Sunteți pe pagina 1din 46

S/M No:FM340NL001

Refrigerator

✔ Caution
: In this Manual, some parts can be changed for improving, their
performance without notice in the parts list. So, if you need the
latest parts information,please refer to PPL(Parts Price List) in
Service Information Center (http://svc.dwe.co.kr).

http://svc.dwe.co.kr - Nov, 2007


CONTENTS

1. SPECIFICATIONS
2. EXTERNAL VIEW
3. EXTERNAL PARTS LIST
4. MACHINE ROOM VIEW
5. REFRIGERANT CYCLE
6. TEMPERATURES DIAGRAMS
7. WIRING DIAGRAMS
8. PCB CIRCUIT DIAGRAMS
9. COMPONENTS DISASSEMBLY PICTURES
10. DOOR POSITION CHANGE PROCESS
11. EXPLODE DRAWING
12. PARTS LIST
13. PCB CONTROL FUNCTION

1
1. SPECIFICATIONS
tvklsGuhtl myT[X\~ myT[X\z myT[X^~ myT[X^z
yŒUGŠ–•›™–“G› —Œ ruviGjvu{yvs whulsGjvu{yvs
kvvyGjvsvy ~op{l zps}ly ~op{l zps}ly
yŒ™ŽŒ™ˆ•›G› —Œ yTXZ[ˆ
yŒ™ŽŒ™ˆ•›Gx’›  `\Ž
i“–ž•ŽGˆŽŒ•› jTwlu{hul
j––“•ŽGš š›Œ” mˆ•GŠ––“•ŽGš š›Œ”
kŒ™–š›Gš š›Œ” hœ›–”ˆ›ŠGš›ˆ™›GMGhœ›–”ˆ›ŠGš›–—Gš š›Œ”
j–”—™Œšš–™ q\_soz\GOkhl~vvP
yˆ›Œ‹G–“›ˆŽŒ hjYYW¥Y[W}V\Wo¡
yˆ›Œ‹G•—œ›GOhP XU\
sˆ”—G™ˆ›Œ‹G•—œ›GO~P Y\
n™–šš m™ŒŒ¡Œ™ XYW
}–“œ”Œ yŒ™ŽŒ™ˆ›–™ Y\\
O“›Œ™P
{–›ˆ“ Z^\
lŸ›Œ™•ˆ“ oŒŽ› X_`_
k”Œ•š–• ~‹› \`\
O””P
kŒ—› ]\^
l•Œ™Ž GŠ“ˆšš j

m™ŒŒ¡•ŽGŠˆ—ˆŠ›  [UYrŽVY[
z›ˆ™G™ˆ›•Ž ୖ ୖୖୖ
j“”ˆ›ŒGŠ“ˆšš u
uŒ›GžŒŽ›GO’ŽP ]_

1.2. Types of the approved safety standards

2
2. EXTERNAL VIEW

FR-415W FR-417W
FR-415S FR-417S
X
X\

X]

X[ X^
Z
[ [

X_
Y
\
]

^ _ ^ X` YW

` XX
XY XZ
_

XW

YX

3
3. EXTERAL PART LIST

1. Shelves (3EA) 11. Guide F Case


(In Case F “B”, 1EA)
2. Knob control
(FR-415W/S ONLY) 12. Box ice

3. Multi duct 13. Case icing

4. Medicine chest (BOX ICE) 14. Case egg tray

5. Shelf of vegetable case 15. Cover dairy

6. Knob humidity 16. Dairy pocket

7. Vegetable case “L” 17. Pocket “R”

8. Vegetable case “R” 18. Bottle pocket

9. Case F “B” (2EA) 19. Guide bottle pocket

10. Case F “C” 20. Jumbo pocket

21. Adjustable foot

4
4. MACHINE ROOM VIEW
X Y Z [ \ ] ^

_ ` XW XX XY XZ X[ X\ X]

h
NO PART NAME NO PART NAME

1 PIPE SUC AS 9 BOX RELAY AS

2 ABSORBER SUC PIPE A 10 COMPRESSOR

3 PIPE CONN SUC 11 ABSORBER COMP

4 ABSORBER PIPE B 12 PIPE CONN A

5 PIPE HOT 13 DRYER AS

6 HOSE DRAIN B 14 PIPE WICON AS

7 FIXTURE MOTOR C 15 MOTOR C AS

8 POWER CORD 16 CASE VAPORI AS

h BOX POWER AS (FR-415W/S Models Only)

5
5. REFRIGERANT CYCLE

ov{Gwpwl

z|j{pvuGwpwl

\
l}hwvyh{vy

jhwpsshy€G{|il
Z
ky€ly
[
^
Y
z|j|{pvuGwpwl
X
jvuuU

wpwlGjvuuGh
jvtwylzzvy
wpwlG~pjvuGhz

jvtylzzvy wpwlGjvuuGh wpwlG~pjvuGhz ov{Gwpwl ky€ly

z|jUGwpwlGjvuu z|j{pvuGwpwl l}hwvyh{vy jhwpUG{|il

6
6. TEMPERATURES DIAGRAM

Refrigerator

STEP “5” : -1¶C


STEP “3” : 3¶C
STEP “1” : 5¶C

Vegetables compartment

: 1 ~5¶C

Freezer

: -20¶C ~ -18¶C

7
7. WIRING DIAGRAMS

7.1. FR-417W, FR-417S

8
7. WIRING DIAGRAMS

7.2. FR-415W, FR-415S

9
8. PCB CIRCUIT DIAGRAMS

10
9. COMPONENTS DISASSEMBLY PICTURES

1. FRONT PCB (FR-417W, FR-417S only)

- Input a cutter sleeve between


Window FCP and Panel F control.

Important : Input carefully cutter


in the area that picture shows
(downside).

- Lift Window FCP up

* Remark : Input cutter deeply and


carefully in order to lift up easily
and avoid paint damages and
scratches.

- Unscrew Panel F Control.

11
- Unscrew the 3 fixing screws of
F-PCB as.

