CONTENTS
1
S.No. Contents Page
1. Abbreviations
2. Abstract
3. Introduction
5. Block diagram
6. Block diagram Description
7. Schematic
8. Schematic Description (pin to pin connectivity)
9. Hardware components
a. Microcontroller (max 50 pages)
b. MAX 232
c. Power supply
d. ADC
e. Current sensor
f. LCD
g. Relay
ABBREVIATIONS
Symbol Name
2
ACC Accumulator
B B register
PSW Program status word
SP Stack pointer
DPTR Data pointer 2 bytes
DPL Low byte
DPH High byte
P0 Port0
P1 Port1
P2 Port2
P3 Port3
IP Interrupt priority control
IE Interrupt enable control
TMOD Timer/counter mode control
TCON Timer/counter control
T2CON Timer/counter 2 control
T2MOD Timer/counter mode2 control
TH0 Timer/counter 0high byte
TL0 Timer/counter 0 low byte
TH1 Timer/counter 1 high byte
TL1 Timer/counter 1 low byte
TH2 Timer/counter 2 high byte
TL2 Timer/counter 2 low byte
SCON Serial control
SBUF Serial data buffer
PCON Power control
Figure Locations
3
12 B register
13 RAM
14 RAM Allocation
15 Register Banks
16 PSW
17 DPTR
18 SP
19 PORT 0
20 TL0 and TH0
21 DB9
22 Connecting Microcontroller to PC
Types of SIM Structures
23
Smart Card Pin-out
24
Smart Card Reader
25
LCD
26
MAX 232 Pin-out
27
MAX 232 Operating circuit
28
MAX 232 Logic output
29
Relay
30
Project
31
New Project
32
Select Target device
33
Select device for Target
34
Copy 8051 startup code
35
Source group 1
36
New file
37
Opened new file
38
File Save
39
Add files to the source group
40
Adding files to the source group
41
4
Compilation
42
After Compilation
43
Build
44
Selecting the Ports to be visualized
45
Start Debugging
46
47
CHAPTER 1
1. INTRODUCTION
5
1.1 EMBEDDED SYSTEMS:
6
INTRODUCTION TO THE PROJECT:
The transfers switch senses when utility power is interrupted, and starts up the
transformer TF2 which acts as a backup transformer. If the utility power remains absent,
the transfer switch disconnects the load from the utility and connects it to the Transformer
TF2, restoring electricity to the load. The transfer switch continues to monitor utility
power, and when it is restored, switches the load from the Transformer TF2 back to the
Main transformer TF1. Once the Transformer TF2 is disconnected, it goes through a cool-
down routine and is automatically shut down.
The objective of the present project is to satisfy the above needs with an extent.
The present system is designed around two transformers. One transformer (TF1) is used
as the main supply and the other transformer (TF2) is used in the place of the generator
(for demo purpose). These two transformers are connected with the relay which is
controlled by the embedded controller. The loads are connected to the main line (TF1)
and as well as to the TF2.
Initially TF1 is connected to the load, the loads run with this power. Due to any
reason this power is interrupted, then it is identified by the controller and it immediately
switches ON to the TF2 through the relay. The controller continuously monitors the TF1
(main line). When it finds the power on it again switches the loads connection to the main
line. All the status of the transformers will be displayed on LCD.
AT
BLOCK DIAGRAM: 89C51
MICRO
CONTROLLER
7
POWER SUPPLY LCD DISPLAY
LOAD
Main
Transformer
(TF1)
RELAY
ADC
Sharing
transformer
(TF2) CURRENT
SENSOR
The above block diagram gives the overview of the project in the pictorial form
with the help of the block diagram we will create pre model of the project and the analyze
the function of the project the explanation of the project with block diagram over view is
given as follows.
This section is meant for supplying Power to all the sections mentioned above. It
basically consists of a Transformer to step down the 230V ac to 18V ac followed by
8
diodes. Here diodes are used to rectify the ac to dc. After rectification the obtained
rippled dc is filtered using a capacitor Filter. A positive voltage regulator is used to
regulate the obtained dc voltage.
Microcontroller Section:
This section forms the control unit of the whole project. This section basically
consists of a Microcontroller with its associated circuitry like Crystal with capacitors,
Reset circuitry, Pull up resistors (if needed) and so on. The Microcontroller forms the
heart of the project because it controls the devices being interfaced and communicates
with the devices according to the program being written.
Transformers:
In general, the ac line voltage present in your house wiring is not suitable for
electronic circuits. Most circuits require a considerably lower voltage, while a few require
higher voltages. The transformer serves to convert the ac line voltage to a voltage level
more appropriate to the needs of the circuit to be powered. At the same time, the
transformer provides electrical isolation between the ac line and the circuit being
powered, which is an important safety consideration. However, a line transformer is
generally large and heavy, and is rather expensive. Therefore, some power supplies
(notably for PCs) are deliberately designed to operate directly from the ac line without a
line transformer. The output of the transformer is still an ac voltage, but now of an
appropriate magnitude for the circuit to be powered.
ADC:
Analog to digital (A/D, ADC) converters are electrical circuit devices that convert
continuous signals, such as voltages or currents, from the analog domain to the digital
domain where the signals are represented by numbers.
9
This section is basically meant to show up the status of the project. This
project makes use of Liquid Crystal Display to display / prompt for necessary
information.
Sensors:
This part of the system consists of current sensor. These sensor sense various
parameters of load- current and are then sent to the Analog to Digital Converter.
Relay:
In this project Relays are used to the Trip the transformer. A relay is an
electrical switch that opens and closes under control of another electrical circuit. In the
original form, the switch is operated by an electromagnet to open or close one or many
sets of contacts.
SCHEMATIC:
10
SCHEMATIC EXPLANATION:
Firstly, the required operating voltage for Microcontroller 89C51 is 5V.
Hence the 5V D.C. power supply is needed by the same. This regulated 5V is generated
by first stepping down the 230V to 18V and 12 V operating voltage for relays. Hence
another supply is required to generate 12V.
The step downed a.c voltage is being rectified by the Bridge Rectifier. The
diodes used are 1N4007. The rectified a.c voltage is now filtered using a ‘C’ filter. Now
the rectified, filtered D.C. voltage is fed to the Voltage Regulator. This voltage regulator
allows us to have a Regulated Voltage which is +5V. We are using two voltage regulators
i.e., 7805 and 7812. These voltage regulators regulate 5v for microcontroller and 12v for
relays. The rectified; filtered and regulated voltage is again filtered for ripples using an
electrolytic capacitor 100μF. Now the output from this section is fed to 40 th pin of 89c51
microcontroller to supply operating voltage.
11
The microcontroller 89C51 with Pull up resistors at Port0 and crystal
oscillator of 11.0592 MHz crystal in conjunction with couple of capacitors of is placed at
18th & 19th pins of 89c51 to make it work (execute) properly.
The LCD is interfaced to Microcontroller. The data pins of LCD are connected to
Port 0. The control pins of LCD are connected to Port 2 as shown in schematic.
One of the port 3 pin is connected to the secondary side of transformer one
through bridge rectifier and regulator to check the status of the transformer one i.e
whether the power supply is on or off to the transformer one through relay. Relay is used
to on & off the transformer occurred it is connected to P2.0 microcontroller.
The data pins of ADC are connected to the port 1 of microcontroller. What ever
the data in ADC from C.T (current transformer) will be converted from analog to digital
and fed it to the microcontroller.
CHAPTER III
HARDWARE Components
12
The Hardware components used in this project are
Regulated Power Supply
Microcontroller
Transformers
Relay
ADC
Current sensor
LCD
INTRODUCTION:
13
A Micro controller consists of a powerful CPU tightly coupled with memory
RAM, ROM or EPROM), various I / O features such as Serial ports, Parallel Ports,
Timer/Counters, Interrupt Controller, Data Acquisition interfaces-Analog to Digital
Converter (ADC), Digital to Analog Converter (ADC), everything integrated onto a
single Silicon Chip.
It does not mean that any micro controller should have all the above said features
on chip, Depending on the need and area of application for which it is designed, The ON-
CHIP features present in it may or may not include all the individual section said above.
Advantages of microcontrollers:
14
COMPARISON
Data bus
CPU
General I/O SERIAL
RAM ROM PORT TIMER COM
purpose
Micro PORT
Processor
Address bus
15
A system designer using a general-purpose microprocessor such as the Pentium or
the 68040 must add RAM, ROM, I/O PORTS, and TIMERS externally to make them
functional. Although the addition of external RAM, ROM and I/O PORTS makes these
systems bulkier and much expensive, they have the advantage of versatility such that the
designer can decide on the amount of RAM, ROM and I/O PORTS needed to fit the task
at hand this is not the case with microcontrollers.
The 8051 is an 8-bit processor, meaning that the CPU can work on only 8-bits of
data at a time. Data larger than 8-bits has to be broken into 8-bit pieces to be processed by
the CPU. The 8051 can have a maximum of 64K bytes of ROM; many manufacturers
have put only 4Kbytes on chip.
16
A Micro controller consists of a powerful CPU tightly coupled with memory,
various I/O interfaces such as serial port, parallel port timer or counter, interrupt
controller, data acquisition interfaces-Analog to Digital converter, Digital to Analog
converter, integrated on to a single silicon chip. If a system is developed with a
microprocessor, the designer has to go for external memory such as RAM, ROM,
EPROM and peripherals. But controller is provided all these facilities on a single chip.
Development of a Micro controller reduces PCB size and cost of design. One of the
major differences between a Microprocessor and a Micro controller is that a controller
often deals with bits not bytes as in the real world application. Intel has introduced a
family of Micro controllers called the MCS-51.
o Why AT 89C51? :
17
The system requirements and control specifications clearly rule out the use of 16,
32 or 64 bit micro controllers or microprocessors. Systems using these may be earlier to
implement due to large number of internal features. They are also faster and more reliable
but, the above application is satisfactorily served by 8-bit micro controller. Using an
inexpensive 8-bit Microcontroller will doom the 32-bit product failure in any competitive
market place.
Coming to the question of why to use AT89C51 of all the 8-bit microcontroller
available in the market the main answer would be because it has 4 Kb on chip flash
memory which is just sufficient for our application. The on-chip Flash ROM allows the
program memory to be reprogrammed in system or by conventional non-volatile memory
Programmer. Moreover ATMEL is the leader in flash technology in today’s market place
and hence using AT 89C51 is the optimal solution.
18
Two external and three internal interrupts sources.
Oscillator and clock circuits.
The heart of the 89C51 circuitry that generates the clock pulses by which all the
internal all internal operations are synchronized. Pins XTAL1 And XTAL2 is provided
for connecting a resonant network to form an oscillator. Typically a quartz crystal and
capacitors are employed. The crystal frequency is the basic internal clock frequency of
the microcontroller. The manufacturers make 89C51 designs that run at specific
minimum and maximum frequencies typically 1 to 16 MHz.
19
Oscillator and timing circuit
Types of memory:
The 89C51 have three general types of memory. They are on-chip memory,
external Code memory and external Ram. On-Chip memory refers to physically existing
memory on the micro controller itself. External code memory is the code memory that
resides off chip. This is often in the form of an external EPROM. External RAM is the
Ram that resides off chip. This often is in the form of standard static RAM or flash
RAM.
20
a) Code memory
Code memory is the memory that holds the actual 89C51 programs that is to be
run. This memory is limited to 64K. Code memory may be found on-chip or off-chip. It is
possible to have 4K of code memory on-chip and 60K off chip memory simultaneously.
If only off-chip memory is available then there can be 64K of off chip ROM. This is
controlled by pin provided as EA
b) Internal RAM
The 89C51 have a bank of 128 of internal RAM. The internal RAM is found on-
chip. So it is the fastest Ram available. And also it is most flexible in terms of reading
and writing. Internal Ram is volatile, so when 89C51 is reset, this memory is cleared. 128
bytes of internal memory are subdivided. The first 32 bytes are divided into 4 register
banks. Each bank contains 8 registers. Internal RAM also contains 128 bits, which are
addressed from 20h to 2Fh. These bits are bit addressed i.e. each individual bit of a byte
can be addressed by the user. They are numbered 00h to 7Fh. The user may make use of
these variables with commands such as SETB and CLR.
FLASH MEMORY:
Flash memory gets its name because the microchip is organized so that a section
of memory cells are erased in a single action or "flash." The erasure is caused by Fowler-
21
Nordheim tunneling in which electrons pierce through a thin dielectric material to remove
an electronic charge from a floating gate associated with each memory cell. Intel offers a
form of flash memory that holds two bits (rather than one) in each memory cell, thus
doubling the capacity of memory without a corresponding increase in price.
Flash memory is used in digital cellular phones, digital cameras, LAN switches,
PC Cards for notebook computers, digital set-up boxes, embedded controllers, and other
devices.
