Sunteți pe pagina 1din 113

Heating

Technical Data

ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

TABLE OF CONTENTS
ERLQ-CV3

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
3 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
4 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Cooling Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Certification Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
6 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
7 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
8 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103


Sound Power Spectrum Quiet Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

10 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

11 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109


• Heating • ERLQ-CV3 1
• Outdoor Unit • ERLQ-CV3

1 Features

h i t n l U A 3 r gVn o nC io i - kd tQ it aL aueR DEH•O Outdoor unit extracts heat from the outdoor air, even at -25°C • Inverter controlled swing compressor

Guaranteed Inverter
operation down
to -25°C

2 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


EHBH04CB3V/ EHBH08CB9W/ EHBH08CB3V/ EHBH08CB9W/ EHBH08CB3V/ EHBH11CB3V/
3
2-1 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ006CV3 ERLQ008CV3 ERLQ008CV3 ERLQ011CV3
Heating capacity Min. kW 1.80 (1) -
Nom. kW 4.40 (1) / 4.03 6.00 (1) / 5.67 (2) 7.40 (1) / 6.89 (2) 11.2 (1) / 11.0
(2) (2)
Max. kW 5.12 (1) / 4.90 8.35 (1) / 7.95 (2) 10.0 (1) / 9.53 (2) 8.60 (3) / 8.60 2
(2) (4)
Power input Heating Nom. kW 0.870 (1) / 1.27 (1) / 1.59 (2) 1.66 (1) / 2.01 (2) 2.43 (1) / 3.10
1.13 (2) (2)
Max. kW - 3.13 (3) / 4.10
(4)
COP 5.04 (1) / 3.58 4.74 (1) / 3.56 (2) 4.45 (1) / 3.42 (2) 4.60 (1) / 2.75
(2) (3) / 3.55 (2) /
2.10 (4)
Pump Nominal ESP unit Heating kPa 53.0 (5) / 56.0 45.0 (5) / 48.0 (6) 33.0 (5) / 38.0 (6) 37.0 (7) / 39.0
(6) (8)
Water side Heat Water flow rate Heating Nom. l/min 12.6 (5) / 11.6 17.2 (5) / 16.3 (6) 21.2 (5) / 19.8 (6) 32.1 (7) / 31.5
exchanger (6) (8)
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination No
heater
Low-temperature heat pump No
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 40.0 41.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61.0 62.0 64.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 5,400
(outdoor)
Brine/water to water Rated water/brine m³/h 0.00 -
unit flow
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.00 0.055
heater mode)
Poff (Off mode) kW 0.0080 0.055
Psb (Standby mode) kW 0.0080 0.055
Pto (Thermostat off) kW 0.0060 0.0070 0.0080 0.057
Integrated NOx emission mg/ 0.00
supplementary kWh
heater Psup kW 3.00 9.00 3.00 9.00 3.00
Type of energy input Electrical

• Heating • ERLQ-CV3 3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.20 3.22 3.23 3.09
water outlet 55°C Annual kWh 2,356 3,369 4,064 6,260
energy
consum
ption
2 Annual Gj 8.48 12.1 14.6 22.6
energy
consum
ption
(GCV)
ηs % 125 126 120
(Season
al space
heating
efficienc
y)
Prated kW 3.70 5.30 6.40 9.99
at -10°C
Seasonal space A++ A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/ COPd 2.03 2.02 1.98 1.99
-8°CWB)
Pdh kW 3.36 4.50 5.47 8.83
PERd % 81.2 80.8 79.2 79.6
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 3.08 3.17 3.24
1°CWB)
Pdh kW 2.00 4.43 3.43 5.28
PERd % 123 127 130
C Cdh (Degradation 0.990 0.950
Condition heating)
(7°CDB/ COPd 4.27 4.20 4.31
6°CWB) Pdh kW 2.77 3.51 3.50 4.47
PERd % 171 168 172
D Cdh (Degradation 0.990 0.930
Condition heating)
(12°CDB COPd 6.33 5.82 6.41
/
Pdh kW 2.65 3.28 5.37
11°CWB)
PERd % 253 233 256
Tol COPd 1.80 1.74 1.66 1.79
(temperat Pdh kW 3.76 4.62 6.18 9.08
ure
PERd % 72.0 69.6 66.4 71.6
operating
TOL °C -10.0
limit)
WTOL °C 55.0
Rated Psup (at kW 0.00 0.680 0.220 0.910
heat Tdesign
output -10°C)
supplem
entary
capacity
Tbiv COPd 1.80 1.74 1.66 1.99
(bivalent Pdh kW 3.76 5.09 6.18 8.83
temperat PERd % 72.0 69.6 66.4 79.6
ure)
Tbiv °C -10.0 -9.00 -10.0 -7.00

4 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 2,133 2,306 3,088 6,740
3
outlet 55°C energy
consum
ption
Annual Gj 7.68 8.30 11.1 24.3
energy 2
consum
ption
(GCV)
ηs % 107 110 95.0
(Season
al space
heating
efficienc
y)
Prated kW 2.39 2.60 3.56 6.99
at -22°C
Warm climate water General Annual kWh 1,168 1,491 1,904 2,630
outlet 55°C energy
consum
ption
Annual Gj 4.20 5.37 6.85 9.47
energy
consum
ption
(GCV)
ηs % 186 182 178 125
(Season
al space
heating
efficienc
y)
Prated kW 4.27 5.30 6.59 7.58
at 2°C

• Heating • ERLQ-CV3 5
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 4.52 4.29 4.34 3.98
water outlet 35°C Annual kWh 1,980 2,540 3,489 5,380
energy
consum
ption
2 Annual Gj 7.13 9.14 12.6 19.4
energy
consum
ption
(GCV)
ηs % 178 169 171 156
(Season
al space
heating
efficienc
y)
Prated kW 4.40 5.34 7.40 11.2
at -10°C
Seasonal space A++
heating eff. class
A COPd 3.01 2.69 2.63
Condition Pdh kW 4.01 4.72 6.68 8.88
(-7°CDB/
PERd % 120 108 105
-8°CWB)
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 4.41 4.24 4.05
1°CWB)
Pdh kW 2.40 3.90 6.03
PERd % 176 170 162
C Cdh (Degradation 0.980 1.00 0.940
Condition heating)
(7°CDB/ COPd 5.85 5.75 6.77
6°CWB)
Pdh kW 1.70 2.59 5.74
PERd % 234 230 271
D Cdh (Degradation 0.980 0.920
Condition heating)
(12°CDB COPd 7.71 7.27 8.97
/ Pdh kW 2.04 2.61 6.50
11°CWB)
PERd % 308 291 359
Tol COPd 2.61 2.29 2.34
(temperat Pdh kW 4.36 4.70 6.81 8.76
ure PERd % 104 91.6 93.6
operating
TOL °C -10.0
limit)
WTOL °C 35.0
G COPd 0.00 -
Condition Pdh kW 0.00 -
(- PERd % 0.00 -
15°CDB/
-)
Tbiv COPd 2.61 2.47 2.82
(bivalent Pdh kW 4.36 4.93 7.14 9.09
temperat
PERd % 104 98.8 113
ure)
Tbiv °C -10.0 -8.00 -5.00
Rated Psup (at kW 0.040 0.640 0.590 2.44
heat Tdesign
output -10°C)
supplem
entary
capacity

6 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 1,450 2,040 2,480 6,430
3
outlet 35°C energy
consum
ption
ηs % 151 153 151 148
(Season 2
al space
heating
efficienc
y)
Prated kW 2.28 3.25 3.89 10.3
at -22°C
Qhe Gj 5.20 7.34 8.91 23.1
Annual
energy
consum
ption
(GCV)
Warm climate water General Annual kWh 905 1,270 1,570 1,950
outlet 35°C energy
consum
ption
Annual Gj 3.26 4.56 5.67 7.02
energy
consum
ption
(GCV)
ηs % 269 259 251 192
(Season
al space
heating
efficienc
y)
Prated kW 4.81 6.40 7.68 9.06
at 2°C
Domestic hot water General Function to fix water heating Yes -
heating during off peak hours
Average climate ηwh (water heating % -
efficiency)
Cold climate ηwh (water heating % -
efficiency)
Warm climate ηwh (water heating % -
efficiency)

CONNECTABLE INDOOR UNITS


EHBH11CB9W/ EHBH16CB3V/ EHBH16CB9W/ EHBH16CB3V/ EHBH16CB9W/
2-2 Capacity and Power input ERLQ011CV3 ERLQ014CV3 ERLQ014CV3 ERLQ016CV3 ERLQ016CV3
Heating capacity Nom. kW 11.2 / 11.0 14.5 / 13.6 16.0 / 15.2
Max. kW 8.60 / 8.60 10.6 / 10.8 11.4 / 10.9
Power input Heating Nom. kW 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66
Max. kW 3.13 / 4.10 4.00 / 5.19 4.32 / 5.22
COP 4.60 / 2.75 / 3.55 / 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09
2.10
Pump Nominal ESP unit Heating kPa 37.0 / 39.0 49.0 / 57.0 33.0 / 42.0
Water side Heat Water flow rate Heating Nom. l/min 32.1 / 31.5 41.6 / 39.0 45.9 / 43.6
exchanger

• Heating • ERLQ-CV3 7
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater No
2 Low-temperature heat pump No
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 41.0 44.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64.0 66.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 5,400
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.055
heater mode)
Poff (Off mode) kW 0.055
Psb (Standby mode) kW 0.055
Pto (Thermostat off) kW 0.057
Integrated NOx emission mg/kWh 0.00
supplementary Psup kW 9.00 3.00 9.00 3.00 9.00
heater Type of energy input Electrical
Space heating Average climate General SCOP 3.09 3.16 3.06
water outlet 55°C Annual kWh 6,260 7,900 8,970
energy
consum
ption
Annual Gj 22.6 28.4 32.3
energy
consum
ption
(GCV)
ηs % 120 123 119
(Season
al space
heating
efficienc
y)
Prated kW 9.99 12.7 13.9
at -10°C
Seasonal space A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/- COPd 1.99 1.76 1.78
8°CWB) Pdh kW 8.83 9.97 12.2
PERd % 79.6 70.4 71.2
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 3.24 3.55 3.12
1°CWB)
Pdh kW 5.28 6.76 7.61
PERd % 130 142 125

8 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate C Cdh (Degradation 0.950 1.00
3
water outlet 55°C Condition heating)
(7°CDB/ COPd 4.31 4.22 4.40
6°CWB) Pdh kW 4.47 4.66 4.83
PERd % 172 169 176
D Cdh (Degradation 0.930 0.940 0.930 2
Condition heating)
(12°CDB/ COPd 6.41 5.44 6.36
11°CWB)
Pdh kW 5.37 5.26 5.38
PERd % 256 218 254
Tol COPd 1.79 1.75 1.71
(temperat Pdh kW 9.08 12.2 13.3
ure
PERd % 71.6 70.0 68.4
operating
TOL °C -10.0
limit)
WTOL °C 55.0
Rated Psup (at kW 0.910 0.550 0.580
heat Tdesign
output -10°C)
suppleme
ntary
capacity
Tbiv COPd 1.99 1.92 1.78
(bivalent Pdh kW 8.83 11.0 12.2
temperatu PERd % 79.6 76.8 71.2
re)
Tbiv °C -7.00 -6.00 -7.00
Cold climate water General Annual kWh 6,740 7,870 8,580
outlet 55°C energy
consum
ption
Annual Gj 24.3 28.3 30.9
energy
consum
ption
(GCV)
ηs % 95.0 95.5 98.3
(Season
al space
heating
efficienc
y)
Prated kW 6.99 8.15 9.12
at -22°C
Warm climate water General Annual kWh 2,630 3,270 3,420
outlet 55°C energy
consum
ption
Annual Gj 9.47 11.8 12.3
energy
consum
ption
(GCV)
ηs % 125 135 136
(Season
al space
heating
efficienc
y)
Prated kW 7.58 9.84 10.3
at 2°C

• Heating • ERLQ-CV3 9
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.98 3.90 3.80
water outlet 35°C Annual kWh 5,380 7,250 8,270
energy
consum
ption
2 Annual Gj 19.4 26.1 29.8
energy
consum
ption
(GCV)
ηs % 156 153 149
(Season
al space
heating
efficienc
y)
Prated kW 11.2 14.5 16.0
at -10°C
Seasonal space A++ A+
heating eff. class
A COPd 2.63 2.33
Condition Pdh kW 8.88 10.7 12.4
(-7°CDB/-
PERd % 105 93.2
8°CWB)
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 4.05 4.07 3.74
1°CWB)
Pdh kW 6.03 7.71 8.62
PERd % 162 163 150
C Cdh (Degradation 0.940 1.00 0.940
Condition heating)
(7°CDB/ COPd 6.77 5.71 6.77
6°CWB)
Pdh kW 5.74 5.05 5.74
PERd % 271 228 271
D Cdh (Degradation 0.920 0.930 0.920
Condition heating)
(12°CDB/ COPd 8.97 6.71 8.97
11°CWB) Pdh kW 6.50 5.16 6.50
PERd % 359 268 359
Tol COPd 2.34 2.60 2.05
(temperat Pdh kW 8.76 12.6 11.7
ure PERd % 93.6 104 82.0
operating
TOL °C -10.0
limit)
WTOL °C 35.0
Tbiv COPd 2.82 2.83 2.56
(bivalent Pdh kW 9.09 11.6 12.1
temperatu PERd % 113 102
re)
Tbiv °C -5.00 -4.00
Rated Psup (at kW 2.44 1.93 4.35
heat Tdesign
output -10°C)
suppleme
ntary
capacity

10 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 6,430 8,170 9,050
3
outlet 35°C energy
consum
ption
ηs % 148 141 137
(Season 2
al space
heating
efficienc
y)
Prated kW 10.3 12.3 13.3
at -22°C
Qhe Gj 23.1 29.4 32.6
Annual
energy
consum
ption
(GCV)
Warm climate water General Annual kWh 1,950 2,350 2,480
outlet 35°C energy
consum
ption
Annual Gj 7.02 8.46 8.92
energy
consum
ption
(GCV)
ηs % 192 199
(Season
al space
heating
efficienc
y)
Prated kW 9.06 10.9 11.4
at 2°C
Domestic hot water Average climate ηwh (water heating % -
heating efficiency)
Cold climate ηwh (water heating % -
efficiency)
Warm climate ηwh (water heating % -
efficiency)

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(3) Tamb 35°C - LWE 7°C (DT=5°C)
(4) Tamb 35°C - LWE 18°C (DT=5°C)
(5) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(6) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
(7) Contains fluorinated greenhouse gases
(8) Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C

CONNECTABLE INDOOR UNITS


EHBX04CB3V/ EHBX08CB3V/ EHBX08CB9W/ EHBX08CB3V/ EHBX08CB9W/ EHBX11CB3V/
2-3 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ006CV3 ERLQ008CV3 ERLQ008CV3 ERLQ011CV3
Heating capacity Min. kW 1.80 (1) -
Nom. kW 4.40 (1) / 4.03 6.00 (1) / 5.67 (2) 7.40 (1) / 6.89 (2) 11.2 (1) / 11.0
(2) (2)
Max. kW 5.12 (1) / 4.90 8.35 (1) / 7.95 (2) 10.0 (1) / 9.53 (2) 8.60 (3) / 8.60
(2) (4)

• Heating • ERLQ-CV3 11
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Cooling capacity Min. kW 2.00 (1) / 2.00 2.50 (1) / 2.50 (2) -
(2)
Nom. kW 4.08 (1) / 4.17 5.88 (1) / 4.84 (2) 6.20 (1) / 5.36 (2) 12.1 (1) / 11.7
(2) (2)
Power input Heating Nom. kW 0.870 (1) / 1.27 (1) / 1.59 (2) 1.66 (1) / 2.01 (2) 2.43 (1) / 3.10
2 1.13 (2) (2)
Max. kW - 3.13 (3) / 4.10
(4)
Cooling Nom. kW 0.900 (1) / 1.51 (1) / 2.07 (2) 1.64 (1) / 2.34 (2) 3.05 (1) / 4.31
1.80 (2) (2)
COP 5.04 (1) / 3.58 4.74 (1) / 3.56 (2) 4.45 (1) / 3.42 (2) 4.60 (1) / 2.75
(2) (3) / 3.55 (2) /
2.10 (4)
EER 4.55 (1) / 2.32 3.89 (1) / 2.34 (2) 3.79 (1) / 2.29 (2) 3.98 (1) / 2.72
(2) (2)
Pump Nominal ESP unit Cooling kPa 55.0 (3) / 47.0 55.0 (3) / 39.0 (4) 50.0 (3) / 38.0 (4) 33.0 (5) / 3.00
(4) (6)
Heating kPa 53.0 (5) / 56.0 45.0 (5) / 48.0 (6) 33.0 (5) / 38.0 (6) 37.0 (7) / 39.0
(6) (8)
Water side Heat Water flow rate Cooling Nom. l/min 12.0 (3) / 14.3 13.9 (3) / 19.4 (4) 15.4 (3) / 19.7 (4) 33.6 (5) / 43.1
exchanger (4) (6)
Heating Nom. l/min 12.6 (5) / 11.6 17.2 (5) / 16.3 (6) 21.2 (5) / 19.8 (6) 32.1 (7) / 31.5
(6) (8)
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater No
Low-temperature heat pump No
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 40.0 41.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61.0 62.0 64.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 5,400
(outdoor)
Brine/water to water Rated water/brine m³/h - 0.00 - 0.00 -
unit flow
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.00 0.055
heater mode)
Poff (Off mode) kW 0.0080 0.055
Psb (Standby mode) kW 0.0080 0.055
Pto (Thermostat off) kW 0.0060 0.0070 0.0080 0.057
Integrated NOx emission mg/kWh 0.00
supplementary Psup kW 3.00 9.00 3.00 9.00 3.00
heater
Type of energy input Electrical

12 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.20 3.22 3.23 3.09
3
water outlet 55°C Annual kWh 2,356 3,369 4,064 6,260
energy
consum
ption
Annual Gj 8.48 12.1 14.6 22.6 2
energy
consum
ption
(GCV)
ηs % 125 126 120
(Season
al space
heating
efficienc
y)
Prated kW 3.70 5.30 6.40 9.99
at -10°C
Seasonal space A++ A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/- COPd 2.03 2.02 1.98 1.99
8°CWB)
Pdh kW 3.36 4.50 5.47 8.83
PERd % 81.2 80.8 79.2 79.6
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 3.08 3.17 3.24
1°CWB)
Pdh kW 2.00 4.43 3.43 5.28
PERd % 123 127 130
C Cdh (Degradation 0.990 0.950
Condition heating)
(7°CDB/ COPd 4.27 4.20 4.31
6°CWB) Pdh kW 2.77 3.51 3.50 4.47
PERd % 171 168 172
D Cdh (Degradation 0.990 0.930
Condition heating)
(12°CDB/ COPd 6.33 5.82 6.41
11°CWB)
Pdh kW 2.65 3.28 5.37
PERd % 253 233 256
Tol COPd 1.80 1.74 1.66 1.79
(temperat Pdh kW 3.76 4.62 6.18 9.08
ure
PERd % 72.0 69.6 66.4 71.6
operating
TOL °C -10.0
limit)
WTOL °C 55.0
Rated Psup (at kW 0.00 0.680 0.220 0.910
heat Tdesign
output -10°C)
suppleme
ntary
capacity
Tbiv COPd 1.80 1.74 1.66 1.99
(bivalent Pdh kW 3.76 5.09 6.18 8.83
temperatu PERd % 72.0 69.6 66.4 79.6
re)
Tbiv °C -10.0 -9.00 -10.0 -7.00

• Heating • ERLQ-CV3 13
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 2,133 2,306 3,088 6,740
outlet 55°C energy
consum
ption
Annual Gj 7.68 8.30 11.1 24.3
2 energy
consum
ption
(GCV)
ηs % 107 110 95.0
(Season
al space
heating
efficienc
y)
Prated kW 2.39 2.60 3.56 6.99
at -22°C
Warm climate water General Annual kWh 1,168 1,491 1,904 2,630
outlet 55°C energy
consum
ption
Annual Gj 4.20 5.37 6.85 9.47
energy
consum
ption
(GCV)
ηs % 186 182 178 125
(Season
al space
heating
efficienc
y)
Prated kW 4.27 5.30 6.59 7.58
at 2°C

14 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 4.52 4.29 4.34 3.98
3
water outlet 35°C Annual kWh 1,980 2,540 3,489 5,380
energy
consum
ption
Annual Gj 7.13 9.14 12.6 19.4 2
energy
consum
ption
(GCV)
ηs % 178 169 171 156
(Season
al space
heating
efficienc
y)
Prated kW 4.40 5.34 7.40 11.2
at -10°C
Seasonal space A++
heating eff. class
A COPd 3.01 2.69 2.63
Condition Pdh kW 4.01 4.72 6.68 8.88
(-7°CDB/-
PERd % 120 108 105
8°CWB)
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 4.41 4.24 4.05
1°CWB)
Pdh kW 2.40 3.90 6.03
PERd % 176 170 162
C Cdh (Degradation 0.980 1.00 0.940
Condition heating)
(7°CDB/ COPd 5.85 5.75 6.77
6°CWB)
Pdh kW 1.70 2.59 5.74
PERd % 234 230 271
D Cdh (Degradation 0.980 0.920
Condition heating)
(12°CDB/ COPd 7.71 7.27 8.97
11°CWB) Pdh kW 39.2 2.61 6.50
PERd % 308 291 359
Tol COPd 2.61 2.29 2.34
(temperat Pdh kW 4.36 4.70 6.81 8.76
ure PERd % 104 91.6 93.6
operating
TOL °C -10.0
limit)
WTOL °C 35.0
G COPd 0.00 -
Condition Pdh kW 0.00 -
(- PERd % 0.00 -
15°CDB/-
)
Tbiv COPd 2.61 2.47 2.82
(bivalent Pdh kW 4.36 4.93 7.14 9.09
temperatu
PERd % 104 98.8 113
re)
Tbiv °C -10.0 -8.00 -5.00
Rated Psup (at kW 0.040 0.640 0.590 2.44
heat Tdesign
output -10°C)
suppleme
ntary
capacity

