Sunteți pe pagina 1din 1

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

A B C D E F G H J

N
E
Door Schedule W
S
Sr. Door Size
Description Qty Remarks
No Type Width Height
1 D1 2100 2100 Double Leaf Wooden Frame Glazed Door 1

2 D2 1800 3000 Double Leaf Wooden Flush Door With Vision Panel 1 Access Controlled
7 7
3 D3 1500 2100 Double Leaf Wooden Flush Door With Vision Panel 1

4 D4 1200 2100 Single Leaf Wooden Frame Glazed Door 1

5 D6 900 2100 Single Leaf Wooden Flush Door With Vision Panel 3

6 D6a 900 2100 Single Leaf Wooden Flush Door With Vision Panel 2 Access Controlled

7 D7 900 2100 Single Leaf Wooden Flush Door 5

8 D7a 900 2100 Single Leaf Wooden Flush Door With Vision Panel 2

9 D8 900 2100 Single Leaf Disable Accessible Door 1 Key Plan


10 D9 750 2100 Single Leaf Wooden Flush Door 4

11 D10 2400 2100 Double Leaf Metal Door With Vision Panel 1 Access Controlled Notes :
12 D11 1200 2100 Single Leaf Wooden Flush Door With Vision Panel 1 Access Controlled 1) All Dimensions are in mm & Levels in mts.
2) Written dimensions to be followed drawing not to be measured.
13 FD2 1200 2100 Single Leaf Fire Rated Metal Flush Door With Vision Panel 3 2Hr Fire Rating + Access Controlled 3) Architecture Drawing shall be co-ordinated with Civil/Structure Drawings before
14 FD3 1200 2100 Single Leaf Fire Escape Metal Flush Door * commencing work. Any discripency shall be brought into Notice of Architect well in
advance.
15 FD4 1000 2100 Single Leaf Fire Escape Metal Flush Door 1 4) All Levels are finished levels unless otherwise noted.
Single Leaf Fire Rated Metal Flush Door With Vision Panel 2Hr Fire Rating + Access Controlled 5) Refer Electrical & Mechanical drawings for cutouts.
16 FD5 1200 2100 1

17 RS 2400 2700 MS Rolling Shutter 1


18 RS1 Existing Size High Speed Rolling Shutter 11 Abbreviations :
NGL : Natural Ground Level
FFL : Finished Floor Level
6 6
* : Numbers To Be Confirmed After Finalization Of Logistic Plan

Legend :
200mm Thk. ACC Block Wall
100mm Thk. ACC Block Wall

200mm Thk. Fire Rated ACC Block Wall


5 Existing Wall 5

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

4 4

REFERENCE DRAWINGS:-
Main Building Part Plans & Sections - 1 : 44130300/A01/2002/A0
Main Building Part Plans & Sections - 2 : 44130300/A01/2003/A1
Male Female Toilet Details - 1 : 44130300/A01/2006/A1
Male Female Toilet Details - 2 : 44130300/A01/2007/A1
Visitors' & External Toilet Details : 44130300/A01/2008/A1
Misc Details - 01 : 44130300/A01/2010/A1

* LADIES & GENTS TOILET REVISED


R4 * FIRE ESCAPE DOOR REVISED
* DOCK PLATFORM ADDED
* FENCE AREA REVISED

R2

3 3
* SERVER, UPS AND BATTERY RELOCATED
R2 * NON-AEROSOL AREA OMITTED.

R3 14.10.14 PS CS AN

R2 30.09.14 PS CS AN

R1 05.08.14 PS CS AN

R0 01.08.14 LM CS AN

Rev Date Description of Revisions Drawn Chkd Appr


Status

Client

Amazon Seller Services Pvt Ltd (ASSPL)


Survey -No. 696, Gundla
Pochampally, Medchel
Mandal - 500014
India
Consultant

2 2

Jacobs Engineering Pvt Ltd.

2nd, Floor, PTI Building, 16/7,


Miller Tank Bund Area, Off Thimmaiah Cross Road,
Vasanth Nagar, Bangalore-560052
Tel: +91.080. 49694700/701

Project

AMAZON FULFILLMENT CENTER


HYDERABAD

Drawing Title

MAIN BUILDING
GROUND FLOOR AND
FIRST FLOOR PLAN

1 1

Drawn PS Signed Date 01.08.14

Checked CS Signed Date 01.08.14

Approved AN Signed Date 01.08.14


Scale(s) Sheet
1:250
1 of 1
Drawing Number Revision

44130300/A01/2001/A0 R3
A B C D E
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT F G H J

S-ar putea să vă placă și