Memory Types
22
Memory Type Features
FLASH Low-cost, high-density, high-speed
architecture; low power; high reliability
ROM Mature, high-density, reliable, low cost;
Read-Only Memory time-consuming mask required, suitable
for high production with stable code
SRAM Highest speed, high-power, low-density
Static Random-Access Memory memory; limited density drives up cost
EPROM High-density memory; must be exposed
Electrically Programmable Read-Only to ultraviolet light for erasure
Memory
EEPROM or E2 Electrically byte-erasable; lower
Electrically Erasable Programmable reliability, higher cost, lowest density
Read-Only Memory
DRAM High-density, low-cost, high-speed,
Dynamic Random Access Memory high-power
Flash memory is a nonvolatile memory using NOR technology, which allows the
user to electrically program and erase information. Intel® Flash memory uses memory
cells similar to an EPROM, but with a much thinner, precisely grown oxide between the
floating gate and the source (see Figure 2). Flash programming occurs when electrons are
placed on the floating gate. The charge is stored on the floating gate, with the oxide layer
allowing the cell to be electrically erased through the source. Intel Flash memory is an
extremely reliable nonvolatile memory architecture.
23
Pin diagram of AT89C51
Pin Description:
GND: Ground.
Port 0:
24
Port 0 is an 8-bit open-drain bi-directional I/O port. As an output port, each pin
can sink eight TTL inputs. When 1’s are written to port 0 pins, the pins can be used as
high impedance inputs. Port 0 may also be configured to be the multiplexed low order
address/data bus during accesses to external program and data memory. In this mode P0
has internal pull-ups. Port 0 also receives the code bytes during Flash programming, and
outputs the code bytes during program verification. External pull-ups are required during
program verification.
Port 1:
Port 1 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 1 output
buffers can sink/source four TTL inputs. When 1s are written to Port 1 pins they are
pulled high by the internal pull-ups and can be used as inputs. As inputs, Port 1 pins that
are externally being pulled low will source current (IIL) because of the internal pull-ups.
Port 1 also receives the low-order address bytes during Flash programming and
verification.
Port 2:
Port 2 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 2 output
buffers can sink/source four TTL inputs. When 1s are written to Port 2 pins they are
pulled high by the internal pull-ups and can be used as inputs. As inputs, Port 2 pins that
are externally being pulled low will source current (IIL) because of the internal pull-ups.
Port 2 emits the high-order address byte during fetches from external program memory
and during accesses to external data memories that use 16-bit addresses (MOVX
@DPTR). In this application, it uses strong internal pull-ups when emitting 1s. During
accesses to external data memories that use 8-bit addresses (MOVX @ RI), Port 2 emits
the contents of the P2 Special Function Register. Port 2 also receives the high-order
address bits and some control signals during Flash programming and verification.
Port 3:
25
Port 3 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 3 output
buffers can sink/source four TTL inputs. When 1s are written to Port 3 pins they are
pulled high by the internal pull-ups and can be used as inputs. As inputs, Port 3 pins that
are externally being pulled low will source current (IIL) because of the pull-ups.
Port 3 also serves the functions of various special features of the AT89C51 as listed
below:
Port 3 also receives some control signals for Flash programming and verification
RST:
Reset input. A high on this pin for two machine cycles while the oscillator is
running resets the device.
ALE/PROG:
Address Latch Enable output pulse for latching the low byte of the address during
accesses to external memory. This pin is also the program pulse input (PROG) during
Flash programming. In normal operation ALE is emitted at a constant rate of 1/6the
oscillator frequency, and may be used for external timing or clocking purposes. Note,
however, that one ALE pulse is skipped during each access to external Data Memory.
26
If desired, ALE operation can be disabled by setting bit 0 of SFR location 8EH. With the
bit set, ALE is active only during a MOVX or MOVC instruction. Otherwise, the pin is
weakly pulled high. Setting the ALE-disable bit has no effect if the microcontroller is in
external execution mode.
PSEN:
Program Store Enable is the read strobe to external program memory. When the
AT89C51 is executing code from external program memory, PSEN is activated twice
each machine cycle, except that two PSEN activations are skipped during each access to
external data memory.
EA/VPP:
External Access Enable (EA) must be strapped to GND in order to enable the
device to fetch code from external program memory locations starting at 0000H up to
FFFFH.
Note, however, that if lock bit 1 is programmed, EA will be internally latched on
reset.
EA should be strapped to VCC for internal program executions. This pin also receives the
12-volt programming enable voltage (VPP) during Flash programming, for parts that
require 12-volt VPP.
XTAL1:
Input to the inverting oscillator amplifier and input to the internal clock operating
circuit.
XTAL2:
Out put from the inverting oscillator amplifier.
Oscillator Characteristics:
XTAL1 and XTAL2 are the input and output, respectively, of an inverting
amplifier which can be configured for use as an on-chip oscillator, as shown in Figs 6.2.3.
Either a quartz crystal or ceramic resonator may be used. To drive the device from an
external clock source, XTAL2 should be left unconnected while XTAL1 is driven as
27
shown in Figure 6.2.4.There are no requirements on the duty cycle of the external clock
signal, since the input to the internal clocking circuitry is through a divide-by-two flip-
flop, but minimum and maximum voltage high and low time specifications must be
observed.
Notes:
1. Under steady state (non-transient) conditions, IOL must be externally limited as
follows:
Maximum IOL per port pin: 10 mA
Maximum IOL per 8-bit port: Port 0: 26 mA
Ports 1, 2, 3: 15 mA
Maximum total IOL for all output pins: 71 mA
If IOL exceeds the test condition, VOL may exceed the related specification.
Pins are not guaranteed to sink current greater than the listed test conditions.
2. Minimum VCC for Power-down is 2V.
Types of memory:
The 8051 have three general types of memory. They are on-chip memory, external
Code memory and external Ram. On-Chip memory refers to physically existing memory
28
on the micro controller itself. External code memory is the code memory that resides off
chip. This is often in the form of an external EPROM. External RAM is the Ram that
resides off chip. This often is in the form of standard static RAM or flash RAM.
b) Code memory
Code memory is the memory that holds the actual 8051 programs that is to be run.
This memory is limited to 64K. Code memory may be found on-chip or off-chip. It is
possible to have 4K of code memory on-chip and 60K off chip memory simultaneously.
If only off-chip memory is available then there can be 64K of off chip ROM. This is
controlled by pin provided as EA
b) Internal RAM
The 8051 have a bank of 128 bytes of internal RAM. The internal RAM is found
on-chip. So it is the fastest Ram available. And also it is most flexible in terms of reading
and writing. Internal Ram is volatile, so when 8051 is reset, this memory is cleared. 128
bytes of internal memory are subdivided. The first 32 bytes are divided into 4 register
banks. Each bank contains 8 registers. Internal RAM also contains 128 bits, which are
addressed from 20h to 2Fh. These bits are bit addressed i.e. each individual bit of a byte
can be addressed by the user. They are numbered 00h to 7Fh. The user may make use of
these variables with commands such as SETB and CLR.
Special function registers are the areas of memory that control specific
functionality of the 8051 micro controller.
a) Accumulator (0E0h)
As its name suggests, it is used to accumulate the results of large no of
instructions. It can hold 8 bit values.
B) B register (0F0h)
The B register is very similar to accumulator. It may hold 8-bit value. The b
register is only used by MUL AB and DIV AB instructions. In MUL AB the higher byte
29
of the product gets stored in B register. In div AB the quotient gets stored in B with the
remainder in A.
d) Data pointer
The SFRs DPL and DPH work together work together to represent a 16-bit value
called the data pointer. The data pointer is used in operations regarding external RAM
and some instructions code memory. It is a 16-bit SFR and also an addressable SFR.
e) Program counter
The program counter is a 16 bit register, which contains the 2 byte address, which
tells the 8051 where the next instruction to execute to be found in memory. When the
8051 is initialized PC starts at 0000h. And is incremented each time an instruction is
executes. It is not addressable SFR.
30
The timer control SFR is used to configure and modify the way in which the
8051’s two timers operate. This SFR controls whether each of the two timers is running
or stopped and contains a flag to indicate that each timer has overflowed. Additionally,
some non-timer related bits are located in TCON SFR. These bits are used to configure
the way in which the external interrupt flags are activated, which are set when an
external interrupt occurs.
31
Configurable is how and when they increment in value.
32
bit is used to enable or disable all the interrupts. Thus, if the high bit of IE is 0 all
interrupts are disabled regardless of whether an individual interrupt is enabled by setting
a lower bit.
33
other is read only and holds received data from external sources via RXD. Both mutually
exclusive registers use address 99h.
I/O ports:
One major feature of a microcontroller is the versatility built into the input/output
(I/O) circuits that connect the 8051 to the outside world. The main constraint that limits
numerous functions is the number of pins available in the 8051 circuit. The DIP had 40
pins and the success of the design depends on the flexibility incorporated into use of
these pins. For this reason, 24 of the pins may each used for one of the two entirely
different functions which depend, first, on what is physically connected to it and, then, on
what software programs are used to “program” the pins.
PORT 0
Port 0 pins may serve as inputs, outputs, or, when used together, as a bi directional
low-order address and data bus for external memory. To configure a pin as input, 1 must
be written into the corresponding port 0 latch by the program. When used for interfacing
with the external memory, the lower byte of address is first sent via PORT0, latched using
Address latch enable (ALE) pulse and then the bus is turned around to become the data
bus for external memory.
PORT 1
Port 1 is exclusively used for input/output operations. PORT 1 pins have no dual
function. When a pin is to be configured as input, 1 is to be written into the corresponding
Port 1 latch.
PORT 2
Port 2 maybe used as an input/output port. It may also be used to supply a high –
order address byte in conjunction with Port 0 low-order byte to address external memory.
34
Port 2 pins are momentarily changed by the address control signals when supplying the
high byte a 16-bit address. Port 2 latches remain stable when external memory is
addressed, as they do not have to be turned around (set to 1) for data input as in the case
for Port 0.
PORT 3
Port 3 may be used to input /output port. The input and output functions can be
programmed under the control of the P3 latches or under the control of various special
function registers. Unlike Port 0 and Port 2, which can have external addressing functions
and change all eight-port b se, each pin of port 3 maybe individually programmed to be
used as I/O or as one of the alternate functions. The Port 3 alternate uses are:
TIMERS
35
On-chip timing/counting facility has proved the capabilities of the microcontroller
for implementing the real time application. These includes pulse counting, frequency
measurement, pulse width measurement, baud rate generation, etc,. Having sufficient
number of timer/counters may be a need in a certain design application. The 8051 has
two timers/counters. They can be used either as timers to generate a time delay or as
counters to count events happening outside the microcontroller. Let discuss how these
timers are used to generate time delays and we will also discuss how they are been used
as event counters.
The 8051 has timers: Timer 0 and Timer1.they can be used either as timers or as
event counters. Let us first discuss about the timers’ registers and how to program the
timers to generate time delays.
Both Timer 0 and Timer 1 are 16 bits wide. Since the 8051 has an 8-bit
architecture, each 16-bit timer is accessed as two separate registers of low byte and high
byte.
TIMER 0 REGISTERS
The 16-bit register of Timer 0 is accessed as low byte and high byte. the low
byte register is called TL0(Timer 0 low byte)and the high byte register is referred to as
TH0(Timer 0 high byte).These register can be accessed like any other register, such as
A,B,R0,R1,R2,etc.for example, the instruction ”MOV TL0, #4F”moves the value 4FH
into TL0,the low byte of Timer 0.These registers can also be read like any other register.
36
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
TH0 TL0
TIMER 1 REGISTERS
Timer 1 is also 16-bit register is split into two bytes, referred to as TL1 (Timer
1 low byte) and TH1(Timer 1 high byte).these registers are accessible n the same way as
the register of Timer 0.
Both timers 0 and 1 use the same register, called TMOD, to set the various timer
operation modes. TMOD is an 8-bit register in which the lower 4 bits are set aside for
Timer 0 and the upper 4 bits for Timer 1.in each case; the lower 2 bits are used to set the
timer mode and the upper 2 bits to specify the operation.
37
MODES:
M1, M0:
M0 and M1 are used to select the timer mode. There are three modes: 0, 1, 2.Mode 0 is
a 13-bit timer, mode 1 is a 16-bit timer, and mode 2 is an 8-bit timer. We will concentrate
on modes 1 and 2 since they are the ones used most widely. we will soon describe the
characteristics of these modes, after describing the reset of the TMOD register.
38
M1 M0 MODE Operating Mode
0 0 0 13-bit timer mode
8-bit timer/counter THx with TLx as
5-bit prescaler.
