APM30H&TMC11H&IBBS200D/T

V200R303

User Guide

Issue 03
Date 2009-12-30

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd.
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any
assistance, please contact our local office or company headquarters.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com
Email: support@huawei.com

Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are the property of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide Contents

Contents

About This Document.....................................................................................................................1


1 Changes in the APM30H&TMC11H&IBBS200D/T User Guide.......................................1-1
2 Overview of the APM30H Family...........................................................................................2-1
2.1 Functions of the APM30H, IBBS200T, IBBS200D, and TMC11H...............................................................2-2
2.2 Application Scenarios of the APM30H Family..............................................................................................2-6
2.3 Technical Specifications of the APM30H Family..........................................................................................2-8
2.3.1 Electrical Specifications of the APM30H and TMC11H.......................................................................2-9
2.3.2 Engineering Specifications of the APM30H, IBBS200T, IBBS200D, and TMC11H........................2-11
2.3.3 Surge Protection Specifications of the APM30H.................................................................................2-15
2.3.4 Environmental Requirements of the APM30H, IBBS200T, IBBS200D, and TMC11H.....................2-16

3 Overview of the APM30H........................................................................................................3-1


3.1 Exterior of the APM30H.................................................................................................................................3-2
3.2 Structure of the APM30H...............................................................................................................................3-2
3.3 Cable Connections of the APM30H................................................................................................................3-3
3.4 APM30H Components....................................................................................................................................3-5
3.4.1 Fan Box..................................................................................................................................................3-6
3.4.2 AC/DC Power System..........................................................................................................................3-13
3.4.3 DC/DC Power System..........................................................................................................................3-21
3.4.4 Core of the Heat Exchanger.................................................................................................................3-25
3.4.5 Junction Box.........................................................................................................................................3-26
3.4.6 ELU......................................................................................................................................................3-27
3.4.7 Door Status Sensor...............................................................................................................................3-28
3.4.8 Heater...................................................................................................................................................3-29
3.4.9 SOU......................................................................................................................................................3-29
3.5 APM30H Cables...........................................................................................................................................3-31
3.5.1 PGND Cable.........................................................................................................................................3-32
3.5.2 Power Input Cables for the APM30H..................................................................................................3-32
3.5.3 Power Cable for the SOU.....................................................................................................................3-34
3.5.4 Power Cable for the Heater..................................................................................................................3-35
3.5.5 Power Cable for the Fan Box in the APM30H.....................................................................................3-36
3.5.6 ELU Signal Cable.................................................................................................................................3-36
3.5.7 APM30H Door Status Monitoring Cable.............................................................................................3-37

Issue 03 (2009-12-30) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
Contents User Guide

3.5.8 Transfer Cable for the Fan on the Front Door......................................................................................3-38


3.5.9 Environment Monitoring Signal Cable................................................................................................3-38
3.5.10 Monitoring Signal Transfer Cable......................................................................................................3-40

4 Overview of the IBBS200T.......................................................................................................4-1


4.1 Exterior of the IBBS200T...............................................................................................................................4-2
4.2 Structure of the IBBS200T..............................................................................................................................4-2
4.3 Cable Connections of the IBBS200T..............................................................................................................4-3
4.4 IBBS200T Components..................................................................................................................................4-4
4.4.1 TEC Cooler............................................................................................................................................4-5
4.4.2 Power Distribution Box..........................................................................................................................4-6
4.4.3 CMUA....................................................................................................................................................4-7
4.4.4 Battery..................................................................................................................................................4-11
4.5 IBBS200T Cables..........................................................................................................................................4-12
4.5.1 PGND Cable.........................................................................................................................................4-12
4.5.2 Equipotential Cable..............................................................................................................................4-13
4.5.3 Power Cables for the Batteries.............................................................................................................4-14
4.5.4 Power Cables for the TEC Cooler........................................................................................................4-15
4.5.5 Monitoring Signal Cable for the Battery Cabinet................................................................................4-16

5 Overview of the IBBS200D.......................................................................................................5-1


5.1 Exterior of the IBBS200D...............................................................................................................................5-2
5.2 Structure of the IBBS200D.............................................................................................................................5-2
5.3 Cable Connections of the IBBS200D..............................................................................................................5-3
5.4 IBBS200D Components..................................................................................................................................5-4
5.4.1 Fan Box..................................................................................................................................................5-5
5.4.2 Power Distribution Box..........................................................................................................................5-5
5.4.3 CMUA....................................................................................................................................................5-7
5.4.4 Battery..................................................................................................................................................5-11
5.4.5 Heating Film.........................................................................................................................................5-12
5.5 IBBS200D Cables.........................................................................................................................................5-13
5.5.1 PGND Cable.........................................................................................................................................5-13
5.5.2 Equipotential Cable..............................................................................................................................5-14
5.5.3 Power Cables for the Batteries.............................................................................................................5-15
5.5.4 Power Cables for the Fans in the IBBS200D.......................................................................................5-16
5.5.5 Power Cable for the Heating Film........................................................................................................5-17
5.5.6 Monitoring Signal Cable for the Battery Cabinet................................................................................5-17

6 Overview of the TMC11H........................................................................................................ 6-1


6.1 Exterior of the TMC11H.................................................................................................................................6-2
6.2 Structure of the TMC11H...............................................................................................................................6-2
6.3 Cable Connections of the TMC11H................................................................................................................6-3
6.4 TMC11H Components....................................................................................................................................6-4
6.4.1 Fan Box..................................................................................................................................................6-4

ii Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide Contents

6.4.2 DCDU-03.............................................................................................................................................6-11
6.4.3 Heater...................................................................................................................................................6-13
6.5 TMC11H Cables...........................................................................................................................................6-14
6.5.1 Equipotential Cable..............................................................................................................................6-14
6.5.2 Input Power Cable for the TMC11H....................................................................................................6-15
6.5.3 Power Cable for the Fan Box in the TMC11H.....................................................................................6-15
6.5.4 ELU Signal Cable.................................................................................................................................6-16
6.5.5 Door Status Monitoring Cable.............................................................................................................6-17
6.5.6 Transfer Cable for the Fan on the Front Door......................................................................................6-17

7 SLPU.............................................................................................................................................7-1
7.1 Structure of SLPU...........................................................................................................................................7-2
7.2 Board Configuration of the SLPU...................................................................................................................7-2
7.3 UELP...............................................................................................................................................................7-3
7.4 UFLP...............................................................................................................................................................7-5
7.5 USLP2.............................................................................................................................................................7-5

8 Maintaining the APM30H Hardware.....................................................................................8-1


8.1 Routine Maintenance.......................................................................................................................................8-3
8.2 Querying Board Information...........................................................................................................................8-3
8.3 Replacing the PMU.........................................................................................................................................8-4
8.4 Replacing the PSU..........................................................................................................................................8-7
8.5 Replacing the EPS Subrack.............................................................................................................................8-9
8.6 Replacing the AC Surge Protector................................................................................................................8-12
8.7 Replacing the Alarm Warning Fuse..............................................................................................................8-13
8.8 Replacing the Fan Box in the APM30H .......................................................................................................8-16
8.9 Replacing the Fan on the Front Door of the APM30H.................................................................................8-18
8.10 Replacing the Heater...................................................................................................................................8-21
8.11 Replacing the Fan Box in the TMC11H......................................................................................................8-23
8.12 Replacing the Batteries................................................................................................................................8-24
8.13 Replacing the TEC Cooler of the IBBS200T..............................................................................................8-27
8.14 Replacing the Fan on the Front Door of the IBBS200D.............................................................................8-30
8.15 Replacing the CMUA..................................................................................................................................8-33
8.16 Replacing the ELIA.....................................................................................................................................8-37

Index.................................................................................................................................................i-1

Issue 03 (2009-12-30) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide Figures

Figures

Figure 2-1 APM30H (stacked on the battery cabinet) working with a distributed base station..........................2-7
Figure 2-2 APM30H working with a separated macro base station.....................................................................2-8
Figure 3-1 Exterior of the APM30H....................................................................................................................3-2
Figure 3-2 Internal structure of the APM30H......................................................................................................3-3
Figure 3-3 Cable connections of the APM30H working with a distributed base station.....................................3-4
Figure 3-4 Cable connections of the APM30H working with a separated macro base station............................3-5
Figure 3-5 Fan Box...............................................................................................................................................3-6
Figure 3-6 Fan......................................................................................................................................................3-7
Figure 3-7 HPMI..................................................................................................................................................3-8
Figure 3-8 Ports on the panel of the HPMI..........................................................................................................3-8
Figure 3-9 Ports on the CMUA............................................................................................................................3-9
Figure 3-10 DIP switches on the CMUA...........................................................................................................3-12
Figure 3-11 Bit settings of the CMUA in different cabinets..............................................................................3-12
Figure 3-12 Structure of the EPS subrack in a distributed base station.............................................................3-13
Figure 3-13 Structure of the EPS subrack in a separated macro base station....................................................3-14
Figure 3-14 Exterior of the PMU.......................................................................................................................3-16
Figure 3-15 Ports on the front panel of the PMU...............................................................................................3-17
Figure 3-16 Rear panel of the PMU...................................................................................................................3-17
Figure 3-17 DIP switch on the PMU..................................................................................................................3-19
Figure 3-18 Panel of the PSU (AC/DC).............................................................................................................3-20
Figure 3-19 DC/DC power system.....................................................................................................................3-22
Figure 3-20 Panel of the PSU (DC/DC).............................................................................................................3-23
Figure 3-21 Power Subrack (DC/DC)................................................................................................................3-24
Figure 3-22 Exterior of the core of the heat exchanger......................................................................................3-26
Figure 3-23 Junction box....................................................................................................................................3-26
Figure 3-24 Structure of the junction box..........................................................................................................3-27
Figure 3-25 ELU................................................................................................................................................3-28
Figure 3-26 Magnet part of the door status sensor.............................................................................................3-28
Figure 3-27 Switch part of the door status sensor..............................................................................................3-29
Figure 3-28 Heater..............................................................................................................................................3-29
Figure 3-29 SOU................................................................................................................................................3-30
Figure 3-30 Different types of sockets...............................................................................................................3-31
Figure 3-31 PGND cable for the cabinet............................................................................................................3-32

Issue 03 (2009-12-30) Huawei Proprietary and Confidential v


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
Figures User Guide

Figure 3-32 PGND cable for the modules..........................................................................................................3-32


Figure 3-33 220 V AC single-phase power input cable.....................................................................................3-33
Figure 3-34 +24 V DC power cable...................................................................................................................3-33
Figure 3-35 Power cable for the SOU................................................................................................................3-34
Figure 3-36 Power cable for the heater..............................................................................................................3-35
Figure 3-37 Power cable for the fan box in the APM30H.................................................................................3-36
Figure 3-38 ELU signal cable............................................................................................................................3-36
Figure 3-39 APM30H door status monitoring cable..........................................................................................3-37
Figure 3-40 transfer cable for the fan on the front door.....................................................................................3-38
Figure 3-41 Environment monitoring signal cable.............................................................................................3-39
Figure 3-42 Monitoring signal transfer cable.....................................................................................................3-40
Figure 4-1 Exterior of the IBBS200T...................................................................................................................4-2
Figure 4-2 Internal structure of the IBBS200T....................................................................................................4-3
Figure 4-3 Cable connections of the IBBS200T..................................................................................................4-4
Figure 4-4 TEC cooler..........................................................................................................................................4-5
Figure 4-5 PDB.................................................................................................................................................... 4-6
Figure 4-6 External structure of the PDB.............................................................................................................4-7
Figure 4-7 Ports on the CMUA............................................................................................................................4-8
Figure 4-8 DIP switches on the CMUA.............................................................................................................4-10
Figure 4-9 Bit settings of the CMUA in different cabinets................................................................................4-11
Figure 4-10 Battery............................................................................................................................................4-11
Figure 4-11 PGND cable for the cabinet............................................................................................................4-13
Figure 4-12 PGND cable for the modules..........................................................................................................4-13
Figure 4-13 Equipotential cable.........................................................................................................................4-14
Figure 4-14 Input power cables for the batteries................................................................................................4-14
Figure 4-15 Power cable between the batteries and the copper bar in the junction box....................................4-15
Figure 4-16 Inter-battery connection copper bar................................................................................................4-15
Figure 4-17 Input power cable for the TEC cooler............................................................................................4-15
Figure 4-18 Power transfer cable for the TEC cooler........................................................................................4-16
Figure 4-19 Monitoring signal cable for the battery cabinet..............................................................................4-16
Figure 5-1 Exterior of the IBBS200D..................................................................................................................5-2
Figure 5-2 Internal structure of the IBBS200D....................................................................................................5-3
Figure 5-3 Cable connections of the IBBS200D..................................................................................................5-4
Figure 5-4 Fan box...............................................................................................................................................5-5
Figure 5-5 PDB.................................................................................................................................................... 5-6
Figure 5-6 External structure of the PDB.............................................................................................................5-7
Figure 5-7 Ports on the CMUA............................................................................................................................5-8
Figure 5-8 DIP switches on the CMUA.............................................................................................................5-10
Figure 5-9 Bit settings of the CMUA in different cabinets................................................................................5-11
Figure 5-10 Battery............................................................................................................................................5-11
Figure 5-11 Heating film....................................................................................................................................5-12
Figure 5-12 PGND cable for the cabinet............................................................................................................5-14

vi Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide Figures

Figure 5-13 PGND cable for the modules..........................................................................................................5-14


Figure 5-14 Equipotential cable.........................................................................................................................5-15
Figure 5-15 Input power cables for the batteries................................................................................................5-15
Figure 5-16 Power cable between the batteries and the copper bar in the junction box....................................5-16
Figure 5-17 Inter-battery connection copper bar................................................................................................5-16
Figure 5-18 Input power cable for the fans in the IBBS200D...........................................................................5-16
Figure 5-19 Power transfer cable for the fans in the IBBS200D.......................................................................5-17
Figure 5-20 Power cable for the heating film.....................................................................................................5-17
Figure 5-21 Monitoring signal cable for the battery cabinet..............................................................................5-18
Figure 6-1 TMC11H.............................................................................................................................................6-2
Figure 6-2 Internal structure of the TMC11H......................................................................................................6-3
Figure 6-3 Cable connections of the TMC11H....................................................................................................6-4
Figure 6-4 Fan Box...............................................................................................................................................6-5
Figure 6-5 Fan......................................................................................................................................................6-5
Figure 6-6 HPMI..................................................................................................................................................6-6
Figure 6-7 Ports on the panel of the HPMI..........................................................................................................6-7
Figure 6-8 Ports on the CMUA............................................................................................................................6-8
Figure 6-9 DIP switches on the CMUA.............................................................................................................6-10
Figure 6-10 Bit settings of the CMUA in different cabinets..............................................................................6-11
Figure 6-11 DCDU-03........................................................................................................................................6-11
Figure 6-12 Ports on the panel of the DCDU-03................................................................................................6-12
Figure 6-13 Heater..............................................................................................................................................6-13
Figure 6-14 Equipotential cable.........................................................................................................................6-14
Figure 6-15 Input power cable for the TMC11H (1)..........................................................................................6-15
Figure 6-16 Input power cable for the TMC11H (2)..........................................................................................6-15
Figure 6-17 Power cable for the fan box in the TMC11H.................................................................................6-16
Figure 6-18 ELU signal cable............................................................................................................................6-16
Figure 6-19 door status monitoring cable...........................................................................................................6-17
Figure 6-20 transfer cable for the fan on the front door.....................................................................................6-17
Figure 7-1 Structure of SLPU..............................................................................................................................7-2
Figure 7-2 Slots of the SLPU...............................................................................................................................7-2
Figure 7-3 Panel of the UELP .............................................................................................................................7-3
Figure 7-4 DIP switch on the UELP ...................................................................................................................7-4
Figure 7-5 Panel of the UFLP..............................................................................................................................7-5
Figure 7-6 Panel of the USLP2............................................................................................................................7-5
Figure 7-7 DIP switches on the USLP2...............................................................................................................7-6
Figure 8-1 ............................................................................................................................................................8-4
Figure 8-2 Installation position of the PMU........................................................................................................8-4
Figure 8-3 Removing the PMU............................................................................................................................8-5
Figure 8-4 Setting DIP switches ..........................................................................................................................8-6
Figure 8-5 Installing the PMU..............................................................................................................................8-7
Figure 8-6 Installation position of the PSU..........................................................................................................8-8

Issue 03 (2009-12-30) Huawei Proprietary and Confidential vii


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
Figures User Guide

Figure 8-7 Removing the PSU.............................................................................................................................8-8


Figure 8-8 Installing the PSU...............................................................................................................................8-9
Figure 8-9 Replacing the EPS subrack...............................................................................................................8-11
Figure 8-10 Installation position of the AC surge protector..............................................................................8-12
Figure 8-11 Removing the surge protector.........................................................................................................8-13
Figure 8-12 Installation position of the alarm warning fuse..............................................................................8-14
Figure 8-13 Position of the extraction tool in the cabinet..................................................................................8-15
Figure 8-14 Removing the faulty fuse................................................................................................................8-15
Figure 8-15 Top view of the fan box in the APM30H.......................................................................................8-17
Figure 8-16 Removing the fan box from the APM30H.....................................................................................8-17
Figure 8-17 Installation position of the fan on the front door in the APM30H.................................................8-19
Figure 8-18 Removing the fan on the front door of the APM30H.....................................................................8-20
Figure 8-19 Removing the faulty heater.............................................................................................................8-22
Figure 8-20 Installing the new heater.................................................................................................................8-22
Figure 8-21 Top view of the fan box in the TMC11H.......................................................................................8-23
Figure 8-22 Removing the fan box from the TMC11H.....................................................................................8-24
Figure 8-23 Removing the cover plate on the batteries......................................................................................8-26
Figure 8-24 Removing cables of the batteries....................................................................................................8-26
Figure 8-25 Installation position of the TEC cooler...........................................................................................8-28
Figure 8-26 Removing the retention screws on the CMUA...............................................................................8-29
Figure 8-27 Removing the faulty TEC cooler....................................................................................................8-29
Figure 8-28 Installation position of the fan on the front door of the IBBS200D...............................................8-31
Figure 8-29 Removing the fan box of the IBBS200D........................................................................................8-32
Figure 8-30 Removing the faulty fan.................................................................................................................8-32
Figure 8-31 DIP settings and bit positions of the CMUA in different cabinets.................................................8-33
Figure 8-32 Installation position of the CMUA.................................................................................................8-34
Figure 8-33 Removing the fan box of the IBBS200D........................................................................................8-35
Figure 8-34 Removing the CMUA box of the IBBS200D.................................................................................8-35
Figure 8-35 Positions for pasting the bar codes of the CMUA..........................................................................8-36
Figure 8-36 Opening the housing of the ELU....................................................................................................8-37
Figure 8-37 Removing the faulty ELIA.............................................................................................................8-38

viii Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide Tables

Tables

Table 2-1 Functions of the APM30H...................................................................................................................2-2


Table 2-2 DC power distribution functions of the APM30H...............................................................................2-3
Table 2-3 Functions of the IBBS200T................................................................................................................. 2-5
Table 2-4 Functions of the IBBS200D.................................................................................................................2-5
Table 2-5 Functions of the TMC11H...................................................................................................................2-6
Table 2-6 Electrical specifications of the APM30H.............................................................................................2-9
Table 2-7 Electrical specifications of the TMC11H...........................................................................................2-11
Table 2-8 Engineering specifications of the APM30H......................................................................................2-12
Table 2-9 Engineering specifications of the IBBS200T.....................................................................................2-13
Table 2-10 Engineering specifications of the IBBS200D..................................................................................2-13
Table 2-11 Engineering specifications of the TMC11H....................................................................................2-14
Table 2-12 Surge protection specifications of the APM30H.............................................................................2-15
Table 2-13 Environmental requirements of the APM30H.................................................................................2-16
Table 2-14 Environmental requirements of the IBBS200T................................................................................2-17
Table 2-15 Environmental requirements of the IBBS200D...............................................................................2-18
Table 3-1 Technical specifications of the fan.......................................................................................................3-7
Table 3-2 Ports on the panel of the HPMI............................................................................................................3-8
Table 3-3 Ports on the CMUA............................................................................................................................3-10
Table 3-4 LEDs on the CMUA...........................................................................................................................3-11
Table 3-5 DC power distribution functions of the EPS subrack used for a distributed base station..................3-14
Table 3-6 DC power distribution functions of the EPS used for a separated macro base station......................3-15
Table 3-7 Ports of the PMU................................................................................................................................3-18
Table 3-8 Indicators on the panel of the PMU...................................................................................................3-18
Table 3-9 LEDs on the panel of the PSU (AC/DC)...........................................................................................3-21
Table 3-10 Components of the DC/DC power system.......................................................................................3-22
Table 3-11 LEDs on the panel of the PSU (DC/DC).........................................................................................3-23
Table 3-12 Ports and terminals on the power subrack (DC/DC)........................................................................3-25
Table 3-13 Technical specifications of the SOU................................................................................................3-30
Table 3-14 PGND cables....................................................................................................................................3-32
Table 3-15 Specifications of different types of AC power input cables.............................................................3-33
Table 3-16 Pin assignment for the wires of the power cable for the SOU.........................................................3-35
Table 3-17 Pin assignment for the wires of the power cable for the heater.......................................................3-35
Table 3-18 Pin assignment for the wires of the ELU signal cable.....................................................................3-36

Issue 03 (2009-12-30) Huawei Proprietary and Confidential ix


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
Tables User Guide

Table 3-19 Pin assignment for the wires of the transfer cable for the fan on the front door..............................3-38
Table 3-20 Pin assignment for the wires of the environment monitoring signal cable......................................3-39
Table 3-21 Pin assignment for the wires of the monitoring signal transfer cable..............................................3-41
Table 4-1 Ports on the CMUA..............................................................................................................................4-8
Table 4-2 LEDs on the CMUA...........................................................................................................................4-10
Table 4-3 Technical specifications of the battery...............................................................................................4-12
Table 4-4 PGND cables......................................................................................................................................4-13
Table 4-5 Equipotential cable.............................................................................................................................4-14
Table 4-6 Pin assignment for the wires of the monitoring signal cable for the battery cabinet.........................4-16
Table 5-1 Ports on the CMUA..............................................................................................................................5-8
Table 5-2 LEDs on the CMUA...........................................................................................................................5-10
Table 5-3 Technical specifications of the battery...............................................................................................5-12
Table 5-4 PGND cables......................................................................................................................................5-14
Table 5-5 Equipotential cable.............................................................................................................................5-15
Table 5-6 Pin assignment for the wires of the monitoring signal cable for the battery cabinet.........................5-18
Table 6-1 Technical specifications of the fan.......................................................................................................6-5
Table 6-2 Ports on the panel of the HPMI............................................................................................................6-7
Table 6-3 Ports on the CMUA..............................................................................................................................6-8
Table 6-4 LEDs on the CMUA...........................................................................................................................6-10
Table 6-5 DC power distribution functions of the DCDU-03............................................................................6-12
Table 6-6 Ports on the panel of the DCDU-03...................................................................................................6-13
Table 6-7 Equipotential cable.............................................................................................................................6-15
Table 6-8 Pin assignment for the wires of the ELU signal cable.......................................................................6-16
Table 6-9 Pin assignment for the wires of the transfer cable for the fan on the front door................................6-18
Table 7-1 Board configuration of the SLPU........................................................................................................7-3
Table 7-2 Ports on the panel of the UELP............................................................................................................7-4
Table 7-3 DIP switch on the UELP .....................................................................................................................7-4
Table 7-4 Ports on the panel of the UFLP............................................................................................................7-5
Table 7-5 Ports on the panels of the USLP2........................................................................................................7-6
Table 7-6 DIP switches on the USLP2.................................................................................................................7-6
Table 8-1 Routine maintenance items..................................................................................................................8-3

x Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide About This Document

About This Document

Purpose
This document describes the functions, specifications, hardware, and cables of the APM30H,
TMC11H, IBBS200D, and IBBS200T. It also provides instructions for the hardware installation
check and hardware maintenance.
The APM30H is the Advance Power Module (with heat-exchanger cooler).
The IBBS200T is the Integrated Battery Backup System (with TEC cooler).
The IBBS200D is the Integrated Battery Backup System (with direct cooler).
The TMC11H is the Transmission Cabinet (11 U, with heat-exchanger cooler).

