
NOISE (dBA) Lo-Hi 52 / 50
DIMENSIONS (mm) Width 450
DIMENSIONS (mm) Width 950
Depth 280
Depth 330 (+30)
Height 198
Height 1350
WEIGHT (kg) 128 PAC-AK50BC - BRANCH BOX
ELECTRICAL SUPPLY 220-240v, 50Hz MODEL REFERENCE PAC-AK50BC
POWER INPUT (kW) Heating/Cooling (nominal) 3.90 / 3.79
NUMBER OF CONNECTABLE INDOOR UNITS 1-5
Heating/Cooling (UK) 3.55 / 3.03
POWER SUPPLY TO BRANCH BOX From Outdoor Unit
STARTING CURRENT (A) 14
POWER SUPPLY TO INDOOR UNITS From Branch Box
RUNNING CURRENT (A) [MAX] Heating/Cooling 16.33 / 15.86 [29.5] PIPE SIZE mm(in) Main Outdoor Side - Gas 15.88(5/8”)
INTERCONNECTING CABLE No. CORES 4 Core PIPE SIZE mm(in) Main Outdoor Side - Liquid 9.52(3/8”)
TOTAL PIPE LENGTH (m) 115 MAX PIPE LENGTH - Outdoor Unit to Branch Box (m) 55
MAX PIPE LENGTH PER INDOOR UNIT (m) 15 (from Branch Box) TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m) 60
FURTHEST PIPE LENGTH - Outdoor to Indoor (m) 70 MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m) 30
MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m) 30 (20 if Outdoor lower than Indoor) MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m) 15
MAX HEIGHT DIFFERENCE - Indoor to Indoor (m) 12 DIMENSIONS (mm) Width 450
CHARGE R410A (kg) - 40m 8.5 Depth 280
FUSE RATING (BS88) – HRC (A) 40 Height 198

Page 36
Dimensions

M Series Range 2008


OUTDOOR UNIT MXZ-8A140VA

Upper View >

Front View > Side View >

BRANCH BOX PAC-AK30BC

Front View > Side View > Upper View >

Power Multi Inverter Heat Pump (14kW)


BRANCH BOX PAC-AK50BC

Front View > Side View > Upper View >


MXZ-8A140VA

Page 37
Inverter Multi-Split
Systems

MXZ-3A54/4A71VA MXZ-4A80/5A100VA
Inverter Multi units Inverter Multi units

MXZ-2A52VA Inverter Multi unit 6


Outdoor Units
MXZ-8A140VA Power Multi unit

MSZ-GA/GB/GC-VA Series
30
Indoor Units
PEAD-RP-EA Series

MSZ-FD-VA Series PCA-RP-GA(2) Series

PLA-RP-BA(2) Series

MFZ-KA-VA Series SEZ-KD-VA Series

SLZ-KA-VA Series

Page 38
Multi-Split systems allow up to eight M Series or Mr Slim
cassette, ducted, floor, ceiling or wall mounted indoor
units of different capacities to be operated from
a single outdoor unit
Inverter Multi-Split System Combinations
MXZ-2A52VA MXZ-4A71VA
1 Outdoor Unit 2 Indoor Units 1 Outdoor Unit Up to 4 Indoor Units

Indoor unit Indoor unit


Cooling / Heating Capacity (kW) Cooling / Heating Capacity (kW)
combination combination

Unit A Unit B Unit C Unit A Unit B Unit C Unit D


1 ROOM 1 ROOM
22 2.20 / 3.30 22 2.20 / 3.30
25 2.50 / 3.60 25 2.50 / 3.60
35 3.50 / 4.00
35 3.50 / 4.00
50 5.00 / 7.20
2 ROOMS
22 + 22 60 6.00 / 7.90
2.20 / 3.05 2.20 / 3.05
22 + 25 2.20 / 2.90 2.50 / 3.30
22 + 35 1.93 / 2.43 3.07 / 3.87 2 ROOMS
25 + 25 2.50 / 3.15 2.50 / 3.15 22 + 22 2.20 / 3.30 2.20 / 3.30
25 + 35 2.13 / 2.63 2.97 / 3.67 22 + 25 2.20 / 3.23 2.50 / 3.67
35 + 35 2.60 / 3.20 2.60 / 3.20 22 + 35 2.20 / 2.82 3.50 / 4.48
22 + 50 2.08 / 2.63 4.72 / 5.97
22 + 60 1.82 / 2.31 4.98 / 6.29
25 + 25 2.50 / 3.60 2.50 / 3.60
MXZ-3A54VA 25 + 35 2.50 / 3.17 3.50 / 4.43
25 + 50 2.27 / 2.87 4.53 / 5.73
1 Outdoor Unit Up to 3 Indoor Units
25 + 60 2.00 / 2.53 4.80 / 6.07
Indoor unit 35 + 35 3.40 / 4.30 3.40 / 4.30
Cooling / Heating Capacity (kW)
combination 35 + 50 2.80 / 3.54 4.00 / 5.06
35 + 60 2.51 / 3.17 4.29 / 5.43
Unit A Unit B Unit C
50 + 50 3.40 / 4.30 3.40 / 4.30
1 ROOM
2.20 / 3.30 50 + 60 3.09 / 3.91 3.71 / 4.69
22
25 2.50 / 3.60 60 + 60 3.40 / 4.30 3.40 / 4.30
35 3.50 / 4.00
50 5.00 / 6.80 3 ROOMS
22 + 22 + 22 2.20 / 2.87 2.20 / 2.87 2.20 / 2.87
2 ROOMS 22 + 22 + 25 2.20 / 2.74 2.20 / 2.74 2.50 / 3.12
22 + 22 2.20 / 3.30 2.20 / 3.30
22 + 22 + 35 1.98 / 2.39 1.98 / 2.39 3.14 / 3.82
22 + 25 2.20 / 3.18 2.50 / 3.62
22 + 22 + 50 1.66 / 2.01 1.66 / 2.01 3.78 / 4.58
22 + 35 2.08 / 2.62 3.32 / 4.18
1.65 / 2.08 3.75 / 4.72 22 + 22 + 60 1.50 / 1.82 1.50 / 1.82 4.10 / 4.96
22 + 50
25 + 25 2.50 / 3.40 2.50 / 3.40 22 + 25 + 25 2.16 / 2.62 2.47 / 2.99 2.47 / 2.99
25 + 35 2.25 / 2.83 3.15 / 3.97 22 + 25 + 35 1.91 / 2.31 2.16 / 2.62 3.03 / 3.67
25 + 50 1.80 / 2.27 3.60 / 4.53 22 + 25 + 50 1.61 / 1.95 1.83 / 2.22 3.66 / 4.43
35 + 35 2.70 / 3.40 2.70 / 3.40 22 + 25 + 60 1.46 / 1.77 1.66 / 2.01 3.98 / 4.82
35 + 50 2.22 / 2.80 3.18 / 4.00 1.70 / 2.06 2.70 / 3.27 2.70 / 3.27
22 + 35 + 35
50 + 50 2.70 / 3.40 2.70 / 3.40
22 + 35 + 50 1.46 / 1.77 2.32 / 2.81 3.32 / 4.02
22 + 35 + 60 1.34 / 1.62 2.12 / 2.57 3.64 / 4.41
3 ROOMS
22 + 22 + 22 1.80 / 2.27 1.80 / 2.27 1.80 / 2.27 22 + 50 + 50 1.28 / 1.56 2.91 / 3.52 2.91 / 3.52
22 + 22 + 25 1.72 / 2.17 1.72 / 2.17 1.96 / 2.46 25 + 25 + 25 2.36 / 2.86 2.36 / 2.86 2.36 / 2.86
22 + 22 + 35 1.50 / 1.89 1.50 / 1.89 2.40 / 3.02 25 + 25 + 35 2.09 / 2.53 2.09 / 2.53 2.92 / 3.54
22 + 22 + 50 1.26 / 1.59 1.26 / 1.59 2.88 / 3.62 25 + 25 + 50 1.78 / 2.15 1.78 / 2.15 3.54 / 4.30
22 + 25 + 25 1.64 / 2.08 1.88 / 2.36 1.88 / 2.36 25 + 25 + 60 1.61 / 1.95 1.61 / 1.95 3.88 / 4.68
22 + 25 + 35 1.45 / 1.83 1.65 / 2.07 2.30 / 2.90 1.86 / 2.26 2.62 / 3.17 2.62 / 3.17
25 + 35 + 35
22 + 25 + 50 1.23 / 1.54 1.39 / 1.75 2.78 / 3.51
25 + 35 + 50 1.61 / 1.95 2.26 / 2.74 3.23 / 3.91
22 + 35 + 35 1.30 / 1.62 2.05 / 2.59 2.05 / 2.59
25 + 35 + 60 1.48 / 1.79 2.07 / 2.51 3.55 / 4.30
25 + 25 + 25 1.80 / 2.27 1.80 / 2.27 1.80 / 2.27
25 + 25 + 35 1.59 / 2.00 1.59 / 2.00 2.22 / 2.80 25 + 50 + 50 1.42 / 1.72 2.84 / 3.44 2.84 / 3.44
25 + 25 + 50 1.35 / 1.70 1.35 / 1.70 2.70 / 3.40 35 + 35 + 35 2.36 / 2.86 2.36 / 2.86 2.36 / 2.86
25 + 35 + 35 1.42 / 1.78 1.99 / 2.51 1.99 / 2.51 35 + 35 + 50 2.07 / 2.51 2.07 / 2.51 2.96 / 3.58

Page 40
Indoor unit Indoor unit
Cooling / Heating Capacity (kW) Cooling / Heating Capacity (kW)
combination combination

Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D


4 ROOMS 35 + 60 2.61 / 3.46 5.24 / 5.94
22 + 22 + 22 + 22 1.77 / 2.15 1.77 / 2.15 1.77 / 2.15 1.77 / 2.15 35 + 71 2.51 / 3.10 5.44 / 6.30
22 + 22 + 22 + 25 1.72 / 2.08 1.72 / 2.08 1.72 / 2.08 1.94 / 2.36 50 + 50 3.95 / 4.70 3.95 / 4.70
22 + 22 + 22 + 35 1.55 / 1.87 1.55 / 1.87 1.55 / 1.87 2.45 / 2.98 50 + 60 3.42 / 4.27 4.57 / 5.13
22 + 22 + 22 + 50 1.35 / 1.63 1.35 / 1.63 1.35 / 1.63 3.05 / 3.71
50 + 71 3.27 / 3.88 4.72 / 5.52
22 + 22 + 25 + 25 1.66 / 2.01 1.66 / 2.01 1.89 / 2.29 1.89 / 2.29
60 + 60 4.00 / 4.70 4.00 / 4.70
22 + 22 + 25 + 35 1.50 / 1.82 1.50 / 1.82 1.71 / 2.07 2.39 / 2.89
60 + 71 3.84 / 4.31 4.16 / 5.09
22 + 22 + 25 + 50 1.31 / 1.59 1.31 / 1.59 1.50 / 1.81 2.98 / 3.61
22 + 22 + 35 + 35 1.37 / 1.66 1.37 / 1.66 2.18 / 2.64 2.18 / 2.64
3 ROOMS
22 + 25 + 25 + 25 1.61 / 1.94 1.83 / 2.22 1.83 / 2.22 1.83 / 2.22
22 + 22 + 22 2.20 / 2.90 2.20 / 2.90 2.20 / 2.90
22 + 25 + 25 + 35 1.46 / 1.77 1.66 / 2.01 1.66 / 2.01 2.32 / 2.81
22 + 22 + 25 2.20 / 2.84 2.20 / 2.81 2.50 / 3.19
22 + 25 + 25 + 50 1.29 / 1.56 1.45 / 1.76 1.45 / 1.76 2.91 / 3.52
22 + 25 + 35 + 35 1.34 / 1.62 1.52 / 1.84 2.12 / 2.57 22 + 22 + 35 2.14 / 2.62 2.14 / 2.62 3.42 / 4.16
2.12 / 2.57
25 + 25 + 25 + 25 1.77 / 2.15 1.77 / 2.15 1.77 / 2.15 1.77 / 2.15 22 + 22 + 50 1.72 / 2.20 1.72 / 2.20 4.41 / 5.00

25 + 25 + 25 + 35 1.61 / 1.95 1.61 / 1.95 1.61 / 1.95 2.27 / 2.75 22 + 22 + 60 1.46 / 1.99 1.46 / 1.99 5.03 / 5.42

25 + 25 + 25 + 50 1.42 / 1.72 1.42 / 1.72 1.42 / 1.72 2.84 / 3.44 22 + 22 + 71 1.40 / 1.80 1.40 / 1.80 5.20 / 5.80
25 + 25 + 35 + 35 1.48 / 1.79 1.48 / 1.79 2.07 / 2.51 2.07 / 2.51 22 + 25 + 25 2.20 / 2.72 2.50 / 3.09 2.50 / 3.09

22 + 25 + 35 2.08 / 2.52 2.36 / 2.87 3.31 / 4.01

22 + 25 + 50 1.79 / 2.13 2.04 / 2.42 4.07 / 4.85

22 + 25 + 60 1.64 / 1.93 1.87 / 2.20 4.49 / 5.27

MXZ-4A80VA 22 + 25 + 71 1.49 / 1.75 1.69 / 1.99 4.82 / 5.66

22 + 35 + 35 1.87 / 2.25 2.99 / 3.58 2.99 / 3.58


1 Outdoor Unit Up to 4 Indoor Units
22 + 35 + 50 1.63 / 1.93 2.58 / 3.07 3.69 / 4.39

Indoor unit 22 + 35 + 60 1.50 / 1.77 2.40 / 2.81 4.1 / 4.82


Cooling / Heating Capacity (kW)
combination
22 + 35 + 71 1.38 / 1.62 2.18 / 2.57 4.44 / 5.21
Unit A Unit B Unit C Unit D 22 + 50 + 50 1.44 / 1.70 3.28 / 3.85 3.28 / 3.85
1 ROOM 22 + 50 + 60 1.33 / 1.57 3.03 / 3.56 3.64 / 4.27
22 2.20 / 3.30
22 + 50 + 71 1.23 / 1.45 2.80 / 3.29 3.97 / 4.67
25 2.50 / 3.60
25 + 25 + 25 2.50 / 3.00 2.50 / 3.00 2.50 / 3.00
35 3.50 / 4.00
50 5.00 / 7.20 25 + 25 + 35 2.28 / 2.76 2.28 / 2.76 3.19 / 3.87

60 6.00 / 7.90 25 + 25 + 50 1.98 / 2.35 1.98 / 2.35 3.94 / 4.70


71 7.10 / 8.60 25 + 25 + 60 1.82 / 2.14 1.82 / 2.14 4.36 / 5.13

25 + 25 + 71 1.65 / 1.94 1.65 / 1.94 4.70 / 5.52


2 ROOMS 25 + 35 + 35 2.07 / 2.48 2.89 / 3.46 2.89 / 3.46
22 + 22 2.20 / 3.30 2.20 / 3.30
25 + 35 + 50 1.82 / 2.14 2.54 / 2.99 3.64 / 4.27
22 + 25 2.20 / 3.23 2.50 / 3.67
25 + 35 + 60 1.67 / 1.96 2.33 / 2.74 4.00 / 4.70
22 + 35 2.20 / 2.82 3.50 / 4.48
22 + 50 2.20 / 2.72 5.00 / 6.20 25 + 35 + 71 1.53 / 1.79 2.14 / 2.51 4.33 / 5.09

22 + 60 1.75 / 2.52 6.00 / 6.88 25 + 50 + 50 1.60 / 1.88 3.20 / 3.76 3.20 / 3.76
22 + 71 1.66 / 2.22 6.19 / 7.18 25 + 50 + 60 1.48 / 1.74 2.96 / 3.48 3.56 / 4.18
25 + 25 2.50 / 3.60 2.50 / 3.60 35 + 35 + 35 2.65 / 3.13 2.65 / 3.13 2.65 / 3.13
25 + 35 2.50 / 3.17 3.50 / 4.43
35 + 35 + 50 2.33 / 2.74 2.33 / 2.74 3.34 / 3.92
25 + 50 2.50 / 3.00 5.00 / 6.00
35 + 35 + 60 2.15 / 2.53 2.15 / 2.53 3.70 / 4.34
25 + 60 2.11 / 2.76 5.64 / 6.64
35 + 35 + 71 1.99 / 2.33 1.99 / 2.33 4.02 / 4.74
25 + 71 2.01 / 2.42 5.84 / 6.98
35 + 35 3.50 / 4.00 3.50 / 4.00 35 + 50 + 50 2.08 / 2.44 2.96 / 3.48 2.96 / 3.48
35 + 50 3.10 / 3.87 4.65 / 5.53 35 + 50 + 60 1.93 / 2.27 2.76 / 3.24 3.31 / 3.89

Page 41
Indoor unit Indoor unit
Cooling / Heating Capacity (kW) Cooling / Heating Capacity (kW)
combination combination
Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D
4 ROOMS 2 ROOMS
22 + 22 + 22 + 22 1.95 / 2.35 1.95 / 2.35 1.95 / 2.35 1.95 / 2.35 22 + 22 2.20 / 3.30 2.20 / 3.30
22 + 22 + 22 + 25 1.90 / 2.27 1.90 / 2.27 1.90 / 2.27 2.15 / 2.59 22 + 25 2.20 / 3.23 2.50 / 3.67
22 + 22 + 22 + 35 1.73 / 2.05 1.73 / 2.05 1.73 / 2.05 2.76 / 3.25 22 + 35 2.20 / 2.82 3.50 / 4.48
22 + 22 + 22 + 50 1.52 / 1.78 1.52 / 1.78 1.52 / 1.78 3.44 / 4.06
22 + 50 2.20 / 2.72 5.00 / 6.18
22 + 22 + 22 + 60 1.40 / 1.64 1.40 / 1.64 1.40 / 1.64 3.81 / 4.48
22 + 60 2.08 / 2.52 5.67 / 6.88
22 + 22 + 22 + 71 1.28 / 1.51 1.28 / 1.51 1.28 / 1.51 4.16 / 4.87
22 + 71 1.86 / 2.22 5.99 / 7.18
22 + 22 + 25 + 25 1.87 / 2.20 1.87 / 2.20 2.13 / 2.50 2.13 / 2.50
25 + 25 2.50 / 3.60 2.50 / 3.60
22 + 22 + 25 + 35 1.68 / 1.99 1.68 / 1.99 1.91 / 2.26 1.91 / 3.16
22 + 22 + 25 + 50 1.48 / 1.74 1.48 / 1.74 1.68 / 1.97 3.36 / 3.95 25 + 35 2.50 / 3.17 3.50 / 4.43

22 + 22 + 25 + 60 1.36 / 1.60 1.36 / 1.60 1.55 / 1.83 3.73 / 4.37 25 + 50 2.50 / 3.00 5.00 / 6.00

22 + 22 + 25 + 71 1.26 / 1.48 1.26 / 1.48 1.43 / 1.68 4.05 / 4.76 25 + 60 2.28 / 2.94 5.47 / 7.06
22 + 22 + 35 + 35 1.54 / 1.81 1.54 / 1.81 2.46 / 2.89 2.46 / 2.89 25 + 71 2.04 / 2.60 5.81 / 7.40
22 + 22 + 35 + 50 1.36 / 1.60 1.36 / 1.60 2.18 / 2.55 3.10 / 3.65 35 + 35 3.50 / 4.00 3.50 / 4.00
22 + 22 + 35 + 60 1.12 / 1.49 1.12 / 1.49 1.92 / 2.37 3.84 / 4.05
35 + 50 3.19 / 4.12 4.56 / 5.88
22 + 22 + 50 + 50 1.22 / 1.44 1.22 / 1.44 2.78 / 3.26 2.78 / 3.26
35 + 60 2.89 / 3.68 4.96 / 6.32
22 + 25 + 25 + 25 1.78 / 2.14 2.04 / 2.42 2.04 / 2.42 2.04 / 2.42
35 + 71 2.62 / 3.30 5.33 / 6.70
22 + 25 + 25 + 35 1.63 / 1.93 1.86 / 2.20 1.86 / 2.20 2.60 / 3.07
50 + 50 3.95 / 5.00 3.95 / 5.00
22 + 25 + 25 + 50 1.44 / 1.70 1.64 / 1.93 1.64 / 1.93 3.28 / 3.85
22 + 25 + 25 + 60 1.33 / 1.57 1.52 / 1.78 1.52 / 1.78 3.64 / 4.27 50 + 60 3.64 / 4.55 4.36 / 5.45

22 + 25 + 35 + 35 1.51 / 1.77 1.71 / 2.01 2.39 / 2.81 2.39 / 2.81 50 + 71 3.43 / 4.13 4.87 / 5.87

22 + 25 + 35 + 50 1.33 / 1.57 1.52 / 1.78 2.12 / 2.49 3.03 / 3.56 60 + 60 4.15 / 5.00 4.15 / 5.00
22 + 25 + 35 + 60 1.24 / 1.46 1.41 / 1.65 1.97 / 2.32 3.38 / 3.97 60 + 71 3.89 / 4.58 4.61 / 5.42
22 + 35 + 35 + 35 1.40 / 1.63 2.20 / 2.59 2.20 / 2.59 2.20 / 2.59 71 + 71 4.40 / 5.00 4.40 / 5.00
22 + 35 + 35 + 50 1.24 / 1.45 1.97 / 2.32 1.97 / 2.32 2.82 / 3.31
25 + 25 + 25 + 25 1.98 / 2.35 1.98 / 2.35 1.98 / 2.35 1.98 / 2.35
3 ROOMS
25 + 25 + 25 + 35 1.82 / 2.14 1.82 / 2.14 1.82 / 2.14 2.54 / 2.98
22 + 22 + 22 2.20 / 2.90 2.20 / 2.90 2.20 / 2.90
25 + 25 + 25 + 50 1.60 / 1.88 1.60 / 1.88 1.60 / 1.88 3.20 / 3.76
22 + 22 + 25 2.20 / 2.80 2.20 / 2.81 2.50 / 3.19
25 + 25 + 25 + 60 1.48 / 1.74 1.48 / 1.74 1.48 / 1.74 3.56 / 4.18
25 + 25 + 35 + 35 1.67 / 1.96 1.67 / 1.96 2.33 / 2.74 2.33 / 2.74 22 + 22 + 35 2.14 / 2.78 2.14 / 2.78 3.42 / 4.44

25 + 25 + 35 + 50 1.48 / 1.74 1.48 / 1.74 2.08 / 2.44 2.96 / 3.48 22 + 22 + 50 1.84 / 2.57 1.84 / 2.57 4.17 / 5.86

25 + 35 + 35 + 35 1.55 / 1.81 2.15 / 2.53 2.15 / 2.53 2.15 / 2.53 22 + 22 + 60 1.68 / 2.33 1.68 / 2.33 4.59 / 6.35
35 + 35 + 35 + 35 2.00 / 2.35 2.00 / 2.35 2.00 / 2.35 2.00 / 2.35 22 + 22 + 71 1.53 / 2.10 1.53 / 2.10 4.94 / 6.80

22 + 25 + 25 2.20 / 2.72 2.50 / 3.09 2.50 / 3.09

22 + 25 + 35 2.08 / 2.68 2.36 / 3.05 3.31 / 4.27

MXZ-5A100VA 22 + 25 + 50

22 + 25 + 60
1.79 / 2.49

1.64 / 2.26
2.04 / 2.84

1.87 / 2.57
4.07 / 5.67

4.49 / 6.17
1 Outdoor Unit Up to 5 Indoor Units
22 + 25 + 71 1.49 / 2.05 1.69 / 2.33 4.82 / 6.62

Indoor unit 22 + 35 + 35 1.87 / 2.40 2.99 / 3.80 2.99 / 3.80


Cooling / Heating Capacity (kW)
combination
22 + 35 + 50 1.63 / 2.26 2.58 / 3.60 3.69 / 5.14
Unit A Unit B Unit C Unit D 22 + 35 + 60 1.50 / 2.07 2.40 / 3.29 4.1 / 5.64
1 ROOM 22 + 35 + 71 1.46 / 1.89 2.32 / 3.01 4.72 / 6.10
22 2.20 / 3.30
22 + 50 + 50 1.50 / 1.98 3.40 / 4.51 3.40 / 4.51
25 2.50 / 3.60
22 + 50 + 60 1.42 / 1.83 3.22 / 4.17 3.86 / 5.00
35 3.50 / 4.00
22 + 50 + 71 1.38 / 1.69 3.15 / 3.85 4.47 / 5.46
50 5.00 / 7.20
60 6.00 / 7.90 22 + 60 + 60 1.40 / 1.70 3.80 / 4.65 3.80 / 4.65

71 7.10 / 8.60 22 + 60 + 71 1.29 / 1.58 3.53 / 4.31 4.18 / 5.11

Page 42
Indoor unit Indoor unit
Cooling / Heating Capacity (kW) Cooling / Heating Capacity (kW)
combination combination

Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D


25 + 25 + 25 2.50 / 3.00 2.50 / 3.00 2.50 / 3.00 22 + 22 + 35 + 71 1.32 / 1.61 1.32 / 1.61 2.10 / 2.57 4.26 / 5.21

25 + 25 + 35 2.28 / 2.82 2.28 / 2.82 3.19 / 3.96 22 + 22 + 50 + 50 1.37 / 1.68 1.37 / 1.68 3.13 / 3.82 3.13 / 3.82

25 + 25 + 50 1.98 / 2.75 1.98 / 2.75 3.94 / 5.50 22 + 22 + 50 + 60 1.29 / 1.57 1.29 / 1.57 2.92 / 3.57 3.50 / 4.29

25 + 25 + 60 1.82 / 2.50 1.82 / 2.50 4.36 / 6.00 22 + 22 + 50 + 71 1.24 / 1.47 1.24 / 1.47 2.82 / 3.33 4.00 / 4.73
25 + 25 + 71 1.71 / 2.27 1.71/ 2.27 4.88 / 6.46 22 + 25 + 25 + 25 1.78 / 2.26 2.04 / 2.58 2.04 / 2.58 2.04 / 2.58
25 + 35 + 35 2.07 / 2.64 2.89 / 3.68 2.89 / 3.68
22 + 25 + 25 + 35 1.63 / 2.05 1.86 / 2.34 1.86 / 2.34 2.60 / 3.27
25 + 35 + 50 1.82 / 2.50 2.54 / 3.50 3.64 / 5.00
22 + 25 + 25 + 50 1.50 / 1.98 1.70 / 2.25 1.70 / 2.25 3.40 / 4.52
25 + 35 + 60 1.73 / 2.29 2.42 / 3.21 4.15 / 5.50
22 + 25 + 25 + 60 1.42 / 1.83 1.61 / 2.08 1.61 / 2.08 3.86 / 5.01
25 + 35 + 71 1.62 / 2.10 2.27 / 2.94 4.61 / 5.96
22 + 25 + 25 + 71 1.38 / 1.69 1.57 / 1.92 1.57 / 1.92 4.48 / 5.47
25 + 50 + 50 1.70 / 2.20 3.40 / 4.40 3.40 / 4.40
22 + 25 + 35 + 35 1.57 / 2.07 1.77 / 2.35 2.48 / 3.29 2.48 / 3.29
25 + 50 + 60 1.57 / 2.04 3.15 / 4.07 3.78 / 4.89
22 + 25 + 35 + 50 1.42 / 1.83 1.61 / 2.08 2.25 / 2.92 3.22 / 4.17
25 + 50 + 71 1.54 / 1.88 3.08 / 3.77 4.38 / 5.35
22 + 25 + 35 + 60 1.40 / 1.70 1.58 / 1.94 2.22 / 2.71 3.80 / 4.65
25 + 60 + 60 1.56 / 1.90 3.72 / 4.55 3.72 / 4.55
22 + 25 + 35 + 71 1.29 / 1.58 1.47 / 1.80 2.06 / 2.52 4.18 / 5.10
25 + 60 + 71 1.47 / 1.76 3.54 / 4.23 4.19 / 5.01
22 + 25 + 50 + 50 1.35 / 1.65 1.53 / 1.87 3.06 / 3.74 3.06 / 3.74
35 + 35 + 35 2.65 / 3.33 2.65 / 3.33 2.65 / 3.33
22 + 25 + 50 + 60 1.26 / 1.54 1.43 / 1.75 2.87 / 3.50 3.44 / 4.21
35 + 35 + 50 2.42 / 3.21 2.42 / 3.21 3.46 / 4.58
22 + 25 + 50 + 71 1.22 / 1.44 1.38 / 1.64 2.77 / 3.27 3.93 / 4.65
35 + 35 + 60 2.29 / 2.96 2.29 / 2.96 3.92 / 5.08

35 + 35 + 71 2.16 / 2.73 2.16 / 2.73 4.38 / 5.54 22 + 35 + 35 + 35 1.48 / 1.91 2.34 / 3.03 2.34 / 3.03 2.34 / 3.03

35 + 50 + 50 2.22 / 2.86 3.19 / 4.07 3.19 / 4.07 22 + 35 + 35 + 50 1.39 / 1.70 2.22 / 2.71 2.22 / 2.71 3.17 / 3.88

35 + 50 + 60 2.17 / 2.66 3.10 / 3.79 3.73 / 4.55 22 + 35 + 35 + 60 1.30 / 1.59 2.07 / 2.53 2.07 / 2.53 3.56 / 4.35

35 + 50 + 71 2.06 / 2.46 2.95 / 3.53 4.19 / 5.01 22 + 35 + 35 + 71 1.25 / 1.48 2.00 / 2.36 2.00 / 2.36 4.05 / 4.80

35 + 60 + 60 2.08 / 2.48 3.56 / 4.26 3.56 / 4.26 22 + 35 + 50 + 50 1.31 / 1.54 2.07 / 2.45 2.96 / 3.50 2.96 / 3.51

35 + 60 + 71 1.96 / 2.32 3.36 / 3.98 3.98 / 4.70 25 + 25 + 25 + 25 1.98 / 2.50 1.98 / 2.50 1.98 / 2.50 1.98 / 2.50

50 + 50 + 50 3.06 / 3.66 3.07 / 3.67 3.07 / 3.67 25 + 25 + 25 + 35 1.82 / 2.27 1.82 / 2.27 1.82 / 2.27 2.54 / 3.19
50 + 50 + 60 2.91 / 3.43 2.91 / 3.44 3.48 / 4.13 25 + 25 + 25 + 50 1.70 / 2.20 1.70 / 2.20 1.70 / 2.20 3.40 / 4.40
50 + 50 + 71 2.78 / 3.22 2.78 / 3.22 3.94 / 4.56
25 + 25 + 25 + 60 1.59 / 2.04 1.59 / 2.04 1.59 / 2.04 3.83 / 4.88

25 + 25 + 25 + 71 1.54 / 1.88 1.54 / 1.88 1.54 / 1.88 4.38 / 5.36


4 ROOMS
25 + 25 + 35 + 35 1.73 / 2.29 1.73 / 2.29 2.42 / 3.21 2.42 / 3.21
22 + 22 + 22 + 22 1.95 / 2.50 1.95 / 2.50 1.95 / 2.50 1.95 / 2.50
25 + 25 + 35 + 50 1.67 / 2.04 1.67 / 2.04 2.33 / 2.85 3.33 / 4.07
22 + 22 + 22 + 25 1.90 / 2.42 1.90 / 2.42 1.90 / 2.42 2.15 / 2.74
25 + 25 + 35 + 60 1.55 / 1.90 1.55 / 1.90 2.17 / 2.66 3.73 / 4.54
22 + 22 + 22 + 35 1.73 / 2.18 1.73 / 2.18 1.73 / 2.18 2.76 / 3.46
25 + 25 + 35 + 71 1.47 / 1.76 1.47 / 1.76 2.06 / 2.47 4.20 / 5.01
22 + 22 + 22 + 50 1.52 / 2.09 1.52 / 2.09 1.52 / 2.09 3.44 / 4.73
25 + 25 + 50 + 50 1.50 / 1.83 1.50 / 1.83 3.00 / 3.67 3.00 / 3.67
22 + 22 + 22 + 60 1.48 / 1.92 1.48 / 1.92 1.48 / 1.92 4.06 / 5.24
25 + 25 + 50 + 60 1.45 / 1.72 1.45 / 1.72 2.91 / 3.44 3.49 / 4.12
22 + 22 + 22 + 71 1.40 / 1.77 1.40 / 1.77 1.40 / 1.77 4.50 / 5.69
25 + 25 + 50 + 71 1.39 / 1.61 1.39 / 1.61 2.78 / 3.22 3.94 / 4.56
22 + 22 + 25 + 25 1.83 / 2.34 1.84 / 2.34 2.09 / 2.66 2.09 / 2.66
25 + 35 + 35 + 35 1.63 / 2.12 2.29 / 2.96 2.29 / 2.96 2.29 / 2.96
22 + 22 + 25 + 35 1.68 / 2.12 1.68 / 2.12 1.91 / 2.40 2.68 / 3.36
25 + 35 + 35 + 50 1.55 / 1.89 2.17 / 2.66 2.17 / 2.66 3.11 / 3.79
22 + 22 + 25 + 50 1.52 / 2.03 1.52 / 2.03 1.72 / 2.31 3.44 / 4.63

22 + 22 + 25 + 60 1.45 / 1.88 1.45 / 1.88 1.65 / 2.13 3.95 / 5.11 25 + 35 + 35 + 60 1.48 / 1.77 2.08 / 2.48 2.08 / 2.48 3.11 / 4.27

22 + 22 + 25 + 71 1.37 / 1.73 1.37 / 1.73 1.55 / 1.96 4.41 / 5.58 25 + 35 + 35 + 71 1.40 / 1.66 1.96 / 2.32 1.96 / 2.32 3.98 / 4.70

22 + 22 + 35 + 35 1.54 / 1.93 1.54 / 1.93 2.46 / 3.07 2.46 / 3.07 35 + 35 + 35 + 35 2.25 / 2.75 2.25 / 2.75 2.25 / 2.75 2.25 / 2.75

22 + 22 + 35 + 50 1.45 / 1.88 1.45 / 1.88 2.31 / 2.98 3.29 / 4.26 35 + 35 + 35 + 50 2.08 / 2.48 2.08 / 2.48 2.08 / 2.48 2.96 / 3.56

22 + 22 + 35 + 60 1.38 / 1.74 1.38 / 1.74 2.19 / 2.77 3.75 / 4.75 35 + 35 + 35 + 60 1.97 / 2.33 1.97 / 2.33 1.97 / 2.33 3.39 / 4.01

Page 43
Indoor unit
Cooling / Heating Capacity (kW)
combination

Unit A Unit B Unit C Unit D Unit E Unit F Unit G Unit H


5 ROOMS
22 + 22 + 22 + 22 + 22 2.00 / 2.40 2.00 / 2.40 2.00 / 2.40 2.00 / 2.40 2.00 / 2.40

22 + 22 + 22 + 22 + 25 1.95 / 2.34 1.95 / 2.34 1.95 / 2.34 1.95 / 2.34 2.20 / 2.65

22 + 22 + 22 + 22 + 35 1.79 / 2.15 1.79 / 2.15 1.79 / 2.15 1.79 / 2.15 2.84 / 3.40

22 + 22 + 22 + 22 + 50 1.59 / 1.91 1.59 / 1.91 1.59 / 1.91 1.59 / 1.91 3.64 / 4.36

22 + 22 + 22 + 22 + 60 1.49 / 1.78 1.49 / 1.78 1.49 / 1.78 1.49 / 1.78 4.04 / 4.88

22 + 22 + 22 + 22 + 71 1.38 / 1.66 1.38 / 1.66 1.38 / 1.66 1.38 / 1.66 4.48 / 5.36

22 + 22 + 22 + 25 + 25 1.90 / 2.28 1.90 / 2.28 1.90 / 2.28 2.15 / 2.58 2.15 / 2.58

22 + 22 + 22 + 25 + 35 1.75 / 2.10 1.75 / 2.10 1.75 / 2.10 1.97 / 2.38 2.78 / 3.32

22 + 22 + 22 + 25 + 50 1.56 / 1.87 1.56 / 1.87 1.56 / 1.87 1.77 / 2.13 3.55 / 4.26

22 + 22 + 22 + 25 + 60 1.46 / 1.75 1.46 / 1.75 1.46 / 1.75 1.66 / 1.99 3.96 / 4.76

22 + 22 + 22 + 25 + 71 1.36 / 1.63 1.36 / 1.63 1.36 / 1.63 1.54 / 1.85 4.38 / 5.26

22 + 22 + 22 + 35 + 35 1.62 / 1.94 1.62 / 1.94 1.62 / 1.94 2.57 / 3.09 2.57 / 3.09

22 + 22 + 22 + 35 + 50 1.46 / 1.75 1.46 / 1.75 1.46 / 1.75 2.32 / 2.78 3.30 / 3.97

22 + 22 + 22 + 35 + 60 1.37 / 1.64 1.37 / 1.64 1.37 / 1.64 2.17 / 2.61 3.72 / 4.47

22 + 22 + 22 + 35 + 71 1.28 / 1.53 1.28 / 1.53 1.28 / 1.53 2.03 / 2.44 4.13 / 4.95

22 + 22 + 25 + 25 + 25 1.85 / 2.22 1.85 / 2.22 2.10 / 2.52 2.10 / 2.52 2.10 / 2.52

22 + 22 + 25 + 25 + 35 1.71 / 2.04 1.71 / 2.04 1.94 / 2.33 1.94 / 2.33 2.70 / 3.26

22 + 22 + 25 + 25 + 50 1.53 / 1.83 1.53 / 1.83 1.74 / 2.08 1.74 / 2.08 3.46 / 4.18

22 + 22 + 25 + 25 + 60 1.43 / 1.71 1.43 / 1.71 1.62 / 1.95 1.62 / 1.95 3.90 / 4.68

22 + 22 + 25 + 25 + 71 1.33 / 1.60 1.33 / 1.60 1.52 / 1.82 1.52 / 1.82 4.30 / 5.16

22 + 22 + 25 + 35 + 35 1.58 / 1.90 1.58 / 1.90 1.80 / 2.16 2.52 / 3.02 2.52 / 3.02

22 + 22 + 25 + 35 + 50 1.43 / 1.71 1.43 / 1.71 1.62 / 1.95 2.27 / 2.73 3.25 / 3.90

22 + 22 + 35 + 35 + 35 1.47 / 1.77 1.48 / 1.77 2.35 / 2.82 2.35 / 2.82 2.35 / 2.82

22 + 25 + 25 + 25 + 25 1.80 / 2.16 2.05 / 2.46 2.05 / 2.46 2.05 / 2.46 2.05 / 2.46

22 + 25 + 25 + 25 + 35 1.67 / 2.00 1.89 / 2.27 1.89 / 2.27 1.89 / 2.27 2.66 / 3.19

22 + 25 + 25 + 25 + 50 1.50 / 1.80 1.70 / 2.04 1.70 / 2.04 1.70 / 2.04 3.40 / 4.08

22 + 25 + 25 + 25 + 60 1.40 / 1.68 1.59 / 1.91 1.59 / 1.91 1.59 / 1.91 3.83 / 4.59

22 + 25 + 25 + 25 + 71 1.30 / 1.57 1.49 / 1.79 1.49 / 1.79 1.49 / 1.79 4.23 / 5.07

22 + 25 + 25 + 35 + 35 1.56 / 1.86 1.76 / 2.11 1.76 / 2.11 2.46 / 2.96 2.46 / 2.96

22 + 25 + 25 + 35 + 50 1.40 / 1.68 1.59 / 1.91 1.59 / 1.91 2.23 / 2.68 3.19 / 3.82

22 + 25 + 25 + 35 + 60 1.31 / 1.58 1.50 / 1.80 1.50 / 1.80 2.10 / 2.51 3.59 / 4.31

22 + 25 + 35 + 35 + 35 1.46 / 1.75 1.64 / 1.97 2.30 / 2.76 2.30 / 2.76 2.30 / 2.76

25 + 25 + 25 + 25 + 25 2.00 / 2.40 2.00 / 2.40 2.00 / 2.40 2.00 / 2.40 2.00 / 2.40

25 + 25 + 25 + 25 + 35 1.85 / 2.22 1.85 / 2.22 1.85 / 2.22 1.85 / 2.22 2.60 / 3.12

25 + 25 + 25 + 25 + 50 1.67 / 2.00 1.67 / 2.00 1.67 / 2.00 1.67 / 2.00 3.32 / 4.00

25 + 25 + 25 + 25 + 60 1.56 / 1.88 1.56 / 1.88 1.56 / 1.88 1.56 / 1.88 3.76 / 4.50

25 + 25 + 25 + 25 + 71 1.46 / 1.75 1.46 / 1.75 1.46 / 1.75 1.46 / 1.75 4.16 / 4.98

25 + 25 + 25 + 35 + 35 1.72 / 2.07 1.72 / 2.07 1.72 / 2.07 2.42 / 2.90 2.42 / 2.90

25 + 25 + 35 + 35 + 35 1.61 / 1.94 1.61 / 1.94 2.26 / 2.71 2.26 / 2.71 2.26 / 2.71

25 + 25 + 35 + 35 + 50 1.47 / 1.76 1.47 / 1.76 2.06 / 2.47 2.06 / 2.47 2.94 / 3.54

Page 44
MXZ-8A140VA Indoor unit
Cooling / Heating Capacity (kW)
combination
1 Outdoor Unit Up to 8 Indoor Units
Unit A Unit B Unit C Unit D
Indoor unit 22 + 25 + 50 2.20 / 2.52 2.50 / 2.86 5.00 / 5.72
Cooling / Heating Capacity (kW)
combination
22 + 25 + 60 2.20 / 2.51 2.50 / 2.85 6.00 / 6.84
Unit A Unit B Unit C Unit D 22 + 25 + 71 2.20 / 2.52 2.50 / 2.86 7.10 / 8.12
1 ROOM 22 + 35 + 35 2.20 / 2.51 3.50 / 3.99 3.50 / 3.99
22 2.20 / 3.30
22 + 35 + 50 2.20 / 2.51 3.50 / 3.99 5.00 / 5.70
25 2.50 / 3.60
22 + 35 + 60 2.20 / 2.52 3.50 / 4.01 6.00 / 6.87
35 3.50 / 4.00
22 + 35 + 71 2.20 / 2.51 3.50 / 3.99 7.10 / 8.10
50 5.00 / 7.20
22 + 50 + 50 2.20 / 2.50 5.00 / 5.70 5.00 / 5.70
60 6.00 / 7.90
22 + 50 + 60 2.20 / 2.52 5.00 / 5.72 6.00 / 6.86
71 7.10 / 8.60
22 + 50 + 71 2.15 / 2.46 4.90 / 5.59 6.95 / 7.94

22 + 60 + 60 2.17 / 2.48 5.92 / 6.76 5.92 / 6.76

22 + 60 + 71 2.01 / 2.30 5.49 / 6.27 6.50 / 7.42


2 ROOMS
22 + 71 + 71 1.88 / 2.14 6.06 / 6.93 6.06 / 6.93
22 + 22 2.20 / 2.50 2.20 / 2.50
25 + 25 + 25 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86
22 + 25 2.20 / 2.53 2.50 / 2.87
25 + 25 + 35 2.50 / 2.85 2.50 / 2.85 3.50 / 3.99
22 + 35 2.20 / 2.51 3.50 / 3.99
25 + 25 + 50 2.50 / 2.85 2.50 / 2.85 5.00 / 5.70
22 + 50 2.20 / 2.51 5.00 / 5.69
25 + 25 + 60 2.50 / 2.86 2.50 / 2.86 6.00 / 6.87
22 + 60 2.20 / 2.52 6.00 / 6.88
25 + 25 + 71 2.50 / 2.85 2.50 / 2.85 7.10 / 8.10
22 + 71 2.20 / 2.51 7.10 / 8.09
25 + 35 + 35 2.50 / 2.86 3.50 / 4.02 3.50 / 4.02
25 + 25 2.50 / 2.85 2.50 / 2.85
25 + 35 + 50 2.50 / 2.86 3.50 / 4.01 5.00 / 5.73
25 + 35 2.50 / 2.88 3.50 / 4.02
25 + 35 + 60 2.50 / 2.85 3.50 / 4.00 6.00 / 6.85
25 + 50 2.50 / 2.87 5.00 / 5.73
25 + 35 + 71 2.50 / 2.86 3.50 / 4.01 7.10 / 8.13
25 + 60 2.50 / 2.85 6.00 / 6.85
25 + 50 + 50 2.50 / 2.86 5.00 / 5.72 5.00 / 5.72
25 + 71 2.50 / 2.86 7.10 / 8.14
25 + 50 + 60 2.50 / 2.85 5.00 / 5.70 6.00 / 6.84
35 + 35 3.50 / 4.00 3.50 / 4.00
25 + 50 + 71 2.40 / 2.74 4.79 / 5.48 6.81 / 7.78
35 + 50 3.50 / 3.99 5.00 / 5.71
25 + 60 + 60 2.41 / 2.76 5.79 / 6.62 5.79 / 6.62
35 + 60 3.50 / 4.02 6.00 / 6.88
25 + 60 + 71 2.24 / 2.56 5.38 / 6.15 6.37 / 7.28
35 + 71 3.50 / 4.00 7.10 / 8.10
25 + 71 + 71 2.10 / 2.40 5.95 / 6.80 5.95 / 6.80
50 + 50 5.00 / 5.70 5.00 / 5.70
35 + 35 + 35 3.50 / 4.00 3.50 / 4.00 3.50 / 4.00
50 + 60 5.00 / 5.73 6.00 / 6.87

5.00 / 5.70 7.10 / 8.10 35 + 35 + 50 3.50 / 4.00 3.50 / 4.00 5.00 / 5.70
50 + 71

60 + 60 6.00 / 6.85 6.00 / 6.85 35 + 35 + 60 3.50 / 4.01 3.50 / 4.01 6.00 / 6.88

60 + 71 6.00 / 6.87 7.10 / 8.13 35 + 35 + 71 3.48 / 3.97 3.48 / 3.97 7.05 / 8.06

71 + 71 7.00 / 8.00 7.00 / 8.00 35 + 50 + 50 3.50 / 3.99 5.00 / 5.70 5.00 / 5.70

35 + 50 + 60 3.38 / 3.86 4.83 / 5.52 5.79 / 6.62

35 + 50 + 71 3.14 / 3.59 4.49 / 5.13 6.37 / 7.28

3 ROOMS 35 + 60 + 60 3.16 / 3.61 5.42 / 6.19 5.42 / 6.19

22 + 22 + 22 2.20 / 2.50 2.20 / 2.50 2.20 / 2.50 35 + 60 + 71 2.95 / 3.37 5.06 / 5.78 5.99 / 6.84

22 + 22 + 25 2.20 / 2.52 2.20 / 2.52 2.50 / 2.86 35 + 71 + 71 2.77 / 3.16 5.62 / 6.42 5.62 / 6.42

22 + 22 + 35 2.20 / 2.51 2.20 / 2.51 3.50 / 3.98 50 + 50 + 50 4.67 / 5.33 4.67 / 5.33 4.67 / 5.33

22 + 22 + 50 2.20 / 2.50 2.20 / 2.50 5.00 / 5.69 50 + 50 + 60 4.38 / 5.00 4.38 / 5.00 5.25 / 6.00

22 + 22 + 60 2.20 / 2.52 2.20 / 2.52 6.00 / 6.86 50 + 50 + 71 4.09 / 4.68 4.09 / 4.68 5.81 / 6.64

22 + 22 + 71 2.20 / 2.51 2.20 / 2.51 7.10 / 8.09 50 + 60 + 60 4.12 / 4.70 4.94 / 5.65 4.94 / 5.65

