Slow cooling protocol improves fatigue life of


zirconia crowns

Vitor G. Paula a , Fabio C. Lorenzoni d , Estevam A. Bonfante a,∗ ,


Nelson R.F.A. Silva b , Van P. Thompson c , Gerson Bonfante a
a Department of Prosthodontics, University of São Paulo – Bauru College of Dentistry, Bauru, SP, Brazil
b Department of Restorative Dentistry, Federal University of Minas Gerais, UFMG, Belo Horizonte, MG, Brazil
c Department of Biomaterials, Biomimetics and Biophotonics, King’s College London, Guy’s Hospital, London, United

Kingdom
d Department of Prosthodontics, UNIGRAN University, Dourados, MS, Brazil

a r t i c l e i n f o a b s t r a c t

Article history: Objective. To compare the fatigue life and damage modes of zirconia crowns fabricated with
Received 2 September 2013 and without framework design modification when porcelain veneered using a fast or slow
Received in revised form cooling protocol.
22 December 2013 Methods. Composite resin replicas of a first molar full crown preparation were fabricated.
Accepted 27 October 2014 Zirconia copings were milled as conventional (0.5 mm even thickness, Zr-C, n = 20,) or mod-
Available online xxx ified (lingual margin of 1.0 mm thickness, 2.0 mm height connected to two proximal struts
of 3.5 mm height, Zr-M, n = 20). These groups were subdivided (n = 10 each) according to the
Keywords: veneer cooling protocol employed: fast cooling (Zr-CFast and Zr-MFast) and slow cooling
Ceramics (Zr-CSlow and Zr-MSlow). Crowns were cemented and fatigued for 106 cycles in water. The
Fatigue number of cycles to failure was recorded and used to determine the interval databased 2-
Weibayes parameter probability Weibull distribution parameter Beta (ˇ) and characteristic life value
Cooling rate Eta ().
Fractography Results. 2-parameter Weibull calculation presented ˇ = 5.53 and ˇ = 4.38 for Zr-MFast and Zr-
Zirconia CFast, respectively. Slow cooled crowns did not fail by completion of 106 cycles, thereby
Weibayes calculation was applied. Increased fatigue life was observed for slow cooled crowns
compared to fast cooled ones. Groups Zr-MFast and Zr-MSlow presented no statistical differ-
ence. Porcelain cohesive fractures were mainly observed in fast cooled groups. Slow cooled
crowns presented in some instances inner cone cracks not reaching the zirconia/veneer
interface.
Significance. Improved fatigue life in tandem with the absence of porcelain fractures were
observed in slow cooled crowns, regardless of framework design. Crowns fast cooled chiefly
failed by porcelain cohesive fractures.
© 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.


Corresponding author at: Alameda Octávio Pinheiro Brisola 9-75, 17.012-901 Bauru, SP, Brazil. Tel.: +55 14 98153 0860;
fax: +55 14 3234 5805.
E-mail address: estevamab@gmail.com (E.A. Bonfante).
http://dx.doi.org/10.1016/j.dental.2014.10.005
0109-5641/© 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
2 d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx

a year later it was modified and crowns should be kept into


1. Introduction the closed furnace up to temperature reaching 450 ◦ C, slightly
below the Tg (490 ◦ C) of the veneer porcelain [28].
Over the past ten years several in vitro [1–5] and clinical stud- Another topic that has frequently been revisited is frame-
ies [6,7] have attempted to document and understand the work design modifications in Y-TZP restorations [4,14,29].
nature of porcelain veneer cohesive fractures in all-ceramic Clinical evaluations have suggested that porcelain chipping
restorations, specially yttria-tetragonal zirconia polycrystals is frequently associated with areas without appropriate porce-
(Y-TZP) [6,7]. Besides issues related to manufacturing process lain support (proximal areas) [14,15,30]. This empirical concept
(i.e., porosities and micro-structural defects) [8], chipping has relies on the fact that the porcelain veneer should have an
been suggested to be strongly related with; residual thermal even thickness, of no more than 2 mm, and be supported by
stress [9–12], coefficient of thermal expansion mismatches [1], the core [31]. Although framework design modifications have
poor framework design [3,4,13–15], and others [12]. shown to decrease chipping rates in clinical trials [15,32,33]
Changes in the porcelain physical properties (during the no control groups (i.e., even thickness framework) have been
transition from the visco-elastic to solid state) when it is included, hindering a more comprehensive understanding
cooled down from the sintering temperature to room tem- between framework design modification and chipping [15,32].
perature take place in every firing cycle [16,17]. As a result, In light of the aforementioned information, this study
non-uniform residual thermal stresses may be produced sought to evaluate the fatigue life and failure modes of Y-TZP
throughout the porcelain veneer as a function of cooling molar crowns fabricated with two different porcelain veneer
rates [18,19]. Such residual stress may be induced within the cooling protocols with and without framework design modifi-
porcelain veneer either by thermal expansion mismatches cation. The following null hypotheses were tested: (1) cooling
or by the temperature gradients produced during cooling or protocols during glazing will not improve the fatigue life of Y-
both [12,17]. Similarly to tempered glass, during a fast cool- TZP systems and (2) framework design modification will not
ing process the outer crown surface becomes solid first and improve the fatigue life of Y-TZP crown systems, irrespective
starts to contract inducing a compressive stress. However, of cooling rate.
while the inner surface is still in a visco-elastic state and
at high temperature, leading to high tensile stress when the
system reaches room temperature [12,17,19]. This process is 2. Materials and methods
expected given that the porcelain veneer inner bulk remains
in a temperature above its glass-transition temperature (Tg ), 2.1. Sample preparation
leading to the gradient temperature (difference between the
inner and outer temperature) [12]. As a consequence, resid- A plastic maxillary first molar positioned in a mannequin
ual thermal stresses are held within the porcelain veneer (Plastic mannequin tooth – MOM, Marilia, SP, Brazil) was pre-
[9,12,20], also known as tempering. In addition, Y-TZP shows a pared to receive a full crown by reducing the axial walls by
low thermal diffusivity (thermal conductivity of 2 W m−1 K−1 1.5 mm, the occlusal surface by 2.0 mm and shoulder margin
whereas metals vary from 100 to 300 W m−1 K−1 ) [21,22], (1.2 mm of thickness) with rounded internal angles. After-
which may increase the thermal gradient intensity within wards, 40 composite resin replicas were obtained from a vinyl
veneer porcelain [9,12,20,23]. Therefore, the multifaceted role polysiloxane impression (Express – 3M ESPE, St. Paul, MN,
of the above factors, has been speculated as potential sources USA) of the prepared tooth, which was incrementally (2.0 mm
related to high Y-TZP chipping rates reported in the literature of thickness) packed with composite resin (Z100 – 3M ESPE,
[5,8,10,12,23]. St. Paul, MN, USA) and light-cured (Ultralux, Dabi Atlante,
Recently, efforts have been devoted to the reduction of Ribeirão Preto, SP, Brazil) according to manufacturer’s instruc-
residual thermal stresses in Y-TZP restorations by managing tions. All resin tooth replicas were stored in distilled water
the rates of cooling [9,10,24,25]. It has been reported that over- for at least 30 days to minimize dimensional changes during
all thermal gradients within the porcelain veneered to Y-TZP testing [34]. Each replica was vertically positioned in 25 mm
decreased when a slow cooling protocol was used [23,26]. Also, diameter PVC tubes and potted with acrylic resin (Jet, Clássico
thermodynamic analysis performed in molar crowns showed Artigos Odontológicos, São Paulo, SP, Brazil). The preparation
that different results may be achieved as a function of cooling finish line was maintained 2 mm above the potting sur-
protocols [23]. It has been shown that slow cooling (the furnace face. Stone dies were acquired from polyether impressions
door opened when the temperature was below the porcelain (Impregum F – 3M-ESPE, St. Paul, MN, USA) of each resin-tooth
veneer Tg ) produced a small temperature variation between replica and sent to a dental laboratory.
the inner and outer surfaces of crowns and, more important, Stone dies were randomly divided in 2 groups (n = 20, each)
it decreased the residual thermal stresses within the veneer according to framework design, as: conventional (Zr-C) or
layer [23]. However, to date few attempts regarding the influ- modified design (Zr-M). Subsequently, each group was subdi-
ence of cooling rate on the fatigue life of Y-TZP crowns are vided in two subgroups (n = 10) according to thermal cooling
available. protocol as: fast cooling protocol (Zr-CFast and Zr-MFast) and
Most manufacturers of porcelain veneers for Y-TZP restora- slow cooling protocol (Zr-CSlow and Zr-MSlow).
tions have modified their firing guidelines, advocating that Frameworks were milled from pre-sintered Y-TZP blocks
technicians adopt a slow cooling rate protocol. In 2009 for (e.max ZirCAD, shade MO 0, block size 15C – Ivoclar Vivadent,
example, one manufacturer recommended that the furnace Schaan, Liechtenstein) and sintered in the furnace (Sintra-
was opened soon after the end of the firing cycle [27], and mat, Ivoclar Vivadent AG, Schaan, Liechtenstein) at 1500 ◦ C

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx 3

Fig. 1 – Proximal view of (a) standard and (b) modified core designs before veneering with porcelain.

Table 1 – Programat® EP 3000 – Firing program table


(Ivoclar Vivadent) – March 2010 [31].
Program ZirLiner e.Max Ceram

Stand-by temperature 403 C 403 ◦ C
Stand-by time 4 min 4 min
Temperature increase 40 ◦ C/min 40 ◦ C/min
Holding temperature 960 ◦ C 750 ◦ C
Holding time 1 min 1 min
Vacuum on 450 ◦ C 450 ◦ C
Vacuum off 959 ◦ C 749 ◦ C
Opening furnace 960 ◦ C 750 ◦ C
Cooling rate – –