Product Version
The following table lists the product version related to this document.

Product Name Product Version

APM30H&TMC11H&IBBS200D/T V200R303

Intended Audience
This document is intended for:
l Field engineers
l Site maintainers

Organization
1 Changes in the APM30H&TMC11H&IBBS200D/T User Guide
This describes the changes in the APM30H&TMC11H&IBBS200D/T User Guide.
2 Overview of the APM30H Family

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
Organization User Guide

The APM30H family consists of the APM30H, TMC11H, IBBS200T, and IBBS200D.

3 Overview of the APM30H

This describes the exterior, structure, and components of the APM30H.

4 Overview of the IBBS200T

This describes the exterior, structure, components, and cables of the IBBS200T.

5 Overview of the IBBS200D

This describes the exterior, structure, components, and cables of the IBBS200D.

6 Overview of the TMC11H

This describes the exterior, structure, components, and cables of the TMC11H.

7 SLPU

The signal lightning protection unit (SLPU), which can be optionally configured with the UFLP,
UELP, or USLP2, provides the signal surge protection.

8 Maintaining the APM30H Hardware

If the APM30H should be powered off for maintenance, the duration of the power-off state
cannot exceed 48 hours.

Conventions
Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol Description

Indicates a hazard with a high level of risk, which if not


avoided,will result in death or serious injury.

Indicates a hazard with a medium or low level of risk, which


if not avoided, could result in minor or moderate injury.

Indicates a potentially hazardous situation, which if not


avoided,could result in equipment damage, data loss,
performance degradation, or unexpected results.

Indicates a tip that may help you solve a problem or save


time.

Provides additional information to emphasize or supplement


important points of the main text.

General Conventions

The general conventions that may be found in this document are defined as follows.

2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide Organization

Convention Description

Times New Roman Normal paragraphs are in Times New Roman.

Boldface Names of files, directories, folders, and users are in


boldface. For example, log in as user root.

Italic Book titles are in italics.


Courier New Examples of information displayed on the screen are in
Courier New.

Command Conventions
The command conventions that may be found in this document are defined as follows.

Convention Description

Boldface The keywords of a command line are in boldface.

Italic Command arguments are in italics.

[] Items (keywords or arguments) in brackets [ ] are optional.

{ x | y | ... } Optional items are grouped in braces and separated by


vertical bars. One item is selected.

[ x | y | ... ] Optional items are grouped in brackets and separated by


vertical bars. One item is selected or no item is selected.

{ x | y | ... }* Optional items are grouped in braces and separated by


vertical bars. A minimum of one item or a maximum of all
items can be selected.

[ x | y | ... ]* Optional items are grouped in brackets and separated by


vertical bars. Several items or no item can be selected.

GUI Conventions
The GUI conventions that may be found in this document are defined as follows.

Convention Description

Boldface Buttons, menus, parameters, tabs, window, and dialog titles


are in boldface. For example, click OK.

> Multi-level menus are in boldface and separated by the ">"


signs. For example, choose File > Create > Folder.

Keyboard Operations
The keyboard operations that may be found in this document are defined as follows.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
Organization User Guide

Format Description

Key Press the key. For example, press Enter and press Tab.

Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt
+A means the three keys should be pressed concurrently.

Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means
the two keys should be pressed in turn.

Mouse Operations
The mouse operations that may be found in this document are defined as follows.

Action Description

Click Select and release the primary mouse button without moving
the pointer.

Double-click Press the primary mouse button twice continuously and


quickly without moving the pointer.

Drag Press and hold the primary mouse button and move the
pointer to a certain position.

4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T 1 Changes in the APM30H&TMC11H&IBBS200D/T User
User Guide Guide

APM30H&TMC11H&IBBS200D/T User Guide


1 Changes in the

This describes the changes in the APM30H&TMC11H&IBBS200D/T User Guide.

03 (2009-12-30)
This is the second commercial release.
Compared with issue 02 (2009-09-30), this issue incorporates the following changes:
l Electrical specifications of the TMC11H is modified.
l 2.3.4 Environmental Requirements of the APM30H, IBBS200T, IBBS200D, and
TMC11H is modified.
l 7.2 Board Configuration of the SLPU is modified.
l Replacing the Core of the Heat Exchanger is deleted.

02 (2009-09-30)
This is the first commercial release.

01 (2009-08-14)
This is the first trial release.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 1-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

2 Overview of the APM30H Family

About This Chapter

The APM30H family consists of the APM30H, TMC11H, IBBS200T, and IBBS200D.

2.1 Functions of the APM30H, IBBS200T, IBBS200D, and TMC11H


The APM30H, IBBS200T, IBBS200D, and TMC11H provides auxiliary solutions to the outdoor
applications of Huawei wireless products. It supplies DC power to and provides backup power
for distributed or separated base stations in outdoor scenarios. It can also be used for the outdoor
applications of the indoor BBUs and transmission equipment.
2.2 Application Scenarios of the APM30H Family
The APM30H family can work with the distributed or separated base stations, meeting the
requirements in different scenarios.
2.3 Technical Specifications of the APM30H Family
The technical specifications of the APM30H family consist of the electrical specifications,
engineering specifications, surge protection specifications, and specifications concerning the
environmental requirements.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

2.1 Functions of the APM30H, IBBS200T, IBBS200D, and


TMC11H
The APM30H, IBBS200T, IBBS200D, and TMC11H provides auxiliary solutions to the outdoor
applications of Huawei wireless products. It supplies DC power to and provides backup power
for distributed or separated base stations in outdoor scenarios. It can also be used for the outdoor
applications of the indoor BBUs and transmission equipment.

Functions of the APM30H


Table 2-1 describes the functions of the APM30H.

Table 2-1 Functions of the APM30H

Function Description

Providing space for the The APM30H provides a 5 U to 7 U space for the customer
customer equipment equipment.
l Providing a 7 U space when the APM30H is not configured with
an internal battery pack
l Providing a 5 U space when the APM30H is configured with an
internal 48 V 24 Ah battery pack

Providing backup The APM30H can connect to a single battery cabinet to support up
power to the 48 V 184 Ah battery pack or connect to two stacked battery
packs to support up to 48 V 368 Ah battery pack.

Providing built-in l The PSU converts the input AC mains power into -48 V DC
PSUs power.
l The PSU is hot-swappable.

Providing a built-in l The PMU manages the PSUs and implements the battery
PMU charging and discharging functions.
l The PMU provides RS485 communication ports and dry contact
alarm ports for remote and unattended monitoring.
l The PMU supports the battery low voltage disconnect (BLVD)
and load low voltage disconnect (LLVD) functions.
l The PMU is hot-swappable.

Supporting AC input The APM30H provides a built-in AC/DC power system, which
supports single-phase 220 V AC, three-phase 220 V AC, and dual-
live wire 110 V AC.

Distributing AC power Through the EPS, the AC power is distributed into two AC outputs:
l One output provides AC power for the SOU.
l The other output is connected to the AC power distribution box
on the left of the cabinet. Through the power distribution, four
AC outputs are provided to the heater or heating film.

2-2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Function Description

Distributing DC power For details, see Table 2-2.

Providing surge External surge protection modules for AC/DC power ports and
protection for the surge protection circuits for signal ports provide safe and reliable
power supply and surge protection and lightning protection.
signal ports

Dissipating heat Heat dissipation of the APM30H is based on the heat exchanger
system that consists of a core and two air circulation fans. This can
effectively prevent dust from entering the cabinet. The APM30H
can also work with the diesel generator.

Supporting the The grounding busbar for the cabinet and the PGND cables for the
grounding components are all connected to the grounding bar of the cabinet.

Reporting the cabinet The type of the cabinet is automatically reported through the ELU.
type automatically

Table 2-2 describes the DC power distribution functions of the APM30H.

Table 2-2 DC power distribution functions of the APM30H


Silkscre Protecti Quantit DC
en on on y Output
Applic the Compo Termina
ation DC Power Output nent l
Scenar Outp Equipme Termina Type Specific
io ut nt l ation

Distrib Six RRU LOAD8 MCB 20 A 6 Easy


uted LLVD to power
base output LOAD13 receptacle
station s (pressfit
type)
Nine TMC TMC 25 A 1 connector
BLV
D FAN unit LOAD0 Fuse 15 A 1
output BBU LOAD1 2
s and
LOAD2

TEC/FAN LOAD3 1
(in the
battery
cabinet)

TM LOAD4 5A 4
to
LOAD7

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Silkscre Protecti Quantit DC


en on on y Output
Applic the Compo Termina
ation DC Power Output nent l
Scenar Outp Equipme Termina Type Specific
io ut nt l ation

Batter BAT - MCB 100 A 1 Power


y series 120
power connector
backu (grey)
p

Separat Two RFC - MCB 80 A 2 Power


ed LLVD series 120
macro output connector
base s (blue)
station
Nine TMC TMC 25 A 1 Easy
BLV power
D FAN unit LOAD0 Fuse 15 A 1 receptacle
output BBU LOAD1 2 (pressfit
s and type)
LOAD2 connector

TEC/FAN LOAD3 1
(in the
battery
cabinet)

TM LOAD4 5A 4
to
LOAD7

Batter BAT - MCB 100 A 1 Power


y series 120
power connector
backu (grey)
p

Functions of the IBBS200T


Table 2-3 describes the functions of the IBBS200T.

2-4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Table 2-3 Functions of the IBBS200T


Function Description

Providing l When configured with 48 V 50 Ah batteries, the IBBS200T can provide


backup power DC backup power of 48 V 50 Ah or 48 V 100 Ah (by housing two battery
packs).
l When configured with 48 V 92 Ah batteries, the IBBS200T can provide
DC backup power of 48 V 92 Ah or 48 V 184 Ah (by housing two battery
packs).

Reporting the The type of the cabinet is automatically reported through the ELU.
cabinet type
automatically

Providing a The TEC cooler enables the IBBS200T to adapt to high ambient temperature
built-in TEC and maintains a proper range of temperature for the cabinet.
cooler

Monitoring the The CMUA collects the alarm signals from the components such as the door
alarm signals status sensor, temperature sensor of the battery, fan, and smoke sensor.
in a centralized Then, the CMUA transmits the alarm signals to the base station.
way

Functions of the IBBS200D


Table 2-4 describes the functions of the IBBS200D.

Table 2-4 Functions of the IBBS200D


Function Description

Providing l When configured with 48 V 50 Ah batteries, the IBBS200D can provide


backup power DC backup power of 48 V 50 Ah or 48 V 100 Ah (by housing two battery
packs).
l When configured with 48 V 92 Ah batteries, the IBBS200D can provide
DC backup power of 48 V 92 Ah or 48 V 184 Ah (by housing two battery
packs).

Reporting the The type of the cabinet is automatically reported through the ELU.
cabinet type
automatically

Providing The fans in the cabinet speed up the circulation of the air inside and outside
built-in fans the cabinet and keep the temperature in the cabinet in a proper range

Monitoring the The CMUA collects the alarm signals from the components such as the door
alarm signals status sensor, temperature sensor of the battery, fan, and smoke sensor.
in a centralized Then, the CMUA transmits the alarm signals to the base station.
way

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-5


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Functions of the TMC11H


Table 2-5 describes the functions of the TMC11H.

Table 2-5 Functions of the TMC11H


Function Description

Providing -48 The TMC11H is configured with a built-in DCDU-03 and performs the
V DC power following functions:
l Supporting one -48 V DC input
l Providing nine -48 V DC outputs (LOAD0 to LOAD8)

Providing l The TMC11H provides 11 U space for customer equipment.


space for l If the heater is installed, the TMC11H provides 10 U space for customer
customer equipment.
equipment

Reporting The TMC11H provides the following two dry contact alarm ports for remote
alarms and unmanned monitoring: One of the dry contact alarm ports is connected
to the door status sensor. An open circuit indicates that the connection is
faulty, whereas a closed circuit indicates that the connection is normal.

Reporting the The type of the cabinet is automatically reported through the ELU.
cabinet type
automatically

2.2 Application Scenarios of the APM30H Family


The APM30H family can work with the distributed or separated base stations, meeting the
requirements in different scenarios.

APM30H Working with a Distributed Base Station


The scenario in which the APM30H works with a distributed base station is as follows:
l The APM30H provides the 7 U space for the BBU and transmission equipment. The built-
in power system of the APM30H supplies -48 V DC power to the distributed base station
and transmission equipment and charges the batteries in the battery cabinet.
l When the mains power is unavailable, the batteries in the IBBS200T supplies -48 V DC
power to the distribution base station and transmission equipment.
Figure 2-1 shows the scenario in which the APM30H stacked on the battery cabinet works with
a distributed base station.

2-6 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Figure 2-1 APM30H (stacked on the battery cabinet) working with a distributed base station

NOTE
When the APM30H works with a distributed base station, it can be configured with the IBBS200D or
IBBS200T. The Figure 2-1 takes the IBBS200D as an example.

APM30H working with a separated macro base station


The scenario in which the APM30H works with a separated macro base station is described as
follows:
l The APM30H provides a 7 U space for the BBU and transmission equipment. The built-
in power system of the APM30H supplies -48 V DC power to the BBU, RFU, and
transmission equipment and charges the batteries in the battery cabinet.
l The APM30H reports the alarms related to fans, door status, DCDU, and batteries in the
battery cabinet.
Figure 2-2 shows the scenarios in which the APM30H works with separated macro base stations.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-7


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Figure 2-2 APM30H working with a separated macro base station

NOTE
When the APM30H works with a separated macro base station, it can be configured with the IBBS200D
or IBBS200T. Figure 2-1 takes the IBBS200D as an example.

2.3 Technical Specifications of the APM30H Family


The technical specifications of the APM30H family consist of the electrical specifications,
engineering specifications, surge protection specifications, and specifications concerning the
environmental requirements.

2.3.1 Electrical Specifications of the APM30H and TMC11H


The electrical specifications involve AC input, DC output, protection, and Permissible heat
consumption in the cabinet.
2.3.2 Engineering Specifications of the APM30H, IBBS200T, IBBS200D, and TMC11H
The engineering specifications involve the cabinet weight, cabinet dimensions, base dimensions,
space for the customer equipment, space for cabling and maintenance space in front of the
cabinet, and installation options.
2.3.3 Surge Protection Specifications of the APM30H
The surge protection specifications of the APM30H involve the surge protection for the AC
input port, surge protection for the DC output port, and surge protection for signal ports.
2.3.4 Environmental Requirements of the APM30H, IBBS200T, IBBS200D, and TMC11H
The environmental requirements involve the operating temperature, relative humidity, altitude,
and storage temperature.

2-8 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

2.3.1 Electrical Specifications of the APM30H and TMC11H


The electrical specifications involve AC input, DC output, protection, and Permissible heat
consumption in the cabinet.

Electrical Specifications of the APM30H


Table 2-6 describes the electrical specifications of the APM30H.

Table 2-6 Electrical specifications of the APM30H


Item Specification

AC Typical 200 V AC to 240 V AC (single-phase 220 V AC)


input input
voltage 200 V AC to 240 V AC or 346 V AC to 415 V AC (three-phase 220 V
AC or 380 V AC)

100 V AC to 120 V AC or 200 V AC to 240 V AC (dual-live-wire 110


V AC)

120 V AC to 127 V AC or 208 V AC to 220 V AC (dual-live-wire 120


V AC)

Operating 176 V AC to 290 V AC (single-phase 220 V AC)


voltage
range 176 V AC to 290 V AC or 304 V AC to 500 V AC (three-phase 220 V
AC)

90 V AC to 135 V AC or 180 V AC to 270 V AC (dual-live-wire 110 V


AC)

105 V AC to 150 V AC or 176 V AC to 260 V AC (dual-live-wire 120


V AC)

Frequenc 50 Hz or 60 Hz
y of the
input
voltage

Maximu 16 A (three-phase 220 V AC or 380 V AC)


m input
current 40 A (dual-live-wire 110 V AC, dual-live-wire 120 V AC, or single-phase
220 V AC)

Input l Three-phase 220 V AC or 380 V AC


mode l Dual-live-wire 110 V AC
l Dual-live-wire 120 V AC
l Single-phase 220 V AC

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-9


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Item Specification

AC input The AC input power varies according to AC load.


power l When the PSU is configured: ≤ 5,274 W
l When the PSU, heater, and heating film are configured: ≤ 6,074 W
l When the PSU, heater, heating film, and SOU are configured: ≤ 8,274
W

DC Output -43.2 V DC to -57 V DC


outp voltage
ut range

Output l When two PSUs are configured: 0 A to 60 A


current l When three PSUs are configured: 0 A to 90 A
range

Typical -53.5 V DC
output
voltage

Number The number of DC outputs varies according to application scenario.


of DC l When working with a distributed base station: 16 DC outputs
outputs
l When working with a separated base station: 12 DC outputs

DC ≤ 3,200 W (two active PSUs and + one standby PSU)


output
power

Prote Input l Overvoltage protection: The system generates an alarm when the input
ction protectio voltage reaches the AC overvoltage alarm threshold, which is 280 V
n by default.
l Undervoltage protection: The system generates an alarm when the
input voltage is lower than the AC undervoltage alarm threshold,
which is 180 V by default.

Output l Overvoltage protection: The system generates an alarm when the


protectio busbar voltage reaches the DC overvoltage alarm threshold, which is
n -58 V by default.
l Undervoltage protection: The system generates an alarm when the
busbar voltage is lower than the DC undervoltage alarm threshold,
which is -45 V by default.
l Overcurrent protection and short-circuit protection

Permissible heat ≤ 700 W


consumption in
the cabinet

Electrical specifications of the TMC11H


Table 2-7 describes the electrical specifications of the TMC11H.

2-10 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Table 2-7 Electrical specifications of the TMC11H


Item Specification

DC input Input voltage -38.4 V DC to -57 V DC


range

Typical input -53.5 V DC


voltage

Maximum input 21 A
current

Input mode -48 V DC power input, supporting M6 2-hole OT


terminals

DC input power ≤ 800 W

DC output DC distribution Nine -48 V DC outputs: LOAD0 to LOAD8 for the


customer equipment
NOTE
When configured with different types of DCDU-03, the
TMC11H can meet different current requirements.

Typical output -48 V DC


voltage

Protection Overcurrent and short-circuit protection for DC power


distribution

Permissible heat consumption in ≤ 700 W


the cabinet

2.3.2 Engineering Specifications of the APM30H, IBBS200T,


IBBS200D, and TMC11H
The engineering specifications involve the cabinet weight, cabinet dimensions, base dimensions,
space for the customer equipment, space for cabling and maintenance space in front of the
cabinet, and installation options.

Engineering Specifications of the APM30H


Table 2-8 describes the engineering specifications of the APM30H.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-11


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Table 2-8 Engineering specifications of the APM30H


Item Specification Remarks

Weight ≤ 72 kg Total weight of the equipment


l Including the cabinet frame, inner air
circulation fan, outer air circulation fan, core of
the heart exchanger, EPS4890B-4830A, and
cables
l Excluding the BBU, transmission equipment of
the customer, PMU, and PSU

≤ 91 kg Weight of the cabinet in full configuration


l Including the equipment, one PMU, three
PSUs, and one BBU
l Excluding the transmission equipment of the
customer

Dimensions of 600 mm x 700 mm x The base is not included.


the cabinet 480 mm
(width x height x
depth)

Dimensions of 600 mm x 200 mm x -


the base (width x 434 mm
height x depth)

Space for the 482.6 mm x 311.15 l The depth refers to the spacing between the
customer mm x 310 mm (19- column and the rear side of the cabinet.
equipment inch x 7 U x 310 mm l The depth of the 3 U space at the bottom of the
(width x height x or 290 mm) cabinet is 290 mm, and heat dissipation from
depth) the back of the customer equipment is not
supported.

Space for cabling ≥ 70 mm -


and maintenance
space in front of
the cabinet

Installation The APM30H can When installed in stack mode, the APM30H
option be installed on the should be placed on the RFC or the IBBS200D/
ground, on a wall, or IBBS200T.
on a pole, or stacked
with the RFC or the
IBBS200D/
IBBS200T.

