Sunteți pe pagina 1din 34

ANNEX A

Solar calculator
A.1- Seville, Spain
(Maroua ganna)
Partner Report - Solar calculator
Project Overview

Project name Thermal system


Number of people 4
Annual electricity internal consumption 3300 kWh
Tilt angle 33°
Orientation

(E = +90°, S = 0°, W = -90°)

Photograph of property Map section

This report has been created by: Location of the system


SONNENKRAFT online calculator sevilla
Longitude: -5.99°
Latitude: 37.383°
Elevation: 8 m

Schematic view of system Symbolic view of system

The exact dimensioning of the individual components in the solar system must be project specific and in accordance with the regional
requirements.
The exact dimensioning of the inverter must be project-specific and in accordance with the requirements of the regional utility company

1 / 7 V10.1.5.25637 / 13.12.2018 / 17:38:53


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Overview solar thermal energy (annual values)

Collector area 5.1 m²


Solar fraction total 94.1%
Total annual field yield 3,182.9 kWh
Collector field yield relating to gross area 619.2 kWh/m²/Year
Collector field yield relating to aperture area 694.9 kWh/m²/Year
Max. energy savings 4,300.4 kWh
Max. reduction in CO2 emissions 547 kg

System overview (annual values)

Total fuel and/or electricity consumption of the


1,307 kWh
system [Etot]
Total energy consumption [Quse] 1,670 kWh
Comfort demand Energy demand covered

Overview photovoltaics (annual values)

Total gross area 13.2 m²


Energy production DC [Qpvf] 3,442.1 kWh
Energy production AC [Qinv] 3,280.2 kWh
Total nominal power generator field 2.08 kW
Performance ratio 78.7 %
Specific annual yield 1,577 kWh
CO2 savings 1,760 kg

2 / 7 V10.1.5.25637 / 13.12.2018 / 17:38:53


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator
Solar fraction: fraction of solar energy
to system [SFn] % Horizon line

Meteorological data-Overview

Average outdoor temperature 19.7 °C


Global irradiation, annual sum 1,756 kWh/m²
Diffuse irradiation, annual sum 628 kWh/m²

Component overview (annual values)

Heat pump 1 Heat pump 15 kW


Heating power at A2/W35 kW 13.6
Electrical power at A2/W35 kW 3.9
COP at A2/W35 3.5
DeltaT at A7/W35 K 9.9
Energy from/to the system [Qaux] kWh 201
Fuel and electricity consumption [Eaux] kWh 64.5
Energy savings solar thermal kWh 1,020
CO2 savings solar thermal kg 547
Energy savings heat pump kWh 137
CO2 savings heat pump kg 73.4

Hot water demand Daily peaks


Volume withdrawal/daily consumption l/d 153
Temperature setting °C 45
Energy demand [Qdem] kWh 1,653

3 / 7 V10.1.5.25637 / 13.12.2018 / 17:38:53


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Collector SK500N-ECO-AL
Number of collectors 2
Number of arrays 1
Total gross area m² 5.14
Total aperture area m² 4.58
Tilt angle (hor.=0°, vert.=90°) ° 33
Orientation (E=+90°, S=0°, W=-90°) ° 0
Collector field yield [Qsol] kWh 3,183

Photovoltaics Roof plan 1 KPV 260 PE NEC


Manufacturer Kioto Photovoltaics
Data Source Photovoltaikforum
Number of modules 8
Total nominal power generator field kW 2.08
Total gross area m² 13.2
Tilt angle (hor.=0°, vert.=90°) ° 33
Orientation (E=+90°, S=0°, W=-90°) ° 0
Layout 1: Number of inverters 1
Layout 1: A number of strings 1
Layout 1: A modules per string 8
Energy production DC [Qpvf] kWh 3,442
Energy production AC [Qinv] kWh 3,280
Specific annual yield kWh 1,577

Storage tank
DHW400
with RLGHE
Volume l 400

4 / 7 V10.1.5.25637 / 13.12.2018 / 17:38:53


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Solar thermal energy to the system [Qsol] kWh

Solar fraction: fraction of solar energy to system [SFn] %

5 / 7 V10.1.5.25637 / 13.12.2018 / 17:38:53


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Total fuel and/or electricity consumption of the system [Etot] kWh

Yield Photovoltaics AC [Qinv] kWh

6 / 7 V10.1.5.25637 / 13.12.2018 / 17:38:53


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Collector Daily maximum temperature [ °C]

Energy flow diagram (annual balance)

7 / 7 V10.1.5.25637 / 13.12.2018 / 17:38:53


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
A.2- Bari, Italy
(Cyril Lemercier)
Partner Report - Solar calculator
Project Overview