22 + 25 + 25 2.20 / 2.50 2.50 / 2.85 2.50 / 2.85 50 + 60 + 71 3.87 / 4.42 4.64 / 5.30 5.49 / 6.28

22 + 25 + 35 2.20 / 2.52 2.50 / 2.87 3.50 / 4.01 60 + 60 + 60 4.67 / 5.33 4.67 / 5.33 4.67 / 5.33

Page 45
Indoor unit Indoor unit
Cooling / Heating Capacity (kW) Cooling / Heating Capacity (kW)
combination combination

Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D


4 ROOMS 22 + 35 + 35 + 60 2.03 / 2.32 3.22 / 3.68 3.22 / 3.68 5.53 / 6.32

22 + 22 + 22 + 22 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 22 + 35 + 35 + 71 1.89 / 2.16 3.01 / 3.44 3.01 / 3.44 6.09 / 6.96

22 + 22 + 22 + 25 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.50 / 2.86 22 + 35 + 50 + 50 1.96 / 2.23 3.12 / 3.57 4.46 / 5.10 4.46 / 5.10

22 + 22 + 22 + 35 2.20 / 2.50 2.20 / 2.50 2.20 / 2.50 3.50 / 3.99 22 + 35 + 50 + 60 1.84 / 2.11 2.93 / 3.35 4.19 / 4.79 5.03 / 5.75

22 + 22 + 22 + 50 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 5.00 / 5.73 22 + 35 + 50 + 71 1.73 / 1.98 2.75 / 3.15 3.93 / 4.49 5.58 / 6.38

22 + 22 + 22 + 60 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 6.00 / 6.86 22 + 35 + 60 + 60 1.73 / 1.99 2.77 / 3.16 4.75 / 5.42 4.75 / 5.42

22 + 22 + 22 + 71 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 7.10 / 8.14 22 + 50 + 50 + 50 1.79 / 2.05 4.07 / 4.65 4.07 / 4.65 4.07 / 4.65

22 + 22 + 25 + 25 22 + 50 + 50 + 60 1.69 / 1.93 3.85 / 4.40 3.85 / 4.40 4.61 / 5.27


2.20 / 2.50 2.20 / 2.50 2.50 / 2.85 2.50 / 2.85
25 + 25 + 25 + 25 2.50 / 2.85 2.50 / 2.85 2.50 / 2.85 2.50 / 2.85
22 + 22 + 25 + 35 2.20 / 2.52 2.20 / 2.52 2.50 / 2.86 3.50 / 4.00
25 + 25 + 25 + 35 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86 3.50 / 4.01
22 + 22 + 25 + 50 2.20 / 2.51 2.20 / 2.51 2.50 / 2.86 5.00 / 5.71
25 + 25 + 25 + 50 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86 5.00 / 5.72
22 + 22 + 25 + 60 2.20 / 2.51 2.20 / 2.51 2.50 / 2.85 6.00 / 6.83
25 + 25 + 25 + 60 2.50 / 2.85 2.50 / 2.85 2.50 / 2.85 6.00 / 6.84
22 + 22 + 25 + 71 2.20 / 2.51 2.20 / 2.51 2.50 / 2.86 7.10 / 8.11
25 + 25 + 25 + 71 2.40 / 2.74 2.40 / 2.74 2.40 / 2.74 6.80 / 7.78
22 + 22 + 35 + 35 2.20 / 2.51 2.20 / 2.51 3.50 / 3.99 3.50 / 3.99
25 + 25 + 35 + 35 2.50 / 2.85 2.50 / 2.85 3.50 / 4.00 3.50 / 4.00
22 + 22 + 35 + 50 2.20 / 2.51 2.20 / 2.51 3.50 / 3.99 5.00 / 5.69
25 + 25 + 35 + 50 2.50 / 2.85 2.50 / 2.85 3.50 / 3.99 5.00 / 5.70
22 + 22 + 35 + 60 2.20 / 2.52 2.20 / 2.52 3.50 / 4.00 6.00 / 6.86
25 + 25 + 35 + 60 2.41 / 2.76 2.41 / 2.76 3.38 / 3.86 5.79 / 6.62
22 + 22 + 35 + 71 2.05 / 2.35 2.05 / 2.35 3.27 / 3.73 6.63 / 7.57
25 + 25 + 35 + 71 2.24 / 2.56 2.24 / 2.56 3.14 / 3.59 6.37 / 7.28
22 + 22 + 50 + 50 2.14 / 2.44 2.14 / 2.44 4.86 / 5.56 4.86 / 5.56
25 + 25 + 50 + 50 2.33 / 2.67 2.33 / 2.67 4.67 / 5.33 4.67 / 5.33
22 + 22 + 50 + 60 2.00 / 2.29 2.00 / 2.29 4.55 / 5.19 5.45 / 6.23 25 + 25 + 50 + 60 2.19 / 2.50 2.19 / 2.50 4.38 / 5.00 5.24 / 6.00

22 + 22 + 50 + 71 1.87 / 2.13 1.87 / 2.13 4.24 / 4.85 6.02 / 6.88 25 + 25 + 50 + 71 2.05 / 2.34 2.05 / 2.34 4.09 / 4.68 5.81 / 6.64

22 + 22 + 60 + 60 1.88 / 2.15 1.88 / 2.15 5.12 / 5.85 5.12 / 5.85 25 + 25 + 60 + 60 2.06 / 2.35 2.06 / 2.35 4.94 / 5.65 4.94 / 5.65

22 + 22 + 60 + 71 1.76 / 2.01 1.76 / 2.01 4.80 / 5.49 5.68 / 6.49 25 + 25 + 60 + 71 1.93 / 2.21 1.93 / 2.21 4.64 / 5.30 5.49 / 6.28

22 + 25 + 25 + 25 2.20 / 2.52 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86 25 + 35 + 35 + 35 2.50 / 2.87 3.50 / 4.01 3.50 / 4.01 3.50 / 4.01

22 + 25 + 25 + 35 2.20 / 2.51 2.50 / 2.85 2.50 / 2.85 3.50 / 3.99 25 + 35 + 35 + 50 2.41 / 2.76 3.38 / 3.86 3.38 / 3.86 4.83 / 5.52

22 + 25 + 25 + 50 25 + 35 + 35 + 60 2.26 / 2.58 3.16 / 3.61 3.16 / 3.61 5.42 / 6.19


2.20 / 2.51 2.50 / 2.85 2.50 / 2.85 5.00 / 5.69
25 + 35 + 35 + 71 2.11 / 2.41 2.95 / 3.37 2.95 / 3.37 5.99 / 6.84
22 + 25 + 25 + 60 2.20 / 2.52 2.50 / 2.86 2.50 / 2.86 6.00 / 6.86
25 + 35 + 50 + 50 2.18 / 2.50 3.06 / 3.50 4.38 / 5.00 4.38 / 5.00
22 + 25 + 25 + 71 2.15 / 2.46 2.45 / 2.80 2.45 / 2.80 6.95 / 7.94
25 + 35 + 50 + 60 2.06 / 2.35 2.88 / 3.29 4.12 / 4.71 4.94 / 5.65
22 + 25 + 35 + 35 2.20 / 2.52 2.50 / 2.86 3.50 / 4.01 3.50 / 4.01
25 + 35 + 50 + 71 1.93 / 2.21 2.71 / 3.09 3.87 / 4.42 5.49 / 6.28
22 + 25 + 35 + 50 2.20 / 2.52 2.50 / 2.86 3.50 / 4.00 5.00 / 5.72
25 + 35 + 60 + 60 1.94 / 2.22 2.72 / 3.11 4.67 / 5.33 4.67 / 5.33
22 + 25 + 35 + 60 2.17 / 2.48 2.46 / 2.82 3.45 / 3.94 5.92 / 6.76
25 + 50 + 50 + 50 2.00 / 2.29 4.00 / 4.57 4.00 / 4.57 4.00 / 4.57
22 + 25 + 35 + 71 2.01 / 2.30 2.29 / 2.61 3.20 / 3.66 6.50 / 7.42
25 + 50 + 50 + 60 1.89 / 2.16 3.78 / 4.32 3.78 / 4.32 4.54 / 5.19
22 + 25 + 50 + 50 2.10 / 2.39 2.38 / 2.72 4.76 / 5.44 4.76 / 5.44
35 + 35 + 35 + 35 3.50 / 4.00 3.50 / 4.00 3.50 / 4.00 3.50 / 4.00
22 + 25 + 50 + 60 1.96 / 2.24 2.23 / 2.55 4.46 / 5.10 5.35 / 6.11
35 + 35 + 35 + 50 3.16 / 3.61 3.16 / 3.61 3.16 / 3.61 4.52 / 5.16
22 + 25 + 50 + 71 1.83 / 2.10 2.08 / 2.38 4.17 / 4.76 5.92 / 6.76
35 + 35 + 35 + 60 2.97 / 3.39 2.97 / 3.39 2.97 / 3.39 5.09 / 5.82
22 + 25 + 60 + 60 1.84 / 2.10 2.10 / 2.40 5.03 / 5.75 5.03 / 5.75 35 + 35 + 35 + 71 2.78 / 3.18 2.78 / 3.18 2.78 / 3.18 5.65 / 6.45

22 + 25 + 60 + 71 1.73 / 1.98 1.97 / 2.25 4.72 / 5.39 5.58 / 6.38 35 + 35 + 50 + 50 2.88 / 3.29 2.88 / 3.29 4.12 / 4.71 4.12 / 4.71

22 + 35 + 35 + 35 2.20 / 2.50 3.50 / 4.00 3.50 / 4.00 3.50 / 4.00 35 + 35 + 50 + 60 2.72 / 3.11 2.72 / 3.11 3.89 / 4.44 4.67 / 5.33

22 + 35 + 35 + 50 2.17 / 2.48 3.45 / 3.94 3.45 / 3.94 4.93 / 5.63 35 + 50 + 50 + 50 2.65 / 3.03 3.78 / 4.32 3.78 / 4.32 3.78 / 4.32

Page 46
Indoor unit
Cooling / Heating Capacity (kW)
combination

Unit A Unit B Unit C Unit D Unit E Unit F Unit G Unit H


5 ROOMS
22 + 22 + 22 + 22 + 22 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52
22 + 22 + 22 + 22 + 25 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.50 / 2.85
22 + 22 + 22 + 22 + 35 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 3.50 / 4.01
22 + 22 + 22 + 22 + 50 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 5.00 / 5.72
22 + 22 + 22 + 22 + 60 2.08 / 2.38 2.08 / 2.38 2.08 / 2.38 2.08 / 2.38 5.68 / 6.48
22 + 22 + 22 + 22 + 71 1.94 / 2.21 1.94 / 2.21 1.94 / 2.21 1.94 / 2.21 6.24 / 7.14
22 + 22 + 22 + 25 + 25 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.50 / 2.87 2.50 / 2.87
22 + 22 + 22 + 25 + 35 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.50 / 2.86 3.50 / 4.00
22 + 22 + 22 + 25 + 50 2.18 / 2.50 2.18 / 2.50 2.18 / 2.50 2.48 / 2.84 4.96 / 5.66
22 + 22 + 22 + 25 + 60 2.04 / 2.33 2.04 / 2.33 2.04 / 2.33 2.32 / 2.65 5.56 / 6.36
22 + 22 + 22 + 25 + 71 1.90 / 2.17 1.90 / 2.17 1.90 / 2.17 2.16 / 2.47 6.14 / 7.01
22 + 22 + 22 + 35 + 35 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 3.50 / 3.98 3.50 / 3.98
22 + 22 + 22 + 35 + 50 2.04 / 2.33 2.04 / 2.33 2.04 / 2.33 3.25 / 3.71 4.63 / 5.30
22 + 22 + 22 + 35 + 60 1.91 / 2.19 1.91 / 2.19 1.91 / 2.19 3.04 / 3.48 5.22 / 5.95
22 + 22 + 22 + 35 + 71 1.79 / 2.05 1.79 / 2.05 1.79 / 2.05 2.85 / 3.26 5.78 / 6.59
22 + 22 + 22 + 50 + 50 1.86 / 2.12 1.86 / 2.12 1.86 / 2.12 4.21 / 4.82 4.21 / 4.82
22 + 22 + 22 + 50 + 60 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 3.98 / 4.55 4.77 / 5.45
22 + 22 + 25 + 25 + 25 2.20 / 2.51 2.20 / 2.51 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86
22 + 22 + 25 + 25 + 35 2.20 / 2.51 2.20 / 2.51 2.50 / 2.85 2.50 / 2.85 3.50 / 3.98
22 + 22 + 25 + 25 + 50 2.14 / 2.44 2.14 / 2.44 2.43 / 2.78 2.43 / 2.78 4.86 / 5.56
22 + 22 + 25 + 25 + 60 2.00 / 2.29 2.00 / 2.29 2.27 / 2.60 2.27 / 2.60 5.45 / 6.22
22 + 22 + 25 + 25 + 71 1.87 / 2.13 1.87 / 2.13 2.12 / 2.42 2.12 / 2.42 6.02 / 6.88
22 + 22 + 25 + 35 + 35 2.20 / 2.52 2.20 / 2.52 2.50 / 2.86 3.50 / 4.00 3.50 / 4.00
22 + 22 + 25 + 35 + 50 2.00 / 2.29 2.00 / 2.29 2.27 / 2.60 3.18 / 3.64 4.55 / 5.18
22 + 22 + 25 + 35 + 60 1.88 / 2.15 1.88 / 2.15 2.13 / 2.44 2.99 / 3.41 5.12 / 5.85
22 + 22 + 25 + 35 + 71 1.76 / 2.01 1.76 / 2.01 2.00 / 2.29 2.80 / 3.20 5.68 / 6.49
22 + 22 + 25 + 50 + 50 1.82 / 2.08 1.82 / 2.08 2.07 / 2.37 4.14 / 4.73 4.14 / 4.73
22 + 22 + 25 + 50 + 60 1.72 / 1.97 1.72 / 1.97 1.96 / 2.23 3.91 / 4.47 4.69 / 5.36
22 + 22 + 35 + 35 + 35 2.06 / 2.36 2.06 / 2.36 3.29 / 3.76 3.29 / 3.76 3.29 / 3.76
22 + 22 + 35 + 35 + 50 1.88 / 2.15 1.88 / 2.15 2.99 / 3.41 2.99 / 3.41 4.26 / 4.88
22 + 22 + 35 + 35 + 60 1.77 / 2.02 1.77 / 2.02 2.82 / 3.22 2.82 / 3.22 4.82 / 5.52
22 + 22 + 35 + 35 + 71 1.66 / 1.90 1.66 / 1.90 2.65 / 3.03 2.65 / 3.03 5.37 / 6.14
22 + 22 + 35 + 50 + 50 1.72 / 1.97 1.72 / 1.97 2.74 / 3.12 3.91 / 4.47 3.91 / 4.47
22 + 25 + 25 + 25 + 25 2.20 / 2.50 2.50 / 2.85 2.50 / 2.85 2.50 / 2.85 2.50 / 2.85
22 + 25 + 25 + 25 + 35 2.20 / 2.52 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86 3.50 / 4.00
22 + 25 + 25 + 25 + 50 2.10 / 2.39 2.38 / 2.72 2.38 / 2.72 2.38 / 2.72 4.76 / 5.44
22 + 25 + 25 + 25 + 60 1.96 / 2.24 2.23 / 2.55 2.23 / 2.55 2.23 / 2.55 5.35 / 6.11
22 + 25 + 25 + 25 + 71 1.83 / 2.10 2.08 / 2.38 2.08 / 2.38 2.08 / 2.38 5.92 / 6.76
22 + 25 + 25 + 35 + 35 2.17 / 2.48 2.46 / 2.82 2.46 / 2.82 3.45 / 3.94 3.45 / 3.94
22 + 25 + 25 + 35 + 50 1.96 / 2.24 2.23 / 2.55 2.23 / 2.55 3.12 / 3.57 4.46 / 5.09
22 + 25 + 25 + 35 + 60 1.84 / 2.11 2.10 / 2.40 2.10 / 2.40 2.93 / 3.35 5.03 / 5.74
22 + 25 + 25 + 35 + 71 1.73 / 1.98 1.97 / 2.25 1.97 / 2.25 2.75 / 3.15 5.58 / 6.37
22 + 25 + 25 + 50 + 50 1.79 / 2.04 2.03 / 2.33 2.03 / 2.33 4.07 / 4.65 4.07 / 4.65
22 + 25 + 25 + 50 + 60 1.69 / 1.93 1.92 / 2.20 1.92 / 2.20 3.85 / 4.40 4.62 / 5.27
22 + 25 + 35 + 35 + 35 2.03 / 2.32 2.30 / 2.63 3.22 / 3.68 3.22 / 3.68 3.22 / 3.68
22 + 25 + 35 + 35 + 50 1.84 / 2.11 2.10 / 2.40 2.93 / 3.35 2.93 / 3.35 4.19 / 4.79
22 + 25 + 35 + 35 + 60 1.74 / 1.99 1.98 / 2.26 2.77 / 3.16 2.77 / 3.16 4.74 / 5.42
22 + 25 + 35 + 50 + 50 1.69 / 1.92 1.92 / 2.20 2.69 / 3.08 3.85 / 4.40 3.85 / 4.40
22 + 35 + 35 + 35 + 35 1.90 / 2.16 3.02 / 3.46 3.02 / 3.46 3.02 / 3.46 3.02 / 3.46
22 + 35 + 35 + 35 + 50 1.74 / 1.99 2.77 / 3.16 2.77 / 3.16 2.77 / 3.16 3.95 / 4.52

Page 47
Indoor unit
Cooling / Heating Capacity (kW)
combination

Unit A Unit B Unit C Unit D Unit E Unit F Unit G Unit H


25 + 25 + 25 + 25 + 25 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86 2.50 / 2.86
25 + 25 + 25 + 25 + 35 2.50 / 2.85 2.50 / 2.85 2.50 / 2.85 2.50 / 2.85 3.50 / 3.99
25 + 25 + 25 + 25 + 50 2.33 / 2.67 2.33 / 2.67 2.33 / 2.67 2.33 / 2.67 4.67 / 5.32
25 + 25 + 25 + 25 + 60 2.19 / 2.50 2.19 / 2.50 2.19 / 2.50 2.19 / 2.50 5.24 / 6.00
25 + 25 + 25 + 25 + 71 2.05 / 2.34 2.05 / 2.34 2.05 / 2.34 2.05 / 2.34 5.80 / 6.64
25 + 25 + 25 + 35 + 35 2.41 / 2.76 2.41 / 2.76 2.41 / 2.76 3.38 / 3.86 3.38 / 3.86
25 + 25 + 25 + 35 + 50 2.19 / 2.50 2.19 / 2.50 2.19 / 2.50 3.06 / 3.50 4.37 / 5.00
25 + 25 + 25 + 35 + 60 2.06 / 2.35 2.06 / 2.35 2.06 / 2.35 2.88 / 3.29 4.94 / 5.65
25 + 25 + 25 + 35 + 71 1.93 / 2.21 1.93 / 2.21 1.93 / 2.21 2.71 / 3.09 5.49 / 6.28
25 + 25 + 25 + 50 + 50 2.00 / 2.29 2.00 / 2.29 2.00 / 2.29 4.00 / 4.56 4.00 / 4.56
25 + 25 + 25 + 50 + 60 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 3.78 / 4.32 4.54 / 5.19
25 + 25 + 35 + 35 + 35 2.26 / 2.58 2.26 / 2.58 3.16 / 3.61 3.16 / 3.61 3.16 / 3.61
25 + 25 + 35 + 35 + 50 2.06 / 2.35 2.06 / 2.35 2.88 / 3.29 2.88 / 3.29 4.12 / 4.71
25 + 25 + 35 + 35 + 60 1.94 / 2.22 1.94 / 2.22 2.72 / 3.11 2.72 / 3.11 4.67 / 5.33
25 + 25 + 35 + 50 + 50 1.89 / 2.16 1.89 / 2.16 2.65 / 3.03 3.78 / 4.32 3.78 / 4.32
25 + 35 + 35 + 35 + 35 2.12 / 2.42 2.97 / 3.39 2.97 / 3.39 2.97 / 3.39 2.97 / 3.39
25 + 35 + 35 + 35 + 50 1.94 / 2.22 2.72 / 3.11 2.72 / 3.11 2.72 / 3.11 3.89 / 4.44
35 + 35 + 35 + 35 + 35 2.80 / 3.20 2.80 / 3.20 2.80 / 3.20 2.80 / 3.20 2.80 / 3.20

6 ROOMS
22 + 22 + 22 + 22 + 22 + 22 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51
22 + 22 + 22 + 22 + 22 + 25 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.50 / 2.85
22 + 22 + 22 + 22 + 22 + 35 2.12 / 2.43 2.12 / 2.43 2.12 / 2.43 2.12 / 2.43 2.12 / 2.43 3.38 / 3.85
22 + 22 + 22 + 22 + 22 + 50 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 4.38 / 5.00
22 + 22 + 22 + 22 + 22 + 60 1.81 / 2.07 1.81 / 2.07 1.81 / 2.07 1.81 / 2.07 1.81 / 2.07 4.94 / 5.65
22 + 22 + 22 + 22 + 22 + 71 1.70 / 1.94 1.70 / 1.94 1.70 / 1.94 1.70 / 1.94 1.70 / 1.94 5.49 / 6.28
22 + 22 + 22 + 22 + 25 + 25 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.20 / 2.52 2.50 / 2.86 2.50 / 2.86
22 + 22 + 22 + 22 + 25 + 35 2.08 / 2.38 2.08 / 2.38 2.08 / 2.38 2.08 / 2.38 2.36 / 2.70 3.31 / 3.78
22 + 22 + 22 + 22 + 25 + 50 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 2.15 / 2.45 4.29 / 4.91
22 + 22 + 22 + 22 + 25 + 60 1.78 / 2.03 1.78 / 2.03 1.78 / 2.03 1.78 / 2.03 2.02 / 2.31 4.86 / 5.55
22 + 22 + 22 + 22 + 25 + 71 1.67 / 1.91 1.67 / 1.91 1.67 / 1.91 1.67 / 1.91 1.90 / 2.17 5.40 / 6.17
22 + 22 + 22 + 22 + 35 + 35 1.95 / 2.23 1.95 / 2.23 1.95 / 2.23 1.95 / 2.23 3.10 / 3.54 3.10 / 3.54
22 + 22 + 22 + 22 + 35 + 50 1.78 / 2.03 1.78 / 2.03 1.78 / 2.03 1.78 / 2.03 2.83 / 3.24 4.05 / 4.62
22 + 22 + 22 + 22 + 35 + 60 1.68 / 1.92 1.68 / 1.92 1.68 / 1.92 1.68 / 1.92 2.68 / 3.06 4.59 / 5.25
22 + 22 + 22 + 25 + 25 + 25 2.18 / 2.50 2.18 / 2.50 2.18 / 2.50 2.48 / 2.83 2.48 / 2.83 2.48 / 2.83
22 + 22 + 22 + 25 + 25 + 35 2.04 / 2.33 2.04 / 2.33 2.04 / 2.33 2.32 / 2.65 2.32 / 2.65 3.24 / 3.71
22 + 22 + 22 + 25 + 25 + 50 1.86 / 2.12 1.86 / 2.12 1.86 / 2.12 2.10 / 2.41 2.10 / 2.41 4.22 / 4.82
22 + 22 + 22 + 25 + 25 + 60 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.99 / 2.27 1.99 / 2.27 4.77 / 5.45
22 + 22 + 22 + 25 + 35 + 35 1.91 / 2.19 1.91 / 2.19 1.91 / 2.19 2.17 / 2.47 3.04 / 3.48 3.04 / 3.48
22 + 22 + 22 + 25 + 35 + 50 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.99 / 2.27 2.78 / 3.18 3.98 / 4.55
22 + 22 + 22 + 35 + 35 + 35 1.80 / 2.06 1.80 / 2.06 1.80 / 2.06 2.86 / 3.27 2.86 / 3.27 2.86 / 3.27
22 + 22 + 25 + 25 + 25 + 25 2.14 / 2.44 2.14 / 2.44 2.43 / 2.78 2.43 / 2.78 2.43 / 2.78 2.43 / 2.78
22 + 22 + 25 + 25 + 25 + 35 2.00 / 2.28 2.00 / 2.28 2.27 / 2.60 2.27 / 2.60 2.27 / 2.60 3.18 / 3.64
22 + 22 + 25 + 25 + 25 + 50 1.82 / 2.08 1.82 / 2.08 2.07 / 2.37 2.07 / 2.37 2.07 / 2.37 4.14 / 4.73
22 + 22 + 25 + 25 + 25 + 60 1.72 / 1.97 1.72 / 1.97 1.96 / 2.23 1.96 / 2.23 1.96 / 2.23 4.68 / 5.36
22 + 22 + 25 + 25 + 35 + 35 1.88 / 2.15 1.88 / 2.15 2.13 / 2.44 2.13 / 2.44 2.99 / 3.41 2.99 / 3.41
22 + 22 + 25 + 25 + 35 + 50 1.72 / 1.97 1.72 / 1.97 1.96 / 2.23 1.96 / 2.23 2.74 / 3.13 3.90 / 4.47
22 + 22 + 25 + 35 + 35 + 35 1.70 / 2.02 1.70 / 2.02 2.00 / 2.30 2.82 / 3.22 2.82 / 3.22 2.82 / 3.22
22 + 22 + 35 + 35 + 35 + 35 1.67 / 1.91 1.67 / 1.91 2.66 / 3.04 2.66 / 3.04 2.66 / 3.04 2.66 / 3.04
22 + 25 + 25 + 25 + 25 + 25 2.10 / 2.39 2.38 / 2.72 2.38 / 2.72 2.38 / 2.72 2.38 / 2.72 2.38 / 2.72

Page 48
Indoor unit
Cooling / Heating Capacity (kW)
combination

Unit A Unit B Unit C Unit D Unit E Unit F Unit G Unit H


22 + 25 + 25 + 25 + 25 + 35 1.96 / 2.24 2.23 / 2.55 2.23 / 2.55 2.23 / 2.55 2.23 / 2.55 3.12 / 3.56
22 + 25 + 25 + 25 + 25 + 50 1.79 / 2.04 2.03 / 2.33 2.03 / 2.33 2.03 / 2.33 2.03 / 2.33 4.07 / 4.64
22 + 25 + 25 + 25 + 25 + 60 1.69 / 1.93 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 4.62 / 5.27
22 + 25 + 25 + 25 + 35 + 35 1.84 / 2.10 2.10 / 2.40 2.10 / 2.40 2.10 / 2.40 2.93 / 3.35 2.93 / 3.35
22 + 25 + 25 + 25 + 35 + 50 1.69 / 1.93 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 2.69 / 3.08 3.85 / 4.39
22 + 25 + 25 + 35 + 35 + 35 1.73 / 1.99 1.98 / 2.26 1.98 / 2.26 2.77 / 3.16 2.77 / 3.16 2.77 / 3.16
25 + 25 + 25 + 25 + 25 + 25 2.33 / 2.66 2.33 / 2.66 2.33 / 2.66 2.33 / 2.66 2.33 / 2.66 2.33 / 2.66
25 + 25 + 25 + 25 + 25 + 35 2.19 / 2.50 2.19 / 2.50 2.19 / 2.50 2.19 / 2.50 2.19 / 2.50 3.05 / 3.50
25 + 25 + 25 + 25 + 25 + 50 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 4.00 / 4.57
25 + 25 + 25 + 25 + 25 + 60 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 4.54 / 5.19
25 + 25 + 25 + 25 + 35 + 35 2.06 / 2.35 2.06 / 2.35 2.06 / 2.35 2.06 / 2.35 2.88 / 3.29 2.88 / 3.29
25 + 25 + 25 + 25 + 35 + 50 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 2.65 / 3.03 3.78 / 4.32
25 + 25 + 25 + 35 + 35 + 35 1.94 / 2.22 1.94 / 2.22 1.94 / 2.22 2.72 / 3.11 2.72 / 3.11 2.72 / 3.11

7 ROOMS
22 + 22 + 22 + 22 + 22 + 22 + 22 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28
22 + 22 + 22 + 22 + 22 + 22 + 25 1.96 / 2.24 1.96 / 2.24 1.96 / 2.24 1.96 / 2.24 1.96 / 2.24 1.96 / 2.24 2.23 / 2.55
22 + 22 + 22 + 22 + 22 + 22 + 35 1.84 / 2.11 1.84 / 2.11 1.84 / 2.11 1.84 / 2.11 1.84 / 2.11 1.84 / 2.11 2.93 / 3.34
22 + 22 + 22 + 22 + 22 + 22 + 50 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 3.85 / 4.40
22 + 22 + 22 + 22 + 22 + 25 + 25 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 2.19 / 2.50 2.19 / 2.50
22 + 22 + 22 + 22 + 22 + 25 + 35 1.81 / 2.07 1.81 / 2.07 1.81 / 2.07 1.81 / 2.07 1.81 / 2.07 2.06 / 2.35 2.88 / 3.29
22 + 22 + 22 + 22 + 22 + 25 + 50 1.66 / 1.90 1.66 / 1.90 1.66 / 1.90 1.66 / 1.90 1.66 / 1.90 1.89 / 2.16 3.78 / 4.32
22 + 22 + 22 + 22 + 22 + 35 + 35 1.71 / 1.96 1.71 / 1.96 1.71 / 1.96 1.71 / 1.96 1.71 / 1.96 2.72 / 3.10 2.72 / 3.10
22 + 22 + 22 + 22 + 25 + 25 + 25 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 2.14 / 2.45 2.14 / 2.45 2.14 / 2.45
22 + 22 + 22 + 22 + 25 + 25 + 35 1.78 / 2.03 1.78 / 2.03 1.78 / 2.03 1.78 / 2.03 2.02 / 2.31 2.02 / 2.31 2.83 / 3.24
22 + 22 + 22 + 22 + 25 + 35 + 35 1.68 / 1.92 1.68 / 1.92 1.68 / 1.92 1.68 / 1.92 1.91 / 2.19 2.68 / 3.06 2.68 / 3.06
22 + 22 + 22 + 25 + 25 + 25 + 25 1.85 / 2.12 1.85 / 2.12 1.85 / 2.12 2.11 / 2.41 2.11 / 2.41 2.11 / 2.41 2.11 / 2.41
22 + 22 + 22 + 25 + 25 + 25 + 35 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.99 / 2.27 1.99 / 2.27 1.99 / 2.27 2.78 / 3.18
22 + 22 + 25 + 25 + 25 + 25 + 25 1.82 / 2.07 1.82 / 2.07 2.07 / 2.37 2.07 / 2.37 2.07 / 2.37 2.07 / 2.37 2.07 / 2.37
22 + 22 + 25 + 25 + 25 + 25 + 35 1.71 / 1.97 1.71 / 1.97 1.96 / 2.23 1.96 / 2.23 1.96 / 2.23 1.96 / 2.23 2.74 / 3.13
22 + 25 + 25 + 25 + 25 + 25 + 25 1.79 / 2.05 2.03 / 2.32 2.03 / 2.32 2.03 / 2.32 2.03 / 2.32 2.03 / 2.32 2.03 / 2.32
22 + 25 + 25 + 25 + 25 + 25 + 35 1.69 / 1.93 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 1.92 / 2.20 2.69 / 3.07
25 + 25 + 25 + 25 + 25 + 25 + 25 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28
25 + 25 + 25 + 25 + 25 + 25 + 35 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 2.65 / 3.03

8 ROOMS
22 + 22 + 22 + 22 + 22 + 22 + 22 + 22 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00 1.75 / 2.00
22 + 22 + 22 + 22 + 22 + 22 + 22 + 25 1.72 / 1.96 1.72 / 1.96 1.72 / 1.96 1.72 / 1.96 1.72 / 1.96 1.72 / 1.96 1.72 / 1.96 1.96 / 2.23
22 + 22 + 22 + 22 + 22 + 22 + 25 + 25 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 1.69 / 1.93 1.92 / 2.20 1.92 / 2.20
22 + 22 + 22 + 22 + 22 + 25 + 25 + 25 1.66 / 1.90 1.66 / 1.90 1.66 / 1.90 1.66 / 1.90 1.66 / 1.90 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16

Page 49
Outdoor Units
MUZ-GC35VA / MUZ-FD25/35VAH / SUZ-KA25/35VA

Upper View >

Side View >


Front View >

MUZ-HC25/35VA(B) / MUZ-GC25VA

Upper View >

Side View >


Front View >

Dimensions

Page 50
M Series Range 2008
Dimensions

MUH-GA50VB

Upper View >

Side View >


Front View >

MUH-GA60VB / MUZ-GB50VA / MUZ-GA60/71VA / SUZ-KA50VA

Upper View >

Front View > Side View >


Outdoor Unit Dimensions

Page 51
M Series Range 2008
Accessories / Optional Extras
M Series

Air Cleaning Filter MAC-1700FT - for MSH-GA50/60VB (10 pack)

Catechin Filter MAC-3003CF - for MSZ-HC25/35VA(B) (10 pack)

Anti-Allergy Enzyme Filter MAC-408FT-E - for MSZ-GC22-35VA (10 pack)


MAC-415FT-E - for MSZ-GB50VA (10 pack)
MAC-2300FT - for MSZ-GA60-71VA (10 pack)

Wired Remote controller PAR-21MAA - for MSZ-GC22-35VA, MSZ-GB50VA, MSZ-GA60/71VA, MSZ-FD25/35VA & MFZ-KA25-50VA
MAC-821SC-E - Centralised Simple ON/OFF Remote Controller for MXZ Multi-Splits

Interfaces MAC-399IF - for connection to M-NET system


MAC-397IF - for Contact Terminal, PAR-21MAA Wired Remote Controller and MAC-821SC-E
Centralised ON/OFF Remote Controller

Air Outlet Guide PAC-SG59SG-E - for MXZ-8A140VA


Accessories / Optional Extras

Page 52
Mr Slim
Packaged Split-System Air Conditioning
The Mr Slim range
Compact and versatile, the
Suitable to heat or cool a huge variety of applications, the Mr Slim range is one
of Britain’s best selling air conditioning split-systems. Combine the efficiency
with the complete versatility that this range has to offer and the possibilities
are virtually infinite.

The 2008 Mr Slim range has been updated with new features, as well as the already
impressive efficiency levels being improved. New to the range are the 19 & 22kW outdoor
models, available in both Power Inverter and Standard Inverter options. The smaller
outdoor models have also undergone improvements, in line with Mitsubishi Electrics
forward looking approach.

New indoor units include the SEZ-KD ducted models and four new large capacity ducted
models (PEA-RP-GA) available in up to 44kW cooling capacity. A new range of 4-way
blow cassettes (PLA-RP-BA2) are now available with improved COP's and EER's, further
increasing Mitsubsihi Electrics energy efficient portfolio. Finally a range of Heat Pump
Air Curtains have been developed with Thermoscreens, for use with our Power Inverter
models, an ideal application for a retail establishment.

Mr Slim units are more than just physically compact and discreet. They’re also amongst
the quietest operating units available, which means that apart from enjoying a comfortable,
controllable environment, users hardly know Mr Slim is there at all.

Page 54
options are endless

Easy to fit An installers favourite, the excellent design of the Mr Slim range ensures quick and
simple installation with the minimum of disruption. With extensive pipe runs of up
to120m, this versatile range makes it easier to select a layout to install the unit.

wherever you need


Power Inverter
The Mr Slim Power Inverter range is now stronger than ever.
The technological developments applied to this new range of equipment
offer the end user some of the highest energy efficiency ratings available,
alongside greater application flexibility.

This range is available in single and 3-phase options, the latter having running
currents that are more than half that of the single phase option, offering a
clear benefit to business premises that already have 3-phase supply installed.
All models have low starting currents of 5 amps.

The issue of using existing R22/R407c pipe work has been resolved
using Mitsubishi Electric’s unique ‘Replace Technology’, offering the opportunity to upgrade
older, less efficient systems with the minimum of cost and installation disruption.

Improved COP / EER Ratings - COP and EER ratings have increased across
the board with many models within our range now having energy labels of ‘A’ in both
heating and cooling.

Reducing Power Consumption by 70% - The Mr Slim Power Inverter can


reduce power consumption by up to 70% compared to a previously installed non-inverter
model* 1, making the energy cost savings associated with this range truly remarkable. A high
power function also delivers increased capacity at times of high demand, allowing the room
target temperature to be reached as rapidly as possible from start up.

New 19 & 22kW models now available -


The unit size of these models has now been
significantly reduced as displayed here.

*1 Based on the following operating conditions - Place-Office in Tokyo, Japan / Operating time-8am to 8pm, 6 days/week / Operating period-Cooling: April 16 - November 8
Heating: December 14 - March 23 / Set temperature-Cooling: 27°C, Heating: 20˚C. Non-inverter model installed eight years ago is a PLH-3GKHB / PUH-3YKA.
Power Inverter model is a PLA-RP71BA2 / PUHZ-RP71VHA3.

Page 56
Silent Operation
Operation has been made near-silent (67% quieter than corresponding R22 outdoor unit*1) as a result of improvement
in the design of the fan blades and the new grille shape. The Power Inverter is even quieter at night when outside
temperatures drop, as it can be set to low-noise mode (cooling only) reducing operating noise by 3dBA (50% quieter than
normal day mode). A low-noise priority function is also available by connecting a separate commercially available timer or
selector switch. When a signal is received from the timer or switch, the unit automatically runs in low-noise mode.

Duty Standby Operation


3 new functions are available with Mr Slim systems* : 2

Rotation Rotate
2 outdoor units (master & sub) operate alternately,
switching every 1, 3, 5, 7, 14, 28 days (selectable).

Back Up
Back Up
When master outdoor unit fails,
sub unit begins operation.

Join In
When master outdoor unit fails to reach set Join In
temperature, sub unit operates in conjunction
(available in cooling mode only).

* 1 When comparing the Power Inverter (PUHZ-RP71VHA3) with R22 (PUH3-VKA) in cooling.
* 2 Not available when using SUZ outdoor units. Must be used in conjunction with a PAR-21MAA controller.

Page 57
Standard Inverter
The Standard Inverter models provide an inverter solution at a lower
capital cost than the Power Inverter range. These outdoor models continue
to offer high efficiency as standard, with some systems qualifying for
Enhanced Capital Allowance. Models are available in 10, 12.5 & 14kW single
phase and now 19 & 22kW three phase.

Improved COP / EER Figures - COP / EER figures have been improved
when compared to the previous R407c range.

COP
Example: COP
EER
Improved
COP
EER by 27%
2.61 2.69 3.01 3.41
D E B B
R407c Fixed speed unit Standard Inverter
PUH-P100VGAA PUHZ-P100VHA2

10.0kW model now has a Compared to Power Inverter


compact single fan design and Height reduced Weight reduced
weighs less, when compared by 407mm by 46kg
to its Power Inverter equivalent,
Power 121kg Standard 75kg
making installation easier. Inverter Inverter
407mm
1350mm

943mm

330mm 950mm 330mm 950mm

Silent Outdoor Unit - Low Noise Mode


1/2 the
Low noise mode can be set at night time to audible sound
(compared to
reduce noise levels by approximately 50%. daytime)

The example here is using a


Day 50dBA 3dBA
Less
Night 47dBA
Outdoor Temperature 35ºC Outdoor Temperature 25ºC
PUHZ-P100VHA2.

Page 58
Inverter solutions
at a lower price

SUZ outdoor units are able to be connected to selected Mr Slim indoor units, creating a new
range of low cost inverter driven systems.

Design with Environmental Consideration

Pump down switch


Pushing a switch
starts / stops refrigerant
recovery operation
automatically. This work
will then be completed
Pump down switch by closing a valve.

Smooth refrigerant recovery can be assured by pushing the pump down switch
at unit movement / renewal.

Page 59
New 4-Way Blow Cassette
The PLA-RP-BA(2) (PLFY-P-VBM-E for City Multi)
4-Way Blow Cassette, offers a range of new features,
as well as a new design and pure white colour.

I Previous product I New product


Wide Airflow
The new wide shape vane (capable of wide angle air supply) provides
comfort at the corners of a room, regardless of cooling or heating operation.
A reduction in the air speed by 20% (compared to the previous product)
eliminates the uncomfortable draft sensation often experienced.

Reduced
Reduced Draft Air Distribution Draft Air
Reduced draft air distribution allows the vanes to supply Distribution
airflow horizontally, thus preventing discomfort due to
excessive cooling or from direct exposure of occupants
to the air blow.

Independent Vane Control


If the airflow direction needs to be changed as a result of an altered Horizontal blow
room layout or due to the mode selected (i.e. cooling or heating), PAR-21MAA
the air direction of each vane can be set independently using
the PAR-21MAA wired remote controller. Adjustable Down blow Fixed

Automatic Airflow Grille with Automatic Filter Lowering


Adjustment Mode Function (Optional) Automatic
The automatic airflow adjustment mode is provided This grille can be operated by both the lowering
to
in addition to the 4 normal airflow stages and allows wired remote controller and the
4m
automatic adjustment of the airflow in accordance exclusive infra-red remote controller.
with the difference between the set temperature It can be lowered in 8 steps down to
and the room temperature. 4m in accordance with the ceiling height,
For example: The automatic airflow adjustment mode enabling you to easily clean the air filter.
allows quick cooling of a room using high mode, then Regular cleaning of the filter is an
when the room temperature has stabilised, the low important factor in saving energy.
mode will be applied to maximise comfort.

Automatic airflow
Low Medium 2 Medium 1 High adjustment

Elevation Grille PAR-21MAA


Remote Controller Wired Remote Controller
(comes with the grille)

Page 60
The (optional corner panel) Provides Even
Temperature Distribution and Reduces Energy Consumption
The “I-See Sensor” uses new temperature sensing technology developed by Mitsubishi Electric. In order
to create a comfortable environment in shops and offices, it is essential to control the temperature
near the floor where occupants and visitors gather. The “I-See Sensor” measures the infra-red rays
generated from the surrounding wall and floor surfaces and converts these into temperature values.
In addition, floor temperatures are also measured at distant spots, allowing optimum airflow
to reach these areas.

I “I-See Sensor”operation: The “I-See Sensor”rotates slowly in intervals of


5 seconds, correctly measuring the temperature of the entire floor space.
360°
The "I-See Sensor" rotates to
measure the floor temperature

5 seconds 5 seconds 5 seconds 5 seconds

“Sensible Temperature Control” to


Prevent Excessive Cooling and Heating
By measuring the inlet temperature and floor temperature, a temperature felt by the human body
(sensible temperature) will be calculated and maintained, suppressing excessive cooling and heating.

In the past... only the inlet temperature near With “I-See Sensor”... both the floor
the ceiling was measured, tending to overlook the temperature and inlet temperature are measured.
uneven temperature distribution near the floor.
The New 4-Way Blow Ceiling Cassette with the
Conventional air conditioning in shops and offices only “I-See Sensor” simultaneously measures the floor
measured the temperature near to the ceiling, therefore and inlet temperatures, providing improved comfort
the uneven temperature distribution between the ceiling to occupants and increased energy savings.
and the floor remained unchecked.
As a result, the set
Inlet temperature sensor Inlet temperature sensor
temperature tended
to be higher in order
to obtain comfort Area measured by the cassette
at floor level.
Area measured by cassette model
without "I-See Sensor" 360°
sensing
model equipped with "I-See Sensor"

With the
“I-See Sensor” 2.7m
Without plus automatic airflow
“I-See Sensor”. adjustment mode.
Set temperature is Set temperature is
23ºC (in Heating) 20ºC (in Heating)
e.g. 37ºC e.g. 37ºC
To achieve a sensible With the set temperature
temperature of 20ºC, 25ºC at 20ºC, a sensible 25ºC
the set temperature temperature of 20ºC at
must be as high as 23ºC 13ºC floor level can be obtained. 13ºC

Page 61
The adaptable Mr Slim range
Designed to fit
anywhere
Available in a variety of options, the Mr Slim range

fits in wherever it’s needed. Indoor units can be

four way blow cassettes, ducted,

wall or ceiling mounted. Up to four indoor

units can then be connected to a single outdoor unit

providing the ideal air conditioning solution.