Engineering Specifications of the IBBS200T


Table 2-9 describes the engineering specifications of the IBBS200T.

2-12 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Table 2-9 Engineering specifications of the IBBS200T


Item Specification Remarks

Cabinet weight ≤ 70 kg Built-in batteries are not


configured.

Battery weight Supporting front maintenance of Two 48 V 92 Ah battery packs can


48 V 50 Ah or 48 V 92 Ah batteries be connected in parallel to provide
l A single 12 V 50 Ah battery: 48 V 184 Ah backup power.
21.5 kg
l A single 12 V 92 Ah battery:
33.5 kg
NOTE
The batteries of different
manufacturers may have different
weights. The following description is
based on common batteries.

Dimensions of the 600 mm x 700 mm x 480 mm Excluding the 206 mm that is


cabinet (width x stretched out of the cabinet on the
height x depth) front door.

Base dimensions 600 mm x 200 mm x 480 mm -


(width x height x
depth)

Installation option The IBBS200T can be installed on When installed in stack mode, the
the ground or stacked with the IBBS200T should be placed below
TMC11H or APM30H. the TMC11H or APM30H.

Engineering Specifications of the IBBS200D


Table 2-10 describes the engineering specifications of the IBBS200D.

Table 2-10 Engineering specifications of the IBBS200D


Item Specification Remarks

Cabinet weight ≤ 50 kg Built-in batteries are not


configured.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-13


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Item Specification Remarks

Battery weight Supporting front maintenance of Two 48 V 92 Ah battery packs can


48 V 50 Ah or 48 V 92 Ah batteries be connected in parallel to provide
l A single 12 V 50 Ah battery: 48 V 184 Ah backup power.
21.5 kg
l A single 12 V 92 Ah battery:
33.5 kg
NOTE
The batteries of different
manufacturers may have different
weights. The following description is
based on common batteries.

Dimensions of the 600 mm x 700 mm x 480 mm -


cabinet (width x
height x depth)

Base dimensions 600 mm x 200 mm x 480 mm


(width x height x
depth)

Installation option The IBBS200D can be installed on When installed in stack mode, the
the ground or stacked with the RFC IBBS200D should be placed below
or APM30H. the RFC or APM30H.

Engineering Specifications of the TMC11H


Table 2-11 describes the engineering specifications of the TMC11H.

Table 2-11 Engineering specifications of the TMC11H


Item Specification Remarks

Weight ≤ 57 kg Total weight of the


equipment
l Including the
cabinet frame, fan
box, and core of the
heart exchanger
l Excluding the BBU
and transmission
equipment of the
customer

Dimensions of 600 mm x 700 mm x 480 mm The appearance and


the cabinet base of the TMC11H
(width x height x are the same as those of
depth) the APM30H.

2-14 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Item Specification Remarks

Base dimensions 600 mm x 200 mm x 480 mm


(width x height x
depth)

Space for the 482.6 mm x 488.95 mm x 310 mm (19-inch x l The depth refers to
customer 11 U x 310 mm) the spacing between
equipment (width the column and the
x height x depth) rear side of the
cabinet.
l The depth of the 3 U
space at the bottom
of the cabinet is 290
mm, and heat
dissipation from the
back of the
customer
equipment is not
supported.

Space for cabling ≥ 70 mm -


and maintenance
space in front of
the cabinet

Installation The TMC11H can be installed on the ground or When installed in


option on a pole or stacked with the RFC or the stack mode, the
IBBS200D/IBBS200T. TMC11H should be
placed on the RFC or
the IBBS200D/
IBBS200T.

2.3.3 Surge Protection Specifications of the APM30H


The surge protection specifications of the APM30H involve the surge protection for the AC
input port, surge protection for the DC output port, and surge protection for signal ports.

Surge Protection Specifications of the APM30H


Table 2-12 describes the surge protection specifications of the APM30H.

Table 2-12 Surge protection specifications of the APM30H

Item Specification

Surge protection for the AC In differential mode:


input port l Nominal through-current capacity In (8/20 µs) 25 kA
l Maximum through-current capacity Imax (8/20 µs) 60 kA

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-15


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Item Specification

In common mode:
l Nominal through-current capacity In (8/20 µs) 25 kA
l Maximum through-current capacity Imax (8/20 µs) 60 kA

Surge protection for the DC l In differential mode (8/20 µs): 10 kA


output port l In common mode (8/20 µs): 15 kA
The DC output corresponds to the secondary load.
NOTE
The surge protection class for the shielding layer of the RRU power
cable is 40 kA.

Surge protection for signal E1/T1 port:


ports l In differential mode (8/20 µs): 3 kA
l In common mode (8/20 µs): 5 kA
FE port:
l In differential mode (8/20 µs): 1 kA
l In common mode (8/20 µs): 2 kA

2.3.4 Environmental Requirements of the APM30H, IBBS200T,


IBBS200D, and TMC11H
The environmental requirements involve the operating temperature, relative humidity, altitude,
and storage temperature.

Environmental Requirements of the APM30H


The APM30H can be used outdoors. Table 2-13 describes the environmental requirements of
the APM30H.

Table 2-13 Environmental requirements of the APM30H


Item Specification Remarks

Operating -40oC to +50oC (with solar radiation When the APM30H works under
temperatur of 1,120 ± 10% W/m2) -20oC, a heater needs to be configured.
e NOTE
The operating temperature for configuring
a heater refers to the average of the local
lowest temperatures for a month in a year.

Relative 5% RH to 100% RH -
humidity

2-16 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Item Specification Remarks

Altitude -60 m to +4,000 m Above the altitude of 3,000 m, the


maximum operating temperature
decreases by 1oC each time the altitude
increases by 100 m.

Wind ≤ 67 m/s -
speed

Storage -40oC to +70oC -


temperatur
e

Dustproof IP55 -
and
waterproof
specificati
on

Noise - Complying with the ETS 300 753 4.1E


standard (in a rural scenario)

Environmental Requirements of the IBBS200T


The IBBS200T can be used outdoors. Table 2-14 describes the environmental requirements of
the IBBS200T.

Table 2-14 Environmental requirements of the IBBS200T


Item Specification Remarks

Operating -20oC to +50oC (with solar radiation -


temperatur of not more than 1,120 ± 10% W/m2)
e

Relative 5% RH to 100% RH -
humidity

Altitude -60 m to +4,000 m Above the altitude of 3,000 m, the


maximum operating temperature
decreases by 1oC each time the altitude
increases by 100 m.

Wind ≤ 67 m/s -
speed

Storage -40oC to +70oC -


temperatur
e

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-17


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
2 Overview of the APM30H Family User Guide

Item Specification Remarks

Dustproof IP55 -
and
waterproof
specificati
on

Noise - Complying with the ETS 300 753 4.1E


standard (in an urban scenario)

Environmental Requirements of the IBBS200D


The IBBS200D can be used outdoors. Table 2-15 describes the environmental requirements of
the IBBS200D.

Table 2-15 Environmental requirements of the IBBS200D

Item Specification Remarks

Operating -40oC to +45oC (with solar radiation When the IBBS200D works under
temperatur of not more than 1,120 ± 10% W/m2) -200C, a heater film needs to be
e configured.
NOTE
The operating temperature for configuring
a heating film refers to the average of the
local lowest temperatures recorded for a
month in a year.

Relative 5% RH to 100% RH -
humidity

Altitude -60 m to +4,000 m Above the altitude of 3,000 m, the


maximum operating temperature
decreases by 1oC each time the altitude
increases by 100 m.

Wind ≤ 67 m/s -
speed

Storage -40oC to +70oC -


temperatur
e

Dustproof IP35 -
and
waterproof
specificati
on

Noise - Complying with the ETS 300 753 4.1E


standard (in a rural scenario)

2-18 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 2 Overview of the APM30H Family

Environmental Requirements of the TMC11H


The TMC11H can be used outdoors. The environmental requirements of the TMC11H are the
same as those of the APM30H. For details, see Table 2-13.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 2-19


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

3 Overview of the APM30H

About This Chapter

This describes the exterior, structure, and components of the APM30H.

3.1 Exterior of the APM30H


The APM30H is brightly colored and elegantly designed. It is small in size and easy to transport.
3.2 Structure of the APM30H
The APM30H has a highly integrated and modular structure design. Thus, the cabinet is easy to
operate and maintain.
3.3 Cable Connections of the APM30H
The cables of the APM30H are power cables and signal cables.
3.4 APM30H Components
The components of the APM30H consist of the fan box, power system (AC/DC), power system
(DC/DC), core of the heat exchanger, junction box, Electronic Label Unit (ELU), heater, and
Service Outlet Unit (SOU). The heater and the SOU are optional.
3.5 APM30H Cables
The APM30H cables consist of the PGND cable, input power cable, environment monitoring
signal cable, and monitoring signal cable for the PMU.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

3.1 Exterior of the APM30H


The APM30H is brightly colored and elegantly designed. It is small in size and easy to transport.
Figure 3-1 shows exterior of the APM30H.

Figure 3-1 Exterior of the APM30H

3.2 Structure of the APM30H


The APM30H has a highly integrated and modular structure design. Thus, the cabinet is easy to
operate and maintain.
Figure 3-2 shows the internal structure of the APM30H.

3-2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Figure 3-2 Internal structure of the APM30H

(1) HPMI (2) Inner air circulation fan (3) CMUA

(4) PSU (5) Door status sensor (6) ELU

(7) EPS (8) Outer air circulation fan (9) Heat exchanger

(10) Junction box (11)PMU -

As shown in the preceding picture, the APM30H provides space as follows:


l If the heater or the SOU is not installed, the APM30H provides a 7 U space for the customer
equipment.
l If the heater or the SOU is installed, the APM30H provides a 6 U space for the customer
equipment.
l The APM30H provides a 1 U space at the top for operation and maintenance of the fan box.

3.3 Cable Connections of the APM30H


The cables of the APM30H are power cables and signal cables.

Cable Connections of the APM30H Working with a Distributed Base Station


Figure 3-3 shows the cable connections of the APM30H working with a distributed base station.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Figure 3-3 Cable connections of the APM30H working with a distributed base station

(1) 3.5.9 Environment Monitoring (2) 3.5.7 APM30H Door Status (3) 3.5.10 Monitoring Signal
Signal Cable Monitoring Cable Transfer Cable

(4) 3.5.6 ELU Signal Cable (5) 3.5.8 Transfer Cable for the (6) 3.5.5 Power Cable for the Fan
Fan on the Front Door Box in the APM30H

(7) Power cables for the batteries (8) Input power cable for the (9) Cable for the fan on the front
junction box door

(10) Power cable for the heater or - -


heating film

Cable Connections of the APM30H Working with a Separated Macro Base Station
Figure 3-4 shows the cable connections of the APM30H working with a separated macro base
station.

3-4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Figure 3-4 Cable connections of the APM30H working with a separated macro base station

(1) 3.5.9 Environment Monitoring (2) 3.5.7 APM30H Door Status (3) 3.5.10 Monitoring Signal
Signal Cable Monitoring Cable Transfer Cable

(4) 3.5.6 ELU Signal Cable (5) 3.5.8 Transfer Cable for the (6) 3.5.5 Power Cable for the Fan
Fan on the Front Door Box in the APM30H

(7) Power cables for RFC1 (8) Power cables for RFC2 (9) Power cables for the batteries

(10) Input power cable for the (11) Cable for the fan on the front (12) Power cable for the heater or
junction box door heating film

3.4 APM30H Components


The components of the APM30H consist of the fan box, power system (AC/DC), power system
(DC/DC), core of the heat exchanger, junction box, Electronic Label Unit (ELU), heater, and
Service Outlet Unit (SOU). The heater and the SOU are optional.

3.4.1 Fan Box


The fan box consists of the fan subrack, fans, HPMI, and CMUA.
3.4.2 AC/DC Power System
The AC/DC power system consists of the EPS, PMU, and PSU (AC/DC).
3.4.3 DC/DC Power System
The DC/DC power system converts +24 V DC power into -48 V DC power.
3.4.4 Core of the Heat Exchanger
The core of the heat exchanger extends the area for the exchange of the air inside and outside
the APM30H cabinet, speeding up the air circulation and effectively decreasing the working

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-5


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

temperature of the cabinet. In addition, the core of the heat exchanger keeps the dust away from
the cabinet.
3.4.5 Junction Box
The junction box divides one AC input into four AC outputs. The AC outputs are used for the
SOU and multiple heating films or heaters.
3.4.6 ELU
The Electronic Label Unit (ELU) automatically reports the information about the cabinet type,
facilitating fast troubleshooting.
3.4.7 Door Status Sensor
The door status sensor monitors the opening and closing of the front door of the cabinet.
3.4.8 Heater
The heater provides the proper operating temperature for the customer equipment working in
low temperature in the cabinet. The heater is optional.
3.4.9 SOU
The Service Outlet Unit (SOU) feeds AC power to the customer equipment. The SOU is optional.

3.4.1 Fan Box


The fan box consists of the fan subrack, fans, HPMI, and CMUA.
Figure 3-5 shows the fan box.

Figure 3-5 Fan Box

(1) Fans (2) Fan subrack (3) CMUA (4) HPMI

Fans
Fans are installed in the fan box of the cabinet. They dissipate the heat for the cabinet.

Exterior
Figure 3-6 shows a fan.

3-6 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Figure 3-6 Fan

Technical Specifications
Table 3-1 describes the technical specifications of the fan.

Table 3-1 Technical specifications of the fan

Item Specification

Dimensions (Diameter x Height) 175 mm x 69 mm

Length of the lead 450 mm


NOTE
The lead is delivered with the fan and is used for
power input and monitoring.

Definition of pins 1 to 4 of the lead l Pin 1: red, connected to the positive pole
of the power supply
l Pin 2: yellow, connected to the input of the
speed-adjusting signals
l Pin 3: blue, connected to the output of the
alarm or speed signals
l Pin 4: black, connected to the negative pole
of the power supply
NOTE
The colors of the cables of the fans vary according
to the manufacturer.

Rated voltage -48 V

Operating voltage range -36 V to -57 V

Rated current 0.52 A

Maximum current 0.77 A

Rated power 24.96 W

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-7


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Item Specification

Maximum power 36.96 W

Rated speed 3100 r/min

Speed-adjusting mode PWM mode

HPMI
The Hert Power Monitoring Interface unit (HPMI) transfers the power monitoring signals and
provides ports for the input and output of various alarm signals.

Exterior
Figure 3-7 shows the HPMI.

Figure 3-7 HPMI

Ports
Figure 3-8 shows the ports on the panel of the HPMI, and Table 3-2 describes the ports on the
panel of the HPMI.

Figure 3-8 Ports on the panel of the HPMI

- + - + - + - + - + - + - + - +
PMU_DB50 OUT0 OUT1 IN0 IN1 IN2 FUSE GATE TEM_BAT1 IN3 IN4 SMOKE WATER TEM_HUM

Table 3-2 Ports on the panel of the HPMI

Port Function

PMU_DB50 Transferring the monitoring signals of the


PMU

OUT0, OUT1 Transmitting two Boolean outputs

IN0, IN1, and IN2 Receiving three Boolean inputs

FUSE Detecting the fuse alarm signals

3-8 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Port Function

GATE Receiving the door status alarm input signals

IN3, IN4 Receiving two Boolean inputs

TEM_BAT1 Receiving the battery temperature monitoring


input

SMOKE Receiving the smoke alarm input

WATER Receiving the water damage alarm input

TEM_HUM Receiving the temperature and humidity


alarm input

CMUA
This describes the Central Monitoring Unit type A (CMUA).

Functions
The CMUA implements the following functions:

l Automatically adjusts and controls the temperature of the cabinet in different temperature
control modes.
l Reserves three ports for Boolean inputs and detects the Boolean alarms in the cabinet. The
remote detection, however, is not supported.
l Provides an RJ-45 port for the ELU and monitors the information about the cabinet type.

Ports
Figure 3-9 shows the ports on the CMUA.

Figure 3-9 Ports on the CMUA

(1) TEM/TEM_BAT port (2) COM_OUT port (3) COM_IN port (4) LEDs

(5) ELU port (6) GATE port (7) IN0 port (8) IN1 port

(9) IN2 port (10) SMOKE port (11) FAN_EXT port (12) PWR port

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-9


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

(13) Port for the TEC cooler (14) FAN1/FAN_EXT port (15) FAN2/FAN_INTT port -

Table 3-3 describes the ports on the CMUA.

Table 3-3 Ports on the CMUA


Port Description

TEM/TEM_BAT port l The port is not used in the APM30H or


TMC11H.
l The silkscreen of the port in the RFC is
TEM. The port is used for connection to
the air inlet temperature sensor.
l The silkscreen of the port in the IBBS200D
or IBBS200T is TEM_BAT. The port is
used for connection to the battery
temperature sensor.

COM_OUT port Used for connecting to the PMU or lower-


level CMUA

COM_IN port Used for connecting to the BBU or upper-


level CMUA

LEDs l RUN LED: indicates the running status of


fans.
l ALM LED: indicates the alarm status of
the fans.
Table 3-4 describes the LEDs and their
status.

ELU port Used for reporting the information about the


cabinet type

GATE port Port for the door status sensor

IN0, IN1, and IN2 ports Used for receiving three Boolean inputs

SMOKE port Port for the smoke sensor

FAN_EXT port The port is used only in the APM30H or


TMC11H. It is used for connection to the
outer air circulation fans on the front door of
the cabinet.

PWR port Used for feeding DC input power into the


board

Port for the TEC cooler The port is used only in the IBBS200T. It is
used used for connection to the TEC cooler.

3-10 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Port Description

FAN1/FAN_EXT port l The silkscreen of the port in the APM30H


or TMC11H is FAN1. The port is used for
connection to the fans in the fan box.
l The silkscreen of the port in the RFC or
IBBS200D is FAN1. The port is used for
connection to the fans on the right of the
fan box.
l The silkscreen of the port in the IBBS200T
is FAN_EXT. The port is used for
connection to the outer air circulation fans
of the TEC cooler.

FAN2/FAN_INT port l The silkscreen of the port in the RFC or


IBBS200D is FAN2. The port is used for
connection to the fans on the left of the fan
box.
l The silkscreen of the port in the IBBS200T
is FAN_INT. The port is used for
connection to the inner air circulation fans
of the TEC cooler.

LEDs
Table 3-4 describes the LEDs on the CMUA.

Table 3-4 LEDs on the CMUA


Label Color Status Description

RUN Green Blinking (ON for 1s and The board is functional, and the
OFF for 1s) communication with the main control unit is
normal.

Blinking (ON for The board is functional, but the


0.125s and OFF for communication with the main control unit
0.125s) fails. (If the board does not communicate with
the main control unit for one minute, the
communication fails.)

ON or OFF The board is faulty (it is not in the power-on


self check state).

ALM Red OFF No alarm is generated.

ON An alarm is generated, and the board needs to


be replaced.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-11


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Label Color Status Description

Blinking (ON for 1s and An alarm is generated, and the alarm may be
OFF for 1s) caused by the faults of the related boards or
ports. Therefore, whether the board needs to
be replaced cannot be determined.

DIP Switches
Three DIP switches are displayed on the CMUA panel, indicating the working modes of the
CMUA in different cabinets. Figure 3-10 shows the DIP switches on the CMUA.

Figure 3-10 DIP switches on the CMUA

Figure 3-11 shows the bit settings of the CMUA in different cabinets.

Figure 3-11 Bit settings of the CMUA in different cabinets

NOTE

The red rectangle in Figure 3-11 shows the position for connecting to the jumper cap.

3-12 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

3.4.2 AC/DC Power System


The AC/DC power system consists of the EPS, PMU, and PSU (AC/DC).

EPS Subrack
There are two types of EPS subracks, which are used for the distributed base stations and
separated macro base stations.

Structure
Figure 3-12 shows structure of the EPS subrack used in a distributed base station.

Figure 3-12 Structure of the EPS subrack in a distributed base station

(1) PMU (2) AC OUTPUT (3) AC INPUT (4) AC surge protector

(5) PSU circuit breaker (6) AC OUT1 circuit (7) AC OUT2 circuit (8) TMC circuit breaker
breaker breaker

(9) Battery circuit breaker (10) Circuit breaker (11) Fuse (12) DC output terminal

(13) Output terminal for the (14) Lithium battery (15) PSU (16) Spare part box
batteries control switch containing fuses

(17) Extraction tool - - -

Figure 3-13 shows structure of the EPS subrack used in a separated macro base station.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-13


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Figure 3-13 Structure of the EPS subrack in a separated macro base station

(1) PMU (2) AC OUTPUT (3) AC INPUT (4) AC surge protector

(5) PSU circuit breaker (6) AC OUT1 circuit (7) AC OUT2 circuit (8) Battery circuit breaker
breaker breaker

(9) TMC circuit breaker (10) RFC1 circuit breaker (11) RFC2 circuit breaker (12) Fuse

(13) DC output terminal (14) Output terminal for (15) Output terminal for (16) Output terminal for the
RFC1 RFC2 batteries

(17) Lithium battery (18) PSU (19) Spare part box (20) Extraction tool
control switch containing fuses

Functions
The EPS has the AC power distribution and DC power distribution functions.
l The EPS has the following AC power distribution functions:
– Providing two AC outputs, one for the Service Outlet Unit (SOU) and the other for the
junction box on the left of the cabinet. After the power distribution through the AC
power distribution box, four AC outputs are supplied to the heater or heating film.
– Reporting the AC input surge protection alarms.
l Providing 16/12 DC outputs for the distributed base station or separated macro base station

Table 3-5 describes the DC power distribution functions of the EPS of the APM30H used for a
distributed base station.