Project name
Number of people 4
Annual electricity internal consumption 3300 kWh
Tilt angle 34°
Orientation

(E = +90°, S = 0°, W = -90°)

Photograph of property Map section

This report has been created by: Location of the system


SONNENKRAFT online calculator
Longitude: 16.863°
Latitude: 41.103°
Elevation: 23 m

Schematic view of system Symbolic view of system

The exact dimensioning of the individual components in the solar system must be project specific and in accordance with the regional
requirements.
The exact dimensioning of the inverter must be project-specific and in accordance with the requirements of the regional utility company

1 / 7 V10.1.5.25637 / 13.12.2018 / 17:31:46


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Overview solar thermal energy (annual values)

Collector area 5.2 m²


Solar fraction total 85.5%
Total annual field yield 3,072.8 kWh
Collector field yield relating to gross area 595.5 kWh/m²/Year
Collector field yield relating to aperture area 679.8 kWh/m²/Year
Max. energy savings 4,001.3 kWh
Max. reduction in CO2 emissions 558 kg

System overview (annual values)

Total fuel and/or electricity consumption of the


1,737 kWh
system [Etot]
Total energy consumption [Quse] 1,908 kWh
Comfort demand Energy demand covered

Overview photovoltaics (annual values)

Total gross area 13.2 m²


Energy production DC [Qpvf] 3,112.1 kWh
Energy production AC [Qinv] 2,961.2 kWh
Total nominal power generator field 2.08 kW
Performance ratio 79.8 %
Specific annual yield 1,424 kWh
CO2 savings 1,588 kg

2 / 7 V10.1.5.25637 / 13.12.2018 / 17:31:46


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator
Solar fraction: fraction of solar energy
to system [SFn] % Horizon line

Meteorological data-Overview

Average outdoor temperature 16 °C


Global irradiation, annual sum 1,563 kWh/m²
Diffuse irradiation, annual sum 618 kWh/m²

Component overview (annual values)

Heat pump 1 Heat pump 15 kW


Heating power at A2/W35 kW 13.6
Electrical power at A2/W35 kW 3.9
COP at A2/W35 3.5
DeltaT at A7/W35 K 9.9
Energy from/to the system [Qaux] kWh 521
Fuel and electricity consumption [Eaux] kWh 176
Energy savings solar thermal kWh 1,040
CO2 savings solar thermal kg 558
Energy savings heat pump kWh 345
CO2 savings heat pump kg 185

Hot water demand Daily peaks


Volume withdrawal/daily consumption l/d 153
Temperature setting °C 45
Energy demand [Qdem] kWh 1,893

3 / 7 V10.1.5.25637 / 13.12.2018 / 17:31:46


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Collector SKR500
Number of collectors 2
Number of arrays 1
Total gross area m² 5.16
Total aperture area m² 4.52
Tilt angle (hor.=0°, vert.=90°) ° 34
Orientation (E=+90°, S=0°, W=-90°) ° 0
Collector field yield [Qsol] kWh 3,073

Photovoltaics Roof plan 1 KPV 260 PE NEC


Manufacturer Kioto Photovoltaics
Data Source Photovoltaikforum
Number of modules 8
Total nominal power generator field kW 2.08
Total gross area m² 13.2
Tilt angle (hor.=0°, vert.=90°) ° 34
Orientation (E=+90°, S=0°, W=-90°) ° 0
Layout 1: Number of inverters 1
Layout 1: A number of strings 1
Layout 1: A modules per string 8
Energy production DC [Qpvf] kWh 3,112
Energy production AC [Qinv] kWh 2,961
Specific annual yield kWh 1,424

Storage tank
DHW400
with RLGHE
Volume l 400

4 / 7 V10.1.5.25637 / 13.12.2018 / 17:31:46


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Solar thermal energy to the system [Qsol] kWh

Solar fraction: fraction of solar energy to system [SFn] %

5 / 7 V10.1.5.25637 / 13.12.2018 / 17:31:46


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Total fuel and/or electricity consumption of the system [Etot] kWh

Yield Photovoltaics AC [Qinv] kWh

6 / 7 V10.1.5.25637 / 13.12.2018 / 17:31:46


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Collector Daily maximum temperature [ °C]

Energy flow diagram (annual balance)

7 / 7 V10.1.5.25637 / 13.12.2018 / 17:31:46


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
A.3- Paris, France
(David Schroffner)
Partner Report - Solar calculator
Project Overview

Project name Exercise 3


Number of people 4
Building type Niedrigstenergiehaus (HWB ca. 30 kWh/m²a)
Annual electricity internal consumption 3300 kWh
Tilt angle 45°
Orientation

