Documente Academic
Documente Profesional
Documente Cultură
More at:
www.schaltbau.info/rail
Electrics for rolling stock I Page 4
ou
Quality
nt on
more integrated and cross-border traffic becomes required. The following overview lists the most Sc
h a lt b a u
ever more important. To prevent any delays when important railway standards.
Certified to
DIN EN ISO 9001
since 1994. For the most
IEC 60077-1 Railway applications – Electric equipment BS EN 50153 Railway applications – Rolling stock – recent certificate visit
our website.
for rolling stock – Part 1: General service conditions and Protective provisions relating to electrical hazards
general rules
IEC 60694 Common specifications for high-voltage switch- can c
you
IEC 60077-2 Railway applications – Electric equipment gear and controlgear standards
ou
Quality
nt on
for rolling stock – Part 2: Electrotechnical components - Sc
h a lt b a u
IEC 60077-4 Railway applications – Electric equipment for UIC 550 Power supply installations for passenger stock
rolling stock – Part 4: Electrotechnical components - Rules UIC 550-1 Electrical switch cabinets on passenger stock
for AC circuit breakers
UIC 550-2 Power supply systems for passenger coaches
IEC 60077-5 Railway applications – Electric equipment for – Type testing The production
rolling stock – Part 5: Electrotechnical components - Rules facilities of Schaltbau
for HV fuses UIC 550-3 Power supply installations for passenger stock GmbH have been IRIS
– Effect on electrical installations outside passenger coaches certified since 2008.
BS EN 50155 Railway applications – Electronic equipment
used on rolling stock UIC 552 Electrical power supply for trains – Standard technical
characteristics of the train line
BS EN 50124-1 Railway applications – Insulation coordina- RoHS
tion – Part 1: Basic requirements – Clearances and creepage UIC 541-5 Brakes – Electropneumatic brake (ep brake) – 2011/65/EC
distances for all electrical and electronic equipment Electropneumatic emergency brake override (EBO)
Schaltbau GmbH
BS EN 50124-2 Railway applications – Insulation coordi- UIC 558 Remote control and data cable – Standard technical manufactures in
nation – Part 2: Overvoltages and related protection features for the equipping of RIC coaches compliance
with RoHS.
BS EN 50121-3-2 Railway applications – Electromagnetic UIC 612-0 Driver Machine Interfaces for EMU/DMU, Locomo-
compatibility – Part 3-2: Rolling stock – Apparatus tives and driving coaches – Functional and system requirements
associated with harmonised Driver Machine Interfaces
IEC 61373 Railway applications – Rolling stock equipment
– Shock and vibration tests
°C
Switchgear cabinet Safety contactor,
Disconnecting and earthing device
Battery switch
Series TCMB, TCMO
Earthing switch
Series SE
Heater cont
Series CT
Series ZH
Schaltbau control devices such as master controllers, toggle switches, electronic buzzers as well as dead man’s
Electric equipment for handles and footswitches are to be found in all kind of trains all over the world. Modular master controllers are
assemblies of standardised components, can be configured individually or be totally customized.
driving cabins With them it will be easy to design state-of-the-art driver desks and cabins.
and passenger use Schaltbau also has proceeded along the path to standardisation and modularization as indicated by UIC 612.
Consequently, our master controllers are SIL compliant and our toggle switch consoles and assemblies have
a bus capability. What a short time ago was a simple display, today is offered as full-blown touch screen PC
with unlimited interactive functionality. Schaltbau is even ready for today's fully automated driverless metro
systems offering a small size, compact, detachable version of a complete driver desk. Thus the driver desk,
complete with master controller and brake controller, has developed into a scalable concept for subsystem
integration which can be easily adapted to even the most confined installation situation.
Popular Schaltbau products the passengers come in touch with are the controls for their use in the compart-
ments and displays like “WC occupied” as well as the emergency brake handle in carriages and multiple-unit
trains.
