Documente Academic
Documente Profesional
Documente Cultură
1
Part
Software licensed to
Job Title Ref
By Date01-Nov-18 Chd
Job Information
Engineer Checked Approved
Name:
Date: 01-Nov-18
Project ID
Project Name
Primary 1 1.4DL+1.4WL-CASE1
Primary 2 1.4DL+1.4WL-CASE-2
Plate Thickness
Prop Node A Node B Node C Node D Material
(cm) (cm) (cm) (cm)
1 1.200 1.200 1.200 1.200 STEEL
Print Time/Date: 12/12/2018 11:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 1 of 7
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref
By Date01-Nov-18 Chd
Materials
Mat Name E ν Density α
(kN/mm2) (kg/m3) (/°C)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6
1 1.4DL+1.4WL-CASE1 None
2 1.4DL+1.4WL-CASE-2 None
Load Generators
There is no data of this type.
Print Time/Date: 12/12/2018 11:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 2 of 7
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref
By Date01-Nov-18 Chd
2
2
2
2
2 0.175m
2
2
0.150m
2
2
2
2
2 2
2
2 2
2
2 2
2
2 2
2 2
2
2 2
2
2 2
2
2 2
2 2
2
2 2
2
2 2
2
2 2
2 2
2
2 2
2
2 2
2
2 2
2 2
2
2
2
2 2
2
2 2
2 2
2
2
2
0.105m 2
2 2
2
2
0.180m
2
2 2
2
2
2
2 2
2
0.180m
2
2
2
2
2
2 2
2
2 2
2
2 2
2 2
2
2 2
2
2
2 0.096m
2
2 2
2 2
2
2 2
2
0.150m
2
2
2
2 2
2 2
2
2 2
2
2 2
2
2 2
2
2
Y 2
2
X 2
2
2
Z 2
2 Load 1
2
2
Dimensions
Print Time/Date: 12/12/2018 11:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 3 of 7
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref
By Date01-Nov-18 Chd
Plate Thcikness
Print Time/Date: 12/12/2018 11:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 4 of 7
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref
By Date01-Nov-18 Chd
2
2
2
2
0.175m
2 2
0.150m
2 2
2 2
2 2
2 2
2
2 2
2
2 2
2
2 2
2 2
2
2 2
2
2
2
2
2
2
-2.450 kN
2 2
2
2 2
2
2 2
2
2 2
2 2
2
2 2 2 8.650 kN
2 2
2
2 2
2 2
2
2 2
2 2
2
2 2
2 2
2 0.105m
2 2 0.180m
2
2
2
2
2
2
-2.450 kN
2 2
2 2
2
2
0.180m
2 2
2 2
2 2
2
2 2 2 8.650 kN
2 2
2
2 2
2 2
2
2
2 2 0.096m
2 2
2
2 2
2 2
2
2 0.150m
2 2
2 2
2
2 2
2 2
2
2 2
2
2 2
2
Y 2 2
X 2 2
2
Z 2
2 2 Load 2 (SELF Y)
2
2
2
2
Print Time/Date: 12/12/2018 11:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 5 of 7
Job No Sheet No Rev
6
Part
Software licensed to
Job Title Ref
By Date01-Nov-18 Chd
Print Time/Date: 12/12/2018 11:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 6 of 7
Job No Sheet No Rev
7
Part
Software licensed to
Job Title Ref
By Date01-Nov-18 Chd
Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
Max FX 66 1:1.4DL+1.4WL-CASE1
8.682 -5.006 12.396 0.000 0.000 0.000
Min FX 66 2:1.4DL+1.4WL-CASE-2
-12.240 -4.906 -10.289 0.000 0.000 0.000
Max FY 73 1:1.4DL+1.4WL-CASE1
-8.682 10.069 -34.285 0.000 0.000 0.000
Min FY 66 1:1.4DL+1.4WL-CASE1
8.682 -5.006 12.396 0.000 0.000 0.000
Max FZ 73 2:1.4DL+1.4WL-CASE-2
-5.060 9.869 15.511 0.000 0.000 0.000
Min FZ 73 1:1.4DL+1.4WL-CASE1
-8.682 10.069 -34.285 0.000 0.000 0.000
Max MX 1 1:1.4DL+1.4WL-CASE1
0.000 0.000 0.049 0.000 0.000 0.000
Min MX 1 1:1.4DL+1.4WL-CASE1
0.000 0.000 0.049 0.000 0.000 0.000
Max MY 1 1:1.4DL+1.4WL-CASE1
0.000 0.000 0.049 0.000 0.000 0.000
Min MY 1 1:1.4DL+1.4WL-CASE1
0.000 0.000 0.049 0.000 0.000 0.000
Max MZ 1 1:1.4DL+1.4WL-CASE1
0.000 0.000 0.049 0.000 0.000 0.000
Min MZ 1 1:1.4DL+1.4WL-CASE1
0.000 0.000 0.049 0.000 0.000 0.000
Print Time/Date: 12/12/2018 11:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.70 Print Run 7 of 7
corner Bracket with one side anchor
Project
Reference code
Design office
Person in charge
Construction Office
Person in charge
Profile
No Profile has been applied
Selected Products
Anchor (name) m1tr
Approval ETA-12/0375
Size m1tr 16x130
Article code 3701613
Reference code
Design office
Person in charge
Construction Office
Person in charge
Anchor data
d Anchor/thread diameter: 16.0 mm tfix Thickness of fixture: 10.0 mm
dnom Outside diameter of anchor: 16.0 mm SW Spanner: 24.0 mm
d0 Drill hole diameter: 16.0 mm Tinst Max setting torque 120.0 Nm
h1 Depth of drilled hole: 115.0 mm
hnom Setting depth: 97.0 mm
hef Effective anchorage depth: 86.0 mm
df Diameter of clearance hole in fixture: 18.0 mm
PRODUCT
m1tr Throughbolt, stainless steel A4/316. European Technical Approval Option 1 for cracked and non-cracked concrete. Fire
resistance up to F120 is part of the approval. The anchor may also be used under seismic influence for performance category C1 +
C2. Small edge and spacing distances.