2. SWITCH DOOR
- Force switch door to the left side
and input a thin driver in the right
part as picture shows.
After this operation, lift switch up.

* Remark : Input driver carefully in


order to lift up easily and avoid
scratches.

- Move switch to left side.

- Take out switch and disconnect


housing.

12
3. M-PCB(FR-417W, FR-417S only)
- Unscrew the 3 fixing screws of
cover PCB box.

- Disconnect all housings


connectors from M-PCB, and
force plastic locker of PCB box in
order to take out the PCB.

4. RELAY BOX COVER


- Press relay box cover stopper
sleeve with a minus driver like
picture shows.

13
5. MULTI DUCT

-Take off the 2 screw caps and


unscrew all fixing screws.

- kšŠ–••ŒŠ›Gˆ““G–œš•ŽšGŠ–••ŒŠ›–™š

- To disassemble R-sensor lift it


up from the wires carefully.

14
6. LOUVERS
- Unscrew the left fixing screw for
disassembly “LOUVER F AS” and
“LINER”. screw

-Take out “LOUVER F AS” pulling the


right side with a tool like hook.
୔ Because the right side lock is too
tight, disassemble carefully.
୔ To assemble “LOVER F AS” and
“LINER”, push the right side lock (look
the red arrow) until making the click of
the lock.

Position of
“Right Side Lock”

- Disconnect fan motor housing.

- Unscrew the 3 fixing screws in


order to disassemble Louver A.

15
- When louvers are disassembled
is very important check Knob F
louver position.

Default position is M

7. CHANGE DOOR OPEN SIDE


- Unscrew cover T hinge.

- Before changing door open side,


disconnect door housing
connector.

Follow next sheets instructions to


change door open side

16
10. DOOR POSITION CHANGE PROCESS

STEP 1 : Remove door Follow to remove


X
1. Remove “COVER HINGE T” and
“HINGE T”

2. Remove “R door”.

Y 3. Remove “HINGE M”

4. Remove “F door”

5. Remove “COVER BRACKET”

Z 6. Remove “HINGE U”
]
\

STEP 2 : Change the position 7. Reverse the position of “Cover


of door components Bushing R door”

<FR-417W/S ONLY>
7-1. Unscrew and remove two
^ “Harness Covers”
7-2. Take out “Left door harness”
and take in “Right door harness”
7-3. Attach and screw two “Harness
covers”
`

8. Reverse the position of “CAP DR


BUSHING F door”
_

9. Reverse the position of “Door


` Stoppers”

17
STEP 3 : Change door open side 10. Attach the “HINGE U” on the left.
11. Attach the “F door”.
14-1
12. Reverse the position of “HINGE
15 M” and “COVER HINGE M”
13. Attach the “R door”
14
* Door F and R ‹–G›–GŽŒ›G•›–
13 –™¡–•›ˆ“› G–•Gšœ™ˆŠŒG–G“ˆ•‹U
QG{ŒGŽˆ—G‰Œ›žŒŒ•G‹––™GmGˆ•‹Gy
’ŒŒ—Gˆ‰–œ›GXWU\GŠ”UG

14. Attach the “HINGE T” on the left


of cabinet after assembling to “R
12 door”
<FR-417W,FR-417S ONLY>
14-1. Attach the “Door harness”
14-2. Reverse the position of
11 “COVER CAB HARNESS”
10 10
15. Reverse the position of “COVER
HINGE T”
16
16. Attach the “COVER BRACKET”

{ŒG—–š›–•G–G“opunlGt” {ŒG—–š›–•G–G“opunlG|”

sŒ›G› —Œ yŽ›G› —Œ
sŒ›G› —Œ yŽ›G› —Œ

18
11. EXPLODED DRAWING

11.1. FR-417W, FR-417S


ྙ CABINET

19
11. EXPLODED DRAWING

11.1. FR-417W, FR-417S:


ྚ MACH ROOM

ྛ F ROOM

20
11. EXPLODED DRAWING

11.1. FR-417W, FR-417S:


ྜ R ROOM

ྜྷ F/R DOOR

21
11. EXPLODED DRAWING

11.2. FR-415W, FR-415S


ྙ CABINET

22
11. EXPLODED DRAWING

11.2. FR-415W, FR-415S:


ྚ MACH ROOM

ྛ F ROOM

23
11. EXPLODED DRAWING

11.2. FR-415W, FR-415S:


ྜ R ROOM

ྜྷ F/R DOOR

24
12. PARTS LIST

12.1. FR-417W, FR-417S


ྙ CABINET
NO PART CODE PART NAME Q’ty SEPCIFICATION

1 3000077400 ASSY CAB URT 1 RFP-340(WHITE)


3000077420 RFP-340(SILVER)
2 3012929000 HINGE *T AS 1 P0, T2.6
3 3016001250 SPECIAL BOLT *M 3 6X15 SWCH22A(WH)

4 3001411900 COVER *T HI 1 PP(WHITE)

3001411910 PP(SILVER)
5 3016003400 SPECIAL BOLT 1 T1 M5X14

6 3001412200 COVER CAB HRNS 1 PP(WHITE)


3001412210 PP(SILVER)
7 3016003400 SPECIAL BOLT 1 T1 M5X14
8 3010563800 BOX M/PCB AS 1 RFP-340
9 7112401211 SCREW TAPPING 4 T1 TRS 4X12 MFZN
10 30143G1060 PCB MAIN AS 1 V-LAZER (RFP-341SV)

11 3001416600 COVER M/PCB BOX AS 1 COVER(WHITE)+TAPE


3001416610 COVER(SILVER)+TAPE
12 7112401211 SCREW TAPPING 3 T1 TRS 4X12 MFZN
13 3013000800 HOLDER POWER CORD 1 FRB-5250NB
14 7112401211 SCREW TAPPING 1 T1 TRS 4X12 MFZN
15 3018120200 SWITCH DR AS 1 83430-109-19(NO.411260025)
16 3010937700 CAP DV HI HOLE *M 1 ABS
17 3012928900 HINGE *M AS 1 RFP-340
18 3016001250 SPECIAL BOLT *M 2 ]X\Gz~joYYhO~oP
19 3012929100 opunlGQ|Ghz 1 RFP-340
20 3016001240 SPECIAL BOLT *T 4 ]YYGz~joYYhO€sP
21 3012105100 FOOT ADJ AS 2 PP