To handle UIC voltages safely and reliably is the trademark of Schaltbau switchgear such as the AC vacuum cir-
cuit breaker, the disconnecting and earthing device, the high-voltage switchgear cabinets, the safety contactor
High-voltag switchgear for such switchgear as well as sensors and controlgear.
for power supply Changeover units, for instance, are needed in international mainline service for reconfiguring the control
circuits of the auxiliaries with the change of catenary voltage after crossing the border. For this purpose
Schaltbau has added rotary scissor switches to its product range of controlgear. The two, three and four posi-
tion changeover switches have an open modular design and are easy to configure and customize.
HV signalling relay
Series ZH842
Voltage selector
Series ZH1114
HV changeover unit
Series CO / SCO
HV changeover unit
Pre-charging U
contactor
Series CL
U
Interactive displays
Master controller, toggle switches,
Pre-charging contactor Pre-charging
contactor
Auxiliaries push buttons, keylock switch
Series CL inverter
Series CL
Dead man's handle, footswitch, buzzers
Driver desk
tactor
Traction contactor Traction contactor
Series CA Series CA Electrically / mechanically adjustable foot rests
Traction inverter Traction inverter
HV signalling relay
PLAY IT SAFE
Electrics for rolling stock I Page 6
FEATURES
■ LCD size: 10,4“, touch screen ■ Removable and portable, all subsystems already integrated
■ Processor: Freescale™ i.MX6 – Quad ARM Cortex-A9 ■ Interactive touch screen HMI for data communication with the TCMS
up to 1.2 GHz with TrustZone ■ Separate console fitted with operating elements, display panels
■ 2x Ethernet, 2x MVB, 2x CAN, 2x 485 and audible feedback
■ Suitable for use with: railway signalling (ERTMS/SCMT), technical ■ Master controller/Brake controller with integrated dead-man function
and diagnostic display, functional safety (in the industrial environment ■ Train radio display
also), video surveillance
■ Emergency stop switch (mushroom)
SPECIFICATIONS
Series ATX-SPII Display PDD-100 Series
Size 5" / 10.4" / 15" Master/brake controller, touch screen HMI,
Resolution 1024 x 768 max. or up to 1,000 cd/m² rotary, keylock, emergency switches, push buttons, Operating and
microphone, loudspeaker, indicators, braking condition display elements
Operating elements Soft-Keys, Touch screen optional display, others, customized
Quad Core Freescale™ i.MX6 1 GHz / USB / Ethernet 10/100/1000 Mbps /
CPU Dual Core ARM Cyclone V (Linux), RS232 / RS422 + RS 485 / CAN bus / Interfaces
Intel Atom E3845 1,91 GHz Quad Core (Windows) MVB – EMD bus @ 1 Mbps IEC 61375 / (optional)
USB / Ethernet 10/100/1000 Mbps / Profibus @12 Mbps
RS232 / RS422 + RS 485 / CAN bus / customized Housing
Interfaces
MVB – EMD bus @ 1 Mbps IEC 61375 /
Profibus @12 Mbps customized Termination
Nominal voltage 24 V DC (25 W max.)
-30° C ... +70° C Temperature
IP rating (IEC 60529) IP65
Temperature -30° C ... +70° C UIC 612-0 (following), EN 50155, EN 60068-2-1, IEC 61373,
Standards
EN 11170-3
Standards UIC 612-0, EN 50155, EN 60068-2-1, EN 61373, EN 11170-3
Page 7 I Electrics for rolling stock
FEATURES
■ Time and costs savings due to reduced ■ Standard master controller complemented by ■ In-house design and manufacture
engineering design time additional existing standardised modules ■ Field bus: Profinet, CAN, and others
■ Compact, rugged, durable ■ Compact, rugged, durable ■ Sensitive touch functions, RFID card reader,
■ Highly flexible, allowing last minute changes ■ Can be configured individually, allowing last automatic reset of the handle, and others
■ Setpoint device, wear and maintenance-free minute changes ■ Mechanically interacting function modules
■ Components in compliance with UIC 612 ■ Mechanically interacting function modules ■ Components in compliance with railway
■ Cost-effective due to use of standardized ■ Components in compliance with railway standards (UIC 612 and others)
components standards (UIC 612 and others)
upon request
SPECIFICATIONS
S337 S332 ... S338 SP60 Series
Settings,
