Delta Power Meter


DPM Series

w w w. d e l t a w w. c o m
Product Introduction
Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and
power quality parameters, including power factor, harmonics, and current / voltage unbalance with
Features
functions such as off-limit alarms and history logs. It provides exceptional communication quality and High Precision Power Measurement
monitoring functions that are especially suitable for sectors where power quality is critical. ►► Highly
precise measurement of bidirectional electrical energy and power parameters, meeting Class 0.5S of
IEC 62053 and CNS14607 standards.
Specifications ►► Supports
power quality measurement, including total and individual harmonic distortion, voltage and current
Model Name DPM-C530A DPM-C520 DPM-D520I unbalance, and more.

Product Appearance Large Screen LCD


DPM-C530A
►► White-light widescreen LCD with resolution of 198x160 dots.
Accuracy Class
Active Energy (IEC 62053-22) Class 0.5S Class 0.5S Class 0.5S
Measurement Accuracy
Current 1A/ 5A 1A/ 5A 63 A
Voltage ● ● ●

Frequency ● ● ●
■■ Visibility better than segment-type LCD
Active, Reactive, and Apparent Power ● ● ●

Power Factor ● ● ●
Ptot 123456.78 kW
Active, Reactive, and Apparent Energy ● ● ●

Interval Energy ● - ● Etot 123456.78 kVARh

Demand Values
Current ● - ●

Power ● - ●

Calculation Mode Block - Block


Multiple Rate
Interval Numbers 8 groups - 8 groups Easy Operation and Installation
Power Quality Measurement ►► Easy installation and disassembling with two fixing mounts, no screws or extra tools required.
Current / Voltage Unbalance ● ● ●
►► Built-in RS-485 communication port supports MODBUS communication.
Total Voltage Harmonic Distortion ● ● ●
►► Transmission of all measurement values to the PLCs via communication.
Total Current Harmonic Distortion ● ● ●

Individual Current / Voltage Harmonic Distortion 2 ~ 31 - -


Data Recording HMI SCADA Server
Max. / Min. of Instantaneous Values With Timestamp ● ● ●

Selectable 17 Selectable 17
Data Logs Type -
measurement values measurement values
Data Logs Recording Duration Up to 2 months - Up to 2 months
Ethernet
Alarms History 500 - 500
Alarms
Alarm Types 29 10 29
PLC
Communication
RS-485 Interface ● ● ●

Parameter Grouping ● ● ●

MODBUS MODBUS RTU/ASCII MODBUS RTU MODBUS RTU/ASCII MODBUS RTU


* Min. / max. of instantaneous : Phase voltage, line voltage, current, frequency, total 3 - phase active power, total 3 - phase reactive power, total 3 - phase apparent power, total power factor, total voltage
harmonic distortion, total phase voltage harmonic distortion, total current harmonic distortion, phase voltage unbalance, 3 - phase voltage unbalance, 3 - phase current unbalance
* Alarm types: Over-current, under-current, over natural current, over line voltage, under line voltage, over phase voltage, under phase voltage, over voltage unbalance, over current unbalance, over active
power, over reactive power, over apparent power, power factor (lead), power factor (lag), over current demand, over active power demand, over reactive power demand, over apparent power demand,
over frequency, under frequency, over total voltage harmonic distortion, over total current harmonic distortion, phase lose, meter restore factory, phase sequence reversal, over DUI, over EU DPM-C530A DPM-D520I
* Data log: Phase voltage, line voltage, current, natural current, power factor, displacement power factor, total active power, total reactive power, total apparent power, positive active energy, reversed active
energy, positive reactive energy, reversed reactive energy, positive apparent energy, reversed apparent energy, total voltage harmonic distortion, total current harmonic distortion

1 2
Features
Event Alarms and History Logs PC-based Configuration Software
DPM-C530A & DPM-D520I ►► Utilizing
DPMSoft software through MODBUS communication for power meter setup and data acquisition
►► Keeps max. 2 months of power and electricity energy measurement values for history analysis. provides easy power management and analysis.
Up to 17 power parameters selectable for recording different time intervals (ex. recording PC Notebook
17 electricity parameters every 5 minutes, for up to 2 months). 29 types of built-in event alarms for
up to 500 event records.