• Heating • ERLQ-CV3 15
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 1,450 2,040 2,480 6,430
outlet 35°C energy
consum
ption
ηs % 151 153 151 148
2 (Season
al space
heating
efficienc
y)
Prated kW 2.28 3.25 3.89 10.3
at -22°C
Qhe Gj 5.20 7.34 8.91 23.1
Annual
energy
consum
ption
(GCV)
Warm climate water General Annual kWh 905 1,270 1,570 1,950
outlet 35°C energy
consum
ption
Annual Gj 3.26 4.56 5.67 7.02
energy
consum
ption
(GCV)
ηs % 269 259 251 192
(Season
al space
heating
efficienc
y)
Prated kW 4.81 6.40 7.68 9.06
at 2°C
Domestic hot water General Function to fix water heating Yes -
heating during off peak hours
Average climate ηwh (water heating % -
efficiency)
Cold climate ηwh (water heating % -
efficiency)
Warm climate ηwh (water heating % -
efficiency)

CONNECTABLE INDOOR UNITS


EHBX11CB9W/ EHBX16CB3V/ EHBX16CB9W/ EHBX16CB9W/ EHBX16CB3V/
2-4 Capacity and Power input ERLQ011CV3 ERLQ014CV3 ERLQ014CV3 ERLQ016CV3 ERLQ016CV3
Heating capacity Nom. kW 11.2 / 11.0 14.5 / 13.6 16.0 / 15.2
Max. kW 8.60 / 8.60 10.6 / 10.8 11.4 / 10.9
Cooling capacity Nom. kW 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1
Power input Heating Nom. kW 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66
Max. kW 3.13 / 4.10 4.00 / 5.19 4.32 / 5.22
Cooling Nom. kW 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73
COP 4.60 / 2.75 / 3.55 / 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09
2.10
EER 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29
Pump Nominal ESP unit Cooling kPa 33.0 / 3.00 64.0 / 32.0 61.0 / 23.0
Heating kPa 37.0 / 39.0 49.0 / 57.0 33.0 / 42.0
Water side Heat Water flow rate Cooling Nom. l/min 33.6 / 43.1 36.0 / 46.0 37.6 / 48.0
exchanger Heating Nom. l/min 32.1 / 31.5 41.6 / 39.0 45.9 / 43.6

16 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
3
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater No
Low-temperature heat pump No
2
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 41.0 44.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64.0 66.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 5,400
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.055
heater mode)
Poff (Off mode) kW 0.055
Psb (Standby mode) kW 0.055
Pto (Thermostat off) kW 0.057
Integrated NOx emission mg/ 0.00
supplementary kWh
heater Psup kW 9.00 3.00 9.00 3.00
Type of energy input Electrical
Space heating Average climate General SCOP 3.09 3.16 3.06
water outlet 55°C Annual kWh 6,260 7,900 8,970
energy
consumpt
ion
Annual Gj 22.6 28.4 32.3
energy
consumpt
ion
(GCV)
ηs % 120 123 119
(Seasona
l space
heating
efficiency
)
Prated at kW 9.99 12.7 13.9
-10°C
Seasonal space A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/- COPd 1.99 1.76 1.78
8°CWB)
Pdh kW 8.83 9.97 12.2
PERd % 79.6 70.4 71.2
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 3.24 3.55 3.12
1°CWB)
Pdh kW 5.28 6.76 7.61
PERd % 130 142 125

• Heating • ERLQ-CV3 17
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate C Cdh (Degradation 0.950 1.00
water outlet 55°C Condition heating)
(7°CDB/ COPd 4.31 4.22 4.40
6°CWB) Pdh kW 4.47 4.66 4.83
PERd % 172 169 176
2 D Cdh (Degradation 0.930 0.940 0.930
Condition heating)
(12°CDB/ COPd 6.41 5.44 6.36
11°CWB)
Pdh kW 5.37 5.26 5.38
PERd % 256 218 254
Tol COPd 1.79 1.75 1.71
(temperat Pdh kW 9.08 12.2 13.3
ure
PERd % 71.6 70.0 68.4
operating
TOL °C -10.0
limit)
WTOL °C 55.0
Rated Psup (at kW 0.910 0.550 0.580
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 1.99 1.92 1.78
(bivalent Pdh kW 8.83 11.0 12.2
temperatu PERd % 79.6 76.8 71.2
re)
Tbiv °C -7.00 -6.00 -7.00
Cold climate water General Annual kWh 6,740 7,870 8,580
outlet 55°C energy
consumpt
ion
Annual Gj 24.3 28.3 30.9
energy
consumpt
ion
(GCV)
ηs % 95.0 95.5 98.3
(Seasona
l space
heating
efficiency
)
Prated at kW 6.99 8.15 9.12
-22°C
Warm climate water General Annual kWh 2,630 3,270 3,420
outlet 55°C energy
consumpt
ion
Annual Gj 9.47 11.8 12.3
energy
consumpt
ion
(GCV)
ηs % 125 135 136
(Seasona
l space
heating
efficiency
)
Prated at kW 7.58 9.84 10.3
2°C

18 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.98 3.90 3.80
3
water outlet 35°C Annual kWh 5,380 7,250 8,270
energy
consumpt
ion
Annual Gj 19.4 26.1 29.8 2
energy
consumpt
ion
(GCV)
ηs % 156 153 149
(Seasona
l space
heating
efficiency
)
Prated at kW 11.2 14.5 16.0
-10°C
Seasonal space A++ A+
heating eff. class
A COPd 2.63 2.33
Condition Pdh kW 8.88 10.7 12.4
(-7°CDB/-
PERd % 105 93.2
8°CWB)
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 4.05 4.07 3.74
1°CWB)
Pdh kW 6.03 7.71 8.62
PERd % 162 163 150
C Cdh (Degradation 0.940 1.00 0.940
Condition heating)
(7°CDB/ COPd 6.77 5.71 6.77
6°CWB)
Pdh kW 5.74 5.05 5.74
PERd % 271 228 271
D Cdh (Degradation 0.920 0.930 0.920
Condition heating)
(12°CDB/ COPd 8.97 6.71 8.97
11°CWB) Pdh kW 6.50 5.16 6.50
PERd % 359 268 359
Tol COPd 2.34 2.60 2.05
(temperat Pdh kW 8.76 12.6 11.7
ure PERd % 93.6 104 82.0
operating
TOL °C -10.0
limit)
WTOL °C 35.0
Tbiv COPd 2.82 2.83 2.56
(bivalent Pdh kW 9.09 11.6 12.1
temperatu PERd % 113 102
re)
Tbiv °C -5.00 -4.00
Rated Psup (at kW 2.44 1.93 4.35
heat Tdesign -
output 10°C)
suppleme
ntary
capacity

• Heating • ERLQ-CV3 19
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Cold climate water General Annual kWh 6,430 8,170 9,050
outlet 35°C energy
consumpt
ion
ηs % 148 141 137
2 (Seasona
l space
heating
efficiency
)
Prated at kW 10.3 12.3 13.3
-22°C
Qhe Gj 23.1 29.4 32.6
Annual
energy
consumpt
ion
(GCV)
Warm climate water General Annual kWh 1,950 2,350 2,480
outlet 35°C energy
consumpt
ion
Annual Gj 7.02 8.46 8.92
energy
consumpt
ion
(GCV)
ηs % 192 199
(Seasona
l space
heating
efficiency
)
Prated at kW 9.06 10.9 11.4
2°C
Domestic hot water Average climate ηwh (water heating % -
heating efficiency)
Cold climate ηwh (water heating % -
efficiency)
Warm climate ηwh (water heating % -
efficiency)

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(3) Tamb 35°C - LWE 7°C (DT=5°C)
(4) Tamb 35°C - LWE 18°C (DT=5°C)
(5) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(6) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
(7) Contains fluorinated greenhouse gases
(8) Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C

CONNECTABLE INDOOR UNITS


EHVH04S18CB EHVH08S26CB EHVH08S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB
3V/ 9W/ 3V/ 3V/ 9W/ 3V/
2-5 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ006CV3 ERLQ008CV3 ERLQ008CV3 ERLQ011CV3
Heating capacity Min. kW 1.80 (1) -
Nom. kW 4.40 (1) / 4.03 6.00 (1) / 5.67 (2) 7.40 (1) / 6.89 (2) 11.2 (1) / 11.0
(2) (2)
Max. kW 5.12 (1) / 4.90 8.35 (1) / 7.95 (2) 10.0 (1) / 9.53 (2) 8.60 (3) / 8.60
(2) (4)

20 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Power input Heating Nom. kW 0.870 (1) / 1.27 (1) / 1.59 (2) 1.66 (1) / 2.01 (2) 2.43 (1) / 3.10
3
1.13 (2) (2)
Max. kW - 3.13 (3) / 4.10
(4)
COP 5.04 (1) / 3.58 4.74 (1) / 3.56 (2) 4.45 (1) / 3.42 (2) 4.60 (1) / 2.75
(2) (3) / 3.55 (2) / 2
2.10 (4)
Tank Name Stainless steel - Stainless steel
domestic hot domestic hot
water tank 180 water tank 180
l l
Pump Nominal ESP unit Heating kPa 53.0 (5) / 56.0 45.0 (5) / 47.0 (6) 33.0 (5) / 37.0 (6) 34.2 (7) / 35.9
(6) (8)
Water side Heat Water flow rate Heating Nom. l/min 12.6 (5) / 11.6 17.2 (5) / 16.3 (6) 21.2 (5) / 19.8 (6) 32.1 (7) / 31.5
exchanger (6) (8)
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 42.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61.0 62.0 64.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 5,400
(outdoor)
Brine/water to water Rated water/brine m³/h - 0.00 -
unit flow
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.00 0.055
heater mode)
Poff (Off mode) kW 0.0080 0.055
Psb (Standby mode) kW 0.0080 0.055
Pto (Thermostat off) kW 0.0060 0.0070 0.0080 0.057
Integrated NOx emission mg/kWh 0.00
supplementary Psup kW 3.00 9.00 3.00
heater
Type of energy input Electrical

• Heating • ERLQ-CV3 21
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.20 3.22 3.23 3.09
water outlet 55°C Annual kWh 2,356 3,369 4,064 6,260
energy
consum
ption
2 Annual Gj 8.48 12.1 14.6 22.6
energy
consum
ption
(GCV)
ηs % 125 126 120
(Seaso
nal
space
heating
efficienc
y)
Prated kW 3.70 5.30 6.40 9.99
at -10°C
Seasonal space A++ A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/- COPd 2.03 2.02 1.98 1.99
8°CWB) Pdh kW 3.36 4.50 5.47 8.83
PERd % 81.2 80.8 79.2 79.6
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 3.08 3.17 3.24
1°CWB) Pdh kW 2.00 4.43 3.43 5.28
PERd % 123 127 130
C Cdh (Degradation 0.990 0.950
Condition heating)
(7°CDB/ COPd 4.27 4.20 4.31
6°CWB)
Pdh kW 2.77 3.51 3.50 4.47
PERd % 171 168 172
D Cdh (Degradation 0.990 0.930
Condition heating)
(12°CDB/ COPd 6.33 5.82 6.41
11°CWB)
Pdh kW 2.65 3.28 5.37
PERd % 253 233 256
Tol COPd 1.80 1.74 1.66 1.79
(temperat Pdh kW 3.76 4.62 6.18 9.08
ure
PERd % 72.0 69.6 66.4 71.6
operating
limit) TOL °C -10.0
WTOL °C 55.0
Rated Psup (at kW 0.00 0.680 0.220 0.910
heat Tdesign
output -10°C)
suppleme
ntary
capacity
Tbiv COPd 1.80 1.74 1.66 1.99
(bivalent Pdh kW 3.76 5.09 6.18 8.83
temperat
PERd % 72.0 69.6 66.4 79.6
ure)
Tbiv °C -10.0 -9.00 -10.0 -7.00

22 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 2,133 2,306 3,088 6,740
3
outlet 55°C energy
consum
ption
Annual Gj 7.68 8.30 11.1 24.3
energy 2
consum
ption
(GCV)
ηs % 107 110 95.0
(Seaso
nal
space
heating
efficienc
y)
Prated kW 2.39 2.60 3.56 6.99
at -22°C
Warm climate water General Annual kWh 1,168 1,491 1,904 2,630
outlet 55°C energy
consum
ption
Annual Gj 4.20 5.37 6.85 9.47
energy
consum
ption
(GCV)
ηs % 186 182 178 125
(Seaso
nal
space
heating
efficienc
y)
Prated kW 4.27 5.30 6.59 7.58
at 2°C

• Heating • ERLQ-CV3 23
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 4.52 4.29 4.34 3.98
water outlet 35°C Annual kWh 1,980 2,540 3,489 5,380
energy
consum
ption
2 Annual Gj 7.13 9.14 12.6 19.4
energy
consum
ption
(GCV)
ηs % 178 169 171 156
(Seaso
nal
space
heating
efficienc
y)
Prated kW 4.40 5.34 7.40 11.2
at -10°C
Seasonal space A++
heating eff. class
A COPd 3.01 2.69 2.63
Condition Pdh kW 4.01 4.72 6.68 8.88
(-7°CDB/-
PERd % 120 108 105
8°CWB)
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 4.41 4.24 4.05
1°CWB)
Pdh kW 2.40 3.90 6.03
PERd % 176 170 162
C Cdh (Degradation 0.980 1.00 0.940
Condition heating)
(7°CDB/ COPd 5.85 5.75 6.77
6°CWB) Pdh kW 1.70 2.59 5.74
PERd % 234 230 271
D Cdh (Degradation 0.980 0.920
Condition heating)
(12°CDB/ COPd 7.71 7.27 8.97
11°CWB)
Pdh kW 39.2 2.61 6.50
PERd % 308 291 359
Tol COPd 2.61 2.29 2.34
(temperat Pdh kW 4.36 4.70 6.81 8.76
ure
PERd % 104 91.6 93.6
operating
TOL °C -10.0
limit)
WTOL °C 35.0
G COPd 0.00 -
Condition Pdh kW 0.00 -
(-
PERd % 0.00 -
15°CDB/-
)
Tbiv COPd 2.61 2.47 2.82
(bivalent Pdh kW 4.36 4.93 7.14 9.09
temperat
PERd % 104 98.8 113
ure)
Tbiv °C -10.0 -8.00 -5.00
Rated Psup (at kW 0.040 0.640 0.590 2.44
heat Tdesign
output -10°C)
suppleme
ntary
capacity

24 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh - 6,430
3
outlet 35°C energy
consum
ption
ηs % - 148
(Seaso 2
nal
space
heating
efficienc
y)
Prated kW - 10.3
at -22°C
Qhe Gj - 23.1
Annual
energy
consum
ption
(GCV)
Warm climate water General Annual kWh - 1,950
outlet 35°C energy
consum
ption
Annual Gj - 7.02
energy
consum
ption
(GCV)
ηs % - 192
(Seaso
nal
space
heating
efficienc
y)
Prated kW - 9.06
at 2°C

• Heating • ERLQ-CV3 25
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile L XL L XL L
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,084 1,871 1,194 1,871 1,170
electricity
2 consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 95.0 90.0 86.4 90.0 87.4
efficiency)
Qelec (Daily kWh 4.93 8.50 5.43 8.50 5.32
electricity
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,221 2,037 1,332 2,037 1,340
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 84.0 83.0 77.5 83.0 76.6
efficiency)
Qelec (Daily kWh 5.55 9.26 6.05 9.26 6.08
electricity
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Warm climate AEC (Annual kWh 966 1,784 1,123 1,784 1,110
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 106 94.0 91.8 94.0 92.3
efficiency)
Qelec (Daily kWh 4.39 8.11 5.10 8.11 5.04
electricity
consumption)
Qfuel (Daily fuel kWh - 0.00
consumption)

CONNECTABLE INDOOR UNITS


EHVH11S26CB9W/ EHVH16S18CB3V/ EHVH16S26CB9W/ EHVH16S18CB3V/ EHVH16S26CB9W/
2-6 Capacity and Power input ERLQ011CV3 ERLQ014CV3 ERLQ014CV3 ERLQ016CV3 ERLQ016CV3
Heating capacity Nom. kW 11.2 / 11.0 14.5 / 13.6 16.0 / 15.2
Max. kW 8.60 / 8.60 10.6 / 10.8 11.4 / 10.9
Power input Heating Nom. kW 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66
Max. kW 3.13 / 4.10 4.00 / 5.19 4.32 / 5.22
COP 4.60 / 2.75 / 3.55 / 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09
2.10
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 260 l water tank 180 l water tank 260 l water tank 180 l water tank 260 l
Pump Nominal ESP unit Heating kPa 34.2 / 35.9 43.2 / 51.2 26.8 / 36.3
Water side Heat Water flow rate Heating Nom. l/min 32.1 / 31.5 41.6 / 39.0 45.9 / 43.6
exchanger

26 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
3
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
2
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 42.0 44.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64.0 66.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 5,400
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.055
heater mode)
Poff (Off mode) kW 0.055
Psb (Standby mode) kW 0.055
Pto (Thermostat off) kW 0.057
Integrated NOx emission mg/kWh 0.00
supplementary Psup kW 9.00 3.00 9.00 3.00 9.00
heater
Type of energy input Electrical
Space heating Average climate General SCOP 3.09 3.16 3.06
water outlet 55°C Annual kWh 6,260 7,900 8,970
energy
consumpt
ion
Annual Gj 22.6 28.4 32.3
energy
consumpt
ion (GCV)
ηs % 120 123 119
(Seasonal
space
heating
efficiency)
Prated at kW 9.99 12.7 13.9
-10°C
Seasonal space A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/- COPd 1.99 1.76 1.78
8°CWB) Pdh kW 8.83 9.97 12.2
PERd % 79.6 70.4 71.2
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 3.24 3.55 3.12
1°CWB)
Pdh kW 5.28 6.76 7.61
PERd % 130 142 125
C Cdh (Degradation 0.950 1.00
Condition heating)
(7°CDB/ COPd 4.31 4.22 4.40
6°CWB)
Pdh kW 4.47 4.66 4.83
PERd % 172 169 176

• Heating • ERLQ-CV3 27
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate D Cdh (Degradation 0.930 0.940 0.930
water outlet 55°C Condition heating)
(12°CDB/ COPd 6.41 5.44 6.36
11°CWB) Pdh kW 5.37 5.26 5.38
PERd % 256 218 254
2 Tol COPd 1.79 1.75 1.71
(temperat Pdh kW 9.08 12.2 13.3
ure PERd % 71.6 70.0 68.4
operating
TOL °C -10.0
limit)
WTOL °C 55.0
Rated Psup (at kW 0.910 0.550 0.580
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 1.99 1.92 1.78
(bivalent Pdh kW 8.83 11.0 12.2
temperatu
PERd % 79.6 76.8 71.2
re)
Tbiv °C -7.00 -6.00 -7.00
Cold climate water General Annual kWh 6,740 7,870 8,580
outlet 55°C energy
consumpt
ion
Annual Gj 24.3 28.3 30.9
energy
consumpt
ion (GCV)
ηs % 95.0 95.5 98.3
(Seasonal
space
heating
efficiency)
Prated at kW 6.99 8.15 9.12
-22°C
Warm climate water General Annual kWh 2,630 3,270 3,420
outlet 55°C energy
consumpt
ion
Annual Gj 9.47 11.8 12.3
energy
consumpt
ion (GCV)
ηs % 125 135 136
(Seasonal
space
heating
efficiency)
Prated at kW 7.58 9.84 10.3
2°C

28 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.98 3.90 3.80
3
water outlet 35°C Annual kWh 5,380 7,250 8,270
energy
consumpt
ion
Annual Gj 19.4 26.1 29.8 2
energy
consumpt
ion (GCV)
ηs % 156 153 149
(Seasonal
space
heating
efficiency)
Prated at kW 11.2 14.5 16.0
-10°C
Seasonal space A++ A+
heating eff. class
A COPd 2.63 2.33
Condition Pdh kW 8.88 10.7 12.4
(-7°CDB/-
PERd % 105 93.2
8°CWB)
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 4.05 4.07 3.74
1°CWB) Pdh kW 6.03 7.71 8.62
PERd % 162 163 150
C Cdh (Degradation 0.940 1.00 0.940
Condition heating)
(7°CDB/ COPd 6.77 5.71 6.77
6°CWB) Pdh kW 5.74 5.05 5.74
PERd % 271 228 271
D Cdh (Degradation 0.920 0.930 0.920
Condition heating)
(12°CDB/ COPd 8.97 6.71 8.97
11°CWB)
Pdh kW 6.50 5.16 6.50
PERd % 359 268 359
Tol COPd 2.34 2.60 2.05
(temperat Pdh kW 8.76 12.6 11.7
ure
PERd % 93.6 104 82.0
operating
TOL °C -10.0
limit)
WTOL °C 35.0
Tbiv COPd 2.82 2.83 2.56
(bivalent Pdh kW 9.09 11.6 12.1
temperatu
PERd % 113 102
re)
Tbiv °C -5.00 -4.00
Rated Psup (at kW 2.44 1.93 4.35
heat Tdesign -
output 10°C)
suppleme
ntary
capacity

• Heating • ERLQ-CV3 29
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 6,430 8,170 9,050
outlet 35°C energy
consumpt
ion
ηs % 148 141 137
2 (Seasonal
space
heating
efficiency)
Prated at kW 10.3 12.3 13.3
-22°C
Qhe Gj 23.1 29.4 32.6
Annual
energy
consumpt
ion (GCV)
Warm climate water General Annual kWh 1,950 2,350 2,480
outlet 35°C energy
consumpt
ion
Annual Gj 7.02 8.46 8.92
energy
consumpt
ion (GCV)
ηs % 192 199
(Seasonal
space
heating
efficiency)
Prated at kW 9.06 10.9 11.4
2°C

30 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile XL L XL L XL
3
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,720 1,170 1,720 1,170 1,720
electricity
consumption) 2
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 97.7 87.4 97.7 87.4 97.7
efficiency)
Qelec (Daily electricity kWh 7.83 5.32 7.83 5.32 7.83
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,980 1,340 1,980 1,340 1,980
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 85.1 76.6 85.1 76.6 85.1
efficiency)
Qelec (Daily electricity kWh 8.99 6.08 8.99 6.08 8.99
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Warm climate AEC (Annual kWh 1,630 1,110 1,630 1,110 1,630
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 103 92.3 103 92.3 103
efficiency)
Qelec (Daily electricity kWh 7.40 5.04 7.40 5.04 7.40
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(3) Tamb 35°C - LWE 7°C (DT=5°C)
(4) Tamb 35°C - LWE 18°C (DT=5°C)
(5) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(6) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
(7) Contains fluorinated greenhouse gases
(8) Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C