To customer requirements To customer requirements To customer requirements
Dimensions, Design
Snap switches, encoders Snap switches, encoders Snap switches, encoders Switching elements
Output PWM, U, I, Graycode Output PWM, U, I, bus systems, Graycode Output PWM, U, I, bus systems, Graycode Encoder
Master/brake controller or preset speed
Master/brake controller Master/brake controller or preset speed controller, reverser, keylock switch, push button,
Operating elements
or preset speed controller controller, reverser, keylock switch, push button touch sensitive DSD*, RFID card reader,
others, customer specific
Ball, T handle, mushroom,
Ball, T handle, mushroom Ball, T handle, mushroom Handle styles
joystick, others, customized
> 1 million operations > 1 million operations > 1 million operations Mechanical endurance
-25° C ... +70° C -25° C ... +70° C -25° C ... +70° C Temperature
IEC 60077, EN 50155, DIN EN R60068, IEC 60077, EN 50155, DIN EN R60068, IEC 60077, EN 50155, DIN EN R60068,
Standards
DIN 0319 DIN 0319 DIN 0319
* DSD for driver's safety device (deadman's handle)
Electrics for rolling stock I Page 8
FEATURES
■ Dead-man handles and footswitches with change-over contact ■ Series JA222:
■ Rugged, long-lasting, reliable Signalling for intermittent automatic train-running control
■ Snap-action switch S804 or S814 and dead-man equipment
Multi-level adjustment of frequencies and volume
High electrical rating due to solid contact bridge
Contact material: hard silver or gold alloy ■ Series JA224 and JA226:
High resistance to shock and vibration Signalling of up to 9 and 10 different warning tones resp.
S814 featuring wiping, self-cleaning contacts Control inputs electrically isolated
Tone output prioritized or mixed
Multi-level adjustment of output volume
Download of the tones into the buzzer from
memory card
SPECIFICATIONS
Series S579 S293, ZL290 JA222 JA224A Series
Actuator Handle Foot switch 86 db(A)
Snap-action switch S804, S814 94 db(A) Sound level,
80 ... 100 dB(A)
104 db(A) distance 1 m
Configuration 1 x SPDT up to 2 x SPDT 110 db(A)
Rated insulation voltage Ui 400 V 340 Hz
9 different tones Pitch
550 Hz
Pollution degree PD3
24 ... 110 V DC 24 / 110 V DC Rated operating voltage Ue
Overvoltage category OV3
Conv. thermal current Ith 300 mA 500 mA Rated operating current Ie
10 A
IP rating (IEC 60529) IP67 IP20 IP20 IP rating (IEC 60529)
Mechanical endurance > 5 million operations > 1 million operations -25° C ... +70° C -25° C ... +60° C Temperature
Temperature -40° C ... +85° C JA222, JA222WD: EN 50155
Standards
Standard IEC 60077, VDE 0660 JA224A: EN 50128 SSAS=2, EN 50155, EN 50121-3-2
Page 9 I Electrics for rolling stock
Series F, P, L Series K
Toggle switches with snap-action switches Toggle switches
or cam-operated switching elements with subminiature switches S880
F, P and L Series toggle switches are available as 3 or 5 position contact The award-winning K Series toggle switch is the newest member of the
assemblies. The F and P series come fitted with snap-action switches, Schaltbau toggle switch family expanding the existing product range.
whereas the L Series sports cam-operated switching elements. K Series toggle switches can be equipped with up to 8 S880 Series sub-
The three toggle switch series are designed for use in switch panels and miniature snap-action switches that allow for 3 and 5 switch settings.
driving consoles of rail vehicles, but are also suitable for industrial applica- All applications as mentioned in the UIC 612 railway standard can be
tions, such as shipbuilding and vehicle construction. covered with them. To present driving cabs of locomotives and multiple-
unit trains in modern design will be no problem with them. The option of a
dimmable and consistent illumination of the K type switch makes separate
indication lights superfluous and also for effective night design.
FEATURES
■ Rugged, open design ■ Central switch mount with illuminated ring in 5 LED colours
■ 4 switching elements max. used as function indicator or for night design
F, P Series: snap-action switches ■ 8 switching elements max.