0 1 1 16-bit timer mode
16-bit timer/counters THx with TLx are
cascaded; there is no prescaler
1 0 2 8-bit auto reload
8-bit auto reload timer/counter;THx
Holds a value that is to be reloaded into
TLx each time it overflows.
1 1 3 Split timer mode.
TMOD Register
C/T (clock/timer):
This bit in the TMOD register is used to decide whether the timer is used as a delay
generator or an event counter. If C/T=0, it is used as a timer for time delay generation.
The clock source for the time delay is the crystal frequency of the 8051.this section is
concerned with this choice. The timer’s use as an event counter is discussed in the next
section.
EX: Find the values of TMOD to operate as timers in the following modes.
(a) Mode 1 Timer 1
(b) Mode 2 Timer 0.Mode 2 Timer 1
(c) Mode 0 Timer 1
Solution:
39
(a)TMOD is 00010000 = 10H
The gate control bit and C/T bit are made 0, and the unused timer(Timer 0 bit is also 0)
(b) TMOD is 01010010=52H
(c) TMOD is 00000000H = 00H
Note: 8051 Timers use 1/12 of XTAL frequency, regardless of machine cycle time.
As you know, every timer needs a clock pulse to tick. What is the source of the clock
pulse for the 8051 timers? If C/T=0, the crystal frequency attached to the 8051 is the
source of the clock for the timer. This means that the size of the crystal frequency
attached to the 8051 also decides the speed at which the 8051 timer ticks. The frequency
for the timer is always 1/12th the frequency of the crystal attached to the 8051.
Although various 8051-based systems have an XTAL frequency of 10MHz,we will
concentrate on the XTAL frequency of 11.0592MHz.the reason behind such an odd
number has to do with the baud rate for serial communication of the 8051.XTAL
=11.0592MHz allows the 8051 system to communicate with the IBM PC with no errors.
Gate
The other bit of the TMOD register id the GATE bit. Notice in the TMOD register in the
below example figure that both Timers 0 and 1 have the GATE bit. What is its purpose?
Every timer has a means of starting and stopping. Some timers do this by software, some
by hardware, and some have both software and hardware controls. the timers in the 8051
have is achieved by the instructions “SETB TR1” and “CLR TR1” for Timer 1,and
“SETB TR0” and “CLR TR0” for Timer0.the SETB instruction starts it, and it is stopped
by the CLR instruction. These instructions start and stop the timers as long as GATE =0
40
in the TMOD register. The hardware way of starting and stopping the timer by an
external source GATE =0, meaning that no external hardware is needed to start and stop
the timers. in using software to start and stop the timer where GATE=0,all we need are
the instructions “SETB TRx” and “CLR TRx”.
Now that we have this basic understanding of the role of the TMOD register, we will
look at the timer’s modes and how they are programmed to create a time delay. Because
modes 1 and 2 are so widely used, we describe each of them in detail.
EX:
How are timers 0 and 1 started and stopped by instruction?
Solution:
The timers are started by using instructions to set timer start bits TR0 and
TR1,which are called timer run control bits. They can be cleared by clearing these bits.
When a timer counts to its maximum value, it sets a flag TF0 or TF1.at this point, it is
necessary to know more about the bits TF and TR for timers 0 and 1.while TMOD
controls the timer modes, another register called the TCON controls the timer/counter
operations. The lower four bits of TCON cater to interrupt functions, but the upper four
bits are for timer operations. The details of the TCON register are shown below.
MSB LSB
41
TCON.6 TR1 Timer 1 run control bit
TCON.5 TF0 Timer 0 overflows flag
TCON.4 TR0 Timer 0 run control bit
Some assemblers don’t allow the use of TF0, TR0, etc.in programs, but instead need the
use of these as bits of TON. For example, TF1 is TCON.7 and TR1 is TCON.6.
Mode 1 programming
XTAL
oscillat /12 TH TL TF
or
. _
42
C/T =0 TR TF goes high overflow
When FFFF—0 flag
1. Load the TMOD value register indicating which timer (Timer 0 or Timer 1) is to
be used and which timer mode (0 or 1) is selected.
2. Load register TL and TH with initial count values.
43
3. Start the timer.
4. Keep monitoring the timer flag (TF) with the “JNB TFx, target” instruction to see
if it is raised. Get out of the loop when TF becomes high.
5. Stop the timer.
6. Clear the TF flag for the next round
7. Go back to Step 2 to load TH and TL again.
EX: In the following program, we are creating a square wave of 50% duty cycle (with
equal portion high and low) on the P1.5 bit. Timer 0 is used to generate the time delay.
Analyze the program.
Solution:
DELAY:
SETB TR0 ; start Timer 0
AGAIN: JNB TF0, AGAIN ; monitor Timer 0 flag until
; It rolls over
CLR TR0 ; stop Timer 0
CLR TF0 ; clear Timer 0 flag
RET
44
Finding values to be loaded into the timer
Assuming that we know the amount of timer delay we need, the question is how to find
the values needed for the TH, TL registers. To calculate the values to be loaded into the
TL and TH registers.
Size of the time delay depends on two factors; (a) the crystal frequency and (b) the
timer’s 16-bit register in mode 1.both of these factors are beyond the control of the 8051
programmer. We saw earlier that the largest time delay is achieved by making both TH
and TL zero. what if that is not enough?
See the below example.
Ex: Assuming XTAL = 2MHz,write a program to generate a pulse train 2 seconds period
on pin P2.4.USse Timer 1 in mode 1.
Solution:
MOV TMOD, #10H ; Timer 1, mode 1
REPT: MOV R0, #28 ; counter for multiple delays
CPL P2.4 ; complement P2.4
BACK: MOV TL1, #00H ; load count value in TL1
MOV TH1, #00H ; load count value in th1
SETB TR1 ; start timer
AGAIN: JNB TF1, AGAIN ; stay until timer roller over
45
CLR TR1 ; stop timer
CLR TF1 ; clear timer flag
DJNZ R0, BACK ; if R0 is not zero, reload timer
SJMP REPT ; repeat for continuous pulse
generation
Mode 0
Mode 0 is exactly like mode 1 except that it is a 13-bit timer instead of 16-bit.the 13-bit
counter can hold values between 0000 to 1FFFH in TH-TL. Therefore, when the timer
reaches its maximum of 1FFH, it rolls over to 0000, and TF is raised.
46
Mode 2 programming
Overflow
flag
XTAL
Oscillator /12 TL TF
TH
TR TF goes high
when FF---0
47
It must be emphasized that mode 2 is an 8-bit timer. However, it has an auto-
reloading capability. In auto-reload TH is loaded with the initial count and a copy of it
is given to TL. This reloading leaves TH unchanged, still holding a copy of the
original value. This mode has many applications, including setting the baud rate in
serial communication.
To generate a time delay using the timer’s mode 2 take the following steps.
48
1. Load the TMOD value register indicting which timer (Timer 0 or Timer 1) is to be
used, and select the timer mode(mode 2).
2. Load the TH registers with the initial count value.
3. start the timer
4. Keep monitoring the timer flag (TF) with the “JNB TFx, target” instruction to see
whether it is raised. get out of the loop when TF goes high.
5. clear the TF flag
6. Go back to step 4, since mode 2 is auto-reload.
SERIAL COMMUNICATION:
Computers can transfer data in two ways: parallel and serial. In parallel
data transfers, often 8 or more lines (wire conductors) are used to transfer data to a device
that is only a few feet away. Examples of parallel transfers’ ae printers and hard disks;
each uses cables with many wire strips. Although in such cases a lot of data can be
transferred in a short amount of time by using many wires in parallel, the distance cannot
be great. To transfer to a device located many meters away, the serial method is used. In
serial communication, the data is sent one bit at a time, in contrast to parallel
communication, in which the data is sent a byte or more at a time. Serial communication
of the 8051 is the topic of this chapter. The 8051 has serial communication capability
built into it, there by making possible fast data transfer using only a few wires.
If data is to be transferred on the telephone line, it must be converted from 0s and
1s to audio tones, which are sinusoidal-shaped signals. This conversion is performed by
a peripheral device called a modem, which stands for “modulator/demodulator.”
Serial data communication uses two methods, asynchronous and synchronous.
The synchronous method transfers a block of data at a time, while the asynchronous
method transfers a single byte at a time.
In data transmission if the data can be transmitted and received, it is a duplex
transmission. This is in contrast to simplex transmissions such as with printers, in which
the computer only sends data. Duplex transmissions can be half or full duplex,
depending on whether or not the data transfer can be simultaneous. If data is transmitted
49
one way at a time, it is referred to as half duplex. If the data can go both ways at the
same time, it is full duplex. Of course, full duplex requires two wire conductors for the
data lines, one for transmission and one for reception, in order to transfer and receiv e
data simultaneously.
Asynchronous serial communication and data framing
The data coming in at the receiving end of the data line in a serial data transfer is
all 0s and 1s; it is difficult to make sense of the data unless the sender and receiver agree
on a set of rules, a protocol, on how the data is packed, how many bits constitute a
character, and when the data begins and ends.
Start and stop bits
Asynchronous serial data communication is widely used for character-oriented
transmissions, while block-oriented data transfers use the synchronous method. In the
asynchronous method, each character is placed between start and stop bits. This is called
framing. In the data framing for asynchronous communications, the data, such as ASCII
characters, are packed between a start bit and a stop bit. The start bit is always one bit,
but the stop bit can be one or two bits. The start bit is always a 0 (low) and the stop bit
(s) is 1 (high).
Data transfer rate
The rate of data transfer in serial data communication is stated in bps (bits per
second). Another widely used terminology for bps is baud rate. However, the baud and
bps rates are not necessarily equal. This is due to the fact that baud rate is the modem
terminology and is defined as the number of signal changes per second. In modems a
single change of signal, sometimes transfers several bits of data. As far as the conductor
wire is concerned, the baud rate and bps are the same, and for this reason we use the bps
and baud interchangeably.
The data transfer rate of given computer system depends on communication ports
incorporated into that system. For example, the early IBMPC/XT could transfer data at
the rate of 100 to 9600 bps. In recent years, however, Pentium based PCS transfer data at
rates as high as 56K bps. It must be noted that in asynchronous serial data
communication, the baud rate is generally limited to 100,000bps.
RS232 Standards
50
To allow compatibility among data communication equipment made by various
manufacturers, an interfacing standard called RS232 was set by the Electronics Industries
Association (EIA) in 1960. In 1963 it was modified and called RS232A. RS232B AND
RS232C were issued in 1965 and 1969, respectively. Today, RS232 is the most widely
used serial I/O interfacing standard. This standard is used in PCs and numerous types of
equipment. However, since the standard was set long before the advert of the TTL logic
family, its input and output voltage levels are not TTL compatible. In RS232, a 1 is
represented by -3 to -25V, while a 0 bit is +3 to +25V, making -3 to +3 undefined. For
this reason, to connect any RS232 to a microcontroller system we must use voltage
converters such as MAX232 to convert the TTL logic levels to the RS232 voltage levels,
and vice versa. MAX232 IC chips are commonly referred to as line drivers.
RS232 pins
RS232 cable, commonly referred to as the DB-25 connector. In labeling, DB-25P
refers to the plug connector (male) and DB-25S is for the socket connector(female).
Since not all the pins are used in PC cables, IBM introduced the DB-9 Version of the
serial I/O standard, which uses 9 pins only, as shown in table.
DB-9 pin connector
12345
6789
Pin Functions:
Pin Description
1 Data carrier detect (DCD)
2 Received data (RXD)
3 Transmitted data (TXD)
4 Data terminal ready(DTR)
5 Signal ground (GND)
6 Data set ready (DSR)
7 Request to send (RTS)
8 Clear to send (CTS)
9 Ring indicator (RI)
51
Note: DCD, DSR, RTS and CTS are active low pins.
The method used by RS-232 for communication allows for a simple connection of three
lines: Tx, Rx, and Ground. The three essential signals for 2 way RS-232
52
Baud rate in the 8051
The 8051 transfers and receives data serially at many different baud rates. The
baud rate in the 8051 is programmable. The is done with the help of Timer1. The 8051
divides the crystal frequency by 12 to get the machine cycle frequency. In the case of
XTAL=11.0592MHZ, the machine cycle frequency is 921.6 KHz
(11.0592MHz/12=921.6KHz). the 8051’s serial communication UART circuitry divides
the machine cycle frequency of 921.6khz divided by 32 once more before it is used by
Timer 1 to set the Baud rate. Therefore, 921.6 kHz divided by 32 gives 28,800 Hz. This
is the number well use to find the Timer 1 value to set baud rate.