Simple technology
at its best
Systems marked with the ECA logo have an energy label of A or B, are registered on the
Energy Technology List and hence qualify for 100% first year enhanced capital allowances
(whole system cost and ‘reasonable’ cost of installation). For further information please
go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 62
Contents
64 PKA-RP Power Inverter Heat Pump, Wall Mounted System
66 PKA-RP Standard Inverter Heat Pump, Wall Mounted System
68 PKA-RP Heat Pump, Wall Mounted System
70 SEZ-KD-VA Inverter Heat Pump, Ceiling Concealed Ducted System
72 PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System
74 PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System
76 PEAD-RP Heat Pump, Ceiling Concealed Ducted System
78 PEA-RP-GA Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
80 PEA-RP-GA Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
82 SLZ-KA-VA Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System
84 PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
86 PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
88 PLA-RP Heat Pump, 4-Way Blow Ceiling Cassette System
90 PCA-RP Power Inverter Heat Pump, Ceiling Suspended System
92 PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System
94 PCA-RP Heat Pump, Ceiling Suspended System
96 PCA-RP-HA Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System
98 PCA-RP-HA Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System
100 PCA-RP-HA Heat Pump, Stainless Steel Ceiling Suspended System
102 PSA-RP Power Inverter Heat Pump, Floor Standing System
104 PSA-RP Standard Inverter Heat Pump, Floor Standing System
106 PSA-RP Heat Pump, Floor Standing System
108 PHV DXE Heat Pump, Air Curtain
110 Mr Slim Multi-Split Systems Heat Pump
112 Outdoor Units
115 Air Handling Unit Controller
116 Mr Slim Accessories / Optional Extras

Page 63
PKA-RP Power Inverter Heat Pump
Wall Mounted System
I Adjustable louvres for uniform air distribution
I Internal pipe connection to wall mounted unit for easy and neat installation

Technical Information
PKA-RP - INDOOR UNITS
MODEL REFERENCE PKA-RP35GAL PKA-RP50FAL2 PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL
CAPACITY (kW) Heating (nominal) 3.6 (1.6-5.2) 6.0 (2.5-7.3) 7.0 (2.8-8.2) 7.6 (3.5-10.2) 11.2 (4.5-14.0)
Cooling (nominal) 3.6 (1.6-4.5) 5.0 (2.3-5.6) 6.0 (2.7-6.7) 7.1 (3.3-8.1) 10.0 (4.9-11.4)
Heating (UK) 3.05 (1.35-4.4) 5.1 (2.15-6.2) 5.95 (2.4-6.95) 6.45 (3.0-8.65) 9.5 (3.85-11.9)
Cooling (UK) 3.25 (1.45-4.05) 4.5 (2.05-5.05) 5.4 (2.45-6.05) 6.4 (2.95-7.3) 9.0 (4.4-10.25)
SHF (nominal) 0.87 0.86 0.83 0.77 0.77
COP / EER (nominal) 3.41 / 3.50 3.41 / 3.01 3.48 / 3.87 3.41 / 3.59 3.45 / 3.41
ENERGY LABEL Heating/Cooling B /A B/B B /A B /A B /A
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 9-10-11-12 15-20 15-20 15-20 22-28
PIPE SIZE mm(in) Gas 12.7 (1/2”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 36-38-41-43 39-45 39-45 39-45 41-46
DIMENSIONS (mm) Width 990 1400 1400 1400 1680
Depth 235 235 235 235 235
Height 340 340 340 340 340
WEIGHT (kg) 16 24 24 24 28
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single
FUSE RATING (BS88) – HRC (A) 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP35VHA3 PUHZ-RP50VHA3 PUHZ-RP60VHA3 PUHZ-RP71VHA3 PUHZ-RP100VHA3/YHA3
NOISE (dBA) Heating/Cooling 46 / 44 46 / 44 48 / 47 48 / 47 51 / 49
WEIGHT (kg) 42 42 68 68 116 / 130
DIMENSIONS (mm) Width 800 800 950 950 950
Depth 300 + 23 300 + 23 330 + 30 330 + 30 330 + 30
Height 600 600 943 943 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz / 380-415,50Hz
PHASE Single Single Single Single Single / 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.06 / 1.03 1.76 / 1.66 2.01 / 1.55 2.23 / 1.98 3.25 / 2.93
Heating/Cooling (UK) 0.94 / 0.86 1.57 / 1.41 1.79 / 1.32 2.00 / 1.68 2.89 / 2.49
STARTING CURRENT (A) 5 5 5 5 5
SYSTEM RUNNING CURRENT (A) Single Phase 4.56 / 4.34 [13] 6.9 / 6.59 [13] 7.93 / 7.04 [19] 10.17 / 8.47 [19] 12.91 / 13.05 [28]
Heating/Cooling [MAX] 3 Phase - - - - 4.55 / 4.60 [13]
FUSE RATING (BS88) - HRC (A) 16 16 25 25 32 / 16
MAINS CABLE No. Cores 3 3 3 3 3/5
MAX PIPE LENGTH (m) 50 50 50 50 75
MAX HEIGHT DIFFERENCE (m) 30 30 30 30 30
CHARGE R410A (kg) - 30m 2.5 2.5 3.5 3.5 5.0

Page 64
Mr Slim Range 2008
Dimensions

INDOOR UNIT PKA-RP35GAL

Lower Side View >

Left Side View > Front View > Right Side View >

INDOOR UNIT PKA-RP50-71FAL(2)

Lower Side View >

Left Side View > Front View > < Right Side View

PKA-RP Power Inverter Heat Pump


INDOOR UNIT PKA-RP100FAL

Lower Side View >

Left Side View > Front View > < Right Side View

Page 65
PKA-RP Standard Inverter Heat Pump
Wall Mounted System
The Standard Inverter range provides inverter solutions for
customers who want all the benefits that inverters offer,
but do not have the budget available for the more
expensive Power Inverter range.
I Adjustable louvres for uniform air distribution
I Internal pipe connection to wall mounted
unit for easy and neat installation

Technical Information
PKA-RP - INDOOR UNITS
MODEL REFERENCE PKA-RP100FAL
CAPACITY (kW) Heating (nominal) 11.2 (4.5-12.5)
Cooling (nominal) 9.4 (4.9-11.2)
Heating (UK) 9.5 (3.85-10.65)
Cooling (UK) 8.45 (4.4-10.1)
SHF (nominal) 0.79
COP / EER (nominal) 3.21 / 3.01
ENERGY LABEL Heating/Cooling C/B
AIRFLOW (m3/min) Lo-Hi 22-28
PIPE SIZE mm(in) Gas 15.88 (5/8”)
Liquid 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 41-46
DIMENSIONS (mm) Width 1680
Depth 235
Height 340
WEIGHT (kg) 28
ELECTRICAL SUPPLY Fed by Outdoor Unit
PHASE Single
FUSE RATING (BS88) - HRC (A) 6
INTERCONNECTING CABLE No. CORES 4

PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE PUHZ-P100VHA2
NOISE (dBA) Heating/Cooling 54 / 50
WEIGHT (kg) 75
DIMENSIONS (mm) Width 950
Depth 330 + 30
Height 943
ELECTRICAL SUPPLY 220-240v, 50Hz
PHASE Single
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 3.49 / 3.12
Heating/Cooling (UK) 3.11 / 2.65
STARTING CURRENT (A) 4
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 13.14 / 12.78 [28]
FUSE RATING (BS88) - HRC (A) 32
MAINS CABLE No. Cores 3
MAX PIPE LENGTH (m) 50
MAX HEIGHT DIFFERENCE (m) 30
CHARGE R410A (kg) - 20m 2.7

Page 66
Mr Slim Range 2008
Dimensions

INDOOR UNIT PKA-RP100FAL

Lower Side View >

Left Side View > Front View > < Right Side View

PKA-RP Standard Inverter Heat Pump

Page 67
PKA-RP Heat Pump
Wall Mounted System
The Heat Pump system provides a low cost
alternative to three phase Power Inverter systems.

I Adjustable louvres for uniform air distribution


I Internal pipe connection to wall mounted unit
for easy and neat installation

Technical Information
PKA-RP - INDOOR UNITS
MODEL REFERENCE PKA-RP100FAL
CAPACITY (kW) Heating (nominal) 11.5
Cooling (nominal) 9.8
Heating (UK) 9.8
Cooling (UK) 8.8
SHF (nominal) 0.77
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 22-28
PIPE SIZE mm(in) Gas 15.88 (5/8”)
Liquid 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 41-46
DIMENSIONS (mm) Width 1680
Depth 235
Height 340
WEIGHT (kg) 28
ELECTRICAL SUPPLY Fed by Outdoor Unit
PHASE Single
FUSE RATING (BS88) - HRC (A) 6
INTERCONNECTING CABLE No. CORES 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE PUH-P100YHA
NOISE (dBA) Heating/Cooling 52 / 50
WEIGHT (kg) 94
DIMENSIONS (mm) Width 950
Depth 330 + 30
Height 943
ELECTRICAL SUPPLY 380-415v, 50Hz
PHASE 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 3.47 / 3.50
Heating/Cooling (UK) 3.09 / 2.98
STARTING CURRENT (A) 45
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 5.7 / 5.91 [11.8]
FUSE RATING (BS88) - HRC (A) 20
MAINS CABLE No. Cores 5
MAX PIPE LENGTH (m) 50
MAX HEIGHT DIFFERENCE (m) 50
CHARGE R410A (kg) - 30m 4.4

Page 68
Mr Slim Range 2008
Dimensions

INDOOR UNIT PKA-RP100FAL

Lower Side View >

Left Side View > Front View > < Right Side View

PKA-RP Heat Pump

Page 69
SEZ-KD-VA Inverter Heat Pump
Ceiling Concealed Ducted System
Designed for homes, offices, restaurants or shops, the SEZ-KD-VA series
operates at low noise levels. Its new improved low unit height and
lightweight design also help to make installation easier and
more convenient.

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available.
Please see accessories / optional extras section.
Technical Information
SEZ-KD-VA - INDOOR UNITS
MODEL REFERENCE SEZ-KD25VA SEZ-KD35VA SEZ-KD50VA SEZ-KD60VA SEZ-KD71VA
CAPACITY (kW) Heating (nominal) 3.0 (0.9-4.5) 4.0 (0.9-5.0) 6.0 (1.1-7.2) 7.0 (0.9-8.0) 8.1 (0.9-10.4)
Cooling (nominal) 2.5 (0.9-3.2) 3.5 (1.0-3.9) 5.0 (1.1-5.6) 5.5 (1.1-6.3) 7.1 (0.9-8.3)
Heating (UK) 2.5 (0.75-3.75) 3.3 (0.75-4.15) 5.0 (0.9-6.0) 5.8 (0.75-6.65) 6.75 (0.75-8.65)
Cooling (UK) 2.5 (0.9-3.15) 3.45 (1.0-3.85) 4.95 (1.1-5.55) 5.45 (1.1-6.25) 7.05 (0.9-8.25)
SHF (nominal) 0.80 0.78 0.76 0.79 0.74
COP / EER (nominal) 3.61 / 3.21 3.61 / 3.21 3.21 / 2.81 3.41 / 2.91 3.42 / 2.81
ENERGY LABEL Heating/Cooling A /A A /A C/C B/C B/C
AIRFLOW (m3/min) Lo-Mi-Hi 5.5-7.0-9.0 7-9-11 10-12.5-15 12-15-18 12-16-20
EXTERNAL STATIC PRESSURE Pa Lo-Mi1-Mi2-Hi 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50
PIPE SIZE mm(in) Gas 9.52 (3/8”) 9.52 (3/8”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi-Hi 23-26-30 23-28-33 30-34-37 30-34-38 30-35-40
DIMENSIONS (mm) Width 790 990 990 1190 1190
Depth 700 700 700 700 700
Height 200 200 200 200 200
WEIGHT (kg) 18 21 23 27 27
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4

SUZ-KA-VA - OUTDOOR UNITS


MODEL REFERENCE SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA SUZ-KA60VA SUZ-KA71VA
NOISE (dBA) (Lo-Hi) Heating/Cooling 46 / 46 48 / 47 53-55 / 51-53 53-55 / 51-53 53-55 / 51-53
WEIGHT (kg) 33 37 53 53 58
DIMENSIONS (mm) Width 800 800 840 840 840
Depth 285 285 330 330 330
Height 550 550 850 850 850
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 0.83 / 0.778 1.108 / 1.09 1.87 / 1.78 2.05 / 1.89 2.37 / 2.53
Heating/Cooling (UK) 0.76 / 0.62 1.01 / 0.87 1.70 / 1.42 1.87 / 1.51 2.15 / 2.02
STARTING CURRENT (A) 3.65 4.75 6.75 9.75 10.3
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 4.04 / 3.44 [8.16] 5.21 / 5.01 [9.18] 6.98 / 7.38 [16] 10.38 / 8.98 [16] 10.74 / 11.14 [16]
FUSE RATING (BS88) - HRC (A) 16 16 25 25 25
MAINS CABLE No. CORES 3 3 3 3 3
MAX PIPE LENGTH (m) 20 20 30 30 30
MAX HEIGHT DIFFERENCE (m) 12 12 30 30 30
CHARGE R410A (kg) - 7m 0.9 1.05 1.6 1.8 2.0

Page 70
Mr Slim Range 2008
Dimensions

INDOOR UNIT SEZ-KD25-71VA

Upper View >

Front View >

Side View >


SEZ-KD-VA Inverter Heat Pump

Models A B C D E F

Size 25 700 752 798 660 7 600

Size 35-50 900 952 998 860 9 800

Size 60-71 1100 1152 1198 1060 11 1000

Page 71
PEAD-RP Power Inverter Heat Pump
Ceiling Concealed Ducted System

Technical Information
PEAD-RP - INDOOR UNITS
MODEL REFERENCE PEAD-RP35EA2 PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA

CAPACITY (kW) Heating (nominal) 4.1 (1.6-5.2) 6.0 (2.5-7.3) 7.0 (2.8-8.2) 8.0 (3.5-10.2) 11.2 (4.5-14.0) 14.0 (5.0-16.0) 16.0 (5.0-18.0)
Cooling (nominal) 3.6 (1.6-4.5) 4.9 (2.3-5.6) 6.0 (2.7-6.7) 7.1 (3.3-8.1) 10.0 (4.9-11.4) 12.5 (5.5-14.0) 14.0 (5.5-15.3)
Heating (UK) 3.5 (1.35-4.4) 5.1 (2.15-6.2) 5.95 (2.4-6.95) 6.8 (3.0-8.65) 9.5 (3.85-11.9) 11.9 (4.25-13.6) 13.6 (4.25-15.3)
Cooling (UK) 3.25 (1.45-4.05) 4.4 (2.05-5.05) 5.4 (2.45-6.05) 6.4 (2.95-7.3) 9.0 (4.4-10.25) 11.25 (4.95-12.6) 12.6 (4.95-13.75)
SHF (nominal) 0.89 0.82 0.79 0.83 0.86 0.82 0.83
COP / EER (nominal) 3.41 / 3.21 3.64 / 3.22 3.68 / 3.23 3.42 / 3.30 3.51 / 3.27 3.61 / 3.21 3.41 / 3.01
ENERGY LABEL Heating/Cooling B /A A /A A /A B /A B /A A /A B/B
AIRFLOW (m3/min) Lo-Hi 13.5-17 13.5-17 17-21 20-25 33.5-42 33.5-42 36.5-46
PIPE SIZE mm(in) Gas 12.7 (1/2”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
EXTERNAL STATIC PRESSURE (Pa) Lo-Hi 30-70 30-70 30-70 70-130*1 70-130*2 70-130*3 70-130*3
NOISE (dBA) Lo-Hi (*4) 36-40 (38-44) 36-40 (38-44) 37-41 (39-46) 37-41 (40-45) 44-50 (46-52) 44-50 (46-52) 46-51 (47-53)
DIMENSIONS (mm) Width 935 935 1175 1175 1415 1415 1715
Depth 700 700 700 740 740 740 740
Height 295 295 295 325 325 325 325
WEIGHT (kg) 33 35 42 44 65 65 70
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4 4 4
Notes: External static pressure - (35-60: 30 + 70Pa connections as standard) / (71-140: 130Pa optional fan motor - *1 PAC-SK005MT-F, *2 PAC-SK004MT-F, *3 PAC-SK003MT-F).
*4 70Pa (35-60) / 130Pa optional fan motor (71-140).

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP35VHA3 PUHZ-RP50VHA3 PUHZ-RP60VHA3 PUHZ-RP71VHA3 PUHZ-RP100VHA3/YHA3 PUHZ-RP125VHA2/YHA2 PUHZ-RP140VHA2/YHA2
NOISE (dBA) Heating/Cooling 46 / 44 46 / 44 48 / 47 48 / 47 51 / 49 52 / 50 52 / 50
WEIGHT (kg) 42 42 68 68 116 / 130 116 / 130 116 / 130
DIMENSIONS (mm) Width 800 800 950 950 950 950 950
Depth 300 + 23 300 + 23 330 + 30 330 + 30 330 + 30 330 + 30 330 + 30
Height 600 600 943 943 1350 1350 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz
PHASE Single Single Single Single Single / 3 Single / 3 Single / 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.20 / 1.12 1.65 / 1.52 1.90 / 1.86 2.34 / 2.15 3.19 / 3.06 3.88 / 3.89 4.69 / 4.65
Heating/Cooling (UK) 1.05 / 0.95 1.47 / 1.29 1.69 / 1.58 2.08 / 1.83 2.84 / 2.60 3.45 / 3.31 4.17 / 3.95
STARTING CURRENT (A) 5 5 5 5 5 5 5
SYSTEM RUNNING CURRENT (A) Single Phase 4.84 / 4.62 [13] 7.08 / 6.77 [13] 8.2 / 7.31 [19] 11.29 / 9.59 [19] 15.01 / 15.15 [28] 18.6 / 18.15 [28] 22.61 / 22.34 [29.5]
Heating/Cooling [MAX] 3 Phase - - - - 6.65 / 6.70 [13] 7.82 / 7.66 [13] 9.15 / 9.06 [13]
FUSE RATING (BS88) - HRC (A) 16 16 25 25 32 / 16 32 / 16 40 / 16
MAINS CABLE No. Cores 3 3 3 3 3/5 3/5 3/5
MAX PIPE LENGTH (m) 50 50 50 50 75 75 75
MAX HEIGHT DIFFERENCE (m) 30 30 30 30 30 30 30
CHARGE R410A (kg) - 30m 2.5 2.5 3.5 3.5 5.0 5.0 5.0

Page 72
Mr Slim Range 2008
Dimensions

INDOOR UNIT PEAD-RP35-60EA(2)

Upper View > Front View >

Side View >

Models A B C D E
Size 35-50 772 305 - 830 804
Size 60 1012 280 290 1070 1044

INDOOR UNIT PEAD-RP71-140EA(2)

Upper View >

PEAD-RP Power Inverter Heat Pump

Side View >


Front View >

Models A B C D E
Size 71 1012 280 290 1070 1044
Size 100-125 1252 360 370 1310 1284
Size 140 1552 460 470 1610 1584

Page 73
PEAD-RP Standard Inverter Heat Pump
Ceiling Concealed Ducted System
The Standard Inverter range provides inverter solutions
for customers who want all the benefits that inverters offer,
but do not have the budget available for the more expensive
Power Inverter range.

Technical Information
PEAD-RP - INDOOR UNITS
MODEL REFERENCE PEAD-RP35EA2 PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA
CAPACITY (kW) Heating (nominal) 4.1 (0.9-5.0) 5.9 (0.9-7.2) 7.0 (0.9-8.0) 8.0 (0.9-10.2) 11.2 (4.5-12.5) 14.0 (5.0-16.0) 16.0 (5.0-18.0)
Cooling (nominal) 3.6 (1.0-3.9) 4.9 (1.1-5.6) 6.0 (1.1-6.3) 7.1 (0.9-8.1) 9.4 (4.9-11.2) 12.3 (5.5-14.0) 13.6 (5.5-15.0)
Heating (UK) 3.4 (0.75-4.15) 4.9 (0.75-6.0) 5.8 (0.75-6.65) 6.65 (0.75-8.5) 9.5 (3.85-10.65) 11.9 (4.25-13.6) 13.6 (4.25-15.3)
Cooling (UK) 3.55 (1.0-3.85) 4.85 (1.1-5.55) 5.95 (1.1-6.25) 7.05 (0.9-8.05) 8.45 (4.4-10.1) 11.05 (4.95-12.6) 12.25 (4.95-13.5)
SHF (nominal) 0.90 0.79 0.80 0.81 0.86 0.83 0.84
COP / EER (nominal) 3.63 / 3.21 3.49 / 2.82 3.38 / 2.93 3.21 / 2.81 3.41 / 3.01 3.41 / 2.81 3.21 / 2.61
ENERGY LABEL Heating/Cooling A /A B/C C/C C/C B/B B/C C/D
AIRFLOW (m3/min) Lo-Hi 13.5-17 13.5-17 17-21 20-25 33.5-42 33.5-42 36.5-46
PIPE SIZE mm(in) Gas 9.52 (3/8”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
EXTERNAL STATIC PRESSURE (Pa) Lo-Hi 30-70 30-70 30-70 70-130*1 70-130*2 70-130*3 70-130*3
NOISE (dBA) Lo-Hi (*4) 36-40 (38-44) 36-40 (38-44) 37-41 (39-46) 37-41 (40-45) 44-50 (46-52) 44-50 (46-52) 46-51 (47-53)
DIMENSIONS (mm) Width 935 935 1175 1175 1415 1415 1715
Depth 700 700 700 740 740 740 740
Height 295 295 295 325 325 325 325
WEIGHT (kg) 33 35 42 44 65 65 70
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4 4 4

Notes: External static pressure - (35-60: 30 + 70Pa connections as standard) / (71-140: 130Pa optional fan motor - *1 PAC-SK005MT-F, *2 PAC-SK004MT-F, *3 PAC-SK003MT-F).
*4 70Pa (35-60) / 130Pa optional fan motor (71-140).

SUZ-KA / PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE SUZ-KA35VA SUZ-KA50VA SUZ-KA60VA SUZ-KA71VA PUHZ-P100VHA2 PUHZ-P125VHA2 PUHZ-P140VHA2
NOISE (dBA) (Lo-Hi) Heating/Cooling 48 / 47 53-55 / 51-53 53-55 / 51-53 53-55 / 51-53 54 / 50 55 / 51 56 / 52
WEIGHT (kg) 37 53 53 58 75 99 99
DIMENSIONS (mm) Width 800 840 840 840 950 950 950
Depth 285 330 330 330 330 + 30 330 + 30 330 + 30
Height 550 850 850 850 943 1350 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single Single Single
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.13 / 1.12 1.69 / 1.74 2.07 / 2.05 2.49 / 2.53 3.28 / 3.12 4.11 / 4.38 4.98 / 5.21
Heating/Cooling (UK) 1.03 / 0.90 1.54 / 1.39 1.88 / 1.64 2.27 / 2.02 2.92 / 2.65 3.66 / 3.72 4.43 / 4.43
STARTING CURRENT (A) 4.75 6.75 9.75 10.3 4 14 14
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 5.36 / 5.16 [9.18] 6.96 / 7.36 [16] 10.45 / 9.05 [16] 11.45 / 11.85 [16] 15.24 / 14.88 [28] 19.36 / 19.99 [28] 24.00 / 25.17 [29.5]
FUSE RATING (BS88) - HRC (A) 16 25 25 25 32 32 40
MAINS CABLE No. Cores 3 3 3 3 3 3 3
MAX PIPE LENGTH (m) 20 30 30 30 50 50 50
MAX HEIGHT DIFFERENCE (m) 12 30 30 30 30 30 30
CHARGE R410A (kg) 1.05 1.6 1.8 2.0 2.7 4.5 4.5

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Page 74
Mr Slim Range 2008
Dimensions

INDOOR UNIT PEAD-RP35-60EA(2)

Upper View > Front View >

Side View >

Models A B C D E
Size 35-50 772 305 - 830 804
Size 60 1012 280 290 1070 1044

INDOOR UNIT PEAD-RP71-140EA(2)

Upper View >

PEAD-RP Standard Inverter Heat Pump

Side View >


Front View >

Models A B C D E
Size 71 1012 280 290 1070 1044
Size 100-125 1252 360 370 1310 1284
Size 140 1552 460 470 1610 1584

Page 75
PEAD-RP Heat Pump
Ceiling Concealed Ducted System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

Technical Information
PEAD-RP - INDOOR UNITS
MODEL REFERENCE PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA
CAPACITY (kW) Heating (nominal) 11.5 14.3 16.7
Cooling (nominal) 10.0 12.3 14.2
Heating (UK) 9.8 12.2 14.2
Cooling (UK) 9.0 11.05 12.8
SHF (nominal) 0.86 0.82 0.83
AIRFLOW (m3/min) Lo-Hi 33.5-42 33.5-42 36.5-46
PIPE SIZE mm(in) Gas 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
EXTERNAL STATIC PRESSURE (Pa) Lo-Hi 70-130*1 70-130*2 70-130*2
NOISE (dBA) Lo-Hi (*3) 44-50 (46-52) 44-50 (46-52) 46-51 (47-53)
DIMENSIONS (mm) Width 1415 1415 1715
Depth 740 740 740
Height 325 325 325
WEIGHT (kg) 65 65 70
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4

Notes: External static pressure - (100-140: 130Pa optional fan motor - *1 PAC-SK004MT-F, *2 PAC-SK003MT-F). *3 130Pa optional fan motor (100-140).

PUH-P - OUTDOOR UNITS


MODEL REFERENCE PUH-P100YHA PUH-P125YHA PUH-P140YHA
NOISE (dBA) Heating/Cooling 52 / 50 52 / 50 53 / 51
WEIGHT (kg) 94 131 131
DIMENSIONS (mm) Width 950 950 950
Depth 330 + 30 330 + 30 330 + 30
Height 943 1350 1350
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 3.42 / 3.69 4.32 / 4.41 5.28 / 5.63
Heating/Cooling (UK) 3.04 / 3.14 3.85 / 3.75 4.70 / 4.79
STARTING CURRENT (A) 45 70 85
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 7.8 / 8.01 [13.9] 9.19 / 9.41 [17.8] 11.14 / 11.24 [21.5]
FUSE RATING (BS88) - HRC (A) 20 20 25
MAINS CABLE No. Cores 5 5 5
MAX PIPE LENGTH (m) 50 50 50
MAX HEIGHT DIFFERENCE (m) 50 50 50
CHARGE R410A (kg) - 30m 4.4 5.0 5.0

Page 76
Mr Slim Range 2008
Dimensions

INDOOR UNIT PEAD-RP100-140EA(2)

Upper View >

Models A B C D E
Size 100-125 1252 360 370 1310 1284
Size 140 1552 460 470 1610 1584

Front View >

Side View >


PEAD-RP Heat Pump

Page 77
PEA-RP-GA Power Inverter Heat Pump
Large Capacity Ceiling Concealed Ducted System
I Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units
I Static pressure of up to 150Pa
I Outdoor unit size reduced by approx 33%, with height being reduced by 66%
(compared to previous model)

Technical Information
PEA-RP-GA - INDOOR UNITS
MODEL REFERENCE PEA-RP200GA PEA-RP250GA PEA-RP400GA PEA-RP500GA
CAPACITY (kW) Heating (nominal) 22.4 (9.5-25.0) 27.0 (12.5-31.5) 44.8 (18.0-50.0) 54.0 (25.0-63.0)
Cooling (nominal) 19.0 (9.0-22.4) 22.0 (11.2-28.0) 38.0 (18.0-44.8) 44.0 (22.4-56.0)
Heating (UK) 19.05 (8.1-21.25) 22.95 (10.65-26.8) 38.1 (15.3-42.5) 45.9 (21.25-53.55)
Cooling (UK) 17.1 (8.3-21.15) 19.8 (10.3-25.2) 34.95 (16.55-41.2) 40.5 (20.6-51.5)
SHF (nominal) 0.81 0.86 0.75 0.77
COP / EER (nominal) 3.45 / 2.84 3.29 / 2.64 3.56 / 2.93 3.20 / 2.56
ENERGY LABEL Heating/Cooling B / C C / D B / C D / E
AIRFLOW (m3/min) Lo-Hi 52-65 64-80 120 160
PIPE SIZE mm(in) Gas 28.58 (1 1/8”) 28.58 (1 1/8”) 28.58 (1 1/8”) x2 28.58 (1 1/8”) x2
Liquid 9.52 (3/8”) 12.7 (1/2”) 9.52 (3/8”) x2 12.7 (1/2”) x2
EXTERNAL STATIC PRESSURE (Pa) 150 150 150 150
NOISE (dBA) Lo-Hi 48-51 49-52 52 53
DIMENSIONS (mm) Width 1400 1600 1947 1947
Depth 634 634 764 764
Height 400 400 595 595
WEIGHT (kg) 70 77 130 133
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3
POWER INPUT (kW) (nominal) 1.00 1.18 1.55 2.84
(UK) 0.89 1.05 1.38 2.53
STARTING CURRENT (A) 5.6 5.6 8.7 10
RUNNING CURRENT (A) [Max] 2.0 [2.4] 2.3 [2.8] 3.8 [4.6] 5.4 [6.5]
FUSE RATING (BS88) – HRC (A) 6 6 10 10
MAINS CABLE No. Cores 5 5 5 5
INTERCONNECTING CABLE No. CORES 3 3 3 3

PUHZ-RP-YHA2 - OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP200YHA2 PUHZ-RP250YHA2 PUHZ-RP200YHA2 x2 PUHZ-RP250YHA2 x2
NOISE (dBA) Heating/Cooling 59 / 58 59 / 58 59 / 58 59 / 58
WEIGHT (kg) 135 136 135 136
DIMENSIONS (mm) Width 950 950 950 950
Depth 330+30 330+30 330+30 330+30
Height 1350 1350 1350 1350
ELECTRICAL SUPPLY 380-415v, 50Hz 330-415v, 50Hz 380-415v, 50Hz 330-415v, 50Hz
PHASE 3 3 3 3
POWER INPUT (kW) Heating/Cooling (nominal) 5.5 / 5.7 7.02 / 7.16 5.5 / 5.7 7.02 / 7.16
Heating/Cooling (UK) 4.9 / 4.85 6.25 / 6.09 4.9 / 4.85 6.25 / 6.09
STARTING CURRENT (A) 5 5 5 5
RUNNING CURRENT (A) [Max] Heating/Cooling 8.9 / 7.7 [19] 11.1 / 9.5 [21] 8.9 / 7.7 [19] 11.1 / 9.5 [21]
FUSE RATING (BS88) – HRC (A) 32 32 32 32
MAINS CABLE No. Cores 5 5 5 5
MAX PIPE LENGTH (m) 120 120 120 per outdoor 120 per outdoor
MAX HEIGHT DIFFERENCE (m) 30 30 30 30
CHARGE R410A (kg) - 30m 6.5 7.1 6.5 7.1

Page 78
Mr Slim Range 2008
Dimensions

INDOOR UNIT PEA-RP200GA

Front View >

Side View >


Upper View >

INDOOR UNIT PEA-RP250GA

Front View >

Side View >


Upper View >

PEA-RP-GA Power Inverter Heat Pump


INDOOR UNIT PEA-RP400-500GA

Front View >

Side View >


Upper View >

Page 79
PEA-RP-GA Standard Inverter Heat Pump
Large Capacity Ceiling Concealed Ducted System
The Standard Inverter range provides inverter solutions for customers who want all the benefits that
inverters offer, but do not have the budget available for the more expensive Power Inverter range.

I Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units
I Static pressure of up to 150Pa

Technical Information
PEA-RP-GA - INDOOR UNITS
MODEL REFERENCE PEA-RP200GA PEA-RP250GA PEA-RP400GA PEA-RP500GA
CAPACITY (kW) Heating (nominal) 22.4 (9.5-25.0) 27.0 (12.5-31.5) 44.8 (19.0-50.0) 54.0 (25.0-63.0)
Cooling (nominal) 19.0 (9.0-22.4) 22.0 (11.2-28.0) 38.0 (18.0-44.8) 44.0 (22.4-56.0)
Heating (UK) 19.05 (8.1-21.25) 22.95 (10.65-26.8) 38.1 (16.15-42.5) 45.9 (21.25-53.55)
Cooling (UK) 17.1 (8.3-21.15) 19.8 (10.3-25.2) 34.95 (16.55-41.2) 40.5 (20.6-51.5)
SHF (nominal) 0.81 0.86 0.75 0.77
COP / EER (nominal) 3.04 / 2.64 3.19 / 2.61 3.14 / 2.72 3.10 / 2.53
ENERGY LABEL Heating/Cooling D / D D / D D / D D / E
AIRFLOW (m3/min) Lo-Hi 52-65 64-80 120 160
PIPE SIZE mm(in) Gas 28.58 (1 1/8”) 28.58 (1 1/8”) 28.58 (1 1/8”) x2 28.58 (1 1/8”) x2
Liquid 9.52 (3/8”) 12.7 (1/2”) 9.52 (3/8”) x2 12.7 (1/2”) x2
EXTERNAL STATIC PRESSURE (Pa) 150 150 150 150
NOISE (dBA) Lo-Hi 48-51 49-52 52 53
DIMENSIONS (mm) Width 1400 1600 1947 1947
Depth 634 634 764 764
Height 400 400 595 595
WEIGHT (kg) 70 77 130 133
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3
POWER INPUT (kW) (nominal) 1.00 1.18 1.55 2.84
(UK) 0.89 1.05 1.38 2.53
STARTING CURRENT (A) 5.6 5.6 8.7 10
RUNNING CURRENT (A) [Max] 2.0 [2.4] 2.3 [2.8] 3.8 [4.6] 5.4 [ 6.5]
FUSE RATING (BS88) – HRC (A) 6 6 10 10
MAINS CABLE No. Cores 5 5 5 5
INTERCONNECTING CABLE No. CORES 3 3 3 3

PUHZ-P-YHA - OUTDOOR UNITS


MODEL REFERENCE PUHZ-P200YHA PUHZ-P250YHA PUHZ-P200YHA x2 PUHZ-P250YHA x2
NOISE (dBA) Heating/Cooling 59 / 59 59 / 59 59 / 59 59 / 59
WEIGHT (kg) 126 133 126 133
DIMENSIONS (mm) Width 950 950 950 950
Depth 330+30 330+30 330+30 330+30
Height 1350 1350 1350 1350
ELECTRICAL SUPPLY 380-415v, 50Hz 330-415v, 50Hz 380-415v, 50Hz 330-415v, 50Hz
PHASE 3 3 3 3
POWER INPUT (kW) Heating/Cooling (nominal) 6.36 / 6.21 7.29 / 7.26 6.36 / 6.21 7.29 / 7.26
Heating/Cooling (UK) 5.66 / 5.28 6.49 / 6.17 5.66 / 5.28 6.49 / 6.17
STARTING CURRENT (A) 5 5 5 5
RUNNING CURRENT (A) [Max] Heating/Cooling 9.88 / 9.47 [ 19 ] 12.0 / 11.0 [ 21 ] 9.88 / 9.47 [ 19 ] 12.0 / 11.0 [ 21 ]
FUSE RATING (BS88) – HRC (A) 32 32 32 32
MAINS CABLE No. Cores 5 5 5 5
MAX PIPE LENGTH (m) 70 70 70 per outdoor 70 per outdoor
MAX HEIGHT DIFFERENCE (m) 30 30 30 30
CHARGE R410A (kg) - 30m 5.8 7.1 5.8 7.1

Page 80
Mr Slim Range 2008
Dimensions

INDOOR UNIT PEA-RP200GA

Front View >

Side View >


Upper View >

INDOOR UNIT PEA-RP250GA

Front View >

Side View >


Upper View >

PEA-RP-GA Standard Inverter Heat Pump


INDOOR UNIT PEA-RP400-500GA

Front View >

Side View >


Upper View >

Page 81
SLZ-KA-VA Inverter Heat Pump
600x600 4-Way Blow Ceiling Cassette System
The SLZ-KA-VA series is perfect for both residential and
small business applications, as it offers inverter technology
alongside quiet operation. The compact size of this unit
is ideal for 600 by 600mm ceilings and with a depth of
208mm, this lightweight unit makes installation a breeze.
This unit also comes complete with a long life filter
that will last for approximately 2,500 hours.

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available.
Please see accessories / optional extras section.
Technical Information
SLZ-KA-VA - INDOOR UNITS
MODEL REFERENCE SLZ-KA25VA SLZ-KA35VA SLZ-KA50VA
CAPACITY (kW) Heating (nominal) 3.0 (0.9-4.5) 4.0 (0.9-5.0) 5.0 (0.9-6.5)
Cooling (nominal) 2.5 (0.9-3.2) 3.5 (1.0-3.9) 4.6 (1.1-5.2)
Heating (UK) 2.5 (0.75-3.75) 3.3 (0.75-4.15) 4.15 (0.75-5.4)
Cooling (UK) 2.5 (0.9-3.15) 3.45 (1.0-3.85) 4.55 (1.1-5.15)
SHF (nominal) 0.86 0.77 0.68
COP / EER (nominal) 3.61 / 3.62 3.64 / 3.30 3.23 / 2.82
ENERGY LABEL Heating/Cooling A /A A /A C/C
AIRFLOW (m3/min) Lo-Mi-Hi 8-9-10 8-9-11 8-9-11
PIPE SIZE mm(in) Gas 9.52 (3/8”) 9.52 (3/8”) 12.7 (1/2”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”)
NOISE (dBA) Lo-Mi-Hi 28-31-37 29-33-38 30-34-39
DIMENSIONS (mm) (grille) Width 570 (650) 570 (650) 570 (650)
Depth 570 (650) 570 (650) 570 (650)
Height 208 (20) 208 (20) 208 (20)
WEIGHT (kg) Unit 16.5 16.5 16.5
Grille 3 3 3
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4

SUZ-KA-VA - OUTDOOR UNITS


MODEL REFERENCE SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA
NOISE (dBA) (Lo-Hi) Heating/Cooling 46 / 46 48 / 47 53-55 / 51-53
WEIGHT (kg) 33 37 53
DIMENSIONS (mm) Width 800 800 840
Depth 285 285 330
Height 550 550 850
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 0.83 / 0.69 1.10 / 1.06 1.55 / 1.63
Heating/Cooling (UK) 0.76 / 0.55 1.00 / 0.85 1.41 / 1.30
STARTING CURRENT (A) 3.65 4.75 6.75
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 4.0 / 3.4 [8.16] 5.15 / 4.95 [9.18] 7.0 / 7.4 [16]
FUSE RATING (BS88) - HRC (A) 16 16 25
MAINS CABLE No. CORES 3 3 3
MAX PIPE LENGTH (m) 20 20 30
MAX HEIGHT DIFFERENCE (m) 12 12 30
CHARGE R410A (kg) - 7m 0.9 1.05 1.6

Page 82
Mr Slim Range 2008
Dimensions

INDOOR UNIT SLZ-KA25-50VA

Lower View >

Side View >

SLZ-KA-VA Inverter Heat Pump

Page 83
PLA-RP Power Inverter Heat Pump
4-Way Blow Ceiling Cassette System
I Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
I Reduced draft air distribution, with independent vane control
I Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
I Optional ‘I See Sensor' for energy saving and smooth temperature
control throughout the room

Technical Information
PLA-RP - INDOOR UNITS
MODEL REFERENCE PLA-RP35BA PLA-RP50BA PLA-RP60BA PLA-RP71BA2 PLA-RP100BA2 PLA-RP125BA2 PLA-RP140BA
CAPACITY (kW) Heating (nominal) 4.1 (1.6-5.2) 6.0 (2.5-7.3) 7.0 (2.8-8.2) 8.0 (3.5-10.2) 11.2 (4.5-14.0) 14.0 (5.0-16.0) 16.0 (5.0-18.0)
Cooling (nominal) 3.6 (1.6-4.5) 5.0 (2.3-5.6) 6.0 (2.7-6.7) 7.1 (3.3-8.1) 10.0 (4.9-11.4) 12.5 (5.5-14.0) 14.0 (5.5-15.3)
Heating (UK) 3.5 (1.35-4.4) 5.1 (2.15-6.2) 5.95 (2.4-6.95) 6.8 (3.0-8.65) 9.5 (3.85-11.9) 11.9 (4.25-13.6) 13.6 (4.25-15.3)
Cooling (UK) 3.25 (1.45-4.05) 4.5 (2.05-5.05) 5.4 (2.45-6.05) 6.4 (2.95-7.3) 9.0 (4.4-10.25) 11.25 (4.95-12.6) 12.6 (4.95-13.75)
SHF (nominal) 0.84 0.81 0.76 0.81 0.79 0.81 0.71
COP / EER (nominal) [3 Phase] 3.66 / 3.36 3.61 / 3.23 3.78 / 3.64 4.21 / 3.66 4.41/4.10 [4.31/4.00] 3.99/3.35 [3.92/3.30] 3.61 / 3.01
ENERGY LABEL Heating/Cooling A /A A /A A /A A /A A /A A /A A/B
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 11-12-13-15 12-14-16-18 12-14-16-18 14-16-18-21 20-23-26-30 22-25-28-31 24-26-29-32
PIPE SIZE mm(in) Gas 12.7 (1/2”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 27-28-29-31 28-29-31-32 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41 36-39-42-44
DIMENSIONS (mm) Width 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
(Grille) Depth 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Height 258 (35) 258 (35) 258 (35) 258 (35) 298 (35) 298 (35) 298 (35)
WEIGHT (kg) Unit 22 22 23 23 27 27 27
Panel 6 6 6 6 6 6 6
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4 4 4
GRILLE REFERENCE PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA
WIRED REMOTE CONTROLLER REFERENCE PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP35VHA3 PUHZ-RP50VHA3 PUHZ-RP60VHA3 PUHZ-RP71VHA3 PUHZ-RP100VHA3/YHA3 PUHZ-RP125VHA2/YHA2 PUHZ-RP140VHA2/YHA2
NOISE (dBA) Heating/Cooling 46 / 44 46 / 44 48 / 47 48 / 47 51 / 49 52 / 50 52 / 50
WEIGHT (kg) 42 42 68 68 116 / 130 116 / 130 116 / 130
DIMENSIONS (mm) Width 800 800 950 950 950 950 950
Depth 300 + 23 300 + 23 330 + 30 330 + 30 330 + 30 330 + 30 330 + 30
Height 600 600 943 943 1350 1350 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz /380-415,50Hz 220-240v, 50Hz/380-415,50Hz 220-240v, 50Hz / 380-415,50Hz
PHASE Single Single Single Single Single / 3 Single / 3 Single / 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.12 / 1.07 1.66 / 1.55 1.85 / 1.65 1.90 / 1.94 2.54/2.44 [2.60/2.50] 3.51/3.73[3.57/3.79] 4.43 / 4.65
[3 Phase] Heating/Cooling (UK) 1.00 / 0.91 1.48 / 1.32 1.65 / 1.40 1.69 / 1.65 2.26/2.07 [2.31/2.13] 3.12/3.17 [3.18/3.22] 3.94 / 3.95
STARTING CURRENT (A) 5 5 5 5 5 5 5
SYSTEM RUNNING CURRENT (A) Single Phase 4.37 / 4.23 [13] 6.76 / 6.52 [13] 7.79 / 6.97 [19] 10.17 / 8.55 [19] 13.26 / 13.47 [28] 16.92 / 16.53 [28] 20.92 / 20.72 [29.5]
Heating/Cooling [MAX] 3 Phase - - - - 4.90 / 5.02 [13] 6.14 / 6.04 [13] 7.37 / 7.53 [13]
FUSE RATING (BS88) - HRC (A) 16 16 25 25 32 / 16 32 / 16 40 / 16
MAINS CABLE No. Cores 3 3 3 3 3/5 3/5 3/5
MAX PIPE LENGTH (m) 50 50 50 50 75 75 75
MAX HEIGHT DIFFERENCE (m) 30 30 30 30 30 30 30
CHARGE R410A (kg) - 30m 2.5 2.5 3.5 3.5 5.0 5.0 5.0

Page 84
Mr Slim Range 2008
Dimensions

INDOOR UNIT PLA-RP35-140BA(2)

Upper View >

Lower View >

PLA-RP Power Inverter Heat Pump

Side View >

Models A B
Size 35-71 241 258
Size 100-140 281 298

Page 85
PLA-RP Standard Inverter Heat Pump
4-Way Blow Ceiling Cassette System
The new Standard Inverter range provides inverter solutions for customers
who want all the benefits that inverters offer, but do not have the budget
available for the more expensive Power Inverter range.

I Airflow controllable for ceiling heights up to


4.2m, with automatic adjustment of fan speed
I Reduced draft air distribution,
with independent vane control
I Filter lowering operation down to 4m
(optional PLP-6BAJ grille required)
I Optional ‘I See Sensor’ for energy saving and
smooth temperature control throughout the room

Technical Information
PLA-RP - INDOOR UNITS
MODEL REFERENCE PLA-RP35BA PLA-RP50BA PLA-RP60BA PLA-RP71BA PLA-RP100BA PLA-RP125BA PLA-RP140BA
CAPACITY (kW) Heating (nominal) 4.1 (0.9-5.0) 6.0 (0.9-7.2) 6.9 (0.9-8.0) 8.0 (0.9-10.2) 11.2 (4.5-12.5) 14.0 (5.0-16.0) 16.0 (5.0-18.0)
Cooling (nominal) 3.5 (1.0-3.9) 5.0 (1.1-5.6) 5.7 (1.1-6.3) 7.1 (0.9-8.1) 9.4 (4.9-11.2) 12.3 (5.5-14.0) 13.6 (5.5-15.0)
Heating (UK) 3.4 (0.75-4.15) 5.0 (0.75-6.0) 5.75 (0.75-6.65) 6.65 (0.75-8.5) 9.5 (3.85-10.65) 11.9 (4.25-13.6) 13.6 (4.25-15.3)
Cooling (UK) 3.45 (1.0-3.85) 4.95 (1.1-5.55) 5.65 (1.1-6.25) 7.05 (0.9-8.05) 8.45 (4.4-10.1) 11.05 (4.95-12.6) 12.25 (4.95-13.5)
SHF (nominal) 0.84 0.81 0.76 0.73 0.74 0.71 0.71
COP / EER (nominal) 3.69 / 3.21 3.30 / 2.81 3.27 / 2.94 3.21 / 2.81 3.41 / 3.01 3.41 / 3.01 3.21 / 2.61
ENERGY LABEL Heating/Cooling A /A C/C C/C C/C B/B B/B C/D
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 11-12-13-15 12-14-16-18 12-14-16-18 14-16-18-21 20-23-26-30 22-25-28-31 24-26-29-32
PIPE SIZE mm(in) Gas 9.52 (3/8”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 27-28-29-31 28-29-31-32 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41 36-39-42-44
DIMENSIONS (mm) Width 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
(Grille) Depth 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Height 258 (35) 258 (35) 258 (35) 258 (35) 298 (35) 298 (35) 298 (35)
WEIGHT (kg) Unit 22 22 23 23 25 25 27
Panel 6 6 6 6 6 6 6
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4 4 4
GRILLE REFERENCE PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA
WIRED REMOTE CONTROLLER REFERENCE PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA PAR-21MAA

SUZ-KA / PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE SUZ-KA35VA SUZ-KA50VA SUZ-KA60VA SUZ-KA71VA PUHZ-P100VHA2 PUHZ-P125VHA2 PUHZ-P140VHA2
NOISE (dBA) (Lo-Hi) Heating/Cooling 48 / 47 53-55 / 51-53 53-55 / 51-53 53-55 / 51-53 54 / 50 55 / 51 56 / 52
WEIGHT (kg) 37 53 53 58 75 99 99
DIMENSIONS (mm) Width 800 840 840 840 950 950 950
Depth 285 330 330 330 330 + 30 330 + 30 330 + 30
Height 550 850 850 850 943 1350 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single Single Single
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.11 / 1.09 1.82 / 1.78 2.11 / 1.94 2.49 / 2.53 3.28 / 3.12 4.11 / 4.09 4.98 / 5.21
Heating/Cooling (UK) 1.01 / 0.87 1.62 / 1.42 1.92 / 1.55 2.27 / 2.02 2.92 / 2.65 3.66 / 3.48 4.43 / 4.43
STARTING CURRENT (A) 4.75 6.75 9.75 10.3 4 14 14
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 4.89 / 4.77 [9.18] 6.64 / 7.11 [16] 10.04 / 8.71 [16] 10.33 / 10.81 [16] 13.49 / 13.20 [28] 17.68 / 18.37 [28] 22.31 / 23.55 [29.5]
FUSE RATING (BS88) - HRC (A) 16 25 25 25 32 32 40
MAINS CABLE No. Cores 3 3 3 3 3 3 3
MAX PIPE LENGTH (m) 20 30 30 30 50 50 50
MAX HEIGHT DIFFERENCE (m) 12 30 30 30 30 30 30
CHARGE R410A (kg) 1.05 1.6 1.8 2.0 2.7 4.5 4.5

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Page 86
Mr Slim Range 2008
Dimensions

INDOOR UNIT PLA-RP35-140BA

Upper View >

Lower View >

PLA-RP Standard Inverter Heat Pump

Side View >

Models A B
Size 35-71 241 258
Size 100-140 281 298

Page 87
PLA-RP Heat Pump
4-Way Blow Ceiling Cassette System
The Heat Pump system provides a low cost
alternative to three phase Power Inverter systems.

I Airflow controllable for ceiling heights up to 4.2m,


with automatic adjustment of fan speed
I Reduced draft air distribution, with independent vane control
I Filter lowering operation down to 4m
(optional PLP-6BAJ grille required)
I Optional ‘I See Sensor' for energy saving and smooth
temperature control throughout the room

Technical Information
PLA-RP - INDOOR UNITS
MODEL REFERENCE PLA-RP100BA PLA-RP125BA PLA-RP140BA
CAPACITY (kW) Heating (nominal) 11.5 14.3 17.0
Cooling (nominal) 10.0 12.3 14.2
Heating (UK) 9.8 12.15 14.45
Cooling (UK) 9.0 11.05 12.8
SHF (nominal) 0.74 0.71 0.71
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 20-23-26-30 22-25-28-31 24-26-29-32
PIPE SIZE mm(in) Gas 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 32-34-37-40 34-36-39-41 36-39-42-44
DIMENSIONS (mm) (grille) Width 840 (950) 840 (950) 840 (950)
Depth 840 (950) 840 (950) 840 (950)
Height 298 (35) 298 (35) 298 (35)
WEIGHT (kg) Unit 25 25 27
Panel 6 6 6
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4
GRILLE REFERENCE PLP-6BA PLP-6BA PLP-6BA
WIRED REMOTE CONTROLLER REFERENCE PAR-21MAA PAR-21MAA PAR-21MAA

PUH-P - OUTDOOR UNITS


MODEL REFERENCE PUH-P100YHA PUH-P125YHA PUH-P140YHA
NOISE (dBA) Heating/Cooling 52 / 50 52 / 50 53 / 51
WEIGHT (kg) 94 131 131
DIMENSIONS (mm) Width 950 950 950
Depth 330 + 30 330 + 30 330 + 30
Height 943 1350 1350
ELECTRICAL SUPPLY 380-415,50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 3.40 / 3.53 4.23 / 4.36 5.35 / 5.41
Heating/Cooling (UK) 3.03 / 3.00 3.76 / 3.71 4.76 / 4.60
STARTING CURRENT (A) 45 70 85
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 6.05 / 6.33 [12.2] 7.51 / 7.79 [16.1] 9.45 / 9.62 [19.8]
FUSE RATING (BS88) - HRC (A) 20 20 25
MAINS CABLE No. Cores 5 5 5
MAX PIPE LENGTH (m) 50 50 50
MAX HEIGHT DIFFERENCE (m) 50 50 50
CHARGE R410A (kg) - 30m 4.4 5.0 5.0

Notes: Optional infra-red grille and remote controller available.

