Description
Typical application
Standard current ratings and typical internal resistance values Technical data
Current Internal resistance values (Ω) per pole For further details please see chapter: Technical Information
rating (A) Voltage rating 3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
F1 F2 K1, M1, T1 K2, M2, T2
(higher DC ratings to special order)
0,02 1 493 953 2 669 2 457 Current ratings 0.02...50 A DC
0,05 276 152 452 376 0.02...30 A AC
Auxiliary circuit 6 A, AC 240 V;
0,1 58 37 100 94 3 A, DC 28 V
0,25 8,2 6,0 15,5 14,7 1 A, DC 65 V;
0.5 A, DC 80 V
0,5 2,3 1,47 3,9 3,2 Typical life
0,75 0,98 0,63 1,65 1,56 3 AC 415 V, AC 240 V:
2015/16 www.e-t-a.de 4 - 13
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
}
1 single pole protected DC 80 V 0.05 A…30 A
UL UL 489A
2 two pole protected magnetic and (1 + 2 pole)
3 three pole protected hydraulic magnetic delayed
Panel hardware CSA C22.2 No AC 250 V 0.02 A…30 A
0 without panel hardware 235 DC 80 V 0.02 A…30 A
Terminal design (main contact) CQC GB 17701 AC 240/415 V 0.02 A…30 A
K4 screw terminals M5 recommended for IN > 20 A AC 240 V 0.02 A…30 A
P1 blade terminals A6.3-0.8 mm (QC.250) (≤ 35 A) DC 80 V 0.02 A…50 A
Characteristic curve *)
QPL MIL-C-55629 AC 240 V 1 A…30 A (8340-F410)
Characteristic curve, instantaneous:
Sweden DC 50 V 1 A…30 A (8340-410)
F1 DC AC 240 V 1 A…30 A (8340-F420)
Defence
F2 AC 60/50 Hz Material AC 240 / 415 V 1 A…30 A (8340-F430)
Short delay: Admin.
K1 DC
K2 AC
Medium delay: Internal connection diagrams
M1 DC
M2 AC 60/50 Hz
Long delay: 1-pole protected multipole
T1 DC magnetic
line 1 11(C)
T2 AC 60/50 Hz
line 1 11(C) unit 1
Actuator colour/design
A black, long toggle
4 K black, short toggle
Z black, without toggle, with slot (only 1-pole) 12(NC) 14(NO) I>
12(NC) 14(NO)
*) Other
characteristic curves upon request (e.g. pulse delayed, for high
inrush currents or capacitive loads)
Preferred types
8340-F410-P1K1-KNH142- x x x x x x x x x
8340-F410-P1M1-KNH0- x x x x x x x x x
8340-F410-P1M1-KNH142- x x x x x x x x x
8340-F410-K4K1-KNH0- x x x x
8340-F410-K4K1-KNH142- x x x x
8340-F410-K4M1-KNH0- x x x x
8340-F410-K4M1-KNH142- x x x x
4 - 14 www.e-t-a.de 2015/16
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Dimensions
14.4
.567
5.5
.130
3.3
.217
.118
.689
17.5
ON OFF
3
ON OFF
41.2
1.62
41.2
1.62
1 4 3 2
1 4 3 2
50.8 19 50.8
2.00 .748 2.00
66
Ø15
.591
2.60
26.7 4.3
.748
19
1.05 .169
42.2
1.66
27.4
Actuator: short toggle 1.08
30°
.339
30°
8.6
.220
5.6
1 4 3 2
Actuator: without toggle, with slot Actuator: without toggle, with slot
ON 30° 30° OFF
ON
30° 30°
OFF 4
.130
3.3
1 4 3 2
.208
5.3
Cut-out dimensions
max. panel thickness: 2 ± 0.1 mm or 4 ± 0.15 mm
(snap-fit)
19
mounting thread M3
.748 or 6-32 UNC-2B 57.6±0.2
mounting depth 2.27±.008
max. 4.5 mm/.177 in. 38.4±0.2
Cut-out dimensions tightening torque max. 0.33 Nm
1.51±.008
max. panel thickness: 3 mm 19.2±0.2
3.5±0.1 (M3) .756±.008
+0.1
4 -0.15 (6-32UNC)