CONNECTABLE INDOOR UNITS


2-7 Capacity and Power input EHVH04S18CB3VF/ERLQ004CV3 EHVH08S18CB3VF/ERLQ006CV3 EHVH08S18CB3VF/ERLQ008CV3
Heating capacity Min. kW 1.80 (1)
Nom. kW 4.40 (1) / 4.03 (2) 6.00 (1) / 5.67 (2) 7.40 (1) / 6.89 (2)
Max. kW 5.12 (1) / 4.90 (2) 8.35 (1) / 7.95 (2) 10.0 (1) / 9.53 (2)
Power input Heating Nom. kW 0.870 (1) / 1.13 (2) 1.27 (1) / 1.59 (2) 1.66 (1) / 2.01 (2)
COP 5.04 (1) / 3.58 (2) 4.74 (1) / 3.56 (2) 4.45 (1) / 3.42 (2)
Tank Name Stainless steel domestic hot -
water tank 180 l

• Heating • ERLQ-CV3 31
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Pump Nominal ESP unit Heating kPa 53.0 (3) / 56.0 (4) 45.0 (3) / 47.0 (4) 33.0 (3) / 37.0 (4)
Water side Heat Water flow rate Heating Nom. l/min 12.6 (3) / 11.6 (4) 17.2 (3) / 16.3 (4) 21.2 (3) / 19.8 (4)
exchanger
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer details Name or trademark Daikin Europe N.V.
2 Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 42.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61.0 62.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820
(outdoor)
Brine/water to water Rated water/brine flow m³/h - 0.00
unit
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.00
heater mode)
Poff (Off mode) kW 0.0080
Psb (Standby mode) kW 0.0080
Pto (Thermostat off) kW 0.0060 0.0070 0.0080
Integrated NOx emission mg/ 0.00
supplementary kWh
heater Psup kW 3.00
Type of energy input Electrical

32 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.20 3.22 3.23
3
water outlet 55°C Annual kWh 2,356 3,369 4,064
energy
consumpti
on
Annual Gj 8.48 12.1 14.6 2
energy
consumpti
on (GCV)
ηs % 125 126
(Seasonal
space
heating
efficiency)
Prated at - kW 3.70 5.30 6.40
10°C
Seasonal space A++
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/ COPd 2.03 2.02 1.98
-8°CWB) Pdh kW 3.36 4.50 5.47
PERd % 81.2 80.8 79.2
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 3.08 3.17
1°CWB) Pdh kW 2.00 4.43 3.43
PERd % 123 127
C Cdh (Degradation 0.990
Condition heating)
(7°CDB/ COPd 4.27 4.20
6°CWB)
Pdh kW 2.77 3.51 3.50
PERd % 171 168
D Cdh (Degradation 0.990
Condition heating)
(12°CDB/ COPd 6.33 5.82
11°CWB)
Pdh kW 2.65 3.28
PERd % 253 233
Tol COPd 1.80 1.74 1.66
(temperat Pdh kW 3.76 4.62 6.18
ure
PERd % 72.0 69.6 66.4
operating
limit) TOL °C -10.0
WTOL °C 55.0
Rated Psup (at kW 0.00 0.680 0.220
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 1.80 1.74 1.66
(bivalent Pdh kW 3.76 5.09 6.18
temperat
PERd % 72.0 69.6 66.4
ure)
Tbiv °C -10.0 -9.00 -10.0

• Heating • ERLQ-CV3 33
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 2,133 2,306 3,088
outlet 55°C energy
consumpti
on
Annual Gj 7.68 8.30 11.1
2 energy
consumpti
on (GCV)
ηs % 107 110
(Seasonal
space
heating
efficiency)
Prated at - kW 2.39 2.60 3.56
22°C
Warm climate water General Annual kWh 1,168 1,491 1,904
outlet 55°C energy
consumpti
on
Annual Gj 4.20 5.37 6.85
energy
consumpti
on (GCV)
ηs % 186 182 178
(Seasonal
space
heating
efficiency)
Prated at kW 4.27 5.30 6.59
2°C

34 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 4.52 4.29 4.34
3
water outlet 35°C Annual kWh 1,980 2,540 3,489
energy
consumpti
on
Annual Gj 7.13 9.14 12.6 2
energy
consumpti
on (GCV)
ηs % 178 169 171
(Seasonal
space
heating
efficiency)
Prated at - kW 4.40 5.34 7.40
10°C
Seasonal space A++
heating eff. class
A COPd 3.01 2.69
Condition Pdh kW 4.01 4.72 6.68
(-7°CDB/
PERd % 120 108
-8°CWB)
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 4.41 4.24
1°CWB) Pdh kW 2.40 3.90
PERd % 176 170
C Cdh (Degradation 0.980 1.00
Condition heating)
(7°CDB/ COPd 5.85 5.75
6°CWB) Pdh kW 1.70 2.59
PERd % 234 230
D Cdh (Degradation 0.980
Condition heating)
(12°CDB/ COPd 7.71 7.27
11°CWB)
Pdh kW 39.2 2.61
PERd % 308 291
Tol COPd 2.61 2.29
(temperat Pdh kW 4.36 4.70 6.81
ure
PERd % 104 91.6
operating
TOL °C -10.0
limit)
WTOL °C 35.0
G COPd 0.00
Condition Pdh kW 0.00
(-
PERd % 0.00
15°CDB/-
)
Tbiv COPd 2.61 2.47
(bivalent Pdh kW 4.36 4.93 7.14
temperat
PERd % 104 98.8
ure)
Tbiv °C -10.0 -8.00
Rated Psup (at kW 0.040 0.640 0.590
heat Tdesign -
output 10°C)
suppleme
ntary
capacity

• Heating • ERLQ-CV3 35
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
2 Qhe Gj -
Annual
energy
consumpti
on (GCV)
Warm climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
Domestic hot water General Declared load profile L
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,084 1,194
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 95.0 86.4
efficiency)
Qelec (Daily electricity kWh 4.93 5.43
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,221 1,332
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 84.0 77.5
efficiency)
Qelec (Daily electricity kWh 5.55 6.05
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Warm climate AEC (Annual kWh 966 1,123
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 106 91.8
efficiency)
Qelec (Daily electricity kWh 4.39 5.10
consumption)

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(3) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(4) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
Tamb 35°C - LWE 7°C (DT=5°C)
Tamb 35°C - LWE 18°C (DT=5°C)
Contains fluorinated greenhouse gases

36 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


EHVX04S18CB EHVX08S18CB EHVX08S26CB EHVX08S18CB EHVX08S26CB EHVX11S18CB
3
3V/ 3V/ 9W/ 3V/ 9W/ 3V/
2-8 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ006CV3 ERLQ008CV3 ERLQ008CV3 ERLQ011CV3
Heating capacity Min. kW 1.80 (1) -
Nom. kW 4.40 (1) / 4.03 6.00 (1) / 5.67 (2) 7.40 (1) / 6.89 (2) 11.2 (1) / 11.0
(2) (2) 2
Max. kW 5.12 (1) / 4.90 8.35 (1) / 7.95 (2) 10.0 (1) / 9.53 (2) 8.60 (3) / 8.60
(2) (4)
Cooling capacity Min. kW 2.00 (1) / 2.00 2.50 (1) / 2.50 (2) -
(2)
Nom. kW 4.08 (1) / 4.17 5.88 (1) / 4.84 (2) 6.20 (1) / 5.36 (2) 12.1 (1) / 11.7
(2) (2)
Power input Heating Nom. kW 0.870 (1) / 1.27 (1) / 1.59 (2) 1.66 (1) / 2.01 (2) 2.43 (1) / 3.10
1.13 (2) (2)
Max. kW - 3.13 (3) / 4.10
(4)
Cooling Nom. kW 0.900 (1) / 1.51 (1) / 2.07 (2) 1.64 (1) / 2.34 (2) 3.05 (1) / 4.31
1.80 (2) (2)
COP 5.04 (1) / 3.58 4.74 (1) / 3.56 (2) 4.45 (1) / 3.42 (2) 4.60 (1) / 2.75
(2) (3) / 3.55 (2) /
2.10 (4)
EER 4.55 (1) / 2.32 3.89 (1) / 2.34 (2) 3.79 (1) / 2.29 (2) 3.98 (1) / 2.72
(2) (2)
Tank Name - Stainless steel
domestic hot
water tank 180
l
Pump Nominal ESP unit Cooling kPa 54.0 (3) / 47.0 54.0 (3) / 38.0 (4) 50.0 (3) / 37.0 (4) 29.8 (5) / 1.30
(4) (6)
Heating kPa 53.0 (5) / 56.0 45.0 (5) / 47.0 (6) 33.0 (5) / 37.0 (6) 34.2 (7) / 35.9
(6) (8)
Water side Heat Water flow rate Cooling Nom. l/min 12.0 (3) / 14.3 13.9 (3) / 19.4 (4) 15.4 (3) / 19.7 (4) 33.6 (5) / 43.1
exchanger (4) (6)
Heating Nom. l/min 12.6 (5) / 11.6 17.2 (5) / 16.3 (6) 21.2 (5) / 19.8 (6) 32.1 (7) / 31.5
(6) (8)
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 42.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61.0 62.0 64.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825

• Heating • ERLQ-CV3 37
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 5,400
(outdoor)
Brine/water to water Rated water/brine m³/h - 0.00 -
unit flow
Other Capacity control Inverter
2 Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.00 0.055
heater mode)
Poff (Off mode) kW 0.0080 0.055
Psb (Standby mode) kW 0.0080 0.055
Pto (Thermostat off) kW 0.0060 0.0070 0.0080 0.057
Integrated NOx emission mg/ 0.00
supplementary kWh
heater Psup kW 3.00 9.00 3.00 9.00 3.00
Type of energy input Electrical
Space heating Average climate General SCOP 3.20 3.22 3.23 3.09
water outlet 55°C Annual kWh 2,356 3,369 4,064 6,260
energy
consum
ption
Annual Gj 8.48 12.1 14.6 22.6
energy
consum
ption
(GCV)
ηs % 125 126 120
(Season
al space
heating
efficienc
y)
Prated at kW 3.70 5.30 6.40 9.99
-10°C
Seasonal space A++ A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/- COPd 2.03 2.02 1.98 1.99
8°CWB)
Pdh kW 3.36 4.50 5.47 8.83
PERd % 81.2 80.8 79.2 79.6
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 3.08 3.17 3.24
1°CWB) Pdh kW 2.00 4.43 3.43 5.28
PERd % 123 127 130
C Cdh (Degradation 0.990 0.950
Condition heating)
(7°CDB/ COPd 4.27 4.20 4.31
6°CWB)
Pdh kW 2.77 3.51 3.50 4.47
PERd % 171 168 172
D Cdh (Degradation 0.990 0.930
Condition heating)
(12°CDB/ COPd 6.33 5.82 6.41
11°CWB)
Pdh kW 2.65 3.28 5.37
PERd % 253 233 256
Tol COPd 1.80 1.74 1.66 1.79
(temperatu Pdh kW 3.76 4.62 6.18 9.08
re
PERd % 72.0 69.6 66.4 71.6
operating
limit) TOL °C -10.0
WTOL °C 55.0

38 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate Rated heat Psup (at kW 0.00 0.680 0.220 0.910
3
water outlet 55°C output Tdesign
suppleme -10°C)
ntary
capacity
Tbiv COPd 1.80 1.74 1.66 1.99 2
(bivalent Pdh kW 3.76 5.09 6.18 8.83
temperatur PERd % 72.0 69.6 66.4 79.6
e)
Tbiv °C -10.0 -9.00 -10.0 -7.00
Cold climate water General Annual kWh 2,133 2,306 3,088 6,740
outlet 55°C energy
consum
ption
Annual Gj 7.68 8.30 11.1 24.3
energy
consum
ption
(GCV)
ηs % 107 110 95.0
(Season
al space
heating
efficienc
y)
Prated at kW 2.39 2.60 3.56 6.99
-22°C
Warm climate water General Annual kWh 1,168 1,491 1,904 2,630
outlet 55°C energy
consum
ption
Annual Gj 4.20 5.37 6.85 9.47
energy
consum
ption
(GCV)
ηs % 186 182 178 125
(Season
al space
heating
efficienc
y)
Prated at kW 4.27 5.30 6.59 7.58
2°C

• Heating • ERLQ-CV3 39
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 4.52 4.29 4.34 3.98
water outlet 35°C Annual kWh 1,980 2,540 3,489 5,380
energy
consum
ption
2 Annual Gj 7.13 9.14 12.6 19.4
energy
consum
ption
(GCV)
ηs % 178 169 171 156
(Season
al space
heating
efficienc
y)
Prated at kW 4.40 5.34 7.40 11.2
-10°C
Seasonal space A++
heating eff. class
A COPd 3.01 2.69 2.63
Condition Pdh kW 4.01 4.72 6.68 8.88
(-7°CDB/-
PERd % 120 108 105
8°CWB)
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 4.41 4.24 4.05
1°CWB)
Pdh kW 2.40 3.90 6.03
PERd % 176 170 162
C Cdh (Degradation 0.980 1.00 0.940
Condition heating)
(7°CDB/ COPd 5.85 5.75 6.77
6°CWB)
Pdh kW 1.70 2.59 5.74
PERd % 234 230 271
D Cdh (Degradation 0.980 0.920
Condition heating)
(12°CDB/ COPd 7.71 7.27 8.97
11°CWB) Pdh kW 39.2 2.61 6.50
PERd % 308 291 359
Tol COPd 2.61 2.29 2.34
(temperatu Pdh kW 4.36 4.70 6.81 8.76
re PERd % 104 91.6 93.6
operating
TOL °C -10.0
limit)
WTOL °C 35.0
G COPd 0.00 -
Condition Pdh kW 0.00 -
(-15°CDB/ PERd % 0.00 -
-)
Tbiv COPd 2.61 2.47 2.82
(bivalent Pdh kW 4.36 4.93 7.14 9.09
temperatur PERd % 104 98.8 113
e)
Tbiv °C -10.0 -8.00 -5.00
Rated heat Psup (at kW 0.040 0.640 0.590 2.44
output Tdesign
suppleme -10°C)
ntary
capacity

40 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh - 6,430
3
outlet 35°C energy
consum
ption
ηs % - 148
(Season 2
al space
heating
efficienc
y)
Prated at kW - 10.3
-22°C
Qhe Gj - 23.1
Annual
energy
consum
ption
(GCV)
Warm climate water General Annual kWh - 1,950
outlet 35°C energy
consum
ption
Annual Gj - 7.02
energy
consum
ption
(GCV)
ηs % - 192
(Season
al space
heating
efficienc
y)
Prated at kW - 9.06
2°C

• Heating • ERLQ-CV3 41
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile L XL L XL L
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,084 1,194 1,871 1,194 1,871 1,170
electricity
2 consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 95.0 86.4 90.0 86.4 90.0 87.4
efficiency)
Qelec (Daily electricity kWh 4.93 5.43 8.50 5.43 8.50 5.32
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,221 1,332 2,037 1,332 2,037 1,340
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 84.0 77.5 83.0 77.5 83.0 76.6
efficiency)
Qelec (Daily electricity kWh 5.55 6.05 9.26 6.05 9.26 6.08
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Warm climate AEC (Annual kWh 966 1,123 1,784 1,123 1,784 1,110
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 106 91.8 94.0 91.8 94.0 92.3
efficiency)
Qelec (Daily electricity kWh 4.39 5.10 8.11 5.10 8.11 5.04
consumption)
Qfuel (Daily fuel kWh - 0.00
consumption)

CONNECTABLE INDOOR UNITS


EHVX11S26CB9W/ EHVX16S18CB3V/ EHVX16S26CB9W/ EHVX16S18CB3V/ EHVX16S26CB9W/
2-9 Capacity and Power input ERLQ011CV3 ERLQ014CV3 ERLQ014CV3 ERLQ016CV3 ERLQ016CV3
Heating capacity Nom. kW 11.2 / 11.0 14.5 / 13.6 16.0 / 15.2
Max. kW 8.60 / 8.60 10.6 / 10.8 11.4 / 10.9
Cooling capacity Nom. kW 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1
Power input Heating Nom. kW 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66
Max. kW 3.13 / 4.10 4.00 / 5.19 4.32 / 5.22
Cooling Nom. kW 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73
COP 4.60 / 2.75 / 3.55 / 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09
2.10
EER 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 260 l water tank 180 l water tank 260 l water tank 180 l water tank 260 l
Pump Nominal ESP unit Cooling kPa 29.8 / 1.30 59.2 / 27.2 55.0 / 18.8
Heating kPa 34.2 / 35.9 43.2 / 51.2 26.8 / 36.3
Water side Heat Water flow rate Cooling Nom. l/min 33.6 / 43.1 36.0 / 46.0 37.6 / 48.0
exchanger Heating Nom. l/min 32.1 / 31.5 41.6 / 39.0 45.9 / 43.6

42 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
3
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
2
Supplementary heater Yes
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 42.0 44.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64.0 66.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 5,400
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase kW 0.055
heater mode)
Poff (Off mode) kW 0.055
Psb (Standby mode) kW 0.055
Pto (Thermostat off) kW 0.057
Integrated NOx emission mg/kWh 0.00
supplementary Psup kW 9.00 3.00 9.00 3.00 9.00
heater Type of energy input Electrical
Space heating Average climate General SCOP 3.09 3.16 3.06
water outlet 55°C Annual kWh 6,260 7,900 8,970
energy
consump
tion
Annual Gj 22.6 28.4 32.3
energy
consump
tion
(GCV)
ηs % 120 123 119
(Season
al space
heating
efficienc
y)
Prated at kW 9.99 12.7 13.9
-10°C
Seasonal space A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/ COPd 1.99 1.76 1.78
-8°CWB) Pdh kW 8.83 9.97 12.2
PERd % 79.6 70.4 71.2
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 3.24 3.55 3.12
1°CWB)
Pdh kW 5.28 6.76 7.61
PERd % 130 142 125

• Heating • ERLQ-CV3 43
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate C Cdh (Degradation 0.950 1.00
water outlet 55°C Condition heating)
(7°CDB/ COPd 4.31 4.22 4.40
6°CWB) Pdh kW 4.47 4.66 4.83
PERd % 172 169 176
2 D Cdh (Degradation 0.930 0.940 0.930
Condition heating)
(12°CDB COPd 6.41 5.44 6.36
/
Pdh kW 5.37 5.26 5.38
11°CWB
PERd % 256 218 254
)
Tol COPd 1.79 1.75 1.71
(tempera Pdh kW 9.08 12.2 13.3
ture
PERd % 71.6 70.0 68.4
operating
limit) TOL °C -10.0
WTOL °C 55.0
Rated Psup (at kW 0.910 0.550 0.580
heat Tdesign
output -10°C)
supplem
entary
capacity
Tbiv COPd 1.99 1.92 1.78
(bivalent Pdh kW 8.83 11.0 12.2
temperat
PERd % 79.6 76.8 71.2
ure)
Tbiv °C -7.00 -6.00 -7.00
Cold climate water General Annual kWh 6,740 7,870 8,580
outlet 55°C energy
consump
tion
Annual Gj 24.3 28.3 30.9
energy
consump
tion
(GCV)
ηs % 95.0 95.5 98.3
(Season
al space
heating
efficienc
y)
Prated at kW 6.99 8.15 9.12
-22°C
Warm climate water General Annual kWh 2,630 3,270 3,420
outlet 55°C energy
consump
tion
Annual Gj 9.47 11.8 12.3
energy
consump
tion
(GCV)
ηs % 125 135 136
(Season
al space
heating
efficienc
y)
Prated at kW 7.58 9.84 10.3
2°C

44 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.98 3.90 3.80
3
water outlet 35°C Annual kWh 5,380 7,250 8,270
energy
consump
tion
Annual Gj 19.4 26.1 29.8 2
energy
consump
tion
(GCV)
ηs % 156 153 149
(Season
al space
heating
efficienc
y)
Prated at kW 11.2 14.5 16.0
-10°C
Seasonal space A++ A+
heating eff. class
A COPd 2.63 2.33
Condition Pdh kW 8.88 10.7 12.4
(-7°CDB/
PERd % 105 93.2
-8°CWB)
B Cdh (Degradation 1.00
Condition heating)
(2°CDB/ COPd 4.05 4.07 3.74
1°CWB)
Pdh kW 6.03 7.71 8.62
PERd % 162 163 150
C Cdh (Degradation 0.940 1.00 0.940
Condition heating)
(7°CDB/ COPd 6.77 5.71 6.77
6°CWB)
Pdh kW 5.74 5.05 5.74
PERd % 271 228 271
D Cdh (Degradation 0.920 0.930 0.920
Condition heating)
(12°CDB COPd 8.97 6.71 8.97
/ Pdh kW 6.50 5.16 6.50
11°CWB
PERd % 359 268 359
)
Tol COPd 2.34 2.60 2.05
(tempera Pdh kW 8.76 12.6 11.7
ture
PERd % 93.6 104 82.0
operating
TOL °C -10.0
limit)
WTOL °C 35.0
Tbiv COPd 2.82 2.83 2.56
(bivalent Pdh kW 9.09 11.6 12.1
temperat
PERd % 113 102
ure)
Tbiv °C -5.00 -4.00
Rated Psup (at kW 2.44 1.93 4.35
heat Tdesign
output -10°C)
supplem
entary
capacity

• Heating • ERLQ-CV3 45
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 6,430 8,170 9,050
outlet 35°C energy
consump
tion
ηs % 148 141 137
2 (Season
al space
heating
efficienc
y)
Prated at kW 10.3 12.3 13.3
-22°C
Qhe Gj 23.1 29.4 32.6
Annual
energy
consump
tion
(GCV)
Warm climate water General Annual kWh 1,950 2,350 2,480
outlet 35°C energy
consump
tion
Annual Gj 7.02 8.46 8.92
energy
consump
tion
(GCV)
ηs % 192 199
(Season
al space
heating
efficienc
y)
Prated at kW 9.06 10.9 11.4
2°C