(E = +90°, S = 0°, W = -90°)
Heated building area 160 m²

Photograph of property Map section

This report has been created by: Location of the system


SONNENKRAFT online calculator
Longitude: 2.352°
Latitude: 48.852°
Elevation: 35 m

1 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator
Schematic view of system Symbolic view of system

The exact dimensioning of the individual components in the solar system must be project specific and in accordance with the regional
requirements.
The exact dimensioning of the inverter must be project-specific and in accordance with the requirements of the regional utility company

Overview solar thermal energy (annual values)

Collector area 15.5 m²


Solar fraction total 50.8%
Solar fraction hot water [SFnHw] 62.5 %
Solar fraction building [SFnBd] 29.3 %
Total annual field yield 4,237.3 kWh
Collector field yield relating to gross area 273.7 kWh/m²/Year
Collector field yield relating to aperture area 312.5 kWh/m²/Year
Max. energy savings 3,352.7 kWh
Max. reduction in CO2 emissions 778 kg

System overview (annual values)

Total fuel and/or electricity consumption of the


4,021 kWh
system [Etot]
Total energy consumption [Quse] 5,855 kWh
Comfort demand Energy demand covered

2 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Overview photovoltaics (annual values)

Total gross area 13.2 m²


Energy production DC [Qpvf] 2,017.1 kWh
Energy production AC [Qinv] 1,903.1 kWh
Total nominal power generator field 2.08 kW
Performance ratio 80 %
Specific annual yield 915 kWh
CO2 savings 1,021 kg

Solar fraction: fraction of solar energy


to system [SFn] % Horizon line

Meteorological data-Overview

Average outdoor temperature 12.2 °C


Global irradiation, annual sum 1,018 kWh/m²
Diffuse irradiation, annual sum 568 kWh/m²

Component overview (annual values)

3 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Heat pump HP12 M


Heating power at A2/W35 kW 10
Electrical power at A2/W35 kW 2.44
COP at A2/W35 4.1
DeltaT at A7/W35 K 5
Energy from/to the system [Qaux] kWh 4,111
Fuel and electricity consumption [Eaux] kWh 1,406
Energy savings solar thermal kWh 1,450
CO2 savings solar thermal kg 778
Energy savings heat pump kWh 2,705
CO2 savings heat pump kg 1,451

Hot water demand Daily peaks


Volume withdrawal/daily consumption l/d 153
Temperature setting °C 45
Energy demand [Qdem] kWh 2,147

Building -
Heated/air-conditioned living area m² 160
Heating setpoint temperature °C 21
Heating energy demand excluding DHW [Qdem] kWh 3,600
Annual specific heating energy demand kWh/m²/a 22.5
Useful heat gain kWh 7,200
Total energy losses kWh 10,800

Collector SKR500
Number of collectors 6
Number of arrays 2
Total gross area m² 15.48
Total aperture area m² 13.56
Tilt angle (hor.=0°, vert.=90°) ° 45
Orientation (E=+90°, S=0°, W=-90°) ° 0
Collector field yield [Qsol] kWh 4,237

4 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Photovoltaics Roof plan 1 KPV 260 PE NEC


Manufacturer Kioto Photovoltaics
Data Source Photovoltaikforum
Number of modules 8
Total nominal power generator field kW 2.08
Total gross area m² 13.2
Tilt angle (hor.=0°, vert.=90°) ° 45
Orientation (E=+90°, S=0°, W=-90°) ° 0
Layout 1: Number of inverters 1
Layout 1: A number of strings 1
Layout 1: A modules per string 8
Energy production DC [Qpvf] kWh 2,017
Energy production AC [Qinv] kWh 1,903
Specific annual yield kWh 915

Storage tank
with SLM50HE-O PSC 1000E (HP)
with FWM30i
Volume l 1,000

Heating/Cooling element Radiator


Nominal inlet temperature °C 45
Nominal return temperature °C 35
Net energy from/to heating/cooling modules kWh 3,524

5 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Solar thermal energy to the system [Qsol] kWh

Solar fraction: fraction of solar energy to system [SFn] %

6 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Total fuel and/or electricity consumption of the system [Etot] kWh

Yield Photovoltaics AC [Qinv] kWh

7 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Collector Daily maximum temperature [ °C]

Energy flow diagram (annual balance)

8 / 8 V10.1.5.25637 / 14.12.2018 / 19:33:03


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
A.4- Munich, Germany
(Adrián Cuberos)
Partner Report - Solar calculator
Project Overview

