Sunteți pe pagina 1din 28

Workshop 8

Explosive Demolition of Concrete

Introduction to ANSYS AUTODYN

1 © 2011 ANSYS, Inc. March 9, 2012
Workshop Goal and Procedure 

Goal: 
Model the Explosive Demolition of a 
Concrete Slab

Procedure:
Start AUTODYN standalone
Set up the problem using 2D Axial 
Symmetry
Model the Concrete in Lagrange
Model the Explosive in Euler
Add Euler/Lagrange Interactions
Solve the problem

2 © 2011 ANSYS, Inc. March 9, 2012
Quick Instructions

• Start AUTODYN standalone and create a 2D axially symmetric 
model with the default units (mm,mg,ms) with the ident
“demolition”
3 © 2011 ANSYS, Inc. March 9, 2012
Quick Instructions

Load in Air, Conc‐35Mpa and TNT from the material library
Modify the failure model of Conc‐35Mpa to be principal 
stress with a tensile failure of 5000kPa and a crack 
softening fracture energy of 100 J/m2
Create an initial condition called ATMOS for air with an 
internal energy of 2.068x105
Create a Flow Out Euler boundary condition with equal 
preference for flow out materials
Set up two parts as shown in the following figures

4 © 2011 ANSYS, Inc. March 9, 2012
Quick Instructions
Lagrange part: TARGET
(0.0,1000.0) (500.0,1000.0)

Conc 35MPa
100 elements

(0.0,0.0) (500.0,0.0)
50 elements
5 © 2011 ANSYS, Inc. March 9, 2012
Quick Instructions
2D multi material Euler part: SPACE

Flow out boundary


140 elements
(-800.0,1000.0) (600.0,1000.0)

Initial condition
ATMOS
100 elements
Flow out
boundary Flow out
boundary
200

200
(-800.0,0.0) (600.0,0.0)
(-200.0,0.0)

TNT

6 © 2011 ANSYS, Inc. March 9, 2012
Quick Instructions

Create a detonation point at (‐200.0,0.0)
Set up interactions
• Use the external gap contact for Lagrange/Lagrange 
calculations and calculate the gap size (should equal 1.0)
• Use Automatic for the Euler/Lagrange coupling
Set the wrap up criteria to be a time of 0.3 ms
Output the file every 0.01 ms
Run the simulation and create some GIF and GFA animations

7 © 2011 ANSYS, Inc. March 9, 2012
Step 1 – Start AUTODYN standalone
1. Start AUTODYN standalone (Double click autodyn.exe)

8 © 2011 ANSYS, Inc. March 9, 2012
Step 2 ‐ Initiate a new project
2.a  Start a new project

2.b  Browse to select a project 
Folder 

2.c  Enter an Ident
“explosive_demolition” and 
a Heading

2.d  Select 2D Axial Symmetry

2.e  Keep the default set of units 
(recommended for 
accuracy)

2.f  Accept the data
9 © 2011 ANSYS, Inc. March 9, 2012
Step 3 – Retrieve material data from library
3.a  Load material data

3.b  Select the following 
materials from the 
library:

AIR

CONC‐35MPA

TNT

3.c  Accept the data

<control>+<click> to select all three materials

10 © 2011 ANSYS, Inc. March 9, 2012
Step 4 – Improve the Concrete Model
Improve the Concrete model by 
adding tensile failure with 
Crack Softening
4.a  Select CONC‐35MPA

4.b  Select Modify

4.c  Select Principal Stress for 
Tensile Failure and enter 
“5.0e3” for the Principal 
Tensile Failure Stress
4.d  Turn on Crack Softening and 
enter “100.0” for the Fracture 
Energy
4.e  Accept the data

11 © 2011 ANSYS, Inc. March 9, 2012
Step 5 – Create Initial Condition Set for Air
5.a  Select Init. Cond. On Navigation Bar

5.b  Select New in the dialog panel

5.c Enter “Atmos” for the Initial Condition 
Set Name

5.d  Select Include Material

5.e  Choose Air for the material

5.f  Enter “2.068e5” for the Internal 
Energy (this initializes the air to a 
pressure of 1 atmosphere)

5.g  Accept the data
12 © 2011 ANSYS, Inc. March 9, 2012
Step 6 – Define Outflow Boundary Condition
6.a  Select Boundaries on the Navigation 
Bar

6.b  Select New to define a new boundary 
condition

6.c  Enter the Boundary Name “Outlow”

6.d  Select Flow_out for the Type and Flow 
out (Euler) for the Sub option

6.e  Select ALL EQUAL for the Preferred 
Material (HE and Air are given equal 
preference for transport)

6.f  Accept the data
13 © 2011 ANSYS, Inc. March 9, 2012
Step 7 – Create a Lagrange Part for the Structure
7.c Enter “Structure” 
for the Part Name

7.d  Select the 
Lagrange Solver

7.e  Keep Part wizard

7.a Select 7.f  Move to the next 


Parts On step
Navigation
Bar

7.b Select
New in the
dialog panel
14 © 2011 ANSYS, Inc. March 9, 2012
Step 8 – Define Geometry for Structure Part
8.a  Select the Box Predef (default)

8.b  Enter (0.0, 0.0) for the box 
origin and (500.0,1000.0) for 
the box dimensions