for 8 h. Zr-C cores were manufactured with an even thick-


ness of 0.5 mm. For Zr-M cores, a lingual margin (thickness of
1.0 mm with 2.0 mm height) connected to two proximal struts
of 3.5 mm height were added to an even thickness of 0.5 mm,
as described previously [3] (Fig. 1).
All Y-TZP cores were veneered with porcelain (IPS e.max
Ceram, shade Transpa Clear – Ivoclar Vivadent AG, Schaan,
Liechtenstein) and sintered in a ceramic furnace (Progra-
mat EP3000 – Ivoclar Vivadent, Schaan, Liechtenstein). The
hand-layering process was performed in accordance with the
manufacturer’s recommendation, starting with one liner firing
(ZirLiner – Ivoclar Vivadent AG, Schaan, Liechtenstein) fol-
lowed by firing two layers of porcelain. Finally, the crowns
were manually finished and polished before the glaze fir-
ing. The firing schedule of liner and veneering porcelain are
shown in Table 1 and Fig. 2A. A silicone matrix (Zetalabor
– Zhermack, Badia Polesine, Rovigo, Italy) of the unprepared
plastic mannequin tooth was used to guide and standardize
the porcelain veneer contour. The occlusal and axial surfaces
showed approximately 1.5 and 1.0 mm of thickness, respec-
tively. The glaze layer (Glaze Paste and Stain Liquid Long Life,
IPS e.Max Ceram – Ivoclar Vivadent AG, Schaan, Liechtenstein)
was applied onto the porcelain surface and treated according
to one of the following cooling protocols (Fig. 2B and Table 2):

Fig. 2 – (A) Programat® EP 3000 – Firing program (Ivoclar


• Fast cooling: after the end of the glaze firing cycle, the fur-
Vivadent) – March 2010 [28]. (B) Glaze firing program.
nace head was opened. Then, crowns were immediately
taken out from the mesh-tray to the bench, leading to cool

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
4 d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx

the ˇ of the counter group’s distribution. Weibayes is a one-


Table 2 – Glaze firing program table.
parameter Weibull analysis technique developed to “solve
Program Fast cooling Slow cooling problems when traditional Weibull analysis has large uncer-
Stand-by temperature 403 ◦ C 403 ◦ C tainties or cannot be used because there are no failures” [36].
Stand-by time 6 min 6 min “A basic assumption governing the accuracy of Weibayes anal-
Temperature increase 60 ◦ C/min 60 ◦ C/min
ysis and its associated test regimens is that the value of the
Holding temperature 725 ◦ C 725 ◦ C
Weibull shape parameter (ˇ) is known or can be reasonably
Holding time 1 min 1 min
Vacuum on 450 ◦ C 450 ◦ C estimated”. “Knowledge of ˇ can be derived from historical
Vacuum off 724 ◦ C 724 ◦ C failure data, prior experience, or from engineering knowledge
Opening furnace 725 ◦ C 50 ◦ C of the physics of the failure”. Given ˇ, an equation may be
Cooling rate – 10 ◦ C/min derived using the method of maximum likelihood to deter-
mine the characteristic life, , as follows [36,37]:

at room temperature. This thermal cycle followed manufac-   ˇ1


turer’s recommendation published in 2009 [27]. 
N
Tˇi
= (1)
• Slow cooling protocol: the furnace had the cooling rate set to r
i=1
10 ◦ C/min and crowns were kept into the furnace until the
temperature reached 50 ◦ C, after which the furnace head
where Ti , test time for each sample; r, number of failures; N,
was opened.
sample size; , characteristic life of the cumulative density
function (CDF) = 63.2%; ˇ, Weibull shape parameter.
The glazed crowns were cemented to the aged resin- A Weibull distribution is derived from  (determined by Eq.
composite tooth replicas using a dual cure resin cement (Rely (1)) using the assumed ˇ. The 2-parameter Weibull probability
X ARC – 3M-ESPE, St. Paul, MN, USA) following the manu- result was plotted using the counter group Weibayes value for
facturer’s instructions. No treatment was made in the Y-TZP pairwise comparisons. If two or more groups showed no fail-
cementation surface. Prior to mechanical testing, samples ures, the Weibayes lines were plotted and a probability Weibull
were incubated in distilled water at 37 ◦ C for at least 24 h. graphic generated.