22 3001415600 COVER CAB BRKT AS 1 COVER(WHITE) + VINYL


3001415610 COVER(SILVER) + VINYL

25
12. PARTS LIST

12.1. FR-417W, FR-417S


ྚ MACH ROOM
NO PART CODE PART NAME Q’ty SEPCIFICATION
23 3010349300 BASE COMP AS 1 RFP-340
24 3016003300 SPECIAL BOLT 4 T2 M6.5X20
25 3011349300 CORD POWER AS 1 16A , 250V
26 7S422X4081 SPECIAL SCREW 1 TT3 TRS 4X8 SE MFZN
27 7112401211 SCREW TAPPING 1 T1 TRS 4X12 MFZN
28 3954158J50 COMPRESSOR 1 JX58LHS5 220V-50HZ
29 3016002500 SPECIAL WASHER 4 SK-5 T0.8
30 3010101600 ABSORBER COMP 4 NBR
31 3018131800 SWITCH P RELAY AS 1 RFP(M)-340
32 3811400503 COVER RELAY 1 PRF(M)-340
33 3011122800 CASE VAPORI AS 1 PP+TAPE ALUMINUM
34 3013202700 HOSE DRN B 1 PP
35 3015918100 MOTOR C AS 1 2400RPM 230V/50Hz
36 3012004400 FIXTURE C MOTOR 1 SUS
37 3010102100 ABSORBER C MOTOR 1 NR FRB-5350NT
38 3011802200 FAN 1 ABS OD3.17XD110
39 3011200510 CLAMP FAN 1 SUS 304 (SPRING)
40 3014469600 PIPE WICON AS 1
41 3016808100 DRYER AS 1 C1220T-M OD19.0XL135
42 3001414000 COVER MACH RM AS 1 ABS
43 7112401211 SCREW TAPPING 7 T1 TRS 4X12 MFZN

26
12. PARTS LIST

12.1. FR-417W, FR-417S


ྛ F ROOM
NO PART CODE PART NAME Q’ty SEPCIFICATION
44 3017065200 EVA AS 1 RFP-340
44-1 3017065300 EVA SAS 1
44-2 3017202800 FUSE TEMP AS 1
44-3 4017Z90590 FIXTURE FUSE TEMP 1 PP
44-4 3012764100 HARNESS D SENS 1 DA-140
45 3012822000 HEATER D AS 1
46 3018923300 LOUVER F AS 1 RFP-340
46-1 3018923700 LOUVER F A AS 1 LOUVER F A+SEAL
46-2 3018923800 LOUVER F B AS 1
46-2-1 3018923100 LOUVER F B 1 PP
46-2-2 3010107100 ABSORBER F MOTR 1 NBR
46-2-3 3015918200 MOTOR F AS 1 2500RPM 230V/50Hz
46-2-4 3010664700 BRACKET FAN MOTR 1 PP, T2.0
46-2-5 7112401011 SCREW TAPPING 1 T1 TRS 4X10 MFZN
46-3 3011836000 FAN AS 1 FAN+CLAMP
46-3-1 3011835900 FAN 1 Ժ100, SHAFT Ժ3.17
46-3-2 3011200510 CLAMP FAN 1 SUS 304 (SPRING)
46-4 3013413500 KNOB F CONTL 1 PP
46-5 7112401011 SCREW TAPPING 3 T1 TRS 4X10 MFZN
47 7112401211 SCREW TAPPING 1 T1 TRS 4X12 MFZN
48 3011122700 CASE F C AS 1 CASE+DECO
49 3011122600 CASE F B AS 1 CASE+DECO
50 3011192900 CASE F B AS 1 CASE+DECO+GUIDE
51 3010564400 BOX ICE 1 GPPS
52 4010G56012 CASE ICING 1 ww

27
12. PARTS LIST

12.1. FR-417W, FR-417S


ྜ R ROOM
NO PART CODE PART NAME Q’ty SEPCIFICATION
53 3001413500 COVER MULTI DUCT AS 1 RFP-340
53-1 3001413000 COVER MULTI DCUT 1 HIPS, T2.0(RFP-340)
53-2 3017903900 SOCKET LAMP AS 1 AC250V
53-3 7121300811 SCREW TAPPING 1 T2S PAN 3X10 MFZN
53-4 3012764600 HRANESS R SENS 1 RFP-340
53-5 3013369300 INSU MULTI DUCT 1 F-PS
54 7112401211 SCREW TAPPING 2 T1 TRS 4X12 MFZN
55 3010924600 CAP F LOUVER 2 HIPS T2.3
56 3013603000 LAMP 1 240V/25W (BLUE)
57 3015513100 WINDOW R 1 MIPS
58 3011122400 CASE VEGETB *L 1 GPPS
59 3011122500 CASE VEGETB *R 1 GPPS
60 3001413300 COVER V/CASE AS 1 COVER+KNOB
61 3017847100 SHELF R INSERT AS 3
62 3010519501 BOX ICE AS (MEDICINE CHEST) 1 FRB-5580NB

