Process Industry Practices


Insulation

PIP INIC1000
Cold Insulation Installation Details
PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES

In an effort to minimize the cost of process industry facilities, this Practice has
been prepared from the technical requirements in the existing standards of major
industrial users, contractors, or standards organizations. By harmonizing these technical
requirements into a single set of Practices, administrative, application, and engineering
costs to both the purchaser and the manufacturer should be reduced. While this Practice
is expected to incorporate the majority of requirements of most users, individual
applications may involve requirements that will be appended to and take precedence
over this Practice. Determinations concerning fitness for purpose and particular matters
or application of the Practice to particular project or engineering situations should not
be made solely on information contained in these materials. The use of trade names
from time to time should not be viewed as an expression of preference but rather
recognized as normal usage in the trade. Other brands having the same specifications
are equally correct and may be substituted for those named. All Practices or guidelines
are intended to be consistent with applicable laws and regulations including OSHA
requirements. To the extent these Practices or guidelines should conflict with OSHA or
other applicable laws or regulations, such laws or regulations must be followed.
Consult an appropriate professional before applying or acting on any material
contained in or suggested by the Practice.

This Practice is subject to revision at any time.

© Process Industry Practices (PIP), Construction Industry Institute, The


University of Texas at Austin, 3925 West Braker Lane (R4500), Austin,
Texas 78759. PIP member companies and subscribers may copy this Practice
for their internal use. Changes, overlays, addenda, or modifications of any
kind are not permitted within any PIP Practice without the express written
authorization of PIP.

Note (added February 2002): PIP INIC1000, Cold Insulation Installation Details, may
incorporate drawings and other information previously published in standards owned and
copyrighted by the Midwest Insulation Contractors Association (MICA). These are printed with
the express permission of MICA.

PRINTING HISTORY
September 1999 Issued September 2006 Technical Revision
February 2002 Editorial Revision February 2007 Editorial Revision

Not printed with State funds


EDITORIAL REVISION
February 2007

Process Industry Practices


Insulation

PIP INIC1000
Cold Insulation Installation Details

Table of Contents

1. Introduction................................. 2
1.1 Purpose............................................ 2
1.2 Scope ............................................... 2

Data Sheets
INIC0001 General Arrangement - Piping INIC0050 Vertical Vessels with Outside
Insulation Diameters over 900 (36")
INIC0002 Piping - Layered Insulation INIC0051 Vertical Vessels with Outside
INIC0003 Piping - Vertical Insulation Support Diameters 900 (36") and Less
Single Layer INIC0052 Vessel Head
INIC0004 Piping - Vertical Insulation Support INIC0054 Vertical Vessel Bottom Head
Multiple Layers Insulation
INIC0005 Piping - Single Layer Horizontal INIC0055 Nozzle
Contraction Joint INIC0056 Vessel Stiffener Insulation Detail
INIC0006 Piping - Multiple Layer Horizontal INIC0059 Typical Clip Details
Contraction Joint INIC0061 Lap Seam Detail
INIC0008 Piping - Flange Insulation INIC0062 Horizontal Vessels w/Outside
INIC0009 Piping - Insulation Connections Diameters over 2400 (96")
INIC0010 Valves with Extended Bonnets INIC0063 Application of Metal Gores on
INIC0011 Valves without Extended Bonnets Horizontal Vessel Heads
INIC0064 Head Insulation Securement

Process Industry Practices Page 1 of 2


PIP INIC1000 EDITORIAL REVISION
Cold Insulation Installation Details February 2007

1. Introduction

1.1 Purpose
This Practice provides installation details for cold insulation systems.

1.2 Scope
This practice provides details for installing cold insulation systems on piping,
valves, horizontal and vertical vessels, and heat exchangers.