2.2. Fatigue test


2.4. Failure mode characterization

Fatigue test was carried out in a fatigue machine (Model MSFM


The criteria for failure were inner cone cracks reaching
– Elquip – São Carlos, SP, Brazil) in r-ratio mode at a 30–300 N
the Y-TZP framework, porcelain veneer cohesive fracture
load range for 106 cycles or until failure under distilled water
or Y-TZP core fracture. Representative fractured surfaces
(37 ◦ C) [3]. As the indenter was in contact with the specimen,
were characterized under polarized-light microscopy (MZ-
the initial contact load of 30 N was applied without abrasion,
APO stereomicroscope, Carl Zeiss MicroImaging, Thornwood,
attrition or impact, steadily increasing to 300 N and decreasing
NY, USA) followed by Scanning Electron Microscopy (SEM)
back to 30 N. The load was applied through a spherical steel
(Model S-3500N; Hitachi, Japan). If no fractures were noted
indenter (3.18 mm radius) on the center of the occlusal sur-
after completion of final fatigue interval, the specimen was
face, at 2 Hz. Our attempt was to simulate the most typical
considered as suspended. Subsequently, to characterize the
molar relationship in natural dentition (Angle class I) where
subsurface damage, suspended crowns were embedded in
the mesiolingual cusp of the maxillary first molar is situated
epoxy resin (Resina Epoxi RD6921, Redelease, São Paulo,
in the central fossa area of the mandibular first molar [35].
Brazil), sectioned and then serially polished along the plane of
After a predetermined number of cycles (125,000) the test was
crack extension with silicon carbide papers (320, 400, 500, 600,
interrupted for crown surface damage accumulation inspec-
1200, 2000 and 2500 grits), under copious water irrigation. The
tion under stereomicroscopy (Leica Zeiss MZE, Mannheim,
damage accumulation was inspected and registered under
Germany). Specimens were then repositioned in the machine
stereomicroscopy (Leica Zeiss MZE, Mannheim, Germany).
for an additional 125,000 cycles and inspections until comple-
tion of 106 cycles or failure.
3. Results
2.3. Data analysis
During fatigue testing, all crowns fast cooled, from Zr-CFast
The failure during fatigue was recorded as a function of the and Zr-MFast groups, failed before completion of 1,000,000
number of cycles. This information was used to determine cycles chiefly by porcelain cohesive fracture. Three crowns
the interval databased 2-parameter probability Weibull dis- with conventional framework and five from the modified fast
tribution for Zr-CFast and Zr-MFast (Weibull 7++; Reliasoft, cooled groups did not present chippings. However, the sub-
Tucson, AZ, USA). Weibull shape parameter Beta (ˇ) and char- surface damage inspection of these crowns revealed inner
acteristic value Eta () (here the number of stress cycles (n) at cone cracks reaching the core/veneer interface. While inner
which 62.3% of the specimens would fail) were determined cone cracks reaching the interface reflect the porcelain’s fail-
employing 90% confidence levels for upper and lower lim- ure to resist crack growth, they do not represent a clinical
its where applicable. If either one of groups displayed no fracture per se, only the porcelain fractured crowns were con-
failures, a Weibayes [36] calculation was employed based on sidered for further analysis (n = 7 from the Zr-CFast and n = 5

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx 5

Fig. 3 – (a) Probability Weibull 2P plot showing probability line for Zr-CFast and Weibayes line projection of group Zr-CSlow.
Note that 90%CB calculation for Zr-CFast did not allow confidence intervals. (b) Probability Weibull 2P plot showing
probability line calculation of Zr-MFast and Weibayes probability line projection of group Zr-MSlow. (c) Probability Weibull
plot showing the Zr-CSlow and Zr-MSlow Weibayes projection lines. Note the different inclination of the probability lines as
a result of the different Beta values: ˇ = 4.38 for Zr-MSlow and ˇ = 5.53 for Zr-CSlow.

from the Zr-MFast). Conversely, crowns subjected to the slow are shown in Fig. 3. For the results distribution, the groups
cooling protocol, regardless of framework design, (Zr-CSlow were plotted based on the core design varying the cooling rate
and Zr-MSlow) were suspended since they did not fail at the process as described in materials and methods. 2-Parameter
completion of 106 cycles. Results of the Weibull calculation Weibull calculation was performed for Zr-CFast and Zr-MFast.

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
6 d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx

Fig. 4 – (a) Light-polarized microscope and SEM images of a representative failed Zr-MFast crown. Palatal view of cohesive
porcelain fracture shows that the crack involved the lingual cusp. (b) SEM lingual view displaying the indentation area
(asterisk) and the dotted arrows shows the crack propagation toward the cervical and proximal areas. (c) and (d) The
concave portion of the arrest lines (pointer) points to the origin (asterisk). Continued propagation toward the margins is
suggested by the series of hackles (bowshot). (e) and (f) Magnification of wake-hackles (pointers) corroborating the origin
and direction of crack propagation along with twist-hackles (white arrows).

Groups Zr-CSlow and Zr-MSlow did not present any failure, the confidence bounds. Fig. 3 also presents the Weibayes prob-
and therefore Weibayes calculation was performed [36]. In our ability line calculations for groups Zr-MSlow and Zr-CSlow.
study we used the ˇ value from the respective counter group’s
design and ran Weibayes calculation. 2-parameter Weibull 3.1. Failure modes
calculation presented ˇ = 5.53 and ˇ = 4.38 for Zr-MFast and Zr-
CFast respectively. The Weibayes calculation using the same The chief failure mode observed for crowns subjected to the
ˇ values for the respective counter presented a shift to the fast cooling protocol was porcelain veneer cohesive fracture,
right of the Weibull probability lines (longer fatigue life). The 2- regardless of framework design (Zr-CFast, Zr-MFast), with-
parameter Weibull calculation for group Zr-CFast did not allow out exposing the Y-TZP surface. Of special interest was the
90% confidence intervals calculation as a result of the distri- fact that smaller chippings were consistently observed for
bution of the failed specimens. However there is a significant Zr-MFast relative to Zr-CFast group. In the Zr-MFast group,
shift to the right of the Weibayes probability line for its counter chippings were generally confined to the lingual cusp (Fig. 4),
part group. Groups Zr-MFast and Zr-MSlow presented no sta- whereas chip-off fractures extending to the proximal sur-
tistical difference as a result of overlap of the upper limit of faces were observed in Zr-CFast crows (Fig. 5). Qualitative

