E.01 E.02 E.03 E.05 E.08

A: RETAIN THE EXISTING BRICK EXTERIOR. THE PAINT FINISHES ON THE BUILDING ARE NOT
ORIGINAL & MAY BE REMOVED IF APPROPRIATE & NECESSARY FOR SUBSEQUENT STABILIZATION
& REHABILITATION WORK IN ACCORDANCE WITH PRESERVATION BRIEF #1, CLEANING & WATER
E.20 REPELLANT TREATMENTS FOR HISTORIC MASONRY BUILDINGS.

B: RETAIN THE EXISTING TERRA COTTA ORNAMENTATION. REMOVE ANY LOOSE PIECES &
CAREFULLY DOCUMENT THEIR LOCATION PRIOR TO REMOVAL. STORE THE PIECES IN A SECURE
LOCATION. COVER ANY HOLES CREATED BY REMOVING PIECES WITH AN APPROPRIATE
TEMPORARY COVERING TO PREVENT ADDITIONAL MOISTURE PENETRATION INTO THE BUILDING.
8'-0" HIGH CHAIN LINK FENCE W/ BARBWIRE THE PAINT FINISHES ON THE BUILDING ARE NOT ORIGINAL & MAY BE REMOVED IF APPROPRIATE &
AT TOP ALONG SITE PERIMETER NECESSARY FOR SUBSEQUENT STABILIZATION & REHABILITATION WORK IN ACCORDANCE WITH
PRESERVATION BRIEF #1, CLEANING & WATER-REPELLENT TREATMENTS FOR HISTORIC MASONRY
BUILDINGS. ALL WORK INVOLVING THE TERRA COTTA ORNAMENTATION SHOULD BE CONSISTENT
WITH PRESERVATION BRIEF #7, THE PRESERVATION OF HISTORIC GLAZED ARCHITECTURAL
E.08 TERRA-COTTA.
E.01 E.03
2 C: RETAIN ALL EXISTING WINDOW FRAMES

E.02 A2.0 D: RETAIN EXISTING STOREFRONT INFILL.


E.05
E: REMOVE AL VEGETATION GROWING ON THE EXTERIOR OF THE BUILDING & TREAT TO PREVENT
SHEET INDEX RE-GROWTH.
A1.0 EXTERIOR NOTES & SITE PLAN F: RETAIN THE EXISTING TRANSOM
A1.0E BASEMENT FLOOR PLAN COORDINATE WITH TRAFFIC & ENGINEERING TO G: COVER ANY HOLES CREATED BY REMOVING PIECES WITH APPROPRIATE TEMPORARY
A1.1 LOBBY FLOOR PLAN CLOSE THE ON-STREET PARKING SPACES, PROVIDE COVERING TO PREVENT ADDITIONAL MOISTURE PENETRATION INTO THE BUILDING.
WARNING LIGHTS AS DIRECTED AT CORNERS ALONG
A1.1E LOBBY FLOOR PLAN - ENVIRONMENTAL STREET H: RETAIN STONE FACINGS PER NOTE B.
A1.2 2ND FLOOR PLAN E.11
A1.2E 2ND FLOOR PLAN - ENVIRONMENTAL
2
A1.3 3RD FLOOR PLAN
A2.0
A1.3E 3RD FLOOR PLAN - ENVIRONMENTAL
19
TH E.15
A1.4 4TH FLOOR PLAN

E
A1.4E 4TH FLOOR PLAN - ENVIRONMENTAL
ST
E.09 E.11
A1.5 5TH FLOOR PLAN
.(E

UE
A1.5E 5TH FLOOR PLAN - ENVIRONMENTAL
NS
A1.6 6TH FLOOR PLAN LE

EN
A1.6E 6TH FLOOR PLAN - ENVIRONMENTAL Y) 11 SITE KEY PLAN
A1.7 7TH FLOOR PLAN

AV
A1.0 SCALE: 1/32" = 1'-0"
A1.7E 7TH FLOOR PLAN - ENVIRONMENTAL
A1.8 8TH FLOOR PLAN
A1.8E 8TH FLOOR PLAN - ENVIRONMENTAL
A1.9 9TH FLOOR PLAN
A1.9E 9TH FLOOR PLAN - ENVIRONMENTAL
A1.10 10TH FLOOR PLAN & PARAPET BALCONY
A1.10E 10TH FLOOR PLAN & PARAPET BALCONY - ENVIRONMENTAL
A1.11 PENTHOUSE & ROOF PLAN
A1.11E PENTHOUSE & ROOF PLAN - ENVIRONMENTAL
A2.0 DETAILS A
C
A2.1 EXTERIOR MASONRY REPAIR
B