Page 2 of 2 Process Industry Practices


PROCESS INDUSTRY PRACTICES
INIC0001
COLD INSULATION INSTALLATION DETAILS
DATE 02-21-07

PAGE 1 OF 1
GENERAL ARRANGEMENT - PIPING INSULATION
INIC1000

INSULATION FOR HANGER

INSULATION
FOR PIPE TEE

VAPOR BARRIER
t
3T

SUPPORT RING

PIPE INSULATION
SECUREMENT
PIPE INSULATION

BAND

WEATHERPROOF JACKETING

VERTICAL PIPE
INSULATION

VERTICAL INSULATION
SUPPORT RING

(SEE INIC0003/04)

INSULATION
FOR ELBOW

(MITERED OR
BAND
PRE-FORMED)

VAPOR 300
BARRIER SUPPORT RING
(12")

JACKET OVERLAP
t
WEATHERPROOFING JACKET 3T

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0002
COLD INSULATION INSTALLATION DETAILS
DATE 02-21-07

PAGE 1 OF 1

PIPING-LAYERED INSULATION
INIC1000

SINGLE-LAYER INSULATION

JOINT SEALER

(TYP)
2
A/ P.
TY
A
0 P.
20 TY
)
(8" OX. A
PR
AP P.
TY
2
A/ P. SECUREMENT
TY

A = APPROX. 200 (8") FOR 600 (2') LONG


INSULATION SEGMENTS

A = APPROX. 300 (12") FOR 900 (3') LONG


INSULATION SEGMENTS

STAGGER CIRCUMFERENCIAL JOINTS

MULTI-LAYER INSULATION (TYPICAL)

2
A/ .
/2
N
MI
A
JOINT SEALER N.
MI
(TYP)
(OUTER LAYER ONLY)

A
P.
TY
A
X. A
0 P RO
30 AP P .
-
2")
25 TY
2
-1 X. A/2
(9" PRO TY
P.
AP

STAGGER LONGITUDINAL

JOINTS 50 (2") (MINIMUM)

SECUREMENT

(3)PER SECTION

2
A/
N.
MI

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0003
COLD INSULATI0N INSTALLATION DETAILS
DATE 02-21-07

PAGE 1 OF 1
PIPING-VERTICAL INSULATION SUPPORT
SINGLE LAYER INIC1000

T t

WEATHERPROOF
JACKETING
SUPPORT RING

(BOLTED OR
SHOP WELDED)
METALLIC COVER
FOR CONTRACTION
JOINT

ADHESIVE

(TYP - INDICATED
BY HEAVY LINES)

FLEXIBLE SEAL

1.2 (0.05") BUTYL


RUBBER SHEET 25 (1")
(TYP)
BLANKET INSULATION
FOR CONTRACTION
JOINT
VAPOR BARRIER

T = SINGLE LAYER THICKNESS OR THICKNESS OF INNER LAYER(S)


t = 2/3t, 25 (1") MIN. FOR PIPING AND 40 (1 1/2") FOR EQUIPMENT

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0004
COLD INSULATI0N INSTALLATION DETAILS
DATE 02-21-07

PAGE 1 OF 1
PIPING-VERTICAL INSULATION SUPPORT
MULTIPLE LAYERS INIC1000

VAPOR BARRIER

SUPPORT RING WEATHERPROOF

(BOLTED OR SHOP JACKETING

WELDED)
BANDS
(1")
25

USE 16 GAGE
STEEL " Z" CLIP
(6")
150

DOUBLE LAYER OF
INSULATION SHOWN

(OTHER LAYERS SIMILAR)

BUTYL RUBBER SLEEVE KEEP BANDS CLEAR


OF CONTRACTION JOINT
(NOT REQUIRED WITH
MEMBRANE TYPE VAPOR

BARRIER) LOCATE
25(1") BLANKET INSULATION
FOR CONTRACTION JOINT
BELOW
CONTRACTION
(FOLDED IN HALF) (TYPICAL)
JOINT S-CLIP

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0005
COLD INSULATI0N INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1
PIPING - SINGLE LAYER HORIZONTAL
CONTRACTION JOINT INIC1000

ADHESIVE (TYPICAL - INDICATED


BY HEAVY LINES)

WEATHERPROOF JACKETING BLANKET INSULATION FOR


CONTRACTION JOINT

25 25

(1") (1")
75 75 75

(3") (3") (3")