L Series: cam-operated switching elements ■ Lead wire seal option
■ Many different switch settings possible ■ Yellow ball handle for ETCS acknowledgement
■ L Series: suitable for direct switching of high currents ■ Cylinder handle for external warning horn of locomotives
■ Special handle styles available ■ Solid and fully sealed plastic housing
■ Protection against inadvertent operation available ■ Momentary and maintained operation compatible with F and P Series
■ Toggle switch can be lead tab sealed ■ Easy to mount
SPECIFICATIONS
F P L K Series
3 (2 x 30°) 5 (4 x 15°) 3 (2 x 35°) 5 (4 x 17,5°) 3 (2 x 35°) 5 (4 x 17,5°) 3 (2 x 32°) 5 (4 x 16°) Switching positions
S800, S826 S870 S800, S826 S800, S826 S005, S007, S008 S005, S007, S008 S880 Snap-action switches
1 ... 2 1 ... 4 1 ... 4 1 ... 8 # of switching elements
400 V 250 V 400 V 400 V 250 V Rated insulation voltage Ui
PD3 PD3 PD3 PD2 or PD3 Pollution degree
OV3 OV3 OV3 OV2 Overvoltage category
S005: 15 A / S007: 15 A, 60 A /
10 A 10 A 6A Conv. thermal current Ith
S008: 25 A, 60 A
> 300,000 operations > 300,000 operations > 100,000 operations > 500,000 operations Mechanical endurance
-20° C ... +70° C -20° C ... +70° C -20° C ... +70° C -40° C ... +85° C Temperature
UIC612,EN50155,EN50124-1,IEC60068-2-
IEC 60077, VDE 0660 IEC 60077, VDE 0660 IEC 60077, VDE 0660 1,IEC60068-2-1,IEC60068-2,IEC60068-2-38, Standards
IEC60529,IEC61373,DIN5510
Electrics for rolling stock I Page 10
FEATURES
■ Elegant design ■ Elegant design ■ Rugged switching device with aluminium die
■ Aluminium die-cast housing, rugged, long- ■ To be mounted flush into a wall cast housing and elegant design
lasting ■ Aluminium die-cast housing, rugged, long- ■ Supplied with or without lettering
■ Finish: semi-gloss varnish, resistant to acids and lasting ■ Available as rear-mounted versions without
chemicals ■ Finish: semi-gloss varnish, resistant to acids and visible fasteners
■ Handle can be lead sealed chemicals ■ or front-mounted versions with 4 visible M5
■ Optional automatic reset (spring return) ■ Handle can be lead sealed screws
■ 2 switching elements max. with gold or silver ■ Optional automatic reset (spring return) ■ Device can be sealed with a lead tab
contacts ■ 2 switching elements (S870) max. with gold or ■ Fitted with 2 switching elements max. (S826 or
■ Fitted with 2 switching elements max. (S870) silver contacts S870) with gold or silver plated contacts
with gold or silver plated contact ■ Standards: DIN EN 15327-1:2009
SPECIFICATIONS
Series NBS10 NBS30 NBS40
Snap-action switch S826 S826 S826 S870
Form Z SPDT, Form Z SPDT, Form Z SPDT,
Configuration SPDT
galvanically isolated galvanically isolated galvanically isolated
# of switching elements 2 2 2 2
Reset element Square/triangular spanner, none, customized Square/triangular spanner, none, customized Square/triangular spanner, none, customized
Degree of protection IP54 (user side) IP54 (user side) IP54 (user side)
Conv. thermal current Ith 10 A 10 A 10 A 6A
Mechanical endurance > 1,000 operations > 1,000 operations > 1,000 operations
Temperature -30° C ... +70° C -30° C ... +70° C -30° C ... +70° C
Standard IEC 60077 IEC 60077 IEC 60077
Page 11 I Electrics for rolling stock
FEATURES
■ Disconnecting and earthing device in accordance with the applicable safety ■ Disconnecting and earthing device in accordance with the applicable safety
regulations regulations
■ Suitable for all UIC voltages ■ Suitable for all UIC voltages
■ Insulation for operating voltages up to 5 kV DC max. ■ Insulation for operating voltages up to 5 kV DC max.
