echangeur courant parallele

in out
t1 60 25
t2 18 22

T1-T2 in 42
T1-T2 iout 3

top 39
back 14
ln back 2.639057

r 14.778

echangeur contre courant

in out
t1 60 25
t2 18 23

T1in-T2 out 37
T1out-t2in 7

ln 1.665008

LMTD 18.01793
Q 0.0084
Cp 4176
Ro 991
T1 in 60
T1 out 25

P 1216694

q2 0.060389
ro2 996
cp2 4178
t2 in 18
delta T 4.841686

T2 22.84169

K 4500

S 15.02092
HEAT EXCHANGEUR CALCULATION COUNTER CURRENT

HOT FLUIDE COLD FLUIDE


DEFINITION DATA UNITS
FRESH WATER SEA WATER

Flow rate Q m3/s 0.008 0.220


Inlet Temp T in celsius 60.000 18.000
Outlet Temp T out celsius 25.000 19.286 Calcul
Density Ro Kg/m3 991.200 996.700
specific heat Cp Kj/(kg.K) 4176.000 4178.000
Thermal conduct W/(m.K) 0.637 0.608
Viscosity cP 0.632 0.872

Mass flow rate Kg/s 8.058 219.274


Heat LOAD W 1177823.929 1177823.929
Delta T 35.000 1.286

LMTD 19.15
coef K W/m2.K 4500.00
Effective area S m2 13.67