46 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile XL L XL L XL
3
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,720 1,170 1,720 1,170 1,720
electricity
consumption) 2
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 97.7 87.4 97.7 87.4 97.7
efficiency)
Qelec (Daily kWh 7.83 5.32 7.83 5.32 7.83
electricity
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,980 1,340 1,980 1,340 1,980
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 85.1 76.6 85.1 76.6 85.1
efficiency)
Qelec (Daily kWh 8.99 6.08 8.99 6.08 8.99
electricity
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Warm climate AEC (Annual kWh 1,630 1,110 1,630 1,110 1,630
electricity
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 103 92.3 103 92.3 103
efficiency)
Qelec (Daily kWh 7.40 5.04 7.40 5.04 7.40
electricity
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(3) Tamb 35°C - LWE 7°C (DT=5°C)
(4) Tamb 35°C - LWE 18°C (DT=5°C)
(5) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(6) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
(7) Contains fluorinated greenhouse gases
(8) Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C

CONNECTABLE INDOOR UNITS


EHSXB04P30B/ EHSXB08P30B/ EHSXB08P50B/ EHSXB08P30B/ EHSXB08P50B/ EHSXB16P50B/
2-10 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ006CV3 ERLQ008CV3 ERLQ008CV3 ERLQ011CV3
Indoor unit EHSXB04P30 EHSXB08P30 EHSXB08P50 EHSXB08P30 EHSXB08P50 EHSXB16P50
BA BA BA BA BA BA
Outdoor unit ERLQ004CA ERLQ006CAV3 ERLQ008CAV3 ERLQ011CA
V3 V3

• Heating • ERLQ-CV3 47
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Heating capacity Min. kW 1.80 (1) / 1.81 (2) -
Nom. kW 4.26 (3) / 3.47 5.14 (3) / 4.60 (4) / 6.06 (1) / 5.53 (3) / 5.51 (4) / 7.78 (1) / 5.95 (1) / 7.74
(4) / 4.53 (1) / 5.78 (2) 7.27 (2) (2) / 11.80 (3) /
3.98 (2) 10.40 (4)
Max. kW 4.90 (1) / 5.12 8.35 (1) / 7.95 (2) 10.02 (1) / 9.53 (2) 11.38 (3) /
2 (2) 11.00 (4)
Cooling capacity Min. kW 2.0 (5) / 2.1 (6) 2.5 (5) / 2.6 (6)
Nom. kW 4.4 (5) / 4.0 (6) 5.2 (5) / 4.6 (6) 15.1 (5) / 11.7
(6)
Max. kW 5.9 (5) / 4.5 (6) 7.3 (5) / 5.5 (6) 8.4 (5) / 6.4 (6) 15.1 (5) / 11.7
(6)
Power input Heating Nom. kW 0.87 (5) / 1.04 1.30 (5) / 1.58 (6) / 1.88 (3) / 1.69 (5) / 2.04 (6) / 1.98 (3) / 2.57 (5) / 3.13
(6) / 1.49 (3) / 1.26 (4) 1.56 (4) (6) / 2.43 (1) /
0.85 (4) 2.35 (2)
Max. kW 1.12 (5) / 1.44 1.99 (5) / 2.32 (6) 2.54 (5) / 2.96 (6) 2.64 (5) / 3.25
(6) (6)
Cooling Nom. kW 1.05 (5) / 1.41 1.43 (5) / 1.85 (6) 4.55 (5) / 4.30
(6) (6)
Max. kW 1.86 (5) / 2.04 2.27 (5) / 2.51 (6) 2.89 (5) / 3.20 (6) 4.53 (5) / 4.31
(6) (6)
COP 5.23 (5) / 3.84 4.65 (5) / 3.66 (6) / 2.73 (3) / 4.60 (5) / 3.57 (6) / 2.78 (3) / 4.38 (5) / 3.32
(6) / 2.85 (3) / 3.64 (4) 3.54 (4) (6) / 2.45 (1) /
4.07 (4) 3.29 (2)
EER 4.21 (5) / 2.85 3.65 (5) / 2.51 (6) 3.32 (5) / 2.72
(6) (6)
Pump Type Grundfos UPM3 25-75 CHBL
Nominal ESP unit Cooling kPa 45.0 (7) / 48.0 44.0 (7) / 46.0 (8) -
(8)
Heating kPa 46.0 (9) / 48.0 40.0 (9) / 41.0 (10) 37.0 (9) / 36.0 (10) -
(10)
Water side Heat Water flow rate Cooling Nom. l/min 12.7 (7) / 11.5 12.9 (7) / 13.3 (8) 43.3 (7) / 33.5
exchanger (8) (8)
Heating Nom. l/min 13.0 (9) / 11.3 17.4 (9) / 16.6 (10) 22.3 (9) / 20.8 (10) 33.8 (9) / 29.8
(10) (10)
General Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61 62 64
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 -
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 0.9
Pck (Crankcase kW 0.000
heater mode)
Poff (Off mode) kW 0.011 0.012 0.050
Psb (Standby mode) kW 0.011 0.012 0.050
Pto (Thermostat off) kW 0.043 0.048 0.105
Integrated Psup kW 9.0
supplementary Type of energy input Electrical
heater

48 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General Annual kWh 2,934 3,828 4,725 6,345
3
water outlet 55°C energy
consum
ption
ηs % 132 126 128
(Season 2
al space
heating
efficienc
y)
Prated kW 5 6 8 10
at -10°C
Seasonal space A++
heating eff. class
A Condition Cdh (Degradation 1.0
(-7°CDB/- heating)
8°CWB) COPd 2.03 2.09 2.10 1.94
Pdh kW 4.2 5.3 5.4 9.0
PERd % 81.2 83.6 84.0 77.6
B Condition Cdh (Degradation 1.0
(2°CDB/ heating)
1°CWB) COPd 3.31 3.13 3.25 3.30
Pdh kW 2.6 3.1 3.9 5.4
PERd % 132.4 125.2 130.0 132.0
C Cdh (Degradation 1.0 0.9
Condition heating)
(7°CDB/ COPd 4.43 4.09 4.42 4.26
6°CWB)
Pdh kW 1.8 2.1 2.6 4.6
PERd % 177.2 163.6 176.8 170.4
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 6.55 5.99 6.30
11°CWB) Pdh kW 2.2 2.0 5.5
PERd % 262.0 239.6 252.0
Tol COPd 1.64 1.79 1.78
(temperatu Pdh kW 4.1 5.1 9.1
re PERd % 65.6 71.6 71.2
operating
TOL °C -10
limit)
WTOL °C 55
Rated heat Psup (at kW 0.7 0.9 2.4 1.0
output Tdesign
supplemen -10°C)
tary
capacity
Tbiv COPd 2.03 2.09 2.36 1.94
(bivalent Pdh kW 4.2 5.3 5.8 9.0
temperatur
PERd % 81.2 83.6 94.4 77.6
e)
Tbiv °C -7 -4 -7

• Heating • ERLQ-CV3 49
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 3,069 4,008 4,575 8,185
outlet 55°C energy
consum
ption
ηs % 110 104 109 101
2 (Season
al space
heating
efficienc
y)
Prated kW 4 5 9
at -22°C
A Condition Cdh (Degradation 1.0
(-7°CDB/- heating)
8°CWB) COPd 2.30 2.47 2.41 1.98
Pdh kW 2.2 2.6 3.2 5.2
PERd % 92.0 98.8 96.4 79.2
B Condition Cdh (Degradation 1.0 0.9 1.0
(2°CDB/ heating)
1°CWB) COPd 3.75 3.26 3.69 3.25
Pdh kW 1.4 2.0 2.4 3.2
PERd % 150.0 130.4 147.6 130.0
C Cdh (Degradation 0.9
Condition heating)
(7°CDB/ COPd 5.92 4.42 5.58 5.50
6°CWB)
Pdh kW 1.6 2.6 3.2 5.2
PERd % 236.8 176.8 223.2 220.0
D COPd 8.65 5.54 7.79 7.56
Condition Pdh kW 1.6 3.0 3.6 6.1
(12°CDB/
PERd % 346.0 221.6 311.6 302.4
11°CWB)
Tol COPd 0.89 1.05 0.98 1.22
(temperatu Pdh kW 0.8 1.0 1.2 5.7
re
PERd % 35.6 42.0 39.2 48.8
operating
TOL °C -20
limit)
WTOL °C 55
G COPd 1.25 1.42 1.33 1.51
Condition (- Pdh kW 2.9 3.6 4.3 7.1
15°CDB/-)
PERd % 50.0 56.8 53.2 60.4
Tbiv COPd 1.25 1.42 1.33 1.51
(bivalent Pdh kW 2.9 3.6 4.3 7.1
temperatur
PERd % 50.0 56.8 53.2 60.4
e)
Tbiv °C -15
Rated heat Psup (at kW 3.5 4.4 5.2 3.4
output Tdesign
supplemen -22°C)
tary
capacity

50 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 1,174 1,901 1,932 2,637
3
outlet 55°C energy
consum
ption
ηs % 186 149 176 146
(Season 2
al space
heating
efficienc
y)
Prated kW 4 5 7 8
at 2°C
B Condition Cdh (Degradation 1.0
(2°CDB/ heating)
1°CWB) COPd 2.11 2.29 2.15 1.82
Pdh kW 4.3 5.5 6.6 7.6
PERd % 84.4 91.6 86.0 72.8
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 3.76 3.41 3.70 3.07
6°CWB)
Pdh kW 2.8 3.5 4.2 4.9
PERd % 150.4 136.4 148.0 122.8
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 7.26 4.86 6.52 5.88
11°CWB)
Pdh kW 1.6 2.9 3.5 5.4
PERd % 290.4 194.4 260.8 235.2
Tbiv COPd 2.11 2.29 2.15 1.82
(bivalent Pdh kW 4.3 5.5 6.6 7.6
temperatur
PERd % 84.4 91.6 86.0 72.8
e)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Season
al space
heating
efficienc
y)
Cold climate water General ηs % -
outlet 35°C (Season
al space
heating
efficienc
y)
Qhe Gj -
Annual
energy
consum
ption
(GCV)
Warm climate water General ηs % -
outlet 35°C (Season
al space
heating
efficienc
y)

• Heating • ERLQ-CV3 51
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile L XL L XL
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,063 1,148 1,654 1,256 1,797 2,158
electricity
2 consumption)
ηwh (water heating % 103 98 108 90 99 84
efficiency)
Qelec (Daily electricity kWh 4.753 5.138 7.453 5.630 8.105 9.681
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,221 1,263 1,858 1,387 2,200 2,394
electricity
consumption)
ηwh (water heating % 92 89 95 80 76
efficiency)
Qelec (Daily electricity kWh 5.473 5.653 8.379 6.226 10.000 10.755
consumption)
Warm climate AEC (Annual kWh 948 1,068 1,510 1,138 1,696 1,921
electricity
consumption)
ηwh (water heating % 120 107 117 100 106 95
efficiency)
Qelec (Daily electricity kWh 4.229 4.763 6.796 5.091 8.000 8.600
consumption)

CONNECTABLE INDOOR UNITS


2-11 Capacity and Power input EHSXB16P50B/ERLQ014CV3 EHSXB16P50B/ERLQ016CV3
Indoor unit EHSXB16P50BA
Outdoor unit ERLQ014CAV3 ERLQ016CAV3
Heating capacity Nom. kW 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Max. kW 14.55 / 13.59 16.10 / 15.22
Cooling capacity Min. kW 2.5 / 2.6 -
Nom. kW 16.1 / 12.6 16.8 / 13.1
Max. kW 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 3.42 / 4.07 / 3.17 / 2.93
Max. kW 3.43 / 4.22 3.83 / 4.71
Cooling Nom. kW 5.44 / 5.10 6.18 / 5.72
Max. kW 5.42 / 5.09 6.15 / 5.74
COP 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
EER 2.96 / 2.47 2.72 / 2.29
Pump Type Grundfos UPM3 25-75 CHBL
Water side Heat Water flow rate Cooling Nom. l/min 46.0 / 36.1 48.1 / 37.5
exchanger Heating Nom. l/min 42.4 / 39.4 44.0 / 42.6
General Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64 66
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825

52 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating general Other Capacity control Inverter
3
Cdh (Degradation heating) 0.9
Pck (Crankcase kW 0.000
heater mode)
Poff (Off mode) kW 0.050
Psb (Standby mode) kW 0.050 2
Pto (Thermostat off) kW 0.105
Integrated Psup kW 9.0
supplementary heater Type of energy input Electrical
Space heating Average climate General Annual kWh 7,654 8,978
water outlet 55°C energy
consumpt
ion
ηs % 130 127
(Seasonal
space
heating
efficiency)
Prated at kW 12 14
-10°C
Seasonal space A++
heating eff. class
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 1.92 1.85
-8°CWB)
Pdh kW 10.9 12.6
PERd % 76.8 74.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.30 3.19
1°CWB)
Pdh kW 6.6 7.8
PERd % 132.0 127.6
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 4.34 4.47
6°CWB)
Pdh kW 4.6 4.9
PERd % 173.6 178.8
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 6.45 6.52
11°CWB) Pdh kW 5.5 5.4
PERd % 258.0 260.8
Tol COPd 1.63 1.57
(temperat Pdh kW 9.8 11.2
ure PERd % 65.2 62.8
operating
TOL °C -10
limit)
WTOL °C 55
Rated Psup (at kW 2.5 3.0
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 1.92 1.84
(bivalent Pdh kW 10.9 12.6
temperat
PERd % 76.8 73.6
ure)
Tbiv °C -7

• Heating • ERLQ-CV3 53
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 9,676 10,405
outlet 55°C energy
consumpt
ion
ηs % 101
2 (Seasonal
space
heating
efficiency)
Prated at kW 10 11
-22°C
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 2.04 2.05
-8°CWB)
Pdh kW 6.2 6.6
PERd % 81.6 82.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.20 3.19
1°CWB) Pdh kW 3.8 4.0
PERd % 128.0 127.6
C Cdh (Degradation 0.9
Condition heating)
(7°CDB/ COPd 5.50
6°CWB)
Pdh kW 5.2
PERd % 220.0
D COPd 7.56
Condition Pdh kW 6.1
(12°CDB/ PERd % 302.4
11°CWB)
Tol COPd 1.13 1.08
(temperat Pdh kW 6.4 6.8
ure PERd % 45.2 43.2
operating
TOL °C -20
limit)
WTOL °C 55
G COPd 1.50 1.42
Condition Pdh kW 8.4 8.9
(- PERd % 60.0 56.8
15°CDB/-
)
Tbiv COPd 1.50 1.42
(bivalent Pdh kW 8.4 8.9
temperat
PERd % 60.0 56.8
ure)
Tbiv °C -15
Rated Psup (at kW 4.6 4.9
heat Tdesign -
output 22°C)
suppleme
ntary
capacity

54 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 3,282 3,429
3
outlet 55°C energy
consumpt
ion
ηs % 153 154
(Seasonal 2
space
heating
efficiency)
Prated at kW 10
2°C
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 1.90 1.78
1°CWB)
Pdh kW 9.8 10.3
PERd % 76.0 71.2
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 3.22 3.25
6°CWB) Pdh kW 6.3 6.6
PERd % 128.8 130.0
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 5.88
11°CWB)
Pdh kW 5.4
PERd % 235.2
Tbiv COPd 1.90 1.78
(bivalent Pdh kW 9.8 10.3
temperat PERd % 76.0 71.2
ure)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Seasonal
space
heating
efficiency)
Cold climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
Qhe Gj -
Annual
energy
consumpt
ion (GCV)
Warm climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)

• Heating • ERLQ-CV3 55
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile XL
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 2,158
electricity
2 consumption)
ηwh (water heating % 84
efficiency)
Qelec (Daily electricity kWh 9.681
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 2,394
electricity
consumption)
ηwh (water heating % 76
efficiency)
Qelec (Daily electricity kWh 10.755
consumption)
Warm climate AEC (Annual kWh 1,921
electricity
consumption)
ηwh (water heating % 95
efficiency)
Qelec (Daily electricity kWh 8.600
consumption)

Notes

(1) EW 30°C; LW 35°C; ambient conditions: 7°CDB/6°CWB


(2) EW 40°C; LW 45°C; ambient conditions: 7°CDB/6°CWB
(3) EW 30°C; LW 35°C; ambient conditions: -7°CDB/-8°CWB
(4) EW 30°C; LW 35°C; ambient conditions: 2°CDB/1°CWB
(5) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(6) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(7) Tamb 35°C - LWE 18°C (DT=5°C)
(8) Tamb 35°C - LWE 7°C (DT=5°C)
(9) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(10) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

CONNECTABLE INDOOR UNITS


EHSH04P30B/ EHSH08P30B/ EHSH08P50B/ EHSH08P30B/ EHSH08P50B/ EHSH16P50B/
2-12 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ006CV3 ERLQ008CV3 ERLQ008CV3 ERLQ011CV3
Indoor unit EHSH04P30B EHSH08P30B EHSH08P50B EHSH08P30B EHSH08P50B EHSH16P50B
A A A A A A
Outdoor unit ERLQ004CAV ERLQ006CAV3 ERLQ008CAV3 ERLQ011CAV
3 3
Heating capacity Min. kW 1.80 (1) / 1.81 (2) -
Nom. kW 4.26 (3) / 3.47 5.14 (3) / 4.60 (4) / 6.06 (1) / 5.78 5.53 (3) / 5.51 (4) / 7.78 (1) / 7.27 5.95 (1) / 7.74
(4) / 4.53 (1) / (2) (2) (2) / 11.80 (3) /
3.98 (2) 10.40 (4)
Max. kW 4.90 (1) / 5.12 8.35 (1) / 7.95 (2) 10.02 (1) / 9.53 (2) 11.38 (3) /
(2) 11.00 (4)
Power input Heating Nom. kW 0.87 (5) / 1.04 1.30 (5) / 1.58 (6) / 1.88 (3) / 1.26 1.69 (5) / 2.04 (6) / 1.98 (3) / 1.56 2.57 (5) / 3.13
(6) / 1.49 (3) / (4) (4) (6) / 2.43 (1) /
0.85 (4) 2.35 (2)
Max. kW 1.12 (5) / 1.44 1.99 (5) / 2.32 (6) 2.54 (5) / 2.96 (6) 2.64 (5) / 3.25
(6) (6)
COP 5.23 (5) / 3.84 4.65 (5) / 3.66 (6) / 2.73 (3) / 3.64 4.60 (5) / 3.57 (6) / 2.78 (3) / 3.54 4.38 (5) / 3.32
(6) / 2.85 (3) / (4) (4) (6) / 2.45 (1) /
4.07 (4) 3.29 (2)

56 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Pump Type Grundfos UPM3 25-75 CHBL
3
Nominal ESP unit Heating kPa 46.0 (7) / 48.0 40.0 (7) / 41.0 (8) 37.0 (7) / 36.0 (8) -
(8)
Water side Heat Water flow rate Heating Nom. l/min 13.0 (7) / 11.3 17.4 (7) / 16.6 (8) 22.3 (7) / 20.8 (8) 33.8 (7) / 29.8
exchanger (8) (8)
General Product description Air-to-water heat pump Yes 2
Brine-to-water heat pump No
Heat pump combination Yes
heater
Low-temperature heat pump No
Supplementary heater No
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61 62 64
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 -
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 0.9
Pck (Crankcase kW 0.000
heater mode)
Poff (Off mode) kW 0.011 0.012 0.050
Psb (Standby kW 0.011 0.012 0.050
mode)
Pto (Thermostat off) kW 0.043 0.048 0.105
Integrated Psup kW 9.0
supplementary Type of energy input Electrical
heater
Space heating Average climate General Annual kWh 2,934 3,828 4,725 6,345
water outlet 55°C energy
consum
ption
ηs % 130 125 127 125
(Seaso
nal
space
heating
efficien
cy)
Prated kW 5 6 8 10
at -
10°C
Seasonal space A++
heating eff. class
A Cdh 1.0
Condition (Degradation
(-7°CDB/- heating)
8°CWB) COPd 2.03 2.09 2.10 1.94
Pdh kW 4.2 5.3 5.4 9.0
PERd % 81.2 83.6 84.0 77.6
B Cdh 1.0
Condition (Degradation
(2°CDB/ heating)
1°CWB) COPd 3.31 3.13 3.25 3.30
Pdh kW 2.6 3.1 3.9 5.4
PERd % 132.4 125.2 130.0 132.0

• Heating • ERLQ-CV3 57
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate C Cdh 1.0 0.9
water outlet 55°C Condition (Degradation
(7°CDB/ heating)
6°CWB) COPd 4.43 4.09 4.42 4.26
Pdh kW 1.8 2.1 2.6 4.6
2 PERd % 177.2 163.6 176.8 170.4
D Cdh 0.9
Condition (Degradation
(12°CDB/ heating)
11°CWB) COPd 6.55 5.99 6.30
Pdh kW 2.2 2.0 5.5
PERd % 262.0 239.6 252.0
Tol COPd 1.64 1.79 1.78
(temperat Pdh kW 4.1 5.1 9.1
ure PERd % 65.6 71.6 71.2
operating
TOL °C -10
limit)
WTOL °C 55
Rated Psup kW 0.7 0.9 2.4 1.0
heat (at
output Tdesig
suppleme n-
ntary 10°C)
capacity
Tbiv COPd 2.03 2.09 2.36 1.94
(bivalent Pdh kW 4.2 5.3 5.8 9.0
temperatu
PERd % 81.2 83.6 94.4 77.6
re)
Tbiv °C -7 -4 -7

58 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 3,069 4,008 4,575 8,185
3
outlet 55°C energy
consum
ption
ηs % 109 103 109 100
(Seaso 2
nal
space
heating
efficien
cy)
Prated kW 4 5 9
at -
22°C
A Cdh 1.0
Condition (Degradation
(-7°CDB/- heating)
8°CWB) COPd 2.30 2.47 2.41 1.98
Pdh kW 2.2 2.6 3.2 5.2
PERd % 92.0 98.8 96.4 79.2
B Cdh 1.0 0.9 1.0
Condition (Degradation
(2°CDB/ heating)
1°CWB) COPd 3.75 3.26 3.69 3.25
Pdh kW 1.4 2.0 2.4 3.2
PERd % 150.0 130.4 147.6 130.0
C Cdh 0.9
Condition (Degradation
(7°CDB/ heating)
6°CWB) COPd 5.92 4.42 5.58 5.50
Pdh kW 1.6 2.6 3.2 5.2
PERd % 236.8 176.8 223.2 220.0
D COPd 8.65 5.54 7.79 7.56
Condition Pdh kW 1.6 3.0 3.6 6.1
(12°CDB/ PERd % 346.0 221.6 311.6 302.4
11°CWB)
Tol COPd 0.89 1.05 0.98 1.22
(temperat Pdh kW 0.8 1.0 1.2 5.7
ure PERd % 35.6 42.0 39.2 48.8
operating
TOL °C -20
limit)
WTOL °C 55 1 55
G COPd 1.25 1.42 1.33 1.51
Condition Pdh kW 2.9 3.6 4.3 7.1
(- PERd % 50.0 56.8 53.2 60.4
15°CDB/-
)
Tbiv COPd 1.25 1.42 1.33 1.51
(bivalent Pdh kW 2.9 3.6 4.3 7.1
temperatu
PERd % 50.0 56.8 53.2 60.4
re)
Tbiv °C -15
Rated Psup kW 3.5 4.4 5.2 3.4
heat (at
output Tdesig
suppleme n-
ntary 22°C)
capacity