CONTACTS A
B
E
E B
CITY OF BIRMINGHAM BHATE ENVIRONMENTAL ASSOCIATES, INC.
PLANNING, ENGINEERING & PERMITS ATTN: CASEY GROCE B
ATTN: ANDRE BITTAS 1608 13TH AVENUE SOUTH, SUITE 300 A
710 NORTH 20TH STREET, 2ND FLOOR BIRMINGHAM, AL 35205 D C
C
BIRMINGHAM, AL 35203 (205) 918 - 4000
F
(205) 254-2336 cgroce@bhate.com
andre.bittas@birminghamal.gov

REV BIRMINGHAM SCHNEIDER HISTORIC PRESERVATION, LLC


ATTN: DAVID FLEMING ATTN: DAVID SCHNEIDER
B
505 20TH STREET NORTH, SUITE 150 411 EAST 6TH STREET
BIRMINGHAM, AL 35203 ANNISTON, AL 36207 H E.11
(205) 324 - 8797 (256) 310 - 6320
dfleming@revbirmingham.org dbschneider@bellsouth.net
ARCHITECTURE WORKS, LLP VITROLITE SPECIALIST, INC.
ATTN: RICHARD PIGFORD ATTN: TIM DUNN D
130 19TH STREET SOUTH 2402 BREDELL AVENUE
BIRMINGHAM, AL 35233 ST. LOUIS, MO 63143
(205) 320 - 0880 (314) 443 - 6238
rpigford@architectureworks.com vitrolite@earthlink.net
E.20 E.15 E.14 E.09

A1.0
E LBP-30

E 61-B-CL1-1

E 62-B-SK1-1

BOILER INSULATION
67-B-BI1-1

NOTE: ALL STANDING WATER IS TO BE REMOVED FROM THE BASEMENT.


WATER SHALL BE PASSED THROUGH A WATER FILTRATION SYSTEM
CAPABLE OF FILTERING & RETAINING PARTICLES LARGER THAN 5.0
MICRONS IN SIZE PRIOR TO BEING DISCHARGED INTO THE SANITARY
SEWER, WHICH WILL REQUIRE JEFFERSON COUNTY PERMISSION (TO BE
OBTAINED BY THE CONTRACTOR). BASEMENT TO BE LEFT IN A DRY
CONDITION.

RED FLOOR TILE AND E 64-B-DM1-1


ASSOCIATED BLACK MASTIC
65-B-FT9-1
E 66-B-SW1-1 1 BASEMENT
E 63-B-SK1-2 A1.0E SCALE: 1/8" = 1'-0"

LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.0E
D

A
G
C
A A

B C F

E
E

1.26 1.34
D
D
A
A
C
A C
A

C C

D C

G
E

1.21 1.25 1.27 1.28

C
1.46 1.45 A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS , OUTLINED

B: REMOVE SECONDARY WALLS


1.28 1.47
C: RETAIN ALL EXISTING MARBLE & STONE WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
A D FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
E DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE ELEMENTS.
1.33 C STORE ANY SALVAGED & REMOVED ELEMENTS IN A SECURE LOCATION ON SITE TO BE
1.34 APPROVED BY THE OWNER. PROTECT ANY MARBLE & STONE WALL FINISHES THAT REMAINS IN
D 1.21 PLACE DURING ALL OTHER DEMOLITION & REHABILITATION WORK.
C
1.27 1.26 1.25
1.22 D: RETAIN EXISTING DECORATIVE PLASTER CEILING.
A C
B
E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
REHABILITATION WORK.

F: RETAIN EXISTING STAIRCASE AT BASEMENT TO FIRST FLOOR, FIRST FLOOR, FIRST FLOOR TO
SECOND FLOOR, & SECOND FLOOR. PHOTOGRAPH, LABEL & KEY TO DRAWING ALL FRAGMENTS
& LOOSE ELEMENTS & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY MARBLE & STONE WALL FINISHES THAT REMAINS IN PLACE DURING ALL
OTHER STABILIZATION & REHABILITATION WORK. SEE ALLOWANCE #1
F

B B B
E

2.03

1 LOBBY FLOOR PLAN - HISTORIC


A1.1 SCALE: 1/8" = 1'-0"