DPM-C520
►► 10 types of built-in event alarms.
500
►► Front LED indicators for real-time alarms. Alarm messages
with time stamps can be transmitted to PLCs via communication.

Auto Meter Reading


IFD6500
DPM-C530A & DPM-D520I
►► Two built-in individual data registers record active / reactive energy in a certain given time lapse when triggered
RS - 485
through communication.

Two individual
time lapse settings
DPM

START START

END

END

Parameter Grouping
►► Groupingthe measurands for faster data transmission and reading by the PLCs improves the efficiency and
performance of data transmission.
SCADA Server

Current
Voltage
Energy
RS-485

Demand

Power
System
DPM

3 4
Applications Common Technical Data
►► Power Monitoring and Control, Energy Management Systems, Medium / Low Voltage Power Distribution Model Name DPM-C530A DPM-C520 DPM-D520I
Panels, Building Energy Management Systems, Factory Energy Management Systems, Factory Automation
Electrical Characteristics
and Intelligent Buildings.
Current ± 0.2% ± 0.5%
Energy Management Systems Ethernet
Voltage ± 0.2% ± 0.5%
Programmable Logic Power ±0.5%
Controller Measurement
Active Energy IEC 62053-22 Class 0.5S
Human Accuracy
Machine MODBUS Reactive Energy ±0.5%
Interface Power Factor ±0.5%
Power Meter
Frequency ±0.5%
Active Front End Wiring Method 1P2W, 1P3W, 3P3W, 3P4W 3P3W, 3P4W
Integrated Programmable
Elevator Logic Wire voltage: 35 ~ 690 VAC (L-L)
Programmable Drive Controller
Voltage
AC Motor Drive Phase voltage: 20 ~ 400 VAC (L-N)
Logic
Controller AC Reactor Input Current 1A/ 5A 63 A
Frequency Range 45 ~ 70 Hz
Chiller
Permanent Cooling Tower 80 ~ 265 VAC (Max. power consumption 4.6 W)
Power Supply
7F Magnetic 100 ~ 300 VDC
6F Synchronous
Motor Communication
5F
Light RS-485 Interface Baud rate 9600 / 19200 / 38400 bps, MODBUS
4F
AC Motor Drive
3F
AC Motor Mechanical Characteristics
Drive
2F HJGH
K
HJGH
HJGH
HJGH
HJGH
K

NVH FDH
K
K
K NVH FDH
NVH FDH
NVH FDH
NVH FDH
22 SDF
02 SDF
18 SDF
13 SDF
HJGHF
HJGUTYRK
HDRWSJGK
HJGK
GFY
457FY
GJDFGDHFY
GHG45FY
IP Degree of Front Display IP54 -
Light
13 SDF

Protection
HJGK
GHG45FY

Air Handling
1F
Unit
Meter Body IP20 IP20
Pump Dimensions ( W x H x D ) 96 x 96 x 95.4 mm 126 x 90 x 67.4 mm
Lighting System Elevator HVAC System Environmental Conditions
Operating Temperature -20 ℃ ~ +70 ℃
Storage Temperature -30 ℃ ~ +80 ℃
Human Machine
Factory Automation Interface Relative Humidity ~ 95% RH
Altitude Below 2000 m
Electromagnetic Compatibility
Programmable Electrostatic Discharge IEC 61000-4-2
Logic Controller
Immunity to Radiated Fields IEC 61000-4-3
MODBUS Immunity to Fast Transients IEC 61000-4-4
Immunity to Impulse Waves IEC 61000-4-5
Conducted Immunity IEC 61000-4-6
Immunity to Magnetic Fields IEC 61000-4-8
Immunity to Voltage Dips IEC 61000-4-11