28
12. PARTS LIST

12.1. FR-417W, FR-417S


ྜྷ F/R DOOR
NO PART CODE PART NAME Q’ty SEPCIFICATION
3000077800 RFP-340(WHITE)
63 ASSY R DR 1
3000077820 RFP-340(SILVER)
3000077900 RFP-340(WHITE)
63-1 ASSY R DR URT 1
3000077920 RFP-340(SILVER)
63-2 3012321200 GASKET R DR AS 1
3014240100 RFP-340(WHITE)
64 PANEL F PCB AS 1
3014240110 RFP-340(SILVER)
64-1 30143G1160 PCB FRONT AS 1 V-LAZER FRONT AS(RFP-340)
3014240000 RFP-340(WHITE)
64-2 PANEL F CONTL 1
3014240010 RFP-340(SILVER)
64-3 3016306400 BUTTON FCP 2 ABS
64-4 7173300611 SCREW TAPPTITE 2 TT2 BIN 3X6 MFZN
65 7122401211 SCREW TAPPING 3 T2S TRS 4X12 MFZN
66 3015513000 WINDOW FCP 1 ABS+FILM
3000077500 RFP-340(WHITE)
67 ASSY F DR 1
3000077510 RFP-340(SILVER)
3000077600 RFP-340(WHITE)
67-1 ASSY F DR URT 1
3000077610 RFP-340(SILVER)
67-2 3012321100 GASKET F DR AS 1
68 3019031400 POCKET DAIRY AS 1 GPPS+HIPS
68-1 3001412300 COVER DAIRY POKT 1 GPPS
68-2 3019031000 POCKET DAIRY 1 HIPS
69 3011190800 CASE EGG TRAY 1 GPPS
70 3019031200 POCKET R 1 HIPS
71 3019030900 POCKET BOTL 1 HIPS
72 3019031100 POCKET JUMBO 1 HIPS
73 3012532100 GUIDE BOTL POKT 1 HIPS

29
12. PARTS LIST

12.2. FR-415W, FR-415S


ྙ CABINET
NO PART CODE PART NAME Q’ty SEPCIFICATION
3000077410 RFM-340(WHITE)
1 ASSY CAB URT 1
3000077430 RFM-340(SILVER)

2 3012929000 HINGE *T AS 1 P0, T2.6


3 3016001250 SPECIAL BOLT *M 3 6X15 SWCH22A(WH)
3001411900 PP(WHITE)
4 COVER *T HI 1
3001411910 PP(SILVER)

5 3016003400 SPECIAL BOLT 1 T1 M5X14


6 3013000800 HOLDER POWER CORD 1 FRB-5250NB
7 7112401211 SCREW TAPPING 1 T1 TRS 4X12 MFZN
8 3018120200 SWITCH DR AS 1 83430-109-19(NO.411260025)
9 3010937700 CAP DV HI HOLE *M 1 ABS
10 3012928900 HINGE *M AS 1 RFP-340
11 3016001250 SPECIAL BOLT *M 2 6X15 SWCH22A(WH)
12 3012929100 HINGE *U AS 1 RFP-340
13 3016001240 SPECIAL BOLT *T 4 6X22 SWCH22A(YL)
14 3012105100 FOOT ADJ AS 2 PP
3001415600 COVER(WHITE) + VINYL
15 COVER CAB BRKT AS 1
3001415610 COVER(SILVER) + VINYL

30
12. PARTS LIST

12.2. FR-415W, FR-415S


ྚ MACH ROOM
NO PART CODE PART NAME Q’ty SEPCIFICATION
16 3010349300 BASE COMP AS 1 RFP-340
17 3016003300 SPECIAL BOLT 4 T2 M6.5X20
18 3011348410 CORD POWER AS 1 FRM-510, 250V/16A
19 7S422X4081 SPECIAL SCREW 1 TT3 TRS 4X8 SE MFZN
20 7112401211 SCREW TAPPING 1 T1 TRS 4X12 MFZN
21 3010563900 BOX POWER AS 1 RFM-340
22 7112401211 SCREW TAPPING 2 T1 TRS 4X12 MFZN
23 3954158J50 COMPRESSOR 1 JX58LHS5 220V-50HZ
24 3016002500 SPECIAL WASHER 4 SK-5 T0.8
25 3010101600 ABSORBER COMP 4 NBR
26 3018131800 SWITCH P RELAY AS 1 RFP(M)-340
27 3811400503 COVER RELAY 1 PRF(M)-340
28 3011122800 CASE VAPORI AS 1 PP+TAPE ALUMINUM
29 3013202700 HOSE DRN B 1 PP
30 3015918100 MOTOR C AS 1 2400RPM 230V/50Hz
31 3012004400 FIXTURE C MOTOR 1 SUS
32 3010102100 ABSORBER C MOTOR 1 NR FRB-5350NT
33 3011802200 FAN 1 ABS OD3.17XD110
34 3011200510 CLAMP FAN 1 SUS 304 (SPRING)
35 3014469600 PIPE WICON AS 1
36 3016808100 DRYER AS 1 C1220T-M OD19.0XL135
37 3001414000 COVER MACH RM AS 1 ABS
38 7112401211 SCREW TAPPING 7 T1 TRS 4X12 MFZN

31
12. PARTS LIST

12.2. FR-415W, FR-415S


ྛ F ROOM
NO PART CODE PART NAME Q’ty SEPCIFICATION
39 3017065210 EVA AS 1 RFP-340
39-1 3017065300 EVA SAS 1
39-2 3017202800 FUSE TEMP AS 1
39-3 4017Z90590 FIXTURE FUSE TEMP 1 PP
39-4 3018132300 SWITCH BIMTL AS 1 250V 7.5A (ON:9 / OFF:-4୅)
39-5 4856813100 CABLE TIE 1 DA-140
40 3012822000 HEATER D AS 1
41 3018923300 LOUVER F AS 1 RFP-340
41-1 3018923700 LOUVER F A AS 1 LOUVER F A+SEAL
41-2 3018923800 LOUVER F B AS 1
41-2-1 3018923100 LOUVER F B 1 PP
41-2-2 3010107100 ABSORBER F MOTR 1 NBR
41-2-3 3015918200 MOTOR F AS 1 2500RPM 230V/50Hz
41-2-4 3010664700 BRACKET FAN MOTR 1 PP, T2.0
41-2-5 7112401011 SCREW TAPPING 1 T1 TRS 4X10 MFZN
41-3 3011836000 FAN AS 1 FAN+CLAMP
41-3-1 3011835900 FAN 1 Ժ100, SHAFT Ժ3.17
41-3-2 3011200510 CLAMP FAN 1 SUS 304 (SPRING)
41-4 3013413500 KNOB F CONTL 1 PP
41-5 7112401011 SCREW TAPPING 3 T1 TRS 4X10 MFZN
42 7112401211 SCREW TAPPING 1 T1 TRS 4X12 MFZN
43 3011122700 CASE F C AS 1 CASE+DECO
44 3011122600 CASE F B AS 1 CASE+DECO
45 3011192900 CASE F B AS 1 CASE+DECO+GUIDE
46 3010564400 BOX ICE 1 GPPS
47 4010G56012 CASE ICING 1 ww