Page 88
Mr Slim Range 2008
Dimensions

INDOOR UNIT PLA-RP100-140BA

Upper View >

Lower View >

Side View >


PLA-RP Heat Pump

Models A B
Size 35-71 241 258
Size 100-140 281 298

Page 89
PCA-RP Power Inverter Heat Pump
Ceiling Suspended System
I Indoor unit designed for direct ceiling suspension

I Flush to wall installation for concealment


of service connections

I Electronic control includes learning defrost,


fault finding diagnostics, low ambient
fan speed control and anti-phase/
single phase protection

Technical Information

PCA-RP - INDOOR UNITS


MODEL REFERENCE PCA-RP50GA2 PCA-RP60GA PCA-RP71GA PCA-RP100GA PCA-RP125GA PCA-RP140GA
CAPACITY (kW) Heating (nominal) 6.0 (2.5-7.3) 7.0 (2.8-8.2) 7.6 (3.5-10.2) 11.2 (4.5-14.0) 14.0 (5.0-16.0) 16.0 (5.0-18.0)
Cooling (nominal) 5.0 (2.3-5.6) 6.0 (2.7-6.7) 7.1 (3.3-8.1) 10.0 (4.9-11.4) 12.5 (5.5-14.0) 14.0 (5.5-15.3)
Heating (UK) 5.1 (2.15-6.2) 5.95 (2.4-6.95) 6.45 (3.0-8.65) 9.5 (3.85-11.9) 11.9 (4.25-13.6) 13.6 (4.25-15.3)
Cooling (UK) 4.5 (2.05-5.05) 5.4 (2.45-6.05) 6.4 (2.95-7.3) 9.0 (4.4-10.25) 11.25 (4.95-12.6) 12.6 (4.95-13.75)
SHF (nominal) 0.88 0.86 0.74 0.75 0.77 0.75
COP / EER (nominal) 3.41 / 3.01 3.45 / 3.68 3.41 / 3.32 3.44 / 3.42 3.41 / 3.22 3.48 / 3.01
ENERGY LABEL Heating/Cooling B/B B /A B /A B /A B /A B/B
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 14-15-16-18 14-15-16-18 14-15-16-18 20-21-23-25 27-30-32-34 27-30-32-34
PIPE SIZE mm(in) Gas 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 37-39-41-43 37-39-41-43 37-39-41-43 40-41-43-45 41-43-45-46 42-44-46-48
DIMENSIONS (mm) Width 1310 1310 1310 1310 1620 1620
Depth 680 680 680 680 680 680
Height 210 210 210 270 270 270
WEIGHT (kg) 34 34 34 37 43 45
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP50VHA3 PUHZ-RP60VHA3 PUHZ-RP71VHA3 PUHZ-RP100VHA3/YHA3 PUHZ-RP125VHA2/YHA2 PUHZ-RP140VHA2/YHA2
NOISE (dBA) Heating/Cooling 46 / 44 48 / 47 48 / 47 51 / 49 52 / 50 52 / 50
WEIGHT (kg) 42 68 68 116 / 130 116 / 130 116 / 130
DIMENSIONS (mm) Width 800 950 950 950 950 950
Depth 300 + 23 330 + 30 330 + 30 330 + 30 330 + 30 330 + 30
Height 600 943 943 1350 1350 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz
PHASE Single Single Single Single / 3 Single / 3 Single / 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.76 / 1.66 2.03 / 1.63 2.23 / 2.14 3.26 / 2.92 4.11 / 3.88 4.60 / 4.65
Heating/Cooling (UK) 1.57 / 1.41 1.81 / 1.39 1.98 / 1.82 2.90 / 2.48 3.66 / 3.30 4.09 / 3.95
STARTING CURRENT (A) 5 5 5 5 5 5
SYSTEM RUNNING CURRENT (A) Single Phase 7.0 / 6.69 [13] 8.03 / 7.14 [19] 10.27 / 8.57 [19] 13.08 / 13.22 [28] 16.99 / 16.54 [28] 20.93 / 20.66 [29.5]
Heating/Cooling [MAX] 3 Phase - - - 4.72 / 4.77 [13] 6.21 / 6.05 [13] 7.47 / 7.38 [13]
FUSE RATING (BS88) - HRC (A) 16 25 25 32 / 16 32 / 16 40 / 16
MAINS CABLE No. Cores 3 3 3 3/5 3/5 3/5
MAX PIPE LENGTH (m) 50 50 50 75 75 75
MAX HEIGHT DIFFERENCE (m) 30 30 30 30 30 30
CHARGE R410A (kg) - 30m 2.5 3.5 3.5 5.0 5.0 5.0

Page 90
Mr Slim Range 2008
Dimensions

INDOOR UNIT PCA-RP50-71GA(2)

Lower View > Front View > Side View >

INDOOR UNIT PCA-RP100GA

Lower View > Front View > Side View >

INDOOR UNIT PCA-RP125-140GA

Lower View > Front View > Side View > PCA-RP Power Inverter Heat Pump

Page 91
PCA-RP Standard Inverter Heat Pump
Ceiling Suspended System
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that
inverters offer, but do not have the budget available for the more expensive Power Inverter range.

I Indoor unit designed for direct ceiling suspension

I Flush to wall installation for concealment


of service connections

I Electronic control includes learning defrost,


fault finding diagnostics, low ambient fan speed
control and anti-phase / single phase protection

Technical Information
PCA-RP - INDOOR UNITS
MODEL REFERENCE PCA-RP50GA2 PCA-RP60GA PCA-RP71GA PCA-RP100GA PCA-RP125GA PCA-RP140GA

CAPACITY (kW) Heating (nominal) 6.0 (0.9-7.2) 6.9 (0.9-8.0) 8.0 (0.9-10.2) 11.2 (4.5-12.5) 14.0 (5.0-16.0) 16.0 (5.0-18.0)
Cooling (nominal) 5.0 (1.1-5.6) 5.5 (1.1-6.3) 7.1 (0.9-8.1) 9.4 (4.9-11.2) 12.3 (5.5-14.0) 13.6 (5.5-15.0)
Heating (UK) 5.0 (0.75-6.0) 5.75 (0.75-6.65) 6.65 (0.75-8.5) 9.5 (3.85-10.65) 11.9 (4.25-13.6) 13.6 (4.25-15.3)
Cooling (UK) 4.95 (1.1-5.55) 5.45 (1.1-6.25) 7.05 (0.9-8.05) 8.45 (4.4-10.1) 11.05 (4.95-12.6) 12.25 (4.95-13.5)
SHF (nominal) 0.81 0.79 0.71 0.77 0.78 0.76
COP / EER (nominal) 3.41 / 2.81 3.37 / 2.86 3.21 / 2.81 3.21 / 2.81 2.81 / 2.81 3.21 / 2.61
ENERGY LABEL Heating/Cooling B/C C/C C/C C/C D/C C/D
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 14-15-16-18 14-15-16-18 14-15-16-18 20-21-23-25 27-30-32-34 27-30-32-34
PIPE SIZE mm(in) Gas 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 37-39-41-43 37-39-41-43 37-39-41-43 40-41-43-45 41-43-45-46 42-44-46-48
DIMENSIONS (mm) Width 1310 1310 1310 1310 1620 1620
Depth 680 680 680 680 680 680
Height 210 210 210 270 270 270
WEIGHT (kg) 34 34 34 37 43 45
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4 4 4 4

SUZ-KA / PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE SUZ-KA50VA SUZ-KA60VA SUZ-KA71VA PUHZ-P100VHA2 PUHZ-P125VHA2 PUHZ-P140VHA2
NOISE (dBA) (Lo-Hi) Heating/Cooling 53-55 / 51-53 53-55 / 51-53 53-55 / 51-53 54 / 50 55 / 51 56 / 52
WEIGHT (kg) 53 53 58 75 99 99
DIMENSIONS (mm) Width 840 840 840 950 950 950
Depth 330 330 330 330 + 30 330 + 30 330 + 30
Height 850 850 850 943 1350 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single Single
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 1.76 / 1.78 2.05 / 1.92 2.49 / 2.53 3.49 / 3.35 4.98 / 4.38 4.98 / 5.21
Heating/Cooling (UK) 1.60 / 1.42 1.87 / 1.54 2.27 / 2.02 3.11 / 2.85 4.43 / 3.72 4.43 / 4.43
STARTING CURRENT (A) 6.75 9.75 10.3 4 14 14
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 6.88 / 7.28 [16] 10.28 / 8.88 [16] 10.43 / 10.83 [16] 13.31 / 12.95 [28] 17.75 / 18.38 [28] 22.32 / 23.49 [29.5]
FUSE RATING (BS88) - HRC (A) 25 25 25 32 32 40
MAINS CABLE No. Cores 3 3 3 3 3 3
MAX PIPE LENGTH (m) 30 30 30 50 50 50
MAX HEIGHT DIFFERENCE (m) 30 30 30 30 30 30
CHARGE R410A (kg) 1.6 1.8 2.0 2.7 4.5 4.5

Notes: All units charged to 7m (50-71), 20m (100) and 30m (125-140) pipe length.

Page 92
Mr Slim Range 2008
Dimensions

INDOOR UNIT PCA-RP50-71GA(2)

Lower View > Front View > Side View >

INDOOR UNIT PCA-RP100GA

Lower View > Front View > Side View >

INDOOR UNIT PCA-RP125-140GA


PCA-RP Standard Inverter Heat Pump
Lower View > Front View > Side View >

Page 93
PCA-RP Heat Pump
Ceiling Suspended System
The Heat Pump system provides a low cost alternative
to three phase Power Inverter systems.

I Indoor unit designed for direct ceiling suspension

I Flush to wall installation for concealment of service connections

I Electronic control includes learning defrost, fault finding


diagnostics, low ambient fan speed control and
anti-phase / single phase protection

Technical Information

PCA-RP - INDOOR UNITS


MODEL REFERENCE PCA-RP100GA PCA-RP125GA PCA-RP140GA
CAPACITY (kW) Heating (nominal) 11.5 14.3 17.0
Cooling (nominal) 9.8 12.3 14.2
Heating (UK) 9.8 12.15 14.45
Cooling (UK) 8.8 11.05 12.8
SHF (nominal) 0.75 0.77 0.75
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 20-21-23-25 27-30-32-34 27-30-32-34
PIPE SIZE mm(in) Gas 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Mi1-Mi2-Hi 40-41-43-45 41-43-45-46 42-44-46-48
DIMENSIONS (mm) Width 1310 1620 1620
Depth 680 680 680
Height 270 270 270
WEIGHT (kg) 37 43 45
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single Single
FUSE RATING (BS88) - HRC (A) 6 6 6
INTERCONNECTING CABLE No. CORES 4 4 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE PUH-P100YHA PUH-P125YHA PUH-P140YHA
NOISE (dBA) Heating/Cooling 52 / 50 52 / 50 53 / 51
WEIGHT (kg) 94 131 131
DIMENSIONS (mm) Width 950 950 950
Depth 330 + 30 330 + 30 330 + 30
Height 943 1350 1350
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) 3.45 / 3.55 4.72 / 4.52 5.22 / 5.44
Heating/Cooling (UK) 3.07 / 3.02 4.20 / 3.84 4.65 / 4.62
STARTING CURRENT (A) 45 70 85
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 5.87 / 6.08 [12.0] 7.58 / 7.8 [16.2] 9.46 / 9.56 [19.8]
FUSE RATING (BS88) - HRC (A) 20 20 25
MAINS CABLE No. Cores 5 5 5
MAX PIPE LENGTH (m) 50 50 50
MAX HEIGHT DIFFERENCE (m) 50 50 50
CHARGE R410A (kg) - 30m 4.4 5.0 5.0

Page 94
Mr Slim Range 2008
Dimensions

INDOOR UNIT PCA-RP100GA

Front View > Side View >

Lower View >

INDOOR UNIT PCA-RP125-140GA

Front View > Side View >

Lower View >


PCA-RP Heat Pump

Page 95
PCA-RP-HA Power Inverter Heat Pump
Stainless Steel Ceiling Suspended System
The PCA-RP-HA series is a ceiling suspended unit ideal for
use in kitchen environments. The external casing is made
of durable stainless steel that is resistant to oil and smoke,
ensuring that the unit can be easily cleaned at all times.

I High performance oil mist filter


I Easy maintenance - fan casing can be separated into
different sections allowing easy cleaning. The drain
pan can also be cleaned easily on-site as the pipe
connector can be quickly removed
I Optional decoration covers

Technical Information

PCA-RP-HA - INDOOR UNITS


MODEL REFERENCE PCA-RP71HA PCA-RP125HA
CAPACITY (kW) Heating (nominal) 7.6 (3.5-10.2) 13.8 (5.0-16.0)
Cooling (nominal) 7.1 (3.3-8.1) 12.5 (5.5-14.0)
Heating (UK) 6.45 (3.0-8.65) 11.75 (4.25-13.6)
Cooling (UK) 6.4 (2.95-7.3) 11.25 (4.95-12.6)
SHF (nominal) 0.74 0.77
COP / EER (nominal) 3.41 / 3.21 3.41 / 3.22
ENERGY LABEL Heating/Cooling B /A B /A
AIRFLOW (m3/min) Lo-Hi 17-19 30-38
PIPE SIZE mm(in) Gas 15.88 (5/8”) 15.88 (5/8”)
Liquid 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Hi 34-38 44-50
DIMENSIONS (mm) Width 1136 1520
Depth 650 650
Height 280 280
WEIGHT (kg) 41 56
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single
FUSE RATING (BS88) - HRC (A) 6 6
INTERCONNECTING CABLE No. CORES 4 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP71VHA3 PUHZ-RP125VHA2/YHA2
NOISE (dBA) Heating/cooling 48 / 47 52 / 50
WEIGHT (kg) 68 116 / 130
DIMENSIONS (mm) Width 950 950
Depth 330 + 30 330 + 30
Height 943 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz / 380-415v, 50Hz
PHASE Single Single / 3
SYSTEM POWER INPUT (KW) Heating/Cooling (nominal) 2.23 / 2.21 4.05 / 3.88
Heating/Cooling (UK) 1.98 / 1.88 3.60 / 3.30
STARTING CURRENT (A) 5 5
SYSTEM RUNNING CURRENT (A) Single Phase 10.17 / 8.47 [19] 17.17 / 16.72 [28]
Heating/Cooling [MAX] 3 Phase - 6.39 / 6.23 [13]
FUSE RATING (BS88) - HRC (A) 25 32 / 16
MAINS CABLE No. Cores 3 3/5
MAX PIPE LENGTH (m) 50 75
MAX HEIGHT DIFFERENCE (m) 30 30
CHARGE R410A (kg) - 30m 3.5 5.0

Page 96
Mr Slim Range 2008
Dimensions

INDOOR UNIT PCA-RP71HA

Front View >


1224
1180

110 102
986 75
1136

Lower View >

Side View >


650

258

280

1136 650

INDOOR UNIT PCA-RP125HA

Front View >


1608
1564

PCA-RP-HA Power Inverter Heat Pump


110 102

1370 75
1520

Lower View >

Side View >


650

280
258

1520 650

Page 97
PCA-RP-HA Standard Inverter Heat Pump
Stainless Steel Ceiling Suspended System
The new Standard Inverter range provides inverter solutions
for customers who want all the benefits that inverters offer,
but do not have the budget available for the more
expensive Power Inverter range.

I High performance oil mist filter


I Easy maintenance - fan casing can be separated into
different sections allowing easy cleaning. The drain
pan can also be cleaned easily on-site as the pipe
connector can be quickly removed
I Optional decoration covers

Technical Information
PCA-RP-HA - INDOOR UNITS
MODEL REFERENCE PCA-RP125HA
CAPACITY (kW) Heating (nominal) 13.8 (5.0-16.0)
Cooling (nominal) 12.3 (5.5-14.0)
Heating (UK) 11.75 (4.25-13.6)
Cooling (UK) 11.05 (4.95-12.6)
SHF (nominal) 0.78
COP / EER (nominal) 3.21 / 2.81
ENERGY LABEL Heating/Cooling C/C
AIRFLOW (m3/min) Lo-Hi 30-38
PIPE SIZE mm(in) Gas 15.88 (5/8”)
Liquid 9.52 (3/8”)
NOISE (dBA) Lo-Hi 44-50
DIMENSIONS (mm) Width 1520
Depth 650
Height 280
WEIGHT (kg) 56
ELECTRICAL SUPPLY Fed by Outdoor Unit
PHASE Single
FUSE RATING (BS88) - HRC (A) 6
INTERCONNECTING CABLE No. CORES 4

PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE PUHZ-P125VHA2
NOISE (dBA) Heating/cooling 55 / 51
WEIGHT (kg) 99
DIMENSIONS (mm) Width 950
Depth 330 + 30
Height 1350
ELECTRICAL SUPPLY 220-240v, 50Hz
PHASE Single
SYSTEM POWER INPUT (KW) Heating/Cooling (nominal) 4.30 / 4.38
Heating/Cooling (UK) 3.83 / 3.72
STARTING CURRENT (A) 14
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 17.93 / 18.56 [28]
FUSE RATING (BS88) - HRC (A) 32
MAINS CABLE No. Cores 3
MAX PIPE LENGTH (m) 50
MAX HEIGHT DIFFERENCE (m) 30
CHARGE R410A (kg) - 30m 4.5

Page 98
Mr Slim Range 2008
Dimensions

INDOOR UNIT PCA-RP125HA

Front View >


1608
1564

110 102
1370 75
1520

Lower View >

Side View >


650

280
258

1520 650

PCA-RP-HA Standard Inverter Heat Pump

Page 99
PCA-RP-HA Heat Pump
Stainless Steel Ceiling Suspended System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

The PCA-RP-HA series is a ceiling suspended unit ideal for


use in kitchen environments. The external casing is made of
durable stainless steel that is resistant to oil and smoke,
ensuring that the unit can be easily cleaned at all times.

I High performance oil mist filter

I Easy maintenance - fan casing can be separated into


different sections allowing easy cleaning. The drain pan
can also be cleaned easily on-site as the pipe
connector can be quickly removed

I Optional decoration covers

Technical Information
PCA-RP-HA - INDOOR UNITS
MODEL REFERENCE PCA-RP125HA
CAPACITY (kW) Heating (nominal) 14.3
Cooling (nominal) 12.3
Heating (UK) 12.2
Cooling (UK) 11.05
SHF (nominal) 0.77
AIRFLOW (m3/min) Lo-Hi 30-38
PIPE SIZE mm(in) Gas 15.88 (5/8”)
Liquid 9.52 (3/8”)
NOISE (dBA) Lo-Hi 44-50
DIMENSIONS (mm) Width 1520
Depth 650
Height 280
WEIGHT (kg) 56
ELECTRICAL SUPPLY Fed by Outdoor Unit
PHASE Single
FUSE RATING (BS88) - HRC (A) 6
INTERCONNECTING CABLE No. CORES 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE PUH-P125YHA
NOISE (dBA) Heating/cooling 52 / 50
WEIGHT (kg) 131
DIMENSIONS (mm) Width 950
Depth 330 + 30
Height 1350
ELECTRICAL SUPPLY 380-415v, 50Hz
PHASE 3
SYSTEM POWER INPUT (KW) Heating/Cooling (nominal) 5.01 / 4.55
Heating/Cooling (UK) 4.46 / 3.87
STARTING CURRENT (A) 70
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 7.76 / 7.98 [16.3]
FUSE RATING (BS88) - HRC (A) 20
MAINS CABLE No. Cores 5
MAX PIPE LENGTH (m) 50
MAX HEIGHT DIFFERENCE (m) 50
CHARGE R410A (kg) - 30m 5.0

Page 100
Mr Slim Range 2008
Dimensions

INDOOR UNIT PCA-RP125HA

Front View >


1608
1564

110 102
1370 75
1520

Lower View >

Side View >


650

280
258

1520 650

PCA-RP-HA Heat Pump

Page 101
PSA-RP Power Inverter Heat Pump
Floor Standing System
The PSA-RP Floor Standing System compliments the Mitsubishi
Electric range of indoor units. The sleek, modern design of this unit
is ideal for numerous applications including bars and restaurants.

I Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.
Technical Information
PSA-RP - INDOOR UNITS
MODEL REFERENCE PSA-RP71GA PSA-RP125GA
CAPACITY (kW) Heating (nominal) 7.6 (3.5-10.2) 14.0 (5.0-16.0)
Cooling (nominal) 7.1 (3.3-8.1) 12.4 (5.5-14.0)
Heating (UK) 6.45 (3.0-8.65) 11.9 (4.25-13.6)
Cooling (UK) 6.4 (2.95-7.3) 11.15 (4.95-12.6)
SHF (nominal) 0.73 0.75
COP / EER (nominal) 3.41 / 3.23 3.41 / 3.01
ENERGY LABEL Heating/Cooling B /A B/B
AIRFLOW (m3/min) Lo-Hi 15-18 26-33
PIPE SIZE mm(in) Gas 15.88 (5/8”) 15.88 (5/8”)
Liquid 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Lo-Hi 40-45 46-51
DIMENSIONS (mm) Width 600 600
Depth 270 350
Height 1900 1900
WEIGHT (kg) 43 51
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit
PHASE Single Single
FUSE RATING (BS88) - HRC (A) 6 6
INTERCONNECTING CABLE No. CORES 4 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP71VHA3 PUHZ-RP125VHA2/YHA2
NOISE (dBA) Heating/cooling 48 / 47 52 / 50
WEIGHT (kg) 68 116 / 130
DIMENSIONS (mm) Width 950 950
Depth 330 + 30 330 + 30
Height 943 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz / 380-415v, 50Hz
PHASE Single Single / 3
SYSTEM POWER INPUT (KW) Heating/Cooling (nominal) 2.23 / 2.20 4.11 / 4.12
Heating/Cooling (UK) 1.98 / 1.87 3.66 / 3.50
STARTING CURRENT (A) 5 5
SYSTEM RUNNING CURRENT (A) Single Phase 10.4 / 8.7 [19] 17.21 / 16.76 [28]
Heating/Cooling [MAX] 3 Phase - 6.43 / 6.27 [13]
FUSE RATING (BS88) - HRC (A) 25 32 / 16
MAINS CABLE No. Cores 3 3 / 5
MAX PIPE LENGTH (m) 50 75
MAX HEIGHT DIFFERENCE (m) 30 30
CHARGE R410A (kg) - 30m 3.5 5.0

Page 102
Mr Slim Range 2008
Dimensions

INDOOR UNIT PSA-RP71GA

Front View > Side View > Upper View >

INDOOR UNIT PSA-RP125GA

Front View > Side View > Upper View >

PSA-RP Power Inverter Heat Pump

Page 103
PSA-RP Standard Inverter Heat Pump
Floor Standing System
The Standard Inverter range provides inverter solutions for customers
who want all the benefits that inverters offer, but do not have the budget
available for the more expensive Power Inverter range.
The PSA-RP Floor Standing System compliments the Mitsubishi Electric
range of indoor units. The sleek, modern design of this unit is ideal
for numerous applications including bars and restaurants.

I Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.
Technical Information
PSA-RP - INDOOR UNITS
MODEL REFERENCE PSA-RP125GA
CAPACITY (kW) Heating (nominal) 14.0 (5.0-16.0)
Cooling (nominal) 12.3 (5.5-14.0)
Heating (UK) 11.9 (4.25-13.6)
Cooling (UK) 11.05 (4.95-12.6)
SHF (nominal) 0.76
COP / EER (nominal) 2.81 / 2.81
ENERGY LABEL Heating/Cooling D/C
AIRFLOW (m3/min) Lo-Hi 26-33
PIPE SIZE mm(in) Gas 15.88 (5/8”)
Liquid 9.52 (3/8”)
NOISE (dBA) Lo-Hi 46-51
DIMENSIONS (mm) Width 600
Depth 350
Height 1900
WEIGHT (kg) 51
ELECTRICAL SUPPLY Fed by Outdoor Unit
PHASE Single
FUSE RATING (BS88) - HRC (A) 6
INTERCONNECTING CABLE No. CORES 4

PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE PUHZ-P125VHA2
NOISE (dBA) Heating/cooling 55 / 51
WEIGHT (kg) 99
DIMENSIONS (mm) Width 950
Depth 330 + 30
Height 1350
ELECTRICAL SUPPLY 220-240v, 50Hz
PHASE Single
SYSTEM POWER INPUT (KW) Heating/Cooling (nominal) 4.98 / 4.38
Heating/Cooling (UK) 4.43 / 3.72
STARTING CURRENT (A) 14
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 17.97 / 18.6 [28]
FUSE RATING (BS88) - HRC (A) 32
MAINS CABLE No. Cores 3
MAX PIPE LENGTH (m) 50
MAX HEIGHT DIFFERENCE (m) 30
CHARGE R410A (kg) - 30m 4.5

Page 104
Mr Slim Range 2008
Dimensions

INDOOR UNIT PSA-RP125GA

Front View > Side View > Upper View >

PSA-RP Standard Inverter Heat Pump

Page 105
PSA-RP Heat Pump
Floor Standing System
The Heat Pump system provides a low cost alternative to
three phase Power Inverter systems.
The PSA-RP Floor Standing System compliments the Mitsubishi Electric
range of indoor units. The sleek, modern design of this unit is ideal
for numerous applications including bars and restaurants.

I Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.
Technical Information

PSA-RP - INDOOR UNITS


MODEL REFERENCE PSA-RP125GA
CAPACITY (kW) Heating (nominal) 14.3
Cooling (nominal) 12.3
Heating (UK) 12.2
Cooling (UK) 11.05
SHF (nominal) 0.75
AIRFLOW (m3/min) Lo-Hi 26-33
PIPE SIZE mm(in) Gas 15.88 (5/8”)
Liquid 9.52 (3/8”)
NOISE (dBA) Lo-Hi 46-51
DIMENSIONS (mm) Width 600
Depth 350
Height 1900
WEIGHT (kg) 51
ELECTRICAL SUPPLY Fed by Outdoor Unit
PHASE Single
FUSE RATING (BS88) - HRC (A) 6
INTERCONNECTING CABLE No. CORES 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE PUH-P125YHA
NOISE (dBA) Heating/cooling 52 / 50
WEIGHT (kg) 131
DIMENSIONS (mm) Width 950
Depth 330 + 30
Height 1350
ELECTRICAL SUPPLY 380-415v, 50Hz
PHASE 3
SYSTEM POWER INPUT (KW) Heating/Cooling (nominal) 4.41 / 4.54
Heating/Cooling (UK) 3.92 / 3.86
STARTING CURRENT (A) 70
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling 7.8 / 8.02 [16.4]
FUSE RATING (BS88) - HRC (A) 20
MAINS CABLE No. Cores 5
MAX PIPE LENGTH (m) 50
MAX HEIGHT DIFFERENCE (m) 50
CHARGE R410A (kg) - 30m 5.0

Page 106
Mr Slim Range 2008
Dimensions

INDOOR UNIT PSA-RP125GA

Front View > Side View > Upper View >

PSA-RP Heat Pump

Page 107
PHV DXE Heat Pump Air Curtain
Heat Pump Air Curtain System
In collaboration with Thermoscreens, Mitsubishi Electric have developed a range of air cur tains that are able to
be connected to our Power Inver ter heat pumps, as opposed to the more traditional direct electric method
associated with air cur tains.
I Reduced CO2 emissions (up to 67%)
I Reduced Running Costs (up to 67%)
I 2.5 year payback period against equivalent Electric system
I Inverter technology (does not waste energy)
I Range of different sizes to suit every application
I Allows open door policy in retail outlets
whilst being energy efficient
I Clean environment - protection from dust, fumes etc
I Comfortable climate for customers
I Easy to install and maintain

Technical Information

PHV DXE - RECESSED


MODEL REFERENCE PHV1500R DXE HO PHV2000R DXE LO PHV2000R DXE HO
DIMENSIONS (mm) (WxDxH) 1650x436x296 2240x436x296 2240x436x296
SUPPLY (50Hz) 415V*1 415V*2 415V*2
HEAT OUTPUT (kW) 100% / 50% 14.4 / 8.3 14.1 / 7.9 21.3 / 11.2
COP 100% / 50% 2.5 / 3.7 2.9 / 3.7 2.4 / 3.2
LOADING (amps) 12.7*1 15.7*2 15.7*2
VELOCITY (m/s) 9 9.5 9
AIR VOLUME (m3/h) 2600 3300 3130
WEIGHT (kg) 67 85 88
dB(A) @ 3m 100% / 50% 60 / 58 61 / 59 61 / 59
MAX. MOUNTING HEIGHT (m) 3.5 3.5 3.5
OUTDOOR UNIT MODEL PUHZ-RP140VHA2/YHA2 PUHZ-RP100VHA3/YHA3 PUHZ-RP200YHA2
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

PHV DXE - FREE STANDING


MODEL REFERENCE PHV1500 DXE HO PHV2000 DXE LO PHV2000 DXE HO
DIMENSIONS (mm) (WxDxH) 1746x377x255 2296x377x255 2296x377x255
SUPPLY (50Hz) 415V*1 415V*2 415V*2
HEAT OUTPUT (kW) 100% / 50% 14.4 / 8.3 14.1 / 7.9 21.3 / 11.2
COP 100% / 50% 2.5 / 3.7 2.9 / 3.7 2.4 / 3.2
LOADING (amps) 12.7*1 15.7*2 15.7*2
VELOCITY (m/s) 9 9.5 9.5
AIR VOLUME (m3/h) 2600 3300 3130
WEIGHT (kg) 60 78 80
dB(A) @ 3m 100% / 50% 60 / 58 61 / 59 61 / 59
MAX. MOUNTING HEIGHT (m) 3.75 3.75 3.75
OUTDOOR UNIT MODEL PUHZ-RP140VHA2/YHA2 PUHZ-RP100VHA3/YHA3 PUHZ-RP200YHA2
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

HEAT PUMP OUTDOOR UNITS


MODEL REFERENCE PUHZ-RP100VHA3/YHA3 PUHZ-RP140VHA2/YHA2 PUHZ-RP200YHA2
DIMENSIONS (mm) (WxDxH) 950x330+30x1350 950x330+30x1350 950x330+30x1350
SUPPLY (50Hz) 230V / 415V 230V / 415V 415V
MAX. CURRENT (A) 28 / 13 29.5 / 13 19
FUSE SIZE HRC (BS88) 32 / 16 40 / 16 25
MAX. PIPE RUN Length (m) 50 50 100
Height (m) 30 30 30
PIPE SIZES Gas mm(in) 15.88 (5/8) 15.88 (5/8) 28.58 (1 1/8)
Liquid mm(in) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
INTERCONNECTING CABLE 2 core 2 core 2 core

Page 108
Mr Slim Range 2008
Dimensions

AIR CURTAIN PHV1500/2000R DXE


Side View > Rear View >

Upper View >

AIR CURTAIN PHV1500/2000 DXE

Side View > Rear View >

Upper View >


PHV DXE Air Curtain

Page 109
Mr Slim Multi-Split Systems
Heat Pump
The multi-split system is an ideal option for open plan spaces in medium sized premises such as offices or shops, where two,
three or four units are required. These can be Mr Slim ceiling cassettes (PLA-RP), ceiling suspended (PCA-RP), ducted
(PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP) models and can be connected to a single outdoor unit using
twin, triple or quadruple multi distributor pipes.
I Twin, triple or quadruple indoor heat pump units can be operated in
Multi-Split configuration from a single outdoor unit
I Heat pumps must operate in same heating or cooling mode
I Cooling capacity range 3.3 to 28kW
I Heating capacity range 3.5 to 31.5kW

Note: SEZ or SLZ units cannot be used as part of a Mr Slim Multi-Split system.
PSA-RP cannot be connected with indoor units of different type.
Technical Information

PIPE RUN PARAMETERS


Outdoor Model Pipe Runs Max. Pipe Run (m)
PUH-P100-140YHA A+B+C twin 50
PUH-P100-140YHA A+B+C+D triple 50
PUH-P100-140YHA B – C or C – D or B – D ≥8
PUHZ-P100-140VHA2 A+B+C twin 50
PUHZ-P200/250YHA A+B+C twin 70
PUHZ-RP71VHA3 A+B+C twin 50
PUHZ-RP100-140V/YHA2/3 A+B+C twin 75
PUHZ-RP200/250YHA2 A+B+C twin 80 (120)
PUHZ-P140VHA2 A+B+C+D triple 50
PUHZ-P200/250YHA A+B+C+D triple 70
PUHZ-RP140V/YHA2 A+B+C+D triple 75
PUHZ-RP200/250YHA2 A+B+C+D triple 80 (120)
PUHZ-P200/250YHA A+B+C+D+E quadruple 70
PUHZ-RP200/250YHA2 A+B+C+D+E quadruple 80 (120)
PUHZ-P100-140VHA2 B – C or C – D or B – D ≥8
PUHZ-RP71-140V/YHA2/3 B – C or C – D or B – D ≥8
PUHZ-P200/250YHA B - C or B - D or B - E or C - D or C - E or D - E ≥8
PUHZ-RP200/250YHA2 B - C or B - D or B - E or C - D or C - E or D - E ≥8
H = 30m. h = 1m. Note: H for the PUHZ-RP200/250YHA2 = 40m

TWIN TRIPLE QUADRUPLE

Indoor Units Indoor


B Units B C Indoor Units
D
B
h h h
C h
C
Multi distributor D
Pipes Outdoor Units E
Outdoor Units
Multi distributor
Pipes Outdoor
A A Units
A
Multi distributor H
H Pipes H

Page 110
Mr Slim Range 2008
Technical Information

Multi-Split Systems - Combinations Table


Indoor Unit Outdoor No. of Indoor Total Heating Total Cooling Pipe Kit
Heat Pump Units Capacity (kW) Capacity (kW) Part Number

Size 35 PUHZ-RP71 2 3.5 - 10.2 3.3 - 8.1 MSDD-50SR-E

Size 50 PUH-P100 2 11.5 10.0 MSDD-50SR-E

Size 50 PUHZ-P100 2 4.5 - 12.5 4.9 - 11.2 MSDD-50SR-E

Size 50 PUHZ-RP100 2 4.5 - 14.0 4.9 - 11.4 MSDD-50SR-E

Size 60 PUH-P125 2 14.3 12.3 MSDD-50SR-E

Size 60 PUHZ-P125 2 5.0 - 16.0 5.5 - 14.0 MSDD-50SR-E

Size 60 PUHZ-RP125 2 5.0 - 16.0 5.5 - 14.0 MSDD-50SR-E

Size 71 PUH-P140 2 17.0 14.2 MSDD-50SR-E

Size 71 PUHZ-P140 2 5.0 - 18.0 5.5 - 15.0 MSDD-50SR-E

Size 71 PUHZ-RP140 2 5.0 - 18.0 5.5 - 15.3 MSDD-50SR-E

Size 50 PUH-P140 3 17.0 14.2 MSDT-111R-E

Size 50 PUHZ-P140 3 5.0 - 18.0 5.5 - 15.0 MSDT-111R-E

Size 50 PUHZ-RP140 3 5.0 - 18.0 5.5 - 15.3 MSDT-111R-E

Size 100 PUHZ-P200 2 9.5 - 25.0 9.0 - 22.4 MSDD-50WR-E

Size 60 PUHZ-P200 3 9.5 - 25.0 9.0 - 22.4 MSDT-111R-E

Size 50 PUHZ-P200 4 9.5 - 25.0 9.0 - 22.4 MSDF-1111R-E

Size 100 PUHZ-RP200 2 9.5 - 25.0 9.0 - 22.4 MSDD-50WR-E

Size 60 PUHZ-RP200 3 9.5 - 25.0 9.0 - 22.4 MSDT-111R-E

Size 50 PUHZ-RP200 4 9.5 - 25.0 9.0 - 22.4 MSDF-1111R-E

Size 125 PUHZ-P250 2 12.5 - 31.5 11.2 - 28.0 MSDD-50WR-E

Size 71 PUHZ-P250 3 12.5 - 31.5 11.2 - 28.0 MSDT-111R-E

Size 60 PUHZ-P250 4 12.5 - 31.5 11.2 - 28.0 MSDF-1111R-E

Size 125 PUHZ-RP250 2 12.5 - 31.5 11.2 - 28.0 MSDD-50WR-E

Size 71 PUHZ-RP250 3 12.5 - 31.5 11.2 - 28.0 MSDT-111R-E

Size 60 PUHZ-RP250 4 12.5 - 31.5 11.2 - 28.0 MSDF-1111R-E


Multi-Split Systems

Page 111
Outdoor Units
SUZ-KA25/35VA

Upper View >

Side View >


Front View >

SUZ-KA50/60/71VA

Upper View >

Front View > Side View >

Dimensions

Page 112
Mr Slim Range 2008
Dimensions

PUHZ-RP35/50VHA3

Upper View >

Front View > Right Side View >

PUHZ-RP60/71VHA3 / PUHZ-P100VHA2 / PUH-P100YHA

Upper View >

Rear View > Left Side View > Front View > Right Side View >
Outdoor Unit Dimensions

Page 113
Outdoor Units
PUHZ-RP100VHA3/YHA3 / PUHZ-RP125-250VHA2 / PUHZ-P125/140VHA2
PUHZ-P200/250YHA / PUH-P125/140YHA

Upper View >

Rear View > Left Side View > Front View > Right Side View >

Dimensions

Page 114
Mr Slim Range 2008
PAC-IF011B-E
Air Handling Unit Controller
The Air Handling Unit Controllers are an interface to allow connection
to third party manufacturer equipment.

Mitsubishi Electric Mr Slim outdoor units can be used with


this interface box, creating an ideal solution when a
unique air handling unit is required.

I No need for expansion device


I Error, operation and defrost output
I Demand control by analogue or digital inputs
(0-10Ω, 4-20mA, 1-5V, 0-10V, Step, Auto-Step)

Technical Information

PAC-IF011B-E
MITSUBISHI ELECTRIC OUTDOOOR UNIT SIZE 35 SIZE 50 SIZE 60 SIZE 71 SIZE 100 SIZE 125 SIZE 140 SIZE 200 SIZE 250
CAPACITY (kW) Heating (nominal) 4.1 6.0 7.0 7.6 11.2 14.0 16.0 22.4 27.0
Cooling (nominal) 3.5 5.0 6.0 7.1 10.0 12.5 14.0 19.0 22.0
AUTO STEP PUHZ-RP VHA3 VHA3 VHA3 VHA3 V/YHA3 V/YHA2 V/YHA2 YHA2 YHA2
PUHZ-P - - - - VHA2 VHA2 VHA2 YHA YHA
SUZ-KA VA VA VA VA - - - - -
PUH-P - - - - YHA YHA YHA - -
MANUAL STEP PUHZ-RP VHA3 VHA3 VHA3 VHA3 V/YHA3 V/YHA2 V/YHA2 YHA2 YHA2
PIPE SIZE (mm) PUHZ-(R)P 12.7 / 6.35 12.7 / 6.35 15.88 / 9.52 15.88 / 9.52 15.88 / 9.52 15.88 / 9.52 15.88 / 9.52 28.58 / 9.52 28.58 / 12.7
SUZ-KA 9.52 / 6.35 12.7 / 6.35 15.88 / 6.35 15.88 / 9.52 - - - - -
Gas / Liquid PUH-P - - - - 15.88 / 9.52 15.88 / 9.52 15.88 / 9.52 - -
HEAT EXCHANGER Max Capacity 1050 1500 1800 2130 3000 3750 4200 6000 7500
VOLUME (cm3) Min Capacity 350 500 600 710 1000 1250 1400 2000 2500
DIMENSIONS (mm) Width 336 336 336 336 336 336 336 336 336
Depth 69 69 69 69 69 69 69 69 69
Height 278 278 278 278 278 278 278 278 278
WEIGHT (kg) 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5

Note: One air handling unit controller is required per air handling unit
Cooling: Indoor 27ºC DB/19ºC WB, Outdoor 35ºC DB/24ºC WB
Heating: Indoor 20ºC DB, Outdoor 7ºC DB/6ºC WB

Example: Air Handling Unit Controller Controller (field supplied)


Air Handling Unit Controller

(Mitsubishi Electric)
Outdoor Unit Dimensions /

A Control wiring Thermistor wiring

Piping

Outdoor Unit (Mitsubishi Electric) Air Handling Unit (field supplied)

Page 115
Mr Slim Range 2008
Accessories / Optional Extras
M Series

Wall Mounted Units S70 515 716 - Terminal block


S71 000 028 - CN22 connector

Ceiling Concealed Ducted Units PAC-SK005MT-F - 130Pa fan motor PEAD-RP71EA


PAC-SK004MT-F - 130Pa fan motor PEAD-RP100EA2
PAC-SK003MT-F - 130Pa fan motor PEAD-RP125/140EA
PAC-KE03DM-G - Optional drain lift pump PEAD-RP35-140EA(2)
MAC-399IF - Interface for connection to M-NET System SEZ-KD25-71VA
MAC-397IF - Interface for group control and run/fault SEZ-KD25-71VA

4-Way Blow Cassette Units PAC-SH53TM-E - Multi function casement PLA-RP35-140BA(2) for fresh air 100mm knockout or
to hold the high efficiency filter option
PAC-SH59KF-E - High efficiency filter PLA-RP35-140BA(2)
PLP-6BALM - Grille and infra-red controller PLA-RP35-140BA(2)
PLP-6BAJ - Grille with filter lowering function PLA-RP35-140BA(2)
PAC-SA1ME-E - ‘I-See Sensor’ corner panel PLA-RP35-140BA(2)
PAR-SA9FA-E - Infra-red signal receiver PLA-RP35-140BA(2)
S70E40714 - Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2)
MAC-399IF - Interface for connection to M-NET System SLZ-KA25-50VA
MAC-397IF - Interface for group control and run/fault SLZ-KA25-50VA

Ceiling Suspended Units PAR-SL99B-E - Wireless remote controller and adaptor


PAC-SE85DMA-E - Optional drain lift pump PCA-RP50-71GA(2)
PAC-SE86DMA-E - Optional drain lift pump PCA-RP100-140GA
PAC-SG38KF-E - Oil mist filter for PCA-RP71/125HA (12 pack)
PAC-SF81KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP71HA
PAC-SF82KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP125HA

Outdoor Units PAC-SG61DS-E - Drain socket set PUHZ-RP35-250V/YHA2/3 / PUHZ-P100-250VHA2/YHA


PAC-SG58SG-E - Air outlet guide PUHZ-RP35-50VHA3
PAC-SG59SG-E - Air outlet guide PUHZ-RP60-250V/YHA2/3, 2 sets required for sizes 100-250

System Control Units PAC-SE55RA-E - Remote on/off adaptor


PAC-SF40RM-E - Run/fault indication
PAC-YT32PTA-E - Program timer
PAC-SE41TS-E - Remote sensor
PAC-SF80MA - A/M-NET adaptor
PAC-YT51CRA - Simplified remote controller
PAR-21MAA - Wired controller
PAC-SK81SI-E - Sub interface board

Pipe Kits MSDD-50SR-E - Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140
MSDD-50WR-E - Multi distribution pipe twin units - 50:50 - sizes 200/250
MSDT-111R-E - Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250
MSDF-1111R-E - Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250
Accessories / Optional Extras

Power Supply Terminal Kits PAC-SH52HR-E - Power supply terminal kit for PLA-RP when using PUHZ-RP200/250YHA2
PAC-SG96HR-E - Power supply terminal kit for PKA-RP / PCA-RP / PSA-RP when using PUHZ-RP200/250YHA2
PAC-SG97HR-E - Power supply terminal kit for PEAD-RP / PCA-RP-HA when using PUHZ-RP200/250YHA2

Page 116
City Multi
Energy Efficient VRF Systems
The City Multi range
Solutions for more demanding applications

Efficient &
The City Multi range is Mitsubishi Electric’s answer to large scale
VRF (Variable Refrigerant Flow) applications. The efficiency of City Multi
is second to none and offers a substantial increase in energy efficiency, with
corresponding EER/COP ratings.
The City Multi Y Series range offers a simple and flexible solution where there is a demand for
a changeover capability between heating and cooling, helping to ensure a constant, comfortable
indoor climate.

Mitsubishi Electric also has the ability to provide simultaneous heating and cooling through its R2 and WR2
systems. The difference here being that this is achieved through only two pipes rather than the
conventional three. By using Mitsubishi Electric’s 2-pipe heat recovery technology, substantial savings
can again be made on annual running costs. With a wide range of 76 indoor units, up to 50
(depending on the capacity available) can be connected to a YHM outdoor unit.

Broadening the range of potential City Multi applications is Mitsubishi Electric’s 3rd generation water
cooled R410A WR2 system. This system not only produces heat recovery from the refrigerant circuit
but also via its water circuit, offering double heat recovery potential.

Sophisticated technology, combined with a high level of control and energy efficiency:
City Multi is perfectly positioned to meet the demands of today’s market.

Page 118
flexible
The Strength of City Multi
The R410A YHM-A series offers some of the highest EER/COP
ratings in the market.
The Basics
What is VRF?
VRF stands for Variable Refrigerant Flow. A VRF air conditioning system modulates the flow of
refrigerant depending upon the capacity requirements of the building. A VRF system comprises of a
condensing unit sited externally and a series of multiple indoor units to provide cooling and/or
heating to the occupied space.

Our answer to VRF


Mitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available
using R410A refrigerant with zero ODP (Ozone Depletion Potential). The range has been specifically
designed for today's building requirements and addresses key market issues such as energy efficiency,
adaptability and reliability. Mitsubishi Electric manufactures the only 2-pipe heat recovery
simultaneous heating and cooling system in the world and equally unique, a water-cooled version.
With user friendly control systems utilising Internet technology and integrated cooling
and ventilation indoor units, City Multi is the benchmark and market leader in VRF technology.

What is inverter driven technology?


Mitsubishi Electric spends more than 5% of its turnover on research and development, with our
engineers always looking at ways in which we can improve and lead in air conditioning efficiency.
The use of inverter technology in our City Multi systems is paramount in this process, working by
varying the compressor speed to match the cooling or heating load, thereby consuming only the
power necessary to match the exact requirement of the room. When City Multi is operating at
partial load, the energy efficiency of the system is significantly higher than at full load. In a typical
application partial load conditions prevail for more than 90% of operation time. A fixed speed system
can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system

What is a Heat Pump system?


Mitsubishi Electric’s City Multi Y Series, is a heat pump system, which provides either heating or
cooling to a building at any given time.

What is a Heat Recovery system?


Mitsubishi Electric’s City Multi R2 and WR2 series’ have the ability to provide heating and cooling at
the same time in areas connected to the same outdoor unit.