Table 3-5 DC power distribution functions of the EPS subrack used for a distributed base station
DC Power DC Output Protection Specificati Quantity DC Output
To... Terminal Componen on Terminal
t Type

RRU RRU Circuit 20 A 6 Easy power


breaker receptacle

3-14 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

DC Power DC Output Protection Specificati Quantity DC Output


To... Terminal Componen on Terminal
t Type

TMC TMC 25 A 1 (pressfit


type)
FAN LOAD0 Fuse 15 A 1 connector
BBU LOAD1 and 2
LOAD2

IBBS LOAD3 1

Transmissio LOAD4 to 5A 4
n equipment LOAD7

Battery - Circuit 100 A 1 120 series


breaker power
connector
(grey)

Table 3-6 describes the DC power distribution functions of the EPS of the APM30H used for a
separated macro base station.

Table 3-6 DC power distribution functions of the EPS used for a separated macro base station
DC Power DC Output Protection Specificati Quantity DC Output
To... Terminal Componen on Terminal
t Type

RFC - Circuit 80 A 2 120 series


breaker power
connector
(blue)

TMC TMC 25 A 1 Easy power


receptacle
FAN LOAD0 Fuse 15 A 1 (pressfit
BBU LOAD1 and 2 type)
LOAD2 connector

IBBS LOAD3 1

Transmissio LOAD4 to 5A 4
n equipment LOAD7

Battery - Circuit 100 A 1 120 series


breaker power
connector
(grey)

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-15


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

PMU
The Power Monitoring Unit (PMU) provides the functions of power system and battery
management, power monitoring, and alarm reporting.

Functions
The PMU performs the following functions:
l Communicates with the BBU through an RS485 serial port
l Manages the power system and charging and discharging the batteries
l Checks and reports the Boolean values of the door status sensor, and standby sensor, and
reports the analog values of the temperature and humidity, battery temperature, and standby
analog value
l Monitors the power supply and reports alarms, including dry contact alarms
l Communicates with the storage battery cabinet through an RS485 serial port

Exterior
Figure 3-14 shows exterior of the PMU.

Figure 3-14 Exterior of the PMU

Ports and Indicators


Figure 3-15 shows the ports on the front panel of the PMU. Figure 3-16 shows the rear panel
of the PMU.

3-16 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Figure 3-15 Ports on the front panel of the PMU

(1) COM_IN port (2) Indicator

(3) COM_OUT port (4) Power test port

(5) COM_485 port (6) Battery control switch

(7) COM port -

Figure 3-16 Rear panel of the PMU

(1) Backplane port

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-17


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Table 3-7 lists the ports of the PMU.

Table 3-7 Ports of the PMU


Port Function

COM_IN port Communicating with the host or superior equipment

COM_OUT port Communicating with the subordinate equipment.

COM_485 port Communicating with the storage battery cabinet.

Battery control switch With two control ports: ON and OFF. They control connection to
or disconnection from batteries.
l To connect to batteries, press and hold the ON port for 5s to 10s.
l To disconnect from batteries, press and hold the OFF port for 5s
to 10s.
NOTE
l When operating the battery control switch, you need to insert a small
round bar into the hole. When you hear a crack, the batteries are connected
or disconnected.

COM port Connected to the external signal transfer board.

Backplane port Connected to the backplane.

Table 3-8 lists the indicators on the panel of the PMU.

Table 3-8 Indicators on the panel of the PMU


Label Color Status Description

RUN Green Blinking (on for 1s and The PMU is functional and is communicating
off for 1s) with the BBU properly.

Blinking (on for 0.125s The PMU is functional, but its


and off for 0.125s) communication with the BBU fails. If the
PMU does not communicate with the BBU
for one minute, the communication is
regarded as failed.

On or off The PMU is faulty (when it is not in the


power-on self-check state).

3-18 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Label Color Status Description

ALM Red On The base station reports at least one of the


following types of alarms:
l Mains failure alarm (including mains
phase loss).
l Mains power overvoltage or undervoltage
l Busbar overvoltage or undervoltage
l Charging overcurrent
l Battery power-off alarm
l Battery group loop failure alarm
l Environmental temperature alarm
l Environmental humidity alarm
l PSU alarm
l Load power-off

Off No alarm is generated.

NOTE

Within 3s to 5s after the PMU is powered on, the ALM and RUN indicators are on at the same time for
about 3s.

DIP Switch
The DIP switch is positioned on the right panel of the PMU. The DIP switch has eight bits, which
are set to OFF before delivery. Figure 3-17 shows the DIP switch on the PMU.

Figure 3-17 DIP switch on the PMU

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-19


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

The DIP switch uses the binary method. The four least significant bits (1, 2, 3, and 4) of the DIP
switch define the secondary node address of the PMU. The four most significant bits (5, 6, 7,
and 8) are not defined and are reserved for future use.
You can set the monitoring address by setting the four least significant bits of the DIP switch.
The least significant bit corresponds to bit 0, and the fourth least significant bit corresponds to
bit 3.

NOTE

l The address monitored by the PMU is set to 3 by default. When two PMUs share the same bus, the
address monitored by the other PMU is set to 4.
l ON indicates the value 1, and OFF indicates the value 0.

PSU (AC/DC)
The Power Supply Unit (PSU) can convert 110 V AC or 220 V AC power into -48 V DC power.

Functions
The PSU (AC/DC) implements the following functions:
l Converts 110 V AC or 220 V AC into -48 V DC power
l Monitors the alarms related to module faults (such as output overvoltage, no output, and
fan faults), alarms related to module protection (such as overtemperature protection and
input overvoltage/undervoltage protection), and module out-of-position alarm

Panel
Figure 3-18 shows the panel of the PSU (AC/DC).

Figure 3-18 Panel of the PSU (AC/DC)

(1) Power LED

(2) Protection LED

(3) Fault LED

3-20 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

LEDs
Table 3-9 describes the LEDs on the panel of the PSU (AC/DC).

Table 3-9 LEDs on the panel of the PSU (AC/DC)

Label Color Status Description

Power LED Green ON The PSU is normal.

OFF There are faults (such


as no AC input, or
overvoltage and
undervoltage of AC
input) related to the
mains, or the PSU
has no output.

Protection LED Yellow OFF The PSU is normal.

ON Temperature pre-
warning

Fault LED Red OFF The PSU is normal,


or the PSU has no
output because of the
faults (such as no AC
input, or overvoltage
and undervoltage of
AC input) related to
the mains.

ON The PSU has no


output because of
output overvoltage
shutdown, fan fault,
overtemperature
shutdown, remote
shutdown, or internal
problems of the PSU.

3.4.3 DC/DC Power System


The DC/DC power system converts +24 V DC power into -48 V DC power.

Components of the DC/DC Power System


The DC/DC power system consists of the PSUs (DC/DC) and power subrack (DC/DC).

Figure 3-19 shows the DC/DC power system.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-21


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Figure 3-19 DC/DC power system

ALM PRESEN T

TERMINA
L
CONNECTION
DC DC
INPU T OUTPU T

+ LOAD-

+ LOAD-

- R TN+

- R TN+

1 2
(1) PSUs (DC/DC) (2) Power subrack (DC/DC)

Table 3-10 describes the components of the DC/DC power system.

Table 3-10 Components of the DC/DC power system


Component Description

PSU (DC/DC) For details, see PSU (DC/DC).

Power subrack (DC/DC) For details, see Power Subrack (DC/DC).

PSU (DC/DC)
The PSU is the Power Supply Unit. The PSU (DC/DC) converts +24 V DC power into -48 V
DC power.

Panel
Figure 3-20 shows the panel of the PSU (DC/DC).

3-22 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Figure 3-20 Panel of the PSU (DC/DC)

1 2 3

(1) Power LED (2) Protection LED (3) Fault LED

Functions
l Converting +24 V DC power into -48 V DC power and leading the -48 V DC power into
the DCDU-01.
l Monitoring the unit and reporting alarms related to PSU faults (such as output overvoltage,
no output, and fan faults), alarms related to PSU protection (such as overtemperature
protection, and input overvoltage/undervoltage protection), and PSU out-of-position alarm,
if any.

LEDs
Table 3-11 describes the LEDs on the panel of the PSU (DC/DC).

Table 3-11 LEDs on the panel of the PSU (DC/DC)


LED Color Status Description

Power LED Green ON Normal.

OFF There is no power


input, or the fuse is
damaged.

Protection LED Yellow OFF Normal.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-23


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

LED Color Status Description

ON There is abnormal
input or output
voltage, the inside of
the unit is
overheated, the unit
is not properly
inserted.

Fault LED Red OFF Normal.

Blinking The fan of the unit is


faulty.

Power Subrack (DC/DC)


The power subrack (DC/DC) provides the power input wiring terminals, power output wiring
terminals, ALM port, and PRESENT port. The terminals and ports are used for the connections
of the +24 V input power cables, -48 V output power cables, monitoring signal cable for the
PSU, and in-position signal cable for the PSU respectively.

Structure
Figure 3-21 shows the power subrack (DC/DC).

Figure 3-21 Power Subrack (DC/DC)

(1) Power input wiring (2) PRESENT port (3) ALM port (4) Power output wiring
terminals terminals

Ports
Table 3-12 describes the ports and terminals on the power subrack (DC/DC).

3-24 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Table 3-12 Ports and terminals on the power subrack (DC/DC)


Terminal/ Label Connector Description
Port Type

Power input DC INPUT OT terminal The + wiring terminals are used for the
wiring terminal connections of +24 V power cables, and
the - wiring terminals are used for the
connections of +24 V RTN cables.

Power output DC OT terminal The LOAD- wiring terminals are used


wiring terminal OUTPUT for the connections of the -48 V power
cables, and the RTN+ wiring terminals
are used for the connections of the -48 V
RTN cables.

Alarm signal ALM Cord end The ALM port is used for the connection
port terminals of the monitoring signal cable for the
PSU.

Present signal PRESENT RJ-45 The PRESENT port is used for the
port connection of the in-position signal
cable for the PSU.

3.4.4 Core of the Heat Exchanger


The core of the heat exchanger extends the area for the exchange of the air inside and outside
the APM30H cabinet, speeding up the air circulation and effectively decreasing the working
temperature of the cabinet. In addition, the core of the heat exchanger keeps the dust away from
the cabinet.

Exterior
The core of the heat exchanger is positioned on the inner side of the front door of the APM30H
cabinet. Figure 3-22 shows the exterior of the core of the heat exchanger.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-25


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Figure 3-22 Exterior of the core of the heat exchanger

3.4.5 Junction Box


The junction box divides one AC input into four AC outputs. The AC outputs are used for the
SOU and multiple heating films or heaters.

Exterior
The junction box is on the left inner side of the APM30H. Figure 3-23 shows the junction box.

Figure 3-23 Junction box

3-26 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Structure
Figure 3-24 shows the structure of the junction box.

Figure 3-24 Structure of the junction box

(1) L wiring terminals for four AC (2) N wiring terminals for four AC (3) PE wiring terminals for four AC
outputs outputs outputs

(4) Cable holes (5) N wiring terminals for the AC (6) L wiring terminal for the AC
input input

3.4.6 ELU
The Electronic Label Unit (ELU) automatically reports the information about the cabinet type,
facilitating fast troubleshooting.
The ELU is on the left inner side of the IBBS200D or IBBS200T or on the right inner side of
the APM30H, TMC11H, or RFC. Figure 3-25 shows the ELU.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-27


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Figure 3-25 ELU

(1) Housing (2) RJ-45 port

3.4.7 Door Status Sensor


The door status sensor monitors the opening and closing of the front door of the cabinet.
The door status sensor consists of the magnet part and switch part.
Figure 3-26 shows the magnet part of the door status sensor.

Figure 3-26 Magnet part of the door status sensor

Figure 3-27 shows the switch part of the door status sensor.

3-28 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Figure 3-27 Switch part of the door status sensor

3.4.8 Heater
The heater provides the proper operating temperature for the customer equipment working in
low temperature in the cabinet. The heater is optional.

Exterior
The heater is 1 U high. Figure 3-28 shows the heater.

Figure 3-28 Heater

Technical Specifications
The technical specifications of the heater are as follows:

l When the temperature in the cabinet is lower than 00C, the heater starts working; when the
temperature is higher than 150C, the heater stops working.
l The maximum heating power of the heater is 300 W.

3.4.9 SOU
The Service Outlet Unit (SOU) feeds AC power to the customer equipment. The SOU is optional.

Technical Specifications
Table 3-13 describes the technical specifications of the SOU.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-29


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Table 3-13 Technical specifications of the SOU


Item Specification

Dimensions (width x depth x height) 482.6 mm x 91 mm x 55 mm

Weight 1.5 kg

Input voltage range 200 V AC to 240 V AC

Maximum input current 10 A

Output voltage range 200 V AC to 240 V AC

Maximum output current 10 A

Operating frequency 50 Hz or 60 Hz

Operating temperature -400C to + 550C

Altitude ≤ 4,000 m
NOTE
Above the altitude of 3,000 m, the maximum
operating temperature decreases by 10C each time
the altitude increases by 100 m.

Protection class IP20

Exterior
Figure 3-29 shows the SOU.

Figure 3-29 SOU

(1) Power supply socket (2) MCB (3) Socket (Europe)

NOTE

The SOU can be used for different types of sockets in different countries. The types of sockets that are
supported are: North America, European standard, general-purpose, and UK types. Figure 3-30 shows the
different types of sockets.

3-30 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Figure 3-30 Different types of sockets

3.5 APM30H Cables


The APM30H cables consist of the PGND cable, input power cable, environment monitoring
signal cable, and monitoring signal cable for the PMU.

3.5.1 PGND Cable


The PGND cables consist of the PGND cable for the cabinet and PGND cables for the modules
in the cabinet.
3.5.2 Power Input Cables for the APM30H
The power input cables for the APM30H lead external power to the power system. Different
configurations of the power system can support different types of power input, including the
220 V AC single-phase power input, 220 V AC three-phase power input, 110 V AC dual live
wire power input, and +24 V DC power input.
3.5.3 Power Cable for the SOU
The input power cable feeds AC power into the SOU from the AC OUTPUT port of the EPS.
3.5.4 Power Cable for the Heater
The power cable for the heater feeds the AC input power into the heater from the junction box.
3.5.5 Power Cable for the Fan Box in the APM30H
The power cable feeds -48 V DC power into the fan box in the APM30H.
3.5.6 ELU Signal Cable
The ELU (Electronic Label Unit) signal cable transmits to the CMUA the information about the
cabinet type reported by the ELU.
3.5.7 APM30H Door Status Monitoring Cable
The APM30H door status monitoring cable transmits the alarm signals to the PMU through the
HPMI.
3.5.8 Transfer Cable for the Fan on the Front Door
The transfer cable feeds power into the fan on the front door of the APM30H or TMC11H and
transmits fan monitoring signals to the CMUA.
3.5.9 Environment Monitoring Signal Cable
The environment monitoring signal cable transmits external monitoring signals to the PMU.
3.5.10 Monitoring Signal Transfer Cable
The monitoring signal transfer cable transmits RS485 signals from the PMU to the CMUA.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-31


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

3.5.1 PGND Cable


The PGND cables consist of the PGND cable for the cabinet and PGND cables for the modules
in the cabinet.

Exterior
All PGND cables have the same exterior. Both ends of the cables are linked with OT terminals.
Figure 3-31 and Figure 3-32 show the PGND cables.

Figure 3-31 PGND cable for the cabinet

OT terminal

Figure 3-32 PGND cable for the modules

OT terminal

Cable Description
Table 3-14 describes the PGND cables.

Table 3-14 PGND cables


Cable Color Cross-Sectional Area

PGND cable for the cabinet Green and yellow 16 mm2

PGND cable for the modules Green and yellow 6 mm2


in the cabinet

3.5.2 Power Input Cables for the APM30H


The power input cables for the APM30H lead external power to the power system. Different
configurations of the power system can support different types of power input, including the
220 V AC single-phase power input, 220 V AC three-phase power input, 110 V AC dual live
wire power input, and +24 V DC power input.

3-32 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Exterior
Figure 3-33 shows the 220 V AC single-phase power input cable.

Figure 3-33 220 V AC single-phase power input cable

(1) OT terminal (6mm2, M6)

NOTE

The number of wires of an AC power input cable varies according to the cable type. Figure 3-33 shows
the 220 V AC single-phase power input cable.

Figure 3-34 shows the +24 V DC power input cable.

Figure 3-34 +24 V DC power cable

(1) OT terminal (25mm2, M6)

NOTE

A +24 V DC power input cable consists of two wires, one wire in red, and the other wire in black.

Specifications
Table 3-15 describes the specifications of different types of AC power input cables.

Table 3-15 Specifications of different types of AC power input cables

Cable Type Wire Type Wire Color Wire Diameter, OT


Aperture Type

220 V AC three- L1 wire Yellow 2.5mm2, M6


phase power cable
L2 wire Green

L3 wire Red

N wire Blue

PE Yellow green

220 V AC single- L wire Brown 6 mm2, M6


phase power cable

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-33


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

Cable Type Wire Type Wire Color Wire Diameter, OT


Aperture Type

N wire Blue

PE wire Yellow green

110 V AC dual live L1 wire Black 6 mm2, M6


wires
L2 cable Red

N White

PE wire Green

NOTE

The colors and appearance of cables delivered by Huawei vary with countries and areas. If cables are
purchased at local markets, the cables must comply with the local rules and regulations.

3.5.3 Power Cable for the SOU


The input power cable feeds AC power into the SOU from the AC OUTPUT port of the EPS.

Structure
Figure 3-35 shows the power cable for the SOU.

Figure 3-35 Power cable for the SOU

(1) OT terminal (1.5mm2, M4) (2) C13 connector

Pin Assignment
Table 3-16 shows the pin assignment for the wires of the power cable for the SOU.

3-34 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Table 3-16 Pin assignment for the wires of the power cable for the SOU

One End

Pin Wire Color Connector Type Label

X1 Brown OT terminal L

X2 Green and OT terminal PE


yellow

X3 Blue OT terminal N

3.5.4 Power Cable for the Heater


The power cable for the heater feeds the AC input power into the heater from the junction box.

Structure
Figure 3-36 shows the power cable for the heater.

Figure 3-36 Power cable for the heater

(1) OT terminal (1.5mm2, M4) (2) C13 connector

Pin Assignment
Table 3-17 describes the pin assignment for the wires of the power cable for the heater.

Table 3-17 Pin assignment for the wires of the power cable for the heater

SN Wire Color Connector Type Label

X1 Brown OT terminal L

X2 Green and OT terminal PE


yellow

X3 Blue OT terminal N

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-35


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

3.5.5 Power Cable for the Fan Box in the APM30H


The power cable feeds -48 V DC power into the fan box in the APM30H.

Structure
Figure 3-37 shows the power cable for the fan box in the APM30H.

Figure 3-37 Power cable for the fan box in the APM30H

(1) 3V3 power connector (2) Easy power receptacle (pressfit type) connector

3.5.6 ELU Signal Cable


The ELU (Electronic Label Unit) signal cable transmits to the CMUA the information about the
cabinet type reported by the ELU.

Structure
Figure 3-38 shows the ELU signal cable.

Figure 3-38 ELU signal cable

(1) RJ-45 connector

Pin Assignment
Table 3-18 describes the pin assignment for the wires of the ELU signal cable.

Table 3-18 Pin assignment for the wires of the ELU signal cable

X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

3-36 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

X1 End X2 End Wire Color Type

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

3.5.7 APM30H Door Status Monitoring Cable


The APM30H door status monitoring cable transmits the alarm signals to the PMU through the
HPMI.

Structure
Figure 3-39 shows the APM30H door status monitoring cable.

Figure 3-39 APM30H door status monitoring cable

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-37


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

APM30H door status monitoring cable:


l The cable labeled 1 is terminated with a 2-pin socket at one end, which is connected to the
HPMI. The other end of the cable is terminated with a bare wire and a cord end terminal,
which are connected to the door status sensor and wiring terminal block respectively.
l The cable labeled 2 is terminated with a bare wire at one end, which is connected to the
door status sensor. The other end of the cable is terminated with a cord end terminal, which
is connected to the wiring terminal block.
l The cable labeled 3 are terminated with cord end terminals at both ends, which are
connected to two ports at one side of the wiring terminal block.

3.5.8 Transfer Cable for the Fan on the Front Door


The transfer cable feeds power into the fan on the front door of the APM30H or TMC11H and
transmits fan monitoring signals to the CMUA.

Structure
Figure 3-40 shows the transfer cable for the fan on the front door.

Figure 3-40 transfer cable for the fan on the front door

Pin Assignment
Table 3-19 describes the pin assignment for the wires of the transfer cable for the fan on the
front door.

Table 3-19 Pin assignment for the wires of the transfer cable for the fan on the front door

Wire X1 End X2 End Color

W1 X1.1 X2.1 Black

W2 X1.2 X2.2 Black

W3 X1.3 X2.3 Black

W4 X1.4 X2.4 Black

3.5.9 Environment Monitoring Signal Cable


The environment monitoring signal cable transmits external monitoring signals to the PMU.

3-38 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Structure
The environment monitoring signal cable is black and 0.5 m long, with a DB50 male connector
at each end. Figure 3-41 shows the environment monitoring signal cable.

Figure 3-41 Environment monitoring signal cable

View A View B

1
A B

W1

W2
X1 X2

(1) DB50 male connector

Pin Assignment
Table 3-20 describes the pin assignment for the wires of the environment monitoring signal
cable.

Table 3-20 Pin assignment for the wires of the environment monitoring signal cable

X1 End X2 End Description

1 1 Single wire

3 3 Twisted pair

4 4

5 5 Twisted pair

8 8

9 9 Twisted pair

10 10

11 11 Twisted pair

12 12

13 13 Twisted pair

14 14

16 16 Twisted pair

17 17

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-39


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
3 Overview of the APM30H User Guide

X1 End X2 End Description

18 18 Twisted pair

19 19

20 20 Twisted pair

21 21

22 22 Twisted pair

23 23

24 24 Twisted pair

25 25

27 27 Twisted pair

28 28

29 29 Twisted pair

30 30

31 31 Twisted pair

32 32

33 33 Twisted pair

34 34

43 43 Twisted pair

44 44

3.5.10 Monitoring Signal Transfer Cable


The monitoring signal transfer cable transmits RS485 signals from the PMU to the CMUA.

Structure
The monitoring signal transfer cable is black and 0.6 m long, with an RJ-45 connector at each
end. Figure 3-42 shows the monitoring signal transfer cable.