A
A A
C
F C C A

E E

F
1.22
E F

F
F

1.45 2.02 1.46 1.47 F A

C
A

F
F

1.33 A1.1
FLOOR DEBRIS 9" X 9" OFF-WHITE FLOOR TILE AND
68-1-FD1-3 ASSOCIATED BLACK MASTIC
54-1-FT6-1

E LBP-23

E LBP-24

E LBP-25
E LBP-26 E 10-1-PL1-4
E 52-A-MM1-1

PIPE ELBOW INSULATION ASSOCIATED BLACK MASTIC WITH


53-1-PI2-1 12" X 12" TAN FLOOR TILE
51-1-FT5-1

E LBP-28 E LBP-27

E LBP-29

E 56-1-CT2-2 E 56-1-CT2-1
1 LOBBY FLOOR PLAN
9" X 9" BLACK FLOOR TILE AND
A1.1E SCALE: 1/8" = 1'-0"
ASSOCIATED BLACK MASTIC
58-1-FT8-1

PIPE ELBOW INSULATION 9" X 9" TAN FLOOR TILE AND GREY PIPE INSULATION WRAP ON FLOOR
(ASSUMED POSITIVE) ASSOCIATED BLACK MASTIC 59-1-PW1-1
57-1-FT7-1 LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.1E
C
C C
C

A
A A A
A G
B G A A A
C C
B
A B A B B F

B B

D
E E

2.05 2.06 2.07 2.08

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED

B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
2.32 DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
2.31 OWNER.

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.

E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
A E REHABILITATION WORK.
2.08 2.27
D D D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
2.26 LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D 2.07 2.05 2.06 D
D D D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
B G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
J WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
J
B ON SITE TO BE APPROVED BY THE OWNER.

J I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.
2.12
J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0

2.32 2.31 1 2ND FLOOR PLAN - HISTORIC


A1.2 SCALE: 1/8" = 1'-0"

3
A2.0

H
H
H I

2.27 2.26 2.12

A1.2
E 50-2-CI1-1

E 49-2-DW1-1

1 2ND FLOOR PLAN


A1.2E SCALE: 1/8" = 1'-0"

LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
PLASTER BACKING WERE IDENTIFIED AS LESS
DUCT TAPE
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.2E
A
G B
F B

D A

B H
H
I E
E

3.01 3.02 3.08 3.10

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED

B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
3.29
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
OWNER.

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
3.02 STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.

E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
A E REHABILITATION WORK.

D D D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
3.10 3.16
LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D 3.01 3.08 3.17 3.17 D
D D D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
ON SITE TO BE APPROVED BY THE OWNER.

I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.

J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0
3.07

1 3RD FLOOR PLAN - HISTORIC


A1.3 SCALE: 1/8" = 1'-0"

3
A2.0

A
A
D J D B
B F

B
E E

3.29 3.26 3.17 3.16

A1.3
E 45-3-WI1-3

NO IMAGE
E 45-3-DM1-3

E LBP-22
E LBP-19 E LBP-20
9" X 9" TAN FLOOR TILE AND ASSOCIATED E 44-3-LN1-1
BLACK MASTIC
48-3-FT4-1

E 47-3-WP1-1

E 43-3-WC1-4 E LBP-21 1 3RD FLOOR PLAN


A1.3E SCALE: 1/8" = 1'-0"

LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
PLASTER BACKING WERE IDENTIFIED AS LESS
DUCT TAPE
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.3E
A D A
A
D B B
B F
H

E E I
E

4.01 4.02 4.03 4.15

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED

B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
OWNER.

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
4.23 STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.

E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
A E REHABILITATION WORK.

D D D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
4.01 4.02 4.03 4.24 LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D D
D D D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
ON SITE TO BE APPROVED BY THE OWNER.
4.15
I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.

J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0
4.18

1 4TH FLOOR PLAN - HISTORIC


A1.4 SCALE: 1/8" = 1'-0"

3
A2.0

A D
B
B

J H
4.24 4.18

4.23

A1.4
DUCT TAPE
41-4-DT2-3

9" X 9" BROWN FLOOR TILE


AND ASSOCIATED BLACK MASTIC
42-4-FT3-1

E LBP-18

1 4TH FLOOR PLAN


A1.4E SCALE: 1/8" = 1'-0"

LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.4E
D
D A A

B F B

D
E A
E B

5.01 5.02 5.06 5.16

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED

B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
OWNER.

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.
5.22
E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
A E REHABILITATION WORK.
5.06 D D D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
D 5.01 5.02 5.17 5.16 LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D
D D D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
ON SITE TO BE APPROVED BY THE OWNER.