32
12. PARTS LIST

12.2. FR-415W, FR-415S


ྜ R ROOM
NO PART CODE PART NAME Q’ty SEPCIFICATION
48 3001415700 COVER MULTI DUCT AS 1 RFM-340
48-1 3001413010 COVER MULTI DCUT 1 HIPS, T2.0(RFM-340)
48-2 3017903900 SOCKET LAMP AS 1 AC250V
48-3 7121300811 SCREW TAPPING 1 T2S PAN 3X10 MFZN
48-4 3018305700 THERMOSTAT 1 RFM-340
48-5 3012764700 HARNESS THERMO AS 1 RFM-340
48-6 3013413600 KNOB R CONTL 1 HIPS
48-7 3013369300 INSU MULTI DUCT 1 F-PS
49 7112401211 SCREW TAPPING 2 T1 TRS 4X12 MFZN
50 3010924600 CAP F LOUVER 2 HIPS T2.3
51 3013603000 LAMP 1 240V/25W (BLUE)
52 3015513100 WINDOW R 1 MIPS
53 3011122400 CASE VEGETB *L 1 GPPS
54 3011122500 CASE VEGETB *R 1 GPPS
55 3001413300 COVER V/CASE AS 1 COVER+KNOB
56 3017847100 SHELF R INSERT AS 3
57 3010519501 BOX ICE AS (MEDICINE CHEST) 1 FRB-5580NB

33
12. PARTS LIST

12.2. FR-415W, FR-415S


ྜྷ F/R DOOR
NO PART CODE PART NAME Q’ty SEPCIFICATION
3000077810 RFM-340(WHITE)
58 ASSY R DR 1
3000077830 RFM-340(SILVER)
3000077910 RFM-340(WHITE)
58-1 ASSY R DR URT 1
3000077930 RFM-340(SILVER)
58-2 3012321200 GASKET R DR AS 1
3000077500 RFM-340(WHITE)
59 ASSY F DR 1
3000077510 RFM-340(SILVER)
3000077600 RFM-340(WHITE)
59-1 ASSY F DR URT 1
3000077610 RFM-340(SILVER)
59-2 3012321100 GASKET F DR AS 1
60 3019031400 POCKET DAIRY AS 1 GPPS+HIPS
60-1 3001412300 COVER DAIRY POKT 1 GPPS
60-2 3019031000 POCKET DAIRY 1 HIPS
61 3011190800 CASE EGG TRAY 1 GPPS
62 3019031200 POCKET R 1 HIPS
63 3019030900 POCKET BOTL 1 HIPS
64 3019031100 POCKET JUMBO 1 HIPS
65 3012532100 GUIDE BOTL POKT 1 HIPS

34
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

1. DISPLAY

INPUT CONTROL OBJECT

̻ PCB Control Panel Buttons ̻ PCB Control Panel LED

Temperature adjustment
button for refrigerator
“Super Cool” button
compartment.

REFERENCE
PAGE

LED DISPLAY FUNCTION OPERATION


36 LED “3” on TEMP STEP “3” Push “TEMP” button 1 time.
LED “4” on TEMP STEP “4” Push “TEMP” button 2 times.
LED “5” on TEMP STEP “5” Push “TEMP” button 3 times.
LED “1” on TEMP STEP “1” Push “TEMP” button 4 times.
LED “2” on TEMP STEP “2” Push “TEMP” button 5 times.
LED “S-COOL” on TEMP S-COOL Push “S-COOL” button 1 time.
44 LED “3” on ERROR “R SENSOR” (R1) Push “S-COOL” button for continuously
and “TEMP” button 5 times.
LED “2” on ERROR “RT SENSOR” (RT) In Error Mode the "4" & "5" LED flicker.
LED “1” on ERROR “D SENSOR” (D1)

LED “2” & "3" on ERROR “DOOR S/W” (DR)


*The Priorities of Error :
LED “1” & "3" on ERROR “CYCLE” (C1) R SENSOR> RT SENSOR> DR S/W>
LED “1” & "2" on ERROR “DEFROST” (F3) CYCLE> DEFROST

37 “3” & “S-COOL” on, Forced Defrost Test Push “TEMP” button for continuously and
“4” & ”5” flicker “S-COOL” button 5 times.
Display)
And then, push “S-COOL” button for
continuously and “TEMP” button 5 times.
40 “1” & “S-COOL” on Pull Down Test Push “TEMP” button 30 times.
“4” & ”5” flicker
Display)
And then, push “S-COOL” button for
continuously and “TEMP” button 5 times.

35
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

2. Temperature Control of Refrigerator Compartment

INPUT CONTROL OBJECT


̻ PCB Control Panel “TEMP” Buttons ̻ PCB Control Panel LED
̻ R-sensor ̻ COMPRESSOR, FAN

A. “TEMP” Button
ཿ Temperature control of Refrigerator compartment
ྀ 5 step mode of successive temperature mode
ཱྀ Initial mode by power input: step “3”
ྂ Temperature will be set if the button doesn’t get pressed again within 5 sec.
୔ Whenever pressing “TEMP” button, setting is repeated in the order of
“3” ˧ “4” ˧ “5” ˧ “1” ˧ “2” (LED LAMP ON)

B. Temperature of Refrigerator Control


ཿ COMP and FAN will be controlled by the on/off condition of each mode.
ྀ Temperature Difference of Refrigerator each step :

Temperature Step “1” “2” “3” “4” “5”

Temp. Diff. of Each Step 1.5¶C 1.5¶C 2.0¶C 2.0¶C

ཱྀ Temperature of Refrigerator
at step “3” OFF point: 1.6¶C
ྂ Refrigerator ON/OFF Temp.
Difference: 1.7¶C

6.3¶C
C. “S-COOL” MODE
ཿ Press S-COOL SWITCH
and make S-COOL led lamp on. 4.8¶C
4.6¶C
ཱྀ COMP & FAN are on until R-sensor
reaches to “Over Refrigeration
3.3¶C
OFF Point”, -7¶C 3.1¶C
ྂ After the reach of -7¶C , STEP “5” mode continues.
ྀ When “S-COOL” MODE (Quick Refrigeration Mode)
1.6¶C
lasts for about 40 minutes, it returns to general 1.3¶C
operation mode.