Figure 3-42 Monitoring signal transfer cable

(1) RJ-45 connector

3-40 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 3 Overview of the APM30H

Pin Assignment
Table 3-21 describes the pin assignment for the wires of the monitoring signal transfer cable.

Table 3-21 Pin assignment for the wires of the monitoring signal transfer cable
X1 End X2 End Description

X1.1 X2.1 Twisted pair

X1.2 X2.2

X1.3 X2.3 Twisted pair

X1.6 X2.6

X1.4 X2.4 Twisted pair

X1.5 X2.5

X1.7 X2.7 Twisted pair

X1.8 X2.8

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 3-41


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

4 Overview of the IBBS200T

About This Chapter

This describes the exterior, structure, components, and cables of the IBBS200T.

4.1 Exterior of the IBBS200T


The IBBS200T is brightly colored and elegantly designed. It is small in size and easy to transport.
4.2 Structure of the IBBS200T
The IBBS200T has a highly integrated and modular structure design. The power distribution
box (PDB) of the IBBS200T is installed to the upper right inside the cabinet, and the CMUA is
installed on the inner side of the cabinet door.
4.3 Cable Connections of the IBBS200T
The cables of the IBBS200T are power cables and signal cables.
4.4 IBBS200T Components
The components of the IBBS200T consist of the TEC cooler, power distribution box, CMUA,
and batteries.
4.5 IBBS200T Cables
The IBBS200T cables consist of the equipotential cable, input power cables for the batteries,
power cable for the TEC cooler, and monitoring signal cable.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

4.1 Exterior of the IBBS200T


The IBBS200T is brightly colored and elegantly designed. It is small in size and easy to transport.
Figure 4-1 shows exterior of the IBBS200T.

Figure 4-1 Exterior of the IBBS200T

4.2 Structure of the IBBS200T


The IBBS200T has a highly integrated and modular structure design. The power distribution
box (PDB) of the IBBS200T is installed to the upper right inside the cabinet, and the CMUA is
installed on the inner side of the cabinet door.
Figure 4-2 shows the internal structure of the IBBS200T.

4-2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

Figure 4-2 Internal structure of the IBBS200T

(1) TEC cooler (2) CMUA (3) TEC/Battery input (4) MCBs of the TEC/
power wiring terminals FAN

(5) MCB of the batteries in (6) MCB of the batteries in (7) TEC/Battery input -
the lower part the upper part power wiring terminals

Structure of the cabinet:


l Each TEC/Batteries input power wiring terminal labeled 3 and 7 can provide two copper
busbars. Therefore, you can determine the installation position according to different
scenarios.
– 1. When the APM30H and the IBBS200T are stacked, the TEC/battery input power
cable is connected to the top of the power distribution box.
– 2. When the APM30H and the IBBS200T are chained, the TEC/battery input power
cable is connected to the bottom of the power distribution box.
l The CMUA on the inner side of the cabinet door of the IBBS200T collects alarm signals
from the door status sensor, FAN unit, and battery temperature sensor, and then reports the
signals to the PMU on the APM30H side to implement centralized monitoring.

4.3 Cable Connections of the IBBS200T


The cables of the IBBS200T are power cables and signal cables.
Figure 4-3 shows the cable connections of the IBBS200T.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

Figure 4-3 Cable connections of the IBBS200T

(1) Negative power cable for the (2) Power transfer cable for the (3) Negative power cable for the
upper-level batteries TEC cooler lower-level batteries

(4) Input power cable for the (5) Input power cable for the TEC -
batteries cooler

4.4 IBBS200T Components


The components of the IBBS200T consist of the TEC cooler, power distribution box, CMUA,
and batteries.

4.4.1 TEC Cooler


The TEC cooler is installed in the TEC cooler hood on the front door of the cabinet. The TEC
cooler consists of the TEC module, inner air circulation fan, outer air circulation fan, cooling
fin, and monitoring board.
4.4.2 Power Distribution Box
The power distribution box (PDB), which converts and distributes power for the batteries and
TEC cooler or FAN unit, is installed on the right inner side in the upper part of the cabinet.
4.4.3 CMUA
This describes the Central Monitoring Unit type A (CMUA).
4.4.4 Battery
This provides the exterior of batteries and describes technical specifications and types of
batteries.

4-4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

4.4.1 TEC Cooler


The TEC cooler is installed in the TEC cooler hood on the front door of the cabinet. The TEC
cooler consists of the TEC module, inner air circulation fan, outer air circulation fan, cooling
fin, and monitoring board.

Exterior
Figure 4-4 shows the TEC cooler.

Figure 4-4 TEC cooler

Functions
The TEC cooler implements the following functions:
l The TEC cooler obtains -48 V DC power from the EPS of the APM30H.
l When the ambient temperature is 500C without solar radiation and the battery is in the float
charging state, the temperature in the cabinet is not greater than 400C. If the battery is in
the boost charging state, the temperature is not greater than 450C.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-5


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

l When the ambient temperature is 500C with solar radiation of 1120 W/m2 and the battery
is in the float charging state, the temperature in the cabinet is not greater than 450C. If the
battery is in the boost charging state, the temperature is not greater than 500C.
l When the ambient temperature is 320C and there is no temperature difference between the
air inlets at the hot and cold sides of the TEC cooler, the refrigeration power of the TEC
cooler is not less than 190 W (±10%), and the COP is not less than 0.5.

4.4.2 Power Distribution Box


The power distribution box (PDB), which converts and distributes power for the batteries and
TEC cooler or FAN unit, is installed on the right inner side in the upper part of the cabinet.

Exterior
Figure 4-5 shows the PDB.

Figure 4-5 PDB

External Structure
Figure 4-6 shows the external structure of the PDB.

4-6 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

Figure 4-6 External structure of the PDB

(1) RTN(+) cable for the batteries in (2) Input power cable for the (3) Input power cable for the TEC
the upper part batteries cooler or FAN unit

(4) Input power cable for the TEC (5) Input power cable for the (6) Power transfer cable for the TEC
cooler or FAN unit batteries cooler or FAN unit

(7) -48 V cable for the batteries in (8) -48 V cable for the batteries in (9) RTN(+) cable for the batteries in
the lower part the upper part the lower part

NOTE
The input power cables for the batteries and TEC cooler or FAN unit can be connected to the PDB from the top
or bottom in different scenarios. Figure 4-6 shows the cables connected to the PDB from the bottom.

4.4.3 CMUA
This describes the Central Monitoring Unit type A (CMUA).

Functions
The CMUA implements the following functions:

l Automatically adjusts and controls the temperature of the cabinet in different temperature
control modes.
l Reserves three ports for Boolean inputs and detects the Boolean alarms in the cabinet. The
remote detection, however, is not supported.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-7


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

l Provides an RJ-45 port for the ELU and monitors the information about the cabinet type.

Ports
Figure 4-7 shows the ports on the CMUA.

Figure 4-7 Ports on the CMUA

(1) TEM/TEM_BAT port (2) COM_OUT port (3) COM_IN port (4) LEDs

(5) ELU port (6) GATE port (7) IN0 port (8) IN1 port

(9) IN2 port (10) SMOKE port (11) FAN_EXT port (12) PWR port

(13) Port for the TEC cooler (14) FAN1/FAN_EXT port (15) FAN2/FAN_INTT port -

Table 4-1 describes the ports on the CMUA.

Table 4-1 Ports on the CMUA


Port Description

TEM/TEM_BAT port l The port is not used in the APM30H or


TMC11H.
l The silkscreen of the port in the RFC is
TEM. The port is used for connection to
the air inlet temperature sensor.
l The silkscreen of the port in the IBBS200D
or IBBS200T is TEM_BAT. The port is
used for connection to the battery
temperature sensor.

COM_OUT port Used for connecting to the PMU or lower-


level CMUA

COM_IN port Used for connecting to the BBU or upper-


level CMUA

4-8 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

Port Description

LEDs l RUN LED: indicates the running status of


fans.
l ALM LED: indicates the alarm status of
the fans.
Table 4-2 describes the LEDs and their
status.

ELU port Used for reporting the information about the


cabinet type

GATE port Port for the door status sensor

IN0, IN1, and IN2 ports Used for receiving three Boolean inputs

SMOKE port Port for the smoke sensor

FAN_EXT port The port is used only in the APM30H or


TMC11H. It is used for connection to the
outer air circulation fans on the front door of
the cabinet.

PWR port Used for feeding DC input power into the


board

Port for the TEC cooler The port is used only in the IBBS200T. It is
used used for connection to the TEC cooler.

FAN1/FAN_EXT port l The silkscreen of the port in the APM30H


or TMC11H is FAN1. The port is used for
connection to the fans in the fan box.
l The silkscreen of the port in the RFC or
IBBS200D is FAN1. The port is used for
connection to the fans on the right of the
fan box.
l The silkscreen of the port in the IBBS200T
is FAN_EXT. The port is used for
connection to the outer air circulation fans
of the TEC cooler.

FAN2/FAN_INT port l The silkscreen of the port in the RFC or


IBBS200D is FAN2. The port is used for
connection to the fans on the left of the fan
box.
l The silkscreen of the port in the IBBS200T
is FAN_INT. The port is used for
connection to the inner air circulation fans
of the TEC cooler.

LEDs
Table 4-2 describes the LEDs on the CMUA.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-9


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

Table 4-2 LEDs on the CMUA

Label Color Status Description

RUN Green Blinking (ON for 1s and The board is functional, and the
OFF for 1s) communication with the main control unit is
normal.

Blinking (ON for The board is functional, but the


0.125s and OFF for communication with the main control unit
0.125s) fails. (If the board does not communicate with
the main control unit for one minute, the
communication fails.)

ON or OFF The board is faulty (it is not in the power-on


self check state).

ALM Red OFF No alarm is generated.

ON An alarm is generated, and the board needs to


be replaced.

Blinking (ON for 1s and An alarm is generated, and the alarm may be
OFF for 1s) caused by the faults of the related boards or
ports. Therefore, whether the board needs to
be replaced cannot be determined.

DIP Switches
Three DIP switches are displayed on the CMUA panel, indicating the working modes of the
CMUA in different cabinets. Figure 4-8 shows the DIP switches on the CMUA.

Figure 4-8 DIP switches on the CMUA

Figure 4-9 shows the bit settings of the CMUA in different cabinets.

4-10 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

Figure 4-9 Bit settings of the CMUA in different cabinets

NOTE

The red rectangle in Figure 4-9 shows the position for connecting to the jumper cap.

4.4.4 Battery
This provides the exterior of batteries and describes technical specifications and types of
batteries.

NOTE
The exterior and technical specifications of the battery may vary according to manufacturer. The following
description is based on common batteries.

Exterior
Figure 4-10 shows the battery.

Figure 4-10 Battery

(1) A 12 V 50 Ah battery (2) A 12 V 92 Ah battery

Technical Specifications
Table 4-3 describes the technical specifications of the battery.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-11


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

Table 4-3 Technical specifications of the battery

Type Dimensions (Width x Weight


Height x Depth)

12 V 50 Ah 105 mm x 227 mm x 390 mm 21.5 kg

12 V 92 Ah 105 mm x 287 mm x 390 mm 33.5 kg

108 mm x 287 mm x 393 mm 35 kg

Configuration
The cabinet supports four types of battery packs: 48 V 50 Ah, 48 V 100 Ah, 48 V 92 Ah, and
48 V 184 Ah.

l The upper and lower 48 V 50 Ah battery packs can be connected in parallel to provide 48
V 100 Ah power.
l The upper and lower 48 V 92 Ah battery packs can be connected in parallel to provide 48
V 184 Ah power.
l Each battery pack contains four single batteries.

4.5 IBBS200T Cables


The IBBS200T cables consist of the equipotential cable, input power cables for the batteries,
power cable for the TEC cooler, and monitoring signal cable.

4.5.1 PGND Cable


The PGND cables consist of the PGND cable for the cabinet and PGND cables for the modules
in the cabinet.
4.5.2 Equipotential Cable
The equipotential cable connects the PGND terminals of the cabinets, ensuring the equipotential
connection and safe running of the base station.
4.5.3 Power Cables for the Batteries
This describes the input power cables for the batteries, power cables between the batteries and
the copper bar in the junction box, and Inter-battery connection copper bar.
4.5.4 Power Cables for the TEC Cooler
The power cables for the TEC cooler consist of the input power cable for the TEC cooler and
the power transfer cable for the TEC cooler.
4.5.5 Monitoring Signal Cable for the Battery Cabinet
The monitoring signal cable collects and transmits the monitoring signals of the IBBS200D or
IBBS200T to the PMU.

4.5.1 PGND Cable


The PGND cables consist of the PGND cable for the cabinet and PGND cables for the modules
in the cabinet.

4-12 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

Exterior
All PGND cables have the same exterior. Both ends of the cables are linked with OT terminals.
Figure 4-11 and Figure 4-12 show the PGND cables.

Figure 4-11 PGND cable for the cabinet

OT terminal

Figure 4-12 PGND cable for the modules

OT terminal

Cable Description
Table 4-4 describes the PGND cables.

Table 4-4 PGND cables

Cable Color Cross-Sectional Area

PGND cable for the cabinet Green and yellow 16 mm2

PGND cable for the modules Green and yellow 6 mm2


in the cabinet

4.5.2 Equipotential Cable


The equipotential cable connects the PGND terminals of the cabinets, ensuring the equipotential
connection and safe running of the base station.

Exterior
Figure 4-13 shows the equipotential cable.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-13


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

Figure 4-13 Equipotential cable

Cable Description
Table 4-5 describes the equipotential cable.

Table 4-5 Equipotential cable


Cable Color Cross-Sectional Area

Equipotential cable Green and yellow 16 mm2

4.5.3 Power Cables for the Batteries


This describes the input power cables for the batteries, power cables between the batteries and
the copper bar in the junction box, and Inter-battery connection copper bar.

Structure
Figure 4-14 shows the input power cables for the batteries.

Figure 4-14 Input power cables for the batteries

(1) Power series 120 connector (2) OT terminal (16mm2, M6)

Figure 4-15 shows the power cable between the batteries and the copper bar in the junction box.

4-14 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

Figure 4-15 Power cable between the batteries and the copper bar in the junction box

(1) OT terminal (16mm2, M6)

The inter-battery connection copper bar between batteries is delivered with the batteries. Figure
4-16 shows the inter-battery connection copper bar.

Figure 4-16 Inter-battery connection copper bar

Specifications
l Of the input power cables for the batteries, the RTN(+) cable is red, with a cross-sectional
area of 16 mm2, and the NEG(-) cable is black, with a cross-sectional area of 16 mm2.
l Of the power cables between the batteries and the copper bar in the junction box, the RTN
(+) cable is red, with a cross-sectional area of 16 mm2, and the NEG(-) cable is black, with
a cross-sectional area of 16 mm2.

4.5.4 Power Cables for the TEC Cooler


The power cables for the TEC cooler consist of the input power cable for the TEC cooler and
the power transfer cable for the TEC cooler.

Structure
Figure 4-17 shows the input power cable for the TEC cooler.

Figure 4-17 Input power cable for the TEC cooler

(1) Easy power receptacle (pressfit type) connector (2) OT terminal (2.5mm2, M4)

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-15


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
4 Overview of the IBBS200T User Guide

Figure 4-18 shows the power transfer cable for the TEC cooler.

Figure 4-18 Power transfer cable for the TEC cooler

(1) 3V3 power connector (2) OT terminal (1.5mm2, (3) OT terminal (6mm2, (4) OT terminal (1.5mm2,
M6) M4) M4)

4.5.5 Monitoring Signal Cable for the Battery Cabinet


The monitoring signal cable collects and transmits the monitoring signals of the IBBS200D or
IBBS200T to the PMU.

Structure
Figure 4-19 shows the monitoring signal cable for the battery cabinet.

Figure 4-19 Monitoring signal cable for the battery cabinet

(1) RJ-45 connector

Pin Assignment
Table 4-6 describes the pin assignment for the wires of the monitoring signal cable for the battery
cabinet.

Table 4-6 Pin assignment for the wires of the monitoring signal cable for the battery cabinet

X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

4-16 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 4 Overview of the IBBS200T

X1 End X2 End Wire Color Type

X1.6 X2.6 Green

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 4-17


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

5 Overview of the IBBS200D

About This Chapter

This describes the exterior, structure, components, and cables of the IBBS200D.

5.1 Exterior of the IBBS200D


The IBBS200D is brightly colored and elegantly designed. It is small in size and easy to transport.
5.2 Structure of the IBBS200D
The IBBS200D has a highly integrated and modular structure design. The power distribution
box (PDB) of the IBBS200T is installed to the upper right inside the cabinet, and the CMUA is
installed on the inner side of the cabinet door.
5.3 Cable Connections of the IBBS200D
The cables of the IBBS200D are power cables and signal cables.
5.4 IBBS200D Components
The components of the IBBS200D consist of the fans, fan box, CMUA, power distribution box,
batteries, and heating film. The heating film is optional.
5.5 IBBS200D Cables
The IBBS200D cables consist of the equipotential cable, input power cables for the batteries,
power cable for the fans, input power cable for the heating film, and monitoring signal cable.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

5.1 Exterior of the IBBS200D


The IBBS200D is brightly colored and elegantly designed. It is small in size and easy to transport.
Figure 5-1 shows exterior of the IBBS200D.

Figure 5-1 Exterior of the IBBS200D

5.2 Structure of the IBBS200D


The IBBS200D has a highly integrated and modular structure design. The power distribution
box (PDB) of the IBBS200T is installed to the upper right inside the cabinet, and the CMUA is
installed on the inner side of the cabinet door.
Figure 5-2 shows the internal structure of the IBBS200D

5-2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

Figure 5-2 Internal structure of the IBBS200D

(1) FAN unit (2) CMUA (3) ELU (4) Input power (5) FAN/Battery input
transfer terminal for power wiring
the heating film terminals

(6) MCBs of the (7) MCB of the (8) MCB of the (9) FAN/Battery input -
TEC/FAN batteries in the lower batteries in the upper power wiring
part part terminals

Structure of the cabinet:

l Each FAN/battery input power wiring terminal numbered 5 and 9 can provide two copper
busbars. Therefore, you can determine the installation position according to different
scenarios.
– 1. When the APM30H and the IBBS200D are stacked, the FAN/Batteries input power
cable is connected to the top of the power distribution box.
– 2. When the APM30H and the IBBS200D are chained, the FAN/battery input power
cable is connected to the bottom of the power distribution box.
l The CMUA on the inner side of the cabinet door of the IBBS200D collects alarm signals
from the door status sensor, FAN, and temperature sensor of the batteries, and then reports
them to the PMU on the APM30H side to achieve the central monitoring.

5.3 Cable Connections of the IBBS200D


The cables of the IBBS200D are power cables and signal cables.

Figure 5-3 shows the cable connections of the IBBS200D.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

Figure 5-3 Cable connections of the IBBS200D

(1) 5.5.3 Power Cables for the (2) 5.5.4 Power Cables for the Fans (3) Power cable for the heating film
Batteries in the IBBS200D

(4) 5.5.5 Power Cable for the (5) 5.5.3 Power Cables for the (6) 5.5.3 Power Cables for the
Heating Film Batteries Batteries

(7) 5.5.4 Power Cables for the Fans - -


in the IBBS200D

5.4 IBBS200D Components


The components of the IBBS200D consist of the fans, fan box, CMUA, power distribution box,
batteries, and heating film. The heating film is optional.

5.4.1 Fan Box


The fan box is installed on the front door of the cabinet and houses the fans and CMUA.
5.4.2 Power Distribution Box
The power distribution box (PDB), which converts and distributes power for the batteries and
TEC cooler or FAN unit, is installed on the right inner side in the upper part of the cabinet.
5.4.3 CMUA
This describes the Central Monitoring Unit type A (CMUA).
5.4.4 Battery
This provides the exterior of batteries and describes technical specifications and types of
batteries.
5.4.5 Heating Film

5-4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

This describes the exterior, functions, and technical specifications of the heating film. The
heating film is optional.

5.4.1 Fan Box


The fan box is installed on the front door of the cabinet and houses the fans and CMUA.

Exterior
Figure 5-4 shows the fan box.

Figure 5-4 Fan box

Functions
The fan box implements the following functions:

l The fans speed up the circulation of the air inside and outside the cabinet and keep the
temperature in the cabinet in a normal range, ensuring optimum performance of the
batteries.
l The CMUA collects the alarm signals from the components such as the door status sensor,
temperature sensor of the battery, fan, and smoke sensor. Then, the monitoring unit
transmits the alarm signals to the PMU through the RS485 signals.

5.4.2 Power Distribution Box


The power distribution box (PDB), which converts and distributes power for the batteries and
TEC cooler or FAN unit, is installed on the right inner side in the upper part of the cabinet.

Exterior
Figure 5-5 shows the PDB.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-5


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

Figure 5-5 PDB

External Structure
Figure 5-6 shows the external structure of the PDB.

5-6 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

Figure 5-6 External structure of the PDB

(1) RTN(+) cable for the batteries in (2) Input power cable for the (3) Input power cable for the TEC
the upper part batteries cooler or FAN unit

(4) Input power cable for the TEC (5) Input power cable for the (6) Power transfer cable for the TEC
cooler or FAN unit batteries cooler or FAN unit

(7) -48 V cable for the batteries in (8) -48 V cable for the batteries in (9) RTN(+) cable for the batteries in
the lower part the upper part the lower part

NOTE
The input power cables for the batteries and TEC cooler or FAN unit can be connected to the PDB from the top
or bottom in different scenarios. Figure 5-6 shows the cables connected to the PDB from the bottom.

5.4.3 CMUA
This describes the Central Monitoring Unit type A (CMUA).

Functions
The CMUA implements the following functions:

l Automatically adjusts and controls the temperature of the cabinet in different temperature
control modes.
l Reserves three ports for Boolean inputs and detects the Boolean alarms in the cabinet. The
remote detection, however, is not supported.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-7


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

l Provides an RJ-45 port for the ELU and monitors the information about the cabinet type.

Ports
Figure 5-7 shows the ports on the CMUA.