I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.

J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0

1 5TH FLOOR PLAN - HISTORIC


A1.5 SCALE: 1/8" = 1'-0"

3
A2.0

A
J H
B E

5.22 5.17

A1.5
WINDOW CAULK
34-5-WC1-3

E 39-5-PB1-3 E 37-5-TC2-1
E 40-5-PM1-3 E LBP-15

E LBP-17

E LBP-16

TEXTURED WALL MATERIAL


35-5-WT1-3

E 36-5-TC1-2

1 5TH FLOOR PLAN


A1.5E SCALE: 1/8" = 1'-0"

DUCT TAPE
38-5-DT2-2

LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.5E
C

C
D

A A
D E B
F B

D H
A
E B E

6.01 6.06 6.10 6.13

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED

B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
OWNER.

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.
6.32 6.32
E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
A E REHABILITATION WORK.

D D D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
D 6.10 6.06 6.01 LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D
D D D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
6.13 ON SITE TO BE APPROVED BY THE OWNER.

I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.

J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0

1 6TH FLOOR PLAN - HISTORIC


A1.6 SCALE: 1/8" = 1'-0"

3
A2.0

B
A

B J

6.32 6.31

A1.6
9" X 9" RED & 9" X 9" GREEN
CHECKERBOARD FLOOR TILE
29-6-FT1-1
30-6-FT2-1

E LBP-14

E LBP-12
E 33-6-PL1-3

E LBP-13

9" X 9" RED & 9" X 9" GREEN CHECKERBOARD


FLOOR TILE & ASSOCIATED BLACK MASTIC
31-6-FT1-2
32-6-FT2-2

WINDOW CAULK
33-6-WC1-3

E LBP-11 1 6TH FLOOR PLAN


A1.6E SCALE: 1/8" = 1'-0"

PIPE INSULATION
33-6-PI2-1
LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
PLASTER BACKING WERE IDENTIFIED AS LESS
DUCT TAPE
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.6E
C

D A
A
D A A B
B D
B F B

E
E E

7.01 7.02 7.03 7.11

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED

B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
OWNER.

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.
7.25
E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
7.03 A E REHABILITATION WORK.

D D 7.11 D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
D 7.01 7.02 7.26 LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D
D D D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
ON SITE TO BE APPROVED BY THE OWNER.

I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.

J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0

1 7TH FLOOR PLAN - HISTORIC


A1.7 SCALE: 1/8" = 1'-0"

3
A2.0

B F

B
E

J H
7.26

7.25

A1.7
DUCT TAPE
25-7-DT2-1

E LBP-6

E 27-7-WI1-2
E LBP-9
E LBP-7
E LBP-8

E LBP-10

E 28-7-DM1-4

E 23-7-PM1-2

E 24-7-PB1-2

FLOOR DEBRIS
26-7-FD1-2

1 7TH FLOOR PLAN


A1.7E SCALE: 1/8" = 1'-0"

TEXTURED WALL MATERIAL


22-7-WI1-2
LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.7E
C
C

A F D
A
D B A F
B A
B
B

8.01 8.02 8.03 8.04

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED

B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
OWNER.
A E

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.
8.28
E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
REHABILITATION WORK.
8.29
D D D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
D 8.01 8.04 8.03 LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D
D D 8.02 D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
ON SITE TO BE APPROVED BY THE OWNER.

I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.

J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0

1 8TH FLOOR PLAN - HISTORIC


A1.8 SCALE: 1/8" = 1'-0"

3
A2.0

C
J B

H
A

F B

8.29 8.28

A1.8
DUCT TAPE
19-8-DT1-1

E 20-8-DW1-1

E 20-8-DW1-3

TEXTURED CEILING MATERIAL


17-8-TC1-1

1 8TH FLOOR PLAN


A1.8E SCALE: 1/8" = 1'-0"

VERTICAL PIPE INSULATION IN WALL TEXTURED WALL MATERIAL


21-8-PI1-1 18-8-WT1-1
LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.8E
A

D C

A
A D
B B
F
J H

9.01 9.02 9.10 9.35

A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
TRANSOMS, OUTLINED
REMOVE STAIRS THIS LEVEL, UP TO ROOF
B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
DEMOLITION & REHABILITATION WORK.

C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
F REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
G
OWNER.
A E

D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.
9.35
E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
REHABILITATION WORK.