Baud rate TH1(Decimal) TH1(Hex)
9600 -3 FD
4800 -6 FA
2400 -12 F4
1200 -24 E8
NOTE: XTAL=11...592MHz
SBUF register
SBUF is an 8-bit register used solely for serial communication in the 8051. for a
byte of data to be transferred via the TXD line, it must be placed in the SBUF register.
Similarly, SBUF holds the byte of data when it is received by the 8051’s RXD line.
SBUF can be accessed like any other register in the 8051. Look at the following the
examples of how this register is accessed.
MOV SBUF, #’D’ ; load SBUF=44h, ASCII for ‘D’
MOV SBUF, A; copy accumulator into SBUF
53
MOV A, SBUF ; copy SBUF into accumulator
The moment a byte is written into SBUF, it is framed with the start and stop bits
and transferred serially via the TXD pin. Similarly, when the bits are received serially via
RXD, the 8051 defames it by eliminating the stop and start bits, making a byte out of the
data received, and then placing it in the SBUF.
SM0, SM1
54
SM0 and SM1 are D7 and D6 of the SCON register, respectively. These two bits
determine the framing of data by specifying the number of bits per character and the start
and stop bits. They take the following combinations.
Of the 4 serial modes, only mode 1 is of interest to us. In the SCON register,
when serial mode 1 is chosen, the data framing is 8 bits, 1 stop bit, and 1 start bit, which
makes it compatible with the COM port of IBM/compatible PCs. More importantly,
serial mode 1 allows the baud rate to be variable and is set by Timer 1 of the 8051. In
serial mode 1, for each character a total of 10 bits are transferred, where the first bit is the
start bit, followed by 8 bits of data, and finally 1 stop bit.
MODE 0
In mode 0, the data are transferred through the RXD pin, while clock pulses appear on the
TXD pin. The bout rate is fixed at 1/12 the quartz oscillator frequency. On transmit, the
least significant bit (LSB bit) is being sent/received first. (received).
TRANSMIT
Data transmission in form of pulse train automatically starts on the pin RXD at the
moment the data has been written to the SBUF register.In fact, this process starts after
any instruction being performed on this register. Upon all 8 bits have been sent, the bit TI
in the SCON register is automatically set.
55
RECEIVE
Starts data receiving through the pin RXD once two necessary conditions are met: bit
REN=1 and RI=0 (both bits reside in the SCON register). Upon 8 bits have been
received, the bit RI (register SCON) is automatically set, which indicates that one byte is
received.
Since, there are no START and STOP bits or any other bit except data from the SBUF
register, this mode is mainly used on shorter distance where the noise level is minimal
and where operating rate is important. A typical example for this is I/O port extension by
adding cheap IC circuit ( shift registers 74HC595, 74HC597 and similar).
56
Mode 1
In Mode1 10 bits are transmitted through TXD or received through RXD in the following
manner: a START bit (always 0), 8 data bits (LSB first) and a STOP bit (always 1) last.
The START bit is not registered in this pulse train. Its purpose is to start data receiving
mechanism. On receive the STOP bit is automatically written to the RB8 bit in the SCON
register.
TRANSMIT
A sequence for data transmission via serial communication is automatically started upon
the data has been written to the SBUF register. End of 1 byte transmission is indicated by
setting the TI bit in the SCON register.
57
RECEIVE
Receiving starts as soon as the START bit (logic zero (0)) appears on the pin RXD. The
condition is that bit REN=1and bit RI=0. Both of them are stored in the SCON register.
The RI bit is automatically set upon receiving has been completed.
The Baud rate in this mode is determined by the timer 1 overflow time.
MODE 2
SM2
SM2 is the D5 bit of the SCON register. This bit enables the multiprocessing
capability of the 8051. For our applications, we will make SM2=0 since we are not using
the 8051 in a multi processor environment.
REN
The REN (receive enable) bit is D4 of the SCON register. The REN bit is also
referred to as SCON.4 since SCON is a bit-addressable register. When the REN bit is
high, it allows the 8051 to receive data on the RXD pin of the 8051. As a result if we
want the 8051 to both transfer and receive data, REN must be set to 1. By making
REN=0, the receiver is disabled. Making REN=1 or REN=0 can be achieved by the
instructions “SETB SCON.4” and “CLR SCON.4”, respectively. Notice that these
instructions use the bit-addressable features of the register SCON. This bit can be used to
block any serial data reception and is an extremely important in the SCON register.
58
TB8
TB8 (transfer bit 8) is bit D3 of SCON. It is used for serial modes 2 and 3. we
make TB8=0 since it is not used in our applications.
RB8
RB8 (receive bit 8) is bit D2 of the SCON register. In serial mode 1, this bit gets
a copy of the stop bit when an 8-bit data is received. This is (as is the case for TB8) is
rarely used anymore. In all our applications we will make RB8=0. Like TB8, the RB8
bit is also used in serial modes 2 and 3.
TRANSMIT
59
RECEIVE
Mode 3
Mode 3 is the same as Mode 2 except the baud rate. In Mode 3 is variable and can be
selected.
60
FLOW CHART:
TX Loop:
RX Loop:
61
BAUD RATE CALCULATION:
Divided by X box can be replaced with T1 timer so that by changing the value of timer
we can obtain the required baud rate.
Note: Assuming 8-bit Auto reload mode and 8-bit variable baud rate modes.
Doubling the baud rate in the 8051:
There are two ways to increase the baud rate to data transfer in the 8051.
1. Use a higher- frequency crystal.
2. Change a bit in the PCON register, shown below.
Option1 is not feasible in many situations since the system crystal is fixed. More
62
Importantly, it is not feasible because the new crystal may not be compatible with the
IBM PC serial COM port’s baud rate. Therefore, we will explore option2. there is a
software way to double the baud rate of the 8051 while the crystal frequency is fixed.
This is done with the register called PCON (power control). The PCON register is an 8-
bit register. Of the 8 bits, some are unused, and some are used for the power control
capability of the 8051. The bit that is used for the serial communication is D7, the SMOD
(serial mode) bit. When the 8051 is powered up, D7 (SMOD) of this PCON register is
zero. We can set it to high by software and thereby double the baud rate. The following
sequence of instructions must be used to set high D7 of PCON, since it is not a bit-
addressable register:
MOV A, PCON ; place a copy a of PCON in ACC
SETB ACC.7 ; make D7=1
MOV PCON, A ; changing any other bits
To see how the baud rate is double with this method, we show the role of the
SMOD bit (D7 bit of the PCON register), which can be 0 or 1. we discuss each case.
63
Machine cycle freq. = 11.0592 MHz / 12 = 921.6 KHz
And
921.6 KHz / 16 = 57,600 Hz since SMOD = 1
This is the frequency used by Timer 1 to set the baud rate.
Table: Baud Rate comparison for SMOD = 0 and SMOD = 1
TH1 (Decimal) (Hex) SMOD = 0 SMOD = 1
-3 FD 9,600 19,200
-6 FA 4,800 9,600
-12 F4 2,400 4,800
-24 E8 1,200 2,400
Note: XTAL=11.0592 MHz.
Table: shows that the values loaded into TH1 are the same for both cases; however, the
baud rates are doubled when SMOD=1.
INTERRUPTS:
Interrupts are hardware signals that are used to determine conditions that exist in
external and internal circuits. Any interrupt can cause the 8051 to perform a hardware call
to an interrupt –handling subroutine that is located at a predetermined absolute address in
the program memory.
Five interrupts are provided in the 8051. Three of these are generated automatically
by the internal operations: Timer flag 0, Timer Flag 1, and the serial port interrupt (RI or
TI) Two interrupts are triggered by external signals provided by the circuitry that is
connected to the pins INTO 0 and INTO1. The interrupts maybe enable or disabled, given
priority or otherwise controlled by altering the bits in the Interrupt Enabled (IE) register,
Interrupt Priority (IP) register, and the Timer Control (TCON) register. . These interrupts
are mask able i.e. they can be disabled. Reset is a non maskable interrupt which has the
highest priority. It is generated when a high is applied to the reset pin. Upon reset, the
registers are loaded with the default values.
Each interrupt source causes the program to do store the address in PC onto the
stack and causes a hardware call to one of the dedicated addresses in the program
memory. The appropriate memory locations for each for each interrupt are as follows:
64
Interrupt Address
RESET 0000
IE0 (External interrupt 0) 0003
TF0 (Timer 0 interrupt) 000B
IE1 (External interrupt 1) 0013
TF1 (Timer 1 interrupt) 001B
SERIAL 0023
RELAY:
65
A relay is an electrical switch that opens and closes under the control of another electrical
circuit. In the original form, the switch is operated by an electromagnet to open or close
one or many sets of contacts. It was invented by Joseph Henry in 1835. Because a relay is
able to control an output circuit of higher power than the input circuit, it can be
considered to be, in a broad sense, a form of an electrical amplifier.
Operation
When a current flows through the coil, the resulting magnetic field attracts an armature
that is mechanically linked to a moving contact. The movement either makes or breaks a
connection with a fixed contact. When the current to the coil is switched off, the armature
is returned by a force approximately half as strong as the magnetic force to its relaxed
position. Usually this is a spring, but gravity is also used commonly in industrial motor
starters. Most relays are manufactured to operate quickly. In a low voltage application,
this is to reduce noise. In a high voltage or high current application, this is to reduce
arcing.
If the coil is energized with DC, a diode is frequently installed across the coil, to dissipate
the energy from the collapsing magnetic field at deactivation, which would otherwise
generate a spike of voltage and might cause damage to circuit components. Some
automotive relays already include that diode inside the relay case. Alternatively a contact
protection network, consisting of a capacitor and resistor in series, may absorb the surge.
If the coil is designed to be energized with AC, a small copper ring can be crimped to the
end of the solenoid. This "shading ring" creates a small out-of-phase current, which
increases the minimum pull on the armature during the AC cycle.[1]
By analogy with the functions of the original electromagnetic device, a solid-state relay is
made with a thyristor or other solid-state switching device. To achieve electrical isolation
an optocoupler can be used which is a light-emitting diode (LED) coupled with a photo
transistor.
66
Types of relay
Latching relay
A latching relay has two relaxed states (bistable). These are also called 'keep' relays.
When the current is switched off, the relay remains in its last state. This is achieved with
a solenoid operating a ratchet and cam mechanism, or by having two opposing coils with
an over-center spring or permanent magnet to hold the armature and contacts in position
while the coil is relaxed, or with a remnant core. In the ratchet and cam example, the first
pulse to the coil turns the relay on and the second pulse turns it off. In the two coil
example, a pulse to one coil turns the relay on and a pulse to the opposite coil turns the
relay off. This type of relay has the advantage that it consumes power only for an instant,
while it is being switched, and it retains its last setting across a power outage.
Reed relay
A reed relay has a set of contacts inside a vacuum or inert gas filled glass tube, which
protects the contacts against atmospheric corrosion. The contacts are closed by a
magnetic field generated when current passes through a coil around the glass tube. Reed
relays are capable of faster switching speeds than larger types of relays, but have low
switch current and voltage ratings. See also reed switch.
67
Mercury-wetted relay
A mercury-wetted reed relay is a form of reed relay in which the contacts are wetted
with mercury. Such relays are used to switch low-voltage signals (one volt or less)
because of its low contact resistance, or for high-speed counting and timing applications
where the mercury eliminates contact bounce. Mercury wetted relays are position-
sensitive and must be mounted vertically to work properly. Because of the toxicity and
expense of liquid mercury, these relays are rarely specified for new equipment. See also
mercury switch.
Polarized relay
A Polarized Relay placed the armature between the poles of a permanent magnet to
increase sensitivity. Polarized relays were used in middle 20th Century telephone
exchanges to detect faint pulses and correct telegraphic distortion. The poles were on
screws, so a technician could first adjust them for maximum sensitivity and then apply a
bias spring to set the critical current that would operate the relay.
A machine tool relay is a type standardized for industrial control of machine tools,
transfer machines, and other sequential control. They are characterized by a large number
of contacts (sometimes extendable in the field) which are easily converted from
normally-open to normally-closed status, easily replaceable coils, and a form factor that
allows compactly installing many relays in a control panel. Although such relays once
were the backbone of automation in such industries as automobile assembly, the
programmable logic controller mostly displaced the machine tool relay from sequential
control applications.
Contactor relay
A contactor is a very heavy-duty relay used for switching electric motors and lighting
loads. With high current, the contacts are made with pure silver. The unavoidable arcing
68
causes the contacts to oxidize and silver oxide is still a good conductor. Such devices are
often used for motor starters. A motor starter is a contactor with overload protection
devices attached. The overload sensing devices are a form of heat operated relay where a
coil heats a bi-metal strip, or where a solder pot melts, releasing a spring to operate
auxiliary contacts. These auxiliary contacts are in series with the coil. If the overload
senses excess current in the load, the coil is de-energized. Contactor relays can be
extremely loud to operate, making them unfit for use where noise is a chief concern.