Figure 5-7 Ports on the CMUA

(1) TEM/TEM_BAT port (2) COM_OUT port (3) COM_IN port (4) LEDs

(5) ELU port (6) GATE port (7) IN0 port (8) IN1 port

(9) IN2 port (10) SMOKE port (11) FAN_EXT port (12) PWR port

(13) Port for the TEC cooler (14) FAN1/FAN_EXT port (15) FAN2/FAN_INTT port -

Table 5-1 describes the ports on the CMUA.

Table 5-1 Ports on the CMUA


Port Description

TEM/TEM_BAT port l The port is not used in the APM30H or


TMC11H.
l The silkscreen of the port in the RFC is
TEM. The port is used for connection to
the air inlet temperature sensor.
l The silkscreen of the port in the IBBS200D
or IBBS200T is TEM_BAT. The port is
used for connection to the battery
temperature sensor.

COM_OUT port Used for connecting to the PMU or lower-


level CMUA

COM_IN port Used for connecting to the BBU or upper-


level CMUA

5-8 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

Port Description

LEDs l RUN LED: indicates the running status of


fans.
l ALM LED: indicates the alarm status of
the fans.
Table 5-2 describes the LEDs and their
status.

ELU port Used for reporting the information about the


cabinet type

GATE port Port for the door status sensor

IN0, IN1, and IN2 ports Used for receiving three Boolean inputs

SMOKE port Port for the smoke sensor

FAN_EXT port The port is used only in the APM30H or


TMC11H. It is used for connection to the
outer air circulation fans on the front door of
the cabinet.

PWR port Used for feeding DC input power into the


board

Port for the TEC cooler The port is used only in the IBBS200T. It is
used used for connection to the TEC cooler.

FAN1/FAN_EXT port l The silkscreen of the port in the APM30H


or TMC11H is FAN1. The port is used for
connection to the fans in the fan box.
l The silkscreen of the port in the RFC or
IBBS200D is FAN1. The port is used for
connection to the fans on the right of the
fan box.
l The silkscreen of the port in the IBBS200T
is FAN_EXT. The port is used for
connection to the outer air circulation fans
of the TEC cooler.

FAN2/FAN_INT port l The silkscreen of the port in the RFC or


IBBS200D is FAN2. The port is used for
connection to the fans on the left of the fan
box.
l The silkscreen of the port in the IBBS200T
is FAN_INT. The port is used for
connection to the inner air circulation fans
of the TEC cooler.

LEDs
Table 5-2 describes the LEDs on the CMUA.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-9


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

Table 5-2 LEDs on the CMUA

Label Color Status Description

RUN Green Blinking (ON for 1s and The board is functional, and the
OFF for 1s) communication with the main control unit is
normal.

Blinking (ON for The board is functional, but the


0.125s and OFF for communication with the main control unit
0.125s) fails. (If the board does not communicate with
the main control unit for one minute, the
communication fails.)

ON or OFF The board is faulty (it is not in the power-on


self check state).

ALM Red OFF No alarm is generated.

ON An alarm is generated, and the board needs to


be replaced.

Blinking (ON for 1s and An alarm is generated, and the alarm may be
OFF for 1s) caused by the faults of the related boards or
ports. Therefore, whether the board needs to
be replaced cannot be determined.

DIP Switches
Three DIP switches are displayed on the CMUA panel, indicating the working modes of the
CMUA in different cabinets. Figure 5-8 shows the DIP switches on the CMUA.

Figure 5-8 DIP switches on the CMUA

Figure 5-9 shows the bit settings of the CMUA in different cabinets.

5-10 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

Figure 5-9 Bit settings of the CMUA in different cabinets

NOTE

The red rectangle in Figure 5-9 shows the position for connecting to the jumper cap.

5.4.4 Battery
This provides the exterior of batteries and describes technical specifications and types of
batteries.

NOTE
The exterior and technical specifications of the battery may vary according to manufacturer. The following
description is based on common batteries.

Exterior
Figure 5-10 shows the battery.

Figure 5-10 Battery

(1) A 12 V 50 Ah battery (2) A 12 V 92 Ah battery

Technical Specifications
Table 5-3 describes the technical specifications of the battery.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-11


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

Table 5-3 Technical specifications of the battery


Type Dimensions (Width x Weight
Height x Depth)

12 V 50 Ah 105 mm x 227 mm x 390 mm 21.5 kg

12 V 92 Ah 105 mm x 287 mm x 390 mm 33.5 kg

108 mm x 287 mm x 393 mm 35 kg

Configuration
The cabinet supports four types of battery packs: 48 V 50 Ah, 48 V 100 Ah, 48 V 92 Ah, and
48 V 184 Ah.
l The upper and lower 48 V 50 Ah battery packs can be connected in parallel to provide 48
V 100 Ah power.
l The upper and lower 48 V 92 Ah battery packs can be connected in parallel to provide 48
V 184 Ah power.
l Each battery pack contains four single batteries.

5.4.5 Heating Film


This describes the exterior, functions, and technical specifications of the heating film. The
heating film is optional.
NOTE
The IBBS200D has two heating films, which are installed on the upper and lower baffle plates.

Exterior
Figure 5-11 shows the heating film.

Figure 5-11 Heating film

5-12 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

Functions
The heating film ensures that the batteries are stored and function at the proper temperature when
the ambient temperature is low. When the ambient temperature is lower than the normal working
temperature of the battery, the battery capacity decreases. In this case, the heating film is required
to guarantee the best performance of the batteries.

Technical Specifications
The technical specifications of the heating film are as follows:

l The heating film works with the rated voltage of 220 V AC, and the rated heating power
is 100 W.
l When the ambient temperature is lower than 00C, the heating film starts working; when the
ambient temperature is higher than 150C, the heating film stops working.
l The surface of the heating film can tolerate a temperature from -400C to +2500C.

5.5 IBBS200D Cables


The IBBS200D cables consist of the equipotential cable, input power cables for the batteries,
power cable for the fans, input power cable for the heating film, and monitoring signal cable.

5.5.1 PGND Cable


The PGND cables consist of the PGND cable for the cabinet and PGND cables for the modules
in the cabinet.
5.5.2 Equipotential Cable
The equipotential cable connects the PGND terminals of the cabinets, ensuring the equipotential
connection and safe running of the base station.
5.5.3 Power Cables for the Batteries
This describes the input power cables for the batteries, power cables between the batteries and
the copper bar in the junction box, and Inter-battery connection copper bar.
5.5.4 Power Cables for the Fans in the IBBS200D
The power cables for the fans in the IBBS200D consist of the input power cable for the fans in
the IBBS200D and the power transfer cable for the fans in the IBBS200D.
5.5.5 Power Cable for the Heating Film
The power cable connects the output terminal on the junction box on the left of the AMP30H
cabinet to the AC power input terminal on the heating film.
5.5.6 Monitoring Signal Cable for the Battery Cabinet
The monitoring signal cable collects and transmits the monitoring signals of the IBBS200D or
IBBS200T to the PMU.

5.5.1 PGND Cable


The PGND cables consist of the PGND cable for the cabinet and PGND cables for the modules
in the cabinet.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-13


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

Exterior
All PGND cables have the same exterior. Both ends of the cables are linked with OT terminals.
Figure 5-12 and Figure 5-13 show the PGND cables.

Figure 5-12 PGND cable for the cabinet

OT terminal

Figure 5-13 PGND cable for the modules

OT terminal

Cable Description
Table 5-4 describes the PGND cables.

Table 5-4 PGND cables

Cable Color Cross-Sectional Area

PGND cable for the cabinet Green and yellow 16 mm2

PGND cable for the modules Green and yellow 6 mm2


in the cabinet

5.5.2 Equipotential Cable


The equipotential cable connects the PGND terminals of the cabinets, ensuring the equipotential
connection and safe running of the base station.

Exterior
Figure 5-14 shows the equipotential cable.

5-14 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

Figure 5-14 Equipotential cable

Cable Description
Table 5-5 describes the equipotential cable.

Table 5-5 Equipotential cable


Cable Color Cross-Sectional Area

Equipotential cable Green and yellow 16 mm2

5.5.3 Power Cables for the Batteries


This describes the input power cables for the batteries, power cables between the batteries and
the copper bar in the junction box, and Inter-battery connection copper bar.

Structure
Figure 5-15 shows the input power cables for the batteries.

Figure 5-15 Input power cables for the batteries

(1) Power series 120 connector (2) OT terminal (16mm2, M6)

Figure 5-16 shows the power cable between the batteries and the copper bar in the junction box.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-15


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

Figure 5-16 Power cable between the batteries and the copper bar in the junction box

(1) OT terminal (16mm2, M6)

The inter-battery connection copper bar between batteries is delivered with the batteries. Figure
5-17 shows the inter-battery connection copper bar.

Figure 5-17 Inter-battery connection copper bar

Specifications
l Of the input power cables for the batteries, the RTN(+) cable is red, with a cross-sectional
area of 16 mm2, and the NEG(-) cable is black, with a cross-sectional area of 16 mm2.
l Of the power cables between the batteries and the copper bar in the junction box, the RTN
(+) cable is red, with a cross-sectional area of 16 mm2, and the NEG(-) cable is black, with
a cross-sectional area of 16 mm2.

5.5.4 Power Cables for the Fans in the IBBS200D


The power cables for the fans in the IBBS200D consist of the input power cable for the fans in
the IBBS200D and the power transfer cable for the fans in the IBBS200D.

Structure
Figure 5-18 shows the input power cable for the fans in the IBBS200D.

Figure 5-18 Input power cable for the fans in the IBBS200D

(1) Easy power receptacle (pressfit type) connector (2) OT terminal (2.5mm2, M4)

5-16 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 5 Overview of the IBBS200D

Figure 5-19 shows the power transfer cable for the fans in the IBBS200D.

Figure 5-19 Power transfer cable for the fans in the IBBS200D

(1) 3V3 power connector (2) OT terminal (1.5mm2, (3) OT terminal (6mm2, (4) OT terminal (1.5mm2,
M6) M4) M4)

5.5.5 Power Cable for the Heating Film


The power cable connects the output terminal on the junction box on the left of the AMP30H
cabinet to the AC power input terminal on the heating film.

Structure
Figure 5-20 shows the power cable for the heating film.

Figure 5-20 Power cable for the heating film

(1) OT terminal (1.5mm2, M4) for the APM30H cabinet (2) OT terminal (1.5mm2, M4) for the battery cabinet

Specifications
The AC power cable for the heating film has a cross-sectional area of 1.5 mm2 with a black
jacket. The cable consists of the blue and brown wires.

5.5.6 Monitoring Signal Cable for the Battery Cabinet


The monitoring signal cable collects and transmits the monitoring signals of the IBBS200D or
IBBS200T to the PMU.

Structure
Figure 5-21 shows the monitoring signal cable for the battery cabinet.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 5-17


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
5 Overview of the IBBS200D User Guide

Figure 5-21 Monitoring signal cable for the battery cabinet

(1) RJ-45 connector

Pin Assignment
Table 5-6 describes the pin assignment for the wires of the monitoring signal cable for the battery
cabinet.

Table 5-6 Pin assignment for the wires of the monitoring signal cable for the battery cabinet
X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

5-18 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

6 Overview of the TMC11H

About This Chapter

This describes the exterior, structure, components, and cables of the TMC11H.

6.1 Exterior of the TMC11H


The TMC11H is brightly colored and elegantly designed. It is small in size and easy to transport.
6.2 Structure of the TMC11H
The TMC11H has a highly integrated and modular structure design. Thus, the cabinet is easy to
operate and maintain.
6.3 Cable Connections of the TMC11H
The cables of the TMC11H are power cables and signal cables.
6.4 TMC11H Components
The components of the TMC11H consist of the fan box, DCDU-03, and heater. The heater is
optional.
6.5 TMC11H Cables
The TMC11H cables consist of the equipotential cable, input power cable, power cable for the
fan box, ELU signal cable, signal cables between the CMUA and the door status sensor, and
transfer cable for the fan on the front door.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

6.1 Exterior of the TMC11H


The TMC11H is brightly colored and elegantly designed. It is small in size and easy to transport.
Figure 6-1 shows the TMC11H.

Figure 6-1 TMC11H

6.2 Structure of the TMC11H


The TMC11H has a highly integrated and modular structure design. Thus, the cabinet is easy to
operate and maintain.
Figure 6-2 shows the internal structure of the TMC11H.

6-2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

Figure 6-2 Internal structure of the TMC11H

(1) Inner air circulation fan (2) CMUA (3) DCDU-03

(4) ELU (5) Door status sensor (6) Outer air circulation fan

(7) Heat exchanger (8) Junction box -

The TMC11H has the following features with regard to its structure:
l If the heater is not installed, the TMC11H provides a 11 U space for user equipment.
l The heater should be installed in the 1 U space at the bottom of the TMC11H.
l The TMC11H provides a 1 U space at the top for operation and maintenance of the fan box.

6.3 Cable Connections of the TMC11H


The cables of the TMC11H are power cables and signal cables.
Figure 6-3 shows the cable connection of the TMC11H.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

Figure 6-3 Cable connections of the TMC11H

(1) Power transfer cable for the (2) 6.5.2 Input Power Cable for the (3) 6.5.5 Door Status Monitoring
heater TMC11H Cable

(4) 6.5.4 ELU Signal Cable (5) 6.5.3 Power Cable for the Fan -
Box in the TMC11H

6.4 TMC11H Components


The components of the TMC11H consist of the fan box, DCDU-03, and heater. The heater is
optional.

6.4.1 Fan Box


The fan box consists of the fan subrack, fans, HPMI, and CMUA.
6.4.2 DCDU-03
The Direct Current Distribution Unit-03 (DCDU-03) supplies DC power to each component in
the cabinet. The height of the DCDU-03 is 1 U. It can be classified into the DCDU-03B and
DCDU-03C according to the configured MCBs and application scenarios. The two models have
the same exterior, engineering specifications, and ports.
6.4.3 Heater
The heater provides the proper operating temperature for the customer equipment working in
low temperature in the cabinet. The heater is optional.

6.4.1 Fan Box


The fan box consists of the fan subrack, fans, HPMI, and CMUA.

6-4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

Figure 6-4 shows the fan box.

Figure 6-4 Fan Box

(1) Fans (2) Fan subrack (3) CMUA (4) HPMI

Fans
Fans are installed in the fan box of the cabinet. They dissipate the heat for the cabinet.

Exterior
Figure 6-5 shows a fan.

Figure 6-5 Fan

Technical Specifications
Table 6-1 describes the technical specifications of the fan.

Table 6-1 Technical specifications of the fan

Item Specification

Dimensions (Diameter x Height) 175 mm x 69 mm

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-5


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

Item Specification

Length of the lead 450 mm


NOTE
The lead is delivered with the fan and is used for
power input and monitoring.

Definition of pins 1 to 4 of the lead l Pin 1: red, connected to the positive pole
of the power supply
l Pin 2: yellow, connected to the input of the
speed-adjusting signals
l Pin 3: blue, connected to the output of the
alarm or speed signals
l Pin 4: black, connected to the negative pole
of the power supply
NOTE
The colors of the cables of the fans vary according
to the manufacturer.

Rated voltage -48 V

Operating voltage range -36 V to -57 V

Rated current 0.52 A

Maximum current 0.77 A

Rated power 24.96 W

Maximum power 36.96 W

Rated speed 3100 r/min

Speed-adjusting mode PWM mode

HPMI
The Hert Power Monitoring Interface unit (HPMI) transfers the power monitoring signals and
provides ports for the input and output of various alarm signals.

Exterior
Figure 6-6 shows the HPMI.

Figure 6-6 HPMI

6-6 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

Ports
Figure 6-7 shows the ports on the panel of the HPMI, and Table 6-2 describes the ports on the
panel of the HPMI.

Figure 6-7 Ports on the panel of the HPMI

- + - + - + - + - + - + - + - +
PMU_DB50 OUT0 OUT1 IN0 IN1 IN2 FUSE GATE TEM_BAT1 IN3 IN4 SMOKE WATER TEM_HUM

Table 6-2 Ports on the panel of the HPMI


Port Function

PMU_DB50 Transferring the monitoring signals of the


PMU

OUT0, OUT1 Transmitting two Boolean outputs

IN0, IN1, and IN2 Receiving three Boolean inputs

FUSE Detecting the fuse alarm signals

GATE Receiving the door status alarm input signals

IN3, IN4 Receiving two Boolean inputs

TEM_BAT1 Receiving the battery temperature monitoring


input

SMOKE Receiving the smoke alarm input

WATER Receiving the water damage alarm input

TEM_HUM Receiving the temperature and humidity


alarm input

CMUA
This describes the Central Monitoring Unit type A (CMUA).

Functions
The CMUA implements the following functions:
l Automatically adjusts and controls the temperature of the cabinet in different temperature
control modes.
l Reserves three ports for Boolean inputs and detects the Boolean alarms in the cabinet. The
remote detection, however, is not supported.
l Provides an RJ-45 port for the ELU and monitors the information about the cabinet type.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-7


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

Ports
Figure 6-8 shows the ports on the CMUA.

Figure 6-8 Ports on the CMUA

(1) TEM/TEM_BAT port (2) COM_OUT port (3) COM_IN port (4) LEDs

(5) ELU port (6) GATE port (7) IN0 port (8) IN1 port

(9) IN2 port (10) SMOKE port (11) FAN_EXT port (12) PWR port

(13) Port for the TEC cooler (14) FAN1/FAN_EXT port (15) FAN2/FAN_INTT port -

Table 6-3 describes the ports on the CMUA.

Table 6-3 Ports on the CMUA


Port Description

TEM/TEM_BAT port l The port is not used in the APM30H or


TMC11H.
l The silkscreen of the port in the RFC is
TEM. The port is used for connection to
the air inlet temperature sensor.
l The silkscreen of the port in the IBBS200D
or IBBS200T is TEM_BAT. The port is
used for connection to the battery
temperature sensor.

COM_OUT port Used for connecting to the PMU or lower-


level CMUA

COM_IN port Used for connecting to the BBU or upper-


level CMUA

6-8 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

Port Description

LEDs l RUN LED: indicates the running status of


fans.
l ALM LED: indicates the alarm status of
the fans.
Table 6-4 describes the LEDs and their
status.

ELU port Used for reporting the information about the


cabinet type

GATE port Port for the door status sensor

IN0, IN1, and IN2 ports Used for receiving three Boolean inputs

SMOKE port Port for the smoke sensor

FAN_EXT port The port is used only in the APM30H or


TMC11H. It is used for connection to the
outer air circulation fans on the front door of
the cabinet.

PWR port Used for feeding DC input power into the


board

Port for the TEC cooler The port is used only in the IBBS200T. It is
used used for connection to the TEC cooler.

FAN1/FAN_EXT port l The silkscreen of the port in the APM30H


or TMC11H is FAN1. The port is used for
connection to the fans in the fan box.
l The silkscreen of the port in the RFC or
IBBS200D is FAN1. The port is used for
connection to the fans on the right of the
fan box.
l The silkscreen of the port in the IBBS200T
is FAN_EXT. The port is used for
connection to the outer air circulation fans
of the TEC cooler.

FAN2/FAN_INT port l The silkscreen of the port in the RFC or


IBBS200D is FAN2. The port is used for
connection to the fans on the left of the fan
box.
l The silkscreen of the port in the IBBS200T
is FAN_INT. The port is used for
connection to the inner air circulation fans
of the TEC cooler.

LEDs
Table 6-4 describes the LEDs on the CMUA.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-9


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

Table 6-4 LEDs on the CMUA

Label Color Status Description

RUN Green Blinking (ON for 1s and The board is functional, and the
OFF for 1s) communication with the main control unit is
normal.

Blinking (ON for The board is functional, but the


0.125s and OFF for communication with the main control unit
0.125s) fails. (If the board does not communicate with
the main control unit for one minute, the
communication fails.)

ON or OFF The board is faulty (it is not in the power-on


self check state).

ALM Red OFF No alarm is generated.

ON An alarm is generated, and the board needs to


be replaced.

Blinking (ON for 1s and An alarm is generated, and the alarm may be
OFF for 1s) caused by the faults of the related boards or
ports. Therefore, whether the board needs to
be replaced cannot be determined.

DIP Switches
Three DIP switches are displayed on the CMUA panel, indicating the working modes of the
CMUA in different cabinets. Figure 6-9 shows the DIP switches on the CMUA.

Figure 6-9 DIP switches on the CMUA

Figure 6-10 shows the bit settings of the CMUA in different cabinets.

6-10 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

Figure 6-10 Bit settings of the CMUA in different cabinets

NOTE

The red rectangle in Figure 6-10 shows the position for connecting to the jumper cap.

6.4.2 DCDU-03
The Direct Current Distribution Unit-03 (DCDU-03) supplies DC power to each component in
the cabinet. The height of the DCDU-03 is 1 U. It can be classified into the DCDU-03B and
DCDU-03C according to the configured MCBs and application scenarios. The two models have
the same exterior, engineering specifications, and ports.

Exterior
Figure 6-11 shows the DCDU-03.

Figure 6-11 DCDU-03

Functions
The DCDU-03 provides nine -48 V DC outputs and different MCB configurations to meet the
power distribution requirements of the scenarios of distributed and separated base stations.

Table 6-5 describes the DC power distribution functions of the DCDU-03.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-11


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

Table 6-5 DC power distribution functions of the DCDU-03

DCDU DC Output Power MCB MCB Applicatio


Model Terminal Consumpti Specificati Quantity n Scenario
on on
Equipment

DCDU-03B LOAD0 to RRU 20 A 6 Distributed


LOAD5 base station/
Mini base
LOAD6 to BBU and the 12 A 3 station
LOAD8 transmission
equipment of
the customer

DCDU-03C LOAD0 to RRU 12 A 6 Separated


LOAD5 macro base
station
LOAD6 BBU 12 A 1

LOAD7 and Transmissio 6A 2


LOAD8 n equipment
of the
customer

Ports
Figure 6-12 describes the ports on the panel of the DCDU-03.

Figure 6-12 Ports on the panel of the DCDU-03


SW0 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8

LOAD0 LOAD1 LOAD2 LOAD3 LOAD4 LOAD5 LOAD6 LOAD7 LOAD8


SW0 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 DCDU-03C
SPDALM

Table 6-6 describes the ports on the panel of the DCDU-03.