Page 120
Why R410A? Why Heat Recovery?
R410A is a more efficient refrigerant as it has a higher specific Flexibility and efficiency are key factors when selecting a heat
heat capacity when compared to R407c or R22. This higher recovery system. For example, while a heat pump system is
energy carrying capacity allows for smaller pipe sizes, longer pipe adequate for a large open plan office, businesses that have a
runs and reduces the volume of refrigerant within a system. more partitioned structure to an office will require the need
to simultaneously heat or cool different sections of the office
This is a major factor when complying with EN378, a according to each users individual preferences.
European standard concerning safety and environmental
requirements in the design, manufacture, installation, The efficiency of this type of system comes from the ability to
operation, maintenance and disposal of refrigerating systems. use the by-products of cooling and heating to transfer energy
where it is required, thus acting as a balanced heat exchanger
achieving up to 20% cost savings over a conventional heat
pump system.

The number of connection sites needed for a R2 / WR2


system are also significantly lower than those needed for a
three pipe version. This helps to reduce installation costs,
further increasing the savings associated with City Multi.

Comparison
example of piping
connection sites

= 2 sites = 3 sites

How does the R2 / WR2 Heat Recovery System operate


on 2 Pipe’s?
The secret of City Multi heat
recovery systems lies in the

BC Controller
The BC Controller houses a liquid/gas separator, allowing the
outdoor unit to deliver a mixture (2 phase) of hot gas for heating
and liquid for cooling, all through the same pipe. Three pipe systems
allocate a pipe to each of these phases. When this mixture arrives
at the BC Controller, it is separated and the correct phase delivered
to each indoor unit depending on the individual requirement of
either heating or cooling.

Page 121
The technology to make
City Multi the natural choice
Energy efficiency has always been the driver for City Multi technological
development. Technology that always delivers the quality and reliability needed
for commercial air conditioning environments. Mitsubishi Electric spend more
than 5% of their turnover on research and development, with our engineers always
looking at ways in which we can improve and lead in air conditioning efficiency.

City Multi R410A YHM-A technology


Using the ver y latest in IPM (Intelligent Power Module) technology, precise control of
energy input is achieved allowing City Multi to fur ther improve COPs for R410A systems.
IPM uses 1Hz steps of capacity control, matching building requirements through more accurate
control of the occupied space with reduced power input.

As in previous versions, IPM technology operates extremely effectively under part load conditions
(50-80% of operating capacity), a condition that most systems will be in for their normal working life.
Therefore the consideration of efficiency at part load is accounted for as well as when at peak load
conditions, offering high system efficiency all year round.

Stable and smooth operation - 100% inverter control


All City Multi compressors are inverter-driven - Capable of precisely matching a
building's cooling and heating demands.
The outdoor unit combinations comprise of one module for 8-18hp systems (for R2 up to
16hp), two modules for 20-36hp systems (for R2, 18-32hp) and three modules for 38-50hp
systems (Y series only). Each module carries one inverter compressor making simple and highly
reliable control possible. Not only does it allow low starting currents, the inverter driven
compressor also provides precise indoor comfort and adapts to the air conditioning load,
achieving smooth transition across the range of compressor frequencies.

Y Series 8-18hp / R2 8-16hp Y Series 20-36hp / R2 18-32hp Y Series 38-50hp

Page 122
Heat Interchange Circuit The difference between
YHM-A and previous
To further enhance the class leading efficiency of City Multi, the unique Heat
Interchange Circuit provides extra sub cooling. This system allows optimum Mitsubishi Electric models
refrigerant distribution to multiple indoor units, by allowing more effective
use of refrigerant flowing through the electronic expansion valves. Technology is key when increased
efficiency is demanded. The City Multi
Because of the added efficiency, volumes of refrigerant in systems are YHM-A range is designed to deliver this.
continuing to reduce.
A highly efficient R410A scroll compressor
design results in less friction losses at the motor.
A simplified refrigerant circuit (low pressure loss)
including new accumulator design also adds a
few more points to the efficiency scale.

Enhancements to the heat interchange circuit,


inverter driven fan motor and heat exchanger
CITY MULTI NORMAL design, again add vital increases to overall system
REFRIGERANT REFRIGERANT
CIRCUIT CIRCUIT efficiency and COPs.

Total Energy
Conser vation
The importance of COP Total Energy Conservation
COP stands for “Co-efficient of Performance”. It is a measure of the Comparison of COP (energy efficiency)
useful energy a system can deliver compared to the energy that of an 8hp YHM-A system.
it consumes. It is calculated by dividing the energy output by
the energy input of a system. The higher the figure then the more
efficient the system is deemed to be, with commensurate reduced
running costs.

For Heat Pumps to be included on the Energy Technology Product List


under the Enhanced Capital Allowance scheme, they must achieve a
heating COP of 3.4 and a cooling EER (energy efficiency ratio) of 3.0.
Therefore every input of 1kW of energy must deliver an output
of 3.4kW for heating and 3.0kW for cooling, achieving an energy
label of B.

Page 123
Ground Source
Heat Pumps
A very efficient source of energy for water source heat pump systems is the Earth
itself. Ground source heat pumps use the Earth's natural solar collection and heat
storage capabilities as an infinite heat source/heat sink.
At between 1.7m and 3m below the ground, the temperature changes from 17ºC in the summer to 10ºC in the winter.
Deeper down however, the temperature of the ground is a constant 10ºC all year round. It is these relatively constant,
dependable temperatures that can be harnessed using ground source heat pumps.

The constant ground temperatures allow the heat pump to operate at optimum efficiency in both heating and cooling,
as the high summer or low winter temperatures do not influence performance. Heat is extracted or
rejected into the ground using water which is pumped through a network of plastic pipes.

There are two standard ground source methods available,


Open Loop and Closed Loop (Bore Hole or Slinky):
I Open Loop - Large bodies of water can be utilised as a stable source of water at a
relatively constant temperature. This can be either surface water or ground water.
Surface water would include lakes, reservoirs, rivers and the sea.
I Closed Loop Slinky - A trench is dug to a depth of between 1.7 to 3m and plastic
spiral pipe is laid into the bottom. The pipe is covered with sand to provide good ground
to pipe contact and then the trench is backfilled with the excavated soil.
I Closed Loop Bore Hole - A series of holes are drilled down into the ground at a depth
of 50 to 130m, depending on geothermal conditions. Two water pipes connected via a 'u bend'
are fed directly into these holes and then surrounded by a conductive grout.

Example of a Closed Loop


Bore Hole Application:

Indoor units provide heating or cooling

Ground Source Heat Pump installed inside


the building, typically 1 per floor

Flow and return water loop supplies


water to and from the units

Bore Hole absorbs or rejects heat from the ground

Page 124
Highly eff icient &
extremely flexible
New Acoustic Kits for PUHY
and PURY Series units
A range of Acoustic Kits designed for noise reduction.
An industry first, the kits offer a 6dBA noise level
reduction from standard.
For supply and / or installation please contact
Ambient Acoustics on 01934 712802

Page 125
Features and
High off coil / High sensible cooling
Poor design or application of air conditioning systems can sometimes lead to cold draughts and
uneven room temperatures. Low off coil temperatures cause dehumidifying of the air which can
create dry eyes and sore throats.

Mitsubishi Electric now provides a High Sensible Cooling Function specifically designed to deal with
this. By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard
operation is achievable, the result being greater comfort for occupants. These high SHF’s are available
throughout the range of indoor units, allowing optimum selection of units tailored to more specific
design criteria.

Reduced noise levels


New fan design
City Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achieving
substantially lower noise levels over multiple designs. Continuing the development in the areas of blade
shape and weight, Mitsubishi Electric have managed to achieve even higher performance and lower
noise levels.

To reduce noise levels further and comply with inner city residential noise regulations, all outdoor units
include Night Set-back mode. This function works by lowering the fan speed and compressor
frequency proportionally with reduction in demand (44dBA for PUHY-P250YHM-A). The compressor
compartment is also now sealed, further reducing noise levels.

New fan design


Reduction of operation noise

New control box design


Improvement of reliability
and easy maintenance

New heat exchanger design


Improvement of COP

New inverter compressor


Improvement of COP

Page 126
Benefits

Fine Control of the Inverter Provides


Better Efficiency and Performance
Air cooled inverters use the ambient temperature to cool the inverter. For water cooled VRF (which
are installed inside the building) refrigerant cooling is used to maintain accurate control of the Inverter.

Refrigerant volume checking function


This function runs the system, measuring various temperatures and pressures throughout the
system, comparing these to the values stored in the units memory from the previous service.
If a leakage has occurred the system will indicate so, enabling customers to easily comply with
the F-Gas regulation.

Replace technology
This unique function allows the re-use of refrigerant piping, controllers, power and control
wiring for all previously installed Mitsubishi Electric R22 and R407c Heat Recovery and Cooling
only systems and partial replace of Heat Pumps (pressure regulations require one pipe from
the outdoor to the first branch to be replaced). This function offers unprecedented savings on
installation costs, disruption to business and down time, not to mention the considerable
running cost and CO2 emission savings - more than halving the running costs compared to a
10 year old unit.

Cooling operation set temperature of 14ºC


Environments such as gyms, laboratories etc often require the ability to cool lower than the standard
comfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation set
temperature of 14ºC DB is possible on the floor standing and ducted models only. The indoor
unit fan will be fixed at high speed during this operation.

Page 127
Effective use of space
The new models have a smaller foot print requirement than previous models. The width and depth
have been reduced by 7% and 13% respectively, with the height being reduced by 130mm.
(PUHY-P250YHM-A compared to previous YGM-A versions).

mm YGM-A YHM-A

8-12hp systems (Y / R2 Series) 14-18hp systems (Y Series)


1.43m2 14-16hp systems (R2 Series) Approximately 21% reduction in foot print
1.89m2 (PUHY-P250)

The unit can easily be transported, even into inaccessible buildings

The narrow space between buildings


makes it difficult to use a crane

The downsized outdoor unit can be transported through an 800mm wide lift door

8-12hp outdoor units Example of lift

Weight reduction
Weight has been reduced
by approximately 33kg 33kg
(PUHY-P250YHM-A
compared to previous
YGM-A versions).

YGM-A YHM-A

Page 128
Blue Fin treatment
The anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban
environments where the traffic pollutions can damage the aluminium fins reducing
the capacity and life expectancy of the unit.

All City Multi R410A outdoor units


have been treated with Blue Fin

R410A pipe sizing


As R410A has a higher specific heat capacity
than R22, the pipework is smaller. This means
the pipe itself is cheaper, easier to install and
less riser space is required within the building.
10hp model

Constant & comfortable


indoor climates
Heating operation range - Water temperature
Air cooled units operation range -
At low ambient temperatures the guaranteed operating WR2 / WY Water cooled units
range in heating is minus 20ºC
Operating range in cooling is from an outdoor
temperature of -5ºC.

Outdoor Temperature (ºC) Water Temperature (ºC)

Page 129
City Multi exceeds
current demands
for Efficiency
The need for energy efficiency is paramount and is determined by legislation and regulation.
Businesses saw their energy bills rise by up to 15% with the introduction of the Climate Change
Levy in April 2001. A year later, the newly revised Par t L (Par t J in Scotland) of the building
regulations placed new standards on design of buildings and plant deployed for heating, cooling and
ventilating. A revised version to conform with the Energy Performance of Buildings Directive was also
introduced in 2006; all geared to reducing energy consumption and therefore CO2 emissions.

To encourage efficient use of energy, the UK Government introduced the Enhanced Capital
Allowance Scheme (ECA). Qualifying products on the Energy Technology Product List include heat
pumps for space heating. The City Multi range has been designed to ensure businesses qualify for
ECA and benefit from the utmost efficiency, both financially and environmentally.

Mitsubishi Electric has produced a series of comprehensive CPD approved guides.


These include:
I The Energy Performance of Buildings Directive (EPBD)
I Mixed Mode Cooling Systems
I Building Energy Management Systems (BEMS)
I Water Cooled VRF Systems
I The European F-Gas Regulation
I The New Part L of the Building Regulations 2006
I The New 10% Renewable Energy Target
I Heat Pump Boilers
I Part F of the Building Regulations
I The Code for Sustainable Homes
I Building Energy Ratings
I Renewable Energy Sources
I Maintenance, Replacement and the WEEE Directive
I Combined Heat and Power
I Carbon Reduction in the Built Environment
I The Application of Heat Pump Boilers
I The Enhanced Capital Allowance Scheme (2008)

Page 130
Enhanced Capital
Allowance Scheme (ECA)
The key features of the scheme:
I Under the scheme, all businesses liable for UK corporation tax, are able to claim an enhanced capital allowance on any
qualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector)

I Businesses can offset the full cost of specific technologies (such as City Multi) against taxable profits
of the period of the investment

I In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the Energy Technology
Criteria List. City Multi fully meets this criteria in its drive for energy efficiency

I Only investment in new and unused plant and machinery qualify

For further information go to www.eca.gov.uk and click on


Mitsubishi Electric Air Conditioning under the heat pump category.

Page 131
A wide choice of models
The new YHM-A air sourced outdoor models are modular in design and as such differing
combinations of them can be connected together to create the required outdoor unit size needed
for a particular application.
Both the Y Series and R2 ranges come in standard (-P) and high COP (-EP) versions. In addition, the standard versions
allow for space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.

The model line up


Size 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250

Series Model Name 8hp 10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp

Y PUHY-P YHM-A I I I I I I I I I I I I I I I I I I I I I
PUHY-EP YHM-A I I I I I I I I I I I I I
R2 PURY-P YHM-A I I I I I I I I I I I
PURY-EP YHM-A I I I I I I I

Y Series Heat Pump - Standard Version


Y Series (10-12hp) PUHY-P YHM-A Y Series (14 - 18hp) PUHY-P YHM-A Y Series (20 - 26hp) PUHY-P YSHM-A

10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp


PUHY-P250YHM-A PUHY-P300YHM-A PUHY-P350YHM-A PUHY-P400YHM-A PUHY-P450YHM-A PUHY-P500YSHM-A PUHY-P550YSHM-A PUHY-P600YSHM-A PUHY-P650YSHM-A

Y Series (28-36hp) PUHY-P YSHM-A Y Series (38 - 40hp) PUHY-P YSHM-A Y Series (42hp) PUHY-P YSHM-A

28hp 30hp 32hp 38hp 40hp 42hp


PUHY-P700YSHM-A PUHY-P750YSHM-A PUHY-P800YSHM-A PUHY-P950YSHM-A PUHY-P1000YSHM-A PUHY-P1050YSHM-A

34hp 36hp
PUHY-P850YSHM-A PUHY-P900YSHM-A
Y Series (44-50hp) PUHY-P YSHM-A

44hp 46hp 48hp 50hp


PUHY-P1100YSHM-A PUHY-P1150YSHM-A PUHY-P1200YSHM-A PUHY-P1250YSHM-A

Page 132
Y Series Heat Pump - High COP Version
Y Series - High COP (8 - 12hp) PUHY-EP YHM-A Y Series - High COP (16 - 20hp) PUHY-EP YSHM-A Y Series - High COP (22 - 26hp) PUHY-EP YSHM-A

8hp 12hp 16hp 18hp 20hp 22hp 24hp 26hp


PUHY-EP200YHM-A PUHY-EP300YHM-A PUHY-EP400YSHM-A PUHY-EP450YSHM-A PUHY-EP500YSHM-A PUHY-EP550YSHM-A PUHY-EP600YSHM-A PUHY-EP650YSHM-A

Y Series - High COP (28 - 30hp) PUHY-EP YSHM-A Y Series - High COP (32 - 34hp) PUHY-EP YSHM-A Y Series - High COP (36hp) PUHY-EP YSHM-A

28hp 30hp 32hp 34hp 36hp


PUHY-EP700YSHM-A PUHY-EP750YSHM-A PUHY-EP800YSHM-A PUHY-EP850YSHM-A PUHY-EP900YSHM-A

R2 Series Heat Recovery - Standard Version


R2 Series (10 - 12hp) PURY-P YHM-A R2 Series (14 - 16hp) PURY-P YHM-A R2 Series (18 - 24hp) PURY-P YSHM-A

10hp 12hp 14hp 16hp 20hp 22hp 24hp


PURY-P250YHM-A PURY-P300YHM-A PURY-P350YHM-A PURY-P400YHM-A PURY-P500YSHM-A PURY-P550YSHM-A PURY-P600YSHM-A

R2 Series (26 - 28hp) PURY-P YSHM-A R2 Series (30 - 32hp) PURY-P YSHM-A

26hp 28hp 30hp 32hp


PURY-P650YSHM-A PURY-P700YSHM-A PURY-P750YSHM-A PURY-P800YSHM-A

R2 Series Heat Recovery - High COP Version


R2 Series - High COP (8 -12hp) PURY-EP YHM-A R2 Series - High COP (16 - 18hp) PURY-EP YSHM-A R2 Series - High COP (20 - 22hp) PURY-EP YSHM-A

8hp 12hp 16hp 18hp 20hp 22hp


PURY-EP200YHM-A PURY-EP300YHM-A PURY-EP400YSHM-A PURY-EP450YSHM-A PURY-EP500YSHM-A PURY-EP550YSHM-A

R2 Series - High COP (24hp) PURY-EP YSHM-A

24hp
PURY-EP600YSHM-A

Page 133
City Multi Product Range Overview
Outdoor Units
14kW Cooling Capacity
Y Series (4/5/6hp) WY / WR2 WY / WR2

PUMY-P100-140V/YHMA PQ(H/R)Y-P200/250YGM-A PQ(H/R)Y-P400/500YSGM-A

Indoor Units
15 20 25 32 40
Model / Size
(1.7kW) (2.2kW) (2.8kW) (3.6kW) (4.5kW)

PLFY-P-VBM-E

PLFY-P-VCM-E

PLFY-P-VLMD-E

PMFY-P-VBM-E

PEFY-P-VMS1-E

PEFY-P-VMM-E

PEFY-P-VMH-E

PCFY-P-VGM-E

PKFY-P-VBM/VGM/VFM-E

PFFY-P-VLRM-E

PFFY-P-VLRMM-E

PFFY-P-VLEM-E

PFFY-P-VKM-E

GUF-RD3

PQFY-P

Page 134
140kW Cooling Capacity
Y / R2 Series Standard Y / R2 Series High COP Y / R2 Series Standard Y / R2 Series High COP

PUH/RY-P250/300YHM-A PUH/RY-EP200YHM-A PUH/RY-P350-450YHM-A*1 PUH/RY-EP300YHM-A

50 63 80 100 125 140 250


(5.6kW) (7.1kW) (9.0kW) (11.2kW) (14.0kW) (16.0kW) (28.0kW)

*1 Size 450 only available for Y Series

Page 135
The energy efficient
City Multi VRF range
Unique 2-pipe technology provides

simultaneous heating and cooling, alongside excellent energy

efficiency and corresponding EER/COP

ratings. Up to 50 indoor units can be connected to a single

outdoor unit, offering the sophistication,

control and energy efficiency

demanded today.

Simple technology
at its best
Systems marked with the ECA logo are registered on the Energy Technology List and
hence qualify for 100% first year enhanced capital allowances (whole system cost and
‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 136
Contents
138 Y Series (4-6hp) Heat Pump, Outdoor Unit
140 Y Series Standard (10-18hp) Heat Pump, Outdoor Unit
142 Y Series Standard (20-36hp) Heat Pump, Outdoor Unit
144 Y Series Standard (38-50hp) Heat Pump, Outdoor Unit
146 Y Series High COP (8-26hp) Heat Pump, Outdoor Unit
148 Y Series High COP (28-36hp) Heat Pump, Outdoor Unit
150 WY Series (8-20hp) Water Cooled Heat Pump, Outdoor Unit
152 R2 Series Standard (10-16hp) Heat Recovery, Outdoor Unit
154 R2 Series Standard (20-32hp) Heat Recovery, Outdoor Unit
156 R2 Series High COP (8-24hp) Heat Recovery, Outdoor Unit
158 R2 Series Piping Restrictions
160 WR2 Series (8-20hp) Water Cooled Heat Recovery, Outdoor Unit
162 PFD-P-VM-E Heat Pump, Close Control System
164 PLFY-P-VBM-E 2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
166 PLFY-P-VCM-E 600x600 4-Way Blow Ceiling Cassette Indoor Unit
168 PLFY-P-VLMD-E 2-Way Blow Ceiling Cassette Indoor Unit
170 PMFY-P-VBM-E 1-Way Blow Ceiling Cassette Indoor Unit
172 PEFY-P-VMS1-E Ultra Thin Ceiling Concealed Ducted Indoor Unit
174 PEFY-P-VMM-E Ceiling Concealed Ducted Indoor Unit
176 PEFY-P-VMH-E High Static Pressure Ceiling Concealed Ducted Indoor Unit
178 PCFY-P-VGM-E Ceiling Suspended Indoor Unit
180 PKFY-P-VBM/VGM/VFM-E Wall Mounted Indoor Unit
182 PFFY-P-VLRM-E Floor Standing Concealed Indoor Unit
184 PFFY-P-VLRMM-E Floor Standing Concealed Indoor Unit
186 PFFY-P-VLEM-E Floor Standing Exposed Indoor Unit
188 PFFY-P-VKM-E Floor Standing Exposed Indoor Unit
190 GUF-RD3 Lossnay Outdoor Air Processing Unit
192 PQFY-P VRF Heat Pump Boiler
194 BC Controllers
196 Air Handling Unit Controllers
197 Accessories / Optional Extras

Page 137
Y Series (4-6hp)
Heat Pump Outdoor Unit
The latest in Mitsubishi Electric R410A Y Series technology. The new City Multi models allow up to
8 indoor units to be connected to a single outdoor unit, using the standard branch/header pipework system
proven in the larger models. Utilising the latest Mitsubishi Electric inver ter technology,
the system is fully controllable with all City Multi controllers or linked to third party BEMS.

I A two core non-polar transmission line allows for simple


installation of up to eight indoor units
I Latest in inverter technology including a highly efficient
DC Scroll Compressor, DC fan motor and Demand Control
I The condensing unit is extremely slimline which allows easy location
and application of the system
I Single or three phase power supply
I Anti-Corrosion blue and flat fin technology
I Size 15 PEFY-P-VMS1-E now able to connect to PUMY

Technical Information
Y SERIES OUTDOOR UNIT - 4-6hp
MODEL REFERENCE PUMY-P100VHMA PUMY-P100YHMA PUMY-P125VHMA PUMY-P125YHMA PUMY-P140VHMA PUMY-P140YHMA
CAPACITY (kW) Heating (nominal) 12.5 12.5 16.0 16.0 18.0 18.0
Cooling (nominal) 11.2 11.2 14.0 14.0 15.5 15.5
Heating (UK) 10.4 10.4 13.3 13.3 14.9 14.9
Cooling (UK) 10.3 10.3 12.9 12.9 14.3 14.3
POWER INPUT (kW) Heating (nominal) 3.66 3.63 4.33 4.29 5.58 5.32
Cooling (nominal) 3.34 3.3 4.32 4.27 5.35 5.32
Heating (UK) 3.27 3.23 3.85 3.82 4.99 4.73
Cooling (UK) 2.84 2.81 3.66 3.63 4.53 4.52
COP / EER (nominal) 3.42 / 3.35 3.44 / 3.39 3.69 / 3.24 3.73 / 3.28 3.23 / 2.90 3.38 / 2.91
Max no. OF CONNECTABLE INDOOR UNITS 6 6 8 8 8 8
Max CONNECTABLE CAPACITY 14.5 (130%) 14.5 (130%) 18.2 (130%) 18.2 (130%) 20.2 (130%) 20.2 (130%)
AIRFLOW (m3/min) 100 100 100 100 100 100
PIPE SIZE mm(in) Gas 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
NOISE (dBA) Heating/Cooling 51 / 49 51 / 49 52 / 50 52 / 50 53 / 51 53 / 51
WEIGHT (kg) 127 140 127 140 127 140
DIMENSIONS (mm) Width 950 950 950 950 950 950
Depth 330+30 330+30 330+30 330+30 330+30 330+30
Height 1350 1350 1350 1350 1350 1350
ELECTRICAL SUPPLY 220-240v, 50Hz 380-415v, 50Hz 220-240v, 50Hz 380-415v, 50Hz 220-240v, 50Hz 380-415v, 50Hz
PHASE Single 3 Single 3 Single 3
STARTING CURRENT (A) 5 5 5 5 5 5
RUNNING CURRENT (A) Heating 15.5 5.32 18.3 6.29 23.6 7.8
Cooling 14.1 4.84 18.3 6.26 22.7 7.8
GUARANTEED OPERATING RANGE Cooling -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC
Heating -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC
FUSE RATING (BS88) - HRC (A) 40 16 40 16 50 16
MAINS CABLE No. Cores 3 4 + earth 3 4 + earth 3 4 + earth

Optional Parts
PUMY-P100-140VHMA/YHMA Piping Restrictions Model Name Description
TOTAL PIPING LENGTH 120m max CMY-Y62-G-E Branch Pipe (2 Branch)
FURTHEST PIPING LENGTH 80m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH 30m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 30m max (20m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 12m max

Page 138
City Multi Range 2008
Dimensions

PUMY-P100-140VHMA/YHMA

Upper View >

Side View > Front View >

Y Series (4-6hp)

Page 139
Y Series Standard (10-18hp)
Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with
the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual
changeover from cooling to heating to ensure that a constant indoor climate is maintained.

I New wrap around coil for improved energy efficiency


I Choice of Branch Pipe or Header Pipe feeds to indoor units
I Energy-saving inverter driven outdoor compressor units with very
low start currents
I No requirement for plant rooms or bulky service shafts
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m, with a total system pipe length of 1000m
I 100% inverter control
I High Sensible Cooling Function - By raising the off coil temperature, a 10%
increase in sensible cooling capacity over standard operation is achievable,
the result being greater comfort for occupants

Technical Information
Y SERIES STANDARD OUTDOOR UNITS 10-18hp
MODEL REFERENCE PUHY-P250YHM-A PUHY-P300YHM-A PUHY-P350YHM-A PUHY-P400YHM-A PUHY-P450YHM-A
CAPACITY (kW) Heating (nominal) 31.5 37.5 45.0 50.0 56.0
Cooling (nominal) 28.0 33.5 40.0 45.0 50.0
Heating (UK) 28.7 33.0 39.6 44.0 48.7
Cooling (UK) 26.6 31.5 37.6 42.3 46.0
POWER INPUT (kW) Heating (nominal) 7.83 9.39 12.09 13.47 15.38
Cooling (nominal) 7.73 9.07 11.20 13.23 16.28
Heating (UK) 7.75 9.11 11.73 13.07 14.00
Cooling (UK) 4.79 6.71 8.29 9.79 11.40
COP/EER (nominal) 4.02 / 3.62 3.99 / 3.69 3.72 / 3.57 3.71 / 3.40 3.64 / 3.07
MAX No. OF CONNECTABLE INDOOR UNITS 21 26 30 34 39
AIRFLOW (m3/min) High 185 185 225 225 225
NOISE (dBA) 57 59 60 61 62
WEIGHT (kg) 200 215 245 245 245
DIMENSIONS (mm) Width 920 920 1220 1220 1220
Depth 760 760 760 760 760
(1650mm without legs) Height 1710 1710 1710 1710 1710
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3 3
STARTING CURRENT (A) 8 8 8 8 8
RUNNING CURRENT (A) Heating 12.1 14.5 18.6 20.8 23.7
Cooling 11.9 14.0 17.3 20.4 25.1
FUSE RATING (MCB sizes BS EN 60947-2) - (A) 32 32 32 40 50
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

PUHY-P250-450YHM-A Piping Restrictions


TOTAL PIPING LENGTH 1000m max
FURTHEST PIPING LENGTH 165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 15m max

Page 140
City Multi Range 2008
Dimensions

PUHY-P250, 300YHM-A Upper View >

Side View >


Front View >

PUHY-P350, 400, 450YHM-A Upper View >

Side View >


Front View >
Y Series Standard (10-18hp)

Page 141
Y Series Standard (20-36hp)
Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout,
with the choice of either Branch Pipe or Header Pipe feeds to indoor units,
with manual changeover from cooling to heating to ensure that a constant
indoor climate is maintained.

I New wrap around coil for improved energy efficiency


I Choice of Branch Pipe or Header Pipe feeds to indoor units
I Energy-saving inverter driven outdoor compressor units with
very low start currents
I No requirement for plant rooms or bulky service shafts
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m, with a total system pipe length of 1000m
I 100% inverter control
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation
is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES STANDARD OUTDOOR UNITS 20-36hp
MODEL REFERENCE PUHY-P500YSHM-A PUHY-P550YSHM-A PUHY-P600YSHM-A PUHY-P650YSHM-A PUHY-P700YSHM-A PUHY-P750YSHM-A PUHY-P800YSHM-A PUHY-P850YSHM-A PUHY-P900YSHM-A

CAPACITY (kW) Heating (nominal) 63.0 69.0 76.5 81.5 88.0 95.0 100.0 108.0 113.0

Cooling (nominal) 56.0 63.0 69.0 73.0 80.0 85.0 90.0 96.0 101.0

Heating (UK) 54.8 60.0 66.6 70.9 75.7 81.7 86.0 95.0 99.4

Cooling (UK) 51.5 58.0 63.5 67.2 73.6 78.2 82.8 88.3 92.9

POWER INPUT (kW) Heating (nominal) 16.40 18.06 19.92 21.90 23.71 25.46 25.70 28.42 30.29

Cooling (nominal) 16.47 18.36 18.75 20.79 22.47 25.07 27.69 30.18 33.33

Heating (UK) 14.92 16.43 18.13 19.93 22.05 23.68 23.90 26.15 27.87

Cooling (UK) 11.53 12.85 13.13 14.55 16.18 18.05 19.94 19.92 22.00

COP/EER (nominal) 3.84 / 3.40 3.82 / 3.43 3.84 / 3.68 3.72 / 3.51 3.71 / 3.56 3.73 / 3.39 3.89 / 3.25 3.80 / 3.18 3.73 / 3.03

MAX No. OF CONNECTABLE INDOOR UNITS 43 47 50 50 50 50 50 50 50

AIRFLOW (m3/min) High 185 / 185 185 / 185 225 / 185 225 / 185 225 / 225 225 / 225 225 / 225 225 / 225 225 / 225

NOISE (dBA) 60 60.5 60.5 61 61 63 64 64.5 64.5

WEIGHT (kg) 200 + 200 215 + 200 245 + 200 245 + 215 245 + 245 245 + 245 245 + 245 245 + 245 245 + 245

DIMENSIONS (mm) Width 920 + 920 920 + 920 1220 + 920 1220 + 920 1220 + 1220 1220 + 1220 1220 + 1220 1220 + 1220 1220 + 1220

Depth 760 760 760 760 760 760 760 760 760

(1650mm without legs) Height 1710 1710 1710 1710 1710 1710 1710 1710 1710

ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz

PHASE 3 3 3 3 3 3 3 3 3

STARTING CURRENT (A) 8/8 8/8 8/8 8/8 8/8 8/8 8/8 8/8 8/8

RUNNING CURRENT (A) Heating 25.3 27.9 30.7 33.8 36.6 39.3 39.7 43.9 46.8

Cooling 25.4 28.3 28.9 32.1 34.7 38.7 42.8 46.6 51.5

FUSE RATING (MCB sizes BS EN 60947-2) - (A) 32 / 32 32 / 32 32 / 32 32 / 32 32 / 32 40 / 32 50 / 32 50 / 40 50 / 50

MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

PUHY-P500-900YSHM-A Piping Restrictions


TOTAL PIPING LENGTH 1000m max
FURTHEST PIPING LENGTH 165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 15m max

Page 142
City Multi Range 2008
Dimensions

PUHY-P500, 550YSHM-A

Side View > Front View >

PUHY-P600, 650YSHM-A
Side View > Front View >

PUHY-P700, 750, 800, 850, 900YSHM-A


Side View > Front View >
Y Series Standard (20-36hp)

Page 143
Y Series Standard (38-50hp)
Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout,
with the choice of either Branch Pipe or Header Pipe feeds to indoor units,
with manual changeover from cooling to heating to ensure that a constant
indoor climate is maintained.

I New wrap around coil for improved energy efficiency


I Choice of Branch Pipe or Header Pipe feeds to indoor units
I Energy-saving inverter driven outdoor compressor units with
very low start currents
I No requirement for plant rooms or bulky service shafts
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m, with a total system pipe length of 1000m
I 100% inverter control
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation
is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES STANDARD OUTDOOR UNITS 38-50hp
MODEL REFERENCE PUHY-P950YSHM-A PUHY-P1000YSHM-A PUHY-P1050YSHM-A PUHY-P1100YSHM-A PUHY-P1150YSHM-A PUHY-P1200YSHM-A PUHY-P1250YSHM-A
CAPACITY (kW) Heating (nominal) 119.5 127.0 132.0 140.0 145.0 150.0 156.5
Cooling (nominal) 108.0 113.0 118.0 124.0 130.0 136.0 140.0
Heating (UK) 105.2 111.8 116.2 123.2 127.6 132.0 137.7
Cooling (UK) 99.4 104.0 108.6 114.1 119.6 125.1 128.8
POWER INPUT (kW) Heating (nominal) 30.02 33.15 35.01 36.93 39.08 40.10 42.06
Cooling (nominal) 30.68 32.47 33.90 35.83 39.39 41.71 45.01
Heating (UK) 27.62 30.50 32.21 33.98 35.95 36.89 38.70
Cooling (UK) 20.25 21.43 22.37 23.65 26.00 27.53 29.71
COP/EER (nominal) 3.98 / 3.52 3.83 / 3.48 3.77 / 3.48 3.79 / 3.46 3.71 / 3.30 3.74 / 3.26 3.72 / 3.11
MAX No. OF CONNECTABLE INDOOR UNITS 50 50 50 50 50 50 50
AIRFLOW (m3/min) High 185 / 185 / 185 225 / 185 / 185 225 / 225 / 185 225 / 225 / 225 225 / 225 / 225 225 / 225 / 225 225 / 225 / 225
NOISE (dBA) 64 64 64 64 64.5 65 65.5
WEIGHT (kg) 245 + 215 + 200 245 + 215 + 215 245 + 245 + 200 245 + 245 + 245 245 + 245 + 245 245 + 245 + 245 245 + 245 + 245
DIMENSIONS (mm) Width 1220 + 920 + 920 1220 + 920 + 920 1220 + 1220 + 920 1220 + 1220 + 1220 1220 + 1220 + 1220 1220 + 1220 + 1220 1220 + 1220 + 1220
Depth 760 760 760 760 760 760 760
(1650mm without legs) Height 1710 1710 1710 1710 1710 1710 1710
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3 3 3 3
STARTING CURRENT (A) 8/8/8 8/8/8 8/8/8 8/8/8 8/8/8 8/8/8 8/8/8
RUNNING CURRENT (A) Heating 46.4 51.2 54.1 57.0 60.4 61.9 65.0
Cooling 47.4 50.1 52.4 55.3 60.8 64.4 69.5
FUSE RATING (MCB sizes BS EN 60947-2) - (A) 40 / 32 / 32 40 / 32 / 32 40 / 32 / 32 40 / 32 / 32 50 / 32 / 32 50 / 40 / 32 50 / 50 / 32
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

PUHY-P950-1250YSHM-A Piping Restrictions


TOTAL PIPING LENGTH 1000m max
FURTHEST PIPING LENGTH 165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 15m max

Page 144
City Multi Range 2008
Dimensions

PUHY-P950, 1000YSHM-A
Side View > Front View >

PUHY-P1050YSHM-A
Side View > Front View >

PUHY-P1100, 1150, 1200, 1250YSHM-A


Side View > Front View >
Y Series Standard (38-50hp)

Page 145
Y Series High COP (8-26hp)
Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout,
with the choice of either Branch Pipe or Header Pipe feeds to indoor units,
with manual changeover from cooling to heating to ensure that a constant
indoor climate is maintained.

I Highest ever COP’s / EER’s due to new higher efficiency inverter


technology and wrap around coil
I Choice of Branch Pipe or Header Pipe feeds to indoor units
I Energy-saving inverter driven outdoor compressor units
with very low start currents
I No requirement for plant rooms or bulky service shafts
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m, with a total system pipe length of 1000m
I 100% inverter control
I High Sensible Cooling Function - By raising the off coil temperature, a 10% increase
in sensible cooling capacity over standard operation is achievable, the result being
greater comfort for occupants

Technical Information
Y SERIES HIGH COP OUTDOOR UNIT 8-26hp
MODEL REFERENCE PUHY-EP200YHM-A PUHY-EP300YHM-A PUHY-EP400YSHM-A PUHY-EP450YSHM-A PUHY-EP500YSHM-A PUHY-EP550YSHM-A PUHY-EP600YSHM-A PUHY-EP650YSHM-A

CAPACITY (kW) Heating (nominal) 25.0 37.5 50.0 56.0 63.0 69.0 76.5 81.5
Cooling (nominal) 22.4 33.5 45.0 50.0 56.0 63.0 69.0 73.0
Heating (UK) 23.0 33.0 44.0 48.7 54.8 60.0 66.6 70.9
Cooling (UK) 21.3 31.5 42.3 46.0 51.5 58.0 63.5 67.2
POWER INPUT (kW) Heating (nominal) 5.77 9.28 11.54 13.05 15.14 17.12 18.93 19.13
Cooling (nominal) 5.18 8.25 10.41 13.15 13.46 16.32 16.99 18.34
Heating (UK) 5.71 9.00 11.19 11.88 13.78 15.58 17.23 17.41
Cooling (UK) 3.21 6.11 7.70 9.21 9.42 11.42 11.89 12.84
COP/EER (nominal) 4.33 / 4.32 4.04 / 4.06 4.33 / 4.32 4.29 / 3.80 4.16 / 4.16 4.03 / 3.86 4.04 / 4.06 4.26 / 3.98
MAX No. OF CONNECTABLE INDOOR UNITS 17 26 34 39 43 47 50 50
AIRFLOW (m3/min) High 185 225 185 / 185 185 / 185 225 / 185 225 / 185 225 / 225 225 / 225
NOISE (dBA) 57 60 60 60 62 62 63 63
WEIGHT (kg) 200 245 200 + 200 200 + 200 245 + 200 245 + 200 245 + 245 245 + 245
DIMENSIONS (mm) Width 920 1220 920 + 920 920 + 920 1220 + 920 1220 + 920 1220 + 1220 1220 + 1220
Depth 760 760 760 760 760 760 760 760
(1650mm without legs) Height 1710 1710 1710 1710 1710 1710 1710 1710
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3 3 3 3 3
STARTING CURRENT (A) 8 8 8/8 8/8 8/8 8/8 8/8 8/8
RUNNING CURRENT (A) Heating 8.9 14.3 17.8 20.1 23.4 26.4 29.2 29.5
Cooling 8.0 12.7 16.0 20.3 20.8 25.2 26.2 28.3
FUSE RATING (MCB sizes BS EN 60947-2) - (A) 20 32 20 / 20 32 / 20 32 / 20 32 / 32 32 / 32 32 / 32
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

PUHY-EP200-650Y(S)HM-A Piping Restrictions


TOTAL PIPING LENGTH 1000m max
FURTHEST PIPING LENGTH 165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 15m max

Page 146
City Multi Range 2008
Dimensions

PUHY-EP200, 300YHM-A
PUHY-EP200YHM-A schematic is the same as PUHY-P250, 300YHM-A on page 141
PUHY-EP300YHM-A schematic is the same as PUHY-P350, 400, 450YHM-A on page 141

PUHY-EP400, 450YSHM-A
Side View > Front View >

PUHY-EP500, 550YSHM-A
Side View > Front View >

PUHY-EP600, 650YSHM-A
Y Series High COP (8-26hp)

Side View > Front View >

Page 147
Y Series High COP (28-36hp)
Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout,
with the choice of either Branch Pipe or Header Pipe feeds to indoor units,
with manual changeover from cooling to heating to ensure that a constant
indoor climate is maintained.
I Highest ever COP’s / EER’s due to new higher efficiency inverter
technology and wrap around coil
I Choice of Branch Pipe or Header Pipe feeds to indoor units
I Energy-saving inverter driven outdoor compressor units
with very low start currents
I No requirement for plant rooms or bulky service shafts
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m, with a total system pipe length of 1000m
I 100% inverter control
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation
is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES HIGH COP OUTDOOR UNIT 28-36hp
MODEL REFERENCE PUHY-EP700YSHM-A PUHY-EP750YSHM-A PUHY-EP800YSHM-A PUHY-EP850YSHM-A PUHY-EP900YSHM-A
CAPACITY (kW) Heating (nominal) 88.0 95.0 100.0 108.0 113.0
Cooling (nominal) 80.0 85.0 90.0 96.0 101.0
Heating (UK) 75.7 81.7 86.0 95.0 99.4
Cooling (UK) 73.6 78.2 82.8 88.3 92.9
POWER INPUT (kW) Heating (nominal) 20.00 22.19 23.41 25.59 27.90
Cooling (nominal) 20.99 21.79 22.00 24.67 24.87
Heating (UK) 18.60 20.64 21.77 23.54 25.67
Cooling (UK) 15.11 15.69 15.84 16.28 16.41
COP/EER (nominal) 4.40 / 3.81 4.28 / 3.90 4.27 / 4.09 4.22 / 3.89 4.05 / 4.06
MAX No. OF CONNECTABLE INDOOR UNITS 50 50 50 50 50
AIRFLOW (m3/min) High 225 / 185 / 185 225 / 185 / 185 225 / 225 / 185 225 / 225 / 185 225 / 225 / 225
NOISE (dBA) 63 63 64 64 65
WEIGHT (kg) 245 + 200 + 200 245 + 200 + 200 245 + 245 + 200 245 + 245 + 200 245 + 245 + 245
DIMENSIONS (mm) Width 1220 + 920 + 920 1220 + 920 + 920 1220 + 1220 + 920 1220 + 1220 + 920 1220 +1220 + 1220
Depth 760 760 760 760 760
(1650mm without legs) Height 1710 1710 1710 1710 1710
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3 3
STARTING CURRENT (A) 8/8/8 8/8/8 8/8/8 8/8/8 8/8/8
RUNNING CURRENT (A) Heating 30.9 34.3 36.1 39.5 43.1
Cooling 32.4 33.6 34.0 38.1 38.4
FUSE RATING (MCB sizes BS EN 60947-2) - (A) 32 / 20 / 20 32 / 32 / 20 32 / 32 / 20 32 / 32 / 32 32 / 32 / 32
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

PUHY-EP700-900YSHM-A Piping Restrictions


TOTAL PIPING LENGTH 1000m max
FURTHEST PIPING LENGTH 165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 15m max

Page 148
City Multi Range 2008
Dimensions

PUHY-EP700, 750YSHM-A
Side View > Front View >

PUHY-EP800, 850YSHM-A
Side View > Front View >

PUHY-EP900YSHM-A
Y Series High COP (28-36hp)

Side View > Front View >

Page 149
WY Series (8-20hp)
Heat Pump, Water Cooled Condensing Unit
The WY Series has all the benefits of the Y Series using water cooled condensing
units. It is also able to produce heat recovery via the water circuit between
heat source units, making for a very economical system.

I High COPs possible thanks to increased efficiency and careful control of the system,
allowing the largest operational water circuit temperature band ever
I Combining WY with waste heat energy provides unique application solutions
I Up to 24 indoor units can be connected to each condensing unit
I Condensing units can be situated indoors allowing greater design
flexibility and no limitation on building size
I Single inverter compressor up to 20hp
I Improved pipe run of 150m with a total system pipe length of up to 300m
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation
is achievable, the result being greater comfort for occupants
I Now able to operate with closed loop ground source water
temperatures, bore hole and slinky applications are now possible

Technical Information

WY SERIES HEAT SOURCE UNIT - 8-20hp


MODEL REFERENCE PQHY-P200YGM-A PQHY-P250YGM-A PQHY-P400YSGM-A PQHY-P500YSGM-A
CAPACITY (kW) Heating (nominal) 25.0 31.5 50.0 63.0
Cooling (nominal) 22.4 28.0 45.0 56.0
POWER INPUT (kW) Heating (nominal) 4.69 5.80 11.01 13.60
Cooling (nominal) 4.79 5.95 11.35 15.06
MAX No. OF CONNECTABLE INDOOR UNITS 13 16 22 24
NOISE (dBA) 46 47 50 53
WEIGHT (kg) 272 275 208 + 244 208 + 248
DIMENSIONS (mm) Width 990 990 1980 1980
Depth 550 550 550 550
Height 1800 1800 1800 1800
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3
STARTING CURRENT (A) 8 8 8 8
RUNNING CURRENT (A) Heating 7.2 8.9 17.0 21.0
Cooling 7.4 9.1 17.5 23.3
FUSE RATING (BS88) - HRC (A) 20 25 40 50
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth

PQHY-P200-500Y(S)GM-A Piping Restrictions


TOTAL PIPING LENGTH 300m max
FURTHEST PIPING LENGTH 150m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 15m max

Page 150
City Multi Range 2008
Dimensions

PQHY-P200, 250YGM-A

Upper View >

Left Side View >


Front View >

PQHY-P400, 500YSGM-A

Upper View >

Left Side View >


Front View >
WY Series (8-20hp)

Page 151
R2 Series Standard (10-16hp)
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency


Throughout the year, many buildings require cooling in some areas and heating in others -
even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by
distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed.
This efficiency can result in energy savings of up to 30% over conventional systems.

I New higher efficiency inverter technology, with low


start currents and wrap around coil for added efficiency
I Up to 40 indoor units connected to each outdoor unit
I Easy to install unique 2-pipe technology means minimal disruption,
quicker installation and less connections than a 3 pipe equivalents
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m with a total system pipe length of up to 600m
I 100% inverter control
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation
is achievable, the result being greater comfort for occupants

Technical Information

R2 SERIES STANDARD OUTDOOR UNIT 10-16hp


MODEL REFERENCE PURY-P250YHM-A PURY-P300YHM-A PURY-P350YHM-A PURY-P400YHM-A
CAPACITY (kW) Heating (nominal) 31.5 37.5 45.0 50.0
Cooling (nominal) 28.0 33.5 40.0 45.0
Heating (UK) 28.7 33.0 39.6 44.0
Cooling (UK) 26.6 31.5 37.6 42.3
POWER INPUT (kW) Heating (nominal) 7.83 9.58 12.47 13.71
Cooling (nominal) 7.73 9.25 12.47 13.74
Heating (UK) 7.75 9.29 12.10 13.30
Cooling (UK) 4.79 6.85 9.23 10.17
COP/EER (nominal) 4.02 / 3.62 3.91 / 3.62 3.60 / 3.20 3.64 / 3.27
MAX No. OF CONNECTABLE INDOOR UNITS 25 30 35 40
AIRFLOW (m3/min) High 185 185 225 225
NOISE (dBA) 57 59 60 61
WEIGHT (kg) 235 240 265 265
DIMENSIONS (mm) Width 920 920 1220 1220
Depth 760 760 760 760
(1650mm without legs) Height 1710 1710 1710 1710
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3
STARTING CURRENT (A) 8 8 8 8
RUNNING CURRENT (A) Heating 12.1 14.8 19.2 21.1
Cooling 11.9 14.2 19.2 21.2
FUSE RATING (MCB sizes BS EN 60947-2) - (A) 32 32 32 40
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth

Note: For piping restrictions for PURY-P250-400YHM-A please see page 158

Page 152
City Multi Range 2008
Dimensions

PURY-P250, 300YHM-A Upper View >

Side View >


Front View >

PURY-P350, 400YHM-A Upper View >

Side View >


Front View >
R2 Series Standard (10-16hp)

Page 153
R2 Series Standard (20-32hp)
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency


Throughout the year, many buildings require cooling in some areas and heating in others
- even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by
distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed.
This efficiency can result in energy savings of up to 30% over conventional systems.