A solid state contactor is a very heavy-duty solid state relay, including the necessary
heat sink, used for switching electric heaters, small electric motors and lighting loads;
where frequent on/off cycles are required. There are no moving parts to wear out and
there is no contact bounce due to vibration. They are activated by AC control signals or
DC control signals from Programmable logic controller (PLCs), PCs, Transistor-
transistor logic (TTL) sources, or other microprocessor controls.
Buchholz relay
A Buchholz relay is a safety device sensing the accumulation of gas in large oil-filled
transformers, which will alarm on slow accumulation of gas or shut down the transformer
if gas is produced rapidly in the transformer oil.
69
Forced-guided contacts relay
A forced-guided contacts relay has relay contacts that are mechanically linked together,
so that when the relay coil is energized or de-energized, all of the linked contacts move
together. If one set of contacts in the relay becomes immobilized, no other contact of the
same relay will be able to move. The function of forced-guided contacts is to enable the
safety circuit to check the status of the relay. Forced-guided contacts are also known as
"positive-guided contacts", "captive contacts", "locked contacts", or "safety relays".
Solid-state relay
A solid state relay (SSR) is a solid state electronic component that provides a similar
function to an electromechanical relay but does not have any moving components,
increasing long-term reliability. With early SSR's, the tradeoff came from the fact that
every transistor has a small voltage drop across it. This collective voltage drop limited the
amount of current a given SSR could handle. As transistors improved, higher current
SSR's, able to handle 100 to 1,200 amps, have become commercially available.
Compared to electromagnetic relays, they may be falsely triggered by transients.
One type of electric motor overload protection relay is operated by a heating element in
series with the electric motor . The heat generated by the motor current operates a bi-
metal strip or melts solder, releasing a spring to operate contacts. Where the overload
70
relay is exposed to the same environment as the motor, a useful though crude
compensation for motor ambient temperature is provided.
Circuit symbols of relays. "C" denotes the common terminal in SPDT and DPDT types.
Since relays are switches, the terminology applied to switches is also applied to relays. A
relay will switch one or more poles, each of whose contacts can be thrown by energizing
the coil in one of three ways:
Normally-open (NO) contacts connect the circuit when the relay is activated; the
circuit is disconnected when the relay is inactive. It is also called a Form A contact or
"make" contact.
71
Normally-closed (NC) contacts disconnect the circuit when the relay is activated;
the circuit is connected when the relay is inactive. It is also called a Form B contact or
"break" contact.
Change-over, or double-throw, contacts control two circuits: one normally-open
contact and one normally-closed contact with a common terminal. It is also called a
Form C contact or "transfer" contact. If this type of contact utilizes a "make before
break" functionality, then it is called a Form D contact.
SPST - Single Pole Single Throw. These have two terminals which can be
connected or disconnected. Including two for the coil, such a relay has four terminals in
total. It is ambiguous whether the pole is normally open or normally closed. The
terminology "SPNO" and "SPNC" is sometimes used to resolve the ambiguity.
SPDT - Single Pole Double Throw. A common terminal connects to either of two
others. Including two for the coil, such a relay has five terminals in total.
DPST - Double Pole Single Throw. These have two pairs of terminals. Equivalent
to two SPST switches or relays actuated by a single coil. Including two for the coil, such
a relay has six terminals in total. It is ambiguous whether the poles are normally open,
normally closed, or one of each.
72
QPDT - Quadruple Pole Double Throw. Often referred to as Quad Pole Double
Throw, or 4PDT. These have four rows of change-over terminals. Equivalent to four
SPDT switches or relays actuated by a single coil, or two DPDT relays. In total, fourteen
terminals including the coil.
Applications
73
parallel. The change-over or Form C contacts perform the XOR (exclusive or) function.
Similar functions for NAND and NOR are accomplished using NC contacts. The Ladder
programming language is often used for designing relay logic networks.
o Early computing. Before vacuum tubes and transistors, relays were used as
logical elements in digital computers. See ARRA (computer), Harvard Mark II, Zuse Z2,
and Zuse Z3.
o Safety-critical logic. Because relays are much more resistant than
semiconductors to nuclear radiation, they are widely used in safety-critical logic, such as
the control panels of radioactive waste-handling machinery.
to perform time delay functions. Relays can be modified to delay opening or delay
closing a set of contacts. A very short (a fraction of a second) delay would use a copper
disk between the armature and moving blade assembly. Current flowing in the disk
maintains magnetic field for a short time, lengthening release time. For a slightly longer
(up to a minute) delay, a dashpot is used. A dashpot is a piston filled with fluid that is
allowed to escape slowly. The time period can be varied by increasing or decreasing the
flow rate. For longer time periods, a mechanical clockwork timer is installed.
A large relay with two coils and many sets of contacts, used in an old telephone switching
system.
Several 30-contact relays in "Connector" circuits in mid 20th century 1XB switch and
5XB switch telephone exchanges; cover removed on one
74
Selection of an appropriate relay for a particular application requires evaluation of many
different factors:
75
Accessories such as timers, auxiliary contacts, pilot lamps, test buttons
Regulatory approvals
Stray magnetic linkage between coils of adjacent relays on a printed circuit board.
Protective relay
A protective relay is a complex electromechanical apparatus, often with more than one
coil, designed to calculate operating conditions on an electrical circuit and trip circuit
breakers when a fault was found. Unlike switching type relays with fixed and usually ill-
defined operating voltage thresholds and operating times, protective relays had well-
established, selectable, time/current (or other operating parameter) curves. Such relays
were very elaborate, using arrays of induction disks, shaded-pole magnets, operating and
restraint coils, solenoid-type operators, telephone-relay style contacts, and phase-shifting
networks to allow the relay to respond to such conditions as over-current, over-voltage,
reverse power flow, over- and under- frequency, and even distance relays that would trip
for faults up to a certain distance away from a substation but not beyond that point. An
important transmission line or generator unit would have had cubicles dedicated to
protection, with a score of individual electromechanical devices. The various protective
functions available on a given relay are denoted by standard ANSI Device Numbers. For
example, a relay including function 51 would be a timed overcurrent protective relay.
Design and theory of these protective devices is an important part of the education of an
electrical engineer who specializes in power systems. Today these devices are nearly
entirely replaced (in new designs) with microprocessor-based instruments (numerical
relays) that emulate their electromechanical ancestors with great precision and
convenience in application. By combining several functions in one case, numerical relays
also save capital cost and maintenance cost over electromechanical relays. However, due
76
to their very long life span, tens of thousands of these "silent sentinels" are still protecting
transmission lines and electrical apparatus all over the world.
An "Over current Relay" is a type of protective relay which operates when the load
current exceeds a preset value. The ANSI Device Designation Number is 50 for an
Instantaneous over Current (IOC), 51 for a Time over Current (TOC). In a typical
application the over current relay is used for over current protection, connected to a
current transformer and calibrated to operate at or above a specific current level. When
the relay operates, one or more contacts will operate and energize a trip coil in a Circuit
Breaker and trip (open) the Circuit Breaker.
Distance relay
It is a protective relay used to protect power transmission and distribution lines against
different fault types. The relay monitors line impedance by measuring line voltage and
current. Once a fault occurs, the voltage drops to zero and thus the measured impedance
become less than the setting value ``reach``. As a result the relay issues a trip command
77
TRANSFORMER:
A transformer is a device that transfers electrical energy from one circuit to another
through inductively coupled electrical conductors. A changing current in the first circuit
(the primary) creates a changing magnetic field; in turn, this magnetic field induces a
changing voltage in the second circuit (the secondary). By adding a load to the secondary
circuit, one can make current flow in the transformer, thus transferring energy from one
circuit to the other.
The secondary induced voltage VS is scaled from the primary VP by a factor ideally
equal to the ratio of the number of turns of wire in their respective windings:
Transformers are some of the most efficient electrical 'machines', with some large units
able to transfer 99.75% of their input power to their output. Transformers come in a range
of sizes from a thumbnail-sized coupling transformer hidden inside a stage microphone to
huge units weighing hundreds of tons used to interconnect portions of national power
grids. All operate with the same basic principles, though a variety of designs exist to
perform specialized roles throughout home and industry.
Applications
78
but a fraction of the world's electrical power has passed through a series of transformers
by the time it reaches the consumer
Basic principles
The transformer is based on two principles: first, that an electric current can produce a
magnetic field (electromagnetism) and, second, that a changing magnetic field within a
coil of wire induces a voltage across the ends of the coil (electromagnetic induction). By
changing the current in the primary coil, one changes the strength of its magnetic field;
since the changing magnetic field extends into the secondary coil, a voltage is induced
across the secondary.
A simplified transformer design is shown to the left. A current passing through the
primary coil creates a magnetic field. The primary and secondary coils are wrapped
around a core of very high magnetic permeability, such as iron; this ensures that most of
the magnetic field lines produced by the primary current are within the iron and pass
through the secondary coil as well as the primary coil.
Induction law
The voltage induced across the secondary coil may be calculated from Faraday's law of
induction, which states that:
where VS is the instantaneous voltage, NS is the number of turns in the secondary coil
and Φ equals the total magnetic flux through one turn of the coil. If the turns of the coil
are oriented perpendicular to the magnetic field lines, the flux is the product of the
magnetic field strength B and the area A through which it cuts. The area is constant, being
equal to the cross-sectional area of the transformer core, whereas the magnetic field
79
varies with time according to the excitation of the primary. Since the same magnetic flux
passes through both the primary and secondary coils in an ideal transformer,[5] the
instantaneous voltage across the primary winding equals
Taking the ratio of the two equations for VS and VP gives the basic equation[6] for
stepping up or stepping down the voltage
If the secondary coil is attached to a load that allows current to flow, electrical power is
transmitted from the primary circuit to the secondary circuit. Ideally, the transformer is
perfectly efficient; all the incoming energy is transformed from the primary circuit to the
magnetic field and thence to the secondary circuit. If this condition is met, the incoming
electric power must equal the outgoing power
Thus, if the voltage is stepped up (VS > VP), then the current is stepped down (IS < IP)
by the same factor. In practice, most transformers are very efficient (see below), so that
this formula is a good approximation.
The impedance in one circuit is transformed by the square of the turns ratio.[5] For
example, if an impedance ZS is attached across the terminals of the secondary coil, it
appears to the primary circuit to have an impedance of . This relationship is reciprocal, so
that the impedance ZP of the primary circuit appears to the secondary to be .
Detailed operation
80
The simplified description above avoids several complicating factors, in particular the
primary current required to establish a magnetic field in the core, and the contribution to
the field due to current in the secondary circuit.
Models of an ideal transformer typically assume a core of negligible reluctance with two
windings of zero resistance.[7] When a voltage is applied to the primary winding, a small
current flows, driving flux around the magnetic circuit of the core.[7]. The current
required to create the flux is termed the magnetizing current; since the ideal core has been
assumed to have near-zero reluctance, the magnetizing current is negligible, although a
presence is still required to create the magnetic field.
The changing magnetic field induces an electromotive force (EMF) across each winding.
[8] Since the ideal windings have no impedance, they have no associated voltage drop,
and so the voltages VP and VS measured at the terminals of the transformer, are equal to
the corresponding EMFs. The primary EMF, acting as it does in opposition to the primary
voltage, is sometimes termed the "back EMF".[9] This is due to Lenz's law which states
that the induction of EMF would always be such that it will oppose development of any
such change in magnetic field
The AMF Control Panel is a specially designed panel for standby generators.
It consists of a state of the art microcontroller based AMF controller for monitoring,
indicating and controlling the Mains and Generator for AMF operation.
•AUTO
In this mode the AMF controller takes command of the total system operation.
Sequence of operation:
i.] At power ON, if Mains is healthy the Mains contactor is turned ON and load gets
power from Mains.
ii]. If Mains is unhealthy or if the load is above the rated voltage of the transformer; the
controller starts the generator and transfers the load on the generator (In this project we
are using transformer).
81
iii.] If the Mains recover or the load is below the rated voltage, the controller switches the
load back onto Mains and shuts down the generator after cooling time.
•MANUAL
In this mode the starting / stopping of the generator and load ON/OFF can be done
manually from the AMF controller. In this mode if any fault occurs in the generator while
running the AMF controller takes necessary action by indicating alarms and/or tripping
the generator.
•TEST
this mode is used to check the health of the generator. In TEST mode the generator is
started and kept ON for a fixed duration. During this period the AMF controller checks
for any faults in the generator. If any fault is sensed the controller displays the same. If
the generator is found healthy GENSET OK is indicated on the display.
• BYPASS
In BYPASS mode the AMF controller acts just as an indicating instrument. The system is
operated from the external switches provided on the Control Panel. The AMF controller
in case of faults in this mode takes no action.