• Heating • ERLQ-CV3 59
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 1,174 1,901 1,932 2,637
outlet 55°C energy
consum
ption
ηs % 179 145 171 135
2 (Seaso
nal
space
heating
efficien
cy)
Prated kW 4 5 7 8
at 2°C
B Cdh 1.0
Condition (Degradation
(2°CDB/ heating)
1°CWB) COPd 2.11 2.29 2.15 1.82
Pdh kW 4.3 5.5 6.6 7.6
PERd % 84.4 91.6 86.0 72.8
C Cdh 1.0
Condition (Degradation
(7°CDB/ heating)
6°CWB) COPd 3.76 3.41 3.70 3.07
Pdh kW 2.8 3.5 4.2 4.9
PERd % 150.4 136.4 148.0 122.8
D Cdh 0.9
Condition (Degradation
(12°CDB/ heating)
11°CWB) COPd 7.26 4.86 6.52 5.88
Pdh kW 1.6 2.9 3.5 5.4
PERd % 290.4 194.4 260.8 235.2
Tbiv COPd 2.11 2.29 2.15 1.82
(bivalent Pdh kW 4.3 5.5 6.6 7.6
temperatu
PERd % 84.4 91.6 86.0 72.8
re)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Seaso
nal
space
heating
efficien
cy)
Cold climate water General ηs % -
outlet 35°C (Seaso
nal
space
heating
efficien
cy)
Qhe Gj -
Annual
energy
consum
ption
(GCV)
Warm climate water General ηs % -
outlet 35°C (Seaso
nal
space
heating
efficien
cy)

60 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile L XL L XL
3
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,063 1,148 1,747 1,256 1,866 2,187
electricity
consumption) 2
ηwh (water heating % 103 98 102 90 96 83
efficiency)
Qelec (Daily kWh 4.753 5.138 7.866 5.630 8.409 9.811
electricity
consumption)
Water heating energy A
efficiency class
Cold climate AEC (Annual kWh 1,221 1,263 1,954 1,387 2,104 2,435
electricity
consumption)
ηwh (water heating % 92 89 91 80 84 74
efficiency)
Qelec (Daily kWh 5.473 5.653 9.000 6.226 9.496 10.938
electricity
consumption)
Warm climate AEC (Annual kWh 948 1,068 1,559 1,138 1,727 1,956
electricity
consumption)
ηwh (water heating % 120 107 115 100 104 93
efficiency)
Qelec (Daily kWh 4.229 4.763 7.014 5.091 8.000 8.760
electricity
consumption)

CONNECTABLE INDOOR UNITS


2-13 Capacity and Power input EHSH16P50B/ERLQ014CV3 EHSH16P50B/ERLQ016CV3
Indoor unit EHSH16P50BA
Outdoor unit ERLQ014CAV3 ERLQ016CAV3
Heating capacity Nom. kW 8.28 / 9.57 / 14.81 / 13.73 15.34 / 14.86 / 8.04 / 10.05
Max. kW 14.55 / 13.59 16.10 / 15.22
Power input Heating Nom. kW 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
Max. kW 3.43 / 4.22 3.83 / 4.71
COP 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
Pump Type Grundfos UPM3 25-75 CHBL
Water side Heat Water flow rate Heating Nom. l/min 42.4 / 39.4 44.0 / 42.6
exchanger
General Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater No
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64 66
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825

• Heating • ERLQ-CV3 61
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating general Other Capacity control Inverter
Cdh (Degradation heating) 0.9
Pck (Crankcase kW 0.000
heater mode)
Poff (Off mode) kW 0.050
2 Psb (Standby mode) kW 0.050
Pto (Thermostat off) kW 0.105
Integrated Psup kW 9.0
supplementary Type of energy input Electrical
heater
Space heating Average climate General Annual kWh 7,654 8,978
water outlet 55°C energy
consum
ption
ηs % 126 125
(Season
al space
heating
efficienc
y)
Prated kW 12 14
at -10°C
Seasonal space A++
heating eff. class
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/- COPd 1.92 1.85
8°CWB) Pdh kW 10.9 12.6
PERd % 76.8 74.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.30 3.19
1°CWB)
Pdh kW 6.6 7.8
PERd % 132.0 127.6
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 4.34 4.47
6°CWB)
Pdh kW 4.6 4.9
PERd % 173.6 178.8
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 6.45 6.52
11°CWB) Pdh kW 5.5 5.4
PERd % 258.0 260.8
Tol COPd 1.63 1.57
(temperat Pdh kW 9.8 11.2
ure PERd % 65.2 62.8
operating
TOL °C -10
limit)
WTOL °C 55
Rated Psup (at kW 2.5 3.0
heat Tdesign
output -10°C)
suppleme
ntary
capacity
Tbiv COPd 1.92 1.84
(bivalent Pdh kW 10.9 12.6
temperatu
PERd % 76.8 73.6
re)
Tbiv °C -7

62 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 9,676 10,405
3
outlet 55°C energy
consum
ption
ηs % 100
(Season 2
al space
heating
efficienc
y)
Prated kW 10 11
at -22°C
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/- COPd 2.04 2.05
8°CWB) Pdh kW 6.2 6.6
PERd % 81.6 82.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.20 3.19
1°CWB)
Pdh kW 3.8 4.0
PERd % 128.0 127.6
C Cdh (Degradation 0.9
Condition heating)
(7°CDB/ COPd 5.50
6°CWB)
Pdh kW 5.2
PERd % 220.0
D COPd 7.56
Condition Pdh kW 6.1
(12°CDB/
PERd % 302.4
11°CWB)
Tol COPd 1.13 1.08
(temperat Pdh kW 6.4 6.8
ure
PERd % 45.2 43.2
operating
TOL °C -20
limit)
WTOL °C 55
G COPd 1.50 1.42
Condition Pdh kW 8.4 8.9
(-
PERd % 60.0 56.8
15°CDB/-
)
Tbiv COPd 1.50 1.42
(bivalent Pdh kW 8.4 8.9
temperatu
PERd % 60.0 56.8
re)
Tbiv °C -15
Rated Psup (at kW 4.6 4.9
heat Tdesign
output -22°C)
suppleme
ntary
capacity

• Heating • ERLQ-CV3 63
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 3,282 3,429
outlet 55°C energy
consum
ption
ηs % 144 145
2 (Season
al space
heating
efficienc
y)
Prated kW 10
at 2°C
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 1.90 1.78
1°CWB) Pdh kW 9.8 10.3
PERd % 76.0 71.2
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 3.22 3.25
6°CWB)
Pdh kW 6.3 6.6
PERd % 128.8 130.0
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 5.88
11°CWB)
Pdh kW 5.4
PERd % 235.2
Tbiv COPd 1.90 1.78
(bivalent Pdh kW 9.8 10.3
temperatu
PERd % 76.0 71.2
re)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Season
al space
heating
efficienc
y)
Cold climate water General ηs % -
outlet 35°C (Season
al space
heating
efficienc
y)
Qhe Gj -
Annual
energy
consum
ption
(GCV)
Warm climate water General ηs % -
outlet 35°C (Season
al space
heating
efficienc
y)

64 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile XL
3
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 2,187
electricity
consumption) 2
ηwh (water heating % 83
efficiency)
Qelec (Daily kWh 9.811
electricity
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 2,435
electricity
consumption)
ηwh (water heating % 74
efficiency)
Qelec (Daily kWh 10.938
electricity
consumption)
Warm climate AEC (Annual kWh 1,956
electricity
consumption)
ηwh (water heating % 93
efficiency)
Qelec (Daily kWh 8.760
electricity
consumption)

Notes

(1) EW 30°C; LW 35°C; ambient conditions: 7°CDB/6°CWB


(2) EW 40°C; LW 45°C; ambient conditions: 7°CDB/6°CWB
(3) EW 30°C; LW 35°C; ambient conditions: -7°CDB/-8°CWB
(4) EW 30°C; LW 35°C; ambient conditions: 2°CDB/1°CWB
(5) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(6) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(7) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(8) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

CONNECTABLE INDOOR UNITS


EHSX04P30B/ EHSX08P50B/ EHSX08P30B/ EHSX08P30B/ EHSX08P50B/ EHSX16P50B/
2-14 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ006CV3 ERLQ008CV3 ERLQ008CV3 ERLQ011CV3
Indoor unit EHSX04P30B EHSX08P50B EHSX08P30BA EHSX08P50B EHSX16P50B
A A A A
Outdoor unit ERLQ004CAV ERLQ006CAV3 ERLQ008CAV3 ERLQ011CAV
3 3
Heating capacity Min. kW 1.80 (1) / 1.81 (2) -
Nom. kW 4.26 (3) / 3.47 5.14 (3) / 4.60 (4) / 6.06 (1) / 5.53 (3) / 5.51 (4) / 7.78 (1) / 5.95 (1) / 7.74
(4) / 4.53 (1) / 5.78 (2) 7.27 (2) (2) / 11.80 (3) /
3.98 (2) 10.40 (4)
Max. kW 4.90 (1) / 5.12 8.35 (1) / 7.95 (2) 10.02 (1) / 9.53 (2) 11.38 (3) /
(2) 11.00 (4)
Cooling capacity Min. kW 2.0 (5) / 2.1 (6) 2.5 (5) / 2.6 (6)
Nom. kW 4.4 (5) / 4.0 (6) 5.2 (5) / 4.6 (6) 15.1 (5) / 11.7
(6)
Max. kW 5.9 (5) / 4.5 (6) 7.3 (5) / 5.5 (6) 8.4 (5) / 6.4 (6) 15.1 (5) / 11.7
(6)

• Heating • ERLQ-CV3 65
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Power input Heating Nom. kW 0.87 (5) / 1.04 1.30 (5) / 1.58 (6) / 1.88 (3) / 1.69 (5) / 2.04 (6) / 1.98 (3) / 2.57 (5) / 3.13
(6) / 1.49 (3) / 1.26 (4) 1.56 (4) (6) / 2.43 (1) /
0.85 (4) 2.35 (2)
Max. kW 1.12 (5) / 1.44 1.99 (5) / 2.32 (6) 2.54 (5) / 2.96 (6) 2.64 (5) / 3.25
(6) (6)
2 Cooling Nom. kW 1.05 (5) / 1.41 1.43 (5) / 1.85 (6) 4.55 (5) / 4.30
(6) (6)
Max. kW 1.86 (5) / 2.04 2.27 (5) / 2.51 (6) 2.89 (5) / 3.20 (6) 4.53 (5) / 4.31
(6) (6)
COP 5.23 (5) / 3.84 4.65 (5) / 3.66 (6) / 2.73 (3) / 4.60 (5) / 3.57 (6) / 2.78 (3) / 4.38 (5) / 3.32
(6) / 2.85 (3) / 3.64 (4) 3.54 (4) (6) / 2.45 (1) /
4.07 (4) 3.29 (2)
EER 4.21 (5) / 2.85 3.65 (5) / 2.51 (6) 3.32 (5) / 2.72
(6) (6)
Pump Type Grundfos UPM3 25-75 CHBL
Nominal ESP unit Cooling kPa 45.0 (7) / 48.0 - 44.0 (7) / 46.0 (8) -
(8)
Heating kPa 46.0 (9) / 48.0 40.0 (7) / 41.0 40.0 (9) / 41.0 37.0 (9) / 36.0 (10) -
(10) (8) (10)
Water side Heat Water flow rate Cooling Nom. l/min 12.7 (7) / 11.5 - 12.9 (7) / 13.3 (8) 43.3 (7) / 33.5
exchanger (8) (8)
Heating Nom. l/min 13.0 (9) / 11.3 17.4 (7) / 16.6 17.4 (9) / 16.6 22.3 (9) / 20.8 (10) 33.8 (9) / 29.8
(10) (8) (10) (10)
General Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater No
integrated
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61 62 64
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 -
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 0.9
Pck (Crankcase kW 0.000
heater mode)
Poff (Off mode) kW 0.011 0.012 0.050
Psb (Standby mode) kW 0.011 0.012 0.050
Pto (Thermostat off) kW 0.043 0.048 0.105
Integrated Psup kW 9.0
supplementary Type of energy input Electrical
heater

66 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General Annual kWh 2,934 3,828 4,725 6,345
3
water outlet 55°C energy
consum
ption
ηs % 132 126 128
(Season 2
al space
heating
efficienc
y)
Prated kW 5 6 8 10
at -10°C
Seasonal space A++
heating eff. class
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 2.03 2.09 2.10 1.94
-8°CWB)
Pdh kW 4.2 5.3 5.4 9.0
PERd % 81.2 83.6 84.0 77.6
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.31 3.13 3.25 3.30
1°CWB)
Pdh kW 2.6 3.1 3.9 5.4
PERd % 132.4 125.2 130.0 132.0
C Cdh (Degradation 1.0 0.9
Condition heating)
(7°CDB/ COPd 4.43 4.09 4.42 4.26
6°CWB)
Pdh kW 1.8 2.1 2.6 4.6
PERd % 177.2 163.6 176.8 170.4
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 6.55 5.99 6.30
11°CWB) Pdh kW 2.2 2.0 5.5
PERd % 262.0 239.6 252.0
Tol COPd 1.64 1.79 1.78
(temperat Pdh kW 4.1 5.1 9.1
ure PERd % 65.6 71.6 71.2
operating
TOL °C -10
limit)
WTOL °C 55
Rated Psup (at kW 0.7 0.9 2.4 1.0
heat Tdesign
output -10°C)
suppleme
ntary
capacity
Tbiv COPd 2.03 2.09 2.36 1.94
(bivalent Pdh kW 4.2 5.3 5.8 9.0
temperat
PERd % 81.2 83.6 94.4 77.6
ure)
Tbiv °C -7 -4 -7

• Heating • ERLQ-CV3 67
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 3,069 4,008 4,575 8,185
outlet 55°C energy
consum
ption
ηs % 110 103 104 109 100
2 (Season
al space
heating
efficienc
y)
Prated kW 4 5 9
at -22°C
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 2.30 2.47 2.41 1.98
-8°CWB) Pdh kW 2.2 2.6 3.2 5.2
PERd % 92.0 98.8 96.4 79.2
B Cdh (Degradation 1.0 0.9 1.0
Condition heating)
(2°CDB/ COPd 3.75 3.26 3.69 3.25
1°CWB)
Pdh kW 1.4 2.0 2.4 3.2
PERd % 150.0 130.4 147.6 130.0
C Cdh (Degradation 0.9
Condition heating)
(7°CDB/ COPd 5.92 4.42 5.58 5.50
6°CWB)
Pdh kW 1.6 2.6 3.2 5.2
PERd % 236.8 176.8 223.2 220.0
D COPd 8.65 5.54 7.79 7.56
Condition Pdh kW 1.6 3.0 3.6 6.1
(12°CDB/
PERd % 346.0 221.6 311.6 302.4
11°CWB)
Tol COPd 0.89 1.05 0.98 1.22
(temperat Pdh kW 0.8 1.0 1.2 5.7
ure
PERd % 35.6 42.0 39.2 48.8
operating
TOL °C -20
limit)
WTOL °C 55
G COPd 1.25 1.42 1.33 1.51
Condition Pdh kW 2.9 3.6 4.3 7.1
(-
PERd % 50.0 56.8 53.2 60.4
15°CDB/-
)
Tbiv COPd 1.25 1.42 1.33 1.51
(bivalent Pdh kW 2.9 3.6 4.3 7.1
temperat
PERd % 50.0 56.8 53.2 60.4
ure)
Tbiv °C -15
Rated Psup (at kW 3.5 4.4 5.2 3.4
heat Tdesign
output -22°C)
suppleme
ntary
capacity

68 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 1,174 1,901 1,932 2,637
3
outlet 55°C energy
consum
ption
ηs % 186 145 149 176 135
(Season 2
al space
heating
efficienc
y)
Prated kW 4 5 7 8
at 2°C
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 2.11 2.29 2.15 1.82
1°CWB) Pdh kW 4.3 5.5 6.6 7.6
PERd % 84.4 91.6 86.0 72.8
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 3.76 3.41 3.70 3.07
6°CWB)
Pdh kW 2.8 3.5 4.2 4.9
PERd % 150.4 136.4 148.0 122.8
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 7.26 4.86 6.52 5.88
11°CWB)
Pdh kW 1.6 2.9 3.5 5.4
PERd % 290.4 194.4 260.8 235.2
Tbiv COPd 2.11 2.29 2.15 1.82
(bivalent Pdh kW 4.3 5.5 6.6 7.6
temperat
PERd % 84.4 91.6 86.0 72.8
ure)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Season
al space
heating
efficienc
y)
Cold climate water General ηs % -
outlet 35°C (Season
al space
heating
efficienc
y)
Qhe Gj -
Annual
energy
consum
ption
(GCV)
Warm climate water General ηs % -
outlet 35°C (Season
al space
heating
efficienc
y)

• Heating • ERLQ-CV3 69
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile L XL L XL
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,063 1,747 1,148 1,256 1,866 2,187
electricity
2 consumption)
ηwh (water heating % 103 102 98 90 96 83
efficiency)
Qelec (Daily kWh 4.753 7.866 5.138 5.630 8.409 9.811
electricity
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,221 1,954 1,263 1,387 2,104 2,435
electricity
consumption)
ηwh (water heating % 92 91 89 80 84 74
efficiency)
Qelec (Daily kWh 5.473 9.000 5.653 6.226 9.496 10.938
electricity
consumption)
Warm climate AEC (Annual kWh 948 1,559 1,068 1,138 1,727 1,956
electricity
consumption)
ηwh (water heating % 120 115 107 100 104 93
efficiency)
Qelec (Daily kWh 4.229 7.014 4.763 5.091 8.000 8.760
electricity
consumption)

CONNECTABLE INDOOR UNITS


2-15 Capacity and Power input EHSX16P50B/ERLQ014CV3 EHSH16P50B/ERLQ016CV3
Indoor unit EHSX16P50BA
Outdoor unit ERLQ014CAV3 ERLQ016CAV3
Heating capacity Nom. kW 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Max. kW 14.55 / 13.59 16.10 / 15.22
Cooling capacity Min. kW 2.5 / 2.6 -
Nom. kW 16.1 / 12.6 16.8 / 13.1
Max. kW 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 3.42 / 4.07 / 3.17 / 2.93
Max. kW 3.43 / 4.22 3.83 / 4.71
Cooling Nom. kW 5.44 / 5.10 6.18 / 5.72
Max. kW 5.42 / 5.09 6.15 / 5.74
COP 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
EER 2.96 / 2.47 2.72 / 2.29
Pump Type Grundfos UPM3 25-75 CHBL
Water side Heat Water flow rate Cooling Nom. l/min 46.0 / 36.1 48.1 / 37.5
exchanger Heating Nom. l/min 42.4 / 39.4 44.0 / 42.6
General Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64 66
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825

70 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating general Other Capacity control Inverter
3
Cdh (Degradation heating) 0.9
Pck (Crankcase kW 0.000
heater mode)
Poff (Off mode) kW 0.050
Psb (Standby mode) kW 0.050 2
Pto (Thermostat off) kW 0.105
Integrated Psup kW 9.0
supplementary Type of energy input Electrical
heater
Space heating Average climate General Annual kWh 7,654 8,978
water outlet 55°C energy
consumpt
ion
ηs % 130 127
(Seasonal
space
heating
efficiency)
Prated at kW 12 14
-10°C
Seasonal space A++
heating eff. class
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 1.92 1.85
-8°CWB)
Pdh kW 10.9 12.6
PERd % 76.8 74.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.30 3.19
1°CWB) Pdh kW 6.6 7.8
PERd % 132.0 127.6
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 4.34 4.47
6°CWB)
Pdh kW 4.6 4.9
PERd % 173.6 178.8
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 6.45 6.52
11°CWB)
Pdh kW 5.5 5.4
PERd % 258.0 260.8
Tol COPd 1.63 1.57
(temperat Pdh kW 9.8 11.2
ure
PERd % 65.2 62.8
operating
limit) TOL °C -10
WTOL °C 55
Rated Psup (at kW 2.5 3.0
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 1.92 1.84
(bivalent Pdh kW 10.9 12.6
temperat
PERd % 76.8 73.6
ure)
Tbiv °C -7

• Heating • ERLQ-CV3 71
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 9,676 10,405
outlet 55°C energy
consumpt
ion
ηs % 101
2 (Seasonal
space
heating
efficiency)
Prated at kW 10 11
-22°C
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 2.04 2.05
-8°CWB)
Pdh kW 6.2 6.6
PERd % 81.6 82.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.20 3.19
1°CWB) Pdh kW 3.8 4.0
PERd % 128.0 127.6
C Cdh (Degradation 0.9
Condition heating)
(7°CDB/ COPd 5.50
6°CWB)
Pdh kW 5.2
PERd % 220.0
D COPd 7.56
Condition Pdh kW 6.1
(12°CDB/ PERd % 302.4
11°CWB)
Tol COPd 1.13 1.08
(temperat Pdh kW 6.4 6.8
ure PERd % 45.2 43.2
operating
TOL °C -20
limit)
WTOL °C 55
G COPd 1.50 1.42
Condition Pdh kW 8.4 8.9
(- PERd % 60.0 56.8
15°CDB/-
)
Tbiv COPd 1.50 1.42
(bivalent Pdh kW 8.4 8.9
temperat
PERd % 60.0 56.8
ure)
Tbiv °C -15
Rated Psup (at kW 4.6 4.9
heat Tdesign -
output 22°C)
suppleme
ntary
capacity