I New higher efficiency inverter technology, with low start currents


and wrap around coil for added efficiency
I Up to 50 indoor units connected to each outdoor unit
I Easy to install unique 2-pipe technology means minimal disruption,
quicker installation and less connections than a 3 pipe equivalents
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m with a total system pipe length of up to 950m
I 100% inverter control
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation
is achievable, the result being greater comfort for occupants

Technical Information

R2 SERIES STANDARD OUTDOOR UNIT 20-32hp


MODEL REFERENCE PURY-P500YSHM-A PURY-P550YSHM-A PURY-P600YSHM-A PURY-P650YSHM-A PURY-P700YSHM-A PURY-P750YSHM-A PURY-P800YSHM-A
CAPACITY (kW) Heating (nominal) 63.0 69.0 76.5 81.5 88.0 95.0 100.0
Cooling (nominal) 56.0 63.0 69.0 73.0 80.0 85.0 90.0
Heating (UK) 54.8 60.0 66.6 70.9 75.7 81.7 86.0
Cooling (UK) 51.5 58.0 63.5 67.2 73.6 78.2 82.8
POWER INPUT (kW) Heating (nominal) 16.79 18.81 20.83 22.55 24.30 26.36 27.64
Cooling (nominal) 16.75 18.68 19.64 22.80 24.72 27.86 29.75
Heating (UK) 15.28 17.12 18.96 20.52 22.60 24.51 25.71
Cooling (UK) 11.73 13.08 13.75 15.96 17.80 20.06 21.42
COP/EER (nominal) 3.75 / 3.34 3.66 / 3.37 3.67 / 3.51 3.61 / 3.20 3.62 / 3.23 3.60 / 3.05 3.61 / 3.02
MAX No. OF CONNECTABLE INDOOR UNITS 50 50 50 50 50 50 50
AIRFLOW (m3/min) High 185 / 185 185 / 185 185 / 185 225 / 185 225 / 185 225 / 225 225 / 225
NOISE (dBA) 60 61 62 62.5 63 63.5 64
WEIGHT (kg) 235 + 235 240 + 235 240 + 240 265 + 240 265 + 240 265 + 265 265 + 265
DIMENSIONS (mm) Width 920 + 920 920 + 920 920 + 920 1220 + 920 1220 + 920 1220 + 1220 1220 + 1220
Depth 760 760 760 760 760 760 760
(1650mm without legs) Height 1710 1710 1710 1710 1710 1710 1710
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3 3 3 3
STARTING CURRENT (A) 8/8 8/8 8/8 8/8 8/8 8/8 8/8
RUNNING CURRENT (A) Heating 25.9 29.0 32.1 34.8 37.5 40.7 42.7
Cooling 25.8 28.8 30.3 35.2 38.2 43.0 45.9
FUSE RATING (MCB sizes BS EN 60947-2) - (A) 32 / 32 32 / 32 32 / 32 32 / 32 40 / 32 40 / 32 40 / 40
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

Note: For piping restrictions for PURY-P500-800YSHM-A please see page 158

Page 154
City Multi Range 2008
Dimensions

PURY-P500, 550, 600YSHM-A


Side View > Front View >

PURY-P650, 700YSHM-A
Side View > Front View >

PURY-P750, 800YSHM-A
Side View > Front View >
R2 Series Standard (20-32hp)

Page 155
R2 Series High COP (8-24hp)
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency


Throughout the year, many buildings require cooling in some areas and heating in
others - even in adjacent rooms. The outstanding City Multi R2 system meets this
requirement by distributing surplus heat from cooling operations (and vice versa)
to rooms where it is needed. This efficiency can result in energy savings of
up to 30% over conventional systems.

I Highest ever COP’s / EER’s due to new high efficiency


inverter technology and wrap around coil for added efficiency
I Up to 50 indoor units connected to each outdoor unit
I Easy to install unique 2-pipe technology means minimal
disruption, quicker installation and less connections
than a 3 pipe equivalents
I Weight and size reduction compared to previous YGM-A models
I Improved pipe run of 165m with a total system pipe length of up to 800m
I 100% inverter control with low start currents
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation
is achievable, the result being greater comfort for occupants

Technical Information

R2 SERIES HIGH COP OUTDOOR UNIT 8-24hp


MODEL REFERENCE PURY-EP200YHM-A PURY-EP300YHM-A PURY-EP400YSHM-A PURY-EP450YSHM-A PURY-EP500YSHM-A PURY-EP550YSHM-A PURY-EP600YSHM-A
CAPACITY (kW) Heating (nominal) 25.0 37.5 50.0 56.0 63.0 69.0 76.5
Cooling (nominal) 22.4 33.5 45.0 50.0 56.0 63.0 69.0
Heating (UK) 23.0 33.0 44.0 48.7 54.8 60.0 66.6
Cooling (UK) 21.3 31.5 42.3 46.0 51.5 58.0 63.5
POWER INPUT (kW) Heating (nominal) 5.81 9.37 11.73 13.77 15.33 17.37 19.12
Cooling (nominal) 5.23 8.33 10.57 13.09 13.70 16.38 17.00
Heating (UK) 5.75 9.09 11.38 12.53 13.95 15.81 17.40
Cooling (UK) 3.24 6.16 7.82 9.16 9.59 11.47 11.90
COP/EER (nominal) 4.30 / 4.28 4.00 / 4.02 4.26 / 4.25 4.06 / 3.81 4.10 / 4.08 3.97 / 3.84 4.00 / 4.05
MAX No. OF CONNECTABLE INDOOR UNITS 20 30 40 45 50 50 50
AIRFLOW (m3/min) High 185 225 185 / 185 185 / 185 225 / 185 225 / 185 225 / 225
NOISE (dBA) 57 60 60 60 62 62 63
WEIGHT (kg) 235 265 235 + 235 235 + 235 265 + 235 265 + 235 265 + 265
DIMENSIONS (mm) Width 920 1220 920 + 920 920 + 920 1220 + 920 1220 + 920 1220 + 1220
Depth 760 760 760 760 760 760 760
(1650mm without legs) Height 1710 1710 1710 1710 1710 1710 1710
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3 3 3 3
STARTING CURRENT (A) 8 8 8/8 8/8 8/8 8/8 8/8
RUNNING CURRENT (A) Heating 8.9 14.4 18.1 21.2 23.6 26.8 29.5
Cooling 8.0 12.8 16.3 20.2 21.1 25.3 26.2
FUSE RATING (MCB sizes BS EN 60947-2) - (A) 20 32 20 / 20 32 / 20 32 / 20 32 / 32 32 / 32
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

Note: For piping restrictions for PURY-EP200-600Y(S)HM-A please see page 158

Page 156
City Multi Range 2008
Dimensions

PURY-EP200, 300YHM-A
PURY-EP200YHM-A schematic is the same as PURY-P250, 300YHM-A on page 153
PURY-EP300YHM-A schematic is the same as PURY-P350, 400YHM-A on page 153

PURY-EP400, 450YSHM-A
Side View > Front View >

PURY-EP500, 550YSHM-A
Side View > Front View >

PURY-EP600YSHM-A
R2 Series High COP (8-24hp)

Side View > Front View >

Page 157
R2 Series Piping Restrictions

R2 SERIES PIPING RESTRICTIONS


TABLE 1: TOTAL PIPE LENGTH
OUTDOOR MODEL MAX LENGTH
P250, P300 550m*1
P350, P400, EP200, EP300 600m*1
P500, P550, EP400, EP450, EP500, EP550 750m*1
P600, P650, EP600 800m*1
P700, P750, P800 950m*1

*1 Please refer to Graph 1

GRAPH 1: TOTAL PIPING LENGTH RESTRICTIONS

1000

900
Total Extended Pipe Length (m)

800

700 PURY-P700,750,800 YSHM-A

600
PURY-P600,650,800 YSHM-A, PURY-EP600YSHM-A
500
PURY-P500,550 YSHM-A, PURY-EP400,450,500,550 YSHM-A

400
PURY-P350,400 YHM-A, PURY-EP200,300 YHM-A
300 PURY-P250,300YHM-A

200

100

0
10 20 30 40 50 60 70 80 90 100 110

Distance Between Outdoor Unit and BC Controller (m)

R2 SERIES PIPING RESTRICTIONS

R2 SERIES PIPING RESTRICTIONS


PIPING LENGTH (1 BC CONTROLLER, NO SUB BC CONTROLLER)
ITEM PIPE SECTION MAX LENGTH
Total Piping Length A+B+a+b+c+d (See Table 1)
Furthest Piping Length A+B+d 165m
Length Between OU and BC A 110m*1
Length Between Furthest IU and BC B+d 60m*2 (40m)
Height Between OU and IU (OU above IU) H 50m
Height Between OU and IU (OU below IU) H1 40m
Height Between IU and BC h1 15m
Height Between IU and IU h2 15m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

Page 158
City Multi Range 2008
R2 SERIES PIPING RESTRICTIONS
PIPING LENGTH (>1 BC CONTROLLER FOR 1 OUTDOOR UNIT)
ITEM PIPE SECTION MAX LENGTH
Total Piping Length A+B+C+D+E+a+b+c+d+e+f (See Table 1)
Furthest Piping Length A+C+E+f 165m
Length Between OU and BC A 110m*1
Length Between Furthest IU and BC B+d or C+D+e or C+E+f 60m*2 (40m)
Height Between OU and IU (OU above IU) H 50m
Height Between OU and IU (OU below IU) H1 40m
Height Between IU and BC h1 15m
Height Between IU and IU h2 15m
Height Between BC (Main or Sub) and BC (Sub) h3 15m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

R2 Series Piping Restrictions

R2 SERIES PIPING RESTRICTIONS


PIPING LENGTH (>1 BC CONTROLLER FOR 2 OUTDOOR UNITS)
ITEM PIPE SECTION MAX LENGTH
Total Piping Length F+G+A+B+C+D+E+a+b+c+d+e+f (See Table 1)
Furthest Piping Length F(G)+A+C+E+f 165m
Length Between OU and BC F(G)+A 110m*1
Length Between Furthest IU and BC B+d or C+D+e or C+E+f 60m*2 (40m)
Height Between OU and IU (OU above IU) H 50m
Height Between OU and IU (OU below IU) H1 40m
Height Between IU and BC h1 15m
Height Between IU and IU h2 15m
Height Between BC (Main or Sub) and BC (Sub) h3 15m
Length Between Main OU and Sub OU F+G or H 5m
Height Between Main OU and Sub OU h4 0.1m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

Page 159
WR2 Series (8-20hp)
Water Cooled Condensing Unit
Simultaneous Heating and Cooling with Double Heat Recovery
The WR2 system has double heat recovery potential, making this system very economical.
Not only does it produce heat recovery from indoor units on the same refrigerant circuit,
it also produces heat recovery via the water circuit between heat source units.

I All the benefits of the R2 Series with water cooled condensing units, using a single inverter compressor
I High COPs possible thanks to increased efficiency and careful control of the system,
allowing the largest operational water circuit temperature band ever
I Unique 2-pipe refrigerant circuit allows simultaneous heating and cooling
plus heat recovery between indoor units as with the R2 system
I Total building heat recovery made possible by exchanging energy in both
refrigerant and water circuits
I Combining WR2 with waste heat energy provides unique application solutions
I Condensing units can be situated indoors allowing greater design flexibility
and no limitation on building size
I Single inverter compressor up to 20hp
I Improved pipe run of 150m with a total system pipe length of up to 400m
I High Sensible Cooling Function - By raising the off coil temperature,
a 10% increase in sensible cooling capacity over standard operation is
achievable, the result being greater comfort for occupants
I Now able to operate with closed loop ground source water
temperatures, bore hole and slinky applications are now possible

Technical Information

WR2 SERIES HEAT SOURCE UNIT - 8-20hp


MODEL REFERENCE PQRY-P200YGM-A PQRY-P250YGM-A PQRY-P400YSGM-A PQRY-P500YSGM-A
CAPACITY (kW) Heating (nominal) 25.0 31.5 50.0 63.0
Cooling (nominal) 22.4 28.0 45.0 56.0
POWER INPUT (kW) Heating (nominal) 4.69 5.80 11.01 13.60
Cooling (nominal) 4.79 5.95 11.35 15.06
MAX No. OF CONNECTABLE INDOOR UNITS 15 19 24 24
NOISE (dBA) 46 47 50 53
WEIGHT (kg) 263 266 208 + 232 208 + 236
DIMENSIONS (mm) Width 990 990 1980 1980
Depth 550 550 550 550
Height 1800 1800 1800 1800
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3
STARTING CURRENT (A) 8 8 8 8
RUNNING CURRENT (A) Heating 7.2 8.9 17.0 21.0
Cooling 7.4 9.1 17.5 23.3
FUSE RATING (BS88) - HRC (A) 20 25 40 50
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth

PQRY-P200-500Y(S)GM-A Piping Restrictions


TOTAL PIPING LENGTH 400m max*3 (300m)
FURTHEST PIPING LENGTH 150m max
BETWEEN OUTDOOR AND BC CONTROLLER (MASTER) - LENGTH 110m max*4 (70m)
BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - LENGTH 60m max*5 (40m)
BETWEEN INDOOR AND OUTDOOR - HEIGHT 50m max (40m)*1
BETWEEN INDOOR AND INDOOR - HEIGHT 15m max (10m)*2
BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - HEIGHT 15m max
BETWEEN INDOOR (MASTER) AND INDOOR (SLAVE) - HEIGHT 15m max (10m)*2
*1 When O/U is below indoor *2 In case of P200, P250 indoor unit *3 Distance between outdoor unit and BC Controller is 70m or less *4 Total piping length is 300m or less
*5 Height difference between the Master BC Controller and furthest indoor unit is zero

Page 160
City Multi Range 2008
Dimensions

PQRY-P200, 250YGM-A
Upper View >

Left Side View >


Front View >

PQRY-P400, 500YSGM-A
Upper View >

Left Side View >


Front View >
WR2 Series (8-20hp)

Page 161
PFD-P-VM-E (10/20hp)
Heat Pump Close Control System
Mitsubishi Electric’s new Close Control System is specifically designed for computer rooms, laboratories etc, where
a need for high sensible cooling and close control of temperature and humidity is required. Because of the need for
close control 24 hours a day, 365 days a year, a newly developed inverter driven compressor has been incorporated
into the outdoor unit, maximising the energy efficiency of the PFD series.
It is also able to be connected to a computer network using our
G50 controller, in order to monitor and provide remote email alarms.
I High sensible cooling
I Newly developed inverter driven compressor
I Energy efficient with high COP’s
I Close control of temperature, ±1ºC
I Easy to install - no service space
needed at the rear of the unit
I Optional third party humidifier available
I Quick recovery following power failure
I Return or discharge air temperature control

Technical Information
PFD-P-VM-E - INDOOR UNIT PUHY-P-YHM-A / PQHY-P-YGM-A - OUTDOOR UNITS
MODEL REFERENCE PFD-P250VM-E PFD-P500VM-E PUHY-P250YHM-A PQHY-P250YGM-A PUHY-P250YHM-A x2 PQHY-P250YGM-A x2
CAPACITY (kW) Heating (nominal) 31.5 63.0 31.5 31.5 63.0 63.0
Cooling (nominal) 28.0 56.0 28.0 28.0 56.0 56.0
Heating (UK) 29.1 55.4 28.7 N/A 54.8 N/A
Cooling (UK) 26.6 51.5 26.6 N/A 51.5 N/A
SHF 0.93 0.93 N/A N/A N/A N/A
POWER INPUT (kW) Heating (nominal) 2.5 5.0 6.6 5.6 6.6 / 6.6 5.6 / 5.6
Cooling (nominal) 2.5 5.0 6.8 5.9 6.8 / 6.8 5.9 / 5.9
Heating (UK) 2.15 4.3 6.55 N/A 6.55 / 6.55 N/A
Cooling (UK) 2.15 4.3 4.2 N/A 4.2 / 4.2 N/A
AIRFLOW (m3/min) 160 320 185 N/A 185 / 185 N/A
EXTERNAL STATIC PRESSURE (Pa) 120 120 N/A N/A N/A N/A
PIPE SIZE mm(in) Gas 22.2 (7/8”) 28.58 (1 1/8”) 22.2 (7/8”) 22.2 (7/8”) 28.58 (1 1/8”) 28.58 (1 1/8”)
Liquid 9.52 (3/8”) 15.88 (5/8”) 9.52 (3/8”) 9.52 (3/8”) 15.88 (5/8”) 15.88 (5/8”)
NOISE (dBA) 59 63 57 47 57 / 57 47 / 47
WEIGHT (kg) 380 520 200 275 200 + 200 275 + 275
DIMENSIONS (mm) Width 1380 1980 920 990 920 + 920 990 + 990
Depth 780 780 760 550 760 550
Height 1950 1950 1710 1800 1710 1800
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE 3 3 3 3 3 3
STARTING CURRENT (A) Inverter / DOL 47 68 8 8 8/8 8/8
RUNNING CURRENT (A) Heating 4.9 8.7 10.2 8.5 10.2 / 10.2 8.5 / 8.5
Cooling 4.9 8.7 10.5 9.0 10.5 / 10.5 9.0 / 9.0
FUSE RATING (BS88) - HRC (A) 16 20 32 25 32 / 32 25 / 25
MAINS CABLE No. Cores 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth 4 + earth

PUHY-P-YHM-A / PQHY-P-YGM-A Piping Restrictions


TOTAL PIPING LENGTH 165m max (150m for PQHY)
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 50m max (40m max if outdoor installed below)

Page 162
City Multi Range 2008
Dimensions

PFD-P250VM-E

Upper View >

Side View >


Front View >

PFD-P500VM-E

Upper View >

Side View >


Front View >
PFD-P-VM-E (10/20hp)

Page 163
PLFY-P-VBM-E
2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to
4.2 meters in height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustable
vanes that allow users to precisely direct air where it’s needed.

The Mitsubishi Electric airflow control mechanism has been improved and uses wider vanes so that the unit reduces
drafts and smudging, whilst a high performance drain pump on the drain lift mechanism allows drain water to be
lifted up to 850mm from the ceiling surface.

I Handy corner pocket design simplifies maintenance


I Airflow controllable for ceiling heights up to 4.2m,
with automatic adjustment of fan speed
I Reduced draft air distribution, with independent vane control
I Drain pump as standard, 850mm from drain pan
I Filter lowering operation down to 4m
(optional PLP-6BAJ grille required)
I Optional ‘I See Sensor’ for energy saving and smooth
temperature control throughout the room
I For further information on the features of this cassette, please see page 60

Technical Information
PLFY-P-VBM-E - INDOOR UNIT
MODEL REFERENCE PLFY-P32VBM-E PLFY-P40VBM-E PLFY-P50VBM-E PLFY-P63VBM-E PLFY-P80VBM-E PLFY-P100VBM-E PLFY-P125VBM-E
CAPACITY (kW) Heating (nominal) 4.0 5.0 6.3 8.0 10.0 12.5 16.0
Cooling (nominal) 3.6 4.5 5.6 7.1 9.0 11.2 14.0
Heating (UK) 3.7 4.6 5.8 7.4 9.2 11.6 14.8
Cooling (UK) 3.2 4.0 5.0 6.3 8.0 10.0 12.5
High Sensible Cooling (UK) 2.6 3.3 4.1 5.2 6.5 8.1 10.2
SHF (UK) 0.84 0.83 0.76 0.75 0.73 0.73 0.71
High Sensible (UK) 0.96 0.91 0.83 0.79 0.78 0.79 0.74
POWER INPUT (kW) Heating (nominal) 0.02 0.03 0.03 0.04 0.06 0.14 0.15
Cooling (nominal) 0.03 0.04 0.04 0.05 0.07 0.15 0.16
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 11-12-13-14 12-13-14-16 12-13-14-16 14-15-16-18 16-18-20-22 21-24-27-29 22-25-28-30
NOISE (dBA) Lo-Mi1-Mi2-Hi 27-28-29-31 27-28-30-31 27-28-30-31 28-29-30-32 30-32-35-37 34-37-39-41 35-38-41-43
WEIGHT (kg) (Grille) 22(6) 22(6) 22(6) 23(6) 23(6) 27(6) 27(6)
DIMENSIONS (mm) Width (Grille) 840(950) 840(950) 840(950) 840(950) 840(950) 840(950) 840(950)
Depth (Grille) 840(950) 840(950) 840(950) 840(950) 840(950) 840(950) 840(950)
Height (Grille) 258(35) 258(35) 258(35) 258(35) 258(35) 298(35) 298(35)
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single Single Single
RUNNING CURRENT (A) Heating 0.14 0.22 0.22 0.29 0.43 0.94 1.00
Cooling 0.22 0.29 0.29 0.36 0.51 1.00 1.07
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6
MAINS CABLE No. Cores 3 3 3 3 3 3 3
GRILLE MODEL REFERENCE PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA PLP-6BA

Page 164
City Multi Range 2008
Dimensions

PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E

Upper View >

Lower View >

Side View >


PLFY-P-VBM-E

MODELS A B

PLFY-P32-80VBM-E 241 258

PLFY-P100-125VBM-E 281 298

Page 165
PLFY-P-VCM-E
600x600 4-Way Blow Ceiling Cassette Indoor Unit
The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm,
this lightweight unit makes installation a breeze. This unit also comes complete with
a long life filter that will last for approximately 2,500 hours.

I Compact size for handy installation and easy maintenance


I Only 208mm high
I Fresh air duct facility

Technical Information
PLFY-P-VCM-E - INDOOR UNIT
MODEL REFERENCE PLFY-P20VCM-E PLFY-P25VCM-E PLFY-P32VCM-E PLFY-P40VCM-E
CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0
Cooling (nominal) 2.2 2.8 3.6 4.5
Heating (UK) 2.3 3.0 3.7 4.6
Cooling (UK) 2.1 2.6 3.4 4.3
High Sensible Cooling (UK) 1.6 2.0 2.6 3.3
SHF (UK) 0.86 0.81 0.76 0.70
High Sensible (UK) 1.00 0.90 0.85 0.76
POWER INPUT (kW) Heating (nominal) 0.05 0.05 0.06 0.06
Cooling (nominal) 0.05 0.05 0.06 0.06
AIRFLOW (m3/min) Lo-Mi-Hi 8-9-10 8-9-10 8-9-11 8-9-11
NOISE (dBA) Lo-Mi-Hi 28-31-35 28-31-37 29-33-38 30-34-39
WEIGHT (kg) (Grille) 15.5(3) 15.5(3) 17(3) 17(3)
DIMENSIONS (mm) Width (Grille) 570(650) 570(650) 570(650) 570(650)
Depth (Grille) 570(650) 570(650) 570(650) 570(650)
Height (Grille) 208(20) 208(20) 208(20) 208(20)
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single
RUNNING CURRENT (A) Heating 0.23 0.23 0.28 0.28
Cooling 0.23 0.23 0.28 0.28
FUSE RATING (BS88) - HRC (A) 6 6 6 6
MAINS CABLE No. Cores 3 3 3 3
GRILLE MODEL REFERENCE SLP-2AA SLP-2AA SLP-2AA SLP-2AA

Page 166
City Multi Range 2008
Dimensions

PLFY-P20, 25, 32, 40VCM-E

Lower View >

Side View >


PLFY-P-VCM-E

Page 167
PLFY-P-VLMD-E
2-Way Blow Ceiling Cassette Indoor Unit
The PLFY-P-VLMD-E cassette unit fits into the space in a suspended ceiling to provide
heating or cooling. This new unit has been redesigned with lower unit height
and lower noise levels.

I Light unit for ease of installation


I Terminal block on outside of unit for easy wiring
I Drain lift-pump mechanism as standard
I Newly designed decoration panel with air flow
switching and swing functions as standard

Technical Information
PLFY-P-VLMD-E - INDOOR UNIT
MODEL REFERENCE PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY-
P20VLMD-E P25VLMD-E P32VLMD-E P40VLMD-E P50VLMD-E P63VLMD-E P80VLMD-E P100VLMD-E P125VLMD-E

CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0

Cooling (nominal) 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0

Heating (UK) 2.3 3.0 3.7 4.6 5.8 7.4 9.2 11.6 14.8

Cooling (UK) 2.1 2.6 3.4 4.3 5.3 6.7 8.5 10.6 13.2

High Sensible Cooling (UK) 1.6 2.0 2.6 3.3 4.1 5.2 6.5 8.1 10.2

SHF (UK) 0.81 0.77 0.74 0.67 0.70 0.72 0.71 0.73 0.73

High Sensible (UK) 0.94 0.85 0.81 0.73 0.73 0.77 0.77 0.79 0.80

POWER INPUT (kW) Heating (nominal) 0.065 0.065 0.065 0.074 0.075 0.094 0.140 0.150 0.27

Cooling (nominal) 0.072 0.072 0.072 0.081 0.082 0.101 0.147 0.157 0.28

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 6.5-8.0-9.5 6.5-8.0-9.5 6.5-8.0-9.5 7.0-8.5-10.5 9.0-11.0-12.5 10.0-13.0-15.5 15.5-18.5-22.0 17.5-21.0-25.0 24-27-30-33

NOISE (dBA) Lo-Mi1-Mi2-Hi 27-30-33 27-30-33 27-30-33 29-33-36 31-34-37 32-37-39 33-36-39 36-39-42 40-42-44-46

WEIGHT (kg) (Grille) 23(6.5) 23(6.5) 24(6.5) 24(6.5) 27(7.5) 28(7.5) 44(12.5) 47(12.5) 56(13)

DIMENSIONS (mm) Width (Grille) 776(1080) 776(1080) 776(1080) 776(1080) 946(1250) 946(1250) 1446(1750) 1446(1750) 1708(2010)

Depth (Grille) 634(710) 634(710) 634(710) 634(710) 634(710) 634(710) 634(710) 634(710) 606(710)

Height (Grille) 290(20) 290(20) 290(20) 290(20) 290(20) 290(20) 290(20) 290(20) 290(20)

ELECTRICAL SUPPLY 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v,

50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz

PHASE Single Single Single Single Single Single Single Single Single

RUNNING CURRENT (A) Heating 0.30 0.30 0.30 0.34 0.35 0.43 0.66 0.69 1.33

Cooling 0.36 0.36 0.36 0.40 0.41 0.49 0.72 0.75 1.35

FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6 6 6

MAINS CABLE No. Cores 3 3 3 3 3 3 3 3 3

GRILLE MODEL REFERENCE CMP- CMP- CMP- CMP- CMP- CMP- CMP- CMP- CMP-
40VLW-B 40VLW-B 40VLW-B 40VLW-B 63VLW-B 63VLW-B 100VLW-B 100VLW-B 125VLW-B

Page 168
City Multi Range 2008
Dimensions

PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E

Front View > Upper View >

Lower View >

Side View >

PLFY-P125VLMD-E

Side View > Upper View >

Rear View > Lower View >


PLFY-P-VLMD-E

Page 169
PMFY-P-VBM-E
1-Way Blow Ceiling Cassette Indoor Unit
Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited.
A total body weight of 14kg makes it one of the lightest available, latest fan technology also makes it
one of the quietest.

I Compact size for handy installation and easy maintenance

I Newly developed airflow control technology


reduces noise levels to only 27dBA

I Drain lift pump mechanism allows the drain to be positioned


anywhere up to 600mm from the ceiling’s surface

I Only 230mm high

I Fresh air duct facility

Technical Information
PMFY-P-VBM-E - INDOOR UNIT
MODEL REFERENCE PMFY-P20VBM-E PMFY-P25VBM-E PMFY-P32VBM-E PMFY-P40VBM-E
CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0
Cooling (nominal) 2.2 2.8 3.6 4.5
Heating (UK) 2.3 3.0 3.7 4.6
Cooling (UK) 2.1 2.6 3.4 4.3
High Sensible Cooling (UK) 1.6 2.0 2.6 3.3
SHF (UK) 0.81 0.77 0.71 0.70
High Sensible (UK) 0.94 0.90 0.77 0.76
POWER INPUT (kW) Heating (nominal) 0.042 0.044 0.044 0.054
Cooling (nominal) 0.042 0.044 0.044 0.054
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 6.5-7.2-8.0-8.7 7.3-8.0-8.6-9.3 7.3-8.0-8.6-9.3 7.7-8.7-9.7-10.7
NOISE (dBA) Lo-Mi1-Mi2-Hi 27-30-33-35 32-34-36-37 32-34-36-37 33-35-37-39
WEIGHT (kg) (Grille) 14(3) 14(3) 14(3) 14(3)
DIMENSIONS (mm) Width (Grille) 812(1000) 812(1000) 812(1000) 812(1000)
Depth (Grille) 395(470) 395(470) 395(470) 395(470)
Height (Grille) 230(30) 230(30) 230(30) 230(30)
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single
RUNNING CURRENT (A) Heating 0.20 0.21 0.21 0.26
Cooling 0.20 0.21 0.21 0.26
FUSE RATING (BS88) - HRC (A) 6 6 6 6
MAINS CABLE No. Cores 3 3 3 3
GRILLE MODEL REFERENCE PMP-40BM PMP-40BM PMP-40BM PMP-40BM

Page 170
City Multi Range 2008
Dimensions

PMFY-P20, 25, 32, 40VBM-E

Upper View >

Lower View >

Side View > Front View > PMFY-P-VBM-E

Page 171
PEFY-P-VMS1-E
Ultra Thin Ceiling Concealed Ducted Indoor Unit
The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularly
suitable for places where low noise operation is desired from a slimline body.

I Ultra thin body - height of only 200mm & width of only 790mm (P15-32)

I Extremely quiet operation - as low as 22dBA

I Cooling operation set temperature can be set down to 14°C db

I Static pressure of 5-50Pa

I Now available in a size 15, ideal for hotel rooms

Technical Information
PEFY-P-VMS1-E - INDOOR UNIT
MODEL REFERENCE PEFY-P15VMS1-E PEFY-P20VMS1-E PEFY-P25VMS1-E PEFY-P32VMS1-E PEFY-P40VMS1-E PEFY-P50VMS1-E PEFY-P63VMS1-E
CAPACITY (kW) Heating (nominal) 1.9 2.5 3.2 4.0 5.0 6.3 8.0
Cooling (nominal) 1.7 2.2 2.8 3.6 4.5 5.6 7.1
Heating (UK) 1.8 2.3 3.0 3.7 4.6 5.8 7.4
Cooling (UK) 1.5 2.0 2.5 3.2 4.0 5.0 6.3
High Sensible Cooling (UK) 1.2 1.6 2.0 2.6 3.3 4.1 5.2
SHF (UK) 0.93 0.85 0.84 0.78 0.75 0.74 0.75
High Sensible (UK) 1.00 1.00 0.90 0.85 0.82 0.78 0.79
POWER INPUT (kW) Heating (nominal) 0.03 0.03 0.04 0.05 0.05 0.07 0.07
Cooling (nominal) 0.05 0.05 0.06 0.07 0.07 0.09 0.09
AIRFLOW (m3/min) Lo-Mi-Hi 5.0-6.0-7.0 5.5-6.5-8.0 5.5-7.0-9.0 6.0-8.0-10.0 8.0-9.5-11.0 9.5-11.0-13.0 12.0-14.0-16.5
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Hi 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50
NOISE (dBA) (5Pa) Lo-Mi-Hi 22-24-28 23-25-29 24-26-30 24-27-32 28-30-33 30-32-35 30-33-36
WEIGHT (kg) 19 19 19 20 24 24 28
DIMENSIONS (mm) Width 790 790 790 790 990 990 1190
Depth 700 700 700 700 700 700 700
Height 200 200 200 200 200 200 200
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single Single Single
RUNNING CURRENT (A) Heating 0.31 0.36 0.39 0.39 0.45 0.56 0.61
Cooling 0.42 0.47 0.50 0.50 0.56 0.67 0.72
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6
MAINS CABLE No. Cores 3 3 3 3 3 3 3

Page 172
City Multi Range 2008
Dimensions

PEFY-P15, 20, 25, 32, 40, 50, 63 VMS1-E

Upper View >

Side View >

Front View >


PEFY-P-VMS1-E

Model A B C D E F
PEFY-P15-32VMS1-E 700 752 798 660 7 600
PEFY-P40-50VMS1-E 900 952 998 860 9 800
PEFY-P63VMS1-E 1100 1152 1198 1060 11 1000

Page 173
PEFY-P-VMM-E
Ceiling Concealed Ducted Indoor Unit
The PEFY-P-VMM-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive
air conditioning. Flexibility of duct layout allows air flow patterns to be arranged to suit any application.

I Reduced noise levels thanks to the use of a newly


designed centrifugal fan - as low as 27dBA

I Drain lift-pump (option), 550mm of lift

I Complete flexibility in air conditioning design

I Cooling operation set temperature can be set


down to 14ºC db

Technical Information

PEFY-P-VMM-E - INDOOR UNIT


MODEL REFERENCE PEFY- PEFY- PEFY- PEFY- PEFY- PEFY- PEFY- PEFY- PEFY-
P20VMM-E P25VMM-E P32VMM-E P40VMM-E P50VMM-E P63VMM-E P80VMM-E P100VMM-E P125VMM-E
CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0

Cooling (nominal) 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0

Heating (UK) 2.3 3.0 3.7 4.6 5.8 7.4 9.2 11.6 14.8

Cooling (UK) 2.1 2.6 3.4 4.3 5.3 6.7 8.5 10.6 13.2

High Sensible Cooling (UK) 1.6 2.0 2.6 3.3 4.1 5.2 6.5 8.1 10.2

SHF (UK) 0.86 0.77 0.76 0.77 0.75 0.75 0.72 0.78 0.77

High Sensible (UK) 0.94 0.85 0.85 0.85 0.83 0.81 0.78 0.88 0.85

POWER INPUT (kW) Heating (nominal) 0.15 0.15 0.17 0.19 0.20 0.22 0.25 0.29 0.40

Cooling (nominal) 0.15 0.15 0.17 0.19 0.20 0.22 0.25 0.29 0.40

AIRFLOW (m3/min) Lo-Mi-Hi 6.0-7.2-8.5 6.0-7.2-8.5 7.5-9.0-10.5 10-12-14 12.0-14.5-17.0 13.5-16.2-19.0 14.5-18.0-21.0 23-33 28-40

EXTERNAL STATIC PRESSURE (Pa) - Lo-Mi-Hi 30-50-100 30-50-100 30-50-100 30-50-100 30-50-100 30-50-100 30-50-100 50-130 50-130

NOISE (dBA) Lo-Mi-Hi 27-30-32 27-30-32 28-32-35 31-34-37 31-35-38 31-35-38 32-36-39 40-44 42-45

WEIGHT (kg) 27 27 27 33 33 42 42 62 65

DIMENSIONS (mm) Width 815 815 815 935 935 1175 1175 1415 1415

Depth 700 700 700 700 700 700 700 740 740

Height 295 295 295 295 295 295 295 325 325

ELECTRICAL SUPPLY 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v, 220-240v,

50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz

PHASE Single Single Single Single Single Single Single Single Single

RUNNING CURRENT (A) Heating 0.73 0.73 0.81 0.92 0.98 1.07 1.15 1.34 1.90

Cooling 0.73 0.73 0.81 0.92 0.98 1.07 1.15 1.34 1.90

FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6 6 6 6

MAINS CABLE No. Cores 3 3 3 3 3 3 3 3 3

Page 174
City Multi Range 2008
Dimensions

PEFY-P20, 25, 32, 40, 50, 63, 80VMM-E

Upper View >


Model A B C D E
PEFY-P20-32VMM-E 652 245 - 710 684
PEFY-P40-50VMM-E 772 305 - 830 804
PEFY-P63-80VMM-E 1012 280 290 1070 1044

Side View > Front View >

PEFY-P100, 125VMM-E
Upper View >
1252

370 360

370 360

1252

1284

1310

Side View > Front View >


PEFY-P-VMM-E

370 360

1252

Page 175
PEFY-P-VMH-E
High Static Pressure Ceiling Concealed Ducted Indoor Unit
With improved design flexibility as a result of increased external static pressure, the PEFY-P-VMH-E
allows authentic duct air conditioning within the strictest aesthetic confines.

I External static pressure of 200Pa

I Greater flexibility for duct extension, branching air outlet configuration

I Reduced noise levels thanks to the use of newly designed centrifugal fan

I Duct can be connected to intake side

I Drain lift-pump (option) 550mm of lift

I Cooling operation set temperature


can be set down to 14ºC db

Technical Information
PEFY-P-VMH-E - INDOOR UNIT
MODEL REFERENCE PEFY-P80VMH-E PEFY-P100VMH-E PEFY-P125VMH-E PEFY-P140VMH-E
CAPACITY (kW) Heating (nominal) 10.0 12.5 16.0 18.0

Cooling (nominal) 9.0 11.2 14.0 16.0

Heating (UK) 9.2 11.6 14.8 16.6

Cooling (UK) 8.5 10.6 13.2 15.1

High Sensible Cooling (UK) 6.5 8.1 10.2 11.6

SHF (UK) 0.74 0.80 0.74 0.74

High Sensible (UK) 0.83 0.91 0.81 0.82

POWER INPUT (kW) Heating (nominal) 0.32 0.48 0.48 0.48

Cooling (nominal) 0.32 0.48 0.48 0.48

AIRFLOW (m3/min) Lo-Hi 18-25 26.5-38.0 26.5-38.0 28-40

EXTERNAL STATIC PRESSURE (Pa) - Lo-Mi-Hi 100-150-200 100-150-200 100-150-200 100-150-200

NOISE (dBA) Lo-Hi 38-43 38-44 38-44 38-44

WEIGHT (kg) 50 70 70 70

DIMENSIONS (mm) Width 1000 1200 1200 1200

Depth 900 900 900 900

Height 380 380 380 380

ELECTRICAL SUPPLY 220-240v, 220-240v, 220-240v, 220-240v,

50Hz 50Hz 50Hz 50Hz

PHASE Single Single Single Single

RUNNING CURRENT (A) Heating 1.47 2.34 2.34 2.35

Cooling 1.47 2.34 2.34 2.35

FUSE RATING (BS88) - HRC (A) 6 6 6 6

MAINS CABLE No. Cores 3 3 3 3

Page 176
City Multi Range 2008
Dimensions

PEFY-P80, 100, 125, 140VMH-E

Upper View >

Side View >

PEFY-P-VMH-E

Page 177
PCFY-P-VGM-E
Ceiling Suspended Indoor Unit
Designed for ultra-quiet operation and easy maintenance, the unit provides comfor table air conditioning
for a wide range of applications where floor or wall space cannot be used practically.

I Indoor unit designed for direct ceiling suspension

I Flush to wall installation for concealment of service connections

I Drain piping can be connected from left or right

Technical Information
PCFY-P-VGM-E - INDOOR UNIT
MODEL REFERENCE PCFY-P40VGM-E PCFY-P63VGM-E PCFY-P100VGM-E PCFY-P125VGM-E
CAPACITY (kW) Heating (nominal) 5.0 8.0 12.5 16.0
Cooling (nominal) 4.5 7.1 11.2 14.0
Heating (UK) 4.6 7.4 11.6 14.8
Cooling (UK) 4.3 6.7 10.6 13.2
High Sensible Cooling (UK) 3.3 5.2 8.1 10.2
SHF (UK) 0.72 0.72 0.71 0.70
High Sensible (UK) 0.79 0.79 0.77 0.76
POWER INPUT (kW) Heating (nominal) 0.10 0.13 0.16 0.24
Cooling (nominal) 0.10 0.13 0.16 0.24
AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 8-10-11-12 12-14-16-18 18-20-23-25 26-28-32-35
NOISE (dBA) Lo-Mi1-Mi2-Hi 29-33-36-38 32-34-37-39 36-38-41-43 37-39-42-44
WEIGHT (kg) 27 34 37 43
DIMENSIONS (mm) Width 1000 1310 1310 1620
Depth 680 680 680 680
Height 210 210 270 270
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single
RUNNING CURRENT (A) Heating 0.46 0.60 0.73 1.10
Cooling 0.46 0.60 0.73 1.10
FUSE RATING (BS88) - HRC (A) 6 6 6 6
MAINS CABLE No. Cores 3 3 3 3

Page 178
City Multi Range 2008
Dimensions

PCFY-P40, 63, 100, 125VGM-E

Upper View >

Front View >

Lower View >

PCFY-P-VGM-E

Page 179
PKFY-P-VBM-E/VGM-E/VFM-E
Wall Mounted Indoor Units
An elegant design combined with compact dimensions and quiet operation
make the PKFY-P an ideal unit choice. Noise levels are significantly reduced
thanks to a unique airflow passage design that not only makes the unit one
of the quietest in the industry, but also suppresses condensation
and prevents mixing with secondary air.

I Compact design - only 815mm wide (VBM-E)

I Front grille opening for easy cleaning

I Front power supply for easy wiring after installation

I 5-way piping provides more flexibility


in selection of installation sites

Technical Information
PKFY-P-VBM-E / VGM-E / VFM-E - INDOOR UNIT
MODEL REFERENCE PKFY-P20VBM-E PKFY-P25VBM-E PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E PKFY-P63VFM-E
CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0 6.3 8.0

Cooling (nominal) 2.2 2.8 3.6 4.5 5.6 7.1

Heating (UK) 2.3 3.0 3.7 4.6 5.8 7.4

Cooling (UK) 2.1 2.6 3.4 4.3 5.3 6.7

High Sensible Cooling (UK) 1.6 2.0 2.6 3.3 4.1 5.2

SHF (UK) 0.71 0.73 0.79 0.74 0.72 0.78

High Sensible (UK) 0.75 0.80 0.88 0.82 0.78 0.85

POWER INPUT (kW) Heating (nominal) 0.04 0.04 0.07 0.07 0.07 0.12

Cooling (nominal) 0.04 0.04 0.07 0.07 0.07 0.12

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 4.9-5.2-5.6-5.9 4.9-5.2-5.6-5.9 8.0-9.5-10.5-11.5 8.0-9.5-10.5-11.5 9-10-11-12 15-20

NOISE (dBA) Lo-Mi1-Mi2-Hi 29-31-34-36 29-31-34-36 33-36-38-41 33-36-38-41 34-37-40-43 39-45

WEIGHT (kg) 10 10 16 16 16 24

DIMENSIONS (mm) Width 815 815 990 990 990 1400

Depth 225 225 235 235 235 235

Height 295 295 340 340 340 340

ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz

PHASE Single Single Single Single Single Single

RUNNING CURRENT (A) Heating 0.20 0.20 0.32 0.32 0.32 0.55

Cooling 0.20 0.20 0.32 0.32 0.32 0.55

FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6

MAINS CABLE No. Cores 3 3 3 3 3 3

Page 180
City Multi Range 2008
Dimensions

PKFY-P20, 25VBM-E

Front View > Right Side View >

PKFY-P32, 40, 50VGM-E

Front View > Right Side View >

PKFY-P-VBM-E / PKFY-P-VGM-E / PKFY-P-VFM-E


PKFY-P63VFM-E

Front View > Right Side View >

Page 181
PFFY-P-VLRM-E
Floor Standing Concealed Indoor Unit
A compact concealed unit providing simple, effective air conditioning
in perimeter zones. The unit is easy to install and at only
220mm deep offers an unobtrusive method of delivering
highly efficient air-conditioning performance.

I Concealed unit for hidden installation

I Ideal for perimeter refurbishments

I Cooling operation set temperature can be


set down to 14ºC db

Technical Information

PFFY-P-VLRM-E - INDOOR UNIT


MODEL REFERENCE PFFY-P20VLRM-E PFFY-P25VLRM-E PFFY-P32VLRM-E PFFY-P40VLRM-E PFFY-P50VLRM-E PFFY-P63VLRM-E

CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0 6.3 8.0

Cooling (nominal) 2.2 2.8 3.6 4.5 5.6 7.1

Heating (UK) 2.3 3.0 3.7 4.6 5.8 7.4

Cooling (UK) 2.1 2.6 3.4 4.3 5.3 6.7

High Sensible Cooling (UK) 1.7 2.0 2.6 3.3 4.1 5.2

SHF (UK) 0.90 0.81 0.74 0.72 0.74 0.73

High Sensible (UK) 1.00 0.95 0.81 0.79 0.80 0.79

POWER INPUT (kW) Heating (nominal) 0.04 0.04 0.06 0.065 0.085 0.10

Cooling (nominal) 0.04 0.04 0.06 0.065 0.085 0.10

AIRFLOW (m3/min) Lo-Hi 5.5-6.5 5.5-6.5 7-9 9-11 12-14 12-15.5

NOISE (dBA) Lo-Hi 34-40 34-40 35-40 38-43 38-43 40-46

WEIGHT (kg) 18.5 18.5 20 21 25 27

DIMENSIONS (mm) Width 886 886 1006 1006 1246 1246

Depth 220 220 220 220 220 220

Height 639 639 639 639 639 639

ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz

PHASE Single Single Single Single Single Single

RUNNING CURRENT (A) Heating 0.19 0.19 0.29 0.32 0.40 0.46

Cooling 0.19 0.19 0.29 0.32 0.40 0.46

FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6

MAINS CABLE No. Cores 3 3 3 3 3 3

Page 182
City Multi Range 2008
Dimensions

PFFY-P20, 25, 32, 40, 50, 63VLRM-E

Upper View >

Front View >

Side View >

PFFY-P-VLRM-E

Page 183
PFFY-P-VLRMM-E
Floor Standing Concealed Indoor Unit
A compact concealed unit providing simple, effective air conditioning in perimeter zones.
The unit is easy to install and at only 220mm deep offers an unobtrusive method of
delivering highly efficient air-conditioning performance.

I Reduced noise levels compared to


the PFFY-P-VLRM-E version

I Cooling operation set temperature


can be set down to 14ºC db

I Static pressure. The new unit has 3 static pressure settings


- 20/40/60Pa ideal for ducting in the perimeter zone

I Concealed unit for hidden installation. The unit can be hidden


behind a wardrobe in a hotel, then ducted above and below
the wardrobe doors. This offers lower noise, less
disruption and a low visual impact

Technical Information
PFFY-P-VLRMM-E - INDOOR UNIT
MODEL REFERENCE PFFY-P20VLRMM-E PFFY-P25VLRMM-E PFFY-P32VLRMM-E PFFY-P40VLRMM-E PFFY-P50VLRMM-E PFFY-P63VLRMM-E
CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0 6.3 8.0
Cooling (nominal) 2.2 2.8 3.6 4.5 5.6 7.1
Heating (UK) 2.3 3.0 3.7 4.6 5.8 7.4
Cooling (UK) 2.0 2.5 3.2 4.0 5.0 6.3
High Sensible Cooling (UK) 1.6 2.0 2.6 3.3 4.1 5.2
SHF (UK) 0.80 0.76 0.75 0.75 0.76 0.73
High Sensible (UK) 0.88 0.80 0.81 0.79 0.80 0.79
POWER INPUT (kW) Heating (nominal) 0.04 0.04 0.04 0.05 0.05 0.07
Cooling (nominal) 0.04 0.04 0.04 0.05 0.05 0.07
AIRFLOW (m3/min) Lo-Mi-Hi 4.5-5.5-6.5 4.5-5.5-6.5 6.5-7.5-9 8-9.5-11 10-12-14 11-13-15.5
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Hi 20-40-60 20-40-60 20-40-60 20-40-60 20-40-60 20-40-60
NOISE (dBA) (20Pa) Lo-Mi-Hi 31-36-40 31-36-40 27-32-37 30-36-40 32-37-41 35-40-44
WEIGHT (kg) 18.5 18.5 20 21 25 27
DIMENSIONS (mm) Width 886 886 1006 1006 1246 1246
Depth 220 220 220 220 220 220
Height 639 639 639 639 639 639
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single Single
RUNNING CURRENT (A) Heating 0.34 0.34 0.38 0.43 0.48 0.59
Cooling 0.34 0.34 0.38 0.43 0.48 0.59
FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6
MAINS CABLE No. Cores 3 3 3 3 3 3

Page 184
City Multi Range 2008
Dimensions

PFFY-P20, 25, 32, 40, 50, 63VLRMM-E

Upper View >

Front View >

Side View >


PFFY-P-VLRMM-E

Page 185
PFFY-P-VLEM-E
Floor Standing Exposed Indoor Unit
A compact cased unit providing simple, effective air conditioning
in perimeter zones. The unit is easy to install, and at only 220mm
deep offers an unobtrusive method of delivering a highly
efficient air-conditioning performance.