OFF
D. Temperature of Freezer Control -0.4¶C
-0.7¶C
-It will be only controlled by using
“KNOB F LOUVER” in Freezer.

-2.4¶C ON

STEP “1” “2” “3” “4” “5”

36
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

3. Defrost Mode

INPUT CONTROL OBJECT


̻ Total COMP Work Time ̻ COMP Working Rate
̻ Defrost Mode
̻ Total Door Open Time ̻ RT

̻ Conditions of Defrost Mode

A. When total operation time of compressor becomes: 6, 8, 10, 12 hours.


ཿ any error mode-R1, D1, F3, C1, RT/S, Door SW error- happens.
ྀ or, running rate of COMP (per 2hrs of total operation time) is more than 80%.
ཱྀ or, total door open time is over 3 minutes.
ྂ or, ambient temperature (RT) is more than 40¶C.
B. Even if the above condition “A” is not satisfied,
ཿ Defrost mode starts immediately when total operation time of COMP is 14hrs.
ྀ or, defrost mode starts immediately as long as total time (COMP on time + COMP off time) is 60 hrs.

̻ Defrost Mode

A. General Defrost Mode


ཿ How to start: By conditions of defrost
ྀ Process :
General operation˧
“PRE-COOL” ˧ Defrost Heater on˧ Pause(10 min)˧General operation
୔ PRE-COOL: When the defrost heater works, the temp. of freezer increases.
So the COMP works for 25 min before defrost mode.
ཱྀ Limited Time of Defrost Heater
̻ 40 minutes: Heater turns off when “D SENSOR” is OPEN or SHORT.

̻ 50 minutes: Heater turns off after 50 minutes.

ྂ Heater Off: When the temperature at “D SENSOR” is over 10¶C

PRE-COOL Defrost Mode Pause


Compressor ON OFF OFF
Fan ON OFF OFF
Defrost Heater OFF ON OFF

B. Forced Defrost Mode


ཿ How to start: by press “TEMP” button for continuously and “S-COOL” button 5 times.
ྀ Process: same as General Defrost Mode except “PRE-COOL”
୔ Heater is supposed to be on Initial 30 seconds even though the temp. at “D SENSOR” is over 10¶C.
(for TEST)
ཱྀ How to confirm: by press “S-COOL” button for continuously and “TEMP” button 5 timesUG
And then, the mode displays.
ྂ Display : led lamps “3”MG“zTjvvs” on, “4” & ”5” on/off continually

37
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

3. Defrost Mode

INPUT CONTROL OBJECT


̻ Total COMP Work Time ̻ COMP Working Rate
̻ Defrost Mode
̻ Total Door Open Time ̻ RT

̻ Initial Defrost

A. In providing initial power or returning power failure,


if the temperature at the D-sensor is under 3.5¶C, Defrost Mode starts. (It proceeds from “PRE-COOL”.)
[ “PRE-COOL” ˧ Heater on ˧ Pause(10 min) ˧ General operation ]
B. Initial defrost mode starts after “Prevention of Compressor Restart”. (Refer to Function No. 5)

̻ Flow Chart of Defrost Start


Start

NO
COMP time ˻ 2hrs

YES
YES
Total time ˻ 60hrs

NO
YES
COMP time ˻ 14hrs

N0
NO
COMP time ˻ 6hrs

YES
YES
COMP Rate ˻ 80%

N0
YES
Any error?

NO
YES
RT Temp ˻ 40¶C

N0
YES
Total door open time
˻ 3 min?

NO

Defrosting start END

38
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

4. Function of Low Ambient Temperature (RT)

INPUT CONTROL OBJECT


̻ R-HTR
̻ RT
̻ COMP

A. Condition of LOW RT
ཿ LOW RT Period : RT sensor ˺ 19¶C
ྀ When the temperature of RT sensor is over 20¶C, the system comes to be “General Operation Mode”.
ཱྀ When the temp. of RT sensor is between 19¶C to 20¶C, the system keeps the previous mode.
B. Control
ཿ When Comp. is on, R-HTR is off.
ྀ When it passes 6 min after COMP is off, R- HTR is on.
ཱྀ COMP can’t be on within 30 min after COMP is off.
୔ COMP doesn’t work at the steps “Heater On” and “Pause” of “Defrost Mode”.
If COMP comes to be off for “Low Room Temp” in the steps, it seems to take over 30 minutes.
ྂ Change of “Prevention Time of COMP Restart” :
If satisfy the following conditions simultaneously, the time changes 6 minutes.
̻ Accumulated running time of COMP passes 20 seconds after COMP is off.

̻ R-Sensor is more than ‘ON’ Point TEMP.

ྃ When it is not the mode of LOW ROOM TEMP


or RT-Sensor is on ERROR (open or short), R-Sensor HTR is off.
྄ Function of R-Heater Inspection:
After initial power is on, R-HTR is on/off 5times for 10 seconds.

5. Prevention of Compressor Restart


INPUT CONTROL OBJECT
̻ COMP
COMP. doesn’t work after COMP turns off even though R-sensor is on condition. (This is to protect comp.)
A. General operation (Temp. at the RT sensor ˻ 20¶C): The COMP can’t be on within 6 min.
B. Operation of LOW RT (Temp. at the RT sensor ˺ 19¶C):
The COMP can’t be on within 30 min.
(But the COMP can be on after 6min when the doors open more than 20 seconds.)

