DESCRIPTION
Disclaimer
The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use
of this document.
Contents
1 Product Overview 1
1.1 Purpose 2
1.2 Variants 2
1.3 Hardware and Software Compatibility 3
2 Function Description 3
3 Dimensions 5
4 Power 5
5 Interfaces 5
5.1 Front Panel Devices 5
5.2 Link Settings 9
Glossary 11
1 Product Overview
1.1 Purpose
The EM-CES/63xE1/T1-LFH-AH Unit, ROA 128 3650/1 is an Expansion
Modules (EMs) that is used in conjunction with the Service Module (SM)
CES/2xSTM1-63xPDH-A, ROA 128 3722/1.
E1 backplane links connect the EM slot to two different SM slots, without the
need of using a different EM for equipment protection purpose.
• LED indicators
• Inventory EEPROM
Caution!
Because of substantial differences in the adaptation block (refer to Section
2 on page 3), EM-CES/63xE1/T1-LFH-AH Unit, ROA 128 3650/1 and
EM-63xE1-LFH Unit, ROA 128 3621 cannot be used for the same
applications. EM-CES/63xE1/T1-LFH-AH Unit, ROA 128 3650/1
must be used exclusive in conjunction with the Service Module (SM)
CES/2xSTM1-63xPDH-A, ROA 128 3722/1 and the EM-63xE1-LFH Unit,
ROA 128 3621 must be used exclusive in conjunction with the SM-63xE1
Unit, ROA 219 1105. In case the wrong EM is used, the Operator will receive
the "Installed but not expected" compliance, and the EM will be declared
out-of-service.
1.2 Variants
This unit has been introduced initially in OMS 1400 Release 3.0. No other
variant exists.
2 Function Description
The block diagram in Figure 2 shows the main functions of the unit.
-48V A
POWER SUPPLY
Tx Tranformer FROM SM
E1 #1
TO SM
Rx Isolator
X1000
Impedance Adapt.
Tranformer FROM SM
Tx
E1 #32
Isolator TO SM
Rx
Impedance Adapt.
Tx Tranformer FROM SM
E1 #1
Isolator TO SM
Rx
X1001
Impedance Adapt.
FROM SM
Tx Tranformer
E1 #32
TO SM
Rx Isolator
The balanced signal pair (two single-wire unbalanced lines), relevant to the
E1 channel, is connected to the backplane through transformer coupling
(Impedance Adaptation block).
Each SCM communicates with the SM and EM (eventually) via independent I2C
busses so that, the SM and EM (eventually) implement an I2C MUX device for
selecting those one only relevant to the active SCM resource.
Note: I2C bus is used also for accessing inventory data (stored into an
E2PROM), and other devices (if any).
The power supply module converts the -48V reference voltage from the
redounded battery lines into +3,3V and 1,8V voltages necessary for the internal
components.
3 Dimensions
4 Power
5 Interfaces
41
40
X1000
160 1
X1001
LEDs
Electrical Interfaces
The unit is provided with 2 D-Sub female connectors, named X1000 and X1001,
160 pins each one, for terminating 63 E1 signals. With reference to Figure 3,
Table 2 and Table 3 report the pin-out of these two connectors.
X1000
Pin Signal Pin Signal Pin Signal Pin Signal
36 N_OUT1 76 P_OUT30 116 N_OUT3 156 P_OUT32
37 P_OUT1 77 N_OUT30 117 P_OUT3 157 N_OUT32
38 0V 78 0V 118 0V 158 N.C.
39 N_IN1 79 P_IN30 119 N_IN3 159 P_IN32
40 P_IN1 80 N_IN30 120 P_IN3 160 N_IN32
X1001
• a 60 degree connector left open ended at the Patch Panel end (for
applications where no patch panel is used)
The cable type used depends on whether a patch panel is fitted (for
example, the Ericsson Patch Panel 32xE1-LFH-1.0/2.3, BGK 901
3811).
Glossary
AC
Active
MF
Module Fail