I Remote controller can be incorporated into the main unit

I Cooling operation set temperature can be


set down to 14ºC db

Technical Information
PFFY-P-VLEM-E - INDOOR UNIT
MODEL REFERENCE PFFY-P20VLEM-E PFFY-P25VLEM-E PFFY-P32VLEM-E PFFY-P40VLEM-E PFFY-P50VLEM-E PFFY-P63VLEM-E

CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0 6.3 8.0

Cooling (nominal) 2.2 2.8 3.6 4.5 5.6 7.1

Heating (UK) 2.3 3.0 3.7 4.6 5.8 7.4

Cooling (UK) 2.1 2.6 3.4 4.3 5.3 6.7

High Sensible Cooling (UK) 1.7 2.0 2.6 3.3 4.1 5.2

SHF (UK) 0.90 0.81 0.74 0.72 0.74 0.73

High Sensible (UK) 1.00 0.95 0.81 0.79 0.80 0.79

POWER INPUT (kW) Heating (nominal) 0.04 0.04 0.06 0.065 0.085 0.10

Cooling (nominal) 0.04 0.04 0.06 0.065 0.085 0.10

AIRFLOW (m3/min) Lo-Hi 5.5-6.5 5.5-6.5 7-9 9-11 12-14 12-15.5

NOISE (dBA) Lo-Hi 34-40 34-40 35-40 38-43 38-43 40-46

WEIGHT (kg) 23 23 25 26 30 32

DIMENSIONS (mm) Width 1050 1050 1170 1170 1410 1410

Depth 220 220 220 220 220 220

Height 630 630 630 630 630 630

ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz

PHASE Single Single Single Single Single Single

RUNNING CURRENT (A) Heating 0.19 0.19 0.29 0.32 0.40 0.46

Cooling 0.19 0.19 0.29 0.32 0.40 0.46

FUSE RATING (BS88) - HRC (A) 6 6 6 6 6 6

MAINS CABLE No. Cores 3 3 3 3 3 3

Page 186
City Multi Range 2008
Dimensions

PFFY-P20,25,32,40,50,63VLEM-E

Upper View >

Front View >

Side View >

PFFY-P-VLEM-E

Page 187
PFFY-P-VKM-E
Floor Standing Exposed Indoor Unit
The PFFY-P-VKM-E series is extremely versatile and is designed for
wall attached installation at floor level. The auto swing vane provides
a more natural and comfortable airflow throughout the room and
the lightweight, compact design makes installation easy.

I Pure white, slimline design

I Upper and lower vanes for optimum,


powerful and efficient air distribution

Technical Information

PFFY-P-VKM-E - INDOOR UNIT


MODEL REFERENCE PFFY-P20VKM-E PFFY-P25VKM-E PFFY-P32VKM-E PFFY-P40VKM-E

CAPACITY (kW) Heating (nominal) 2.5 3.2 4.0 5.0

Cooling (nominal) 2.2 2.8 3.6 4.5

Heating (UK) 2.3 3.0 3.7 4.6

Cooling (UK) 2.1 2.6 3.4 4.3

High Sensible Cooling (UK) 1.6 2.0 2.6 3.3

SHF (UK) 0.81 0.77 0.71 0.70

High Sensible (UK) 0.88 0.85 0.77 0.76

POWER INPUT (kW) Heating (nominal) 0.025 0.025 0.025 0.028

Cooling (nominal) 0.025 0.025 0.025 0.028

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi 5.9-6.8-7.6-8.7 6.1-7.0-8.0-9.1 6.1-7.0-8.0-9.1 8.0-9.0-9.5-10.7

NOISE (dBA) Lo-Mi1-Mi2-Hi 27-31-34-37 28-32-35-38 28-32-35-38 35-38-42-44

WEIGHT (kg) 15 15 15 15

DIMENSIONS (mm) Width 700 700 700 700

Depth 200 200 200 200

Height 600 600 600 600

ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz

PHASE Single Single Single Single

RUNNING CURRENT (A) Heating 0.20 0.20 0.20 0.24

Cooling 0.20 0.20 0.20 0.24

FUSE RATING (BS88) - HRC (A) 6 6 6 6

MAINS CABLE No. Cores 3 3 3 3

Page 188
City Multi Range 2008
Dimensions

PFFY-P20,25,32,40VKM-E

Upper View >

Front View >

Side View > PFFY-P-VKM-E

Page 189
GUF-50RD3 & GUF100RD3
Lossnay Outdoor Air Processing Indoor Unit
The GUF-50RD3 and GUF-100RD3 outdoor air processing units can be used with any
of the extensive range of City Multi indoor units to provide ventilation, dust removal,
humidification and heat recovery.

I A combination of a Lossnay & City Multi indoor in a single unit

I Air temperature in any room can be adjusted to the desired temperature via
this unit which is used as an indoor unit of the City Multi air conditioning system

I The ventilating and air conditioning functions are


integrated in a single unit, saving space and installation costs

I Heat recovery helps to save energy - a benefit that’s not only good
for the environment, but also great for cutting energy costs

I Free cooling is also available should outdoor conditions be suitable

Technical Information
OUTDOOR AIR PROCESSING INDOOR UNIT
MODEL REFERENCE GUF-50RD3 GUF-100RD3
CAPACITY (kW) Heating (nominal) 6.42 (2.25) 13.00 (4.70)
Cooling (nominal) 5.29 (1.66) 10.81 (3.49)
Heating (UK) 5.93 (2.08) 12.01 (4.34)
Cooling (UK) 5.03 (1.58) 10.27 (3.32)
POWER INPUT (kW) 0.265 0.505
AIRFLOW (m3/h) Lo-Hi 400-500 800-1000
NOISE (dBA) Lo-Hi 29.5-34.5 34-39
WEIGHT (kg) 54 92
DIMENSIONS (mm) Width 1016 1231
Depth 1288 1580
Height 317 398
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single
RUNNING CURRENT (A) Lo-Hi 0.70-1.15 1.73-2.20
FUSE RATING (BS88) - HRC (A) 6 6
MAINS CABLE No. Cores 3 3

Attention
1. Nominal Condition:
Cooling/Heating capacity indicates the value of operation under the
following air condition and above air volume.
Cooling: Indoor 27ºC DB/19.5ºC WB, Outdoor 35ºC DB/24ºC WB.
Heating: Indoor 21ºC DB/14.6ºC WB, Outdoor 7ºC DB/6ºC WB.

2. UK Condition:
Summer: Indoor 21ºC, Outdoor 27ºC
Winter: Indoor 21ºC, Outdoor -1ºCWB
3. The figures in ( ) indicates the heat recovery at Lossnay core.
4. The current, input and efficiency are based on the above air volume.
5. The air nozzle noise (45º angle 1.5m ahead) is about 6dB
greater than the indicated value. (High notch).
6. Specifications may be subject to change without notice.

Page 190
City Multi Range 2008
Dimensions

GUF-50/100RD3

Side View >

Upper View >

Front View >


GUF-50RD3 and GUF100RD3

Page 191
PQFY-P
VRF Heat Pump Boiler
It is well known in the air conditioning industry that heat pumps are proven to provide highly efficient cooling. However,
in line with other forward-thinking countries, such as Sweden and Switzerland, Mitsubishi Electric have now designed a
heat pump boiler to provide heating and hot water, suitable for underfloor heating or swimming pools. Heat pump
technology is largely untapped and offers great potential with incredible design flexibility, excellent use of energy and
greatly reduced CO2 emissions.

An overview of the use of Heat Pump Boilers


The cooling operation of an air conditioning system that effectively extracts heat from a space, will normally be achieved at
between 3.5 to 4.0 COP. This in itself is an efficient system. However, by recovering that heat and using it to heat up water
the efficiency of the system increases dramatically to over 6.0 COP. Without the use of a Heat Pump Boiler, these levels of
efficiency are rarely achieved in Spring and Autumn, when different rooms may need heating and cooling from the air
conditioning at the same time.

By using the VRF Heat Pump Boiler in a permanent heat recovery application, these
efficiencies are now possible all year round. This provides a reduction in running
costs and CO2 emissions, both of which play a crucial role when obtaining
planning permission as covered by the new Part L2 Legislation.

There is a further reduction in capital costs as there is very little or no requirement


for gas boilers and associated works. Particularly when the small amount of heating
required in order to boost domestic hot water from the 45ºC (produced by the
heat pump), to the required 60ºC supply temperature, can be provided by means
of electric. Thus negating the need for the installation of a gas supply entirely.

Technical Information
PQFY-P
MODEL REFERENCE PQFY-P140 PQFY-P250
CAPACITY (kW) Heating (nominal) 14.0 25.0
PIPE SIZE mm(in) Gas Refrigerant 15.88 (5/8”) 19.05 (3/4”)
Liquid Refrigerant 9.52 (3/8”) 9.52 (3/8”)
Water 22 28
WEIGHT (kg) 32 50
DIMENSIONS (mm) Width 500 610
Depth 410 510
Height 560 560
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single
MAINS CABLE No. Cores 3 3

Unit Flow Rate & Pressure Drop


For calculating the Water Flow Rate please use the following calculation:
Capacity (kW) = Flow Rate of Water (l/s) x Specific Heat Capacity of Water x (Outlet Water Temp(ºC) - Inlet Water Temp (ºC))
Specific Heat Capacity of water is normally 4.2Kj/KgK

PQFY-P140
Flow Rate l/s 0.38 0.45 0.53 0.61 0.68 0.76 0.83
Pressure Drop kPA 11.72 15.86 20.69 25.51 30.34 36.54 42.75

PQFY-P250
Flow Rate l/s 0.61 0.76 0.91 1.06 1.21 1.36 1.52
Pressure Drop kPA 14.48 20.69 27.58 35.16 44.13 53.09 62.06

Note: The water flow rate can be above or below these values, but no pressure drop operating data can be provided.

Page 192
City Multi Range 2008
Dimensions

PQFY-P140

Front View > Upper View >


Front control panel not shown

PQFY-P250

Front View > Upper View >


Front control panel not shown

PQFY-P

Page 193
BC Controllers
At the heart of both the R2 and WR2 Series, the BC controller makes simultaneous heating and cooling possible.
It has the inherent ‘intelligence’ to be the system’s decision-maker.

I Transferring energy around the system


I Drawing on energy from the heat source units/outdoor units
I Directing energy as requested by the individual indoor units
I Instructs the heat source unit/outdoor unit on the amount
of refrigerant (liquid or gas) that is required to achieve
the requested cooling or heating requirements
I Allows unique 2-pipe heat recovery application
I HIC Circuit for improved efficiency

Technical Information
BC CONTROLLERS
MODEL REFERENCE CMB-P104V-G CMB-P105V-G CMB-P106V-G
NUMBER OF CONNECTIONS 4 5 6
WEIGHT (kg) 24 27 29
DIMENSIONS (mm) Width 648 648 648
Depth 362 + 70 362 + 70 362 + 70
Height 284 284 284
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single
POWER INPUT (KW) 0.085 0.104 0.123
RUNNING CURRENT (A) 0.36 0.44 0.52
FUSE RATING (BS88) – HRC (A) 6 6 6
MAINS CABLE No. Cores 3 3 3

Note: CMB-P-V-G units are for use with PURY-(E)P200-350 YHM-A & PQRY-P200/250YGM-A outdoor units only.

MASTER BC CONTROLLERS
MODEL REFERENCE CMB-P108V-GA CMB-P1010V-GA CMB-P1013V-GA CMB-P1016V-GA CMB-P1016V-HA
NUMBER OF CONNECTIONS 8 10 13 16 16
WEIGHT (kg) 44 49 57 64 73
DIMENSIONS (mm) Width 1110 1110 1110 1110 1110
Depth 450 + 70 450 + 70 450 + 70 450 + 70 450 + 70
Height 289 289 289 289 289
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single
POWER INPUT (KW) 0.161 0.198 0.255 0.312 0.312
RUNNING CURRENT (A) 0.68 0.83 1.07 1.30 1.30
FUSE RATING (BS88) – HRC (A) 6 6 6 6 6
MAINS CABLE No. Cores 3 3 3 3 3

Note: CMB-P-V-GA units are for use with PURY-(E)P200-650Y(S)HM-A & PQRY-P200-500YSGM-A outdoor units only. CMB-P1016V-HA unit is for use with PURY-P700-800YSHM-A outdoor units only.

SLAVE BC CONTROLLERS
MODEL REFERENCE CMB-P104V-GB CMB-P108V-GB CMB-P1016V-HB
NUMBER OF CONNECTIONS 4 8 16
WEIGHT (kg) 22 32 57
DIMENSIONS (mm) Width 648 648 1098
Depth 362 + 70 362 + 70 362 + 70
Height 284 284 284
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single
POWER INPUT (KW) 0.076 0.151 0.301
RUNNING CURRENT (A) 0.32 0.63 1.26
FUSE RATING (BS88) – HRC (A) 6 6 6
MAINS CABLE No. Cores 3 3 3

Note: CMB-P1016V-HB can be connected to a CMB-P1016V-HA.

Page 194
City Multi Range 2008
Dimensions

CMB-P104, 105, 106V-G

Upper View > Side View >

CMB-P108, 1010, 1013, 1016V-GA/HA

Upper View > Side View >

CMB-P104, 108V-GB

Upper View > Side View >

A B
CMB-P104V-GB 3 180
CMB-P108V-GB 3 420

CMB-P1016V-HB

Upper View > Side View >


BC Controllers

Page 195
PAC-AH-M-G/H Heat Pump & Cooling Only
Air Handling Unit Controller
The Air Handling Unit Controllers are an interface to allow
connection to third party manufacturer equipment.
Mitsubishi Electric City Multi outdoor units can be used
with this interface box, creating an ideal solution when a
unique air handling unit is required. The Air Handling Unit
Controllers are supplied with LEV expansion device(s).

Technical Information

PAC-AH-M-H - HEAT PUMP AHU CONTROLLER


MODEL REFERENCE PAC-AH125M-H PAC-AH125M-H PAC-AH140M-H PAC-AH250M-H PAC-AH250M-H
MITSUBISHI ELECTRIC OUTDOOR UNIT PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A
AIR HANDLING UNIT SIZE P100 P125 P140 P200 P250
ALLOWED EVAPORATOR CAPACITY (kW) - Heating 10.0 - 12.5 12.5 - 16.0 16.0 - 18.0 18.0 - 25.0 25.0 - 31.5
ALLOWED EVAPORATOR CAPACITY (kW) - Cooling 9.0 - 11.2 11.2 - 14.0 14.0 - 16.0 16.0 - 22.4 22.4 - 28.0
ALLOWED EVAPORATOR VOLUME (cm3) 1500 - 2850 1900 - 3550 2150 - 4050 3000 - 5700 3750 - 7100
STANDARD EVAPORATOR PATH NUMBER* 4 - 5 4 - 5 5 - 6 6 - 10 8 - 10
DIMENSIONS (mm) Width 326 326 326 326 326
( ) = Inc Mountings Depth 117 (132) 117 (132) 117 (132) 117 (132) 117 (132)
Height 410 (430) 410 (430) 410 (430) 410 (430) 410 (430)
WEIGHT (kg) 7 7 7 7 7

PAC-AH-M-G - COOLING ONLY AHU CONTROLLER


MODEL REFERENCE PAC-AH140M-G PAC-AH250M-G PAC-AH250M-G
MITSUBISHI ELECTRIC OUTDOOR UNIT PU(H)(R)Y-(E)P200-1250Y(S)HM-A PU(H)(R)Y-(E)P200-1250Y(S)HM-A PU(H)(R)Y-(E)P200-1250Y(S)HM-A
AIR HANDLING UNIT SIZE P140 P200 P250
ALLOWED EVAPORATOR CAPACITY (kW) 11.2 - 16.0 15.9 - 22.4 18.7 - 28.0
ALLOWED EVAPORATOR VOLUME (cm3) 2150 - 4050 3000 - 5700 3750 - 7100
STANDARD EVAPORATOR PATH NUMBER* 5 - 6 6 - 10 8 - 10
DIMENSIONS (mm) Width 326 326 326
( ) = Inc Mountings Depth 117 (132) 117 (132) 117 (132)
Height 382 (420) 382 (420) 382 (420)
WEIGHT (kg) 7 7 7

Note: One air handling unit controller is required per air handling unit
Saturated refrigerant temperature at exit of evaporator = 8.5ºC, SH=5K, liquid temperature = 25ºC, air = 27ºCDB/19ºCWB
*When the diameter of the heat exchanger tube is ø9.52

Air Handling Unit Controller Controller (field supplied)


Example: (Mitsubishi Electric)

220-240v, 50Hz
Power Supply

M-NET wiring Thermistor wiring

Piping

Outdoor Unit (Mitsubishi Electric) Air Handling Unit (field supplied)

Page 196
City Multi Range 2008
Accessories / Optional Extras

Outdoor Units CMY-Y102S-G2 - Branch Pipe (Joint) for size 200 or below - total capacity of indoor units
CMY-Y102L-G2 - Branch Pipe (Joint) for size 201-400 - total capacity of indoor units
CMY-Y202-G2 - Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of P500-P650
CMY-Y302-G2 - Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250
CMY-Y62-G-E - Branch Pipe for 2 branches (PUMY)
CMY-Y100VBK2 - Twinning Kit for PUHY-P500-650YSHM-A / PUHY-EP400-650YSHM-A
CMY-Y200VBK2 - Twinning Kit for PUHY-P700-900YSHM-A
CMY-Y300VBK2 - Twinning Kit for PUHY-P950-1250YSHM-A / PUHY-EP700-900YSHM-A
CMY-R100VBK - Twinning Kit for PURY-P500-650YSHM-A / PURY-EP400-600YSHM-A
CMY-R200VBK - Twinning Kit for PURY-P700-800YSHM-A
ACH1 - PQFY Auto-Changeover controller
ACOUSTIC KIT - Acoustic kits for PUHY and PURY units

4-Way Blow Cassette Units PLP-6BA - Grille for PLFY-P-VBM-E


SLP-2AA - Grille for PLFY-P-VCM-E
PLP-6BALM - Grille and infra-red controller for PLFY-P-VBM-E
PLP-6BAJ - Grille with filter lowering function for PLFY-P-VBM-E
PAC-SA1ME-E - ‘I -See Sensor’ corner panel for PLFY-P-VBM-E
PAR-SA9FA-E - Infra-red signal receiver for PLFY-P-VBM-E
S70E40714 - Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E

2-Way Blow Cassette Units CMP-P40VLW-B - Grille for PLFY-P20-40VLMD-E


CMP-P63VLW-B - Grille for PLFY-P50-63VLMD-E
CMP-P100VLW-B - Grille for PLFY-P80-100VLMD-E
CMP-P125VLW-B - Grille for PLFY-P125VLMD-E
PAC-KH11OF - OA duct flange for PLFY-P20-100VLMD-E

1-Way Blow Cassette Units PMP-40BM - Grille for PMFY-P-VBM-E

Ceiling Concealed Ducted Units PAC-KE03DM-F - Drain lift-up mechanism for PEFY-P-VMM-E
PAC-KE04DM-F - Drain lift-up mechanism for PEFY-P-VMH-E
PAC-KE88LAF - Long life filter for PEFY-P80VMH-E
PAC-KE89LAF - Long life filter for PEFY-P100-140VMH-E
PAC-KE80TB-F - Filter box for PEFY-P80VMH-E (necessary when long life filter is used)
PAC-KE140TB-F - Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used)

Air Handling Unit Controllers / Accessories


BC Controllers CMY-R160-J - Joint pipe
CMY-Y102S-G - Branch pipe

Indoor Units PAC-SE41TS-E - Remote sensor

Page 197
Lossnay
Total Heat Exchangers
Stale exhaust air
Heat exchange unit
(Lossnay core)
Fresh air from outside

Stale room air extracted

Fresh air supply to the room

Simple and
Excellent air quality
and unbeatable
Heat Exchange Efficiency
Poor air quality can be attributed to many problems arising in the workplace or in
the home. It is believed to contribute to a significant loss in productivity, low morale
and higher rates of sickness amongst many employees. The object of providing good
ventilation alongside air conditioning in residential and commercial buildings is to
provide conditions under which people can live and work in comfort and safety.

Developed and refined over the past 30 years, the


Lossnay system has perfected the recovery
of waste energy. The units reduce overall
energy costs by extracting stale air and then
recovering the heating or cooling energy
to either warm or cool incoming fresh air.
By utilising this energy, the Lossnay system
can save up to 30% on initial capital costs of
heating and cooling plant.

Page 200
Effective
The Secret
of the Lossnay System
The secret of the Lossnay system lies in the cross flow,
plate fin structure of the heat exchange unit.
A diaphragm made of specially processed
paper fully separates inlet and exhaust
air supplies, ensuring that only fresh air is
introduced to the indoor environment.
The superior heat-transfer and moisture
permeability of the special paper ensures
highly efficient total heat exchange
(temperature and humidity) when inlet
and exhaust air supplies cross in the
Lossnay element.

Page 201
Main features of
Lossnay
Effective ventilation
Lossnay’s simultaneous air exhaust/supply provides effective ventilation.
Conventional ventilators (i.e. extract propeller fans) do not work effectively
within air tight buildings because of the negative air pressures involved.

Good energy recovery


Total heat (sensible and latent) recovery provides a comfortable air temperature
within the room. The energy saved by using Lossnay contributes towards
lowering the heating or cooling requirement within the building, therefore
reducing the energy requirement and running costs.

Free cooling function (LGH series)


When the outdoor temperature is lower than the indoor air conditioned
temperature in the summer, Lossnay provides fresh outdoor cool air to
reduce the indoor air temperature.

Good sound attenuation


As the Lossnay core is made of paper and the permeable holes are
small, the Lossnay core provides outstanding soundproofing properties
and is appropriate for sound proof rooms.

Part L2 Building Regulations


With the introduction of Part L2 (Part J in Scotland), new building design is
changing to become more airtight, as well as energy efficient. The need for fresh
air has remained the same however and thus poses new challenges for modern
design. Lossnay fully meets these challenges due to its basic principal and its
efficient heat recovery. See the Technical Information Section for CIBSE
recommended fresh air rates.

Enhanced Capital Allowance (ECA)


LGH-RX4 now qualifies for Enhanced Capital Allowances.

Page 202
Total heat recover y
concept
Operation Operation
in winter in summer
4.6°C 25.6°C
Stale warm air (exhaust) Stale cool air (exhaust)

15.4°C 22.4°C
Fresh warm air Fresh cool air
(indoor supply air) (indoor supply air)

0°C 20°C Heating 27°C 21°C Cooling


Fresh cool air Stale warm air unit Fresh hot air Stale cool air unit
(outdoor air) (indoor air) (outdoor air) (indoor air)

Using a Lossnay LGH-100RX4 in the winter example above, 8.9kW of heat is recovered per hour from the extracted air.

Page 203
Lossnay working in conjunction
with air conditioning
Lossnay units can work either on their own to provide fresh air into a room,
or in combination with Mr Slim or City Multi ceiling cassettes and ducted units.

When working together with air conditioning, Lossnay units can provide significant energy savings
by automatically utilising free cooling as well as heat recovery. As the Lossnay and the air conditioning
unit are connected by a two core communication cable, they can work together to optimise both
comfort and energy efficiency. This is done by the Lossnay reading the mode and set temperature
the air conditioning wants, then utilising the outside temperature to help achieve the required
temperature either by free cooling or heat recovery.

When using Lossnay in conjunction with air conditioning the heating and cooling loads can be
reduced significantly, reducing the running costs by up to 30% compared with air conditioning
systems without heat recovery systems.

Above example: One LGH25RX4 serving one PLA-RP71BA.


Room size 7m x 7m, 140w/m2 heat load. 7 people per room,
10litres/per/person of fresh to meet Part F requirements.
Maximum amount of fresh air to be introduced is 30% of the
fan coil volume. Ceiling cassettes may require fresh air casements.
Free cooling is not available below 8ºC when interlocked with
Mr Slim or City Multi units.

Lossnay fan speed


button is incorporated
within the standard PAR-21MAA
and PAR-F27MEA controllers

The graph opposite shows the hourly temperature for 2006 in London between 8.00am - 6.00p.m.
The point to note is the amount of free cooling available during these hours, as well as the heat
recovery below (22% of the time) and cooling recovery above (20% of the time). Lossnay is a year
round solution for providing fresh air.

Page 204
Free cooling provided by Lossnay was
available in London over 58% of
the time in 2006

Ambient Temperature - London 2006, 8am - 6pm

Over 58% of the time between


8am-6pm, the temperature in London
was between 8ºC and 20ºC, allowing
free cooling when the air conditioning
setpoint was 21ºC in cooling mode.
If the setpoint is higher, free cooling
is increased.

Page 205
Hyper Lossnay Core
LGH-RX4 Lossnay units feature the newly developed “Hyper Lossnay Core”, which uses non-porous, ultra-thin film to
achieve high enthalpy exchange efficiency. With a thickness of only 25µm, these are the thinnest in the world and are
approximately one fifth the thickness of previous Mitsubishi Electric products. Moisture permeability is dramatically
increased and enthalpy heat exchange greatly improved.

Comparison of new and old Lossnay Core cross-sections


Previous Lossnay Core New Hyper Lossnay Core Comparison of material
used in Hyper Lossnay Core
(25µm ultra-thin film)
with regular paper
The thinnest paper used in regular
120µm 25µm printing is 51µm thick (used in
dictionaries) and the material of the
Porous partition plate Non-porous film partition plate Hyper Lossnay Core is approximately
half the thickness of this.

Use Thickness
Hyper Lossnay Core material 25µm
Previous Mitsubishi Electric material 120µm
Photocopier paper 100µm
Dictionary paper 51µm

Consists of a two-layer construction Consists of a specially processed


using a specially processed material structure based on a single-layer,
made of a preferential permeable non-porous, ultra-thin film material.
film on a porous base material. Moisture exchange (water vapour
This provides moisture permeability transmission) is promoted by the
and air barrier properties, but the special film, which increases the
two-layer construction makes a affinity for moisture (the thinner
certain thickness unavoidable. the film, the higher the permeability).
The non-porous ultra-thin film
material acts as a barrier
against air leakage.

Connect ducts in two different Standard installation


Installation with duct
direction changed

directions (Outdoor vents) A space is


necessary to
Can be
installed close
prevent the to the surface
Ducts can be connected in two different directions to the outdoor influx of of the wall.
vents thanks to collars and aperture plates that can be interchangeably rainwater.

placed in two different positions. This flexibility allows for installations


close to the surface of a wall and helps avoid cases where the stale
air exhaust vent would be blocked by an obstruction of some kind. Changing the duct direction

This makes both the planning and installation of Lossnay units that
much simpler.

Collar Aper ture Plate Exchangeable

Interface simply
Because an adaptor now comes as standard equipment, networking LGH RX4 systems connected with Mitsubishi Electric’s
line of air conditioners has never been easier. There is no need to purchase any extra parts, creating the possibility of very
simple systems and keeping initial costs as well as construction time and trouble to an affordable minimum.

Page 206
Multi-Ventilation Mode
Enables the appropriate supply/exhaust balance to be selected to suit
usage, environment and location.

All LGH models feature the "Multi-ventilation Ventilation Mode Supply Exhaust
Mode," which allows the air supply/exhaust Airflow Airflow

balance to be varied dynamically to suit the Power air supply/exhaust mode High High
usage environment and location. Modes can Power air supply mode High Low
be selected easily by setting the connectors Power air exhaust mode Low High
on the circuit board. Energy-saving ventilation mode Low Low

* "High" can be further set to "Extra high" using the dip switch.

Normal Office Small Office or Building Smoking Areas

Providing efficient ventilation while Using Lossnay compensates for using


Priority on air exhaust...
maintaining air supply/exhaust balance... extractor fans...

Power air supply


& air exhaust Power air supply Power air exhaust

Most widely-used pattern forming In smaller offices or buildings, there In locations such as smoking areas,
the basis for traditional ventilation may be insufficient air supply to the dirty air must be exhausted swiftly.
design. This allows the most efficient main rooms or offices due to the Setting the Power air exhaust mode
ventilation while maintaining the air excessive exhaust via extractor fans with the air supply switch on "Low"
supply/exhaust balance. The optimum located in toilets or kitchen areas. and the air exhaust switch on "High"
ventilation rate can be maintained by Setting to Power air supply mode (or "Extra high") on the main unit
selecting the Power air supply/exhaust with the air supply switch on allows efficient extraction of cigarette
mode with both the air supply "High" (or "Extra high") and the smoke and odours. Maintaining the
& air exhaust switched to "High" air exhaust switch on "Low" on area at a negative air pressure also
(or "Extra high") on the main unit. the main unit, allows efficient prevents dirty air from spreading
For example in an office, the control ventilation while making up to surrounding areas.
switches can be set to "High" to run for the insufficient air supply.
in Power air supply/exhaust mode
when a large number of people are
in the office, then switched to "Low"
to run in Energy-saving ventilation
mode late at night or on holidays
when there are few people present.

Page 207
Enhanced Capital Allowance
& Part L2
The need for energy efficiency is paramount and is determined by legislation and regulation.
To encourage efficient use of energy, the UK Government introduced the Enhanced Capital
Allowance Scheme (ECA). The number of qualifying products on the Energy Technology
Product List has recently been expanded and includes ‘air to air energy recovery’.
The Lossnay heat recovery units (LGH-RX4) have been designed to ensure
businesses qualify for ECA and benefit from the utmost efficiency, both
financially and environmentally.

How Enhanced Capital Allowances Work


Enhanced Capital Allowances are used to encourage businesses to invest in particular types
of equipment by providing up-front tax relief, as 100% of the allowances can be reclaimed
in the first year. So, using the below example of a £1000 investment in equipment that
qualifies for ECA’s, the company could reclaim £300 in the first year.

Enhanced Capital Allowance


Tax Rate 30%
% of expenditure to which allowance applies 100%
Equipment plus installation costs £1000
Taxable amount reduced by 100% OF £1000 = £1000
FIRST YEAR SAVING 30% of £1000 = £300

Part L2
Part L2 of the Building Regulations is undergoing a major change. With building
regulations tightened up from April 2006, new commercial buildings have to be
pressure tested to show they are airtight and energy efficient. Proof will
also be needed to show that the new buildings will not overheat
and the occupants will be able to work comfor tably.
This means that the fresh air requirements are even more
important than ever before. Lossnay offers many features
that will help the building designer as well as the occupants
and with Lossnay’s high efficiency, unique controllability and
its modular design approach, Lossnay will assist greatly in
Part L2 compliance.

Page 208
Enhanced Capital
Allowance Scheme (ECA)

The key features of the ECA scheme:


I Under the scheme, all businesses liable for UK corporation tax, are able to claim an enhanced capital allowance on any
qualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector)
I Businesses can offset the full cost of specific technologies (such as Lossnay)
against taxable profits of the period of the investment
I In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the Energy
Technology Criteria List. Our LGH-RX4 Lossnay systems fully meet this criteria in their drive for energy efficiency
I Only investment in new and unused plant and machinery qualify

For further instructions go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the air to air energy recovery category.

Page 209
Restaurants Schools
A restaurant can never be too Creating the best
clean and its air never too fresh possible environment
The atmosphere of a restaurant is crucial for our children to succeed
to securing and retaining customers. Cleanliness Children deserve all the help we can give them
is the key to an attractive atmosphere and to grow up healthy, happy and prosperous. No
restaurants devote significant effort to ensuring matter how good a school's curriculum, no matter
their premises are sanitary. Sanitation and cleanliness, how positive and enthusiastic the teacher, a child who
however, are not enough. No matter how clean does not feel well will have a hard time learning.
a restaurant may look, if there are bothersome A constant flow of fresh air is nowhere as
odours lingering in the air, all those efforts go important as it is in our schools. In classrooms
to waste and the restaurant's clean image is where large numbers of students are gathered
tarnished. For these reasons, Lossnay’s superior for long periods of time, carbonic gases have
ventilation capabilities ensure that every breath is the tendency to accumulate, decreasing the levels
a fresh one and a pleasant environment is of oxygen that are vital for alertness and
maintained for guests at all times. Lossnay also concentration. This is especially true during the
keeps owners happy with its remarkable heat winter months when windows tend to remain
recovery technology that supplies fresh outdoor closed. Lossnay ventilates fresh outdoor air into
air with minimal change to indoor temperature, classrooms to replenish the supply of oxygen
saving on energy costs. and expels not only carbon dioxide, but also other
pollutants and odours that inevitably sully the air.

If it’s Lossnay If it’s Lossnay

Lossnay works to remove stale air and supply The continuous influx of fresh, outdoor air and
fresh, clean air free of the odours associated the exhaust of stale, indoor air ensure that the
with cooking, cigarettes and the people indoor oxygen level is maintained at just the
working and dining. right balance for comfort and health.

Change in room temperature is kept to a Occupants have the luxury of breathing fresh
minimum during ventilation thanks to the air at all times even in highly air-tight buildings.
heat-recovery function.
Lossnay's sound attenuation qualities prevent
The Lossnay operate very quietly, so those in outside noise from penetrating into the room,
the midst of enjoying their meals will not be helping to maintain a quiet environment for
bothered by any excess noise. productive study.

A large array of Lossnay sizes are available to Heat-exchange technology prevents fluctuations
match the layout of just about any restaurant. in temperature creating significant energy
savings when either heating or cooling a room.

What would you most like to see improved in restaurants? O2 Concentration and Deficiency
21 %
52.3% 21 18 %
Others: no response
Improvement Promotion of waste prevention: 5.4%
16 %
in overall 15
O2 Concentration (%)

Improvement in atmosphere: 6.5%


cleanliness Reduction of time required for 12 %
food to reach the table: 12.0% 10 %
Increased respiration

strength (precursors

10 8%
Dizziness, nausea,

Unconsciousness
Safety minimum

Improvement in
Paleness of skin,

(death in 8 min)

6%
loss of muscle

employees attitude towards


Normal air

customers: 20.5%
Comatosis

Convulsions,

5
stops, death
and pulse

of death)

vomiting,

respiration

1996 Foodstuffs Consumption Monitor, Second Periodic Survey


( Ministry of Agriculture, Forestry and Fisheries, Japan) 0

Page 210
Lossnay Selection / Payback Software
and Quick Reference Guide available
to order from your local sales office

Offices If it’s Lossnay


Fresh air - improving the overall
quality of working life
Simultaneous forced-air supply and exhaust
Many office buildings today are heavily insulated, air-tight introduces fresh, outdoor air into the building,
structures with little or no natural ventilation. The unnatural effectively ventilating even fully airtight structures.
environment created by air conditioners without added
ventilation is a breeding ground for bacteria. Factor this in Multiple split-type units operate independently
with the accumulation of pollutants and odours in the form of of one another, simplifying system set up and
ensuring a layout that optimally matches
cigarette smoke, formaldehyde, pollen, dust, carbon dioxide nearly any office design.
and the necessity of ventilation becomes ever more apparent.
In fact, poorly ventilated buildings can give rise to Sick Building Lossnay operation can be interlocked with
Syndrome, a malady that is known to cause headaches, sore air-conditioning system operation.
eyes, itching and loss of concentration. This results not only
in discomfort at best and sickness at worst for the building's Heat that is commonly lost due to ventilation
occupants, but also the reduced productivity of the workforce. is collected and reused thanks to the
Lossnay Core, reducing an air conditioners
Fresh air, effectively ventilated throughout the building is
energy load and cutting operating costs.
therefore essential to the overall quality of working life.

Page 211
The unbeatable
Lossnay
The Lossnay allows the extraction of stale

air and efficient recover y of heating

or cooling energy to treat

incoming fresh air. Whatever

your environment, it’s simple to improve

it with Lossnay.

Simple technology
at its best
Systems marked with the ECA logo are registered on the Energy Technology List and
hence qualify for 100% first year enhanced capital allowances (whole system cost and
‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 212
Contents
214 Total Heat Exchangers Residential Model

216 LGH-RX4 Commercial Series

180

182

Page 213
Total Heat Exchangers
Residential Model
Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation,
which require ventilation to remove stale air without major heat loss.

I Effective fresh air ventilation

I Efficient recovery of heating/cooling energy

I Good sound attenuation

I Reduces heating costs

Technical Information
LOSSNAY
MODEL REFERENCE RESIDENTIAL WALL- MOUNTED VL 100U

ELECTRICAL POWER SUPPLY 220 - 240V, 50Hz

PHASE Single

POWER CONSUMPTION (W) Low 23


High 26

AIRFLOW (m3/h) Low 65


High 105

NOISE (dBA) Low 29.5


High 39

TEMPERATURE Low 77
EXCHANGE
EFFICIENCY (%) High 70

WEIGHT (kg) 6.5

DIMENSIONS (mm) Width 620


Depth 168
Height 265

DUCT SIZE (mm) 2xØ75

FUSE RATING (BS88) - HRC (A) 6

MAINS CABLE No. Cores 3

Page 214
VL 100U
Dimensions

Page 215
Total Heat Exchangers Residential Model Lossnay Range 2008
LGH-RX4
Commercial Series
This commercially orientated system can be utilised virtually anywhere.

I Effective fresh air ventilation


I High heat recovery
I Free cooling function
I Good sound attenuation
I New “Hyper Lossnay Core”. At only 25µm (approx 1/5 the
thickness of LGH-RX3) the Lossnay core uses the thinnest paper
in the world to achieve high enthalpy exchange efficiency

Stale exhaust air


Heat exchange unit
(Lossnay core)
Fresh air from outside

Stale room air extracted

Fresh air supply to the room

Technical Information
LOSSNAY
MODEL REFERENCE COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL
LGH-15RX4 LGH-25RX4 LGH-35RX4 LGH-50RX4 LGH-80RX4 LGH-100RX4 LGH-150RX4 LGH-200RX4
ELECTRICAL POWER SUPPLY 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz
STARTING CURRENT (A) 0.7 0.8 1.7 1.9 3.6 5.4 7.2 10.8
RUNNING CURRENT (A) Low 0.22 0.25 0.48 0.60 1.40 1.70 2.70 3.50
High 0.31 0.40 0.71 0.90 1.60 2.00 3.10 4.20
Extra High 0.45 0.49 0.79 0.95 1.70 2.10 3.30 4.30
INPUT POWER (W) Low 51 59 110 142 315 400 625 820
High 73 96 167 214 370 475 730 980
Extra High 107 117 187 225 385 490 770 1010
AIRFLOW (m3/h) Low 110 165 230 350 670 870 1250 1650
High / Extra High 150 250 350 500 800 1000 1500 2000
AIRFLOW (l/s) Low 31 46 64 97 186 242 347 458
High / Extra High 42 69 97 139 222 278 417 556
EXTERNAL STATIC Low 35 25 25 30 70 80 70 65
PRESSURE (PA) High 60 50 70 60 100 100 100 90
Extra High 95 80 150 150 140 160 140 150
NOISE (dBA) Lossnay Low 23 23 24 24.5 31 32.5 33.5 36
High 25 26 30 31.5 33 35 36.5 38
Extra High 27 27.5 32 34 34.5 37 37.5 40
Bypass Low 23 23 24 25.5 31.5 34 36.5 37
High 25 26.5 30 33 34 36.5 38.5 39.5
Extra High 27 28 32.5 35.5 35.5 38 40 41
TEMPERATURE Low 81 83.5 84 82 80.5 81 81.5 81.5
EXCHANGE High 77 78 79 77 78 79 79 79
EFFICIENCY (%) Extra High 77 78 79 77 78 79 79 79
ENTHALPY Heating Low 74 77 77 73.5 73.5 74 74.5 75
EXCHANGE High / Extra High 70 70 70 67.5 71 71 72 71
EFFICIENCY (%) Cooling Low 70 71 74.5 71.5 70.5 69.5 72 71
High / Extra High 64.5 65 68 64.5 67 67 68 67
WEIGHT (kg) 17 21 30 33 61 69 124 140
DIMENSIONS (mm) Width 610 735 874 1016 1004 1231 1004 1231
Depth 780 780 888 888 1164 1164 1164 1164
Height 275 275 317 317 398 398 800 800
DUCT SIZE (mm) 100 150 150 200 250 250 (SA,RA)250 (OA,EA)270x700 (SA,RA)250 (OA,EA)270x700
*1
STANDARD FILTER EU3 EU3 EU3 EU3 EU3 EU3 EU3 EU3
FUSE RATING (BS88) – HRC (A) 6 6 6 6 6 10 16 16
MAINS CABLE NO. CORES 3 3 3 3 3 3 3 3

Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High mode available via dip switch setting.
Noise measured at 1.5m under the centre of panel.
*1: Eu7 filter available as optional parts.

Page 216
Lossnay Range 2008
Dimensions

LGH-15RX4 to LGH-200RX4

M-NET Controller Lossnay Controller


PZ-52SF-E (M-NET) PZ-41SLB-E
Control 16 Lossnay units from sizes Control 15 Lossnay units from sizes
15 -100 or up to 8, sizes 150 - 200 15 -100 or up to 7, sizes 150 - 200
120

120
70 8 33 70 8 33

48 48

LGH-15-100RX4 > LGH-150-200RX4 >

LGH RX4 Commercial Series

MODEL REFERENCE DIMENSIONS CEILING SUSPENSION FIXTURE PITCH NOMINAL


A B C D E DIAMETER

LGH-15RX4 780 610 275 700 641 ø100


LGH-25RX4 780 735 275 700 765 ø150
LGH-35RX4 888 874 317 790 906 ø150
LGH-50RX4 888 1016 317 790 1048 ø200
LGH-80RX4 1164 1004 398 1030 1036 ø250
LGH-100RX4 1164 1231 398 1030 1263 ø250

MODEL REFERENCE A B C

LGH-150RX4 1004 690 1046


LGH-200RX4 1231 920 1273

Page 217
Controls
A comprehensive range of control options
The importance of
The need for control is paramount A degree of
in order to optimise the performance
of any air conditioning system difference
and minimise its running costs.
Mitsubishi Electric offer a wide When an air conditioning system is not properly
range of control options designed controlled, it will not run as efficiently as it should.
For every degree that the system deviates from
to do just this.
the required temperature, energy costs can rise
by up to 5%. Specify one of the many control
Operating an air conditioning system without
options from Mitsubishi Electric to ensure
the right control can prove costly. It’s therefore
air conditioning works as intended, whilst giving
important to ensure that every system is
the optimum amount of control.
correctly specified to the degree of control it
requires. Mitsubishi Electric have a wide range
of controls available ‘off-the-shelf ’ and where
needed, individual control systems can be The simpler
specifically designed to suit.
the better
Good controls will benefit any application, large
or small. Air conditioning products need to With the array of comprehensive control
react to a variety of factors: different room systems available from Mitsubishi Electric,
sizes, usage and staff levels; changes in the it becomes simple to design and install air
climate; electronic equipment and lighting ... the conditioning systems. From a simple hand held
list goes on. So whatever the application, controller to a G50 system - you are in control.
optimum control of air conditioning systems
is essential and will result in a constant,
comfortable environment, which in turn is both
energy and cost efficient.

Page 220
Control
Controlled In accordance with the requirements of part L2 in the Building Regulations, our control systems
provide the optimum control available, combined with the most efficient use of energy.

performance
A wide range of
Controls options
The need for control is paramount in order

to optimise the performance of any air conditioning

system and minimise its running costs.

Mitsubishi Electric offer a wide range of

control options designed to do just this.

Simple technology
at its best

Page 222
Contents
224 Remote Controllers
225 Programmable Timer
226 System Controller
227 Interfaces
228 G50 Controller, Centralised Controller
229 AG150 Controller, Centralised Controller
230 GB50 Controller, Centralised Controller
231 G50/GB50/AG150 Controller, Web Screenshots
232 G50/GB50/AG150 Desktop Remote Controller
233 G50/GB50/AG150 Third Party Equipment Interfaces
234 G50/GB50/AG150 Programmable Logic Controller (PLC)
235 TG2000 Software, PC Based Software Package
236 TG2000 Software with Energy Monitoring
237 TG2000 Software with Third Party Equipment
238 TG2000 WAN Software (Wide Area Network)
239 TG2000, Screenshots
240 BEMS BACnet® Interface (BAC-IP/50)
241 BEMS BACnet® Mr Slim Interface (BAC-A/50)
242 BEMS LonWorks® Interface (LMAP)
243 BEMS Modbus Interfaces (IP-32/50/100M)
244 BEMS Modbus Mr Slim Interface (A32M)
245 BEMS Modbus Splits Interface (A1M)
246 BEMS KNX-EIB Interfaces (KNX-EIB-IP-15/100)
247 BEMS KNX-EIB Splits Interface (KNX-EIB-A-1)
248 M2M - Machine 2 Machine Interface (Maxi M2M-IP/50)
249 M2M - Machine 2 Machine Splits Interface (Mini M2M-A/16)
250 M2M - Machine 2 Machine Web Screenshots
251 G50 Control Panels
252 Run / Standby Control Panels
253 Energy Monitoring Control Panels
254 Split-System A2M Interfaces

Page 223
Remote Controllers
Our air conditioning systems are supported by a multitude of remote controllers. Each remote controller type,
whilst being able to support the general control and monitoring functions for a group of indoor units, can also offer
other unique operational features.

PAC-YT51CRA PAC-SE51CRA BS-51COV PC-51COV PB-51COV PAR-21MAA PAR-F27MEA PAR-FL32MA

Technical Information

Remote Controllers
FUNCTION DESCRIPTION PAC-YT51CRA PAC-SE51CRA PAR-21MAA PAR-F27MEA PAR-FL32MA
Operation Display Operation Display Operation Display Operation Display Operation Display

ON/OFF Run and Stop operation for a single group          

MODE SELECTION Switches between Cool/Dry/Auto/Fan/Heat.


Operation mode will vary depending on the
       
indoor unit. Auto mode is available with only
R2 and WR2 systems

TEMPERATURE Sets the groups temperature control.