Project name Solar thermal System, Munich


Number of people 4
Annual electricity internal consumption 3300 kWh
Tilt angle 36°
Orientation

(E = +90°, S = 0°, W = -90°)

Photograph of property Map section

This report has been created by: Location of the system


SONNENKRAFT online calculator munich
Longitude: 11.582°
Latitude: 48.135°
Elevation: 515 m

Schematic view of system Symbolic view of system

The exact dimensioning of the individual components in the solar system must be project specific and in accordance with the regional
requirements.
The exact dimensioning of the inverter must be project-specific and in accordance with the requirements of the regional utility company

1 / 7 V10.1.5.25637 / 14.12.2018 / 19:20:13


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Overview solar thermal energy (annual values)

Collector area 7.7 m²


Solar fraction total 73.4%
Total annual field yield 2,968.1 kWh
Collector field yield relating to gross area 383.5 kWh/m²/Year
Collector field yield relating to aperture area 437.8 kWh/m²/Year
Max. energy savings 3,400.4 kWh
Max. reduction in CO2 emissions 599 kg

System overview (annual values)

Total fuel and/or electricity consumption of the


2,636 kWh
system [Etot]
Total energy consumption [Quse] 2,356 kWh
Comfort demand Energy demand covered

Overview photovoltaics (annual values)

Total gross area 13.2 m²


Energy production DC [Qpvf] 2,411.6 kWh
Energy production AC [Qinv] 2,283.9 kWh
Total nominal power generator field 2.08 kW
Performance ratio 81.4 %
Specific annual yield 1,098 kWh
CO2 savings 1,225 kg

2 / 7 V10.1.5.25637 / 14.12.2018 / 19:20:13


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator
Solar fraction: fraction of solar energy
to system [SFn] % Horizon line

Meteorological data-Overview

Average outdoor temperature 9 °C


Global irradiation, annual sum 1,151 kWh/m²
Diffuse irradiation, annual sum 571 kWh/m²

Component overview (annual values)

Heat pump 1 Heat pump 15 kW


Heating power at A2/W35 kW 13.6
Electrical power at A2/W35 kW 3.9
COP at A2/W35 3.5
DeltaT at A7/W35 K 9.9
Energy from/to the system [Qaux] kWh 1,078
Fuel and electricity consumption [Eaux] kWh 406
Energy savings solar thermal kWh 1,117
CO2 savings solar thermal kg 599
Energy savings heat pump kWh 672
CO2 savings heat pump kg 361

Hot water demand Daily peaks


Volume withdrawal/daily consumption l/d 153
Temperature setting °C 45
Energy demand [Qdem] kWh 2,353

3 / 7 V10.1.5.25637 / 14.12.2018 / 19:20:13


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Collector SKR500
Number of collectors 3
Number of arrays 1
Total gross area m² 7.74
Total aperture area m² 6.78
Tilt angle (hor.=0°, vert.=90°) ° 36
Orientation (E=+90°, S=0°, W=-90°) ° 0
Collector field yield [Qsol] kWh 2,968

Photovoltaics Roof plan 1 KPV 260 PE NEC


Manufacturer Kioto Photovoltaics
Data Source Photovoltaikforum
Number of modules 8
Total nominal power generator field kW 2.08
Total gross area m² 13.2
Tilt angle (hor.=0°, vert.=90°) ° 36
Orientation (E=+90°, S=0°, W=-90°) ° 0
Layout 1: Number of inverters 1
Layout 1: A number of strings 1
Layout 1: A modules per string 8
Energy production DC [Qpvf] kWh 2,412
Energy production AC [Qinv] kWh 2,284
Specific annual yield kWh 1,098

Storage tank
DHW400
with RLGHE
Volume l 400

4 / 7 V10.1.5.25637 / 14.12.2018 / 19:20:13


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Solar thermal energy to the system [Qsol] kWh

Solar fraction: fraction of solar energy to system [SFn] %

5 / 7 V10.1.5.25637 / 14.12.2018 / 19:20:13


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Total fuel and/or electricity consumption of the system [Etot] kWh

Yield Photovoltaics AC [Qinv] kWh

6 / 7 V10.1.5.25637 / 14.12.2018 / 19:20:13


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.
Partner Report - Solar calculator

Collector Daily maximum temperature [ °C]

Energy flow diagram (annual balance)

7 / 7 V10.1.5.25637 / 14.12.2018 / 19:20:13


The results are based on your project input data and the average climate data for the location. A different user behaviour respectively energy demand profile
as well as local changes in the climate may influence the results. SONNENKRAFT respectively Vela Solaris AG do not accept any liability for the correctness
of the specifications and the results.