72 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 3,282 3,429
3
outlet 55°C energy
consumpt
ion
ηs % 153 154
(Seasonal 2
space
heating
efficiency)
Prated at kW 10
2°C
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 1.90 1.78
1°CWB)
Pdh kW 9.8 10.3
PERd % 76.0 71.2
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 3.22 3.25
6°CWB) Pdh kW 6.3 6.6
PERd % 128.8 130.0
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 5.88
11°CWB)
Pdh kW 5.4
PERd % 235.2
Tbiv COPd 1.90 1.78
(bivalent Pdh kW 9.8 10.3
temperat PERd % 76.0 71.2
ure)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Seasonal
space
heating
efficiency)
Cold climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
Qhe Gj -
Annual
energy
consumpt
ion (GCV)
Warm climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)

• Heating • ERLQ-CV3 73
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile XL
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 2,187
electricity
2 consumption)
ηwh (water heating % 83
efficiency)
Qelec (Daily electricity kWh 9.811
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 2,435
electricity
consumption)
ηwh (water heating % 74
efficiency)
Qelec (Daily electricity kWh 10.938
consumption)
Warm climate AEC (Annual kWh 1,956
electricity
consumption)
ηwh (water heating % 93
efficiency)
Qelec (Daily electricity kWh 8.760
consumption)

Notes

(1) EW 30°C; LW 35°C; ambient conditions: 7°CDB/6°CWB


(2) EW 40°C; LW 45°C; ambient conditions: 7°CDB/6°CWB
(3) EW 30°C; LW 35°C; ambient conditions: -7°CDB/-8°CWB
(4) EW 30°C; LW 35°C; ambient conditions: 2°CDB/1°CWB
(5) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(6) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(7) Tamb 35°C - LWE 18°C (DT=5°C)
(8) Tamb 35°C - LWE 7°C (DT=5°C)
(9) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(10) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

CONNECTABLE INDOOR UNITS


EHSHB04P30B EHSHB08P30B EHSHB08P50B EHSHB08P30B EHSHB08P50B EHSHB16P50B
2-16 Capacity and Power input /ERLQ004CV3 /ERLQ006CV3 /ERLQ006CV3 /ERLQ008CV3 /ERLQ008CV3 /ERLQ011CV3
Indoor unit EHSHB04P30 EHSHB08P30 EHSHB08P50 EHSHB08P30 EHSHB08P50 EHSHB16P50
BA BA BA BA BA BA
Outdoor unit ERLQ004CA ERLQ006CAV3 ERLQ008CAV3 ERLQ011CA
V3 V3
Heating capacity Min. kW 1.80 (1) / 1.81 (2) -
Nom. kW 4.26 (3) / 3.47 5.14 (3) / 4.60 (4) / 6.06 (1) / 5.53 (3) / 5.51 (4) / 7.78 (1) / 5.95 (1) / 7.74
(4) / 4.53 (1) / 5.78 (2) 7.27 (2) (2) / 11.80 (3) /
3.98 (2) 10.40 (4)
Max. kW 4.90 (1) / 5.12 8.35 (1) / 7.95 (2) 10.02 (1) / 9.53 (2) 11.38 (3) /
(2) 11.00 (4)
Power input Heating Nom. kW 0.87 (5) / 1.04 1.30 (5) / 1.58 (6) / 1.88 (3) / 1.69 (5) / 2.04 (6) / 1.98 (3) / 2.57 (5) / 3.13
(6) / 1.49 (3) / 1.26 (4) 1.56 (4) (6) / 2.43 (1) /
0.85 (4) 2.35 (2)
Max. kW 1.12 (5) / 1.44 1.99 (5) / 2.32 (6) 2.54 (5) / 2.96 (6) 2.64 (5) / 3.25
(6) (6)
COP 5.23 (5) / 3.84 4.65 (5) / 3.66 (6) / 2.73 (3) / 4.60 (5) / 3.57 (6) / 2.78 (3) / 4.38 (5) / 3.32
(6) / 2.85 (3) / 3.64 (4) 3.54 (4) (6) / 2.45 (1) /
4.07 (4) 3.29 (2)

74 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Pump Type Grundfos UPM3 25-75 CHBL
3
Nominal ESP unit Heating kPa 46.0 (7) / 48.0 40.0 (7) / 41.0 (8) 37.0 (7) / 36.0 (8) -
(8)
Water side Heat Water flow rate Heating Nom. l/min 13.0 (7) / 11.3 17.4 (7) / 16.6 (8) 22.3 (7) / 20.8 (8) 33.8 (7) / 29.8
exchanger (8) (8)
General Product description Air-to-water heat pump Yes 2
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61 62 64
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow m³/h 2,700 2,820 -
(outdoor)
Other Capacity control Inverter
Cdh (Degradation heating) 0.9
Pck (Crankcase kW 0.000
heater mode)
Poff (Off mode) kW 0.011 0.012 0.050
Psb (Standby mode) kW 0.011 0.012 0.050
Pto (Thermostat off) kW 0.043 0.048 0.105
Integrated Psup kW 9.0
supplementary Type of energy input Electrical
heater

• Heating • ERLQ-CV3 75
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General Annual kWh 2,934 3,828 4,725 6,345
water outlet 55°C energy
consumpti
on
ηs % 130 125 127 125
2 (Seasonal
space
heating
efficiency)
Prated at - kW 5 6 8 10
10°C
Seasonal space A++
heating eff. class
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 2.03 2.09 2.10 1.94
-8°CWB) Pdh kW 4.2 5.3 5.4 9.0
PERd % 81.2 83.6 84.0 77.6
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.31 3.13 3.25 3.30
1°CWB)
Pdh kW 2.6 3.1 3.9 5.4
PERd % 132.4 125.2 130.0 132.0
C Cdh (Degradation 1.0 0.9
Condition heating)
(7°CDB/ COPd 4.43 4.09 4.42 4.26
6°CWB)
Pdh kW 1.8 2.1 2.6 4.6
PERd % 177.2 163.6 176.8 170.4
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 6.55 5.99 6.30
11°CWB)
Pdh kW 2.2 2.0 5.5
PERd % 262.0 239.6 252.0
Tol COPd 1.64 1.79 1.78
(temperat Pdh kW 4.1 5.1 9.1
ure
PERd % 65.6 71.6 71.2
operating
limit) TOL °C -10
WTOL °C 55
Rated Psup (at kW 0.7 0.9 2.4 1.0
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 2.03 2.09 2.36 1.94
(bivalent Pdh kW 4.2 5.3 5.8 9.0
temperat
PERd % 81.2 83.6 94.4 77.6
ure)
Tbiv °C -7 -4 -7

76 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 3,069 4,008 4,575 8,185
3
outlet 55°C energy
consumpti
on
ηs % 109 103 109 101
(Seasonal 2
space
heating
efficiency)
Prated at - kW 4 5 9
22°C
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 2.30 2.47 2.41 1.98
-8°CWB)
Pdh kW 2.2 2.6 3.2 5.2
PERd % 92.0 98.8 96.4 79.2
B Cdh (Degradation 1.0 0.9 1.0
Condition heating)
(2°CDB/ COPd 3.75 3.26 3.69 3.25
1°CWB) Pdh kW 1.4 2.0 2.4 3.2
PERd % 150.0 130.4 147.6 130.0
C Cdh (Degradation 0.9
Condition heating)
(7°CDB/ COPd 5.92 4.42 5.58 5.50
6°CWB)
Pdh kW 1.6 2.6 3.2 5.2
PERd % 236.8 176.8 223.2 220.0
D COPd 8.65 5.54 7.79 7.56
Condition Pdh kW 1.6 3.0 3.6 6.1
(12°CDB/ PERd % 346.0 221.6 311.6 302.4
11°CWB)
Tol COPd 0.89 1.05 0.98 1.22
(temperat Pdh kW 0.8 1.0 1.2 5.7
ure PERd % 35.6 42.0 39.2 48.8
operating
TOL °C -20
limit)
WTOL °C 55
G COPd 1.25 1.42 1.33 1.51
Condition Pdh kW 2.9 3.6 4.3 7.1
(- PERd % 50.0 56.8 53.2 60.4
15°CDB/-
)
Tbiv COPd 1.25 1.42 1.33 1.51
(bivalent Pdh kW 2.9 3.6 4.3 7.1
temperat
PERd % 50.0 56.8 53.2 60.4
ure)
Tbiv °C -15
Rated Psup (at kW 3.5 4.4 5.2 3.4
heat Tdesign -
output 22°C)
suppleme
ntary
capacity

• Heating • ERLQ-CV3 77
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 1,174 1,901 1,932 2,637
outlet 55°C energy
consumpti
on
ηs % 179 145 171 146
2 (Seasonal
space
heating
efficiency)
Prated at kW 4 5 7 8
2°C
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 2.11 2.29 2.15 1.82
1°CWB)
Pdh kW 4.3 5.5 6.6 7.6
PERd % 84.4 91.6 86.0 72.8
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 3.76 3.41 3.70 3.07
6°CWB) Pdh kW 2.8 3.5 4.2 4.9
PERd % 150.4 136.4 148.0 122.8
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 7.26 4.86 6.52 5.88
11°CWB)
Pdh kW 1.6 2.9 3.5 5.4
PERd % 290.4 194.4 260.8 235.2
Tbiv COPd 2.11 2.29 2.15 1.82
(bivalent Pdh kW 4.3 5.5 6.6 7.6
temperat PERd % 84.4 91.6 86.0 72.8
ure)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Seasonal
space
heating
efficiency)
Cold climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
Qhe Gj -
Annual
energy
consumpti
on (GCV)
Warm climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)

78 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile L XL L XL
3
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual kWh 1,063 1,148 1,654 1,256 1,797 2,158
electricity
consumption) 2
ηwh (water heating % 103 98 108 90 99 84
efficiency)
Qelec (Daily electricity kWh 4.753 5.138 7.453 5.630 8.105 9.681
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual kWh 1,221 1,263 1,858 1,387 2,200 2,394
electricity
consumption)
ηwh (water heating % 92 89 95 80 76
efficiency)
Qelec (Daily electricity kWh 5.473 5.653 8.379 6.226 10.000 10.755
consumption)
Warm climate AEC (Annual kWh 948 1,068 1,510 1,138 1,696 1,921
electricity
consumption)
ηwh (water heating % 120 107 117 100 106 95
efficiency)
Qelec (Daily electricity kWh 4.229 4.763 6.796 5.091 8.000 8.600
consumption)

CONNECTABLE INDOOR UNITS


2-17 Capacity and Power input EHSHB16P50B/ERLQ014CV3 EHSHB16P50B/ERLQ016CV3
Indoor unit EHSHB16P50BA
Outdoor unit ERLQ014CAV3 ERLQ016CAV3
Heating capacity Nom. kW 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Max. kW 14.55 / 13.59 16.10 / 15.22
Power input Heating Nom. kW 3.42 / 4.07 / 3.17 / 2.93
Max. kW 3.43 / 4.22 3.83 / 4.71
COP 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
Pump Type Grundfos UPM3 25-75 CHBL
Water side Heat Water flow rate Heating Nom. l/min 42.4 / 39.4 44.0 / 42.6
exchanger
General Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 39
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 64 66
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Other Capacity control Inverter
Cdh (Degradation heating) 0.9
Pck (Crankcase heater kW 0.000
mode)
Poff (Off mode) kW 0.050
Psb (Standby mode) kW 0.050
Pto (Thermostat off) kW 0.105
Integrated Psup kW 9.0
supplementary Type of energy input Electrical
heater

• Heating • ERLQ-CV3 79
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General Annual kWh 7,654 8,978
water outlet 55°C energy
consumpti
on
ηs % 126 125
2 (Seasonal
space
heating
efficiency)
Prated at - kW 12 14
10°C
Seasonal space A++
heating eff. class
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 1.92 1.85
-8°CWB) Pdh kW 10.9 12.6
PERd % 76.8 74.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.30 3.19
1°CWB)
Pdh kW 6.6 7.8
PERd % 132.0 127.6
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 4.34 4.47
6°CWB)
Pdh kW 4.6 4.9
PERd % 173.6 178.8
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 6.45 6.52
11°CWB)
Pdh kW 5.5 5.4
PERd % 258.0 260.8
Tol COPd 1.63 1.57
(temperat Pdh kW 9.8 11.2
ure
PERd % 65.2 62.8
operating
limit) TOL °C -10
WTOL °C 55
Rated Psup (at kW 2.5 3.0
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 1.92 1.84
(bivalent Pdh kW 10.9 12.6
temperat
PERd % 76.8 73.6
ure)
Tbiv °C -7

80 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 9,676 10,405
3
outlet 55°C energy
consumpti
on
ηs % 100
(Seasonal 2
space
heating
efficiency)
Prated at - kW 10 11
22°C
A Cdh (Degradation 1.0
Condition heating)
(-7°CDB/ COPd 2.04 2.05
-8°CWB)
Pdh kW 6.2 6.6
PERd % 81.6 82.0
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 3.20 3.19
1°CWB) Pdh kW 3.8 4.0
PERd % 128.0 127.6
C Cdh (Degradation 0.9
Condition heating)
(7°CDB/ COPd 5.50
6°CWB)
Pdh kW 5.2
PERd % 220.0
D COPd 7.56
Condition Pdh kW 6.1
(12°CDB/ PERd % 302.4
11°CWB)
Tol COPd 1.13 1.08
(temperat Pdh kW 6.4 6.8
ure PERd % 45.2 43.2
operating
TOL °C -20
limit)
WTOL °C 55
G COPd 1.50 1.42
Condition Pdh kW 8.4 8.9
(- PERd % 60.0 56.8
15°CDB/-
)
Tbiv COPd 1.50 1.42
(bivalent Pdh kW 8.4 8.9
temperat
PERd % 60.0 56.8
ure)
Tbiv °C -15
Rated Psup (at kW 4.6 4.9
heat Tdesign -
output 22°C)
suppleme
ntary
capacity

• Heating • ERLQ-CV3 81
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General Annual kWh 3,282 3,429
outlet 55°C energy
consumpti
on
ηs % 144 145
2 (Seasonal
space
heating
efficiency)
Prated at kW 10
2°C
B Cdh (Degradation 1.0
Condition heating)
(2°CDB/ COPd 1.90 1.78
1°CWB)
Pdh kW 9.8 10.3
PERd % 76.0 71.2
C Cdh (Degradation 1.0
Condition heating)
(7°CDB/ COPd 3.22 3.25
6°CWB) Pdh kW 6.3 6.6
PERd % 128.8 130.0
D Cdh (Degradation 0.9
Condition heating)
(12°CDB/ COPd 5.88
11°CWB)
Pdh kW 5.4
PERd % 235.2
Tbiv COPd 1.90 1.78
(bivalent Pdh kW 9.8 10.3
temperat PERd % 76.0 71.2
ure)
Tbiv °C 2
Average climate General ηs % -
water outlet 35°C (Seasonal
space
heating
efficiency)
Cold climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
Qhe Gj -
Annual
energy
consumpti
on (GCV)
Warm climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)

82 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Domestic hot water General Declared load profile XL
3
heating Function to fix water heating Yes
during off peak hours
Average climate AEC (Annual electricity kWh 2,158
consumption)
ηwh (water heating % 84 2
efficiency)
Qelec (Daily electricity kWh 9.681
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual electricity kWh 2,394
consumption)
ηwh (water heating % 76
efficiency)
Qelec (Daily electricity kWh 10.755
consumption)
Warm climate AEC (Annual electricity kWh 1,921
consumption)
ηwh (water heating % 95
efficiency)
Qelec (Daily electricity kWh 8.600
consumption)

Notes

(1) EW 30°C; LW 35°C; ambient conditions: 7°CDB/6°CWB


(2) EW 40°C; LW 45°C; ambient conditions: 7°CDB/6°CWB
(3) EW 30°C; LW 35°C; ambient conditions: -7°CDB/-8°CWB
(4) EW 30°C; LW 35°C; ambient conditions: 2°CDB/1°CWB
(5) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(6) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(7) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(8) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

CONNECTABLE INDOOR UNITS


EHVZ04S18CB EHVZ08S18CB EHVZ08S18CB EHVZ16S18CB EHVZ16S18CB EHVZ16S18CB
3V/ 3V/ 3V/ 3V/ 3V/ 3V/
2-18 Capacity and Power input ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3
Heating capacity Min. kW 1.80 (1) -
Nom. kW 4.40 (1) / 4.03 6.00 (1) / 5.67 7.40 (1) / 6.89 11.2 (1) / 11.0 14.4 (1) / 13.5 15.9 (1) / 15.1
(2) (2) (2) (2) (2) (2)
Max. kW 5.12 (1) / 4.90 8.35 (1) / 7.95 10.0 (1) / 9.53 8.60 (3) / 8.60 10.5 (3) / 10.7 11.3 (3) / 10.8
(2) (2) (2) (4) (4) (4)
Power input Heating Nom. kW 0.870 (1) / 1.27 (1) / 1.59 1.66 (1) / 2.01 2.43 (1) / 3.10 3.39 (1) / 4.12 3.77 (1) / 4.67
1.13 (2) (2) (2) (2) (2) (2)
Max. kW - 3.13 (3) / 4.10 4.02 (3) / 5.21 4.33 (3) / 5.22
(4) (4) (4)
COP 5.04 (1) / 3.58 4.74 (1) / 3.56 4.45 (1) / 3.42 4.60 (1) / 2.75 4.24 (1) / 2.61 4.22 (1) / 2.61
(2) (2) (2) (3) / 3.55 (2) / (3) / 3.28 (2) / (3) / 3.23 (2) /
2.10 (4) 2.05 (4) 2.07 (4)
Tank Name Stainless steel domestic hot water tank 180 l
Water side Heat Water flow rate Heating Nom. l/min 12.6 (5) / 11.6 17.2 (5) / 16.3 21.2 (5) / 19.8 32.1 (1) / 31.5 41.3 (1) / 38.7 45.6 (1) / 43.3
exchanger (6) (6) (6) (1) (2) (2)

• Heating • ERLQ-CV3 83
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer details Name or trademark Daikin Europe N.V.
Product description Air-to-water heat pump Yes
Brine-to-water heat pump No
Heat pump combination heater Yes
2 Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) Sound power Indoor dB(A) 42.0 47.0
level (according to
EN14825)
LW(A) Sound power Outdoor dB(A) 61.0 62.0 64.0 66.0
level (according to
EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the
EN14825
Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,700 2,820 5,400
Brine/water to water Rated water/brine flow m³/h 0.00
unit
Other Capacity control Inverter
Cdh (Degradation heating) 1.00
Pck (Crankcase heater kW 0.00 0.055
mode)
Poff (Off mode) kW 0.0080 0.055
Psb (Standby mode) kW 0.0080 0.055
Pto (Thermostat off) kW 0.0060 0.0070 0.0080 0.057
Integrated NOx emission mg/kWh 0.00
supplementary Psup kW 3.00
heater
Type of energy input Electrical

84 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 3.20 3.22 3.23 3.09 3.16 3.06
3
water outlet 55°C Annual kWh 2,360 3,370 4,060 6,260 7,900 8,970
energy
consumpti
on
Annual Gj 8.48 12.1 14.6 22.6 28.4 32.3 2
energy
consumpti
on (GCV)
ηs % 125 126 120 123 119
(Seasonal
space
heating
efficiency)
Prated at - kW 3.70 5.30 6.40 9.99 12.7 13.9
10°C
Seasonal space A++ A+
heating eff. class
A Cdh (Degradation 1.00
Condition heating)
(-7°CDB/- COPd 2.03 2.02 1.98 1.99 1.76 1.78
8°CWB) Pdh kW 3.36 4.50 5.47 8.83 9.97 12.2
PERd % 81.2 80.8 79.2 79.6 70.4 71.2
B Cdh (Degradation 1.00 0.990 1.00
Condition heating)
(2°CDB/ COPd 3.08 3.17 3.24 3.55 3.12
1°CWB) Pdh kW 2.00 4.43 3.43 5.28 6.76 7.61
PERd % 123 127 130 142 125
C Cdh (Degradation 0.990 0.950 1.00
Condition heating)
(7°CDB/ COPd 4.27 4.20 4.31 4.22 4.40
6°CWB)
Pdh kW 2.77 3.51 3.50 4.47 4.66 4.83
PERd % 171 168 172 169 176
D Cdh (Degradation 0.990 0.930 0.940 0.930
Condition heating)
(12°CDB/ COPd 6.33 5.82 6.41 5.44 6.36
11°CWB)
Pdh kW 2.65 3.28 5.37 5.26 5.38
PERd % 253 233 256 218 254
Tol COPd 1.80 1.74 1.66 1.79 1.75 1.71
(temperat Pdh kW 3.76 4.62 6.18 9.08 12.2 13.3
ure
PERd % 72.0 69.6 66.4 71.6 70.0 68.4
operating
limit) TOL °C -10.0
WTOL °C 55.0
Rated Psup (at kW 0.00 0.680 0.220 0.910 0.550 0.580
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Tbiv COPd 1.80 1.74 1.66 1.99 1.92 1.78
(bivalent Pdh kW 3.76 5.09 6.18 8.83 11.0 12.2
temperatu
PERd % 72.0 69.6 66.4 79.6 76.8 71.2
re)
Tbiv °C -10.0 -9.00 -10.0 -7.00 -6.00 -7.00

• Heating • ERLQ-CV3 85
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Cold climate water General Annual kWh 2,130 2,310 3,090 6,740 7,870 8,580
outlet 55°C energy
consumpti
on
Annual Gj 7.68 8.30 11.1 24.3 28.3 30.9
2 energy
consumpti
on (GCV)
ηs % 107 110 95.0 95.5 98.3
(Seasonal
space
heating
efficiency)
Prated at - kW 2.39 2.60 3.56 6.99 8.15 9.12
22°C
Warm climate water General Annual kWh 1,170 1,490 1,900 2,630 3,270 3,420
outlet 55°C energy
consumpti
on
Annual Gj 4.20 5.37 6.85 9.47 11.8 12.3
energy
consumpti
on (GCV)
ηs % 186 182 178 125 135 136
(Seasonal
space
heating
efficiency)
Prated at kW 4.27 5.30 6.59 7.58 9.84 10.3
2°C

86 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Average climate General SCOP 4.52 4.29 4.34 -
3
water outlet 35°C Annual kWh 1,980 2,540 3,490 -
energy
consumpti
on
Annual Gj 7.13 9.14 12.6 - 2
energy
consumpti
on (GCV)
ηs % 178 169 171 -
(Seasonal
space
heating
efficiency)
Prated at - kW 4.40 5.34 7.40 -
10°C
Seasonal space A++ -
heating eff. class
A COPd 3.01 2.69 -
Condition Pdh kW 4.01 4.72 6.68 -
(-7°CDB/-
PERd % 120 108 -
8°CWB)
B Cdh (Degradation 1.00 0.990 1.00 -
Condition heating)
(2°CDB/ COPd 4.41 4.24 -
1°CWB) Pdh kW 2.40 3.90 -
PERd % 176 170 -
C Cdh (Degradation 0.980 1.00 -
Condition heating)
(7°CDB/ COPd 5.85 5.75 -
6°CWB) Pdh kW 1.70 2.59 -
PERd % 234 230 -
D Cdh (Degradation 0.980 -
Condition heating)
(12°CDB/ COPd 7.71 7.27 -
11°CWB)
Pdh kW 2.04 2.61 -
PERd % 308 291 -
Tol COPd 2.61 2.29 -
(temperat Pdh kW 4.36 4.70 6.81 -
ure
PERd % 104 91.6 -
operating
TOL °C -10.0 -
limit)
WTOL °C 35.0 -
Tbiv COPd 2.61 2.47 -
(bivalent Pdh kW 4.36 4.93 7.14 -
temperatu
PERd % 104 98.8 -
re)
Tbiv °C -10.0 -8.00 -
Rated Psup (at kW 0.040 0.640 0.590 -
heat Tdesign -
output 10°C)
suppleme
ntary
capacity
Cold climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
Qhe Gj -
Annual
energy
consumpti
on (GCV)

• Heating • ERLQ-CV3 87
• Outdoor Unit • ERLQ-CV3

2 Specifications

CONNECTABLE INDOOR UNITS


Space heating Warm climate water General ηs % -
outlet 35°C (Seasonal
space
heating
efficiency)
2 Pump Additional Zone Nominal ESP unit Heating kPa 52.3 (5) / 55.4 40.6 (5) / 43.3 28.3 (5) / 32.7 26.2 (1) / 28.3 25.0 (7)
(*RLQ*C*) (6) (6) (6) (2)
Pump Main Zone Nominal ESP unit Heating kPa 48.6 (5) / 51.9 39.5 (5) / 42.3 26.4 (5) / 31.2 18.2 (1) / 20.7 25.0 (7)
(*RLQ*C*) (6) (6) (6) (2)
Domestic hot water General Declared load profile L
heating Function to fix water heating during Yes
off peak hours
Average climate AEC (Annual electricity kWh 1,080 1,190 1,170
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 95.0 86.4 87.4
efficiency)
Qelec (Daily electricity kWh 4.93 5.43 5.32
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Water heating energy efficiency A
class
Cold climate AEC (Annual electricity kWh 1,220 1,330 1,340
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 84.0 77.5 76.6
efficiency)
Qelec (Daily electricity kWh 5.55 6.05 6.08
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)
Warm climate AEC (Annual electricity kWh 966 1,120 1,110
consumption)
AFC (Annual fuel Gj 0.00
consumption)
ηwh (water heating % 106 91.8 92.3
efficiency)
Qelec (Daily electricity kWh 4.39 5.10 5.04
consumption)
Qfuel (Daily fuel kWh 0.00
consumption)

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
(3) Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
(4) Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
(5) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
(6) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
(7) Capacity must be split up over the additional and main zone. Refer to ESP-data for more details on available head (kPa).