6-12 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

Table 6-6 Ports on the panel of the DCDU-03

Port Specification Cross-Sectional Area Remarks


(Unit: mm2)

DC input Supporting M6 l DCDU-03B: 25 -


terminal 2-hole OT l DCDU-03C: 25
terminal

DC output LOAD0 to 2.5 l Three rows of wiring


terminal LOAD8 (from terminals for outputs:
left to right) NEG(-), RTN(+), and
LOAD0 to PGND, where, the last
LOAD8 three pairs of the PGND
wiring terminals support
the grounding of the M4
2-hole OT terminals,
which are marked in red
in Figure 6-12
l Supporting the output
power cable with a
maximum cross-sectional
area of 6 mm2

6.4.3 Heater
The heater provides the proper operating temperature for the customer equipment working in
low temperature in the cabinet. The heater is optional.

Exterior
The heater is 1 U high. Figure 6-13 shows the heater.

Figure 6-13 Heater

Technical Specifications
The technical specifications of the heater are as follows:

l When the temperature in the cabinet is lower than 00C, the heater starts working; when the
temperature is higher than 150C, the heater stops working.
l The maximum heating power of the heater is 300 W.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-13


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

6.5 TMC11H Cables


The TMC11H cables consist of the equipotential cable, input power cable, power cable for the
fan box, ELU signal cable, signal cables between the CMUA and the door status sensor, and
transfer cable for the fan on the front door.

6.5.1 Equipotential Cable


The equipotential cable connects the PGND terminals of the cabinets, ensuring the equipotential
connection and safe running of the base station.
6.5.2 Input Power Cable for the TMC11H
The input power cable for the TMC11H varies according to the input power mode.
6.5.3 Power Cable for the Fan Box in the TMC11H
The power cable feeds -48 V DC power cable into the fan box in the transmission cabinet from
the DCDU-03.
6.5.4 ELU Signal Cable
The ELU (Electronic Label Unit) signal cable transmits to the CMUA the information about the
cabinet type reported by the ELU.
6.5.5 Door Status Monitoring Cable
The signal cables transmit the information about the opening and closing of the door to the
CMUA from the door status sensor of the RFC, IBBS200D, or IBBS200T.
6.5.6 Transfer Cable for the Fan on the Front Door
The transfer cable feeds power into the fan on the front door of the APM30H or TMC11H and
transmits fan monitoring signals to the CMUA.

6.5.1 Equipotential Cable


The equipotential cable connects the PGND terminals of the cabinets, ensuring the equipotential
connection and safe running of the base station.

Exterior
Figure 6-14 shows the equipotential cable.

Figure 6-14 Equipotential cable

Cable Description
Table 6-7 describes the equipotential cable.

6-14 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

Table 6-7 Equipotential cable

Cable Color Cross-Sectional Area

Equipotential cable Green and yellow 16 mm2

6.5.2 Input Power Cable for the TMC11H


The input power cable for the TMC11H varies according to the input power mode.

Input power cable for the TMC11H (1)


Figure 6-15 shows the TMC11H input power cable in the AC power supply scenario. The
APM30H supplies power to the TMC11H.

Figure 6-15 Input power cable for the TMC11H (1)

(1) Easy power receptacle (pressfit type) connector (2) OT terminal (4mm2, M6)

Input power cable for the TMC11H (2)


Figure 6-16 shows the TMC11H input power cable in the -48 V DC power supply scenario. The
APM30H supplies power to the TMC11H.

Figure 6-16 Input power cable for the TMC11H (2)

(1) OT terminal (2) Parallel terminal

6.5.3 Power Cable for the Fan Box in the TMC11H


The power cable feeds -48 V DC power cable into the fan box in the transmission cabinet from
the DCDU-03.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-15


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

Structure
Figure 6-17 shows the power cable for the fan box in the TMC11H.

Figure 6-17 Power cable for the fan box in the TMC11H

(1) 3V3 power connector (2) OT terminal

6.5.4 ELU Signal Cable


The ELU (Electronic Label Unit) signal cable transmits to the CMUA the information about the
cabinet type reported by the ELU.

Structure
Figure 6-18 shows the ELU signal cable.

Figure 6-18 ELU signal cable

(1) RJ-45 connector

Pin Assignment
Table 6-8 describes the pin assignment for the wires of the ELU signal cable.

Table 6-8 Pin assignment for the wires of the ELU signal cable

X1 End X2 End Wire Color Type

X1.1 X2.1 White Twisted pair

X1.2 X2.2 Orange

X1.3 X2.3 White Twisted pair

X1.6 X2.6 Green

6-16 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 6 Overview of the TMC11H

X1 End X2 End Wire Color Type

X1.5 X2.5 White Twisted pair

X1.4 X2.4 Blue

X1.7 X2.7 White Twisted pair

X1.8 X2.8 Brown

6.5.5 Door Status Monitoring Cable


The signal cables transmit the information about the opening and closing of the door to the
CMUA from the door status sensor of the RFC, IBBS200D, or IBBS200T.

Structure
The door status monitoring cable are two black cables. One end of the cable is bare, and the
other end is added with a cord end terminal. Figure 6-19 show the door status monitoring cable.

Figure 6-19 door status monitoring cable

6.5.6 Transfer Cable for the Fan on the Front Door


The transfer cable feeds power into the fan on the front door of the APM30H or TMC11H and
transmits fan monitoring signals to the CMUA.

Structure
Figure 6-20 shows the transfer cable for the fan on the front door.

Figure 6-20 transfer cable for the fan on the front door

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 6-17


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
6 Overview of the TMC11H User Guide

Pin Assignment
Table 6-9 describes the pin assignment for the wires of the transfer cable for the fan on the front
door.

Table 6-9 Pin assignment for the wires of the transfer cable for the fan on the front door
Wire X1 End X2 End Color

W1 X1.1 X2.1 Black

W2 X1.2 X2.2 Black

W3 X1.3 X2.3 Black

W4 X1.4 X2.4 Black

6-18 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 7 SLPU

7 SLPU

About This Chapter

The signal lightning protection unit (SLPU), which can be optionally configured with the UFLP,
UELP, or USLP2, provides the signal surge protection.

7.1 Structure of SLPU


The SLPU has a case structure, which requires a 19 inch-wide and 1 U-high space.
7.2 Board Configuration of the SLPU
This describes the board configuration of the SLPU.
7.3 UELP
The Universal E1/T1 Lightning Protection (UELP) is a universal E1/T1 surge protection unit,
each UELP provides surge protection for four E1s/T1s.
7.4 UFLP
The universal FE/GE lightning protection (UFLP) board is a universal FE/GE surge protection
unit, each UFLP supports 2-way FE/GE surge protection.
7.5 USLP2
The Universal Signal Lightning Protection unit 2 (USLP2) is a RS485, boolean alarm and E1/
T1 surge protection unit. It is optional and can be installed in the SLPU. Each USLP2 provides
protection for four RS485 signal, four E1s/T1s, or eight Boolean alarm signals.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 7-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
7 SLPU User Guide

7.1 Structure of SLPU


The SLPU has a case structure, which requires a 19 inch-wide and 1 U-high space.
Figure 7-1 shows the structure of SLPU.

Figure 7-1 Structure of SLPU

7.2 Board Configuration of the SLPU


This describes the board configuration of the SLPU.

Slots of the SLPU


Figure 7-2 shows the slots of the SLPU.

Figure 7-2 Slots of the SLPU

Board Configuration of the SLPU


Table 7-1 describes the board configuration of the SLPU.

7-2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 7 SLPU

Table 7-1 Board configuration of the SLPU


Board Mandatory/ Maximum Installation Requirements
Optional Configured Slot
Number

UELP Optional 4 slot 0 - slot 3 The priority of


the
configuration:
slot 2, slot 0, slot
1, slot 3.

UFLP Optional 1 slot 3 If both the


UELP and the
UFLP are to be
configured, the
priority of the
configuration of
the UFLP is
higher than that
of the
configuration of
the UELP.

USLP2 Optional 2 slot 2 and slot 3 -

7.3 UELP
The Universal E1/T1 Lightning Protection (UELP) is a universal E1/T1 surge protection unit,
each UELP provides surge protection for four E1s/T1s.

Panel
Figure 7-3 shows the panel of the UELP.

Figure 7-3 Panel of the UELP

Ports
Table 7-2 describes the ports on the panel of the UELP.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 7-3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
7 SLPU User Guide

Table 7-2 Ports on the panel of the UELP

Label Connector Type

INSIDE DB25

OUTSIDE DB26

DIP Switch
The UELP has one DIP switch, which is used to check whether the receive terminal is grounded.
The DIP switch has four bits. Figure 7-4 shows the DIP switch on the UELP.

Figure 7-4 DIP switch on the UELP

Table 7-3 describes the DIP switch on the UELP.

Table 7-3 DIP switch on the UELP

DIP DIP Status Description


Switch
1 2 3 4

S1 ON ON ON ON 75-ohm E1 cable

7-4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 7 SLPU

DIP DIP Status Description


Switch
1 2 3 4

OFF OFF OFF OFF 120-ohm E1 cable or 100-ohm T1 cable

7.4 UFLP
The universal FE/GE lightning protection (UFLP) board is a universal FE/GE surge protection
unit, each UFLP supports 2-way FE/GE surge protection.

Panel
Figure 7-5 shows the panel of the UFLP.

Figure 7-5 Panel of the UFLP

Ports
Table 7-4 describes the ports on the panel of the UFLP.

Table 7-4 Ports on the panel of the UFLP


Port Location Label Connector Type

INSIDE side FE0, FE1 RJ-45

OUTSIDE side FE0, FE1 RJ-45

7.5 USLP2
The Universal Signal Lightning Protection unit 2 (USLP2) is a RS485, boolean alarm and E1/
T1 surge protection unit. It is optional and can be installed in the SLPU. Each USLP2 provides
protection for four RS485 signal, four E1s/T1s, or eight Boolean alarm signals.

Panel
Figure 7-6 shows the panel of the USLP2.

Figure 7-6 Panel of the USLP2

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 7-5


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
7 SLPU User Guide

Ports
Table 7-5 describes the ports on the panel of the USLP2.

Table 7-5 Ports on the panels of the USLP2

Port Quantity Connected Cable

RJ-45 2 Surge protection transfer cable


from the main control board in
the cabinet

4-pin 4 Transmission cable from an


external device

DIP Switch
The USLP2 has two DIP switches, which determine whether the receiving end is grounded. The
DIP switch has four DIP bits. Figure 7-7 shows the DIP switches on the USLP2.

Figure 7-7 DIP switches on the USLP2

Table 7-6 describes the DIP switches on the USLP2.

Table 7-6 DIP switches on the USLP2

DIP Bit Status Description


Switch
1 2 3 4

S1 and S3 ON ON ON ON 75-ohm E1/T1 (unbalanced) surge


protection

7-6 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 7 SLPU

DIP Bit Status Description


Switch
1 2 3 4

OFF OFF OFF OFF 120-ohm E1/T1 (balanced) surge


protection

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 7-7


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

8 Maintaining the APM30H Hardware

About This Chapter

If the APM30H should be powered off for maintenance, the duration of the power-off state
cannot exceed 48 hours.

8.1 Routine Maintenance


The APM30H needs regular inspection so that faults, if any, can be cleared in time.
8.2 Querying Board Information
Before replacing a board, you need to query the board information at the remote end to confirm
the type of board to be replaced.
8.3 Replacing the PMU
If the PMU is faulty and cannot be repaired in time, you must replace it.
8.4 Replacing the PSU
If the PSU is faulty and cannot be repaired in time, you must replace it.
8.5 Replacing the EPS Subrack
If the EPS subrack is faulty and cannot be repaired in time, you must replace it.
8.6 Replacing the AC Surge Protector
If the AC surge protector is faulty, you must replace it.
8.7 Replacing the Alarm Warning Fuse
When certain power equipment, which has high current requirements, is connected to a DC
output port on the EPS subrack, the fuse on the port need to be replaced if it cannot meet the
high-current requirement. Replacing the fuse that controls the port for supplying power to the
BBU disrupts all the services carried by the base station.
8.8 Replacing the Fan Box in the APM30H
If the fan box in the APM30H is faulty, you must replace it.
8.9 Replacing the Fan on the Front Door of the APM30H
If the fan on the front door of the APM30H is faulty and cannot be repaired in time, you must
replace it.
8.10 Replacing the Heater

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-1


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

If a heater in the APM30H or the TMC11H is faulty and cannot be repaired in time, you must
replace it.
8.11 Replacing the Fan Box in the TMC11H
If the fan box in the TMC11H is faulty, you must replace it.
8.12 Replacing the Batteries
If batteries are faulty or old, you must replace them. Generally, batteries are replaced in batches.
8.13 Replacing the TEC Cooler of the IBBS200T
The TEC cooler helps dissipate the heat of storage batteries to ensure the normal operation of
the IBBS200T in high-temperature areas. If the TEC cooler is faulty and cannot be repaired in
time, you must replace it.
8.14 Replacing the Fan on the Front Door of the IBBS200D
If a centrifugal fan on the front door of the IBBS200D is faulty, you must replace it.
8.15 Replacing the CMUA
If the Central Monitoring Unit type A (CMUA) on the front panel of the IBBS200D or IBBS200T
cabinet is faulty, you must replace it.
8.16 Replacing the ELIA
The Electronic Label Identity type A (ELIA) is installed in the ELU box. The board reports the
information about the cabinet type. If the ELIA is faulty, you must replace it.

8-2 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

8.1 Routine Maintenance


The APM30H needs regular inspection so that faults, if any, can be cleared in time.

Table 8-1 Routine maintenance items

Item Check Metho Operation


ing d
Frequ
ency

Checking whether Once Multim For details, see Checking the Power-On Status of
the output voltage is every eter the APM30H.
normal six
months

Checking whether Once Visual l For details about how to handle the faulty fan
the fans are every inspecti on the top of the APM30H, see 8.8 Replacing
operational six on the Fan Box in the APM30H .
months l For details about how to handle the faulty fan
on the front door of the APM30H, see 8.9
Replacing the Fan on the Front Door of the
APM30H.
l For details about how to handle the faulty fan
in the IBBS200D, see 8.14 Replacing the Fan
on the Front Door of the IBBS200D.

Checking whether Once Visual l For details on the LEDs on the PMU, see Table
the LEDs are every inspecti 3-8.
operational six on l For details on the LEDs on the CMUA, see
months Table 6-4.
l When the alarm LED is ON, query alarms on
the BAM, and then clear them.

The paint and Once Visual -


galvanization every inspecti
coating on the six on
surface of the months
cabinet are not
peeling off or have
scratches.

8.2 Querying Board Information


Before replacing a board, you need to query the board information at the remote end to confirm
the type of board to be replaced.

1. Run the DSP BTSELABEL command on the LMT.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-3


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

2. Confirm the type of the board to be replaced according to the Boadtype and Description
fields in the query result. Ensure that the new board is of the same type by checking the
information indicated by the bar code on the label of the panel or handle of the new board.
Figure 8-1 shows a label containing the bar code.

Figure 8-1

8.3 Replacing the PMU


If the PMU is faulty and cannot be repaired in time, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, flat-head
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty modules are confirmed. For details, see 8.2 Querying
Board Information.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-2 shows the installation position of the PMU in the EPS subrack.

Figure 8-2 Installation position of the PMU


PMU

l The module is hot-swappable.

8-4 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Record all the cable connections on the panel of the faulty PMU.
Step 3 Disconnect all cables from the panel of the PMU.

CAUTION
When connecting the DB50 connector of the environment monitoring signal cable, you should
press the latches on both sides of the connector with your hands and plug or unplug the connector
perpendicularly to or from the panel on the HPMI to prevent false monitoring alarms caused by
bent pins.

Step 4 Use a flat-head screwdriver to loosen the two screws on the ejector lever of the panel of the
PMU.
Step 5 Pull the ejector lever gently to disconnect the buckle of the PMU from the subrack, and then
remove the PMU from the slot, as shown in Figure 8-3.

Figure 8-3 Removing the PMU

Step 6 Place the faulty PMU into an ESD box or bag.


Step 7 Set the DIP switches of the new PMU to 11000000, as shown in Figure 8-4.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-5


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Figure 8-4 Setting DIP switches

Step 8 Place the new PMU in the corresponding slot, loosen the screws on the ejector lever of the PMU,
and then pull out the ejector lever.
Step 9 Slide the module along the guide rails into the slot until it is in position, and then push the ejector
lever back.
Step 10 Tighten the two screws on the ejector lever. Figure 8-5 shows the installation procedure.

8-6 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Figure 8-5 Installing the PMU

Step 11 Connect the cables to the ports on the panel of the new PMU based on the cable connection
records.
Step 12 Check the status of the indicators to determine whether the new module works properly. For
details on the status of the indicators, see PMU.
Step 13 Take off the ESD wrist strap or gloves, and pack up all the tools.
----End

Postrequisite
l Place the replaced module into the ESD box or bag. Then, place the ESD box or bag into
a carton padded with foam or into the packing box of the new module.
l Fill in the fault form with the details of the replaced module.
l Contact the local Huawei office to handle the faulty module.

8.4 Replacing the PSU


If the PSU is faulty and cannot be repaired in time, you must replace it.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-7


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, flat-head
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty modules are confirmed. For details, see 8.2 Querying
Board Information.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-6 shows the installation position of the PSU in the EPS subrack.

Figure 8-6 Installation position of the PSU


PSU

l The module is hot-swappable.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Use a flat-head screwdriver to loosen the two screws on the ejector lever of the panel of the PSU.
Step 3 Pull the ejector lever gently to disconnect the buckle of the PSU from the subrack, and then
remove the PSU from the slot, as shown in Figure 8-7.

Figure 8-7 Removing the PSU

8-8 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Step 4 Place a new PSU in the corresponding slot, loosen the screws on the ejector lever of the PSU,
and then pull out the ejector lever.

Step 5 Slide the module along the guide rails into the slot until it is in position, and then push the ejector
lever back.

Step 6 Tighten the screws on the ejector lever. Figure 8-8 shows the installation procedure.

Figure 8-8 Installing the PSU

COM IN COM OUT COM


485

COM IN COM OUT COM


485

Step 7 Check the status of the indicators to determine whether the new module works properly. For
details on the status of the indicators, see PSU (AC/DC).

Step 8 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced component into the ESD box or bag. Then, place the ESD box or bag
into a carton padded with foam or into the packing box of the new component.
l Fill in the fault form with the details of the replaced module.
l Contact the local Huawei office to handle the faulty module.

8.5 Replacing the EPS Subrack


If the EPS subrack is faulty and cannot be repaired in time, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty subracks are confirmed, and new subracks of the same
quantity and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-9


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Context
l Replacing the EPS subrack disrupts all the services carried by the base station.
l It takes about 30 minutes to replace the EPS subrack.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Set the MCB labeled BAT on the panel of the EPS subrack to OFF.

Step 3 Set the three PSU MCBs on the panel of the EPS subrack to OFF.

Step 4 Turn off the AC input of the APM30H.

Step 5 Disconnect the ground cable of the EPS subrack from the ground bar on the left side of the
cabinet.

Step 6 Remove the PMU and the PSU in the EPS subrack. For details, see 8.3 Replacing the PMU
and 8.4 Replacing the PSU respectively.

Step 7 Use a Phillips screwdriver to remove the cable support on the right side of the EPS subrack.

Step 8 Label the cables that are delivered with the EPS subrack and connected to the right side of the
EPS subrack, and then disconnect the cables.

Step 9 Loosen the screws on the AC protecting hood on the left side of the EPS subrack, and then
remove the protecting hood.

Step 10 Label the AC input power cable and AC output power cable on the left side of the EPS subrack,
and then disconnect the cables.

CAUTION
The PE wire of the AC input power cable is connected to a hexagonal screw on a mounting ear
of the EPS subrack. The hexagonal screw must be stored properly after the PE wire is
disconnected.

Step 11 Label the DC output cable on the right side of the EPS subrack, and then disconnect the cable.

Step 12 Remove the remaining seven retention screws on both sides of the EPS subrack, and slowly pull
the subrack out of the cabinet, as shown in Figure 8-9.

8-10 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Figure 8-9 Replacing the EPS subrack

CAUTION
The EPS subrack is heavy. Therefore, you need to hold the subrack with one hand, support the
bottom with the other hand, and slowly pull the subrack out. This prevents the subrack from
falling and ensures personal safety.

Step 13 Place the faulty EPS subrack into an ESD box or bag.

Step 14 Slide the new EPS subrack into the original installation position, and then tighten the retention
screws on both sides of the subrack.

Step 15 Reinstall the PMU and the PSU in the corresponding slots in the new EPS subrack.

Step 16 Secure the interconnection terminals to the original support, and then install the support on the
right side of the cabinet.

Step 17 Connect the cables to the ports on the panel of the new EPS subrack based on the cable connection
records.

CAUTION
The PE wire of the AC input power cable must be connected to the hexagonal screw that is
removed in Step 10. Otherwise, the level of reliability is low.

Step 18 Secure the AC protecting hood to the left side of the EPS subrack, and then tighten the screws.

Step 19 Turn on the AC input of the APM30H.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-11


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Step 20 Set the three PSU MCBs on the panel of the EPS subrack to ON.

Step 21 Set the MCB labeled BAT on the EPS subrack to ON.

Step 22 Check the status of the indicators on the PMU and PSU to determine whether the new EPS
subrack works properly. For details on the status of the indicators, see PMU and PSU (AC/
DC).

Step 23 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced component into the ESD box or bag. Then, place the ESD box or bag
into a carton padded with foam or into the packing box of the new component.
l Fill in the fault form with the details of the replaced component.
l Contact the local Huawei office to handle the faulty component.

8.6 Replacing the AC Surge Protector


If the AC surge protector is faulty, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, ESD box or
bag, and key to the cabinet door are ready.
l The quantity and model of the faulty modules are confirmed, and new modules of the same
quantity and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-10 shows the installation position of the AC surge protector in the EPS subrack.