■ Double-break contacts ■ Load switching
■ Conv. thermal current 150 A ■ Lockable maintenance position
■ Lockable maintenance position ■ Forced disconnection of installation when opening the door
■ Forced disconnection of installation when opening the door or lid of the switchgear cabinet.
of the switchgear cabinet.
SPECIFICATIONS
ZH1500 ZH2020 Series
250 kW 120 kW Maximum breaking capacity
1x disconnecting contact / 1x earthing contact (optional 2x / 4x) 1x disconnecting contact / 1x earthing contact (optional 2x / 4x) # of contacts
150 A 120 A Conv. thermal current Ith
150 A @ 1.0 kV AC 16 2/3 Hz 120 A @ 1.0 kV AC 16 2/3 Hz Breaking capacity,
150 A @ 1.0 kV AC 50 Hz 120 A @ 1.0 kV AC 50 Hz resistive, T = 1 ms,
100 A @ 1.5 kV AC 50 Hz disconnecting contact
100 A @ 1.5 kV DC
50 A @ 3.0 ... 5,0 kV AC 50 Hz
50 A @ 3.0 ... 5,0 kV DC
PD3 PD3 Pollution degree
IP00 IP00 IP rating (IEC 60529)
> 1,000 operations (approx. 30 years) > 1,000 operations (approx. 30 years) Mechanical endurance
-40° C ... +85° C -40° C ... +85° C Temperature
EN 50155, EN 50124, EN 50153, UIC 550, UIC 552 EN 50155, EN 50124, EN 50153, UIC 550, UIC 552 Standards
Electrics for rolling stock I Page 12
FEATURES
■ Main contactor with positive opening operation and earthing ■ Identification of UIC 550 compliant voltages (1 kV 162/3 Hz / 1.5 kV 50 Hz /
function in one device 1.5 kV DC / 3 kV DC) and 3 kV 50 Hz
■ Can be padlocked for maintenance in disconnected position ■ Meets requirements for double insulation for 3 kV DC (UIC 550) according to
■ Allows parallel maintenance (also with multiple units) EN 50124-1:2001+A1
■ Application: ■ Customised setting of the device via PC –
Cut-in unit for HV inverters of railway vehicles same hardware for different configurations
Cut-in unit for inverters for fail-safe cutout ■ Application: Adapting the electrical configuration of RIC passenger coaches
of supply voltage to the detected supply voltage
SPECIFICATIONS
Series ► ZH2000-1030 ZH1114 Series
0 … 5,000 V AC, 162/3 … 50 Hz
Input voltage range 680 … 3,000 V AC, 162/3 … 50 Hz Input voltage range
0 … 5,000 V DC
acc. to UIC 550 900 … 3,000 V DC
680… 5,000 V AC, 162/3 … 50 Hz
Measurement range
900 … 5,000 V DC
Supply voltage Unom 24 / 110 V DC
Supply voltage Unom
24 / 36 / 110 V
acc. to UIC 550
Coil resistance 32 / 620 Ω ±5 % at 20° C
< 300 mA Rated operating current Ie
FEATURES
■ Off-load adjustment of electrical configurations to different networks, e.g. ■ Off-load adjustment of electrical configurations to different networks,
various train line voltages in accordance with UIC 550 e.g. various train line voltages in accordance with UIC 550
■ Suitable for all UIC voltages up to 5 kV DC max. ■ Suitable for all UIC voltages up to 5 kV DC
■ Inexpensive high-voltage switch for applications requiring high ■ Suitable for high conventional thermal
conventional thermal currents currents up to 50 A
■ Various control programmes available in accordance with the ■ Various control programmes available in accordance with the
requirements of the European railway companies requirements of the European railway companies
■ Simple adaptation of control programme to new requirements ■ Simple adaptation of control programme to new requirements
upon request
SPECIFICATIONS
SCO2, SCO3, SCO4 CO3, CO4 Series
600 … 3,000 V AC, 162/3 … 50 Hz 0 … 3,000 V AC, 162/3 … 50 Hz
Input voltage range