D D D D F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
D 9.10 9.01 9.36 LOCATION ON SITE TO BE APPROVED BY THE OWNER.
D
D D 9.02 D D D D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
ON SITE TO BE APPROVED BY THE OWNER.

I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.

J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0

1 9TH FLOOR PLAN - HISTORIC


A1.9 SCALE: 1/8" = 1'-0"

3
A2.0

9.36

A1.9
E 15-9-DM1-2

E 16-9-PL1-3

1 9TH FLOOR PLAN


A1.9E SCALE: 1/8" = 1'-0"

FLOOR DEBRIS
14-9-FD1-2
LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.9E
C C

A A
F
B D B

10.14
10.1 10.2 10.3 10.13

1. CONTRACTOR TO VERIFY EXISTING ROOF CONDITIONS TO VERIFY ALL EXISTING PRIOR TO SUBMITTING A: RETAIN THE EXISTING ELEVATOR LOBBY WALLS INCLUDING ALL EXISTING DOOR FRAMES &
BID. TRANSOMS, OUTLINED
REMOVE STAIRS THIS LEVEL, UP TO ROOF
2. EXISTING ROOF MEMBRANE & COMPOSITION BASE FLASHING TO REMAIN IN PLACE UNLESS B: RETAIN ALL EXISTING STRUCTURAL GLASS WALL FINISHES. SALVAGE ANY PANELS THAT HAVE
OTHERWISE INDICATED. FALLEN & THAT REMAIN RELATIVELY INTACT (AT LEAST 40% OF ORIGINAL SIZE WITH A FULL
DIMENSION ALONG EITHER THEIR LENGTH OR WIDTH). CAREFULLY REMOVE LOOSE PANELS IN
3. BROOM, SWEEP, SPUD EXISTING GRAVEL SURFACING ELIMINATING ALL LOOSE GRAVEL, DEBRIS & ACCORDANCE WITH PRESERVATION BRIEF #12, THE PRESERVATION OF HISTORIC PIGMENTED
OTHER FOREIGN MATERIALS FROM THE ROOF SURFACE. E.40 SEE ROOFING NOTES E.30 SEE ROOFING NOTES E.28 E.31 STRUCTURAL GLASS & IN COORDINATION WITH TIM DUNN, VITROLITE SPECIALIST, INC. STORE ANY
SALVAGED AND REMOVED PANELS IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
4. INSTALL FOUR (4) NEW ROOF DRAINS AT THE 10TH FLOOR LEVEL ROOF AREA CONNECTING TO THE OWNER. PROTECT ANY STRUCTURAL GLASS THAT REMAINS IN PLACE DURING ALL OTHER
EXISTING ROOF DRAIN LEADER SYSTEM UNDER THE ROOF DECK. DEMOLITION & REHABILITATION WORK.

