Sunteți pe pagina 1din 2

Especificaciones del Fabricante - Lorad M-IV

Series, Hologic
MODEL Lorad M-IV Series
X-RAY TUBE
Anode type (X-RAY TUBE) Mo, rotating
Heat capacity, hu (X-RAY
300
TUBE)
Focal spot size, mm (X-RAY
0.1 (small), 0.3 (large)
TUBE)
Target/filter combinations (X-
Mo/Mo, Mo/Rh
RAY TUBE)
Heat dissipation rate, hu/min
60
(X-RAY TUBE)
High-transmission cellular (HTC) grid and FAST paddles (standard
OPTIONAL ATTACHMENTS
on platinum models), various compression paddles, StereoLoc II,
(SHOCK-WAVE
DSM, localization kit, bar-code reader, accessory cabinet, integrated
GENERATOR)
markers, MIS interface
GENERATOR High frequencyconstant potential
Ma range (IMAGING
30, 100
SYSTEM)
Kv range (X-RAY
20increments of 1 kV
GENERATOR)
mAs RANGE (X-RAY TUBE) 3
POWER NEEDED 200-240 VAC ±10%, 35 A, 50/60 Hz
DIMENSIONS (HXWXD) 190 x 64 x 128 (75 x 25 x 50) gantry, 189 x 81 x 43 (74 x 32 x 17)
CM, (IN) (DISPLAY) console
WEIGHT, kg (lb) (DISPLAY) 384 (800) gantry, 91 (200) console
SCREEN FILM
CAPABILITIES (X-RAY Up to 3, programmable
TUBE)
RADIATION SHIELD (X-RAY
Yes
TUBE)
L x w, cm (in) (CONTROL
190 x 80 (75 x 31)
CONSOLE)
Thickness (DIMENSIONS, cm
0.5 mm Pb equivalent
(in))
Bucky (GENERAL
18 x 24 cm, 24 x 30 cm
RADIOGRAPHY)
STEREOTACTIC UNIT
Optional StereoLoc II
(POSITIONING ASSEMBLY)
POSITIONING ASSEMBLY
Collimation (POSITIONING
Automatic
ASSEMBLY)
18 x 24 cm (POSITIONING
Automatic
ASSEMBLY)
24 x 30 cm (POSITIONING
Automatic
ASSEMBLY)
Vertical axis, cm (in)
63.5-140 (25-55) motorized
(POSITIONING ASSEMBLY)
Sid, cm (POSITIONING
65
ASSEMBLY)
Motion locks (POSITIONING
Electromagnetic, fail-safe
ASSEMBLY)
ROTATION, °
(ILLUMINATION LEVEL, +195, -150, digital readout
maximum ft-candles)
Scale guide (POSITIONING
Digital readout
ASSEMBLY)
FILM ID (X-RAY TUBE) Integrated AutoFilm ID
MAGNIFICATION UNIT (X-
1.8x
RAY TUBE)
COMPRESSION METHOD Manual, motorized in both directions; precomp, full comp, dual comp
(X-RAY TUBE) modes; dual footswitch
Force, newtons (X-RAY
89-178 (full comp), 300 (manual)
TUBE)
LABEL PRINTER (X-RAY
Optional
TUBE)
RADIATION OUTPUT
Mr/sec @ 28 kvp
>1,500, 60 cm
(RADIATION OUTPUT)
Grid ratio (IMAGING
HTC or 5:1 linear, focused standard
SYSTEM)
AEC DETECTOR
Solid-state
(POSITIONING ASSEMBLY)
Variable parameters
Automatic time, automatic kV, automatic filter
(POSITIONING ASSEMBLY)
18 x 24 cm SRL 2000 Bucky; 24 x 30 cm SRL 2000 Bucky; HTC
OTHER ATTRIBUTES
grids; FAST paddles, various paddles; magnification table; face
(Interference compensation)
shield; radiation shield; AutoFilm ID; dualfunction footswitch.
FDA CLEARANCE
Yes
(Interference compensation)
CE MARK (MDD)
Yes
(Interference compensation)
MARKETING REGION
Worldwide
(Interference compensation)

S-ar putea să vă placă și