Largeur du mur 25 cm
C = 5 cm
Qu = 0.80 MPa , dans ce cas Qc = Qu/2
Beton 25 MPa
Aciers 500 MPa
• charges permanentes: G = 300 kN/m
• charges d'exploitation: Q= 150 kN/m
• fissuration non préjudiciable
Calcul de la surface :
S ≥Nu/ qu
Nu = 1.35G+1.5Q
Nu = (1.35 x 300) + (1.5 x 150)
Nu = 0.630 M/m
Calcul de qc
qc= qu/2
qc = 0.8/2
qc = 0.4 MPa
Calcul de B
B≥ Nu/ qc
≥0.63/0.4
≥1.58
B = 1.60 m
Calcul de h
h = d+0.05
= 0.4 +0.05
h = 0.40 m
2/ Vérification de la semelle
NU+1.35(Pps+Ppr)
σsol = S
0.63+1.35(0.016+0.0108)
σsol = (1.60x1.00)
qc = 0.4 MPa
Calcul de B
B≥ 1.10 Nu/ qc
≥ 1.10 x 0.63/0.4
≥1.732 m
B = 1.75 m
Calcul de h
h = d+0.05
= 0.4 +0.05
h = 0.45 m
2/ Vérification de la semelle
NU+1.35(Pps+Ppr)
σsol = S
0.63+1.35(0.020+0.0105)
σsol = (1.75x1.00)
qc = 0.40 MPa
Vérifications
Ls = 44 ϕl pour Fe 500