5. INSTALL FOUR (4) NEW ROOF DRAINS AT THE 11TH FLOOR LEVEL ROOF AREA CONNECTING TO THE F C: RETAIN ALL EXISTING CEILING CORNICES. WHERE CEILINGS ARE TO BE REMOVED, CAREFULLY
EXISTING ROOF DRAIN LEADER SYSTEM UNDER THE ROOF DECK. G REMOVE THE CORNICES & STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE
OWNER.
6. INSTALL TWO (2) NEW ROOF DRAINS AT THE 12TH FLOOR LEVEL (PENTHOUSE) ROOF AREA
CONNECTING TO THE EXISTING ROOF DRAIN LEADER SYSTEM UNDER THE ROOF DECK D D: RETAIN ALL EXISTING DOORS. KEY THEIR LOCATIONS ON A DRAWING BY FLOOR & OPENING &
STORE THEM IN A SECURE LOCATION ON SITE TO BE APPROVED BY THE OWNER.
10.25
7. PREPARE & CLEAN EXISTING ROOF MEMBRANE IN ACCORDANCE WITH THE FLUID APPLIED ROOF 10.14
MEMBRANE MANUFACTURERS' INSTRUCTIONS & ANY OTHER PROJECT SPECIFIC REQUIREMENTS. A E E: PROTECT ALL MARBLE FLOORING IN THE CORRIDORS DURING ALL OTHER DEMOLITION &
REHABILITATION WORK.
8. APPLY NEW FLUID APPLIED ROOF MEMBRANE SYSTEM TO ALLOW SLOPED ROOF SURFACES IN 10.03
D D D D
ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS, REFERENCED DETAILS & SPECIFICATIONS. F: RETAIN EXISTING ELEVATOR DOORS FROM THE LOWER 5 FLOORS & STORE THEM IN A SECURE
D 10.01 10.02 10.13 D LOCATION ON SITE TO BE APPROVED BY THE OWNER.
9. APPLY NEW FLUID APPLIED ROOF MEMBRANE SYSTEM TO ALL VERTICAL PARAPET WALLS & SELF
TERMINATING ON ONE BRICK COURSE ABOVE EXISTING FLASHING IN ACCORDANCE WITH THE D D D D D 10.19 D G. RETAIN ALL REMAINING CABINETS & VESTIGES OF THE MAIL CHUTES IN PLACE
MANUFACTURERS' INSTRUCTIONS, REFERENCE DETAILS & SPECIFICATIONS. G B C
H: RETAIN ALL WINDOW SILLS. IF THEY MUST BE REMOVED TO ALLOW FOR OTHER STABILIZATION
10. APPLY NEW FLUID APPLIED ROOF MEMBRANE SYSTEM TO ALL BASE FLASHING AT BASE OF WORK, REMOVE SO AS NOT TO BREAK OR DAMAGE THEM & STORE THEM IN A SECURE LOCATION
PENTHOUSE WALLS SELF TERMINATING ONE BRICK COURSE ABOVE COMPOSITION BASE FLASHING ON SITE TO BE APPROVED BY THE OWNER.
SURFACES IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS, REFERENCE DETAILS &
SPECIFICATIONS. I: RETAIL SAMPLES OF ALL BASEBOARDS & DOOR JAMBS SUFFICIENT TO ALLOW FOR POSSIBLE
LATER REPRODUCTION.
11. DETAIL ALL ROOF PENETRATIONS, DRAINS SCUPPERS & ALL OTHER ROOF EQUIPMENT INCLUDING
ROOF CURBS & FIXTURES IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS, REFERENCED J: RETAIN THE EXISTING BATHROOM WALLS INCLUDING ALL EXISTING STALL SYSTEMS; FIXTURES
DETAILS & SPECIFICATIONS MAY BE REMOVED BUT REMOVAL SHOULD BE ACCOMPLISHED SO AS TO NOT DAMAGE THE
STRUCTURAL GLASS WALLS TO WHICH THEY ARE ATTACHED.

GENERAL NOTE: PROVIDE FOUR (4) LOUVERS PER FLOOR FOR VENTILATION, SEE DETAIL 2/A2.0

SEE ROOFING NOTES E.34 1 10TH FLOOR PLAN & PARAPET BALCONY- HISTORIC
A1.10 SCALE: 1/8" = 1'-0"

3
A2.0

A D
D
B

B
10.19

E.40 E.34 E.31 E.30 E.28 10.25

A1.10
FLOORING DEBRIS
13-10-FD1-1

E 6-10-WI1-1

E 7-10-PM1-1

E 8-10-PB1-1

E 12-10-DM1-1
AIRCELL PIPE INSULATION
10-10-AC1-1

E 9-10-PL1-2

E LBP-5

1 10TH FLOOR PLAN & PARAPET BALCONY


A1.10E SCALE: 1/8" = 1'-0"

EXTERIOR WINDOW CAULK


11-10-WC1-1
LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.10E
SEE ROOFING NOTES

E.45 E.46 E.47

1. CONTRACTOR TO VERIFY EXISTING ROOF CONDITIONS TO VERIFY ALL EXISTING PRIOR TO SUBMITTING
BID.
REMOVE STAIRS THIS LEVEL, INCLUDING STAIRS TO UPPER PENTHOUSE
2. EXISTING ROOF MEMBRANE & COMPOSITION BASE FLASHING TO REMAIN IN PLACE UNLESS
OTHERWISE INDICATED.

3. BROOM, SWEEP, SPUD EXISTING GRAVEL SURFACING ELIMINATING ALL LOOSE GRAVEL, DEBRIS &
OTHER FOREIGN MATERIALS FROM THE ROOF SURFACE.

4. INSTALL FOUR (4) NEW ROOF DRAINS AT THE 10TH FLOOR LEVEL ROOF AREA CONNECTING TO THE
EXISTING ROOF DRAIN LEADER SYSTEM UNDER THE ROOF DECK.

5. INSTALL FOUR (4) NEW ROOF DRAINS AT THE 11TH FLOOR LEVEL ROOF AREA CONNECTING TO THE
EXISTING ROOF DRAIN LEADER SYSTEM UNDER THE ROOF DECK.