Temperature Pressure Timer  /  Counter  /   AC Servo Power Meter AC Motor Radiated Emissions FCC part 15 EN 55011 Class A
Controller Sensor Tachometer Drive Drive Conducted Emissions FCC part 15 EN 55011 Class A
Harmonics Emissions IEC 61000-3-2
Wave Soldering Semi-finished Conformal
Product Testing Coating Flicker Emissions IEC 61000-3-3
Fluxing
Drying
Hand Insertion Safety
Europe CE, IEC 61010 -

5 6
Dimensions (Units: mm) Wiring Diagrams
Panel Type Panel Type
• 3-Phase 3-Wire, Δ-connection • 3-Phase 4-Wire, Y-connection
• 1-Phase 2-Wire (1CT)
90 (3CT, no PT) (3CT, no PT)
90

A B C N

A B C N

A N
71.0
71

I1+ V1 V2 V3 Vn
I1+ V1 V2 V3 Vn
I1+ V1 V2 V3 Vn
I1-
I1-
I1-
22.1
22.1

I2+
I2+
I2+
I2-
I2-
I2- I3+
I3+
I3+ I3-
I3-
I3-
Load
Load Load

96
96 93.1
93.1 Spec. Label

• 3-Phase 3-Wire, Δ-connection • 3-Phase 4-Wire, Y-connection


• 1-Phase 3-Wire (2CT)
(2CT, no PT) (2CT, 3 PT)

A B C N
A B C N
96.0

90.0
96
A B N
96

I1+ V1 V2 V3 Vn

I1+ V1 V2 V3 Vn I1- I1+ V1 V2 V3 Vn

I1- I2+ I1-

I2- I2+
I2+

I3+ I2-
I2-

I3- I3+
I3+

DIN Rail Type


I3-
I3-
Load Load

126
Load
126.0 64
64.0
45.3

• 3-Phase 3-Wire, Δ-connection • 3-Phase 4-Wire , Y-connection


(3CT, 2PT) (3CT, 3 PT)
A B C N
A B C N
90.0

93.3
93.3
90

I1+ V1 V2 V3 Vn I1+ V1 V2 V3 Vn

I1- I1-

I2+ I2+

I2- I2-

I3+ I3+

I3- I3-

67.4
67.4
Load Load

7 8
Wiring Diagrams Optional Accessories
DIN Rail Type Model
Primary Secondary Max. Measurement
Sizes (Units: mm)
Current Current Load Accuracy
• 3-Phase 3-Wire, CT Connection • 3-Phase 4-Wire, CT Connection Outer
115 x 89 x 51 40
C B A N C B A Frame
DCT - S301C 100A 5A 1.5VA 1.0% 34

Inner
32 x 21 x 32 P1
Frame
Outer

115
32
115 x 89 x 51
IA+ V1 V2 V3 Vn
+ V1
Frame
V2 V3 Vn
DCT - S211C 200A 5A 1.0VA 0.5% P1

IA- Inner
IA- 32 x 21 x 32 21 32

IB+
Frame 89 50
IB+ 67
Outer
IB-
IB-
115 x 89 x 51
Frame
IC+ DCT - S221C 300A 5A 1.5VA 0.5%
IC+ Inner
32 x 21 x 32
IC- IC- Frame
Outer
115 x 89 x 51 51
Load Load Frame 50 34

DCT - S231C 400A 5A 2.5VA 0.5%


Inner
32 x 21 x 32
Frame

145
80
• 3-Phase 3-Wire, Direct Connection • 3-Phase 4-Wire, Direct Connection Outer
145 x 116 x 51
Frame
C B A
DCT - S241C 500A 5A 2.5VA 0.5% P1
N C B A Inner
80 x 50 x 32 79.5 32

