Sunteți pe pagina 1din 6

Price Schedule for Goods (Form PG3-3A)

Invitation for CAAB/CE/W- Date:


Tender No: 478(E/M)(Cap.Exp)(Part-99) /2006
Tender 45.2/2016-2017 (Jessore) Package [enter description as specified in Section 6]
Package No: Description:
Tender Lot No: Lot Description: Providing of 1x6mm2 primary cable for Runway
lighting system i/c E/M works (S. H:-
Upgradation/Replacement of Runway light
fittings i/c related works at Jessore Airport)

A: PRICE OF GOODS(Including Spare Parts, if any) AND DELIVERY SCHEDULE


1 2 3 4 5 6 7
Item Description Of Item Country Unit of Qty Unit price Total price
No. of Measurem Of units (col. 4  5)
Origin ent Required

(Note1)
01. Providing & fitting of High intensity R/W edge light fitting
Elevated type (EHB/REDL-150-01 or equivalent, 200W 6.6A
(White) Except lamp with base plate as per FAA/ICAO
standard & as per direction of the Engineer in charge. Each 74 Nos
02. Supply of Low intensity Dumble light fitting with base with
plate Elevated type (IDM-5848 or YY-35) 45W 6.6 Amps
(Blue) except lamp as per FAA/ICAO standard & as per
direction of the Engineer in charge. Each 18 Nos
03. Providing & laying of Airfield Ground lighting system primary
cable 1x6sqmm stranded copper conductor XLPE insulted
5KV Grade copper screen PVC or PE outer sheeted as per
ICAO/FAA standard (FAA L 824) as approved by the Engineer
in charge. Made In EU countries USA/Japan/ Korea/ Properly
laying as per direction of the Engineer in charge. P/mtr 13957 Mtr
04. Providing & laying of 2x4sqmm flexible type secondary
Airfield Ground lighting cable Rubber insulated & sheathed as
per ICAO/FAA stranded (FAA L 824) as approved by the
Engineer in charge. Made in EU contries/USA/ Japan/Korea.
Properly laying as per direction of the Engineer in charge. P/mtr 968 Mtr
05. Providing & Installation of 200 watts 6.6Amps, 5KV, Rubber
Capsulated Isolating Transformer, 3-way working capacity
voltage suitable for High intensity Air field lighting system
made of European Countries or its equivalent as per sample &
as per FAA/ICAO standard complete as required & as per
direction of the Engineer in charge. Each 86 Nos
1 2 3 4 5 6 7 8 9
06. Providing & Installation of Primary
connector kit for Primary cable of
conductor size (KD-500) 1 x6sqmm 5KV
in R/W lighting system. Made in EEU
countries USA/Japan/Korea and as per
FAA/ICAO standard. P/kit 172 Kits
07. Providing & Installation of Secondary
connector kit for Secondary cable of
conductor size (KD-501) 1 x4sqmm for
R/W lighting system. Made in EEU
countries USA/Japan /Korea and as per
FAA/ICAO standard. P/kit 86 Kits
08. Providing & Installation of 200 watts 6.6
Amps Tungesten halogen lamp PK-30d
Base suitable for Runway light fittings as
per FAA/ICAO Standard and by the
direction of the Engineer in charge. Each 86 Nos
09. Supply of following capacity constant
current Regulator (CCR) Air cooled
Thyristor type Controlled by
microprocessor model MICRO-100/CCR-
2 Digital type single output 6.6A input
415V 50Hz. 7-brightness levels with
indicator local etc bolts, output lighting
protection 2 stage earth to the detection
complete etc as required and as per
sample and approved by the Engineer in
charge. The Technically specification of
the aforesaid CCR should be complied to
FAA/ICAO standard foreign made. The
CCR should be installed in circuit &
testing the same at 8Hrs. complete as
required.
a) 20 KW Constant Current regulator Each 2 Nos
10. Installation of the above supplied
following constant current regulator
(CCR) and D-37 connector with control
cable on the floor with required angle,
channel, washer etc in/c making electrical
and control connection and finally
checking testing and commissioning the
same as load complete as per manufacture
guide line as required.
a) 5, 10 & 20 KW (above supplied)
CCR for Runway lighting system. Each 1 No
11. Earthing the electrical installation with 40
mm. (1.5") dia G.I. pipe (Earth electrode)
having 6.35 mm. dia hole across the pipe
at 305 mm. interval securely bonded with
2 nos.of No2 SWG HDBC earth leads
with its protection by 20 mm. (3/4") dia
G.I. pipe up-to plinth level run at a depth
of 609.6 mm. (2 ft.) below G.L.up-to main
board to be earthed including necessary
connecting copper sockets, bolts, nuts,
etc. complete for maintaining earth