6. INSTALL TWO (2) NEW ROOF DRAINS AT THE 12TH FLOOR LEVEL (PENTHOUSE) ROOF AREA
CONNECTING TO THE EXISTING ROOF DRAIN LEADER SYSTEM UNDER THE ROOF DECK

E.50 7. PREPARE & CLEAN EXISTING ROOF MEMBRANE IN ACCORDANCE WITH THE FLUID APPLIED ROOF
MEMBRANE MANUFACTURERS' INSTRUCTIONS & ANY OTHER PROJECT SPECIFIC REQUIREMENTS.

8. APPLY NEW FLUID APPLIED ROOF MEMBRANE SYSTEM TO ALLOW SLOPED ROOF SURFACES IN
ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS, REFERENCED DETAILS & SPECIFICATIONS.

9. APPLY NEW FLUID APPLIED ROOF MEMBRANE SYSTEM TO ALL VERTICAL PARAPET WALLS & SELF
E.51 E.45 TERMINATING ON ONE BRICK COURSE ABOVE EXISTING FLASHING IN ACCORDANCE WITH THE
MANUFACTURERS' INSTRUCTIONS, REFERENCE DETAILS & SPECIFICATIONS.

3 10. APPLY NEW FLUID APPLIED ROOF MEMBRANE SYSTEM TO ALL BASE FLASHING AT BASE OF
PENTHOUSE WALLS SELF TERMINATING ONE BRICK COURSE ABOVE COMPOSITION BASE FLASHING
A2.0
SURFACES IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS, REFERENCE DETAILS &
SEE ROOFING NOTES SPECIFICATIONS.
E.49
E.46
11. DETAIL ALL ROOF PENETRATIONS, DRAINS SCUPPERS & ALL OTHER ROOF EQUIPMENT INCLUDING
ROOF CURBS & FIXTURES IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS, REFERENCED
APPLY ROOF MEMBRANE UP ONE E.48 DETAILS & SPECIFICATIONS
BRICK COURSE ABOVE EXISTING E.47
FLASHING

2 DETAIL @ ROOF MEMBRANE 1 PENTHOUSE & ROOF PLAN - HISTORIC


A1.11 SCALE: 12" = 1'-0" A1.11 SCALE: 1/8" = 1'-0"

E.49 E.50 E.51 E.48

A1.11
1 PENTHOUSE & ROOF PLAN
A1.11E SCALE: 1/8" = 1'-0"
GENERAL NOTE: NO ABATEMENT THIS LEVEL, PROVIDED FOR INFORMATION ONLY

BLACK FLASHING GREY FLASHING


2-RF1-1 3-RF2-1
LEGEND:
E POSITIVE LEAD PAINT SAMPLE GENERAL NOTE:
THIS INFORMATION IS DEPICTED TO PROVIDE VISUAL AID
WITHIN THE CONTEXT OF THESE DOCUMENTS & THE
E NEGATIVE LEAD PAINT SAMPLE BHATE ASSOCIATES LIMITED HAZARDOUS MATERIALS
SURVEY DATED 2/18/11. THIS REPORT SHOULD NOT BE
USED AS A SOLE REFERENCE IN PRECISE DIMENSIONING
E POSITIVE ASBESTOS SAMPLE OF FEATURES INDICATED. PLEASE VERIFY THE LOCATION
OF ALL FEATURES INCLUDING UNDERGROUND &
ABOVEGROUND UTILITIES PRIOR TO CONDUCTING ANY
E NEGATIVE ASBESTOS SAMPLE SUBSURFACE EXPLORATION OR SITE ASSESSMENT

PHOTO LOCATION GENERAL NOTE:


FLOOR DEBRIS ON ALL LEVELS
THERMAL SYSTEM INSULATION (TSI)
NOTE: TSI IS ALSO VERTICAL AT BUILDING
GENERAL NOTE:
ENVELOPE, RUNS GROUND FLOOR TO ROOF
ONLY TEXTURED WALL & CEILING MATERIALS
CONTAIN ASBESTOS. ALL SMOOTH COATINGS &
DUCT TAPE PLASTER BACKING WERE IDENTIFIED AS LESS
THAN 1% ASBESTOS & THEREFORE DO NOT
REQUIRE SPECIAL HANDLING, SEE LIMITED
HAZARDOUS MATERIAL SURVEY
FLOOR TILE & MASTIC
GENERAL NOTE:
DUCT TAPE VISIBLE IN MECHANICAL ROOMS TO BE
REMOVED EVERYWHERE. POSSIBLE LOCATIONS
ELEVATOR FIRE DOORS COULD INCLUDE BUT NOT BE LIMITED TO ENTIRE
CORRIDOR. SHOULD BE HANDLED WITH CEILING
REMOVAL A1.11E
1
A2.0