Frame 116 50
67
Outer
145 x 116 x 51
Frame
IA+ V1 V2 V3 Vn DCT - S251C 600A 5A 2.5VA 0.5%
IA+ V1 V2 V3 Vn Inner
IA- 80 x 50 x 32
IA- Frame
IB+
IB+ Outer
145 x 116 x 51
IB- Frame 51.6
IB-
DCT - S261C 750A 5A 3.0VA 0.5% 80 35

IC+
Inner
IC+ 80 x 50 x 32
Frame
IC- IC-
Outer

196
122
145 x 116 x 51
Frame
Load Load DCT - S271C 1000A 5A 5VA 0.5%
Inner P1

80 x 50 x 32
Frame 109.2 32
146 50
Outer 67
196 x 146 x 51
Frame

How to Connect DPMSoft PC Notebook DCT - S281C 1500A 5A 7.5VA 0.5%


Inner
122 x 80 x 32
Frame

PIN Definition Outer


250 x 186 x 1.4 51.4

4 D+ Frame 81 35

DCT - S291C 2000A 5A 10VA 0.5%


5 D- Inner P1

160.5 x 81 x 32
Frame
Outer

250
160.5
DPM 250 x 186 x 51.4
8←1 Frame
USB DCT - S2A1C 2500A 5A 15VA 0.5%
Inner P1

160.5 x 81 x 32
Frame 121 32

IFD6500 186 50

RJ - 45 Outer 67

PIN 5 250 x 186 x 51.4


Frame
DCT - S2B1C 3000A 5A 20VA 0.5%
PIN 4
Inner
160.5 x 81 x 32
Frame

* All models are CE-certified but not UL-certified.

9 10
Industrial Automation Headquarters
Delta Electronics, Inc.
Taoyuan Technology Center
No.18, Xinglong Rd., Taoyuan Dist.
Taoyuan City 33068, Taiwan
TEL: 886-3-362-6301 / FAX: 886-3-371-6301

Asia
Delta Electronics (Jiangsu) Ltd.
Wujiang Plant 3
1688 Jiangxing East Road,
Wujiang Economic Development Zone
Wujiang City, Jiang Su Province,
People's Republic of China (Post code: 215200)
TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290

Delta Greentech (China) Co., Ltd.


238 Min-Xia Road, Pudong District,
ShangHai, P.R.C.
Post code : 201209
TEL: 86-21-58635678 / FAX: 86-21-58630003

Delta Electronics (Japan), Inc.


Tokyo Office
2-1-14 Minato-ku Shibadaimon,
Tokyo 105-0012, Japan
TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211

Delta Electronics (Korea), Inc.


1511, Byucksan Digital Valley 6-cha, Gasan-dong,
Geumcheon-gu, Seoul, Korea, 153-704
TEL: 82-2-515-5303 / FAX: 82-2-515-5302

Delta Electronics Int’l (S) Pte Ltd


4 Kaki Bukit Ave 1, #05-05, Singapore 417939
TEL: 65-6747-5155 / FAX: 65-6744-9228

Delta Electronics (India) Pvt. Ltd.


Plot No 43 Sector 35, HSIIDC
Gurgaon, PIN 122001, Haryana, India
TEL : 91-124-4874900 / FAX : 91-124-4874945

Americas
Delta Products Corporation (USA)
Raleigh Office
P.O. Box 12173,5101 Davis Drive,
Research Triangle Park, NC 27709, U.S.A.
TEL: 1-919-767-3800 / FAX: 1-919-767-8080

Delta Greentech (Brasil) S.A


Sao Paulo Office
Rua Itapeva, 26 - 3° andar Edificio Itapeva One-Bela Vista
01332-000-São Paulo-SP-Brazil
TEL: +55 11 3568-3855 / FAX: +55 11 3568-3865

Europe
Delta Electronics (Netherlands) B.V.
Eindhoven Office
De Witbogt 20, 5652 AG Eindhoven, The Netherlands
TEL: +31 (0)40-8003800 / FAX: +31 (0)40-8003898

*We reserve the right to change the information in this catalogue without prior notice.

DELTA_IA-SI_DPM_C_EN_20160914