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx 7

Fig. 5 – (a) Light-polarized microscope image of a Zr-CFast crown shows the extension of the fractured porcelain veneer.
Note that a layer of porcelain remained onto the Y-TZPs framework surface. (b) SEM lingual overview of the fractured crown
and indentation area (asterisk) where the fracture initiated and propagated toward margins and proximal areas (dotted
arrows). (c) Magnification of (b) showing the presence of a series of wake-hackles (pointers) confirming the fracture origin
and direction of the crack propagation (dotted arrow). (d) A series of twist-hackles (white arrows) that strongly suggests the
presence of residual thermal stress and further confirms the direction of crack propagation toward the margin of the fracture.

fractography performed in polarized-light microscopy and life within either the fast or slow cooled crowns. However
SEM showed the presence of quasiplastic deformation at the when intergroup comparisons were made, the relevance of a
indentation area. Telltale fractographic marks including hack- modified framework should not be overlooked since the Zr-
les, wake hackles, and arrest lines suggesting the direction of MFast crowns were not statistically different from slow cooled
crack propagation from the indentation area toward the mar- crowns of any framework design. Nevertheless, it appears that
gins of the fractured porcelain veneer were observed. Twist cooling protocols played a major role in fatigue life in the
hackles were only identified in those groups subjected to fast current study. As expected from previous studies [6,9,38], no
cooling. Y-TZP core fractures were detected. When porcelain veneer
Crowns subjected to the slow cooling protocol of both fractures occurred, they were always cohesive within the
framework designs (Zr-CSlow and Zr-MSlow) were consid- porcelain veneer, without exposing the Y-TZP core [3,5,39–42].
ered suspended since they did not present failures at the Crowns cooled slowly did not present porcelain chippings
completion of the 106 cycles. The subsurface damage inspec- within the established limit of one million fatigue cycles and
tion of these specimens revealed inner cone cracks as the the only observed failure mode was near-field damage (inner
dominant crack system mechanism in all samples from both cone crack), in both framework designs. It is likely that such
groups, although they did not reach the core/porcelain inter- fatigue performance improvement may be explained by a
face (Fig. 6). No radial crack and bulk fractures were observed. reduction in residual stress entrapment within the veneer
layer [16,20,23]. A recent investigation evaluated the influ-
ence of cooling protocols on thermal stress formation in Y-TZP
4. Discussion molar crowns showing that when samples were cooled slowly
the outer porcelain veneer surface did not become solid first
The present study evaluated the effect of cooling processes (due to the absence of thermal gradient) allowing residual
and framework designs on Y-TZP molar crowns fatigue thermal stress relaxation by viscosity flow [23]. As fatigue
life. The absence of statistical difference in fatigue life in testing was suspended at one million cycles to allow for dam-
crowns submitted to the slow cooling protocol, regardless age inspection of groups within the same range of cycles,
of framework design, lead us to reject the first postulated it must be acknowledged that extended fatigue could have
null hypothesis. The second null hypothesis was accepted provided a more clinically realistic failure scenario, although
since framework design modification did not improve fatigue increasing testing time to an unknown extent. In addition, as

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
8 d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx

Fig. 6 – (a) Occlusal light-polarized micrograph shows the indenter contact area on the porcelain surface and the resulting
quasiplastic deformation on a Zr-MSlow crown. (b) Magnification of the square area showed in (a), reveals the presence of
quasiplatic deformation, which is a coalescing microcrak involving the indentation area (bowshot) after 106 cycles. (c)
Bucco-lingual section of the same crown, polished and examined throughout the damaged area, showing inner cone crack
formation immediately below the indentation area, not reaching the zirconia/veneer interface (d) Magnification of the inner
cone crack confirming its extension. (e) Bucco-lingual section micrograph of a polished Zr-CSlow crown showing the
indentation area in the blue square and in (f) its magnification revealing inner cone cracks (pointer) formed immediately
bellow the indentation area, also not reaching the interface. R = resin composite; Y-TZP = zirconia framework; V = veneering
porcelain.

sliding-fatigue was omitted, porcelain fractures revealed ori- reduce thermal gradients [12,23,46]. A comprehensive eval-
gin from the occlusal surface, but not related to surface uation of stress distribution within the veneering ceramic
roughness due to wear, as reported in clinical fractogra- as a function of depth toward the substructure material has
phy [43] and laboratory studies involving such methodology shown that zirconia veneered samples present tensile stresses
[2,44,45,47]. around 0.5 mm from the surface with magnitude varying
Regarding the slow cooling protocol used in this study, inversely to the cooling rate [26].
it must be emphasized that it is experimental for having Y-TZP crowns cooled fast resulted in similar fatigue life,
extended the slow cooling process below the Tg , in contrast to irrespective of framework design, but remarkable differences
what is currently recommended by most manufacturers (slow were observed in porcelain cohesive fracture sizes. Whereas
cooling in the last stain/glaze firing cycle until Tg ). Whereas fractures in the modified Y-TZP framework were confined to
the maintenance of the crowns into the furnace until 50 ◦ C lingual cusp, those in the conventional designed were more
demanded additional laboratory time, it may be important to extensive often involving both approximals in addition to the