SETTING Cool/Dry: 19-30°C          
Heat: 17-28°C
Auto: 19-28°C

FAN SPEED SETTING 4 speed - Lo-Mi1-Mi2-Hi


         
2 speed - Lo-Hi

SETPOINT LIMIT Limit the setpoint range     

AIRFLOW DIRECTION Air Flow angles:100º-80º-60º-40º      


and auto swing

INDEPENDENT VANE Only available with PLA-RP-BA, PLFY-P-VBM-E


 
CONTROL and PLFY-P-VCM-E

TIMER OPERATION ON/OFF time can be set. Weekly Weekly Daily Daily Daily Daily

PERMIT / PROHIBIT Run/Stop, Temperature Setting, Mode Selection


and Filter Reset functions can be prohibited     
FUNCTION via a higher level system controller

INDOOR RETURN Measures the intake temperature of


the master unit within the group  
AIR TEMPERATURE
ERROR INDICATION Displays a 4 digit code and the affected unit address    

TEST RUN FUNCTION Allows each unit within the group        


to operate in test mode

VENTILATION Allows the group to be interlocked


with a heat recovery Lossnay unit    
INTERLOCK
OPTIONAL COVER Brushed Stainless Steel  
Polished Chrome  
Polished Brass  

CONTACT NUMBER Displays under fault condition, the fault code


UNDER FAULT of the unit with its address and the contact 
CONDITIONS number to call

MULTIPLE LANGUAGES English, Italian, Spanish, French, German,


Russian, Chinese and Japanese  

CLOCK DISPLAY Displays time 

BUTTON LOCK Able to lock all controller buttons, or


all controller buttons except On/Off    

EASY MAINTENANCE Able to monitor information about the


compressor (running current, running time,
WITH MR SLIM On/Off time). Also able to monitor sensors:  
h-exh, outdoor outlet, outdoor temp, indoor inlet,
indoor h-exh and filter use number of hours

RUN / STANDBY WITH Able to switch over two systems every week.
If one fails, the other system starts. If the  
MR SLIM temperature is too high, the two systems start.

Compatible with: Mr Slim or Mr Slim or City Multi,


COMPATIBILITY City Multi City Multi Mr Slim or
M Series (via MAC-397IF) M Series (via MAC-397IF) M Series (via MAC-397IF)
DIMENSIONS - mm 120x41x70 130x19x120 130x19x120
120x41x70 157x18x57
(WxDxH)

Page 224
Controls Range 2008
Programmable Timer
Mitsubishi Electric controllers are complimented by a weekly programmable timer, being able
to control up to fifty indoor units. The PAC-YT34STA also has hardwired connection
available (On/Off input, fire alarm input, run output, fault output).

PAC-YT34STA PAC-YT34STA PAC-SC50KUA

Technical Information

Programmable Timer
FUNCTION DESCRIPTION PAC-YT34STA
UNITS Max No. of Indoor Units 50 units/50 groups 50 units/50 groups
 

Remote Controllers / Programmable Timer


Operation Display

ON/OFF Run and Stop operation  

MODE SELECTION Switches between Cool / Heat  

TEMPERATURE SETTING Sets the groups temperature control.


Cool/Dry: 19-30°C  
Heat: 17-28°C
Auto: 19-28°C

CURRENT TIME Set the time  

ERROR INDICATION Displays a 4 digit code and the affected



unit address

EXTERNAL INPUT Hardwired connections available On/Off or Fire Alarm

EXTERNAL OUTPUT Hardwired connections available Run/Faults

COMPATIBILITY Compatible with: City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF

DIMENSIONS - mm
130x19x120
(WxDxH)

NOTE: Units can only be controlled from the scheduling options. When the remote On/Off hardwired input is used, the On/Off remote controller buttons will be deactivated (centrally controlled).

Page 225
System Controller
One system controller is available for use when you need to control up to fifty indoor units from one location.
The PAC-SF44SRA also has hardwired connection available (On/Off input, fire alarm input, run output, fault output).

PAC-SF44SRA PAC-SF44SRA PAC-SC50KUA

Technical Information

System Controller
FUNCTION DESCRIPTION PAC-SF44SRA
UNITS Max No. of Indoor Units 50 units/50 groups 50 units/50 groups
  Operation Display 

ON/OFF Run and Stop operation  

MODE SELECTION Switches between Cool/Dry/Auto/Fan/Heat.


Operation Mode will vary depending on the
 
indoor unit. Auto mode is available with
only R2 and WR2 systems

TEMPERATURE Sets the groups temperature control.


SETTING Cool/Dry: 19-30°C  
Heat: 17-28°C
Auto: 19-28°C

FAN SPEED SETTINGS 4 speed - Lo-Mi1-Mi2-Hi  


2 speed - Lo-Hi

AIR FLOW DIRECTION Air Flow angles: 100º-80º-60º-40º and auto swing  

PERMIT/PROHIBIT Run/Stop, Temperature Setting, Mode Selection


FUNCTION and Filter Reset functions can be prohibited  

INDOOR RETURN Measures the intake temperature of the 


AIR TEMPERATURE master unit within the group

ERROR INDICATION Displays a 4 digit code and the affected 


unit address

VENTILATION Allows the group to be interlocked  


INTERLOCK with a heat recovery Lossnay unit

EXTERNAL INPUT Hardwired connections available On/Off or Fire Alarm

EXTERNAL OUTPUT Hardwired connections available Run/Faults

COMPATIBILITY Compatible with: City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF

DIMENSIONS - mm
130x19x120
(WxDxH)

NOTE: When the remote On/Off hardwired input is used, the On/Off remote controller buttons will be deactivated (centrally controlled).

Page 226
Controls Range 2008
Interfaces
A range of newly created interfaces are now available for use when connecting to third party controllers.

TCB1 DIDO

TCB1 DIDO

Technical Information

Interfaces
FUNCTION DESCRIPTION TCB1 DIDO MS-FRT-TCB-TEMP
Control Monitor Control Monitor Control Monitor

ON/OFF BUT ON/OFF control. Remote controller


CENTRALLY ON/OFF button deactivated    
CONTROLLED

ON/OFF BUT ON/OFF control. Remote controller


NOT CENTRALLY ON/OFF button activated      
CONTROLLED

TEMPERATURE Sets the groups temperature control. 


System Controller / Interfaces

SETTINGS Cool/Dry: 19-30°C


Heat: 17-28°C
(analogue 0 to 10VDC)
Auto: 19-28°C

ERROR INDICATION  

HEATING A supplied remote sensor is installed


INTERLOCKING on the wet system radiator to
prevent the air conditioning
running while heating

COMPATIBILITY Interface compatible with: Mr Slim Mr Slim


Mr Slim
City Multi City Multi

DIMENSIONS - mm 80x45x80 130x19x120 130x19x120


(WxDxH)

Page 227
G50 Controller
Centralised Controller with WebServer Capabilities
The G50 centralised controller was the first of its kind in the industry to utilise Ethernet Technology. By using Internet
Explorer as its local or remote software, the G50 gives you instant access to all your control functions from the comfort of
your own PC. The G50 can control up to 50 indoor units and can take the place of local remote controllers, offering
the same level of monitoring and control. The G50 has many functions as standard but can also have further features
activated via Pin Codes.

M-NET

G50

ETHERNET PAC-SC50KUA

Viewed using Microsoft® Internet Explorer

Technical Information
G50 Controller
FUNCTION DESCRIPTION
OPERATION PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000
service pack 4 or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF INDOOR UNITS Up to 50 indoor units can be connected
ON/OFF Run and Stop operation for a single group
MODE SELECTION Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.
Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
FAN SPEED SETTING 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
AIR FLOW DIRECTION Air Flow angles:100º-80º-60º-40º and auto swing
TIMER OPERATION Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated

PERMIT/PROHIBIT FUNCTION Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection
and Filter Reset) can be activated
INDOOR RETURN AIR TEMPERATURE Displays the measured intake temperature from each group
ERROR INDICATION Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms
TEST RUN FUNCTION Allows each unit within the group to operate in test mode
VENTILATION INTERLOCK Allows the group to be interlocked with a heat recovery Lossnay unit
WEB SETPOINT LIMIT Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)
WEB AUTO CHANGEOVER Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements
WEB INITIAL SETTING Commission the G50 from the web pages
WEB LOGIN Administrator able to allow specific function access to guest
EXTERNAL INPUT/OUTPUT Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop
Outputs: Start/Stop Status, Error/Normal Status
POWER SUPPLY PACK PAC-SC50KUA
COMPATIBILITY City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF
DIMENSIONS - mm (WxDxH) 300x79x120

G50 Software Options - Pin Code Activation


G50 - Web Monitor Control and Monitor the G50 via Internet Explorer G50 - ES Energy Saving Capability
G50 - Email Enable E-mail activation on fault conditions G50 - PC Peak Cut Control
G50 - AS Weekly / Annual Scheduling and Night Set Back G50 - VRC Virtual Remote Controllers
G50 - EC Energy Charge

Page 228
Controls Range 2008
AG150 Controller NEW in September 2008

Touch Screen Centralised Controller with WebServer Capabilities


The new AG150 Mitsubishi Electric centralised controller offers a large 9 inch touch screen display with easy control
of up to 50 indoor units. The AG150 can calculate the energy used for each system, zone or indoor unit. The
refrigerant status check function can be activated regularly (in conjuction with the new YHM-A City Multi range)
and an Internet connection with SSL security is also available to monitor and control the AG150 remotely and
receive Email under fault conditions.

M-NET

AG150
ETHERNET PAC-SC51KUA

Viewed using Microsoft® Internet Explorer


Technical Information
AG150 Controller
FUNCTION DESCRIPTION

TOUCH SCREEN Wide high resolution 9” touch screen


OPERATION PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running
Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF INDOOR UNITS Up to 50 indoor units can be connected
ON/OFF Run and Stop operation for a single group
MODE SELECTION Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.
Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
FAN SPEED SETTING 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
AIR FLOW DIRECTION Air Flow angles:100º-80º-60º-40º and auto swing
TIMER OPERATION Annual or weekly. Night set back option available allowing the setpoint to be set to 12ºC
PERMIT/PROHIBIT FUNCTION Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting,
Mode Selection and Filter Reset) can be activated
INDOOR RETURN AIR TEMPERATURE Displays the measured intake temperature from each group
ERROR INDICATION Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms
TEST RUN FUNCTION Allows each unit within the group to operate in test mode
VENTILATION INTERLOCK Allows the group to be interlocked with a heat recovery Lossnay unit
G50 Controller / AG150 Controller
WEB SETPOINT LIMIT Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)
WEB AUTO CHANGEOVER Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements
WEB INITIAL SETTING Commission the G50 from the web pages
WEB LOGIN Administrator able to allow specific function access to guest
WEB REFRIGERANT STATUS CHECK Activate refrigerant volume checking function on Modular City Multi systems
ENERGY CHARGING Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA
ENERGY SAVE CONTROL Individual indoor unit, group of indoor units or a complete system can be controlled.
There are various energy saving options available (Optional)
LOAD SHEDDING Activate energy saving mode when energy consumption is too high

EXTERNAL INPUT/OUTPUT Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop
Outputs: Start/Stop Status, Error/Normal Status
POWER SUPPLY PACK PAC-SC51KUA
COMPATIBILITY City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF
DIMENSIONS - mm (WxDxH) 300x62x175

AG150 Software Options - Pin Code Activation


AG150 - Basic Web monitoring, Email, Annual scheduling
AG150 - Energy Energy monitoring, energy saving, load shedding
AG150 - VRC Virtual remote controllers

Page 229
GB50 Controller
Centralised Controller with WebServer Capabilities
The GB50 has been developed to access all your control functions from the comfort of your own PC,
without the need for a controller keypad or LCD display and at a very competitive price.

M-NET

GB50

ETHERNET PAC-SC50KUA

Viewed using Microsoft® Internet Explorer

Technical Information

GB50 Controller
FUNCTION DESCRIPTION
OPERATION PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running
Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF INDOOR UNITS Up to 50 indoor units can be connected
ON/OFF Run and Stop operation for a single group
MODE SELECTION Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.
Auto mode is available with only R2 and WR2 systems

TEMPERATURE SETTING Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
FAN SPEED SETTING 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
AIR FLOW DIRECTION Air Flow angles:100º-80º-60º-40º and auto swing
TIMER OPERATION Annual or weekly. Night set back option available allowing the setpoint to be set down to 12ºC
PERMIT/PROHIBIT FUNCTION Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection
and Filter Reset) can be activated
INDOOR RETURN AIR TEMPERATURE Displays the measured intake temperature from each group
ERROR INDICATION Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms
TEST RUN FUNCTION Allows each unit within the group to operate in test mode
VENTILATION INTERLOCK Allows the group to be interlocked with a heat recovery Lossnay unit
WEB SETPOINT LIMIT Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)
WEB AUTO CHANGEOVER Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements
WEB INITIAL SETTING Commission the GB50 from the web pages
WEB LOGIN Administrator able to allow specific function access to guest
EXTERNAL INPUT/OUTPUT Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop
Outputs: Start/Stop Status, Error/Normal Status
POWER SUPPLY PACK PAC-SC50KUA
COMPATIBILITY City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF
DIMENSIONS - mm (WxDxH) 250x38x130

GB50 Software Options - Pin Code Activation


G50 - EC Energy Charge
G50 - ES Energy Saving Capability
G50 - PC Peak Cut Control
G50 - VRC Virtual Remote Controllers

Page 230
Controls Range 2008
G50/AG150/GB50 Controller Web Screenshots
Login Monitor Air Conditioning - Overview

Access to the web pages is secured using a customised The first screen allows you to monitor all the units connected to the
username and password. G50/AG150/GB50. Each icon displays On/Off, Faults and timer On/Off.

Monitor Air Conditioning - Block view Remote Controller Settings

Each area of the building can be displayed with information Click on any icons in the Monitor View page to access the
about On/Off, Setpoint, Mode and Temperature. remote controller. Lossnay units can also be controlled.
Buttons on the local controllers may be locked
(On/Off, Mode, Setpoint, Filter Reset).
Daily, Weekly and Annual Scheduling
(AS PIN code) Monitor Fault Codes

Scheduling may be set from the web pages. Faults with the unit address can be displayed under
A night set back operation is available (Heat, 12ºC). fault conditions. Email status can also be shown.
Optional on the G50, standard on the AG150/GB50.
G50/AG150/GB50 Web Screenshots
Multiple Users (VRC PIN code) Multiple Users (VRC PIN code)
GB50 Controller /

If the G50/AG150/GB50 is connected to an office LAN, the Installation costs will be reduced as no wall remote
staff will then be able to access the web pages. With VRC each controllers will need to be purchased and installed.
member of staff will have their own username and password.

New icons now available to suit model type installed

Page 231
G50/AG150/GB50
Desktop Remote Controller
More and more customers are using the G50/GB50 controller directly from their computers, so Mitsubishi Electric has
launched a new, even simpler alternative which presents the customer with what looks like a standard remote controller
interface - on their PC desktop. Called the PAR-21PC, the new application can also be minimised in the Desktop Toolbar,
just like other Windows applications, so that the customer can have immediate control with just one click of the mouse.

M-NET

*NOTE 1

ETHERNET PAC-SC50KUA

Technical Information

PAR-21PC Desktop Remote Controller


FUNCTION DESCRIPTION
OPERATION PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running
Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF INDOOR UNITS Up to 16 indoor units within a group
ON/OFF Run and Stop operation for a single group
MODE SELECTION Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending
on the indoor unit. Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
FAN SPEED SETTING 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
AIR FLOW DIRECTION Air Flow angles:100º-80º-60º-40º and auto swing
CLOCK DISPLAY Displays the time on the desktop controller
INDOOR RETURN AIR TEMPERATURE Displays the measured intake temperature from each group
ERROR INDICATION Displays a 4 digit code and the affected unit address.
TIMER OPERATION Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 232
Controls Range 2008
G50/AG150/GB50
Third Party Equipment Interfaces
The new third party equipment interfaces allow the user to monitor and control third party equipment
from the G50/GB50 web pages.

ETHERNET

*NOTE 1

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Technical Information
Third Party Interfaces
FUNCTION DESCRIPTION PAC-YG66DCA PAC-YG63MCA

MAX No. OF INPUTS - 2 x Digital 2 x Analogue


MAX No. OF OUTPUTS - 2 x Digital -
MAX No. OF EQUIPMENT - 2 -

POWER SUPPLY Power supply required 24VDC 24VDC

MONITOR From G50/GB50 web pages Run / Faults Temperature / Humidity


or TG2000

CONTROL From G50/GB50 web pages On/Off -


or TG2000

SIGNAL Signal required to monitor Volt free contact Temperature 4-20mA / 1-5V / 0-10V / Pt100
and control equipment Humidity 4-20mA / 1-5V / 0-10V

DIMENSIONS - mm (WxDxH) - 200x45x120 200x45x120

General Equipment Temperature / Humidity

G50/AG150/GB50 Third Party Equipment Interfaces


G50/AG150/GB50 Desktop Remote Controller /

Third party equipment can be monitored and controlled Temperature and humidity can be monitored.
from the web pages.

Trend Logging Temperature / Humidity Limit

Temperature and humidity can be recorded and displayed. Limit (high and low) can be set to trigger alarms via email.

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA


NOTE 2: Temperature Sensors and Humidity Sensors not supplied by MEUK

Page 233
G50/AG150/GB50
Programmable Logic Controller
The PLC controller allows a hotel (for example) to have more accurate control over its air conditioning. The PLC
works in conjunction with the key card system installed in each bedroom in many hotels. When the room is occupied,
the PLC will switch ON the unit and reset the air conditioning to predetermined settings (for instance AUTO, 21ºC).
When the room is unoccupied, the PLC will monitor the temperature in the room. If the temperature is too low or
too high, the PLC will restart the unit.

M-NET

*NOTE 1

ETHERNET PAC-SC50KUA

Ving Card Ving Card Ving Card

PLC

Technical Information

PLC-QSERIES-LSPD
FUNCTION DESCRIPTION
MAX No. OF INDOOR UNITS Up to 200 indoor units
ON/OFF Run and Stop operation for a single group
MODE SELECTION Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.
Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
PERMIT/PROHIBIT SETTING Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting,
Mode Selection and Filter Reset) can be activated
OCCUPIED ROOM SETTING ON, AUTO, 21ºC (Factory setting)

UNOCCUPIED ROOM SETTING

If the temperature is below 16ºC If the temperature is above 26ºC


the PLC restarts the unit to ON, the PLC restarts the unit to ON,
HEAT, 19ºC and stops the unit COOL, 21ºC and stops the unit
when the temperature has reached when the temperature has reached
18ºC (Factory setting) 24ºC (Factory setting)

COMPATIBILITY City Multi only


DIMENSIONS - mm (WxDxH) 198x44x98

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA


NOTE 2: It may take up to 3 minutes to switch ON the indoor unit (this time depends on how many indoor units are connected to the PLC).

Page 234
Controls Range 2008
TG2000 Software
PC Based Software Package
The TG2000 centralised PC based graphical software package allows the operator to control and
monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to
an air conditioning system via the G50/GB50 controller, allowing the operator the required functionality
to control and monitor the complete air conditioning system from a central location.

M-NET

*NOTE 1

ETHERNET PAC-SC50KUA

Technical Information

TG2000 PC Based software that works in conjunction with G50/GB50 Controller


FUNCTION DESCRIPTION
OPERATING PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running

G50/AG150/GB50 Programmable Logic Controller /


Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF INDOOR UNITS 2000 Indoor units, 50 indoor units per G50/AG150/GB50
OPERATIONAL SECTIONS The software package is split into two distinctive areas, System and Controls setting. System Setting: Password
protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,
monitoring and control functions as described below. The software allows individual indoor units to be allocated
to logical groups, represented within user definable graphics screens, allocated during the system configuration
ON/OFF Indicates the On/Off status of each group within the selected graphical screen or entire building
OPERATION MODE Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
SET TEMPERATURE Displays the set temperature for each group on the selected graphical screen.
Also able to limit the set point range in both heating and cooling mode
AIR SPEED Displays the current fan speed setting for each group on the selected graphical screen
REMOTE CONTROLLER Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing.
Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen
or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
ROOM TEMPERATURE MONITORING Displays the return air temperature of the master indoor unit within a group
TG2000 Software

SCHEDULED ON/OFF On/Off schedules can be set for each group, each graphical screen or the entire building

ENERGY SAVE CONTROL Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy
saving options available (Optional)

TREND LOGGING Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit,
watt-hour meter and then email to customer

GRAPHICAL SCREENS The complete system configurations can be allocated between multiple screens. Each screen can display a
bitmap image representing the area of the building or floor where the units or groups are physically located
EMAIL The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data,
trend logging data (temperatures etc) and fault code history

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 235
TG2000 Software with Energy Monitoring
PC Based Software Package
The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a
maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via
G50/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air
conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows
complete energy consumption data to be logged with user definable billing groups and electrical tariffs for billing purposes.

M-NET

*NOTE 1

ETHERNET
PAC-YG60MCA
PAC-SC50KUA

METER 1 METER 2 METER 3 METER 4

Technical Information
TG2000 Software with Energy Monitoring
FUNCTION DESCRIPTION
OPERATING PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows
Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF INDOOR UNITS 2000 Indoor units, 50 indoor units per G50/AG150/GB50
OPERATIONAL SECTIONS The software package is split into two distinctive areas, System and Controls setting. System Setting: Password
protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,
monitoring and control functions as described below. The software allows individual indoor units to be allocated
to logical groups, represented within user definable graphics screens, allocated during the system configuration
ON/OFF Indicates the On/Off status of each group within the selected graphical screen or entire building
OPERATION MODE Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
SET TEMPERATURE Displays the set temperature for each group on the selected graphical screen.
Also able to limit the set point range in both heating and cooling mode
AIR SPEED Displays the current fan speed setting for each group on the selected graphical screen
REMOTE CONTROLLER Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing.
Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen
or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
ROOM TEMPERATURE MONITORING Displays the return air temperature of the master indoor unit within a group
SCHEDULED ON/OFF On/Off schedules can be set for each group, each graphical screen or the entire building
ENERGY CHARGING Able to create or email bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA
WEB REFRIGERANT STATUS CHECK Activate refrigerant volume checking function on Modular City Multi systems
ENERGY CHARGING Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional)
via the PAC-YG60MCA
ENERGY SAVE CONTROL Individual indoor unit, group of indoor units or a complete system can be controlled.
There are various energy saving options available (Optional)
LOAD SHEDDING Activate energy saving mode when energy consumption is too high

TREND LOGGING Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit,
watt-hour meter and then email to customer
GRAPHICAL SCREENS The complete system configurations can be allocated between multiple screens. Each screen can display
a bitmap image representing the area of the building or floor where the units or groups are physically located
EMAIL The following information may be sent regularly and automatically via email: energy monitoring data,
energy saving data, trend logging data (temperatures etc) and fault code history

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA


NOTE 2: Energy Meters not supplied by MEUK

Page 236
Controls Range 2008
TG2000 Software
with Third Party Equipment
PC Based Software Package
The TG2000 centralised PC based graphical software package allows the operator to control and monitor up
to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning
system via G50/GB50 controller, allowing the operator all the required functionality to control and monitor the
complete air conditioning system from a central location. In addition to providing a centralised control facility,
the TG2000 allows you to monitor and control third party equipment.

M-NET

*NOTE 1

ETHERNET
PAC-SC50KUA

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Technical Information
TG2000 Software with Third Party Equipment
FUNCTION DESCRIPTION
OPERATING PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running
Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF INDOOR UNITS 2000 Indoor units, 50 indoor units per G50/AG150/GB50
OPERATIONAL SECTIONS The software package is split into two distinctive areas, System and Controls setting. System Setting: Password

TG2000 Software with Third Party Equipment


protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,
monitoring and control functions as described below. The software allows individual indoor units to be allocated

TG2000 Software with Energy Monitoring /


to logical groups, represented within user definable graphics screens, allocated during the system configuration
ON/OFF Indicates the On/Off status of each group within the selected graphical screen or entire building
OPERATION MODE Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
SET TEMPERATURE Displays the set temperature for each group on the selected graphical screen.
Also able to limit the set point range in both heating and cooling mode
AIR SPEED Displays the current fan speed setting for each group on the selected graphical screen
REMOTE CONTROLLER Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing.
Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen
or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
ROOM TEMPERATURE MONITORING Displays the return air temperature of the master indoor unit within a group

SCHEDULED ON/OFF On/Off schedules can be set for each group, each graphical screen or the entire building

ENERGY SAVE CONTROL Individual indoor unit, group of indoor units or a complete system can be controlled.
There are various energy saving options available (Optional)

TREND LOGGING Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit,
watt-hour meter and then email to customer
GRAPHICAL SCREENS The complete system configurations can be allocated between multiple screens. Each screen can display a
bitmap image representing the area of the building or floor where the units or groups are physically located
THIRD PARTY EQUIPMENT MONITOR Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA
THIRD PARTY EQUIPMENT CONTROL Control general equipment On/Off via the PAC-YG66DCA
EMAIL The following information may be sent regularly and automatically via email: energy monitoring data,
energy saving data, trend logging data (temperatures etc) and fault code history

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA


NOTE 2: Temperature and Humidity Sensors not supplied by MEUK

Page 237
TG2000 WAN (Wide Area Network) Software
PC Based Software Package used to monitor and control multiple sites
The TG2000 WAN centralised PC based graphical software package allows the operator to control and monitor up
to a maximum of 1000 sites. Utilising the companies Wide Area Network, the complete (geographically distributed)
air conditioning asset base can be controlled and monitored from a centralised location.

PAC-YG66DCA PAC-YG63MCA

WAN SITE 1
(i.e. MANCHESTER)
*NOTE 1

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

PAC-YG66DCA PAC-YG63MCA

SITE 999
(i.e. BIRMINGHAM)
*NOTE 1

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Technical Information
TG2000WAN (Wide Area Network) Software
FUNCTION DESCRIPTION
OPERATING PLATFORM Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional
2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista
MAX No. OF SITES 1000
MAX No. OF INDOOR UNITS PER SITE 2000 Indoor units, 50 indoor units per G50/AG150/GB50 (per site)
OPERATIONAL SECTIONS The software package is split into two distinctive areas, System and Controls setting. System Setting: Password
protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,
monitoring and control functions as described below. The software allows individual indoor units to be allocated
to logical groups, represented within user definable graphics screens, allocated during the system configuration

ON/OFF Indicates the On/Off status of each group within the selected graphical screen or entire building
OPERATION MODE Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
SET TEMPERATURE Displays the set temperature for each group on the selected graphical screen.
Also able to limit the set point range in both heating and cooling mode
AIR SPEED Displays the current fan speed setting for each group on the selected graphical screen
REMOTE CONTROLLER Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
PROHIBIT/PERMIT
ABNORMALITY (FAULT) MONITORING Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing.
Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or
the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

ROOM TEMPERATURE MONITORING Displays the return air temperature of the master indoor unit within a group

SCHEDULED ON/OFF On/Off schedules can be set for each group, each graphical screen or the entire building
GRAPHICAL SCREENS The complete system configurations can be allocated between multiple screens. Each screen can display a
bitmap image representing the area of the building or floor where the units or groups are physically located
THIRD PARTY EQUIPMENT MONITORING Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA

THIRD PARTY EQUIPMENT CONTROL Control general equipment On/Off via the PAC-YG66DCA
EMAIL The following information may be sent regularly and automatically via email: energy monitoring data,
energy saving data, trend logging data (temperatures etc) and fault code history

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA


NOTE 2: The TG2000 WAN cannot be utilised if the following site functions are required: energy charging, energy saving and trend logging.
NOTE 3: Temperature and Humidity Sensors not supplied by MEUK

Page 238
Controls Range 2008
TG2000 Screenshots
Display Whole Display Block

The 2000 indoor units status may be shown Block may be set for each area. Settings may be
on one screen. changed by one click of the mouse for each area.

Display Floor Remote Controller Settings

AutoCAD drawing may be imported to Click on any icons in the floor view to access the remote
TG2000 to display floor screens. controller settings. Buttons on the local controllers may
be locked (On/Off, Mode, Setpoint, Filter reset).

Daily, Weekly and Annual Scheduling (AS PIN code) Monitor Fault Codes

Scheduling may be set from the TG2000. A night set Faults with the unit address can be displayed under
back operation is available (HEAT, 12ºC). Optional fault conditions.
on the G50, standard with the GB50. TG2000 WAN / TG2000 Screenshots
Energy Monitoring (EC PIN code) Energy Saving (ES PIN code)

TG2000 in conjunction with energy meters can monitor TG2000 offers different energy saving options
the energy consumption for each outdoor unit, indoor unit including load shedding.
or area. The indoor unit run hours can also be displayed.

New icons now available to suit model type installed

Page 239
BEMS BACnet Interface
®

Procon BAC-IP/50 TM

To further enhance our complete open system network offering, we offer a BACnet gateway solution. Utilising
®

the ASHRAE BACnet standard, complete control and monitoring integration can be achieved with up to 50
®

air conditioning units.

M-NET

*NOTE 1

ETHERNET PAC-SC50KUA

BAC-IP/50

Technical Information

BACnet INTERFACE
®

FUNCTION BAC-IP/50 COMPATIBLE WITH


MAX No. OF
50 Andover Controls
INDOOR UNITS
York BMS
City Multi
COMPATIBILITY Mr Slim via PAC-SF80MA Siemens
M Series via MAC-399IF
Priva Building Intelligence
DIMENSIONS - mm
144x34x104 Delta Controls
(WxDxH)

BACnet INTERFACE
®

FUNCTION NETWORK VARIABLE NOTES


Control
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control Lo-Mi1-Mi2-Hi
Permit / Prohibit On/Off, Mode, Setpoint
Airflow Direction Horizontal - 60,80,100º swing
Filter Sign Normal/Reset

Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control Lo-Mi1-Mi2-Hi
Permit / Prohibit On/Off, Mode, Setpoint
Airflow Direction Horizontal - 60,80,100º swing
Fault Code 4 Character code - Indicates all unit alarms
Filter Sign -
Room Temperature -

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 240
Controls Range 2008
BEMS BACnet Mr Slim Interface
®

Procon BAC-A/50 TM

®
A new BACnet Interface has been specially developed for the Mr Slim systems. The BAC-A/50 can
control up to 50 individual systems.

PAC-SK81SI

BAC-A/50

Technical Information

BACnet MR SLIM INTERFACE


®

FUNCTION BAC-A/50 COMPATIBLE WITH


MAX No. OF
50 Andover Controls
OUTDOOR UNITS
York BMS
COMPATIBILITY Mr Slim via PAC-SK81SI Siemens
Priva Building Intelligence
DIMENSIONS - mm
270x75x210 Delta Controls
(WxDxH)

BACnet MR SLIM INTERFACE


®
BEMS BACnet® Mr Slim Interface
FUNCTION NETWORK VARIABLE NOTES
Control
On/Off Run/Stop
BEMS BACnet® Interface /

Mode Operation Cool / Dry / Heat / Auto / Fan


Setpoint Adjustment Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control Lo-Mi1-Mi2-Hi
Permit / Prohibit On/Off, Mode, Setpoint
Airflow Direction Horizontal - 60,80,100º swing
Filter Sign Normal/Reset

Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control Lo-Mi1-Mi2-Hi
Permit / Prohibit On/Off, Mode, Setpoint
Airflow Direction Horizontal - 60,80,100º swing
Fault Code 4 Character code - Indicates all unit alarms
Filter Sign -
Room Temperature -

Page 241
BEMS LonWorks Interface
®

LMAP
The Mitsubishi Electric LMAP continues to strengthen the ability of our products to interface with other third party
®
building control systems using the globally recognised and accepted open network protocol Echelon LonWorks .
®
LonWorks was introduced into the building services industry a number of years ago with the aim of establishing
®
itself as the defacto communications standard. Many hundreds of products now exist that utilise the LonWorks
protocol from complete systems like BEMS, lighting, power monitoring and security down to simple sensors
and relay switches.
®
To ensure that our products can connect directly and easily with other LonWorks products, the L-MAP02
®
was designed utilising Echelon MIPS technology and was the first to provide data in the LonWorks
SNVT (Standard Network Variable Type) format.

M-NET

LMAP

Technical Information
®
LMAP LonWorks INTERFACE
FUNCTION LMAP COMPATIBLE WITH
MAX No. OF 50
Honeywell
INDOOR UNITS (G50/AG150/GB50 optional)
Johnson Controls
City Multi
COMPATIBILITY Mr Slim via PAC-SF80MA Realtime Control Systems (LTX51/LTX21 via VCI)
M Series via MAC-399IF
Smart Controls
DIMENSIONS - mm
340x60x360
(WxDxH)

®
LMAP LonWorks INTERFACE
FUNCTION NETWORK VARIABLE NOTES
Control
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control Lo-Mi1-Mi2-Hi
Permit / Prohibit On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)
Filter Sign Normal/Reset
Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control Lo-Mi1-Mi2-Hi
Permit / Prohibit On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)
Fault Code 4 Character code - Indicates all unit alarms
Filter Sign -
Room Temperature -

Page 242
Controls Range 2008
BEMS Modbus Interfaces
Procon IP-32M / IP-50M / IP-100M
TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric
to support their air conditioning systems, the Modbus range has been developed to accommodate the typical
end-user needs as experienced within the UK market.

M-NET

*NOTE 1

ETHERNET PAC-SC50KUA

Modbus
IP-32M
IP-50M
IP-100M

Technical Information

MODBUS INTERFACES
FUNCTION IP-32M IP-50M IP-100M COMPATIBLE WITH
MAX No. OF Trend via Synapsys SXNC200
32 50 100 Cylon
INDOOR UNITS
Satchwell
City Multi City Multi City Multi Crestron (Home automation)
COMPATIBILITY Mr Slim via PAC-SF80MA Mr Slim via PAC-SF80MA Mr Slim via PAC-SF80MA Invensys
M Series via MAC-399IF M Series via MAC-399IF M Series via MAC-399IF Interactive Homes
North BT
DIMENSIONS - mm Andover
270x75x210 270x75x210 270x75x210
(WxDxH) Siemens

MODBUS INTERFACE UNITS - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE MODBUS
BEMS LonWorks® Interface /

Control
On/Off Run/Stop
BEMS Modbus Interfaces

Mode Operation Cool / Dry / Heat / Auto / Fan


Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi

Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
Room Temperature -

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 243
BEMS Modbus Mr Slim Interface
Procon A32M TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric
to support their air conditioning systems, the Modbus range has been developed to accommodate the typical
end-user needs as experienced within the UK market.

PAC-SK81SI

Modbus
A32M

Technical Information

MODBUS MR SLIM INTERFACE


FUNCTION A32M COMPATIBLE WITH
MAX No. OF Trend via Synapsys SXNC200
32 Cylon
OUTDOOR UNITS
Satchwell
Crestron (Home automation)
COMPATIBILITY Mr Slim via PAC-SK81SI Invensys
Interactive Homes
North BT
DIMENSIONS - mm Andover
270x75x210
(WxDxH) Siemens

MODBUS MR SLIM INTERFACE - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE MODBUS
Control
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi

Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
Room Temperature -

NOTE: Not available on SEZ / SLZ

Page 244
Controls Range 2008
BEMS Modbus Splits Interface
Procon A1M TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric
to support their air conditioning systems, the Modbus range has been developed to accommodate the typical
end-user needs as experienced within the UK market.

A1M

Modbus

Technical Information

MODBUS SPLITS INTERFACE


FUNCTION A1M COMPATIBLE WITH
MAX No. OF Trend via Synapsys SXNC200
1 Cylon
INDOOR UNITS
Satchwell
M Series Crestron (Home automation)
COMPATIBILITY Invensys
Mr Slim
Interactive Homes
North BT
DIMENSIONS - mm Andover
72x27x50
(WxDxH) Siemens
BEMS Modbus Mr Slim Interface /

MODBUS SPLITS INTERFACE - OPERATIONAL INFORMATION


BEMS Modbus Splits Interface

FUNCTION NETWORK VARIABLE MODBUS


Control
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi

Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
Room Temperature -

Page 245
BEMS KNX-EIB Interfaces
Procon KNX-EIB-IP-15/100
TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric
to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical
end-user needs as experienced within the UK market.

M-NET

*NOTE 1

ETHERNET PAC-SC50KUA

KNX-EIB
KNX-EIB-IP-15
KNX-EIB-IP-100

Technical Information

KNX-EIB CITY MULTI INTERFACES


FUNCTION KNX-EIB-IP-15 KNX-EIB-IP-100 COMPATIBLE WITH
MAX No. OF ABB
15 100 Intelligent Buildings
INDOOR UNITS
Nova Controls Ltd
City Multi City Multi Siemens
COMPATIBILITY Mr Slim via PAC-SF80MA Mr Slim via PAC-SF80MA
M Series via MAC-399IF M Series via MAC-399IF
DIMENSIONS - mm
107x58x105 107x58x105
(WxDxH)

KNX-EIB CITY MULTI INTERFACE UNITS - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE MODBUS
Control
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi

Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
Room Temperature -

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 246
Controls Range 2008
BEMS KNX-EIB Splits Interface
Procon KNX-EIB-A-1 TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric
to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical
end-user needs as experienced within the UK market.

KNX-EIB-A-1

KNX-EIB

Technical Information

KNX-EIB SPLITS INTERFACE


FUNCTION KNX-EIB-A-1 COMPATIBLE WITH
MAX No. OF ABB
1 Intelligent Buildings
INDOOR UNITS
Nova Controls Ltd
M Series Siemens
COMPATIBILITY
Mr Slim

DIMENSIONS - mm
60x25x48
(WxDxH)

KNX-EIB SPLITS INTERFACE - OPERATIONAL INFORMATION


BEMS KNX-EIB Splits Interface

FUNCTION NETWORK VARIABLE MODBUS


BEMS KNX-EIB Interfaces /

Control
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi

Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
Room Temperature -

Page 247
M2M - Machine 2 Machine Interface
Procon Maxi M2M-IP/50
TM

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices,
Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows
customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment
will be wirelessly connected to the M2M server and use the GPRS network to communicate.

Maxi M2M-IP/50 GB50

MEUK
METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2
M2M GPRS
SERVER

Maxi M2M-IP/50 GB50

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Technical Information

M2M INTERFACE
FUNCTION DESCRIPTION

MAX No. OF INPUTS 22 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

MAX No. OF OUTPUTS 4 (volt free contact)


4 (pulse with modulation)

MAX No. OF INDOOR UNITS 50

COMPATIBILITY City Multi, Mr Slim and M Series

DIMENSIONS - mm (WxDxH) 300x70x350

M2M INTERFACE - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE UP TO 25 GROUPS UP TO 50 GROUPS NOTES
Control
On/Off   Run/Stop
Mode Operation   Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment   Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control  Lo-Mi1-Mi2-Hi
Permit / Prohibit  On/Off, Mode, Setpoint
Airflow Direction  Horizontal - 60,80,100º swing
Filter Sign  Normal/Reset

Monitor
On/Off   Run/Stop
Mode Operation   Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment   Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control  Lo-Mi1-Mi2-Hi
Permit / Prohibit  On/Off, Mode, Setpoint
Airflow Direction  Horizontal - 60,80,100º swing
Fault Code   4 Character code - Indicates all unit alarms
Filter Sign  -
Room Temperature   -

M2M Software Options - Pin Code Activation DEMONSTRATION


M2M - OS Optimised Start for Air Conditioning Visit m2m.mitsubishielectric.co.uk/demo to use the live
M2M - ES Energy Saving Capability demonstration space (login: demo / password: demo)

Page 248
Controls Range 2008
M2M - Machine 2 Machine
Splits Interface
Procon Mini M2M-A/16
TM

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices,
Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows
customers to integrate multiple sites into one network.
The air conditioning units as well as third party equipment
will be wirelessly connected to the M2M server and
use the GPRS network to communicate.
Mini M2M-A/16 A1M A1M

MEUK
METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

M2M GPRS
SERVER

Mini M2M-A/16 A1M A1M

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Technical Information
M2M SPLITS INTERFACE
FUNCTION DESCRIPTION

MAX No. OF INPUTS 8 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

MAX No. OF OUTPUTS 4 (pulse with modulation)

MAX No. OF INDOOR UNITS 16

COMPATIBILITY Mr Slim and M Series via Procon A1M

DIMENSIONS - mm (WxDxH) 255x60x180

M2M SPLITS INTERFACE - OPERATIONAL INFORMATION


M2M Interface / M2M Splits Interface
FUNCTION NETWORK VARIABLE NOTES
Control
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Time Zone Weekly scheduling available
Monitor
On/Off Run/Stop
Mode Operation Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment Cooling 19-30˚C
Heating 17-28˚C
Auto 19-28˚C
Fan Speed Control Lo-Mi1-Mi2-Hi
Fault Code 4 Character code – Indicates all unit alarms
Room Temperature -
Time Zone Weekly scheduling available

M2M Software Options - Pin Code Activation DEMONSTRATION


M2M - OS Optimised Start for Air Conditioning Visit m2m.mitsubishielectric.co.uk/demo to use the live
M2M - ES Energy Saving Capability demonstration space (login: demo / password: demo)

Page 249
M2M-Machine 2 Machine Web Screenshots
MEUK Website Login

M2M is accessible using MEUK website. A username and password is required to monitor
and control sites.

Monitor Active Alarms and Sites Status

All sites are listed with active alarm sites. A site can be selected to monitor each system.

Set Parameters Reports

Indoor unit and third party equipment can be Reports can be generated for analysis.
controlled from the Website.

Dashboard Administration

G50/AG150/GB50 web pages are available for Using the administration level, the phone numbers
the air conditioning units and email of each duty engineer may be set
and activated.

Technical Information

Page 250
Controls Range 2008
G50 Control Panels
Mitsubishi Electric can supply G50 control panels (surface or internally mounted). This allows easy installation.

M-NET

G50 Control Panel

Technical Information

G50 CONTROL PANELS


MODEL No. OF G50 No. OF INDOOR UNITS ROUTER MOUNTED DIMENSIONS (WxDxH)

M2M Web Screenshots / G50 Control Panels


GP50PS1 1 50 NO Surface 600x200x600

GP50PS2 2 100 NO Surface 600x200x600

GP50PS3 3 150 NO Surface 800x250x600

GP50PS4 4 200 NO Surface 800x250x600

GP50PI1 1 50 NO Internally 600x200x600

GP50PI2 2 100 NO Internally 600x200x600

GP50PI3 3 150 NO Internally 800x250x600

GP50PI4 4 200 NO Internally 800x250x600

GP50PSR1 1 50 YES Surface 600x200x600

GP50PSR2 2 100 YES Surface 600x200x600

GP50PSR3 3 150 YES Surface 800x250x600

GP50PSR4 4 200 YES Surface 800x250x600

GP50PIR1 1 50 YES Internally 600x200x600

GP50PIR2 2 100 YES Internally 600x200x600

GP50PIR3 3 150 YES Internally 800x250x600

GP50PIR4 4 200 YES Internally 800x250x600

Page 251
Run / Standby Control Panels
The run/standby panel allows one system to run one week and the other one to run the other week.
If one system fails, the run/standby panel will start the other one. If the temperature is too high,
the panel will also start the 2 systems and enable an audible alarm.

Run / Standby
Control Panel

Technical Information

RUN / STANDBY CONTROL PANELS


MODEL No. OF SYSTEMS RUN STANDBY HIGH TEMP ALARM DIMENSIONS (WxDxH)

PANEL_RS1 2 1 1 YES YES 400x210x600

PANEL_RS2 3 2 1 YES YES 500x210x700

PANEL_RS3 4 3 1 YES YES 500x210x700

Page 252
Controls Range 2008
Energy Monitoring Control Panels
Energy monitoring is key to the compliance with Part L2. To perform energy monitoring; a lot of different
products are required. To optimise the time of installation, Mitsubishi Electric can now supply an energy
monitoring panel with energy meter, current transformers, breakers and the interface to the
Mitsubishi Electric communication network.

Energy Monitoring
Control Panel

M-NET

Power Supply

Technical Information

ENERGY MONITORING CONTROL PANELS


FUNCTION No. OF SYSTEMS MAX RUNNING CURRENT (A) DIMENSIONS (WxDxH)

PANEL_EM100A 1 100 600x210x800

PANEL_EM200A 2 200 600x210x800

Energy Monitoring Control Panels


Run/Standby Control Panels /

Page 253
Controls Range 2008
Split-System A2M Interfaces
The City Multi systems use advanced communication protocol called M-NET. The Split-Systems can be
interfaced to M-NET, allowing compatibility with the main centralised controller (G50, AG150, GB50, TG2000).
An A2M adapter would be required per outdoor unit for Mr Slim and per indoor unit for Mr Slim S Series
or M Series indoor units.

PAC-SF80MA

Technical Information

SPLIT-SYSTEM A2M INTERFACES


FUNCTION PAC-SF80MA MAC-399IF

COMPATIBILITY Mr Slim Outdoor Unit Mr Slim S Series / M Series Indoor Unit

CONNECTION TO Outdoor Unit Indoor Unit

MNET SETTINGS Rotary Switches Dip Switches

DIMENSIONS - mm (WxDxH) 130x15x90 160x55x70


Split-System A2M Interfaces

Page 254
the name Mitsubishi is Mitsubishi Electric Partner Programme
synonymous with excellence Open to all contractors - large or small - the Mitsubishi Electric Par tner Programme offers contractors a
totally new and unique set of benefits. There are two categories within the programme - Accredited Installer
and Business Solutions Partner - these levels being a straight-forward reflection of the Partner’s
stage of growth, with all customers signing up to the programmes standards and committing to
Known the world over, Mitsubishi is a trusted global leader continued training and professional development.

associated with a variety of products and services. Founded in For more information please contact your local sales office
1907, the company known today as Mitsubishi Electric, quickly
rose to the forefront of the air conditioning industry -
a position we still enjoy today.
Mitsubishi Electric Training Options
Unsurpassed air conditioning from Mitsubishi Electric
Air conditioning is an ideal way of controlling the air quality inside any building, large or small. Mitsubishi Electric has four state-of-the-ar t training suites based
Not only does it cool in the summer months but air conditioning can also heat, replacing traditional at different locations around the countr y for your convenience.
heating systems. More and more people today are experiencing the benefits of comfortable working, Providing training for all levels of exper tise, our courses are
living and leisure environments made possible with air conditioning. As market leaders, we pride taught by experienced engineers, with a wealth of knowledge
ourselves in providing high performance, competitive systems with low running costs. and are all CPD accredited.
For bookings please telephone 01707 278797
Protecting the environment
Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as
energy and resource efficiency, minimising ecological impacts of our products and reducing
greenhouse gas emissions. We are the only manufacturer in the industry recognised by
Portfolio 21 as one of the top five companies in the world for our sustainable environmental
policy. All of our factories are also ISO 14001 registered, the international standard that
Systems marked with the ECA logo have an energy label of A or B, are registered on the
specifies a process for controlling and improving a company's environmental performance
Energy Technology List and hence qualify for 100% first year enhanced capital allowances
and with the advent of our Green Gateway Initiative, we strive to constantly promote (whole system cost and ‘reasonable’ cost of installation). For further information please
best practice. go to www.eca.gov.uk

The Forest Stewardship Council (FSC) is an international network promoting responsible


management of the world's forest. The paper this catalogue is printed on supports the
development of responsible forest management worldwide. The wood comes from FSC Nominal conditions cooling: indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.
Nominal conditions heating: indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.
certified, well managed forests, company controlled sources and/or recycled material. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. Winter; indoor 21˚C DB; outdoor -1˚C WB.

Notes: Recommended fuse ratings given throughout this price list are based on British Standard (BS88).
2008 Product Catalogue
Telephone: 01707 282880
Post Sales Technical Support / Spares and Warranty: 0870 3000 300
email: air.conditioning@meuk.mee.com
web: www.mitsubishielectric.co.uk/aircon

UNITED KINGDOM Mitsubishi Electric Europe Air Conditioning Systems Division


Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England.
General enquiries Telephone: 01707 282880 Fax: 01707 278674
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland.
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2008. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V.
The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement.
Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract.
All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

2008 Product Catalogue


Printed in April 2008
SAP No. 214760

A comprehensive range of Air Conditioning


www.greengatewayinitiative.co.uk Systems from Mitsubishi Electric Features Key
Designed by Square Bear Ltd 01604 899099. Square Bear Ltd are committed to using FSC certified paper and printers, wherever possible.

The laminate used on this brochure is environmentally friendly, recyclable and biodegradable

S-ar putea să vă placă și