VAPOR BARRIER
METALLIC CONTRACTION
JOINT COVER

FLEXIBLE SEAL

1.2 (0.050") BUTYL


RUBBER SHEET

T = SINGLE LAYER THICKNESS OR THICKNESS OF INNER LAYER(S)

t = 2/3T, 25 (1") MIN. FOR PIPING AND AND 40 (1 1/2") FOR EQUIPMENT

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0006
COLD INSULATI0N INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1
PIPING-MULTIPLE LAYER
HORIZONTAL CONTRACTION JOINT INIC1000

FLEXIBLE SEAL

1.2 (0.050") BUTYL


RUBBER SHEET

WEATHERPROOF JACKETING

VAPOR BARRIER

T1 OUTER LAYER

T INNER LAYER

25 25

(1") (1")
75 75 75

(3") (3") (3")

ADHESIVE (TYPICAL - INDICATED


BY HEAVY LINES)

BLANKET INSULATION FOR


CONTRACTION JOINT

T = THICKNESS OF INNER LAYER(S)

T1 = OUTER LAYER THICKNESS

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0008
COLD INSULATION INSTALLATION DETAILS DATE 02-22-07

PAGE 1 OF 1

PIPING-FLANGE INSULATION
INIC1000

WEATHERPROOF JACKETING

BAND (TYPICAL)
VAPOR BARRIER

JOINT SEALER

VAPOR STOP
MULTI-LAYER
SEE DETAIL 1

VAPOR BARRIER
STUD LENGTH PLUS 25 (1")
PIPE INSULATION (BOTH SIDES OF FLANGE)

100

(4")

VAPOR STOP

VAPOR BARRIER

DETAIL 1
WEATHERPROOF JACKETING
MULTI-LAYER

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0009
COLD INSULATION INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1

PIPING-INSULATION CONNECTIONS
INIC1000

BRANCH CONNECTION

(NON-PREMOLDED)

VAPOR BARRIER

WEATHERPROOF JACKETING
6 (1/4") CAULKING BEAD

JOINT SEALER

PIPE INSULATION
VAPOR BARRIER

END CAP

WEATHERPROOF
JACKETING

BLOCK INSULATION

WEATHERPROOF
JACKETING

VAPOR BARRIER

BAND
BAND

WEATHERPROOF
JACKETING

BLOCK INSULATION

WEATHERPROOF
JACKETING

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0010
COLD INSULATION INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1

VALVES WITH EXTENDED BONNETS


INIC1000

NOTES: ALL JOINTS SHALL BE FILLED WITH JOINT SEALER

VALVE MANUFACTURER TO MARK VALVE BONNET TO SHOW INSULATION TERMINATION / LIMIT

VAPOR STOP
CAULK

VAPOR BARRIER

METAL JACKETING

VAPOR STOP

STUD
BANDS (TYP)
LENGTH PLUS 25 (1") MIN

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0011
COLD INSULATION INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1

VALVES WITHOUT EXTENDED BONNETS


INIC1000

NOTE
ALL JOINTS
SHALL BE FILLED WITH
JOINT SEALER

CAULK

VAPOR BARRIER
WEATHERPROOF JACKETING

VAPOR STOP

(TYPICAL)

BANDS (TYP)
PIPE INSULATION

STUD

LENGTH PLUS 25 (1") MIN

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0050
COLD INSULATI0N INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1
VERTICAL VESSELS

WITH OUTSIDE DIAMETERS OVER 900 (36") INIC1000

SMOOTH JACKET

SEGMENTS
TOP HEAD NOZZLES (SEE INIC0055)
HEAD LAP SEAM HEAD INSULATION

(SEE INIC0061) (SEE INIC0052)

VAPOR BARRIER

WEATHERPROOF JACKETING

(TYPICAL)
S - CLIP
BANDS
(SEE INIC0059)

INSULATION

INTERMEDIATE INSULATION

SUPPORT RING

(BY VESSEL FABRICATOR)


STIFFENER RING

(SEE INIC0056)
BANDS ON

300 (12") CENTERS

LAP 50 (2") MINIMUM

HORIZONTAL NOZZLE
LAP 2 1/2 CORRUGATIONS
OR 50 (2") MINIMUM (SEE INIC0055)
FOR FLAT JACKETING

BANDS

BAND SUPPORT J - CLIP


BOTTOM HEAD AND
(SEE INIC0059)
INSIDE SKIRT INSULATION

(SEE INIC0054)