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx 9

buccal cusp. Despite such differences, from a clinical stand- a cohesive fracture from the extension of the inner cone crack-
point only crowns with modified framework would potentially ing [49–52]. Suspended crowns subjected to the slow cooling
be repaired, although ideally both would require replacement. protocol showed cone cracks formation virtually confined to
Such an observation questions the suitability of this partic- the quasiplastic zone beneath the indenter and therefore not
ular framework design modification since it results in an reaching the Y-TZP framework and are much less likely to lead
even porcelain thickness only on the lingual side. Perhaps, an to cohesive failure with continued loading.
anatomic core design that provides an even thickness in all As observed in clinical trials, the proximal region has been
cusps and proximal areas could be more relevant as recom- regarded as an area specially affected by chipping [6,14,30,53].
mended by several manufacturers. A recent study shows that In a natural occlusal scheme the mesio bucal cusp of the first
an anatomical support of the veneering ceramic resulted in mandibular molar may contact the marginal ridges of both
reduced veneer chip size fractures and significantly increased second premolar and first maxillary molar [54,55]. This sug-
reliability with press and hand-layer veneering ceramics and gests that future fatigue testing in the proximal areas may be
appears to be a promising tool to optimize long-term perfor- of clinical relevance.
mance of veneered Y-TZP crowns in clinical application [29].
One important fractographic finding was the consistent
presence of twist hackles in the groups cooled by the fast 5. Conclusions
protocol. Although it was not our aim to perform residual
thermal stress measurements, the presence of twist hackles, The first postulated null hypothesis which stated that cool-
strongly suggest the presence of significant thermal stress gra- ing protocols during glazing would not improve the fatigue
dients [47], which were induced in our study by the fast cooling life of Y-TZP crowns was partially rejected. Decreased fatigue
protocol [16,23,46]. life was observed only for crowns fast cooled of conventional
Our Weibayes use of an assumed beta value means that framework compared to any slow cooled crowns, whereas
always there is a “risk” of using a beta higher than the “true” modified framework fast cooled crowns were not signifi-
value [37]. In this context, the impact of a higher beta is being cantly different from slow cooled ones. The second null
overly optimistic in the interpretation of the demonstrate reli- hypothesis was accepted since framework design modifica-
ability and the possible exclusion of early failures. In our tion did not improve fatigue life within either the fast or
study the beta value employed is based upon the ˇ value from slow cooled crowns. Slow cooling protocol is recommended for
the respective counter group (fast cooled), which displayed a more predictable mechanical performance of layered-zirconia
higher number of failures than the slow cooled groups. More- restorations.
over, a way to investigate the effect of changes in an assumed
beta is by assuming two beta values (two beta lines), where
Acknowledgements
the higher the cumulative density function (CDF) level of the
beta line intersection point, the greater the risk of reaching
We thank Dr. Raphael Piazzarollo Loureiro for his input on
an overly optimistic conclusion for a fixed By life below that
ceramic processing engineering and the dental technician José
intersection point [37].
Carlos Romanini for crown fabrication. This study was sup-
Also, if two beta values were assumed, one as calculated
ported, in part, by CNPq, and FAPESP Grant 2010/06152-9. The
from results of the counter group and the other reduced by
authors acknowledge Hitachi S3500N SEM imaging that was
two units, one graphic including both beta lines would be
made possible by the New York University College of Den-
generated. For a given N = 10 (based on our sample size), the
tistry’s cooperative agreement with the NIH/NIDCR.
intersection of two beta lines is known as beta intersection
point and it most likely occurs at approximately CDF of 10%
(here the test time on each of the “N” samples is equal). For a references
larger “N”, the beta intersection point occurs at less than 10%.
Such assumption is based on a general rule for beta intersec-
tion point where the smaller the Weibayes test sample size, [1] Bonfante EA, Rafferty B, Zavanelli RA, Silva NR, Rekow ED,
the higher the CDF value at which the beta intersection point Thompson VP, et al. Thermal/mechanical simulation and
occurs [37]. Thus, our limited number of samples would allow laboratory fatigue testing of an alternative yttria tetragonal
a lower beta intersection point close to the B10 life where 10% zirconia polycrystal core-veneer all-ceramic layered crown
design. Eur J Oral Sci 2010;118:202–9.
of samples would fail.
[2] Coelho PG, Silva NR, Bonfante EA, Guess PC, Rekow ED,
It is acknowledged that several damage modes can com- Thompson VP. Fatigue testing of two porcelain-zirconia
pete during the fatigue test such as radial cracks (far-field all-ceramic crown systems. Dent Mater 2009;25:1122–7.
damage) and inner, outer, and partial cone cracks (near-field [3] Lorenzoni FC, Martins LM, Silva NR, Coelho PG, Guess PC,
damage) [48–50]. The failure characterization by polishing Bonfante EA, et al. Fatigue life and failure modes of crowns
showed that some of the suspended samples (three ZR-CFast systems with a modified framework design. J Dent
2010;38:626–34.
and four Zr-MFast) presented inner cone cracks reaching the
[4] Silva NR, Bonfante EA, Rafferty BT, Zavanelli RA, Rekow ED,
core/veneer interface. Because from a clinical perspective the
Thompson VP, et al. Modified Y-TZP core design improves
absence of external porcelain fracture, as in the presence of all-ceramic crown reliability. J Dent Res 2011;90:104–8.
inner cone cracks reaching the interface, leads to a diagnosis [5] Silva NR, Bonfante EA, Zavanelli RA, Thompson VP, Ferencz
of crown survival, they were not deemed as failures for data JL, Coelho PG. Reliability of metalloceramic and
analysis. With continued load cycling it would likely evolve to zirconia-based ceramic crowns. J Dent Res 2010;89:1051–6.