2-19 Technical Specifications ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3


Dimensions Unit HeightxWidthxDe mm 735x832x307 1,345x900x320
pth
Weight Unit kg 54 56 113
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor

88 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

2 Specifications

2-19 Technical Specifications


Operation range Cooling Min.~Max. °CDB
ERLQ004CV3 ERLQ006CV3
10.0~43.0
ERLQ008CV3 ERLQ011CV3 ERLQ014CV3
10.0~46.0
ERLQ016CV3
3
Domestic hot water Min.~Max. °CDB -25 (1)~35 (1) -20 (1)~35 (1)
Refrigerant Type R-410A
GWP 2,087.5
Charge TCO2eq 3.1 3.3 7.1
2
kg 1.5 1.6 3.4
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 (2) 66 (2)
Cooling Nom. dBA 63 64 (3) 66 (3) 69 (3)
Sound pressure level Heating Nom. dBA 48 (2) 49 (2) 51 (4) 52 (4)
Cooling Nom. dBA 48 (2) 49 (2) 50 (2) 50 (4) 52 (4) 54 (4)

2-20 Electrical Specifications ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3


Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230
Current Recommended fuses A 16 20 40
Notes

(1) Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
(2) The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to
sound spectrum drawing for more information.
(3) Daikin Altherma inverter controlled compressor starting current always \<= max. running current
(4) Contains fluorinated greenhouse gases
Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range.
Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
Condition: Ta 35°C - LWE 7°C ( DT = 5°C)

• Heating • ERLQ-CV3 89
• Outdoor Unit • ERLQ-CV3

3 Electrical data
3-1 Electrical Data

ERLQ004-008CV3
Specifications Starting current

Figure ·A· Starting current

3 Running current
[A]

Maximum running
current

Example Example
1 2

Daikin Altherma inverter-controlled compressor Time


starting current always ” max. running current.

Running
current [A]

Maximum
running current

Example Example
1 2
Time
Standard On/OFF compressor starting
current >> max. running current

4D094715A

90 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

4 Capacity tables
4-1 Cooling Capacity Tables

• Heating • ERLQ-CV3 91
• Outdoor Unit • ERLQ-CV3

4 Capacity tables
4-1 Cooling Capacity Tables

92 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

4 Capacity tables
4-2 Heating Capacity Tables

• Heating • ERLQ-CV3 93
• Outdoor Unit • ERLQ-CV3

4 Capacity tables
4-2 Heating Capacity Tables

94 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

4 Capacity tables
4-2 Heating Capacity Tables

ERLQ011-016C 3
Capacity in function of eld piping length for inverter

Capacity (%)

Cooling

Heating

Field piping length (m)

NOTE

Capacity drop is at nominal capacity


3TW60332-5A

• Heating • ERLQ-CV3 95
• Outdoor Unit • ERLQ-CV3

4 Capacity tables
4-3 Certification Programs

ERLQ004Ͳ008CV3
RateddataforcertificationprogrammesͲheatingmode

MinimumrequiredCOP

MinimumrequiredCOP

MinimumrequiredCOP

MinimumrequiredCOP

MinimumrequiredCOP

MinimumrequiredCOP

MinimumrequiredCOP
microgeneration

SPF(DAB)
Ecolabel
Vivrelec

NFPAC

EHPA

SEI
Certificationprogramme Ta[°C] EWC[°C] LWC[°C] HC[kW] COP

4
EHPA 10/8 30 35 4,47 5,12 4,00 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Créditd'impôt,NFPAC 7/6 30 35 4,40 5,04 4,00 3,40 Ͳ Ͳ Ͳ 3,20 Ͳ
Floor EHPA 2/1 35 3,27 4,02 Ͳ Ͳ 3,10 Ͳ 3,00 Ͳ Ͳ
NFPAC,EHPA Ͳ7/Ͳ8 35 4,37 2,81 2,00 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
SPF 2/1 30 35 3,27 4,02 Ͳ Ͳ Ͳ 3,10 Ͳ Ͳ 3,71
*RLQ004* NFPAC 7/6 40 45 4,03 3,58 2,50 2,70 Ͳ Ͳ Ͳ Ͳ Ͳ
Fancoil EHPA Ͳ7/Ͳ8 45 4,20 2,27 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC Ͳ7/Ͳ8 45 4,70 2,34 1,50 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 3,71 2,91 Ͳ 2,20 Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 3,74 1,80 Ͳ 1,30 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 10/8 30 35 6,25 5,07 4,00 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Créditd'impôt,NFPAC 7/6 30 35 6,00 4,74 4,00 3,40 Ͳ Ͳ Ͳ 3,20 Ͳ
Floor EHPA 2/1 35 4,58 3,66 Ͳ Ͳ 3,10 Ͳ 3,00 Ͳ Ͳ
NFPAC,EHPA Ͳ7/Ͳ8 35 5,31 2,84 2,00 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ006* SPF 2/1 30 35 4,05 3,88 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ 3,71
NFPAC 7/6 40 45 5,67 3,56 2,50 2,70 Ͳ Ͳ Ͳ Ͳ Ͳ
Fancoil
NFPAC Ͳ7/Ͳ8 45 5,12 2,22 1,50 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 5,43 2,95 Ͳ 2,20 Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 4,47 1,80 Ͳ 1,30 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 10/8 30 35 7,39 4,75 4,00 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Créditd'impôt,NFPAC 7/6 30 35 7,40 4,45 4,00 3,40 Ͳ Ͳ Ͳ 3,20 Ͳ
Floor EHPA 2/1 35 5,80 3,53 Ͳ Ͳ 3,10 Ͳ 3,00 Ͳ Ͳ
NFPAC,EHPA Ͳ7/Ͳ8 35 5,46 2,71 2,00 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ008* SPF 2/1 30 35 4,56 3,81 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ 3,71
NFPAC 7/6 40 45 6,89 3,42 2,50 2,70 Ͳ Ͳ Ͳ Ͳ Ͳ
Fancoil
NFPAC Ͳ7/Ͳ8 45 6,13 2,12 1,50 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 6,79 2,87 Ͳ 2,20 Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 5,59 1,80 Ͳ 1,30 Ͳ Ͳ Ͳ Ͳ Ͳ

RateddataforcertificationprogrammesͲstandbypowerconsumption

PI[W]
Certificationprogramme
*RLQ004* NFPAC 7,5W
*RLQ006* NFPAC 7,5W
*RLQ008* NFPAC 7,5W

Soundpowermeasurements

Requiredsetupofunit
Certificationprogramme Ta[°C] EW[°C] LW[°C] Mode dBA
fortest

EHVZ04S18CB3V Promotelec,Ecolabel,Eurovent Nominal 7/6 30 35 Heating 40

EHVZ08S18CB3V NFPAC,Ecolabel Nominal 7/6 30 35 Heating 42

Symbols

CC= Coolingcapacityatmaximumoperatingfrequency,measuredaccordingtoEN14511.
HC= Heatingcapacityatmaximumoperatingfrequency,measuredaccordingtoEN14511
COP/EER= CoefficientofPerformance/EnergyefficiencyratioaccordingtoEN14511.
LWE= Leavingwaterevaporatortemperature[°C]
LWC= Leavingwatercondensortemperature[°C]
Ta= Ambienttemperature[°CDB/WB]
3D096433

ERLQ004-008CV3
Rated data for certification programmes - heating mode
Minimum required COP

Minimum required COP

Minimum required COP

Minimum required COP

Minimum required COP

Minimum required COP

Minimum required COP


microgeneration

SPF (DAB)
Ecolabel
Vivrelec

NF PAC

EHPA

SEI

Certification programme Ta [°C] EWC [°C] LWC [°C] HC [kW] COP

EHPA 10/8 30 35 4,47 5,12 4,00 - - - - - -


Crédit d'impôt, NF PAC, Microgeneration 7/6 30 35 4,40 5,04 4,00 3,40 - - - 3,20 -
Floor EHPA, SEI 2/1 35 3,27 4,02 - - 3,10 - 3,00 - -
NF PAC, EHPA -7/-8 35 4,37 2,81 2,00 2,10 - - - - -
Ecolabel, SPF 2/1 30 35 3,27 4,02 - - - 3,10 - - 3,71
NF PAC 7/6 40 45 4,03 3,58 2,50 2,70 - - - - -
*RLQ004* EHPA -7/-8 45 4,20 2,27 - - - - - - -
Fan coil
NF PAC -7/-8 45 4,70 2,34 1,50 1,60 - - - - -
Ecolabel 2/1 40 45 3,97 2,77 1,50 - - 2,60 - - -
Danish incentive (< 2013) 2/1 50 55 3,93 2,43 - - - - - - -
Danish incentive (< 2013) -7/-8 50 55 4,20 1,98 - - - - - - -
Radiator
EHPA 7/6 47 55 3,71 2,91 - 2,20 - - - - -
EHPA -7/-8 55 3,74 1,80 - 1,30 - - - - -
EHPA 10/8 30 35 6,25 5,07 4,00 - - - - - -
Crédit d'impôt, NF PAC, Microgeneration 7/6 30 35 6,00 4,74 4,00 3,40 - - - 3,20 -
EHPA, SEI 2/1 35 4,58 3,66 - - 3,10 - 3,00 - -
Floor
NF PAC, EHPA -7/-8 35 5,31 2,84 2,00 2,10 - - - - -
Ecolabel 2/1 30 35 4,58 3,66 - - - 3,10 - - -
SPF 2/1 30 35 4,05 3,88 - - - - - - 3,71
*RLQ006* NF PAC 7/6 40 45 5,67 3,56 2,50 2,70 - - - - -
Fan coil NF PAC -7/-8 45 5,12 2,22 1,50 1,60 - - - - -
Ecolabel 2/1 40 45 5,69 2,81 1,50 - 2,60 -
Danish incentive (< 2013) 2/1 50 55 5,27 2,29 - - - - - - -
Danish incentive (< 2013) -7/-8 50 55 4,96 1,86 - - - - - - -
Radiator
EHPA 7/6 47 55 5,43 2,95 - 2,20 - - - - -
EHPA -7/-8 55 4,47 1,80 - 1,30 - - - - -
EHPA 10/8 30 35 7,39 4,75 4,00 - - - - - -
Crédit d'impôt, NF PAC, Microgeneration 7/6 30 35 7,40 4,45 4,00 3,40 - - - 3,20 -
EHPA, SEI 2/1 35 5,80 3,53 - - 3,10 - 3,00 - -
Floor
NF PAC, EHPA -7/-8 35 5,46 2,71 2,00 2,10 - - - - -
Ecolabel 2/1 30 35 5,80 3,53 - - - 3,10 - - -
SPF 2/1 30 35 4,56 3,81 - - - - - - 3,71
*RLQ008* NF PAC 7/6 40 45 6,89 3,42 2,50 2,70 - - - - -
Fan coil NF PAC -7/-8 45 6,13 2,12 1,50 1,60 - - - - -
Ecolabel 2/1 40 45 6,08 2,63 - - 2,60 - - -
Danish incentive (< 2013) 2/1 50 55 5,45 2,27 - - - - - - -
Danish incentive (< 2013) -7/-8 50 55 5,50 1,86 - - - - - - -
Radiator
EHPA 7/6 47 55 6,79 2,87 - 2,20 - - - - -
EHPA -7/-8 55 5,40 1,80 - 1,30 - - - - -

Rated data for certification programmes - cooling mode


Minimum required

Minimum required
Vivrelec

Italy D1
EER

EER

Certification programme Ta [°C] EWC [°C] LWC [°C] CC [kW] EER

*RLQ004* Floor Ecolabel, Italy D1 35 23 18 4,08 4,55 2,20 3,60 - - - -


Fan coil Ecolabel 35 12 7 4,17 2,32 2,20 - - - - -
*RLQ006* Floor Ecolabel, Italy D1 35 23 18 5,88 3,89 2,20 3,60 - - - -
Fan coil Ecolabel 35 12 7 4,84 2,34 2,20 - - - - -
*RLQ008* Floor Ecolabel, Italy D1 35 23 18 6,20 3,79 2,20 3,60 - - - -
Fan coil Ecolabel 35 12 7 5,36 2,29 2,20 - - - - -
Minimum required
COP

DEA

Rated data for certification programmes - standby power consumption Rated data for certification programmes - heating mode
Certification programme sCOP
PI [W]
Certification programme Danish energy agency Average climate - low temperature (35°C) 4,52 3,5
*RLQ004*
*RLQ004* NF PAC 7,5W Danish energy agency Average climate - high temperature( 55°C) 3,2 3
*RLQ006* NF PAC 7,5W Danish energy agency Average climate - low temperature (35°C) 4,29 3,5
*RLQ006* Danish energy agency 3,22 3
*RLQ008* NF PAC 7,5W Average climate - high temperature( 55°C)
Danish energy agency Average climate - low temperature (35°C) 4,34 3,5
*RLQ008*
Sound power measurements Danish energy agency Average climate - high temperature( 55°C) 3,2 3

Required setup of
Certification programme Ta [°C] EW [°C] LW [°C] Mode dBA
unit for test

EHB(H/X)(04/08)* 40
Promotelec, Ecolabel, Eurovent Nominal 35 12 7 Cooling
EHV(H/X)(04/08)* 42

EHB(H/X)(04/08)* 40
NF PAC, Ecolabel Nominal 7/6 30 35 Heating
EHV(H/X/Z)(04/08)* 42

Symbols
CC= Cooling capacity at maximum operating frequency, measured according to EN 14511.
HC= Heating capacity at maximum operating frequency, measured according to EN 14511
COP/EER= Coefficient of Performance/Energy efficiency ratio according to EN 14511.
LWE= Leaving water evaporator temperature [°C]
LWC= Leaving water condensor temperature [°C]
Ta= Ambient temperature [°C DB/WB]
sCOP = Seasonal coefficient of performance, according to EN14825 and EN14511
3TW60819-3G

96 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

4 Capacity tables
4-3 Certification Programs

3
ERLQ011Ͳ016CV3
RateddataforcertificationprogrammesͲheatingmode

Minimumrequired

Minimumrequired

Minimumrequired

Minimumrequired

SPF(DAB)
Ecolabel
NFPAC

EHPA
HC[kW] COP

COP

COP

COP

COP
4
Certificationprogramme Ta[°C] EWC[°C] LWC[°C]

EHPA 10 35 11,20 4,85 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ


NFPAC,EHPA 7/6 30 35 11,20 4,60 3,40 Ͳ Ͳ Ͳ Ͳ Ͳ
Floor EHPA 2/1 35 8,56 3,60 Ͳ 3,10 Ͳ Ͳ Ͳ
SPF(DAB) 2/1 30 35 5,71 3,71 Ͳ Ͳ Ͳ 3,71 Ͳ Ͳ
NFPAC,EHPA Ͳ7/Ͳ8 35 8,60 2,75 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ011C* Ͳ Ͳ Ͳ
NFPAC 7/6 40 45 11,00 3,55 2,70 Ͳ Ͳ
Fancoil 2/1 45 8,20 2,84 Ͳ Ͳ 2,60 Ͳ Ͳ Ͳ
NFPAC Ͳ7/Ͳ8 45 8,60 2,10 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 10,76 2,71 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 8,79 1,74 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 10 35 14,30 4,70 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC,EHPA 7/6 30 35 14,40 4,24 3,40 Ͳ Ͳ Ͳ Ͳ Ͳ
Floor EHPA 2/1 35 10,20 3,35 Ͳ 3,10 Ͳ Ͳ Ͳ
SPF(DAB) 2/1 30 35 5,71 3,71 Ͳ Ͳ Ͳ 3,71 Ͳ Ͳ
NFPAC,EHPA Ͳ7/Ͳ8 35 10,50 2,61 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ014C* Ͳ Ͳ Ͳ
NFPAC 7/6 40 45 13,50 3,28 2,70 Ͳ Ͳ
Fancoil 2/1 45 9,90 2,63 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC Ͳ7/Ͳ8 45 10,70 2,05 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 13,30 2,71 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 10,83 1,74 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 10 35 15,70 4,50 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC,EHPA 7/6 30 35 15,90 4,22 3,40 Ͳ Ͳ Ͳ Ͳ Ͳ
Floor EHPA 2/1 35 10,90 3,31 Ͳ 3,10 Ͳ Ͳ Ͳ Ͳ
SPF(DAB) 2/1 30 35 5,71 3,71 Ͳ Ͳ Ͳ 3,71 Ͳ Ͳ
NFPAC Ͳ7/Ͳ8 35 11,30 2,61 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ016C* Ͳ Ͳ Ͳ
NFPAC 7/6 40 45 15,10 3,23 2,70 Ͳ Ͳ
Fancoil 2/1 45 10,80 2,63 Ͳ Ͳ 2,60 Ͳ Ͳ Ͳ
NFPAC Ͳ7/Ͳ8 45 10,80 2,07 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 15,04 2,80 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 10,79 1,71 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ

RateddataforcertificationprogrammesͲstandbypowerconsumption
Certificationprogramme
*RLQ011C*V3 NFPAC 22W
*RLQ011C*W1 NFPAC 25W
*RLQ014C*V3 NFPAC 22W
*RLQ014C*W1 NFPAC 25W
*RLQ016C*V3 NFPAC 22W
*RLQ016C*W1 NFPAC 25W

Symbols

CC= Coolingcapacityatnominaloperatingfrequency,measuredaccordingtoEN14511.
HC= Heatingcapacityatnominaloperatingfrequency,measuredaccordingtoEN14511.
COP/EER= CoefficientofPerformance/EnergyefficiencyratioaccordingtoEN14511.
LWE= Leavingwaterevaporatortemperature[°C]
LWC= Leavingwatercondensortemperature[°C] 3D091994
Ta= Ambienttemperature[°CDB/WB]

ERLQ011Ͳ016CV3

RateddataforcertificationprogrammesͲheatingmode
MinimumrequiredCOP

MinimumrequiredCOP

MinimumrequiredCOP

MinimumrequiredCOP

SPF(DAB)
Ecolabel
NFPAC

EHPA

HC[kW] COP
Certificationprogramme Ta[°C] EWC[°C] LWC[°C]