• HOLD
The LCD display of AMF Controller indicates following parameters in scrolling mode:
82
POWER SUPPLY UNIT
Introduction:
When dealing with electronic circuits, we have to meet the basic requirement of
providing electrical power for them to work. Without that power, your circuit is no more
useful or meaningful than a single raindrop in a hurricane.
The basic purpose of a power supply is to provide one or more fixed voltages to the
working circuit, with sufficient current-handling capacity to maintain the operating
conditions of the circuit. The power source doesn't have to be fancy; the typical hand-
held transistor radio uses a 9-volt battery as its power source. A flashlight uses cells that
are physically much larger, but provide a lower voltage. Major electronic appliances such
as television sets, VCRs, and microwave ovens have electronic circuits built in that take
power from a wall socket and convert it to the form and voltages required by the other
internal circuits of the appliance.
Although each power supply has its own individual specifications and characteristics,
all power supplies have certain characteristics in common. We'll look at the main parts of
a power supply on this page and see how they work together. Then, on subsequent pages,
we'll take a more detailed look at each of the parts we haven't seen before, and explore
the major variations that are commonly used in modern power supplies.
A basic power supply consists of three main sections, as shown in the block
diagram below and to the right. Depending on the requirements for a given power supply,
the sections can be very simple or extremely complex, or even left out altogether in
certain circumstances. Each of the sections serves one or more specific purposes, as
follows:
83
Transformer: In general, the ac line voltage present in your house wiring is not suitable
for electronic circuits. Most circuits require a considerably lower voltage, while a few
require higher voltages. The transformer serves to convert the ac line voltage to a voltage
level more appropriate to the needs of the circuit to be powered. At the same time, the
transformer provides electrical isolation between the ac line and the circuit being
powered, which is an important safety consideration. However, a line transformer is
generally large and heavy, and is rather expensive. Therefore, some power supplies
(notably for PCs) are deliberately designed to operate directly from the ac line without a
line transformer. The output of the transformer is still an ac voltage, but now of an
appropriate magnitude for the circuit to be powered.
Rectifier: The next step is to force current to flow in one direction only, preventing the
alternations that occur in the transformer and the ac line. This process is known as
rectification, and the circuit that accomplishes the task is the rectifier. There are many
different rectifier configurations that may be used according to the requirements of the
circuit. The output of the rectifier is a pulsating dc, which still has some of the variations
from the ac line and transformer.
Filter: The pulsating dc from the rectifier is generally still not suitable to power the
actual load circuit. The pulsations typically vary from 0 volts to the peak output voltage
of the transformer. Therefore, we insert a circuit to store energy during each voltage peak,
and then release it to the load when the rectifier output voltage drops. This circuit is
called a filter, and its job is to reduce the pulses from the rectifier to a much smaller
84
ripple voltage. No filter configuration can be absolutely perfect, but a properly designed
filter will provide a dc output voltage with only a small ac ripple.
Each of the three sections identified above can have a number of variations —
even the transformer, which we covered in an earlier page on transformers. Regardless of
these variations, each section performs its specific task. However, some circuits do the
job more effectively than others, or pick different trade-offs between possible
alternatives. To measure the effectiveness of each circuit, we compare the magnitude of
the remaining ac component, or ripple, with the dc component of the total voltage
appearing at the output of that section. The ratio of ac voltage to dc voltage is known as
the ripple factor. The goal of any power supply design is to reduce the ripple factor as
much as possible, or at least to the point where the load circuit will not be adversely
affected by the remaining ac ripple voltage.
In the remaining pages in this group, we will examine typical circuits and variations
used for rectifiers and filters, and compare their performance.
As we have noted when looking at the Elements of a Power Supply, the purpose of the
rectifier section is to convert the incoming ac from a transformer or other ac power
source to some form of pulsating dc. That is, it takes current that flows alternately in both
directions as shown in the first figure to the right, and modifies it so that the output
current flows only in one direction, as shown in the second and third figures below.
The circuit required to do this may be nothing more than a single diode, or it may be
considerably more complex. However, all rectifier circuits may be classified into one of
two categories, as follows:
85
Half-Wave Rectifiers: An easy way to convert ac to pulsating dc is to simply allow half
of the ac cycle to pass, while blocking current to prevent it from flowing during the other
half cycle. The figure to the right shows the resulting output. Such circuits are known as
half-wave rectifiers because they only work on half of the incoming ac wave.
86
The Half-Wave Rectifier:
The simplest rectifier circuit is nothing more than a diode connected in series with the
ac input, as shown to the right. Since a diode passes current in only one direction, only
half of the incoming ac wave will reach the rectifier output. Thus, this is a basic half-
wave rectifier.
The orientation of the diode matters; as shown, it passes only the positive half-cycle of
the ac input, so the output voltage contains a positive dc component. If the diode were to
be reversed, the negative half-cycle would be passed instead, and the dc component of the
output would have a negative polarity. In either case, the DC component of the output
waveform is vp/ = 0.3183vp, where vp is the peak voltage output from the transformer
secondary winding.
87
It is also quite possible to use two half-wave rectifiers together, as shown in the
second figure to the right. This arrangement provides both positive and negative output
voltages, with each output utilizing half of the incoming ac cycle.
Note that in all cases, the lower transformer connection also serves as the common
reference point for the output. It is typically connected to the common ground of the
overall circuit. This can be very important in some applications. The transformer
windings are of course electrically insulated from the iron core, and that core is normally
grounded by the fact that it is bolted physically to the metal chassis (box) that supports
the entire circuit. By also grounding one end of the secondary winding, we help ensure
that this winding will never experience even momentary voltages that might overload the
insulation and damage the transformer.
While the half-wave rectifier is very simple and does work, it isn't very efficient. It
only uses half of the incoming ac cycle, and wastes all of the energy available in the other
half. For greater efficiency, we would like to be able to utilize both halves of the
incoming ac. One way to accomplish this is to double the size of the secondary winding
and provide a connection to its center. Then we can use two separate half-wave rectifiers
on alternate half-cycles, to provide full-wave rectification. The circuit is shown to the
right.
Because both half-cycles are being used, the DC component of the output waveform is
now 2vp/ = 0.6366vp, where vp is the peak voltage output from half the transformer
secondary winding, because only half is being used at a time.
88
This rectifier configuration, like the half-wave rectifier, calls for one of the
transformer's secondary leads to be grounded. In this case, however, it is the center
connection, generally known as the center tap on the secondary winding.
The full-wave rectifier can still be configured for a negative output voltage, rather
than positive. In addition, as shown to the right, it is quite possible to use two full-wave
rectifiers to get outputs of both polarities at the same time.
The full-wave rectifier passes both halves of the ac cycle to either a positive or
negative output. This makes more energy available to the output, without large intervals
when no energy is provided at all. Therefore, the full-wave rectifier is more efficient than
the half-wave rectifier. At the same time, however, a full-wave rectifier providing only a
single output polarity does require a secondary winding that is twice as big as the half-
wave rectifier's secondary, because only half of the secondary winding is providing
power on any one half-cycle of the incoming ac.
Actually, it isn't all that bad, because the use of both half-cycles means that the current
drain on the transformer winding need not be as heavy. With power being provided on
both half-cycles, one half-cycle doesn't have to provide enough power to carry the load
past an unused half-cycle. Nevertheless, there are some occasions when we would like to
be able to use the entire transformer winding at all times, and still get full-wave
rectification with a single output polarity.
89
The Full-Wave Bridge Rectifier:
The four-diode rectifier circuit shown to the right serves very nicely to provide full-
wave rectification of the ac output of a single transformer winding. The diamond
configuration of the four diodes is the same as the resistor configuration in a Wheatstone
Bridge. In fact, any set of components in this configuration is identified as some sort of
bridge, and this rectifier circuit is similarly known as a bridge rectifier.
If you compare this circuit with the dual-polarity full-wave rectifier above, you'll find
that the connections to the diodes are the same. The only change is that we have removed
the center tap on the secondary winding, and used the negative output as our ground
reference instead. This means that the transformer secondary is never directly grounded,
but one end or the other will always be close to ground, through a forward-biased diode.
This is not usually a problem in modern circuits.
90
To understand how the bridge rectifier can pass current to a load in only one direction,
consider the figure to the right. Here we have placed a simple resistor as the load, and we
have numbered the four diodes so we can identify them individually.
During the positive half-cycle, shown in red, the top end of the transformer winding is
positive with respect to the bottom half. Therefore, the transformer pushes electrons from
its bottom end, through D3 which is forward biased, and through the load resistor in the
direction shown by the red arrows. Electrons then continue through the forward-biased
D2, and from there to the top of the transformer winding. This forms a complete circuit,
so current can indeed flow. At the same time, D1 and D4 are reverse biased, so they do
not conduct any current.
During the negative half-cycle, the top end of the transformer winding is negative.
Now, D1 and D4 are forward biased, and D2 and D3 are reverse biased. Therefore,
electrons move through D1, the resistor, and D4 in the direction shown by the blue
arrows. As with the positive half-cycle, electrons move through the resistor from left to
right.
In this manner, the diodes keep switching the transformer connections to the resistor
so that current always flows in only one direction through the resistor. We can replace the
resistor with any other circuit, including more power supply circuitry (such as the filter),
and still see the same behavior from the bridge rectifier.
CURRENT TRANSFORMER
91
measuring instruments from what may be very high voltage in the monitored circuit.
Current transformers are commonly used in metering and protective relays in the
electrical power industry.
Design
Like any other transformer, a current transformer has a primary winding, a magnetic core,
and a secondary winding. The alternating current flowing in the primary produces a
magnetic field in the core, which then induces a current in the secondary winding circuit.
A primary objective of current transformer design is to ensure that the primary and
secondary circuits are efficiently coupled, so that the secondary current bears an accurate
relationship to the primary current.
The most common design of CT consists of a length of wire wrapped many times around
a silicon steel ring passed over the circuit being measured. The CT's primary circuit
therefore consists of a single 'turn' of conductor, with a secondary of many hundreds of
turns. The primary winding may be a permanent part of the current transformer, with a
heavy copper bar to carry current through the magnetic core. Window-type current
transformers are also common, which can have circuit cables run through the middle of
an opening in the core to provide a single-turn primary winding. When conductors
passing through a CT are not centered in the circular (or oval) opening, slight
inaccuracies may occur.
92
Current transformers used in metering equipment for three-phase 400 ampere electricity
supply
Shapes and sizes can vary depending on the end user or switchgear manufacturer. Typical
examples of low voltage single ratio metering current transformers are either ring type or
plastic moulded case. High-voltage current transformers are mounted on porcelain
bushings to insulate them from ground. Some CT configurations slip around the bushing
of a high-voltage transformer or circuit breaker, which automatically centers the
conductor inside the CT window.
The primary circuit is largely unaffected by the insertion of the CT. The rated secondary
current is commonly standardized at 1 or 5 amperes. For example, a 4000:5 CT would
provide an output current of 5 amperes when the primary was passing 4000 amperes. The
secondary winding can be single ratio or multi ratio, with five taps being common for
multi ratio CTs. The load, or burden, of the CT should be of low resistance. If the voltage
time integral area is higher than the core's design rating, the core goes into saturation
towards the end of each cycle, distorting the waveform and affecting accuracy.
Usage
Current transformers are used extensively for measuring current and monitoring the
operation of the power grid. Along with voltage leads, revenue-grade CTs drive the
electrical utility's watt-hour meter on virtually every building with three-phase service
and single-phase services greater than 200 amp.
93
The CT is typically described by its current ratio from primary to secondary. Often,
multiple CTs are installed as a "stack" for various uses. For example, protection devices
and revenue metering may use separate CTs to provide isolation between metering and
protection circuits, and allows current transformers with different characteristics
(accuracy, overload performance) to be used for the different purposes.
Safety precautions
Care must be taken that the secondary of a current transformer is not disconnected from
its load while current is flowing in the primary, as the transformer secondary will attempt
to continue driving current across the effectively infinite impedance. This will produce a
high voltage across the open secondary (into the range of several kilovolts in some
cases), which may cause arcing. The high voltage produced will compromise operator
and equipment safety and permanently affect the accuracy of the transformer.
A current transformer (CT) is a transformer which measures the current of another circuit.
It is coupled to an ammeter (A in the diagram) in its own circuit to perform this
measurement. Measuring high-voltage current directly would require insertion of
measuring instrumentation into the measured circuit--an unnecessary difficulty which
would draw down the very current meant to be measured. Also, the heat generated in the
94
measuring equipment from the high current could give false readings. Measuring current
indirectly with a CT is much more practical.
1.
Voltage Transformer
The difference with a CT is that the circuit with power has, effectively, one loop. The
powered circuit goes through the iron core only once. A CT is, therefore, a step-up
transformer.