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
10 d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx

[6] Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a DATA%5Cclient%5Civoclar%5Cmedia%5Cdownloads%5C/


systematic review. J Oral Rehabil 2010;37:641–52. Media 611442002pdf/true/application%5Cpdf/EP3000
[7] Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. progtab cf enpdf
Five-year clinical results of zirconia frameworks for posterior [28] Ivoclar. Programat® EP 3000 – program table; 2010
fixed partial dentures. Int J Prosthodont 2007;20:383–8. http://wwwivoclarvivadentcom/zoolu-website/media/
[8] Zarone F, Russo S, Sorrentino R. From document/4611/Programat+-+Firing+program+tables
porcelain-fused-to-metal to zirconia: clinical and [29] Guess PC, Bonfante EA, Silva NR, Coelho PG, Thompson VP.
experimental considerations. Dent Mater 2011;27:83–96. Effect of core design and veneering technique on damage
[9] Guazzato M, Walton TR, Franklin W, Davis G, Bohl C, and reliability of Y-TZP-supported crowns. Dent Mater
Klineberg I. Influence of thickness and cooling rate on 2013;29:307–16.
development of spontaneous cracks in porcelain/zirconia [30] Scherrer SS, Quinn JB, Quinn GD, Wiskott HW. Fractographic
structures. Aust Dent J 2010;55:306–10. ceramic failure analysis using the replica technique. Dent
[10] Rues S, Kroger E, Muller D, Schmitter M. Effect of firing Mater 2007;23:1397–404.
protocols on cohesive failure of all-ceramic crowns. J Dent [31] McLean JW. Preparation an the design of metal
2010;38:987–94. substructures. In: Quintessence, editor. Dental ceramics.
[11] Asaoka K, Tesk JA. Transient and residual stress in a Hanover Park: Quintessence; 1983.
porcelain-metal strip. J Dent Res 1990;69:463–9. [32] Molin MK, Karlsson SL. Five-year clinical prospective
[12] Swain MV. Unstable cracking (chipping) of veneering evaluation of zirconia-based Denzir 3-unit FPDs. Int J
porcelain on all-ceramic dental crowns and fixed partial Prosthodont 2008;21:223–7.
dentures. Acta Biomater 2009;5:1668–77. [33] Schmitter M, Mussotter K, Rammelsberg P, Stober T,
[13] Bonfante EA, da Silva NR, Coelho PG, Bayardo-Gonzalez DE, Ohlmann B, Gabbert O. Clinical performance of extended
Thompson VP, Bonfante G. Effect of framework design on zirconia frameworks for fixed dental prostheses: two-year
crown failure. Eur J Oral Sci 2009;117:194–9. results. J Oral Rehabil 2009;36:610–5.
[14] Marchack BW, Futatsuki Y, Marchack CB, White SN. [34] Huang M, Thompson VP, Rekow ED, Soboyejo WO. Modeling
Customization of milled zirconia copings for all-ceramic of water absorption induced cracks in resin-based
crowns: a clinical report. J Prosthet Dent 2008;99:169–73. composite supported ceramic layer structures. J Biomed
[15] Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Mater Res B: Appl Biomater 2008;84:124–30.
Spiekermann H. Clinical behavior of zirconia-based fixed [35] Okeson J. Alignment and occlusion of the dentition.
partial dentures made of DC-Zirkon: 3-year results. Int J Management of temporomandibular disorders and
Prosthodont 2008;21:217–22. occlusion. 7th ed. Mosby; 2012. p. 58–80.
[16] Choi JE, Waddell JN, Swain MV. Pressed ceramics onto [36] Abernethy RB. In: Abernethy RB, editor. The new Weibull
zirconia, Part 2: Indentation fracture and influence of handbook fifth edition, reliability and statistical analysis for
cooling rate on residual stresses. Dent Mater 2011;27:1111–8. predicting life, safety, supportability, risk, cost and warranty
[17] Gostemeyer G, Jendras M, Dittmer MP, Bach FW, Stiesch M, claims. fifth ed. 2007.
Kohorst P. Influence of cooling rate on zirconia/veneer [37] Nicholls D, Lein P. Weibayes testing: what is the impact if
interfacial adhesion. Acta Biomater 2010;6:4532–8. assumed beta is incorrect? Reliability and maintainability
[18] Fischer J, Stawarczyk B, Tomic M, Strub JR, Hammerle CH. symposium, 2009 RAMS 2009 Annual 2009. 2009. p. 37–42.
Effect of thermal misfit between different veneering [38] Denry I, Kelly JR. State of the art of zirconia for dental
ceramics and zirconia frameworks on in vitro fracture load applications. Dent Mater 2008;24:299–307.
of single crowns. Dent Mater J 2007;26:766–72. [39] Guess PC, Zhang Y, Thompson VP. Effect of veneering
[19] Fairhurst CW, Hashinger DT, Twiggs SW. Glass transition techniques on damage and reliability of Y-TZP trilayers. Eur J
temperatures of dental porcelain. J Dent Res 1981;60:995–8. Esthet Dent 2009;4:262–76.
[20] Baldassarri M, Stappert CF, Wolff MS, Thompson VP, Zhang [40] Rekow D, Zhang Y, Thompson V. Can material properties
Y. Residual stresses in porcelain-veneered zirconia predict survival of all-ceramic posterior crowns? Compend
prostheses. Dent Mater 2012;28:873–9. Contin Educ Dent 2007;28:362–8, quiz 69, 86.
[21] O’Brien WJ. Dental materials and their selection. Hanover [41] Tholey MJ, Berthold C, Swain MV, Thiel N. XRD2
Park, IL: Quintessence Publishing Co, Inc.; 2008. micro-diffraction analysis of the interface between Y-TZP
[22] Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, and veneering porcelain: role of application methods. Dent
fracture toughness and microstructure of a selection of Mater 2010;26:545–52.
all-ceramic materials, Part II. Zirconia-based dental [42] Tholey MJ, Swain MV, Thiel N. SEM observations of porcelain
ceramics. Dent Mater 2004;20:449–56. Y-TZP interface. Dent Mater 2009;25:857–62.
[23] Tholey MJ, Swain MV, Thiel N. Thermal gradients and [43] Koenig V, Vanheusden AJ, Le Goff SO, Mainjot AK. Clinical
residual stresses in veneered Y-TZP frameworks. Dent Mater risk factors related to failures with zirconia-based
2011;27:1102–10. restorations: an up to 9-year retrospective study. J Dent
[24] Komine F, Saito A, Kobayashi K, Koizuka M, Koizumi H, 2013;41:1164–74.
Matsumura H. Effect of cooling rate on shear bond strength [44] Belli R, Frankenberger R, Appelt A, Schmitt J, Baratieri LN,
of veneering porcelain to a zirconia ceramic material. J Oral Greil P, et al. Thermal-induced residual stresses affect the
Sci 2010;52:647–52. lifetime of zirconia-veneer crowns. Dent Mater
[25] Tan JP, Sederstrom D, Polansky JR, McLaren EA, White SN. 2013;29:181–90.
The use of slow heating and slow cooling regimens to [45] Coelho PG, Bonfante EA, Silva NR, Rekow ED, Thompson VP.
strengthen porcelain fused to zirconia. J Prosthet Dent Laboratory simulation of Y-TZP all-ceramic crown clinical
2012;107:163–9. failures. J Dent Res 2009;88:382–6.
[26] Mainjot AK, Schajer GS, Vanheusden AJ, Sadoun MJ. [46] Mainjot AK, Schajer GS, Vanheusden AJ, Sadoun MJ. Residual
Influence of cooling rate on residual stress profile in stress measurement in veneering ceramic by hole-drilling.
veneering ceramic: measurement by hole-drilling. Dent Dent Mater 2011;27:439–44.
Mater 2011;27:906–14. [47] Quinn GD. Fractography of ceramics and glasses.
[27] Ivoclar. Programat® EP 3000 – program table; 2009 http:// Washington, DC: National Institute of Standards and
icubusivoclarvivadentcom/Secure30/media area/ivoclar/C/ Technology; 2007.