Stainless steel A4/316. Pre installation or through Fixing use in indoor and outdoor applications.
DESIGN CALCULATION
This calculation is based on specific values exclusively for the product above.
Any changes to the brand or physical conditions for design will require a recalculation of the anchor design.
ANCHOR PLATE
The design program assumes, in accordance with ETAG 001, Annex C, that the anchor plate does not deform as a result of applied
actions.
Thus, and in accordance with ETAG 001, Annex C, the anchor plate shall be sufficiently stiff and its design should be carried out
according to standards for steel structures ensuring elastic behaviour.
INSTALLATION
All conditions of the European Technical Approval (ETA) and Mungo technical publications shall be complied with in all detail. The
load values are valid only if the installation has been carried out correctly.
ADDITIONAL PROOFS
The designing and calculation of the anchorage should be carried out in accordance with annex C of ETAG001.
ATTENTION
The loads as well as the installation data can vary. Please consult our website www.mungo.swiss to download the newest version.
Reference code
Design office
Person in charge
Construction Office
Person in charge
Input Data
Tension Bending Reinforcement
NSd,Z 17.30 kN MSd,X 1.54 kN·m Diameter 11 mm
Shear MSd,Y 0.46 kN·m Distance rebars 200 mm
VSd,X 0.00 kN Torsion Distance stirrups 200 mm
VSd,Y 4.90 kN MSd,Z 0.00 kN·m Edge reinforcement No
Edges
CXp ∞ mm
CXn ∞ mm
CYp ∞ mm
CYn ∞ mm
Reference code
Design office
Person in charge
Construction Office
Person in charge
Tension force Shear force Shear force (x) Shear force (y)
Anchor
[kN] [kN] [kN] [kN]
1 20.59 2.45 0.00 2.45
2 17.19 2.45 0.00 2.45
2 17.19 29.31%
2 17.19 52.3%
Reference code
Design office
Person in charge
Construction Office
Person in charge
Group N0Rk,c Ac,N A0c,N hef scr,N ccr,N c-x c+x c-y c+y
Anchor
No. [kN] [mm²] [mm²] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1 [1, 2] 56.96 89,784 66,564 86 258 129 6,000 6,000 6,000 6,000
Group ψs,N ψre,N eN,x eN,y ψec,N NRk,c NRd,c Nsd βN,c
Anchor
No. [-] [-] [mm] [mm] [-] [kN] [kN] [kN] [%]
1 [1, 2] 1.000 1.000 4.0 0.0 0.970 74.49 49.66 37.78 76.1%
As smallest edge distance exceeds 1,2 x Ccr,sp and the thickness of concrete exceeds 2 x hef, it is assumed, acc. to Annex C
and TR029 5.2.2.6 a, that splitting failure will not occur.
Reference code
Design office
Person in charge
Construction Office
Person in charge
1 2
VRk,cp=k · NRk,c
Group N0Rk,c Ac,N A0c,N ψs,N ψre,N c-x c+x c-y c+y
Anchor
No. [kN] [mm ] 2
[mm2] [-] [-] [mm] [mm] [mm] [mm]
1 [1, 2] 56.96 89,784 66,564 1.000 1.000 6,000 6,000 6,000 6,000
Reference code
Design office
Person in charge
Construction Office
Person in charge
βN,s βN,p βN,comb βN,c βN,sp βV,s βV,cp βV,c βN,max,E βV,max,E βN,c,max,E βV,c,max,E βcombi,c,E βcombi,S,E
1 35.1% 62.6% 0.0% 76.1% 0.0% 6.2% 4.8% 0.0% 35.1% 6.2% 76.1% 4.8% 67.4% 12.7%
2 29.3% 52.3% 0.0% 76.1% 0.0% 6.2% 4.8% 0.0% 29.3% 6.2% 76.1% 4.8% 67.4% 9.0%
RESULT
Ok. The product meets the design criteria
REMARKS
The verification of anchor design cases covered by ETAG 001 or TR29 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be
found inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming
that the anchor plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate
shall be sufficient stiff. The user must verify this condition, since the base plate stiffness is not automatically calculated by the
software. The transfer of loads from anchors into base material must be verified in accordance with ETAG 001 Annex C or
TR29 Section 7. The design method is valid only for clearance hole in the fixture with a diameter not larger than the values
given in ETAG 001 Annex C or TR29 Table 4.1.
Reference code
Design office
Person in charge
Construction Office
Person in charge
IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and
complies with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and
safety regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the
manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any
errors or omissions are the responsibility of the user. The user must ensure that the most current version of the program is
installed by way of the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines,
without any guarantee of suitability for any specific application.