8.c  Move to the next step

15 © 2011 ANSYS, Inc. March 9, 2012
Step 9 – Mesh and Fill the Structure Part
9.a  Enter “50” and 
“100” for the 
number of cells 
(elements) in 
the I(X) and J(Y) 
direction

9.b  Move to the 
next step

9.c  Do not Check Fill 
with Initial 
Condition Set
Plots >
9.d  Select CONC‐ Additional
35MPA for the  Components >
material Grid

9.e  Accept the data
16 © 2011 ANSYS, Inc. March 9, 2012
Step 10 – Create an Euler Part for the Blast
10.c Enter “Blast” for 
the Part Name

10.d  Select the 
Euler, 2D Multi‐
Material Solver

10.e  Keep Part 
wizard
10.a Select
Parts On
Navigation 10.f  Move to the 
next step
Bar

10.b Select
New in the
dialog panel
17 © 2011 ANSYS, Inc. March 9, 2012
Step 11 – Define Geometry for Blast Part
11.a  Select the Box Predef (default)

11.b  Enter (‐800.0, 0.0) for the box 
origin and (1400.0,1000.0) for 
the box dimensions

11.c  Move to the next step

18 © 2011 ANSYS, Inc. March 9, 2012
Step 12 – Mesh and Fill the Blast Part
12.a  Enter “140” and “100” for the 
number of cells (elements) in 
the I(X) and J(Y) direction

12.b  Move to the next step

12.c  Check Fill with Initial 
Condition Set (Atmos is the 
only one defined)

12.d  Accept the data 

This fills the Blast Part completely 
with AIR at 1 atmosphere. The 
TNT is added next

19 © 2011 ANSYS, Inc. March 9, 2012
Step 13 – Fill  The Blast Part with 
Explosive 13.aSelect the
Blast Part
13.b Select Fill
13.c Select
Ellipse to fill a
circular region
13.d Enter
(-200.0,0.0) for
the center of the
ellipse and
“200.0” for both
semi-axes
13.e Select TNT
for the material
13.f Accept the
data
20 © 2011 ANSYS, Inc. March 9, 2012
Step 14 ‐ A Quick Review
14.a Select Notice that the Euler Blast Part
overlaps the Lagrange Structure Part.
Plots on the
This is required to allow effective
Navigation Euler-Lagrange coupling throughout
Bar the dynamic analysis

14.b Change
the options
for Material
location plots

14.c Check
Smooth
Multi-
materials

14.d Check
Grid if you
also want to
see the mesh

21 © 2011 ANSYS, Inc. March 9, 2012
Step 15 – Apply Outflow Boundary Condition
15.c  Select I Line
15.a Select Parts on the
15.d  Enter I = 1 and J = 1‐101
Navigation Bar
15.f Accept the data
15.b Select Boundary 15.g  Select I Line
15.h  Enter I = 141 and J = 1‐101
15.i  Accept the data
15.j  Select J Line
15.k  Enter I = 1‐141 and J = 101
15.l  Accept the data

22 © 2011 ANSYS, Inc. March 9, 2012
Step 16 – Set up Lagrange‐Lagrange Interactions
16.a Select Interaction on
the Navigation Bar

16.b Lagrange/Lagrange
Lagrange /
is the default choice
Lagrange
interactions are
16.c Select External Gap
required in case
the Structure
16.d Select Calculate (Concrete)
AUTODYN calculates impacts itself
the recommended gap during the
size of 1.0 mm (1/10th of dynamic analysis
the element size)

16.e Keep the defaults for


all remaining fields

23 © 2011 ANSYS, Inc. March 9, 2012
Step 17 – Set up Euler‐Lagrange Interactions

17.b Select
Euler/Lagrange
17.a Select
Interaction on 17.c Select
the Navigation Automatic
Bar (polygon free)
for the
Coupling type

24 © 2011 ANSYS, Inc. March 9, 2012
Step 18 – Set up the Detonation of the Explosive
18.a Select Detonation on the
Navigation Bar
18.b Select Point
18.c Enter (-200.0,0.0) for the
coordinates of the detonation
point
18.d Accept the data
18.e Check Plot detonation
points to view the placement

25 © 2011 ANSYS, Inc. March 9, 2012
Step 19 – Set Solution and Output Controls
19.a  Select Controls on 
the Navigation Bar

19.b  Enter a large number 
for the cycle limit and 
“0.3” ms for the Time 
Limit

19.c  Select Output on the 
Navigation Bar

19.d  Request Save files to 
be written every 
“0.01” ms 

26 © 2011 ANSYS, Inc. March 9, 2012
Step 20 – Load a Plot Settings File (3D View)

20.a  Load the plot settings 
file 
“explosive_demolition
.set”

20.b  Notice that the loaded 
plot settings provide a 
3D view where the 
model is rotated 
through 180 deg.

20.c  Extra credit: Try 
creating this view 
yourself without 
loading the settings 
file 
27 © 2011 ANSYS, Inc. March 9, 2012
Step 21 – Solve the Problem
18.a  Save your Data
The solve takes approximately 2
minutes (about 600 cycle)
18.b  Solve the 
problem

Press Stop
at any time
to interrupt
the Solve

28 © 2011 ANSYS, Inc. March 9, 2012