CT & VT Formulae
2.
95
Recall also that the current and number of turns in the coils in a VT can be related as: i1
--- N1 = i2 --- N2. This is because for a coil (solenoid), B = mu --- i --- n, where mu here
means the magnetic permeability constant. Little intensity of B is lost from one coil to the
other with a good iron core, so the B equations for the two coils are effectively equal,
giving us i1 --- N1 = i2 --- N2.
However, N1 = 1 for the primary in the case of the current transformer. Is the single
power line effectively the equivalent of one loop? Does the last equation reduce to i1 = i2
--- N2? No, because it was based on solenoid equations. For N1 = 1, the following
formula is more appropriate: B = mu --- i/(2πr), where r is the distance of the center of
the wire to the point where B is measured or sensed (the iron core, in the transformer
case). So i1/(2πr) = i2 --- N2.
i1 is, therefore, merely proportional to the ammeter-measured value i2, reducing current
measurement to a simple conversion.
Common Uses
3.
The one central function of a CT is to determine the current in a circuit. This is especially
useful for monitoring high-voltage lines throughout the power grid. Another ubiquitous
use of CTs is in domestic electric meters. A CT is coupled with a meter to measure what
electrical usage to charge the customer.
Instrument Safety
96
4.
This is relevant because high current produces heat which can damage sensitive
measuring equipment, such as the resistor in an ammeter. Reducing i2 protects the
ammeter. It also prevents heat from throwing off the accuracy of the measurement.
Protective Relays
5.
CTs also protect the main lines of the power grid. An overcurrent relay is a type of
protective relay (switch) that trips a circuit breaker if a high-voltage current exceeds a
certain preset value. Overcurrent relays use a CT to measure the current, since the current
of a high-voltage line could not be measured directly.
97
(OR)
CURRENT TRANSFORMERS
Current transformers are used in electric metering for large load situations to reduce the
current level presented to the metering circuit in order to make it more manageable and
safe. This paper presents the basics of operation of current transformers and discusses the
in-service testing of current transformers to assure accurate performance.
2. BASICS OF OPERATION
2.1 Ratio
The ratio of a CT is referenced to a 5 amp secondary output for nominal full value input
current such that a CT ratio of 200 to 5 means that the CT would produce a secondary
current of 5 amps when exposed to a primary current of 200 amps. The CT manufacturer
classifies its CT’s by its ratio value called the rated ratio which is stamped on the
nameplate of the CT and that is the certified operating value of the CT.
98
2.3. Accuracy Class
The CT accuracy is determined by its certified accuracy class which is also stamped on
its nameplate. For example, a CT accuracy class of 0.3 means that the CT is certified by
the manufacturer to be accurate to within 0.3 percent of its rated ratio value for a primary
current of 100 percent of rated ratio. For primary currents of 10 percent of rated ratio the
specified accuracy for a given classification is double that of the 100 percent value or 0.6
percent for the above-stated case. The accuracy is relatively linear between these two
points. Hence a CT with a rated ratio of 200 to 5 with accuracy class of 0.3 would operate
within 0.45 percent of its rated ratio value for a primary current of 100 amps. To be more
explicit, for a primary current of 100.00 amps it is certified to produce a secondary
current between 2.489 amps and 2.511 amps.
Some CT’s are certified to be accurate for primary current values greater than 100 percent
of the rated ratio, called over-range. This over-range is designated by a rating factor
representing the factor by which the upper limit of the primary current can be increased
and still remain within certified accuracy. Hence a 200 to 5 rated ratio CT with a rating
factor of 2 will remain within its accuracy certification up to 400 amps (200 amps times
2). The rating factor of the CT is stamped on the nameplate of the CT. Typical rating
factors are 1, 1.5, 2, 3, and 4.
Voltage Transformers:
Instrument transformers are used for measurement and protective application, together
with equipment such as meters and relays. Their role in electrical systems is of primary
importance as they are a means of "stepping down" the current or voltage of a system to
measurable values, such as 5A or 1A in the case of a current transformers or 110V or
100V in the case of a voltage transformer. This offers the advantage that measurement
and protective equipment can be standardized on a few values of current and voltage.
99
Voltage transformers
Current transformers
Voltage transformers
Principle of operation
The standards define a voltage transformer as one in which "the secondary voltage is
substantially proportional to the primary voltage and differs in phase from it by an angle
which is approximately zero for an appropriate direction of the connections."
This, in essence, means that the voltage transformer has to be as close as possible to the
"ideal" transformer. In an "ideal" transformer, the secondary voltage vector is exactly
opposite and equal to the primary voltage vector, when multiplied by the turn’s ratio.
In a "practical" transformer, errors are introduced because some current is drawn for the
magnetization of the core and because of drops in the primary and secondary windings
due to leakage reactance and winding resistance. One can thus talk of a voltage error,
which is the amount by which the voltage is less than the applied primary voltage, and
the phase error, which is the phase angle by which the reversed secondary voltage vector
is displaced from the primary voltage vector.
100
The alphanumeric 16character X 2line LCD requires 8data lines and also 3
control signals. By using 2 ports, port 0&3 data pins are connected to LCD as data bus.
Port0 can be basically used as I/O port i.e. it can be programmed as an input or as an
output port.
To interface the LCD, to the Micro controller it require an 8 bit and also three
control signals differentiate the data from the control words send to the LCD. The Micro
controller has to send the necessary control words followed by the data to be displayed.
Depending on the operation to be performed the control words are selected and
passes to the LCD. The data to be displayed on the LCD is to be sent in the ASCII format.
Thus all the character to be displayed are converted into ASCII form and then sent to the
LCD along with different control words. The control word differentiated the various
operations and is executed. It is also possible to read the LCD data if required.
The control signals to the LCD are also provided by the Micro controller. This is
also done through pins 3.5,3.6&3.7.Through program necessary control signals are
passed to the LCD by using the bits of the port. The remaining can be used for some other
purpose if there is a need. The software controls the necessary ports and performs the task
it is designed for. The soft ware and associated hardware perform the LCD interface.
101
LCD DISPLAY
A liquid crystal is a material (normally organic for LCDs) that will flow like a
liquid but whose molecular structure has some properties normally associated with solids.
The Liquid Crystal Display (LCD) is a low power device. The power requirement is
typically in the order of microwatts for the LCD. However, an LCD requires an external
or internal light source. It is limited to a temperature range of about 0C to 60C and
lifetime is an area of concern, because LCDs can chemically degrade.
There are two major types of LCD s which are:
1) Dynamic-scattering LCD s
2) Field-effect LCD s
Field-effect LCD s are normally used in such applications where source of energy
is a prime factor (e.g., watches, portable instrumentation etc.).They absorb considerably
less power than the light-scattering type. However, the cost for field-effect units is
typically higher, and their height is limited to 2 inches. On the other hand, light-scattering
units are available up to 8 inches in height. Field-effect LCD is used in the project for
displaying the appropriate information. The turn-on and turn-off time is an important
consideration in all displays. The response time of LCD s is in the range of 100 to
300ms.The lifetime of LCD s is steadily increasing beyond 10,000+hours limit. Since the
colour generated by LCD units is dependent on the source of illumination, there is a wide
range of colour choice.
102
LCD is a type of display used in digital watches and many portable computers.
LCD displays utilize to sheets of polarizing material with a liquid crystal solution
between them. An electric current passed through the liquid causes the crystals to align so
that light cannot pass through them. LCD technology has advanced very rapidly since its
initial inception over a decade ago for use in laptop computers. Technical achievement
has resulted in brighter displace, higher resolutions, reduce response times and cheaper
manufacturing process.
The liquid crystals can be manipulated through an applied electric voltage so that
light is allowed to pass or is blocked. By carefully controlling where and what
wavelength (color) of light is allowed to pass, the LCD monitor is able to display images.
A backlight provides LCD monitor’s brightness.
Over the years many improvements have been made to LCD to help enhance
resolution, image, sharpness and response times. One of the latest such advancements is
TFT or Thin Film Transistor. TFT-LCD’s make use of a very thin transistor that is applied
to glass during acts as switch allowing control of light at the pixel level, greatly
enhancing image sharpness and resolution. This has been particularly important for
improving LCD’s ability to display small-sized fonts and image clearly.
Other advances have allowed LCD’s to greatly reduce liquid crystal cell
response times. Response time is basically the amount of time it takes for a pixel to
“change colors”. In reality response time is the amount of time it takes a liquid crystal
cell to go from being active to inactive.
LCD interfacing with 8052 is a real-world application. In recent years the LCD
is finding widespread use replacing LEDs (seven segment LEDs or other multisegment
LEDs). This is due to following reasons:
103
The declining prices of LCDs.
The ability to display numbers, characters and graphics. This is in contrast to LEDs,
which are limited to numbers and a few characters. An intelligent LCD display of two
lines, 20 characters per line, that is interfaced to the 8051.
PIN DIAGRAM
One of the, pins are numbered on the LCD’s print circuit board (PCB), but if
not, it is quite easy to locate pin1. Since this pin is connected to ground, it often has a
thicker PCB track, connected to it, and it is generally connected to metalwork at same
point.
PIN DESCRIPTIONS
While Vcc and Vss provide +5V and ground respectively, Vee is used for
controlling LCD contrast.
There are two very important registers inside the LCD. The RS pin is used for
their selection as follows.
If RS=0, the instruction command code register is selected, allowing the user to send a
command such as clear display, cursor at home, etc.,
104
If RS=1 the data register is selected, allowing the user to send data to be displayed on the
LCD.
R/W, read/write
R/W input allows the user to write information to the LCD or read information
from it. R/W=1 when reading; R/W=0 when writing.
EN, Enable
The LCD to latch information presented to its data pins uses the enable pin.
When data is supplied to data pins, a high-to-low pulse must be applied to this pin in
order for the LCD to latch in the data present at the data pins. This pulse must be a
minimum of 450ns wide.
The 8-bit data pins, D0-D7, are used to send information to the LCD or read the
contents of the LCD’s internal registers.
To display letters and numbers, we send ASCII codes for the letters A-Z, a-z,
and numbers 0-9 to these pins while making RS=1.
There are also instruction command codes that can be sent to the LCD to clear
the display or force the cursor to the home position or blink the instruction command
codes.
We also use RS=0 to check the busy flag bit to see if the LCD is ready to
receive information. The busy flag is D7 and can be read when R/W=1 and RS=0, as
follows: if R/W=1,RS=0. When D7=1 (busy flag=1), the LCD is busy taking care of
internal operations and will not accept any information.
When LCD is powered up, the display should show a series of dark squares,
possibly only on part of display. These characters are actually in their off state, so the
contrast control should be adjusted anti-clockwise until the squares are just visible. The
display module resets itself to an initial state when power is applied, which curiously has
105
the display blanked off so that even if characters are entered, they cannot be seen. It is
therefore necessary to issue a command at this point, to switch the display on.
Prototype circuit:
OPERATING INSTRUCTIONS
INSTRUCTION CODE EXPLANATIONS
106
Tab 6.6.1 Register Selection
ADDRESS COUNTER (AC)
The counter specifies an address when data is written into DD RAM or CG
RAM and the data stored in DD RAM or CG RAM is read out. If an Address Set
instruction (for DD RAM or CG RAM) is written in the IR, the address information is
transferred from the IR to the AC. When display data is written into or read from DD
RAM or CG RAM, the AC are output to DBO to DB6; refer to above
“Register Selection Table” when RS = 0 and R/W= 1.
Clear all display memory and return the cursor to the home position. In other words, the
cursor returns to the first character block on the first line on all 1, 2, and 4 line character
modules except L4044. If the above is entered on E2 (the second controller for lines 3
and 4), the cursor will return to the first character on the third line.
Returns cursor to home position. First line first character blocks on all 1, 2 and 4 line
display; except L4044 refer “clear display”: (Address 0; A,, “80”). The contents of DD
107
RAM remain unchanged.
I/D: Increments (I/D = 1) or decrements (I/D = 0) the DD RAM address by one block
when writing or reading a character code from DD RAM or CG RAM. The cursor
automatically moves to the right when incremented by one or to the left if decremented
by one.
108
D: Display is turned ON when D = 1 and OFF when D =0. When display is OFF, display
data in DD RAM remains unchanged. Information comes back immediately when D = 1
is entered.
C: Cursor is displayed when C = 1 and not displayed when C = 0. If the cursor
disappears, function of I/D etc.
S: Shifts the entire display to either the right or left when S = 1 (high). When S = 1 and
I/D = 1 the display shifts one position to the left. When S = 1 and I/D = 0 the display
shifts one position to the right. This right or left shift occurs after each data write to DD
RAM. Display is not shifted when reading from DD RAM. Display is not shifted when S
= 0.