resistance within 1 ohm.
a) Depth of bottom of main electrode at
12954 mm. (42.5 ft) from GL & length of
electrode 12192 mm. (40 ft). P/set 8 Sets
1 2 3 4 5 6 7 8 9
12. Construction of Earthing inspection pit inside
measurement 600 mm x 600 mm with 250
mm thick brick in cement morter (1:4) with
100mm thick RCC top slab (1:2:4) with 1%
re-inforcement 450 mm dia water sealed CI
man-hole cover with locking arrangement
including necessary earth works, site filling
and one brick flat soling 75 mm thick (1:3:6)
base concrete for making inlet channel &
12mm thick (1:2) cement plaster with neat
finishing etc.all complete up to a depth of .75
meter. P/set 8 Sets
13. Construction of masonry Transformer pit with
250mm thick brick work in cement mortar
(1:4) including necessary earth works side
filling and one layer brick flat soling 75mm
thick (1:3:6) base concrete for making invert
channel and 12mm thick (1:2) cement plaster
with neat finishing etc. all complete up to
depth of 700mm approved and accepted by
the Engineer in charge.
Clear 600x600mm and depth 750 to 900 mm
average 825mm for single 300 mm dia R.C.C
pipes and 375mm and 400mm PVC pipe. Each 86 Nos
14. Providing & laying of 50mm dia HDPE pipe
for drawing of primary/secondary cable i/c
necessary cutting of the surface/ground and
its back to remote original finish. P/mtr 286 Mtr
15. Providing & laying standard copper conductor
(equivalent & cross section to 12 SWG) earth
continuity conductor along with the Primary
cable for lighting protection and for 13957
grounding of the hardware. P/mtr Mtr
16. Providing & laying of the following
additional PVC insulated & sheathed cable
(NYY) / XLPE insulated & PVC sheathed
cable (2XY) with PVC insulated green/white
coloured ECC wire (BYA) connecting at both
ends, through PVC pipe with necessary
accessories in a common trench In kutcha
ground/ pucca floor. All electrical contacts
shall be of brass/ copper connected through
connector or soldering (no twisting shall be
allowed) and cables shall be manufactured
and tested according to relevant IEC/
BDS/BS/VDE standards and as per detailed
specification mentioned in Annexure-A. The
work shall be carried out as per
direction/approval/acceptance of the
Engineer.
Cables manufactured by Paradise/BRB or any
other company(s) having valid test certificates
from Internationally accredited Laboratory
accepted/ approved by the Engineer.
a) IC-4 x 35 sq.mm (NYY/2XY) with 25
sq.mm (BYA) ECC wire through PVC pipe of
minimum inner dia 65 mm having wall
thickness of 2.5 mm. P/mtr 43 Mtr
1 2 3 4 5 6 7 8 9
17. Supply & installation of 415V, 3
Phase, 50 Hz. Indoor type Feeder panel
board (Size= 4.5’ x 6’ x 1.75’)/Low
tension switchgear of the Following
specification complete with busbar,
voltmeter & ammeter, of a adequite
rating both with selector switch,
Indicator lamp for On/OFF and
following components (including
busbar) component manufactured
SWITZERLAND/ FRANCE/JAPAN/
ITALY or its equivalent approved by
the Engineer in chage. locally factory
assembled in 16 SWG sheet steel clad
dust & verming powder coated painted
cabinet (MCCB’s in LT Panel must
comply NEMA/VDE/JIS/BSS
standard.
Incoming :
1 Set 415V, 500A TP + NL Busbar.
1 x 300A TPMCCB (35KA)
3 x 415V, 300/5 CT & Ammeter
(Digital)
3 x 415V/220V-0-500V range Volt
meter (Digital)
3 x Indicator Lamp.
Outgoing:
3 x 100 A TPMCCB (10KA)
3 x 80A TPMCCB (10 KA)
3 x 63A TPMCCB (6 KA)
5 x 32 A SPMCB Each 1 No
18. Supply of Biderection high intensity
elevated type Threshold light fitting
with base (IDM-5848 or equivalent
except lamp as per FAA/ICAO
standard & as per direction of the
Engineer in charge. Each 12 Nos
1 2 3 4 5 6 7 8 9
19. Testing & Commissioning of
complete Runway Edge light fitting
& CCR unit, with Complete as
required and as per direction
direction of the Engineer in charge &
latest ICAO standard. P/job 1 Job
Total Tk.

Note 1: Price shall include all customs duties, VAT and other taxes already paid or payable if Contract is awarded and
Shall be delivered price in final destination or at point of delivery.

Note 2: The Tenderer will complete these columns as appropriate following the details specified in Section 6: Schedule of Requirements

Signature:
Name:
In the capacity of:
Duly authorised to sign the Tender for and on behalf of the Tenderer

S-ar putea să vă placă și