Sunteți pe pagina 1din 1

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO.

NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
NOTES:
1. THE ENCLOSURE SHALL BE IN ACCORDANCE WITH
150 25 MATERIAL SPECIFICATION 17-AMSS-008.

2. ENGRAVED BLACK LETTERS ON WHITE BACKGROUND


OR ENGRAVED WHITE LETTERS
ON BLACK BACKGROUND MAY BE USED.
12mm DIA. HOLE 50
3. DRIP PROOF CONSTRUCTION SHOWN IS PREFERRED
BUT NOT MANDATORY.
200 (TYP.)
4. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED
15 170 15 OTHERWISE.

126 22
C 5. FOR MOUNTING SUPPORT DETAILS REFER TO
STANDARD DRAWING AB-036540.

30
6. ALL BRASS HARDWARE SHALL BE 1/4 "-20 MINIMUM

15
SIZE.

7. ZINC CONTENT OF BRASS HARDWARE SHALL NOT


EXCEED 16%.

25
8. FOR NON-METALLIC BOXES ANY METAL HARDWARE
SHALL BE 300 SERIES STAINLESS STEEL.
#8 STAINLESS STEEL

50
9. IF THE ENCLOSURE IS NOT UL LISTED AND CERTIFIED
6
TO NEMA 4X, THE DESIGN OF THE ENCLOSURE MUST
MOUNTING HARDWARE
BE APPROVED IN WRITTING BY THE RSA FOR

25
CATHODIC PROTECTION MATERIALS.

9 TYP. (5 PLACES)

RETAINING CHAIN
FOR SOCKET CAP

12
CORROSION PROBE 8 7
8
SOCKET CAP ON
CATHODIC PROTECTION

100
ER SOIL CORROSION
A A
OFF

PROBE TEST STATION

250
200
150
PROBE P/L CONTINUOUS FULL
6 LENGTH HINGE

280
MATERIAL LIST
13 mm ENGRAVED DWG.
12 DESCRIPTION
CODE
LETTERS
4 mm ENGRAVED 1 ENCLOSURE: NEMA 4X; 200 x 250 x 110

SEE NOTE 2 2 PANEL: BLACK BAKELITE; 170 x 200 x 6


LETTERS CONDUIT HUB: ALUMINUM; WEATHER PROOF; 2",
3
WITH " " RING SEAL
SEE NOTE 2
4 PANEL: MOUNTING HARDWARE; SIZE AS REQUIRED
5
B 4 TYP. (4 PLACES) B 5 NAMEPLATE: LAMINATED BAKELITE; 150x100x3
NAMEPLATE MOUNTING HARDWARE: #8 STAINLESS
6
STEEL
7 ON/OFF TOGGLE SWITCH
2
8 STAINLESS STEEL BOLT 25mmx6mm
MANUFACTURER’S 9 STAINLESS STEEL BOLT 15mmx3mm
2
NAMEPLATE 10 CABLE #14AWG (2.5MM )

CORROSION PROBE; RCS 620HD-1-S20-K03005-50;


11
WITH 50 FT. LONG CABLE OR EQUAL
12 NAMEPLATE: LAMINATED BAKELITE; 100x20x3

15
3 REFERENCE DRAWINGS
1

MOUNTING SUPPORT DETAILS FOR AB-036540


12 (TYP.) JUNCTION BOXES

ELECTRICAL RESISTANCE SOIL CORROSION PROBE TEST STATION


200 x 250 x 110
:$$

(SHOWN WITHOUT DOOR)


OUTSIDE NAMEPLATE AND
:2003-10-07:A036145001V02

MOUNTING EARS DETAIL

200 200

170 170

22 126 22 22 126 22
:MHJ:75165

6
1

CP CONNECTION WIRE FROM


CORROSION PROBE CABLE 4 TYP. (4 PLACES)

DWG. RESPONSIBILITY:
CORROSION PROBE 1
CONNECTION CABLE 10
CATHODIC PROTECTION STD. COMMITTEE
INTERNAL WIRING TYP.
70

70
$$SARAMCO-DCC-STAMP$$:714120-1003-05

2
#8AWG (10MM ) SCALE:

CONNECTION WIRE
110

110
TO PIPELINE
REVISION VALIDATION

THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION


REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
6

6
7 DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
11 8 8
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
NONE
CORROSION PROBE
SOCKET
REV.NO. DATE REVISION DESCRIPTION

JOB ORDER/EWO NO.


THIS REVISION IS NOT TO BE USED FOR
CONSTRUCTION UNTIL CERTIFIED AND DATED

SECTION A-A SECTION B-B SAUDI ARABIAN OIL COMPANY


DRAWING TYPE

CATHODIC PROTECTION
TEST STATION-ER SOIL CORROSION PROBE
FOR BURIED PIPELINES
STD. DWG. SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

990 X AA-036067 001 00


Saudi Aramco 2615 ENG. (05/05)

Copyright©Saudi Aramco 2009. All rights reserved. CADD-05