Sunteți pe pagina 1din 2

FIRE DETECTION SYSTEMS

MANUAL CALL POINTS

Manual Call Points DMX

Product Use Your advantages


The red manual call point is fully standard- Manual call points are used for the manual The manual call points are available as
ized within the European Union in accord- activation of fire alarms and the manual limit vale detectors, addressable loop
ance with the regulation EN 54 part 11. control of extinguishers. devices or with simple pushbutton config-
Structural form, colour and inscription Incipient fires are often detected quicker uration.
guarantee easy recognition. by people than by automatic fire detec- The housing is available in aluminium and
For the electrical activation of gas extin- tors. These devices are deactivated outside PC plastic. The various designs are available
guishers, manual call points in accordance of working hours (day/night-time mode). in diverse protection types. The mechanical
with EN 12094-3 are available in the follow- Alarm activation is carried out manually. design has been developed to meet
ing designs: yellow (RAL 1021) “MANUAL Some examples of where manual call demanding industrial requirements.
RELEASE Gas Extinguisher”, blue (RAL 5015) point are used are: Public buildings, senior Various designs are available:
“STOP SWITCH gas extinguisher” or green citizens’ homes, industrial premises, power
(RAL 6002) “ADDITIONAL DISCHARGE gas – For indoor and outdoor areas,
stations, airports, train stations, office
extinguisher”. The technical design has – Safe design for gas explosion protection,
blocks, events centres, etc.
been carried out in accordance with – Safe design for dust explosion protection,
EN 54 Part 11. All EU languages and non- Red manual call points have a symbol of
a burning house, thus ensuring easy recog- – Special manual call points resistant
regulated inscriptions are also available.
nition as a manual fire alarm and fire to atmospheres containing oils and
The red version (RAL 3001) is characterised department alert. chemicals.
with the 'House' symbol. All other inscrip-
The manual call points coloured yellow, Constant monitoring of individual
tions can also be supplied. Various designs
blue and green are used exclusively for the functions through loop technology.
are available for adaption to a wide range
of applications: manual control of extinguishing systems. Individual labelling is possible through a
The special functions are also allocated proprietary Minimax labelling system.
Various designs are available for use in a through colour and form, thus ensuring
wide range of situations through variations Red LED alarm display available on request.
easy recognition in the event that they
for protection types IP 42, 54, 65 and 66 in need to be used. The manual call points are Extensive product expertise due to many
accordance with EN 60529, for explosive also equipped with a written sign in order years of use in 6 continents (including the
areas, designed for category 2G, 3G and 3D to avoid erroneous use. Antarctic).
according to directive 94/9/EC (ATEX), in
addition to special manual call points for
atmospheres containing oil.
Manual Call Points
DMX 3000 DMX 3000 variabel DMX 3100 2GRU
Standard conventional limit value detector in accord- Includes all DMX 3000 series manual call points that Manual call point from the DMX 3100 series with
ance with EN 54 part 11. Protection type IP 42 can be deviate from standard devices. In this category, we connections for two limit detection lines. Identical
extended to IP 54 by using weatherproof housing. can implement special customer requirements. functions to DMX 3000 2GRU.
The manual call point is operated by breaking the DMX 3000 Ex DMX 3100 UCO
glass and pressing the activation button. Conventional manual call point of the DMX 3000 Manual call point limit value detector for universal
DMX 3000 SF series, for use in explosive areas in zones 1, 2 and 22 use with any fire detection control panel. The manual
Conventional manual call point for the DMX 3000 for non-conductive dust in accordance with directive call point can be designed for special mounting upon
series, but with a silicone-free design. Particularly 94/9/EC (ATEX). Ex manual call points may only be client request.
suited for painting and clean-room technology. used with a safety barrier. DMX 3100 SUX 95
DMX 3000 2GRU DMX 3000 Ex variabel Manual call point from the DMX 3100 series with
Conventional manual call point of the DMX 3000 The same design as DMX 3000 Ex, but with the added single addressable loop functionality in the Apollo
series with connections for two limit detection lines advantage of implementing individual customer XP95 loop system. The address is programmable via
for activating alarms on two lines. Used primarily in requirements in accordance with ATEX directives. coding switches located on the printed circuit board.
critical EMC areas. DMX 95 The manual call point has an integrated isolator.
DMX 3000 LED Manual call point from the DMX 3000 series with DMX KAC Loop
This manual call point includes a red LED alarm. After single addressable loop functionality in the Apollo Manual call point with the smallest technical design
the alarm has been activated by pushing the acti- XP95 loop system. The address is programmable via in accordance with EN 54 part 11 with single address-
vation button, the LED will remain illuminated until coding switches located on the printed circuit board. able loop functionality in the Apollo XP95 Loop
the pushbutton is unlocked. The manual call point is fitted with isolators. system. The address is programmable via coding
DMX 3000 CN/ LED DMX 3100 switches located on the printed circuit board.
This manual call button is the equivalent of DMX 3000 Manual call point with the following differences Isolators are not integrated.
or DMX 3000 LED. It has been certified by Chinese CCC compared to the DMX 3000 series: Primarily for use DMX KAC Limit Value Detector
authorisation. outdoors, in extreme climates and severe industrial Manual call point limit value detector with the smallest
atmospheres. mechanical design in accordance with EN 54 part 11.
The mechanical design is identical to DMX KAC Loop.