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005
DENTAL-2455; No. of Pages 11
ARTICLE IN PRESS
d e n t a l m a t e r i a l s x x x ( 2 0 1 4 ) xxx–xxx 11

[48] Kim JH, Kim JW, Myoung SW, Pines M, Zhang Y. Damage [52] Bhowmick S, Melendez-Martinez JJ, Hermann I, Zhang Y,
maps for layered ceramics under simulated mastication. J Lawn BR. Role of indenter material and size in veneer failure
Dent Res 2008;87:671–5. of brittle layer structures. J Biomed Mater Res B: Appl
[49] Rekow D, Thompson V. Near-surface damage-a persistent Biomater 2007;82:253–9.
problem in crowns obtained by computer-aided design and [53] Zhang Y, Chai H, Lee JJ, Lawn BR. Chipping resistance of
manufacturing. Proc Inst Mech Eng H: J Eng Med graded zirconia ceramics for dental crowns. J Dent Res
2005;219:233–43. 2012;91:311–5.
[50] Rekow D, Thompson VP. Engineering long term clinical [54] Wiskott HW, Belser UC. A rationale for a simplified occlusal
success of advanced ceramic prostheses. J Mater Sci Mater design in restorative dentistry: historical review and clinical
Med 2007;18:47–56. guidelines. J Prosthet Dent 1995;73:169–83.
[51] Wiskott HW, Nicholls JI, Belser UC. Stress fatigue: basic [55] Myers GE, Anderson Jr JR. Nature of contacts in centric
principles and prosthodontic implications. Int J Prosthodont occlusion in 32 adults. J Dent Res 1971;50:7–13.
1995;8:105–16.

Please cite this article in press as: Paula VG, et al. Slow cooling protocol improves fatigue life of zirconia crowns. Dent Mater (2014),
http://dx.doi.org/10.1016/j.dental.2014.10.005