Sunteți pe pagina 1din 4

PFP (RLE)

EN-PFP-Issue-2_03-2018

The compact lightweight


The compact lightweight

The ultra compact PFP completes the The new impeller is specifically selected for
Nicotra Gebhardt offer optimum performance in the PFP application:

Beyond the existing RLE range NG group has decided to develop an J Lightweight high-efficiency aluminium impeller.
additional range of permanent magnet external-rotor motor (EC) plug J Optimised for medium pressure applications.
fans. J Reduced losses due to motor influence.
J Low interference loss with fan enclosure.
The PFP with outstanding combination of efficient drive system and
aerodynamics is the ideal solution for medium-pressure applications. The drive system of the PFP fans is one more
The PFP completes the offer of existing low pressure and high new development built on the success of DDMP
pressure high efficiency fans. experience.

All fan applications can now find the perfect solution ErP
within Nicotra Gebhardt product range. 2020

PFP range - Planned expansion


of the
PFP performance envelope
range - Planned expansion of the performance envelope
1400

1200
1.35 kW - 1-Ph

1000 2.4 kW - 3-Ph

4.0 kW - 3-Ph

800
psF [Pa]

600

400

200

0
0 2500 5000 7500 10000 12500 15000 17500 20000 22500
qv [m3/h]

26
The new motor combines a numbers of The new advanced controller
outstanding features: characteristics:

J Compact external-rotor motor. J All the single-phase models comply with EMC requirements for class
J  Aerodynamically optimised. C1; three-phase models shall comply with the EMC requirements for
J  High efficiency motor with neodymium magnets. class C2 (emissions) / C3 (immunity).
J  Integrated controller. J  Can operate in PID mode, adjusting fan speed to keep the
measurement of a system parameter to the desired value, via 2
analogue inputs, and an external transducer.
J  Operation at constant flow-rate can be achieved using the PID mode
and a pressure transducer, connected with the pressure probe
provided on the inlet nozzle.
J  speed control via external voltage signal.
J  ModBus / RS485 serial interface.
J  10V and 24V power supply for external transducers.
J  Master & slave mode, for stable operation in parallel.

PFP range 2018


Size
280 315 355 400 450 500 560 630
Motor

1.35 kW / 1 Ph In production

2.4 kW / 3 Ph Available 2018

4 kW / 3 Ph Available 2018

Also available RLE Evo

J External rotor motor (EC)


J  Controlled with integrated electronics
J  Impeller siezes 250 - 630 mm
J  Max. motor input 3.5 kW
EN-PFP-2_03-2018
Nicotra Gebhardt worldwide

AUSTRALIA
65 Yale Drive, nicotra-gebhardt.com
Epping, VIC 3076
Phone +61 3 9017 5333
Fax +61 3 8401 3969
E-mail info@nicotra.com.au

BELGIUM
Allée des Artisan,18
4130 Esneux
Phone +32 ((0)42288580
Fax +32 (0)42288580
E-mail info@nicotra.be

CHINA
88 Tai‘An Road, XinQiao, ShiJi, Panyu
Guangzhou 511450
PR CHINA
Phone +86 (0)20-2293 5700
Fax +86 (0)20-2293 5701
E-mail sales@nicotra-china.com

FRANCE
Leader's Park Bat A1
3 chemin des Cytises
69340 Francheville
Phone +33 (0)4 72 79 01 20
Fax +33 (0)4 72 79 01 21
E-mail f.burgevin@nicotra-gebhardt.com

GERMANY
Gebhardtstraße 19-25
74638 Waldenburg
Phone +49 (0)7942 101 0
Fax +49 (0)7942 101 170
E-mail info@nicotra-gebhardt.com

GREAT BRITAIN MALAYSIA SWEDEN


Unit D, Rail Mill Way Lot 1799, Jalan Balakong Box 237
Parkgate Business Park Taman Perindustrian Bukit Belimbing Kraketorpsgatan 30
Rotherham 43300 Seri Kembangan 43153 Mölndal
South Yorkshire Selangor Phone +46 (0)311302610
S62 6JQ Phone +603 8961-2588 E-mail info.se@nicotra-gebhardt.com
Phone +044 01709-780760 Fax +603 8961-8337
Fax +044 01709-780762 E-mail info_malaysia@nicotra-gebhardt.com THAILAND
E-mail sales@nicotra.co.uk 6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road,
SPAIN Kwang Jomthong, Khet Jomthong,
INDIA C/ Jamaica, 5 Bangkok 10150
Plot no 28F & 29, Sector-31,Kasna, Apdo. Correos 5077 Phone +662 476-1823-6
Greater Noida-201 308 U.P (India) 28806 Alcalá de Henares Fax +662 476-1827
Phone +91 120 4783400 Phone +34 918-846110 E-mail sales@nicotra.co.th
Phone +91 22 65702056 (Mumbai) Fax +34 918-859450
Phone +91 80 25727830 (Bangalore) E-mail info@nicotra.es UNITED STATES
E-mail info@nicotraindia.com PO BOX 900921
SINGAPORE Sandy, Utah 84090
ITALY 3, Science Park Drive, # 04-07, The Franklin Phone 001(801) 733-0248
Via Modena, 18 Singapore Science Park 1 Fax 001(801) 315-9400
24040 Zingonia (BG) Singapore 118223 Mobile 001(801) 682 0898
Phone +39 035 873 111 Phone +65 6265 1522 E-mail mike.sehgal@gebhardtfans.com
Fax +39 035 884 319 Fax +65 6265 2400 http://www.gebhardtfans.com/
E-mail info@nicotra-gebhardt.com E-mail info_singapore@nicotra-gebhardt.com

Nicotra Gebhardt Germany Nicotra Gebhardt Italy

Nicotra Gebhardt GmbH Nicotra Gebhardt S.p.A


Gebhardtstraße 19-25 Via Modena, 18
74638 Waldenburg 24040 Zingonia (BG)
Germany Italy
Phone +49 (0)7942 101 0 Phone +39 035 873 111
Fax +49 (0)7942 101 170 Fax +39 035 884 319
E-mail info@nicotra-gebhardt.com E-mail info@nicotra-gebhardt.com

24

S-ar putea să vă placă și