(h) Total Area of Compressive Reinforcement in mm ( 3216.99 + 3216.99 ) 6433.98
2
(i) Area of Chimney (or Concrete) (Ac) in mm ( ( 1000 * 0.85) ^2 ) -6433.98 7.16E+05
(j) Percentage of Compressive reinforcement (p) p = ( 100 * 6433.98 / ((0.85 * 0.85 ) * 1000 ^ 2 ) 0.891
p/fck 0.045
As per Clause 39.6 of IS 456 -2000 Ultimate
(k) Puz = ( 0.45 * 20 * 716066 + 0.75 * 500 * 6433.98 ) 8857337
Axial Load (Puz) in N is given by
(l) Ratio between Load Pu and Puz (Pu/Puz) ( 2689902 / 8857337 ) 0.304
Where :-'Mux and Muy are moments about Mux1& Muy1are uniaxial moment capacity for an axial load of Pu, Bending about
(n)
X and Y Axes due to Design Loads X and Yaxes respectively to be obtained from SP-16
" n " is the constant depends on ( Pu/Puz ) value (* *) For Pu/Puz = <0.20 " n " = 1.0
For Pu/Puz = 0.2 to 0.80 " n" Varies linearly from 1.00 to 2.00
(* * ) (Refer Page No 71 of IS 456 - 2000 )
(o) Ratio between Effective cover / Breadth of Chimney (50 + 32 / 2) / (0.85* 1000 ) 0.078
(p) Factor Pu / (Fck * Bc*Bc) 2689902 / ( 20 * 0.85 *1000 * 0.85* 1000 ) 0.186
Using Sp-16 charts for Finding Mux1 and Muy1 Chart No Mu / (Fck * Bc * Bc) n
(r) Uniaxial Moment Mux1 and Muy1 in Kg-m Mux1 = Muy1 = ( 0.11 * 20 * ( 0.85 * 1000 ) ^3 ) 1.351E+09
(s) Check for interaction equation As per IS 456 - 2000 (6.071E+08 / 1.351E+09)^1.173 + (7.758E+08 / 1.351E+09)^1.173 0.913