NOTE: FILL ALL INSULATION JOINTS


WITH JOINT SEALER

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0051
COLD INSULATION INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1
VERTICAL VESSELS WITH OUTSIDE

DIAMETERS 900 (36") AND LESS INIC1000

BLOCK INSULATION

VERTICAL NOZZLE
(INIC0055)
LOCK FORMED SEAM

WEATHERPROOF JACKETING
SECTIONAL OR SEGMENTAL
LAPPED MINIMUM 50 (2") BOTH WAYS
PIPE INSULATION

VAPOR BARRIER

S - CLIP (INIC0059)

HORIZONTAL NOZZLE
(INIC0055)

BANDS ON 300 (12")


CENTERS

J - CLIP (INIC0059)

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0052
COLD INSULATION INSTALLATION DETAILS DATE 02-22-07

PAGE 1 OF 1

VESSEL HEAD
INIC1000

VAPOR BARRIER

BAND

ELASTOMERIC FOAM BACKING LAYER,


SEE INIC0061

WEATHERPROOF JACKETING

FASTENERS ON 150 (6") CENTERS (MAX)


AND ONE FASTENER (MIN) PER METAL
HEAD GORE (DO NOT PUNCTURE

VAPOR BARRIER)

WEATHERPROOF JACKETING

(SHOWN CORRUGATED)

BAND

VAPOR BARRIER

WEATHERPROOF JACKETING

50 (2") MINIMUM OVERLAP


W/ S - CLIP

INTERMEDIATE SUPPORT RING

25 (1") THICK BLANKET INSULATION


FOR CONTRACTION JOINT TYPICAL
AT EACH SUPPORT RING

BUTYL RUBBER SLEEVE (TYP)

50

(2")

" S" CLIP


NOTE : MECHANICAL INTERLOCKING SEAMS WITHOUT SCREWS
OR ELASTOMETRIC BACKING MAY BE SUBSTITUTED
IF APPROVED BY PURCHASER

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0054
COLD INSULATION INSTALLATION DETAILS DATE 02-22-07

PAGE 1 OF 1
VERTICAL VESSEL
BOTTOM HEAD INSULATION INIC1000

10 (3/8") DIA. ROUND BAR WITH


VAPOR BARRIER
25 (1") STAND-OFF CLIPS SPACED
ON 600 (24") CENTERS
WEATHERPROOF JACKETING
(ONE PER LAYER)

CENTER

NOZZLE
10 (3/8") DIA. FLOATING
BAND ANCHOR RING 4t [610 (24") MINIMUM]
(ONE PER LAYER)

VAPOR BARRIER

VAPOR BARRIER VAPOR STOP

BOTTOM SUPPORT

VAPOR STOP VAPOR STOP

SUPPORT RING SUPPORT RING


SKIRT

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0055
COLD INSULATION INSTALLATION DETAILS DATE 02-22-07

PAGE 1 OF 1

NOZZLE
INIC1000

WEATHERPROOF
JACKETING

VAPOR STOP

VAPOR BARRIER

STUD LENGTH

PLUS 25 (1") MIN.


VAPOR STOP

VAPOR BARRIER
VAPOR BARRIER
WEATHERPROOF
JACKETING
HEAD BAND

FLOATING RING

VAPOR STOP VESSEL HEAD

t = THICKNESS REQUIRED FOR PIPING

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0056
COLD INSULATION INSTALLATION DETAILS DATE 02-22-07

PAGE 1 OF 1

VESSEL STIFFENER INSULATION DETAIL


INIC1000

INSULATION

WEATHERPROOF JACKETING

BAND

WEATHERPROOF JACKETING

(SLOPE TO SHED WATER)


150 (6") LAP
(TYP)

BANDS

STIFFENER

VAPOR BARRIER

OUTER BLOCK

50 (2") THICK
(MAXIMUM)

BANDS

BAND
VAPOR BARRIER
VESSEL I.D.