EHPA 10 35 11,20 4,85 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ


NFPAC,EHPA 7/6 30 35 11,20 4,60 3,40 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 2/1 35 8,56 3,60 Ͳ 3,10 Ͳ Ͳ Ͳ
Floor
Ecolabel 2/1 30 35 8,56 3,60 Ͳ Ͳ 3,10 Ͳ Ͳ Ͳ
SPF(DAB) 2/1 30 35 5,71 3,71 Ͳ Ͳ Ͳ 3,71 Ͳ Ͳ
NFPAC,EHPA,Piemonte(Italy) Ͳ7/Ͳ8 35 8,60 2,75 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ011C*
NFPAC 7/6 40 45 11,00 3,55 2,70 Ͳ Ͳ Ͳ Ͳ Ͳ
2/1 45 8,20 2,84 Ͳ Ͳ 2,60 Ͳ Ͳ Ͳ
Fancoil
NFPAC Ͳ7/Ͳ8 45 8,60 2,10 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
Ecolabel 2/1 40 45 8,20 2,80 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 10,76 2,71 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 8,79 1,74 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 10 35 14,30 4,70 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC,EHPA 7/6 30 35 14,50 4,30 3,40 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 2/1 35 10,30 3,41 Ͳ 3,10 Ͳ Ͳ Ͳ
Floor Ecolabel 2/1 30 35 10,30 3,41 Ͳ Ͳ 3,10 Ͳ Ͳ Ͳ
SPF(DAB) 2/1 30 35 5,71 3,71 Ͳ Ͳ Ͳ 3,71 Ͳ Ͳ
NFPAC,EHPA Ͳ7/Ͳ8 35 10,60 2,65 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ014C* Piemonte(Italy) Ͳ7/Ͳ8 35 8,60 2,75 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC 7/6 40 45 13,60 3,32 2,70 Ͳ Ͳ Ͳ Ͳ Ͳ
2/1 45 10,00 2,67 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Fancoil
NFPAC Ͳ7/Ͳ8 45 10,80 2,08 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
Ecolabel 2/1 40 45 10,00 2,70 Ͳ Ͳ 2,60 Ͳ Ͳ Ͳ
EHPA 7/6 47 55 13,30 2,71 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 10,83 1,74 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 10 35 15,70 4,50 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC,EHPA 7/6 30 35 16,00 4,25 3,40 Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 2/1 35 11,10 3,35 Ͳ 3,10 Ͳ Ͳ Ͳ Ͳ
Floor Ecolabel 2/1 30 35 11,10 3,35 Ͳ Ͳ 3,10 Ͳ Ͳ Ͳ
SPF(DAB) 2/1 30 35 5,71 3,71 Ͳ Ͳ Ͳ 3,71 Ͳ Ͳ
NFPAC Ͳ7/Ͳ8 35 11,40 2,64 2,10 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ016C* Piemonte(Italy) Ͳ7/Ͳ8 35 8,60 2,75 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
NFPAC 7/6 40 45 15,20 3,26 2,70 Ͳ Ͳ Ͳ Ͳ Ͳ
2/1 45 10,90 2,63 Ͳ Ͳ 2,60 Ͳ Ͳ Ͳ
Fancoil
NFPAC Ͳ7/Ͳ8 45 10,90 2,09 1,60 Ͳ Ͳ Ͳ Ͳ Ͳ
Ecolabel 2/1 40 45 10,90 2,66 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
EHPA 7/6 47 55 15,04 2,80 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Radiator
EHPA Ͳ7/Ͳ8 55 10,79 1,71 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ

RateddataforcertificationprogrammesͲcoolingmode
Minimumrequired

Minimumrequired
Ecolabel

ItalyD1
EER

EER

Certificationprogramme Ta[°C] EWC[°C] LWC[°C] CC[kW] EER

Floor Ecolabel,ItalyD1 35 23 18 12,13 3,98 2,20 3,60 Ͳ Ͳ Ͳ Ͳ Ͳ


*RLQ011C*
Fancoil Ecolabel 35 12 7 11,72 2,72 2,20 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Floor Ecolabel,ItalyD1 35 23 18 12,72 3,96 2,20 3,60 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ014C*
Fancoil Ecolabel 35 12 7 12,55 2,47 2,20 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ
Floor Ecolabel,ItalyD1 35 23 18 13,79 3,69 2,20 3,60 Ͳ Ͳ Ͳ Ͳ Ͳ
*RLQ016C*
Fancoil Ecolabel 35 12 7 13,12 2,29 2,20 Ͳ Ͳ Ͳ Ͳ Ͳ Ͳ

RateddataforcertificationprogrammesͲstandbypowerconsumption

Certificationprogramme
*RLQ011C*V3 NFPAC 22W
*RLQ011C*W1 NFPAC 25W
*RLQ014C*V3 NFPAC 22W
*RLQ014C*W1 NFPAC 25W
*RLQ016C*V3 NFPAC 22W
*RLQ016C*W1 NFPAC 25W

Symbols
CC= Coolingcapacityatnominaloperatingfrequency,measuredaccordingtoEN14511.
HC= Heatingcapacityatnominaloperatingfrequency,measuredaccordingtoEN14511.
COP/EER= CoefficientofPerformance/EnergyefficiencyratioaccordingtoEN14511.
LWE= Leavingwaterevaporatortemperature[°C]
LWC= Leavingwatercondensortemperature[°C]
Ta= Ambienttemperature[°CDB/WB]
3TW60332Ͳ3F

• Heating • ERLQ-CV3 97
• Outdoor Unit • ERLQ-CV3

5 Dimensional drawings
5-1 Dimensional Drawings

ERLQ011-016CV3

Hole for anchor 1 Gas pipe connection Ø15.9 are


2 Liquid connection pipe Ø9.5 flare
3 Service port (in the unit)
4 Electronic connection and grounding terminal M5 (in switchbox)
5 Refrigerant piping intake
6 Power supply wiring intake (knock hole Ø34)
7 Control wiring intake (knock hole Ø27)
8 Drain outlet

3TW60334-2

98 • Heating • ERLQ-CV3
• Outdoor Unit • ERLQ-CV3

6 Centre of gravity
6-1 Centre of Gravity

ERLQ011-016CV3

4TW31729-4

• Heating • ERLQ-CV3 99
• Outdoor Unit • ERLQ-CV3

7 Piping diagrams
7-1 Piping Diagrams

100 • Heating • ERLQ-CV3


• Outdoor Unit • ERLQ-CV3

8 Wiring diagrams
8-1 Wiring Diagrams - Single Phase

3


• Heating • ERLQ-CV3 101


• Outdoor Unit • ERLQ-CV3

8 Wiring diagrams
8-1 Wiring Diagrams - Single Phase

ERLQ011-016CV3

8
1N~50Hz
230V Indoor

Outdoor

(Note 4)

Position of
compressor
terminal

Wire entrance

El. compo. assy. A1P Printed circuit board (main) K2R Magnetic relay (Y3S) R5T Thermistor (heat exchanger middle)
(position of elements)
A2P Printed circuit board (service) K3R Magnetic relay (E1H) R6T Thermistor (liquid)
A3P Printed circuit board (noise lter) K4R Magnetic relay (E1HC) RC Signal receiver circuit
A4P Printed circuit board (communication) K10R Magnetic relay (upload) R10T Thermistor (fin)
BS1~BS4 Push button switch K11R Magnetic relay (main) S1NPH Pressure sensor
HAP
C1~C4 Capacitor L1R Reactor S1PH Pressure switch (high)
DS1 Dip switch M1C Motor (compressor) TC Signal transmission circuit
A1P
(Back) (Front) E1H Bottomplate heater M1F Motor (fan) (upper) V1R Power module
E1HC Crankcase heater M2F Motor (fan) (lower) V2R,V3R Diode module
F1U,F3U,F4U Fuse (T 3.6A / 250V) PS Swtiching power supply V1T IGBT
F6U Fuse (T 5.0A / 250V) Q1DI Earth leakage circuit breaker X1M Terminal strip (power supply)
F7U,F8U Fuse (F 1.0A / 250V) R1 Resistor Y1E Electronic expansion valve (main)
Light emit. diode (serv. monitor-orange) R2 Resistor Y3E Electronic expansion valve (inj)
H1P~7P
(A2P) [H2P] Pepare, test ............................ ickering R1T Thermistor (air) Y1S Solenoid valve (4 way valve)
Malfunction detection..................light up R2T Thermistor (discharge) Y3S Solenoid valve (hot gas pass)
HAP Light emitting diode R3T Thermistor (suction) Z1C~Z3C Noise filter (ferrity core)
(A1P) (Service monitor green) R4T Thermistor (heat exchanger) Z1F~Z4F Noise filter
K1R Magnetic relay (Y1S)

2TW60336-2
NOTES

1. This wiring diagram only applies to the outdoor unit


2. L: live, N: neutral, : eld wiring
3. : terminal strip, : connector, : connection, : protective earth (screw), : connector, : noiseless earth, : terminal
4. Refer to the option manual, for connecting wiring to X6A.
5. Refer to the ‘wiring diagram sticker’ (on back of front plate) on how to use BS1~BS4 and DS1 switch
6. Do not operate the unit by short-circuiting protection device S1PH
7. Colors: = blue, = brown, = green, = red, = white, = yellow, = orange, = black
8. Conrm the method of setting the selector switches (DS1) by service manual; Factory setting of all switches: “off”
9. : option, : wiring dependent on model

102 • Heating • ERLQ-CV3


• Outdoor Unit • ERLQ-CV3

9 Sound data
9-1 Sound Power Spectrum Quiet Mode

3
Cooling
Sound pressure level (dB)

Sound pressure level (dB)

Sound pressure level (dB)


9

Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz)

NOTES

1 Data is valid at free field condition (measured in a semi-anachoic room). Measuring location (discharge side):
2 dBA = A-weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20—Pa.
4 If the sound is measured under actual installation conditions, the measured value will be
higher due to environmental noise and sound reflections.
5 Data is valid at night quiet mode level 2

3TW60337-3

Heating
Sound pressure level (dB)

Sound pressure level (dB)

Sound pressure level (dB)

Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz)

NOTES

1 Data is valid at free field condition (measured in a semi-anachoic room). Measuring location (discharge side):
2 dBA = A-weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20—Pa.
4 If the sound is measured under actual installation conditions, the measured value will be
higher due to environmental noise and sound reflections.
5 Data is valid at night quiet mode level 2

3TW60337-4

• Heating • ERLQ-CV3 103


• Outdoor Unit • ERLQ-CV3

9 Sound data
9-2 Sound Pressure Spectrum - Cooling

104 • Heating • ERLQ-CV3


• Outdoor Unit • ERLQ-CV3

9 Sound data
9-2 Sound Pressure Spectrum - Cooling

3
Cooling
Sound pressure level (dB)

Sound pressure level (dB)

Sound pressure level (dB)


9

Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz)

NOTES

1 Data is valid at free field condition (measured in a semi-anachoic room). Measuring location (discharge side):
2 dBA = A-weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20—Pa.
4 If the sound is measured under actual installation conditions, the measured value will be
higher due to environmental noise and sound reflections.
5 Data is valid at nominal capacity

3TW60337-1

• Heating • ERLQ-CV3 105


• Outdoor Unit • ERLQ-CV3

9 Sound data
9-3 Sound Pressure Spectrum - Heating

Heating
Sound pressure level (dB)

Sound pressure level (dB)

Sound pressure level (dB)


9

Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz)

NOTES

1 Data is valid at free field condition (measured in a semi-anachoic room). Measuring location (discharge side):
2 dBA = A-weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20—Pa.
4 If the sound is measured under actual installation conditions, the measured value will be
higher due to environmental noise and sound reflections.
5 Data is valid at nominal capacity

3TW60337-2

ERLQ004-008CV3
Heating

ERLQ004CA* ERLQ006CA* ERLQ008CA*


70 70 70 70 70 70
NR75 NR75 NR75
65 65 65
NR70 NR70 NR70

60 60 60 60 60 60
NR65 NR65 NR65

55 55 55
NR60 NR60 NR60
50 50 50 50 50 50
NR55
Sound pressure level [dB]
Sound pressure level [dB]

NR55 NR55
Sound pressure level [dB]

45 45 45
NR50 NR50 NR50

40 40 40 40 40 40
NR45 NR45 NR45
35 35 35
NR40 NR40 NR40
30 NR35 30 30 NR35 30 30 NR35 30

25 NR30 25 NR30 25 NR30

20 NR25 20 20 NR25 20 20 NR25 20

15 NR20 15 NR20 15 NR20


NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
Octave band centre frequency [Hz] Octave band centre frequency [Hz] Octave band centre frequency [Hz]

3,28Ft
(1m)
(1,5m)
4,92Ft

Notes
1. Data is valid at free field condition.
Measured in a semi-anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A-weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 μPa
5. If the sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and
sound reflections.

3TW60817-2B

106 • Heating • ERLQ-CV3


• Outdoor Unit • ERLQ-CV3

10 Installation
10 - 1 Installation Method

ERLQ011-016C 3
Installation servicing space
Ó Ò Ô Ñ Ð A B1 B2 C D1 D2 E L1/L2
3 •200
3 3 3 •200 •200 •200 10
3 3 •200 •500 •1000
3 3 3 3 •300 •300 •300 •500 •1000 1
3 •500
3 3 •500 •500 •1000
L1<L2 •200 •500
3 3 L2<L1 •200 •500
•750 0<L1”1/2H
L1”H •350 •500 •1000
L1<L2 •1000 0<L1”1/2H
H<L1 L1”H
3 3 3 •200 0<L2”1/2H 2
L2”H •1000 •500 •1000
L2<L1 •300 1/2H<L2”H
H<L2 L2”H

NOTES
Legend (Unit: mm)
Ó Suction side obstacle
Ò Discharge side obstacle
Ô Left side obstacle
Ñ Right side obstacle
Ð Top side obstacle
3Obstacle is present
This situation is not allowed
1 Recommended installation set-up for the ERLQ011~016*
(to prevent exposure to wind or that the heat exchanger coil is affected by snow)

2 In these cases, close bottom of the installation frame to prevent discharged air from being bypassed

3TW60339-1

• Heating • ERLQ-CV3 107


• Outdoor Unit • ERLQ-CV3

10 Installation
10 - 1 Installation Method

ERLQ011-016C

Installation guidelines / precautions Daikin Altherma


Outdoor unit
Installation location (general)
10 Select an installation site that meets the following requirements:
• The foundation must be strong enough to support the weight of the unit. The floor is flat to prevent vibrations and noise
generation and to have sufficient stability.
• The space around the unit is adequate for maintenance/servicing and allows for sufficient air circulation.(Refer to “Installation
and service space” information sheet}
• There is no danger of fire due to leakage of inflammable gas.
• The equipment is not intended for use in a potentially explosive atmosphere.
• Select the location of the unit in such a way that the sound and discharged cold/hot air generated by the unit does not disturb
anyone, and the location is selected according the applicable legislation.
• All piping lengths and distances have been taken into consideration (refer to “Technical specification” information sheet).
• Take care that in the event of a water leak, water cannot cause any damage to the installation space and surroundings.
• Install units, power cords and inter-unit cables at least 3 m away from television and radio sets. This is to prevent
interference to images and sounds.
• Depending on radio wave conditions, electromagnetic interference may still occur even if installed more than 3 m away.

Do not install in the following locations:


• Locations where sulphurous acids and other corrosive gases may be present in the atmosphere.
• Locations where a mineral oil mist, spray or vapour may be present in the atmosphere.
• Locations where flammable gases may leak, where thinner, gasoline and other volatile substances are handled, or where
carbon dust and other incendiary substances are found in the atmosphere.
• In areas where the air contains high levels of salt such as that near the ocean.
• To prevent exposure to wind, install the outdoor unit with its suction side facing the wall.
• Never install the outdoor unit at a site where the suction side (left and back) may be exposed directly to wind, snow. (See
“Installation and Service space” information sheet and figure 1)

Installation location (in cold climates)


• To prevent exposure to wind, install a baffle plate on the air discharge side of the outdoor unit.
• Unit should be installed in a way that a minimum of 10 cm free space is assured below the unit’s bottom plate at all
conditions (prevent burying in snow), e.g.: heavy snowfall (if necessary construct a pedestal).
• In heavy snowfall areas it is very important to select an installation site where the snow will not affect the unit. Make sure that
the heat exchanger coil (left and back side) is not affected by the snow (if necessary construct a lateral canopy and baffle
plate on the air side).
• Recommended installation set-up. (See “Installation and Service space” information sheet and figure 2)

Figure 1: construction to Figure 2: construction to


prevent exposure to wind and prevent affect of snow to the
snow unit

4TW60339-2

108 • Heating • ERLQ-CV3


• Outdoor Unit • ERLQ-CV3

11 Operation range
11 - 1 Operation Range

(5/4&9 3
2XWGRRUWHPSHUDWXUH>r&'%@ ,QGRRU


$$VHULHV
$%VHULHV
&RROLQJPRGH

1RWDSSOLFDEOHIRU(+9= PRGHOV
SKDVHSKDVH
aN:FODVV

%$VHULHV 2XWGRRUWHPSHUDWXUH>r&'%@
%%VHULHV



&$VHULHV

&RROLQJPRGH
1RWDSSOLFDEOHIRU& 9)PRGHOV
&%VHULHV

SKDVH&VHULHV
aN:FODVV
 1RWDSSOLFDEOHIRU(+9= PRGHOV

11
(+9= ,QWHJUDWHG%L]RQH


 
/HDYLQJZDWHUHYDSRUDWRUWHPSHUDWXUH>r&@ 

2XWGRRUWHPSHUDWXUH>r&'%@    
/HDYLQJZDWHUHYDSRUDWRUWHPSHUDWXUH>r&@
 2XWGRRUWHPSHUDWXUH>r&'%@ 2XWGRRUWHPSHUDWXUH>r&'%@

 

+HDWLQJPRGH


SKDVH&VHULHV
SKDVHSKDVH&VHULHV

SKDVH%VHULHV

+HDWLQJPRGH
aN:FODVV
+HDWLQJPRGH

aN:FODVV

SKDVH%VHULHV
aN:FODVV



  ,QGRRU
  &$VHULHV

&%VHULHV

& 9)VHULHV

        (+9= ,QWHJUDWHG%L]RQH
/HDYLQJZDWHUFRQGHQVRUWHPSHUDWXUH>r&@

         
/HDYLQJZDWHUFRQGHQVRUWHPSHUDWXUH>r&@ /HDYLQJZDWHUFRQGHQVRUWHPSHUDWXUH>r&@

/HJHQG
%DFNXSKHDWHURQO\RSHUDWLRQ
1RRXWGRRUXQLWRSHUDWLRQ

2XWGRRUXQLWRSHUDWLRQLIVHWSRLQWุr&

2SHUDWLRQRIRXWGRRUXQLWSRVVLEOHEXWZLWKSRVVLEOHFDSDFLW\UHGXFWLRQ
,IWKHRXWGRRUWHPSHUDWXUHದr&WKHRXWGRRUXQLWZLOOVWRS
,QGRRUXQLWDQGEDFNXSKHDWHURSHUDWLRQZLOOFRQWLQXH

3XOOGRZQDUHD

5HPDUN
,QUHVWULFWHGSRZHUVXSSO\PRGHWKHRXWGRRUXQLWERRVWHUKHDWHUDQGEDFNXSKHDWHUFDQRQO\RSHUDWHVHSDUDWHO\

5/4XQLWVLQFOXGHVSHFLDOHTXLSPHQW LQVXODWLRQKHDWHUVKHHW WRHQVXUHSURSHURSHUDWLRQLQDUHDVZLWKORZDPELHQWWHPSHUDWXUHVDQGKLJKKXPLGLW\FRQGLWLRQV


,QVXFKFRQGLWLRQVWKH 5+4PRGHOVPD\H[SHULHQFHSUREOHPVZLWKVHYHUHLFHEXLOGXSRQWKHDLUFRROHGFRLO
,IVXFKFRQGLWLRQVDUHH[SHFWHGWKH 5/4PXVWEHLQVWDOOHGLQVWHDG
7KHVHPRGHOVFRQWDLQFRXQWHUPHDVXUHV LQVXODWLRQKHDWHUVKHHW WRSUHYHQWIUHH]HXS

7:)
(5/4&9

2XWGRRUWHPSHUDWXUH>r&'%@
2XWGRRUWHPSHUDWXUH>r&'%@
'RPHVWLFKRWZDWHUKHDWLQJPRGH

 2XWGRRUWHPSHUDWXUH>r&'%@

'RPHVWLFKRWZDWHUKHDWLQJPRGH
SKDVHSKDVH&VHULHV


SKDVH%VHULHV
aN:FODVV

aN:FODVV



'RPHVWLFKRWZDWHUKHDWLQJPRGH


SKDVH&VHULHV
N:FODVV



 

     
'RPHVWLFKRWZDWHUWDQNWHPSHUDWXUH> r&@     
'RPHVWLFKRWZDWHUWDQNWHPSHUDWXUH> r&@       
2XWGRRUWHPSHUDWXUH>r&'%@
'RPHVWLFKRWZDWHUWDQNWHPSHUDWXUH> r&@
2XWGRRUWHPSHUDWXUH>r&'%@ 2XWGRRUWHPSHUDWXUH>r&'%@


'RPHVWLFKRWZDWHUKHDWLQJPRGH


'RPHVWLFKRWZDWHUKHDWLQJPRGH


'RPHVWLFKRWZDWHUKHDWLQJPRGH
SKDVHSKDVH&VHULHV


SKDVH&VHULHV
aN:FODVV
SKDVH%VHULHV
aN:FODVV


aN:FODVV






  
      
          
'RPHVWLFKRWZDWHUWDQNWHPSHUDWXUH> r&@
'RPHVWLFKRWZDWHUWDQNWHPSHUDWXUH> r&@ 'RPHVWLFKRWZDWHUWDQNWHPSHUDWXUH> r&@

/HJHQG
2QO\ERRVWHUKHDWHURSHUDWLRQ(.+:

2QO\EDFNXSKHDWHURSHUDWLRQ(.+9 %% (.+76 (+9 &$

2QO\ERRVWHUKHDWHURSHUDWLRQ(.+:
2QO\EDFNXSKHDWHURSHUDWLRQ(.+9 %% (.+76 (+9 &$

2SHUDWLRQRIRXWGRRUXQLWSRVVLEOHEXWZLWKSRVVLEOHFDSDFLW\UHGXFWLRQ
,IWKHRXWGRRUWHPSHUDWXUHದr&WKHRXWGRRUXQLWZLOOVWRS
,QGRRUXQLWDQGEDFNXSKHDWHURSHUDWLRQZLOOFRQWLQXH

5HPDUN
,QUHVWULFWHGSRZHUVXSSO\PRGH (.+: RQO\ WKHRXWGRRUXQLWERRVWHUKHDWHUDQGEDFNXSKHDWHUFDQRQO\RSHUDWHVHSDUDWHO\

7:(

• Heating • ERLQ-CV3 109


Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
Daikin Europe N.V. participates in the Eurovent Certifica-
tion programme for Liquid Chilling Packages (LCP), Air
handling units (AHU), Fan coil units (FCU) and variable
refrigerant flow systems (VRF) Check ongoing validity of
certificate online: www.eurovent-certification.com or us-
ing: www.certiflash.com
EEDEN 09/16
The present leaflet is drawn up by way of information only and does not constitute an offer binding
upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its
knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fit-
ness for particular purpose of its content and the products and services presented therein. Specifica-
tions are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the use and/or inter-
pretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

S-ar putea să vă placă și