Figure 8-10 Installation position of the AC surge protector

l When the color of the protecting hood on the front panel of the surge protector changes
from green to red, the protector is faulty and you must replace it.

8-12 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Press the upper and lower ends of the surge protector, and then remove the protector, as shown
in Figure 8-11.

Figure 8-11 Removing the surge protector

Step 3 Place the faulty AC surge protector into an ESD box or bag.
Step 4 Place the new surge protector in the corresponding slot, and then push it until it is securely
installed.
Step 5 Check the color of the protecting hood on the front panel of the surge protector to determine
whether the new surge protector works properly. When the surge protector works properly, the
color is green.
Step 6 Take off the ESD wrist strap or gloves, and pack up all the tools.
----End

Postrequisite
l Place the replaced module into the ESD box or bag. Then, place the ESD box or bag into
a carton padded with foam or into the packing box of the new module.
l Fill in the fault form with the details of the replaced module.
l Contact the local Huawei office to handle the faulty module.

8.7 Replacing the Alarm Warning Fuse


When certain power equipment, which has high current requirements, is connected to a DC
output port on the EPS subrack, the fuse on the port need to be replaced if it cannot meet the

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-13


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

high-current requirement. Replacing the fuse that controls the port for supplying power to the
BBU disrupts all the services carried by the base station.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, new fuse, ESD
box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty fuses are confirmed, and new fuses of the same quantity
and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-12 shows the installation position of the alarm warning fuse in the EPS subrack.

Figure 8-12 Installation position of the alarm warning fuse

l The alarm warning fuse is hot-swappable.

CAUTION
The specifications of the fuse vary according to the ambient temperature. For details on the
derating of the fuse, see the general specifications of the fuse. If the fuse works at a normal
temperature of 25°C, the operating current cannot be greater than 75% of its rated current.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

8-14 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Step 2 Take the extraction tool out of the mounting ear on the right side of the EPS subrack.
Figure 8-13 shows the exterior and position of the extraction tool.

Figure 8-13 Position of the extraction tool in the cabinet

Step 3 Use the extraction tool to remove the faulty fuse, as shown in Figure 8-14.

Figure 8-14 Removing the faulty fuse

Step 4 Place the faulty alarm warning fuse into an ESD box or bag.
Step 5 Insert the new fuse into the corresponding port.
Step 6 Set the MCB for the new fuse to ON and check the running status of the related modules to
determine whether the fuse works properly.
Step 7 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-15


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Postrequisite
l Place the replaced component into the ESD box or bag. Then, place the ESD box or bag
into a carton padded with foam or into the packing box of the new component.
l Fill in the fault form with the details of the replaced component.

8.8 Replacing the Fan Box in the APM30H


If the fan box in the APM30H is faulty, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty fan boxes are confirmed. For details, see 8.2 Querying
Board Information.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l The fan box in the APM30H houses the HPMI, CMUA, and fan. If any of the components
is faulty, the fan box must be replaced.
l It takes about 20 minutes to replace the fan box.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Remove the fuse corresponding to the port labeled LOAD0. For details, see 8.7 Replacing the
Alarm Warning Fuse.
Step 3 Record all the cable connections on the panel of the faulty fan box.
Step 4 Disconnect all cables from the panel of the faulty fan box.

8-16 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

NOTE

Remove the RJ-45 connectors linked to the COM_IN, COM_OUT, and ELU ports on the panel of the CMUA
through the holes in the baffle plate on the ports, as shown in Figure 8-15.

Figure 8-15 Top view of the fan box in the APM30H

Step 5 Remove the retention screws on the mounting ears of the fan box, and then remove the box from
the cabinet slowly, as shown in Figure 8-16.

Figure 8-16 Removing the fan box from the APM30H

DANGER
When removing the fan box, do not touch the air inlet at the bottom of the fan box.

Step 6 Place the faulty fan box into an ESD box or bag.

Step 7 Slide the new fan box into the installation position, and then tighten the retention screws on the
mounting ears of the fan box.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-17


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Step 8 Connect the cables to the ports on the front panel of the fan box based on the cable connection
records, and then check and ensure that the cables are properly and correctly connected.
NOTE

You must plug or unplug the DB50 connector of the environment monitoring signal cable perpendicularly
to or from the panel on the HPMI with your hands to prevent false monitoring alarms caused by bent pins.

Step 9 Link the connector at one end of the power cable of the fan box in the APM30H to the port
labeled LOAD0 on the panel of the fan box of the EPS subrack.
Step 10 Check the status of the indicators to determine whether the new fan box works properly. For
details on the status of the indicators, see CMUA.
Step 11 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced component into the ESD box or bag. Then, place the ESD box or bag
into a carton padded with foam or into the packing box of the new component.
l Fill in the fault form with the details of the replaced component.
l Contact the local Huawei office to handle the faulty component.

8.9 Replacing the Fan on the Front Door of the APM30H


If the fan on the front door of the APM30H is faulty and cannot be repaired in time, you must
replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty fans are confirmed, and new fans of the same quantity
and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-17 shows the installation position of the fan on the front door in the APM30H.

8-18 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Figure 8-17 Installation position of the fan on the front door in the APM30H

l It takes about 20 minutes to replace the fan.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Remove the fuse corresponding to the port labeled LOAD0. For details, see 8.7 Replacing the
Alarm Warning Fuse.
Step 3 Remove the connector linked to the port labeled FAN_EXT on the panel of the CMUA to power
off the fan on the front door of the APM30H.
Step 4 Loosen the screws on the cover plate of the transfer board of the fan, and then remove the cover
plate.
Step 5 Label the cables connected to the faulty fan, and then disconnect the cables, as shown in 1 of
Figure 8-18.
Step 6 Remove the eight retention screws on the cover plate of the fan and remove the cover plate, as
shown in 2 of Figure 8-18.
Step 7 Remove the baffle and rubber caps on the cable outlets on the side of the fan cavity. Then, pull
out the cable for fans, as shown in 3 of Figure 8-18.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-19


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Figure 8-18 Removing the fan on the front door of the APM30H

Step 8 Remove the four retention screws on the support plate of the fan and pull the support plate and
the fan out of the cabinet, as shown in 4 of Figure 8-18.

Step 9 Remove the four screws fixing the fan from the support plate, and then remove the fan.

Step 10 Lead the cables of the new fan through the cable outlets in the support plate. Then, tighten the
four screws of the fan.

Step 11 Install the cover plate of the fan back to the fan cavity after the fan is installed and tighten the
four retention screws.

Step 12 Lead the fan cable through the cable outlets of the fan cavity. Then, add the rubber caps and
baffle to the cable.

Step 13 Tighten the two screws on the baffle.

Step 14 Reconnect the cables of the fan to the fan transfer board based on the cable connection records.
Then, install the cover plate of the fan transfer board.

Step 15 Re-link the connector to the port labeled FAN_EXT on the panel of the CMUA.

Step 16 Check the running of the fans and the status of the indicators on the CMUA to determine whether
the new fan works properly. For details on the status of the indicators, see CMUA.

Step 17 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

8-20 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Postrequisite
l Place the replaced component into the ESD box or bag. Then, place the ESD box or bag
into a carton padded with foam or into the packing box of the new component.
l Fill in the fault form with the details of the replaced component.
l Contact the local Huawei office to handle the faulty component.

8.10 Replacing the Heater


If a heater in the APM30H or the TMC11H is faulty and cannot be repaired in time, you must
replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, diagonal pliers,
flat-head screwdriver, Phillips screwdriver, insulation screwdriver, ESD box or bag, and
key to the cabinet door are ready.
l The quantity and model of the faulty heaters are confirmed, and new heaters of the same
quantity and model and several cable ties are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
The heater can be installed in the 1 U transmission space based on the actual condition.

WARNING
After the installation, do not change the position of the heater during the routine operation.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Set the AC output MCB labeled AC OUTPUT on the panel of the EPS subrack to OFF.

Step 3 Remove the connector at one end of the power cable from the heater.

Step 4 Remove the four screws on the panel of the heater. Hold the heater with one hand, and pull the
heater out of the cabinet with the other hand slightly, as shown in Figure 8-19.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-21


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Figure 8-19 Removing the faulty heater

Step 5 Place the new heater in its installation position. Hold the new heater with one hand, and push it
into the cabinet with the other hand until the mounting ears are in contact with the columns.

Step 6 Tighten the two screws on both sides of the heater.

Step 7 Re-link the connector at one end of the power cable to the input port of the heater, as shown in
Figure 8-20.

Figure 8-20 Installing the new heater

Step 8 Set the AC output MCB labeled AC OUTPUT on the panel of the EPS subrack to ON.

Step 9 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced heater into the ESD box or bag. Then, place the ESD box or bag into a
carton padded with foam or into the packing box of the new heater.
l Fill in the fault form with the details of the replaced heater.
l Contact the local Huawei office to handle the faulty heater.

8-22 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

8.11 Replacing the Fan Box in the TMC11H


If the fan box in the TMC11H is faulty, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty fan boxes are confirmed. For details, see 8.2 Querying
Board Information.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l The fan box in the TMC11H houses the HPMI, CMUA, and fan. If any of the components
is faulty, the fan box must be replaced.
l It takes about 20 minutes to replace the fan box.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Set the MCB labeled FAN on the DCDU-03 to OFF to power off the fan box.

Step 3 Record all the cable connections on the panel of the faulty fan box.

Step 4 Disconnect all cables from the panel of the faulty fan box.
NOTE

Remove the RJ-45 connectors linked to the COM_IN, COM_OUT, and ELU ports on the panel of the
CMUA through the holes in the baffle plate on the ports, as shown in Figure 8-21.

Figure 8-21 Top view of the fan box in the TMC11H

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-23


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Step 5 Remove the retention screws on the mounting ears of the fan box, and then remove the box from
the cabinet slowly, as shown in Figure 8-22.

Figure 8-22 Removing the fan box from the TMC11H

DANGER
When removing the fan box, do not touch the air inlet at the bottom of the fan box.

Step 6 Slide the new fan box into the installation position, and then tighten the retention screws on the
mounting ears of the fan box.
Step 7 Connect the cables to the ports on the front panel of the fan box based on the cable connection
records, and then check and ensure that the cables are properly and correctly connected.
Step 8 Set the MCB labeled FAN on the DCDU-03 to ON to power on the fan box.
Step 9 Check the status of the indicators to determine whether the new fan box works properly. For
details on the status of the indicators, see CMUA.
Step 10 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced component into the ESD box or bag. Then, place the ESD box or bag
into a carton padded with foam or into the packing box of the new component.
l Fill in the fault form with the details of the replaced component.
l Contact the local Huawei office to handle the faulty component.

8.12 Replacing the Batteries


If batteries are faulty or old, you must replace them. Generally, batteries are replaced in batches.

8-24 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty batteries are confirmed, and new batteries of the same
quantity and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context

DANGER
During the replacement, short circuits or reverse connections cannot exist between the positive
and negative poles of the batteries. All the tools such as wrenches and screwdrivers must be
coated with insulating tubes. This prevents the batteries from being burned and ensures personal
safety.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Set the MCB labeled BAT on the panel of the EPS subrack in the APM30 cabinet to OFF.
Step 3 Remove the cover plate on the batteries, as shown in Figure 8-23.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-25


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Figure 8-23 Removing the cover plate on the batteries

Step 4 Label the input power cables on the positive and negative poles of the batteries and the cables
for series connection of batteries, and then disconnect the cables, as shown in Figure 8-24.

Figure 8-24 Removing cables of the batteries

Step 5 Hold the steering rope to pull the batteries out. Remove the batteries on this layer with your
hands and place them in a safe location.

8-26 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

NOTE

l Remove the baffle plates and batteries from top to bottom. Remove the batteries before removing the
baffle plate of the lower layer.
l Remove and place the batteries with your hands to prevent the batteries from falling.

Step 6 Install the new batteries layer by layer and connect the input power cables and the cables for
series connection of batteries based on the cable connection records.
NOTE

l Install all the batteries and baffle plates from bottom to up. Install the batteries before installing the
baffle plate of the upper layer.
l Ensure that the cables are securely and correctly connected.

Step 7 Use a multimeter to measure the voltage at both ends of the battery pack to prevent inverse
connection.
Step 8 Set the MCB labeled BAT on the panel of the EPS subrack to ON.
Step 9 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced batteries into the ESD box or bag. Then, place the ESD box or bag into
a carton padded with foam or into the packing box of the new batteries.
l Fill in the fault form with the details of the replaced batteries.
l Contact the local Huawei office to handle the faulty batteries.

8.13 Replacing the TEC Cooler of the IBBS200T


The TEC cooler helps dissipate the heat of storage batteries to ensure the normal operation of
the IBBS200T in high-temperature areas. If the TEC cooler is faulty and cannot be repaired in
time, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty modules are confirmed, and new modules of the same
quantity and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-25 shows the installation position of the TEC cooler in the IBBS200T.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-27


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Figure 8-25 Installation position of the TEC cooler


TEC

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Set the MCB labeled FAN/TEC_SW2 for the TEC cooler of the power distribution box on the
inner right side in the IBBS200T to OFF to power off the TEC cooler.
Step 3 Loosen the two retention screws fixing the CMUA on the front door, remove the cover plate,
and then disconnect the power cables and alarm signal cables of the TEC cooler from the CMUA,
as shown in 1 of Figure 8-26.

8-28 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Figure 8-26 Removing the retention screws on the CMUA

Step 4 Remove the two retention screws of the TEC protecting hood on the inner side of the front door,
as shown in 2 of Figure 8-26.
Step 5 Rotate the movable side of the TEC protecting hood clockwise by 90 degrees. Remove the six
retention screws, as shown in Figure 8-27, and then remove the TEC cooler from the subrack
of the front door.

Figure 8-27 Removing the faulty TEC cooler

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-29


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Step 6 Lead the power cables and the alarm signaling cables through the empty subrack on the front
door, and then install six M4 screws to fix the TEC cooler in the reverse direction in Figure
8-27.
Step 7 Close the TEC protecting hood, and fix the hood by using two screws.
Step 8 Connect the power cables and the alarm signaling cables that are delivered with the new cooler
to the corresponding ports on the CMUA.
Step 9 Fix the CMUA by using two screws.
Step 10 Set the MCB for the TEC cooler of the power distribution box to ON.
Step 11 Check the running of the fans and the status of the indicators on the CMUA to determine whether
the new TEC cooler works properly. For details on the status of the indicators, see CMUA.
Step 12 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced module into the ESD box or bag. Then, place the ESD box or bag into
a carton padded with foam or into the packing box of the new module.
l Fill in the fault form with the details of the replaced module.
l Contact the local Huawei office to handle the faulty module.

8.14 Replacing the Fan on the Front Door of the IBBS200D


If a centrifugal fan on the front door of the IBBS200D is faulty, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty fans are confirmed, and new fans of the same quantity
and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-28 shows the installation position of the fan on the front door of the IBBS200D.

8-30 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Figure 8-28 Installation position of the fan on the front door of the IBBS200D

FAN

IBBS200D

l The fan box on the front door of the IBBS200D houses two centrifugal fans. When
maintaining the fan box, you need to replace only the faulty fan. This example describes
how to replace the fan on the left side.
l It takes about 20 minutes to replace the fan.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Set the MCB labeled TEC/FAN_SW2 of the fan box to OFF on the power distribution box in
the IBBS200D to power off the fan box.
Step 3 Label the cables below the fan box, and then disconnect the cables.
Step 4 Remove the five retention screws on the fan box, and then remove the fan box, as shown in
Figure 8-29.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-31


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Figure 8-29 Removing the fan box of the IBBS200D

Step 5 Disconnect the cables that connect the faulty fan to one side of the CMUA.

Step 6 Loosen the four retention screws of the faulty fan, and then remove the faulty fan from the fan
box, as shown in Figure 8-30.

Figure 8-30 Removing the faulty fan

Step 7 Place the new fan in the original position of the faulty fan, and hold the fan with one hand. Then,
tighten the four retention screws with the other hand by using a screwdriver.

8-32 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Step 8 Connect the cables of the new fan to the corresponding ports on the panel of the CMUA, and
then bind the cables to the binding slot on the fan box by using cable ties.
Step 9 Install the fan box onto the front door, and tighten the five retention screws on the cover plate.
Step 10 Connect the cables to the corresponding ports on the panel below the fan box based on the cable
connection records.
Step 11 Set the MCB for the fan in the fan box to ON.
Step 12 Check the running of the fans and the status of the indicators on the CMUA to determine whether
the new fan works properly. For details on the status of the indicators, see CMUA.
Step 13 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced component into the ESD box or bag. Then, place the ESD box or bag
into a carton padded with foam or into the packing box of the new component.
l Fill in the fault form with the details of the replaced component.
l Contact the local Huawei office to handle the faulty component.

8.15 Replacing the CMUA


If the Central Monitoring Unit type A (CMUA) on the front panel of the IBBS200D or IBBS200T
cabinet is faulty, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty boards are confirmed. For details, see 8.2 Querying
Board Information.
l DIP settings of the CMUA varies according to cabinet. Figure 8-31 shows the DIP settings
and bit positions of the CMUA in different cabinets.

Figure 8-31 DIP settings and bit positions of the CMUA in different cabinets

NOTE

The red rectangle in Figure 8-32 shows the position for connecting to the jumper cap.

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-33


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

l The authorized personnel are permitted to enter the site. The required keys are available.

Context
l Figure 8-32 shows the installation position of the CMUA on the front door of the
IBBS200D or IBBS200T.

Figure 8-32 Installation position of the CMUA


CMUA CMUA

IBBS200D IBBS200T

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Set the MCB labeled FAN/TEC_SW2 on the power distribution box to OFF to power off the
CMUA.

Step 3 Record all the cable connections on the panel of the faulty CMUA.

Step 4 Disconnect all cables from the panel of the faulty CMUA.

Step 5 Use a screwdriver to loosen the screws on the fan box of the IBBS200D or the CMUA box of
the IBBS200T, and then remove the fan box or CMUA box, as shown in Figure 8-33 or Figure
8-34 respectively.

8-34 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

Figure 8-33 Removing the fan box of the IBBS200D

Figure 8-34 Removing the CMUA box of the IBBS200D

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-35


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Step 6 Label all the cables connected to the ports on the panel of the backplane of the CMUA, and then
disconnect the cable for the fans and the cable for the TEC cooler.
Step 7 Use a screwdriver to loosen the four retention screws at the four corners of the faulty CMUA,
and then remove the CMUA.
Step 8 Install the new CMUA in the fan box of the IBBS200D or in the CMUA box of the IBBS200T,
and then use four retention screws to secure the board.
Step 9 Reconnect the cable for the fans and the cable for the TEC cooler to the ports on the panel of
the backplane based on the cable connection records.
Step 10 Reinstall the fan box or CMUA box on the front door of the IBBS200D or IBBS200T
respectively.
Step 11 Check the status of the indicators to determine whether the new CMUA works properly. For
details on the status of the indicators, see CMUA.
Step 12 Take off the ESD wrist strap or gloves, and pack up all the tools.
Step 13 Paste the bar code delivered with the board onto the cover plate. Figure 8-35 shows the positions
for pasting the bar codes of the CMUA.

Figure 8-35 Positions for pasting the bar codes of the CMUA

----End

Postrequisite
l Place the replaced board into the ESD box or bag. Then, place the ESD box or bag into a
carton padded with foam or into the packing box of the new board.

8-36 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide 8 Maintaining the APM30H Hardware

l Fill in the fault form with the details of the replaced board.
l Contact the local Huawei office to handle the faulty board.

8.16 Replacing the ELIA


The Electronic Label Identity type A (ELIA) is installed in the ELU box. The board reports the
information about the cabinet type. If the ELIA is faulty, you must replace it.

Prerequisite
l The tools and materials, such as an ESD wrist strap or a pair of ESD gloves, Phillips
screwdriver, ESD box or bag, and key to the cabinet door are ready.
l The quantity and model of the faulty boards are confirmed, and new boards of the same
quantity and model are ready.
l The authorized personnel are permitted to enter the site. The required keys are available.

Context
The installation position of the ELU varies according to cabinet. It is installed on the inner left
side of the IBBS200D or IBBS200T or on the inner right side of the APM30H, TMC11H, or
RFC.

Procedure
Step 1 Wear an ESD wrist strap or a pair of ESD gloves.

CAUTION
Take proper ESD protection measures, for example, wear an ESD wrist strap or a pair of ESD
gloves, to prevent electrostatic damage to the boards, modules, or electronic components.

Step 2 Remove the RJ-45 connector from the port on the housing of the ELU.
Step 3 Open the housing of the ELU upwards according to the direction displayed on the surface of the
housing, as shown in Figure 8-36.

Figure 8-36 Opening the housing of the ELU

Issue 03 (2009-12-30) Huawei Proprietary and Confidential 8-37


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
8 Maintaining the APM30H Hardware User Guide

Step 4 Use a Phillips screwdriver to loosen the retention screws on the ELIA, and then remove the
ELIA, as shown in Figure 8-37.

Figure 8-37 Removing the faulty ELIA

Step 5 Install a new board, and tighten the screws on the panel of the board.
Step 6 Reinstall the housing of the ELU.
Step 7 Re-link the RJ-45 connector to the port on the housing of the ELU.
Step 8 Take off the ESD wrist strap or gloves, and pack up all the tools.

----End

Postrequisite
l Place the replaced board into the ESD box or bag. Then, place the ESD box or bag into a
carton padded with foam or into the packing box of the new board.
l Fill in the fault form with the details of the replaced board.
l Contact the local Huawei office to handle the faulty board.

8-38 Huawei Proprietary and Confidential Issue 03 (2009-12-30)


Copyright © Huawei Technologies Co., Ltd.
APM30H&TMC11H&IBBS200D/T
User Guide Index

Index

D
DIP switch
UELP, 7-3

M
module
USLP2, 7-5

S
structure
SLPU, 7-2

U
UELP, 7-3
UFLP, 7-5

Issue 03 (2009-12-30) Huawei Proprietary and Confidential i-1


Copyright © Huawei Technologies Co., Ltd.

S-ar putea să vă placă și