Technical data

Type Special features Area of application Operating Dimensions Protection Material Approvals Colors
Temperature
Range in ºC mm

DMX 3000 Conventional 2-wire line For indoor areas, also with weather- –30 to +70 125 x 125 x 32,5 IP 42/54 Metal VdS, FM, Russia, China, red, yellow,
Switzerland, Austria,
proof housing for outdoor areas Slovakia, Hungary blue, green

DMX 3000 SF Conventional 2-wire line For indoor areas, also with weather- –30 to +70 125 x 125 x 32,5 IP 42/54 Metal VdS, FM, Russia, China, red, yellow,
Switzerland, Austria,
silicone-free proof housing for outdoor areas Slovakia, Hungary blue, green

DMX 3000 2GRU Conventional 2-wire line For indoor areas, also with weather- –30 to +70 125 x 125 x 32,5 IP 42/54 Metal VdS red, yellow,
2 contacts for alarm signal proof housing for outdoor areas blue, green
VdS, Russia, China,
DMX 3000 LED Conventional 2-wire line For indoor areas, also with weather- –30 to +70 125 x 125 x 32,5 IP 42/54 Metal Switzerland, Austria,
red, yellow,
with red LED alarm proof housing for outdoor areas Slovakia, Hungary blue, green

DMX3000 CN and Conventional 2-wire line For indoor areas, also with weather- –30 to +70 125 x 125 x 32,5 IP 42/54 Metal China red, yellow,
DMX3000 CN LED with red LED alarm for proof housing for outdoor areas blue, green
the Chinese market
VdS, Russia, China,
DMX 3000 variable Conventional 2-wire line For indoor areas, also with weather- –30 to +70 125 x 125 x 32,5 IP 42/54 Metal Switzerland, Austria,
red, yellow,
Custom designed proof housing for outdoor areas Slovakia, Hungary blue, green

DMX 3000 Ex Conventional 2-wire line For indoor areas, also with weather- –25 to +70 125 x 125 x 32,5 IP 42/54 Metal VdS, Russia red, yellow,
with limit value technology proof housing for outdoor areas blue, green
For ex zones 1, 2 and 22 with
non-conductive dusts

DMX 3000 Ex variable Conventional 2-wire line For indoor areas, also with weather- –25 to +70 135 x 127 x 50 IP 42/54 Metal VdS, Russia red, yellow,
with limit value technology proof housing for outdoor areas blue, green
Custom designed For ex zones 1, 2 and 22 with
non-conductive dusts

DMX 95 Analogue addressable For indoor areas, also with weather- –20 to +70 125 x 125 x 32,5 IP 42/54 Metal VdS, Russia red, yellow,
Manual call point proof housing for outdoor areas green

DMX 3100 Conventional 2-wire line For outdoor areas –35 to +60 135 x 161 x 61 IP 66 PC VdS in approval, red, yellow,
Incl. cable fittings Russia blue, green

DMX 3001 2GRU Conventional 2-wire line For outdoor areas –35 to +60 135 x 161 x 61 IP 66 PC VdS in approval, yellow
2 contacts for alarm signal Incl. cable fittings Russia

DMX 3100 ZPD Conventional 2-wire line For outdoor areas –35 to +60 135 x 161 x 61 IP 66 PC VdS in approval, red, yellow
Incl. cable fittings Russia

DMX3100 UCO Conventional 2-wire line For outdoor areas –35 to +60 135 x 161 x 61 IP 66 PC VdS in approval, red, yellow,
Printed in Germany

for universal use Incl. cable fittings Russia blue, green

DMX 3100 SUX 95 analogue addressable man- , For outdoor areas –20 to +60 135 x 161 x 61 IP 66 PC VdS in approval, red, yellow,
ual call point with isolator Incl. cable fittings Russia green

DMX 3100 SUX 50 MX Loop manual call point For outdoor areas –20 to +60 135 x 161 x 61 IP 66 PC Russia red
Incl. cable fittings
PB56Fe_02/ 11.04/3/09.08/HA

DMX KAC Loop XP 95 manual call point, For indoor areas –20 to +60 87 x 87 x 52 IP 53 Plastic Russia, Czech Republic red, yellow,
KAC green

DMX KAC Loop XP 95 manual call point, For outdoor areas –20 to +60 87 x 87 x 52 IP 65 Plastic LPCB red, yellow,
KAC KAC (IP65) green

DMX KAC Conventional 2-wire line, For indoor areas –20 to +60 87 x 87 x 52 IP 53 Plastic LPCB red, yellow,
Limit value detector KAC blue, green

Languages available: German, English, French, Spanish, Arabic. Other languages upon request. Subject to technical modifications / approval version changes

Minimax GmbH & Co. KG


# Nr. S 89201

Industriestrasse 10/12 VdS


23840 Bad Oldesloe
Certified acc. to
Germany ISO 9001

Phone: +49 4531 803-0


Fax: +49 4531 803-248
E-mail: info@minimax.de
www.minimax.de

S-ar putea să vă placă și