Sunteți pe pagina 1din 6

1. At what temperature should a motor operate?

Answer: 40C

2. At what temperature should a transformer operate?


Answer: 50C

3. When connected Earthing and Earth continuity conductor to one earth electrode,
it shall be lable at or immediately adjacent to the point at which the connection is
made.
Answer: earthing conductor, do not disconnect

4. Buried plate electrode – does it have more advantages over strip electrode?
Answer: no

5. Should a flexible metal circuit be used as earth continuity conductor?


Answer: no

6. Why most portable appliance doesn’t use earth?


Answer: most portable appliance use double installation.

7. What kind of switches should be install in petrol stores?


Answer: flame proof and water resistance.

8. The room in which a private generating plaint installed should be of such that the
Plant can be easily and adequately maintain.
Answer:
 Well ventilated
 Provide with exhaust pipe or duck to discharge exhaust fumes from the
prime mover to the outside.

9. Why is it necessary to earth a D C generator?


Answer: to avoid circulating current.

10. Do you have step up autotransformer?


Answer: yes. Should not be connected to an installation obtaining it supply form
a system in which none of the poles of the supply is connected t earth.

11.Why is it that most hospital equipment is not?


Answer: I would not want any leakage current to flow .So I would use double
Insulation

12.What are the two (2) types of voltage use on lamp holder?
Answer: Extra low voltage and low voltage
13.If there is a heating system with two (2) heater.
How would you achieve
Answer:
Low  series them
Medium  One switch to neutral
High  parallel both

14.How does current flow?


Answer: Current (I) flow from Negative to positive, while
Conversional Current (I) flows from positive to negative

15. What is the per pose of catenaries wire


Answer: It is use as a support wire from building to building.
A long length of same should be earthed. Short length does
Not require earthing.

16.What is the two-meter rule?


Answer: It avoids danger of a voltage of 415 a paring
Between appliance, switches and plugs

17.Why do we do load test on transformer


Answer: To check the voltage ratio

18.what happen when a motor or a transformer is placed very high?


Answer: Efficiency of both will drop as it becomes more heated.

19.What happen when a 60-cycle motor is connected to a 50 cycle


System?
Answer: The speed higher
Current get higher
Heat increase
Life span reduce

20.In a ring circuit with plugs protected by a 5 amps fuse in an area


Not exceeding 1000 square meter. How much can be used?
Answer: Any Amount
For any other premises
Six

21.How many times a transformer should be earthed?


Answer: One

22.One which side should it be earthed


Answer: One the secondary side
23. How many earthing should be on a A.C generator?
Answer: multiple

24.How many earthing point should be on a DC generator?


Answer: One

25.How does the voltage operate earthing leakage circuit?


Breaker operate
Answer: When there is voltage between live and nuetrol

26.How does the current operate circuit breaker operates?


Answer: When a circuit flows in the trip coil

27.What is the minimum space between a switch and a door


Jam?
Answer: 6 inches

28.How much volts it takes to operate an earth leakage circuit


Breaker?
Answer: 40 volts up

29.Should caravan be earthed?


Answer: No

30.The load on caravan should not exceed how much amps?


Answer: 15 amps

31.What type of wiring should be used on caravan?


Answer: Tuff rubber sheeted three-core flex able
Cable or cord.

32.What kind of plug supply should be used to supply current?


To caravan?
Answer: Weather proof

33.Every motor should be provided with effective means


Answer: Stop and start

34.Every motor provided with means to prevent auto mastics


Restart after stopping?
Answer: true or false
35.What is ampacity?
Answer: Ability of wire to carry current.

36. What is a tandem plug?


Answer: it is an adopter

37.What can cause the a. c generator to speed up?


Answer: the governed

38. Name two ways of protecting a generator.


Answer: circuit breakers and earthing

39. What are the main things of can earn when choosing generator?
Answer: supply voltage and total load.

40. What is the purpose of a rheostat in a d/c motor?


Answer: it is to control the speed.

41. What type of start would you use for a 200 hp wound roto motor
Answer: you would use a three-phase roto resistance starter.

42. What type of start would you use for a 500 hp three-phase motor?
Answer: you would use autotransformer or soft strant method.

43. How would you get 190 volt from a 415-v supply?
Answer: it’s not possible.

44. What type of supply gives a higher voltage more readily?


Answer: a/c supply

45. How would you get 415 volts supply to give 22ov/120v?
Answer: Autotransformer.
46. How would you reverse the rotation of a single-phase motor?
Answer: you can exchange rotation by changing the current flow and the
starting winding, also forward reverse selector switch.

47: what type of wimmy system would you use on a workshop garage/
Answer: pvc- swa or xlpe

48: Describe double case motor?


Answer: It has an inner and an outer case. The inner cases have low resistance
while the outer have high resistance. It starts an inner case and runs an the outer.

49. What is earthing objective?


Answer: it is to ensure that all none current-carrying parts of an installation is
connected to the general mass of earth.

50. Where is it mandatory to place lightening arrestor?


Answer: cinemas, hotels, churches and schools. And building that has over fifty
people at any time.

51. Where is an installation you do not make a joint?


Answer: between pothead and meter socket and in conduits.

52. How would you approach a maintenance work in a factory?


Answer: main distribution board for source.

53. Where in the meter socket in an edusam delta supply do you find the 190-volt
leg?
Answer: facing meter socket it must be to the extreme right.

54. How do you labeled earth rod connection?


Answer: Danger earth electrodes don’t remove. Tag should be made of
waterproof material or be laminated.

55. What are the (3) criteria in regards to the installation of meter socket?
Answer: height 5,6 to 6,6” (measure from center). 100 feet from service provider
and 5 feet from boundary.

56. If you have 415 volts supply and you need to light up the circuit with 220 volts.
What kind of switch and breaker is used to control the circuit?
Answer: single pole switch, single pole circuit breaker.
Because it will be connected one phase too neutral.

57. At what height must a switch be installed?


Answer: 4,6

58: at what height must a flush plug be installed?


Answer: 18

59. Where should an electrical outlet not be erected?


Answer: under sink, not less than size feet away from pipe taps or any path
they’re of
60. What is a half set?
Answer: it’s a bond, which is used to center apparatus such as handy boxes;
panels meter socket and octagonal boxes.

61.How do you change the rotation of electric motor?


Answer: Inter change any two phases

62.At what dept must a 30 feet pole be planted?


Answer: 1/10 height  two feet

63.If a doctor electricity supply got disconnect and


He approaches you as licensed electrician for anistance
To have it reconnected. What would be your response?
Answer: Go get in touch with the service provider

64.How do you prepare yourself for electrical inspection


as it relates to circuit?
Answer: Make sure no bulbs are in socket, switches must
be in off position as it regards to flows ent lamp which are
inductive lad these should not be connected.

65.In terms of what would you ensure that you have in place
for decking inspection?
Answer: pipes are properly secured to the steel or decking
And the octagonal boxes are properly nail to the ply and stuffed
With cement bag

66.What is arching?
Answer: potentian difference between two contacts.

67. Name some faults that corrosion causes?


Answer: low voltage, higher resistance and high current.

S-ar putea să vă placă și