BAND

WEATHERPROOF JACKETING

NOTE : BODY FLANGE INSULATION SIMILAR TO ABOVE.

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0059
COLD INSULATION INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1

TYPICAL CLIP DETAILS


INIC1000

20
(3/4")

50
(2")
25
(1")

NOTE:

1. USE 20 (3/4") x 0.5 (0.020") (MINIMUM)


STAINLESS STEEL BANDS.
25
(1") 2. LOCATE 610 (24") APART.
3. MINIMUM OF (2)-CLIPS PER SHEET.

S-CLIP

BAND LOOP

SCREW AT RIDGE OF CORRUGATED


WEATHERPROOF JACKETING.

(DO NOT PENETRATE VAPOR BARRIER)

STAINLESS STEEL J-CLIP

JACKET BAND

NOTE:

1. USE 12 (1/2") x 0.5 (0.020") (MINIMUM)


STAINLESS STEEL BANDS.
2. LOCATE AS NEEDED.

J-CLIP

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0061
COLD INSULATION INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1

LAP SEAM DETAIL


INIC1000

WEATHERPROOF
JACKETING
SHEET METAL SCREW

LOCATED ON 150 (6")


CENTERLINE (DO NOT
PUNCTURE VAPOR BARRIER)

20 (3/4") ELASTOMERIC
FOAM BACKING
LAYER

VAPOR BARRIER

INSULATION

NOTE : MECHANICAL INTERLOCKING SEAMS WITHOUT SCREWS


OR ELASTOMETRIC BACKING MAY BE SUBSTITUTED
IF APPROVED BY PURCHASER

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0062
COLD INSULATI0N INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1
HORIZONTAL VESSELS

W/ OUTSIDE DIAMETERS OVER 2400 (96") INIC1000

CIRCUMFERENTIAL SUPPORT RING VERTICAL NOZZLE BANDS FOR


FOR BANDING INSULATION (INIC0055) JACKETING

BLOCK
SMOOTH JACKET
INSULATION 300 SHELL/HEAD JOINT
SEGMENTS
(12") (INIC0063)
(MAX)

HORIZONTAL NOZZLE

(INIC0055)

LAP SEAM WEATHERPROOF FABRIC


(INIC0061) REINFORCED MASTIC

(WHEN SPECIFIED)
BANDS FOR INSULATION

WEATHERPROOF JACKETING
VAPOR BARRIER
LAPPED 50 (2") MINIMUM,
BOTH WAYS

NOTE : INSULATION SHALL EXTEND DOWN ON TO SADDLE


A DISTANCE OF 4T FROM LOW POINT OF VESSEL

SHELL, LEAVING BOTTOM 150 (6") MIN UNINSULATED

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICE
INIC0063
COLD INSULATION INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1
APPLICATION OF METAL GORES
ON HORIZONTAL VESSEL HEADS INIC1000

300 INSULATION SUPPORT BAND

(12")
(MAX)
BANDS (TYPICAL)
[300 (12") MAX. CENTERS
@ KNUCKLE RADIUS]

LAP SEAMS

(INIC0061)

INSULATION

GORE

SEALANT

METAL JACKET

BAND 150 (6") OR MORE

JACKET BANDS (TYP)

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE


PROCESS INDUSTRY PRACTICES
INIC0064
COLD INSULATI0N INSTALLATION DETAILS
DATE 02-22-07

PAGE 1 OF 1
HEAD INSULATION SECUREMENT
INIC1000

300 (MAX)
(12")
(TYP)

(FOUR SHOWN)

CIRCUMFERENTIAL
BANDS

FLOATING RING

NUMBER OF TAB ANCHOR CIRCUMFERENTIAL


BANDS REQUIRED IS DETERMINED AS
FOLLOWS N = 2 + VESSEL O. D. IN FEET.

(MIN OF 3)

DIMENSIONS ARE GIVEN IN METRIC - MILLIMETERS. IMPERIAL DIMENSIONS

IN PARENTHESES ARE IN FEET AND/OR INCHES, UNLESS NOTED OTHERWISE