SV 150/30/50C-100

X-ray Tube Assembly

Data Sheet

Description Technical Data

This compact X-ray tube assembly was developed for use Nominal voltage 150 kV IEC 60613 (2010)
in radiography and fluoroscopy systems. Nominal voltage Fluoroscopy 110 kV

With its small focal spots and large field of view it allows Nominal focal spot values 0.6 1.0 IEC 60336
for superior image quality in undertable fluoroscopy Nominal anode input power (150 Hz / 180 Hz) 30 kW 50 kW IEC 60613 (1989)
applications. (at 300 W average anode input power)
Nominal radiographic anode input power 34 kW 55 kW IEC 60613 (2010)
Filament Heating AC < 50 kHz
Features and customer benefits maximum current 5.1 A 5.0 A
maximum voltage ≈ 10.2 V ≈ 17.5 V
◾◾ 600 kHU anode heat storage capacity for efficient
X-ray examinations Anode Angle 16°
Anode heat storage capacity 450 kJ = 600 kHU IEC 60613 (1989)
◾◾ Focal spots of IEC 0.6 and IEC 1.0 allow excellent
Anode drive frequencies for
image quality
exposure 150 / 180 Hz
◾◾ Large field of view thanks to 16° anode angle fluoro (50 ± 5) Hz
Heat storage capacity of assembly 1.800 MJ = 2.430 MHU IEC 60613
◾◾ High long-term dose yield
Nominal continuous input power 300 W / 450 W IEC 60613 (2010)
◾◾ Excellent quality and reliability (without / with fan) (at ambient temperature < 25 °C)
Radiation Leakage ≤ 0.8 mGy/h IEC 60601-1-3
(at 150 kV, 450 W, 1 m distance)
Inherent filtration permanent filtration: 1.5 mm Al / 75 kV IEC 60522, IEC 60601-1-3
additional filtration: 2 x 0.5 mm (= 1 mm) Al (at 75 kV)
Weight ≈ 27 kg
SV 150/30/50C-100 Heating and cooling curves Rating charts
X-ray Tube Assembly Anode Focal spot IEC 0.6

450 10000 W 500 40 kV


400 5000 W 50 kV
3000 W 400 60 kV
350
2000 W 70 kV
300

Anode heat content, kJ


300

Tube current, mA
1500 W 80 kV
250
1000 W 90 kV
200 200
700 W 100 kV
150 450 W 110 kV
100 300 W 100
120 kV
50 100 W 130 kV
Cooling curve 0
0 140 kV
0,1 1 10 100 0,01 0,1 1
Time, min Loading time, s 150 kV

According to IEC 60613 (1989) According to IEC 60613 (1989)


Anode drive 60 Hz
Thermal anode reference power 300 W

X-ray tube assembly (without fan) Focal spot IEC 1.0

1800
800
40 kV
1600
700 50 kV
1400
Tube assembly heat content, kJ

600 60 kV
150 W
1200
70 kV
200 W 500

Tube current, mA
1000 80 kV
300 W 400
800 90 kV
450 W
300 100 kV
600 600 W
200 110 kV
400 1000 W
120 kV
200 Cooling curve 100
130 kV
0 0
0 2 4 6 140 kV
0,01 0,1 1
Time, h Loading time, s 150 kV

According to IEC 60613 (1989) According to IEC 60613 (1989)


Anode drive 60 Hz
Thermal anode reference power 300 W
2
Dimensional drawings Creating values
is our passion.
Efficiency
is our nature.
Partnership
is our way.

1
Tolerance + 2.0 / - 0.5 F = Focus position
F = Focus position Ref. = Reference axis
Ref. = Reference axis Dimensions are given in mm
Dimensions are given in mm
Trunnion rings, high-voltage cables, stator cables with
shielding and safety switch cables are optionally available.

Types and material numbers

3-phase drive 1-phase drive


Designation SV 150/30/50 C-100 SV 150/30/50 C-100 L
Mat.-No. 4802729 4803255

3
This document is not considered to be a contractual specification. these components into a system using its own brands and labels. Siemens reserves the right to modify the design and specifications
Kindly contact Siemens Healthcare GmbH prior to using this The product names and/or brands referred to are the property of contained herein without prior notice. All rights reserved, particularly
information for equipment design. their respective trademark holders. in connection with patent applications or registrations of utility
model or design.
These components and configurations are not finished medical This document shall not be made available to healthcare
devices. Compliance with all laws and regulations that are applicable professionals or to the general public.
to finished medical devices are the responsibility of the manufacturer
The Siemens Healthcare Business Line Components and Vacuum
of the finished medical device.
Technology is ISO 9001 and ISO 13485 certified, manufactures in
The information in this document contains general descriptions of accordance with the Quality System Regulations (QSR) as defined
the technical options available, which do not always have to be by the U.S. Food and Drug Administration (FDA), and endeavors
present in individual cases. The required features should therefore be to comply with legal requirements concerning the environmental
specified in each individual case at the time of closing the contract. compatibility of its products.
The components are labeled as “Manufactured by Siemens”. The reproduction, transmission or use of this document or its
However, the buyer shall not market the components using the contents is not permitted without express written consent.
“Siemens” brand name and/or trademark. The buyer may integrate Offenders will be liable for damages.

Local Contact Information Publisher for USA


Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc.
Components and Vacuum Technology 40 Liberty Boulevard
Doris-Ruppenstein-Str. 4 Malvern, PA 19355
91052 Erlangen United States of America
Germany
Phone: +49 9131 84-6911
siemens.com/oemproducts

Siemens Healthcare ­Headquarters Legal Manufacturer


Siemens Healthcare GmbH Siemens X-ray Vacuum Technology Ltd., Wuxi
Henkestr. 127 No. 112, Meiyu Road
91052 Erlangen 214028 Wuxi, Jiangsu
Germany P.R. China
Phone: +49 9131 84-0
siemens.com/healthcare

10306993_DS_SV150/30/50C_V01 | CC CV 4792 0617 online | © Siemens Healthcare GmbH, 2017