6. Buzzer Sound

INPUT CONTROL OBJECT


̻ Control Buttons ̻ Door Switch
̻ Buzzer
̻ Initial Power Input

A. Whenever “PCB Control Panel” button’s pushed, the buzzer rings.


B. After 2 seconds power’s on, the buzzer rings 3 times.
C. Time of Buzzer: Forced Defrost Mode (3 times), Pull Down Test (1 time)
D. When door opens, the buzzer rings every 1 minute for 5 minutes.

39
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

7. Pull Down Test

INPUT CONTROL OBJECT

̻ “TEMP” Button ̻ COMP & FAN

A. How to start: by pressing “TEMP” button 30 times continuously.


B. How to confirm: by pressing “S-COOL” button for continuously and “TEMP” button 5 timesUG
And then, the mode displays.
C. How to control:
ཿ COMP & FAN will be on independent of the operating condition. (There is no defrost mode on this test.)
ྀ It is available to restart the test and it’ll be take 30 hours.
D. CANCEL : after the limit test time 30 hours passes.
E. DISPLAY : LED lamp “1” and “S-COOL” are on and “4” & ”5”are flickeringly.

8. Time Reduction

INPUT CONTROL OBJECT

̻ ”FAST KEY” ̻ Buzzer

A. HOW TO REDUCE
ཿ 1 min : Click FAST KEY one time on MAIN PCB.
ྀ 30 min : If you press FAST KEY continuously, you can reduce 30 minutes on each 2.5 seconds with buzzer.
B. Practice Use : Can be applied to reduce needless time on test.
EX) function of stop for 6 min

9. Demonstration Function

INPUT CONTROL OBJECT

̻ “TEMP” +”S-COOL” Buttons ̻ Display Panel

A. START : by pressing “TEMP” and “S-COOL” buttons for 5 seconds.


B. CONTROL :
ཿ All electronic compartments are off except “Display Panel”.
ྀ When “DEMO” mode works, led lamps will be on as next steps.
[ “1” ˧ “2” ˧ “3” ˧ “4” ˧ “5” ˧ “1”]
D. CANCEL :
Push again “TEMP” and “S-COOL” buttons for 5 seconds at “DEMO”, or turn off power and restart.

40
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

10. Control of R-sensor OFF Point

INPUT CONTROL OBJECT

̻ ”J1, J2” On Main PCB ̻ Control Resistance of R sensor OFF Point

A. LOW COOLING OPTION


- When the refrigeration of refrigerator is poor or weak though Fan and COMP are working continuously,
the following actions are recommended for service.
̻ Resistance (R47) : Default resistance (31.4Kohms)

̻ Resistance (R45) : Cut the “J1” (2K˟ up)

̻ Resistance (R42) : Cut the “J2” off additionally (total 4K˟ up)

R47 = R-SENSOR OFF point


R47 + R45 = R-SENSOR OFF point - 1.5¶C
R47 + R45 + R42 = R-SENSOR OFF point - 3¶C

yTzluzvy

y[^OZXU[rP

y[\OYrP
qX

y[YOYrP
qY

41
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

10. Control of R-sensor OFF Point

INPUT CONTROL OBJECT

̻ Input voltage of MICOM


̻ ”J3” & “R30” On Main PCB
̻ R-sensor ON/OFF Point

B. Prevention OPTION of EXCESSIVE OR LOW COOLING.

\} tpjvt

yZX
yZY GY]wpu
}ˆ vw{pvuGZ
Ow]ZP
yZW qZ jjZ

* The input voltage of MICOM and R-Sensor ON/OFF point by changing J3 & R30.

TEMP. STEP “3” APPLICATION MICOM Compared to


NO
ON OFF (MAIN PCB) INPUT VOL. “STANDARD”

1 1.9πC 0.2πC - 0V STANDARD


2 0.1πC -1.6πC J3(CUT), R30 (‫ױ‬680Խ) 0.3V -1.8πC
3 0.5πC -1.2πC J3(CUT), R30 (‫ױ‬2໰) 0.8V -1.4πC
4 0.8πC -0.9πC J3(CUT), R30 (‫ױ‬2.8໰) 1.1V -1.1πC
5 1.2πC -0.5πC J3(CUT), R30 (‫ױ‬3.92໰) 1.4V -0.7πC
6 1.5πC -0.2πC J3(CUT), R30 (‫ױ‬4.87໰) 1.6V -0.4πC
7 2.3πC 0.6πC J3(CUT), R30 (‫ױ‬6.65໰) 2.0V +0.4πC
8 2.6πC 0.9πC J3(CUT), R30 (‫ױ‬10໰) 2.5V +0.7πC
9 3.0πC 1.3πC J3(CUT), R30 (‫ױ‬19.6໰) 3.3V +1.1πC
10 3.3πC 1.6πC J3(CUT), R30 (‫ױ‬40.2໰) 4V +1.4πC
11 3.7πC 2.0πC J3(CUT), R30(NO USE) 5V +1.8πC

42
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

10. Control of R-sensor OFF Point

INPUT CONTROL OBJECT

̻ Input voltage of MICOM


̻ ”J4” & “R23” On Main PCB
̻ R-sensor ON/OFF Point

C. Changing Difference between R-sensor “On” point and “Off” point.

\} tpjvt

yY\
yY_ GY^wpu
}ˆ vw{pvuGY
Ow][P
yYZ q[ jj]

* The input voltage of MICOM and R-Sensor ON/OFF DIFF. by changing J4 & R23.