PT DOUBLE TOP PLATE


REMOVE BROKEN GLASS, TYPICAL
.
EQ

ROOFING UNDERLAYMENT ON PT
PLYWOOD

PT 2 X 4 FRAMING, DO NOT
PT 2 X 4 RAFTERS @ 24" O.C. ANCHOR TO FACE OF EXISTING
BUILDING

CLOSE OPEN WINDOWS, TYPICAL


.
EQ

3/4" MARINE GRADE PLYWOOD,


TAP CON @ 12" O.C. TO EXISTING FRAME

3'
BA -0
RB "
FRAME BEYOND W
IR
E
SHOWN DASHED

LEAVE EXISTING PLYWOOD,


REPLACE IF DAMAGED OR MISSING

PROVIDE FOUR (4) SQUARE


HEIGHT VARIES W/ SLOPE OF SIDEWALK

LOUVERS W/ INSECT
SCREENING PER FLOOR,
INSTALLED IN PLYWOOD,
BETWEEN WINDOW
MULLIONS
8' - 0"

PT 2 X 4 FRAMING, ANCHOR TO
CHAIN LINK CONSTRUCTION FENCE

EXISTING SIDEWALK AS
3/4 DEPTH REQUIRED

OF CURBSIDE PARKING

6' - 0"
3' - 0"

3 TYP. WINDOW DETAIL 1 DETAIL @ BARRICADE


A2.0 SCALE: NTS A2.0 SCALE: 1/2" = 1'-0"

A2.0
WINDOW LENTILS MAY BE ERODED SOME LOCATIONS & REQUIRE REPLACEMENT

GENERAL NOTE - CLEANING/ PAINT REMOVAL GENERAL NOTE - HORIZONTAL CONTROL JOINTS
REMOVAL OF THIS COATING SHOULD BE INSTALL SEALANT JOINT AT THESE LOCATION,
CONSIDERED AS IT IS LIKELY NOT A BREATHABLE SOME MOVEMENT MAY OCCUR WITHOUT CREATING
COATING & MAY BE TRAPPING MOISTURE WITHIN THE A SOURCE OF WATER INFILTRATION
MOISTURE SYSTEM.
INCLUDE 2894 LINEAR FEET
INCLUDE 26,880 SQUARE FEET

HORIZONTAL CONTROL JOINTS AT FLOOR


SHELF ANGLES WILL LIKELY NEED TO BE
INSTALLED AT EACH FLOOR

GENERAL NOTE - WINDOW LINTELS


ASSUME ALL LINTELS TOP TWO FLOORS WILL
REQUIRE REPLACEMENT & POSSIBLY 10% FOR
A A A B B B A A A OTHER FLOORS

INCLUDE 376 LINEAR FEET

WINDOWS

A APPROX. 3'- 0" X 6'- 8", 204 WINDOWS TOTAL


CURRENT COATING ON BRICK & STONE
TO BE REMOVED, UNKNOWN IF
COATING CONTAINS LEAD B APPROX. 3'- 4" X 6'- 8", 278 WINDOWS TOTAL

GENERAL NOTE - PARAPETS:


BRICK PARAPET WILL NEED TO BE
REPOINTED ON BOTH THE ROOF SIDE
ALL WINDOW LINTELS ABOVE THIS
& EXTERIOR SIDE FROM THE ROOF
LEVEL TO BE REPLACED, 105
DECK UPWARDS, ALL PARAPET
LOCATIONS TO BE CONSIDERED

INCLUDE 2000 SQUARE FEET

GENERAL NOTE - LIMESTONE COPING


LIMESTONE JOINTS ARE LIKELY
CRACKED & REQUIRE REPOINTING OR WINDOWS
SEALANT JOIN INSTALLED. INSTALL
SEALANT JOINT WITH A SAND APPLIED
TO SURFACE AFTER TOOLING TO B B B A A A A APPROX. 3'- 0" X 6'- 8", 204 WINDOWS TOTAL
B B B B B B B B B
REPLICATE MORTAR JOINT A A A
B APPROX. 3'- 4" X 6'- 8", 278 WINDOWS TOTAL
INCLUDE 534 LINEAR FEET

LIMESTONE COPING JOINTS WILL


LIKELY REQUIRE REPOINTING OR
SEALANT JOINT INSTALLED

A2.1