600 … 3,000 V DC (5.000 V DC to UIC550) 0 … 3,000 V DC (5 kV DC to UIC550)
SCO2: 2 position device
CO3: 3 position device
SCO3: 3 position device Positions
CO4: 4 position device
SCO4: 4 position device
1/2/3/5/8 2 / 4 / 6 / 8 / 10 Switching chambers
Supply voltage Unom
Manual: --- / Linear motor: 24 V / Gear motor: 110 V 24 / 36 / 110 V
acc. to UIC 550
85 ... 800 A 50 A Conv. thermal current Ith
EN 50124, EN 60077, EN 61373, UIC 550 EN 50124, EN 60077, EN 61373, UIC 550 Standards
Electrics for rolling stock I Page 14
FEATURES
■ Identification of UIC 550 compliant voltages (1 kV 162/3 Hz / 1.5 kV 50 Hz / ■ Suitable for load switching
1.5 kV DC / 3 kV DC) and 3 kV 50 Hz ■ 1 up to 3 switching positions
■ Meets requirements for reinforced insulation for 3 kV DC (UIC 550) accord- ■ Switch cylinder with snap-action switch
ing to EN 50124-1:2001+A1 ■ Snap-action switch for status indication
■ Low stand-by consumption ■ Door locker
■ Potentential-free switching output ■ Door locker, padlockable
■ Individual marking
SPECIFICATIONS
Series ZH842 H, ZH842 H2 TCMB TCMO Series
0 … 5,000 V AC, 162/3 … 50 Hz DC DC Type of voltage
Input voltage range
0 … 5,000 V DC
2x NO** 2x NO** Configuration main contacts
670 … 5,000 V AC, 162/3 … 50 Hz
Measuring range 4x SPDT-DB (S800/S826) 4x SPDT-DB (S800/S826) Configuration aux. contacts
610 … 5,000 V DC
750 V Nominal voltage Un
Supply voltage Unom
24 / 36 / 110 V
acc. to UIC 550 1,000 V Rated insulation voltage Ui
Rated operating current Ie < 3 mA from vehicle battery 800 A Conv. thermal current Ith
4.0 A max. @ 24/36 V DC * 2,500 A Rtd. short time withstand current Icw
Conv. thermal current Ith
0.2 A max. @ 110 V DC * Pollution degree/
PD2/OV3
IP rating (IEC 60529) IP20 Overvoltage category
IP40 (panel front), IP00 (rear) IP rating (IEC 60529)
Temperature -25° C ... +85° C
--- 24 ... 110 V DC, 230 V DC*** Supply voltage Us
Standards EN 50124, EN 50128, EN 50155
upon request 2 million. operations Mechanical endurance
* Relay contact, potential free ** Others upon request *** Manual override
Page 15 I Electrics for rolling stock
FEATURES
■ Manually operated ■ Electrically driven vacuum circuit breaker
■ High short-circuit current strength ■ Reduced life cycle costs: No pneumatics, no icing up of the device
■ Lockable operating and earthing position, safeguarded ■ Long life
with special locks ■ Almost maintenance-free, visual inspections will do
■ Indication of operating position ■ High availability and reliability: Thanks to the energy stored in
■ Mirror contacts with positive opening operation (aux. switches for a spring, the CVB never fails to switch ON even when battery is flat
mechanical indication of operating and earthing position) ■ Diagnostics function, optional: Monitoring/recording
■ Front plate fitted with additional test jacks for load testing before the state of operation
device is operated (optional) ■ Fail-safe
■ Mechanical locking of switchgear cabinet door (optional)
SPECIFICATIONS
Series ► SE CVB15 CVB25 ◄ Series
1kV 16 2/3 Hz, 1.5kV 50Hz 15 kV AC, 162/3 25 kV AC, 50 ... 60 Hz Nominal voltage Un
Voltage range
1.5kV DC, 3kV DC
17.5 kV AC 30 kV AC Rated operating voltage Ue
Sinus half wave 16 2/3 Hz: 30 kA 750 A 450 A Rated operating current Ie
Short-circuit current
1 sec sinus: 15 kA
Short-circuit
Earthing contacts 2 25 kA 20 kA
breaking capacity
Schaltbau GmbH
Hollerithstrasse 5
81829 Munich with compliments:
Germany