In a 5 x 7 dot matrix there is an eighth line which functions as the cursor.
B: When B = 1, the character at the cursor position starts blinking. When B = 0 the cursor
does not blink. The blink is done by stitching between the all black dot matrix and
displayed character at 0.4 second intervals. The cursor and the blink can be set at the
same time (fosc = 250 kHz).
5 X 7 DOT MATRIX
Cursor Conditions
109
CURSOR OR DISPLAY SHIFT
Cursor/Display Shift moves the cursor or shifts the display without changing the DD
RAM contents. The cursor position and the AC contents match. This instruction is
available for display correction and retrieval because the cursor position or display can be
shifted without writing or reading display data. In case of a 2-line display, the cursor is
shifted from character block 40 of line 1 to character block 1 of line 2. Displays of lines 1
and 2 are shifted at the same time. In case of a 4-line display, the cursor does not move
continuously from line 2 to line 3. The cursor is shifted from character block 40 of line 3
to character block 1 of line 4. Displays of lines 3 and 4 are shifted at the same time. The
display pattern of line 2 or 4 is not shifted to line 1 or 3.
110
ADC MODULE
THEORY:
ADC is short for Analog Digital Converter, Sometimes called a A-D or A to D
Converter. An ADC is a device that converts a continuous analog signal to a multi-level
digital signal without altering its content. The signals that are monitored are sounds,
movement, and temperature into binary code for the PC.
(or)
Analog to digital (A/D, ADC) converters are electrical circuit devices that convert
continuous signals, such as voltages or currents, from the analog domain to the digital
domain where the signals are represented by numbers
Most processing equipment today are digital in nature, and they work with signals
which are binary valued. In a digital or binary representation, a signal is represented by a
word, which is composed of a finite number of bits. The processing of signals is
preferably carried out in the digital domain because digital processing is fast, accurate
and reliable. Analog to digital converters are widely used for converting analog signals to
corresponding digital signals for many electronic circuits. Analog to digital converters
allow the use of sophisticated digital signal processing systems to process analog signals,
which are common in the real world. Many modern electronic systems require conversion
of signals from analog to digital or from digital to analog form. Circuits for performing
these functions are now required in numerous common consumer devices such as digital
cameras, cellular telephones, wireless data network equipment, audio devices such as
MP3 players, and video equipment such as digital video disk (DVD) players, high
definition digital television (HDTV), and numerous other products. Analog to digital
converters (ADC's) form an essential link in the signal processing pathway at the
interface between the analog and digital domains. Advances in ADC technology have
111
increased the speed, lowered the cost, and reduced the power requirements of analog to
digital converters, and resulted in a proliferation of ADC applications.
The illustration shows a typical three-bit binary representation of a range of input signals,
partitioned into eight quanta. For example, a signal in the vicinity of 3/8; full scale
(between 5/16 and 7/16) will be coded 011 (binary 3).
Applications of ADC:
Digital camera or scanner uses A/D converters to transform the variable charges in
CCD and CMOS chips into the binary data that represent pixels.
Cell phone and digital desk phone has an ADC converter that converts the pressure of
sound waves into PCM code Etc.
112
ADC0808:
This is 8-Bit µP Compatible A/D Converters with 8-Channel Multiplexer. The
ADC0808 data acquisition component is a monolithic CMOS device with an 8-bit
analog-to-digital converter,8-channel multiplexer and microprocessor compatible Control
logic. The 8-bit A/D converter uses successive approximation as the conversion
technique. The converter features a high impedance chopper stabilized comparator, a
256R voltage divider with analog switch tree and a successive approximation register.
The 8-channel multiplexer can directly access any of 8-single-ended analog signals. The
device eliminates the need for external zero and full-scale adjustments. Easy interfacing
to microprocessors is provided by the latched and decoded multiplexer address inputs and
latched TTL TRI-STATE outputs.
Features
Easy interface to all microprocessors
Operates ratio metrically or with 5 VDC or analog span adjusted voltage reference
No zero or full-scale adjust required
8-channel multiplexer with address logic
0V to 5V input range with single 5V power supply
Outputs meet TTL voltage level specifications
ADC0808 equivalent to MM74C949
ADC0809 equivalent to MM74C949-1
Key Specifications
Resolution 8 Bits
Total Unadjusted Error ±1⁄2 LSB and ±1 LSB
Single Supply 5 VDC
Low Power 15 mW
Conversion Time
113
FUNCTIONAL DESCRIPTION:
The ADC0808 shown in figure can be functionally divided into 2 basic sub
circuits. These two sub circuits are an analog multiplexer and an A/D converter. The
multiplexer uses 8 standard CMOS analog switches to provide to up to 8 analog inputs.
The switches are selectively turned on, depending on the data latched into a 3-bit
multiplexer address register.
114
As mentioned earlier, there are 8 clock periods per approximation. Even though
there is no conversion in progress the ADC0808 is still internally cycling through these 8
clock periods. A start pulse can occur any time during this cycle but the conversion will
not actually begin until the converter internally cycles to the beginning of the next 8
clock period sequence. As long as the start pin is held high no conversion begins, but
when the start pin is taken low the conversion will start within 8 clock periods. The EOC
output is triggered on the rising edge of the start pulse. It, too, is controlled by the 8 clock
period cycle, so it will go low within 8 clock periods of the rising edge of the start pulse.
One can see that it is entirely possible for EOC to go low before the conversion starts
internally, but this is not important, since the positive transition of EOC, which occurs at
the end of a conversion, is what the control logic is looking for.
Once EOC does go high this signals the interface logic that the data resulting from
the conversion is ready to be read. The output enable(OE) is then raised high. This
enables the TRI-STATE outputs, allowing the data to be read. Figure shows the timing
diagram.
115
PIN DIAGRAM:
CONNECTION DIAGRAM:
116
SC (Chip Selection): By using this selection Bit you can select the Chip. After selecting
this bit the chip is ready to do operation. By using HIGH (1) you can select this pin as an
active high.
EOC (End of Conversion): After End of ADC Conversion EOC bit is set to high.
CHANNEL SELECTION:
117
118
FLOW CHART:
119
Set callCSF
CIRCUIT DESCRIPTION:
120
SOFTWARE DESCRPITION:
ABOUT SOFTWARE
µVision3 adds many new features to the Editor like Text Templates, Quick Function
Navigation, and Syntax Coloring with brace high lighting Configuration Wizard for
dialog based startup and debugger setup. µVision3 is fully compatible to µVision2 and
can be used in parallel with µVision2.
What is µVision3?
µVision3 is an IDE (Integrated Development Environment) that helps you write, compile,
and debug embedded programs. It encapsulates the following components:
A project manager.
A make facility.
Tool configuration.
Editor.
A powerful debugger.
To help you get started, several example programs (located in the \C51\Examples,
\C251\Examples, \C166\Examples, and \ARM\...\Examples) are provided.
121
HELLO is a simple program that prints the string "Hello World" using the Serial
Interface.
MEASURE is a data acquisition system for analog and digital systems.
TRAFFIC is a traffic light controller with the RTX Tiny operating system.
SIEVE is the SIEVE Benchmark.
DHRY is the Dhrystone Benchmark.
WHETS is the Single-Precision Whetstone Benchmark.
Additional example programs not listed here are provided for each device architecture.
122
1. Select Debug - Start/Stop Debug Session.
2. Use the Step toolbar buttons to single-step through your program. You may enter
G, main in the Output Window to execute to the main C function.
3. Open the Serial Window using the Serial #1 button on the toolbar. Debug your
program using standard options like Step, Go, Break, and so on.
Starting µVision2 and creating a Project
µVision2 is a standard Windows application and started by clicking on the program icon.
To create a new project file select from the µVision2 menu
Project – New Project…. This opens a standard Windows dialog that asks you for the
new project file name. We suggest that you use a separate folder for each project. You can
simply use the icon Create New Folder in this dialog to get a new empty folder. Then
select this folder and enter the file name for the new project, i.e. Project1. µVision2
creates a new project file with the name PROJECT1.UV2 which contains a default target
and file group name. You can see these names in the Project
Window – Files.
Now use from the menu Project – Select Device for Target and select a CPU for your
project. The Select Device dialog box shows the µVision2 device database. Just select the
microcontroller you use. We are using for our examples the Philips 80C51RD+ CPU.
This selection sets necessary tool options for the 80C51RD+ device and simplifies in this
way the tool Configuration
Building Projects and Creating a HEX Files
Typical, the tool settings under Options – Target are all you need to start a new
application. You may translate all source files and line the application with a click on the
Build Target toolbar icon. When you build an application with syntax errors, µVision2
will display errors and warning messages in the Output Window – Build page. A double
click on a message line opens the source file on the correct location in a µVision2 editor
window.Once you have successfully generated your application you can start debugging.
After you have tested your application, it is required to create an Intel HEX file to
download the software into an EPROM programmer or simulator. µVision2 creates HEX
files with each build process when Create HEX files under Options for Target – Output is
123
enabled. You may start your PROM programming utility after the make process when
you specify the program under the option Run User Program #1.
CPU Simulation
µVision2 simulates up to 16 Mbytes of memory from which areas can be mapped for
read, write, or code execution access. The µVision2 simulator traps and reports illegal
memory accesses.
In addition to memory mapping, the simulator also provides support for the integrated
peripherals of the various 8051 derivatives. The on-chip peripherals of the CPU you have
selected are configured from the Device
Database selection
You have made when you create your project target. Refer to page 58 for more
Information about selecting a device. You may select and display the on-chip peripheral
components using the Debug menu. You can also change the aspects of each peripheral
using the controls in the dialog boxes.
Start Debugging
You start the debug mode of µVision2 with the Debug – Start/Stop Debug Session
command. Depending on the Options for Target – Debug Configuration, µVision2 will
load the application program and run the startup code µVision2 saves the editor screen
layout and restores the screen layout of the last debug session. If the program execution
stops, µVision2 opens an editor window with the source text or shows CPU instructions
in the disassembly window. The next executable statement is marked with a yellow
arrow. During debugging, most editor features are still available.
For example, you can use the find command or correct program errors. Program source
text of your application is shown in the same windows. The µVision2 debug mode differs
from the edit mode in the following aspects:
_ The “Debug Menu and Debug Commands” described on page 28 are Available. The
additional debug windows are discussed in the following.
_ The project structure or tool parameters cannot be modified. All build Commands are
disabled.
Disassembly Window
124
The Disassembly window shows your target program as mixed source and assembly
program or just assembly code. A trace history of previously executed instructions may
be displayed with Debug – View Trace Records. To enable the trace history, set Debug –
Enable/Disable Trace Recording.
If you select the Disassembly Window as the active window all program step commands
work on CPU instruction level rather than program source lines. You can select a text line
and set or modify code breakpoints using toolbar buttons or the context menu commands.
You may use the dialog Debug – Inline Assembly… to modify the CPU
instructions. That allows you to correct mistakes or to make temporary changes to the
target program you are debugging.
SOFTWARE DESCRPITION:
SOURCE CODE
125
4. Then Click on New Project
5. Save the Project by typing suitable project name with no extension in u r own
folder sited in either C:\ or D:\
126
9. Select AT89C52 as shown below
127
12. Then Click either YES or NO………mostly “NO”
14. Now double click on the Target1, you would get another option “Source group
1” as shown in next page.
15. Click on the file option from menu bar and select “new”
128
16. The next screen will be as shown in next page, and just maximize it by double
clicking on its blue boarder.
18. For a program written in Assembly, then save it with extension “. asm” and
for “C” based program save it with extension “ .C”
129
19. Now right click on Source group 1 and click on “Add files to Group Source”
20. Now you will get another window, on which by default “C” files will appear.
130
21. Now select as per your file extension given while saving the file
22. Click only one time on option “ADD”
23. Now Press function key F7 to compile. Any error will appear if so happen.
131
26. Then Click “OK”
27. Now Click on the Peripherals from menu bar, and check your required port as
shown in fig below
28. Drag the port a side and click in the program file.
132
29. Now keep Pressing function key “F11” slowly and observe.
30. You are running your program successfully
133
CONCLUSION
has been successfully designed and tested. Integrating features of all the hardware
components used have developed it. Presence of every module has been reasoned out and
placed carefully thus contributing to the best working of the unit. Secondly, using highly
advanced IC’s and with the help of growing technology the project has been successfully
implemented.
134
BIBLIOGRAPHY
-Kenneth J.Ayala
-B.Ram
-Ramesh S.Gaonkar
Electronic Components
-D.V.Prasad
Wireless Communications
- Theodore S. Rappaport
135
Mobile Tele Communications
- William C.Y. Lee
www.national.com
www.atmel.com
www.microsoftsearch.com
www.geocities.com
136