TEMP. STEP “3” APPLICATION MICOM DIFFERENCE OF


NO
ON OFF (MAIN PCB) INPUT VOL. ON/OFF POINT

1 1.9πC 0.2πC - 0V 1.7πC


2 0.6πC 0.2πC J4(CUT), R23 (‫ױ‬680Խ) 0.3V 0.4πC
3 0.9πC 0.2πC J4(CUT), R23 (‫ױ‬2໰) 0.8V 0..7πC
4 1.3πC 0.2πC J4(CUT), R23 (‫ױ‬2.8໰) 1.1V 1.1πC
5 1.6πC 0.2πC J4(CUT), R23 (‫ױ‬3.92໰) 1.4V 1.4πC
6 2.3πC 0.2πC J4(CUT), R23 (‫ױ‬4.87໰) 1.6V 2.1πC
7 2.7πC 0.2πC J4(CUT), R23 (‫ױ‬6.65໰) 2.0V 2.5πC
8 3.0πC 0.2πC J4(CUT), R23 (‫ױ‬10໰) 2.5V 2.8πC
9 3.4πC 0.2πC J4(CUT), R23 (‫ױ‬19.6໰) 3.3V 3.2πC
10 3.7πC 0.2πC J4(CUT), R23 (‫ױ‬40.2໰) 4V 3.5πC
11 4.1πC 0.2πC J4(CUT), R23(NO USE) 5V 3.9πC

43
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

11. Error Display

INPUT CONTROL OBJECT

̻ PCB Control Panel Buttons ̻ Door ̻ LED Lamp

- ERROR DISPLAY
- To confirm error happens or not, push S-COOL” button for continuously and “TEMP” button 5 times.
- To stop the Error Display Set, push “TEMP” button 1 times, or wait 4 minutes.
- After operations back to normal, the displays come to be reset.
A. R1 ERROR
(It happens when R-Sensor is OPEN or SHORT)
ཿ DISPLAY : STEP “3” LED is on & off continually.
ྀ CONTROL :
- Controlled by the following condition of RT
- When “RT ERROR” happens at the same time, “COMP. ON/OFF Operating Time” is 16min/24min.
(Unit : min)
RT sensor TEMP ~13¶C ~19¶C ~29¶C 29¶C~
COMP. Operating TIME
6/34 10/30 16/24 20/20
(ON/OFF)

ཱྀ CANCEL : when R-Sensor is working normally.


B. RT ERROR
(It happens when RT-Sensor is OPEN or SHORT)
ཿ DISPLAY : STEP “2” LED is on & off continually.
ྀ CONTROL : Delete the conditions of “RT-sensor Control” and operate normally.
ཱྀ CANCEL : when RT-Sensor is working normally.
C. D1 ERROR
CODE LED ON ERROR
(It happens when D-Sensor is OPEN or SHORT)
ཿ DISPLAY : STEP “1” LED is on & off continually. R1 “3” R sensor
ྀ CONTROL : Return to next limit defrost time (40 min)
ཱྀ CANCEL : when D-Sensor is working normally. RT “2” RT sensor
D. DR ERROR
(It happens when the system senses door opens more than 1 hour.) D1 “1” D sensor
ཿ DISPLAY : STEP “2”, “3” LED Lamps are on & off continually.
DR “2”, “3” DR Switch
ྀ CONTROL : Deletion of function related door switch sensing
ཱྀ If door switch (open & close) is sensed, the error is terminated C1 “1”, “3” Cycle
automatically
E. C1 ERROR F3 “1”, “2” Defrost
(When D-Sensor is more than -5¶C, Comp operates over 3 hrs)
ཿ DISPLAY : STEP “1” & “3” LED Lamps are on & off continually. ୔ To Confirm Errors:
ྀ CONTROL : The system is normally operating Push “S-COOL” for continuously
ཱྀ CANCEL : When Comp is off, D-Sensor is less than -5¶C. and “TEMP” button 5 times.
F. F3 ERROR
(Return to next limit defrost time (50 min)) ୔ The Priorities of Error :
6.1- DISPLAY : STEP “1” & “2” LED Lamps are on & off continually. R1˧RT˧D1˧DR˧C1˧F3
6.2- CONTROL : At Defrost Mode, Deletion of “PRE-COOL” Mode.
6.3- CANCEL : Completion of defrost returned by D-Sensor.

44
13. PCB CONTROL FUNCTION (FR-417W, FR-417S)

<Function Key Summary Table>

t–‹Œ hŠ›–• iœ››–•GVGyŒ”ˆ™’

o–žG›–Gš›ˆ™› {Œ”—GRGzTj––“G‰œ››–•G\G›”ŒšG–™G{Œš›GrŒ GZG›”ŒšU

m–™ŠŒ‹GkŒ™–š›Gt–‹Œ o–žG›–GŒ•‹ h›Œ™Gt–‹ŒGŒ•‹šGOˆ‰–œ›GXG–œ™PG–™G{Œš›GrŒ GXG›”ŒU

kš—“ˆ  “Z”S”zTj––“’ slkGvuGOG•Gl™™–™Gkš—“ˆ P

o–žG›–Gš›ˆ™› {Œ”—G‰œ››–•GZWG›”ŒšU

wœ““Gk–ž•Gt–‹Œ o–žG›–GŒ•‹ h›Œ™Gt–‹ŒGŒ•‹šGOˆ‰–œ›GZWG–œ™šPG–™G{Œš›GrŒ GZG›”Œš

kš—“ˆ  “X”S”zTj––“’ slkGvuGOG•Gl™™–™Gkš—“ˆ P

o–žG›–Gš›ˆ™› zTj––“GRG{Œ”—G‰œ››–•G\G›”Œš

l™™–™Gkš—“ˆ  o–žG›–GŒ•‹ {Œ”—G‰œ››–•GXG›”ŒG–™Gˆ›Œ™G[G”•œ›ŒšU

kš—“ˆ  “[”S”\” slkG“Š’Œ™GO~Œ•G•–GŒ™™–™P

o–žG›–Gš›ˆ™› {Œ”—GRGzTj––“G‰œ››–•G–™G\GšŒŠ–•‹šU

kŒ”–Gt–‹Œ o–žG›–GŒ•‹ {Œ”—GRGzTj––“G‰œ››–•G–™G\GšŒŠ–•‹šU

Led lamps will be on as next steps.


kš—“ˆ 
[ “1” ˧ “2” ˧ “3” ˧ “4” ˧ “5” ˧ “1”]

44

S-ar putea să vă placă și