.138±.004 (M3)
.630±.004
Ø16±0.12
+.004
2.18±.008
.157-.006 (6-32UNC)
55.4±0.2
1.05±.004
26.7±0.1
1.66±.004
42.2±0.1
2015/16 www.e-t-a.de 4 - 15
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Actuator long 1
1 4 3 2
.382
0
9.7
0
16 A 16 A 16 A
6 38.8 9.4
Actuator short .236 1.53 .370
OFF
OFF
0
P1 blade terminals
0
16 A
16 A
1 4 3 2
number of poles: 1 - 3
.378
9.6
Configuration: F9
Actuator long 6 38.8 blade terminals
.236 1.53 DIN 46244-A6.3-0.8
Auxiliary contacts
16 A 16 A 16 A 16 A 16 A 16 A
4 number of poles: 1
Configuration: F4 / F9
1
11 14 12
2
14.5
.571
Actuator: Z (black, without toggle, with slot)
.197
5
17.9 10.2
.705 .401
OFF OFF
5.1 blade terminals
.200 DIN 46244-A2.8-0.5
16 A
16 A
Installation drawing
34
12
Terminal design K Terminal design P
blow out outlet CBE
.039
.039
1
operating area
5
terminal
(reinforced insulation) mounting area
area 6
2
4
.276
.079
.079
7
.157
2
.039
1
1.18
1.18
30
30
.276
7
8 8
.315 29 .315 29
42 42
1.65 1.14 1.65 1.14
blow out area
(minuaturable on request)
4 - 16 www.e-t-a.de 2015/16
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
1000 1000
100 100
10 10
1 1
0,1 0,1
0,01 0,01
0,001 0,001
0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 11 12
… times rated current … times rated current
1000 1000
100 100
Trip time in seconds
1 1
0,1 0,1
0,01 0,01
4
0,001 0,001
0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 11 12
… times rated current … times rated current
1000 1000
100 100
Trip time in seconds
Trip time in seconds
10 10
1 1
0,1 0,1
0,01 0,01
0,001 0,001
0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 11 12
… times rated current … times rated current
1000 1000
100 100
Trip time in seconds
10 10
1 1
0,1 0,1
0,01 0,01
0,001 0,001
0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 11 12
… times rated current … times rated current
N.B. All curves will only be maintained if the escutcheon is mounted on a vertical surface.
Ambient temperature or mounting side-by-side does not influence the trip curve, derating is not required.
The breakers may trip in the event of current peaks < 0.003 sec. For these applications we
offer a mechanical pulse delay – please enquire.
Other characteristic curves upon request (e.g. pulse delayed, for high inrush currents or capacitive loads).
2015/16 www.e-t-a.de 4 - 17
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Accessories
1.670±.006
42.4±0.15
Ø1
7.
Ø3 1 [.6
73
30.7
1.20
Ø4 .5
15.7
.618
1 ]
[.1 [.13
18 .039 57 8]
]- -M
.708 6-
32 3
UN
C
Ø
3.5
2 pole for 8340-F4 [.1
38 mounting holes
X 211 118 01 ]-
M 40.15±0.15
40 3
2 1.58±.006
1.57
.079
1.670±.006
42.4±0.15
37.9
1.49
19.2±0.1
19 .756±.004
0 6
.748
90 ±.0
2.2
5
.087
Ø2
4 2
.079
59.15±0.15
2.33±.006
.618
15.7
37.9
1.49
15
0.
5±
.1 .006
25 0±
1.670±.006
Ø3
Ø .99
42.4±0.15
19 57
.5
2.24 Ø
.748
[.13
2.2 37.8±0.15
.087 1.49±.006
8] -
M3
40
1.6 x 45°
.063x45°
1.57
3.3
21
Ø 3.5
Ø .138
17.7
.697
50.5
1.99
4 - 18 www.e-t-a.de 2015/16