J H G F E D C B A
ANDRÓM
J H G F E D C B A
EJE
AVENIDA
PREPARATORIA IBERO
O
L
LG
753 749 749 750 750 749 751 396
L SO
HIDA
753 749 749 750 750 749 751 396 PLACA DE
A DE
UEL
EDA
ENID
MIG
N
ANDRÓM
AV
REMATE
AVENIDA
N.T.C. +13.45
12 12
VER PROYECTO ESTRUCTURAL
DEL SOL
VER PROYECTO ESTRUCTURAL AMPLIACION
AVENIDA
AVENIDA ANTARES
635
AVENIDA ANTARES NO. 5502,
EDIFICIO EXISTENTE PB-3(INF.) PB-2 (INF.) PB-2 (INF.) PB-3(INF.) COLONIA RESERVA TERRITORIAL
ATLIXCAYOTL, MUNICIPIO DE SAN
PB-3(SUP.) PB-2(SUP.) PB-2(SUP.) PB-3(SUP.) ANDRÉS CHOLULA, PUEBLA.
CR-6 CR-6 CR-6 CR-1 CR-3 CR-3 CR-1 CR-6 CV-2 CV-2
CV-2 CV-2
11 CV-2 CV-2 CR-6 CV-2 CV-2
11 PLACA BASE PLANTA ESQUEMÁTICA
CV-1
METÁLICO DE
548
548
Ab
Bb'
PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) ANGULO Eb
PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) REFUERZO
CV-1 CV-1 LONGITUDINAL
Fb
ANCLAJE CON
COLUMNA Gb
1048
1048
EXISTENTE 8.8
Hb
CONEXIONES
7 Ib
CV-1 PB-2 (INF.) PB-2 (INF.) PB-2 (INF.) PB-2 (INF.) CINTURÓN
PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) VER PLANO DE CV-1
METÁLICO DE
Jb
PB-3 (SUP.) PB-3 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-3 (SUP.) PB-3 (SUP.) PB-2(SUP.) PB-2(SUP.) PB-2(SUP.) PB-2(SUP.) CONEXIONES
CR-4 CR-4 CR-5 CR-5 CR-4 CR-4 CR-5 CR-5 CE PLACA BASE ARRANQUE
CR-6 CR-6 CE CE CE Kb
INFERIOR
8.6 8.6 CR-6 CR-6 N.T.C. +8.95 Lb
CV-1
CV-1
546
546
PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.)
PB-3(INF.) PB-2 (INF.) PB-2 (INF.) PB-3(INF.)
PB-3 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-3 (SUP.) SIN ESC.
PB-3(SUP.) PB-2(SUP.) PB-2(SUP.) PB-3(SUP.)
CR-6 CR-1 CR-3 CR-3 CR-1 CR-6 CR-6 CR-6 CR-1 CR-3 CR-3 CR-1 CR-6 CR-6
CV-2 CV-2 CV-2 CV-2 CV-2 CV-2 CV-2 CV-2 K J H G F E D C B A 9b' 10b 11b 12b 13b 14b 15b15b' 16b 17b 18b 19b 20b 21b 22b 23b 24b
7.9 7.9
Niv el 04
18.000
Niv el 03
13.500
NIVEL 02, 03
SUPERIOR CINTURÓN
4.500
496
496
PLANTA BAJA, NI VEL
01
0.000
METÁLICO DE
SIN ESC.
ARRANQUE
SIMBOLOGÍA
7.4 7.4
SOLERA DE NIVEL INDICA NIVELES N.D. NIVEL DE DESPLANTE
XX.XX EN PLANTA N.P.T NIVEL DE PISO TERMINADO
REFUERZO N.T.C. NIVEL TOPE DE CONCRETO
ANGULO HORIZONTAL INDICA NIVELES EN N.L.A.L. NIVEL LECHO ALTO DE LOSA
772
772
NIVEL
XX.XX CORTE Y ALZADO
REFUERZO N.L.B.L. NIVEL LECHO BAJO DE LOSA
X
VER PROYECTO LONGITUDINAL ANCLAJE CON
INDICA CORTE N.S.F. NIVEL SUPERIOR DE FIRME
7766
7766
XXX X =REFERENCIA DE CORTE N.PR. NIVEL DE PRETIL
XXX =REFERENCIA DE PLANO N.C. NIVEL DE CERRAMIENTO
COLUMNA
ESTRUCTURAL AMPLIACION EXISTENTE X.XX INDICA COTA PEND. PENDIENTE
VAR. VARIABLE
6'' 6'' P.B. PLACA BASE
EDIFICIO EXISTENTE INDICA CAMBIO
DE NIVEL
P.L. PLACA
CINTURÓN X% INDICA PENDIENTE
METÁLICO DE
ARRANQUE
VER PROYECTO PLACA BASE DIRECCIÓN LOSACERO
908
908
INFERIOR
N.T.C. +4.45
ESTRUCTURAL AMPLIACION
EDIFICIO EXISTENTE
NOTAS
1.- LAS COTAS RIGEN AL DIBUJO.
5 5 2.- LAS COTAS Y NIVELES ESTAN EN CENTIMETROS.
3.- LAS COTAS Y NIVELES SE VERIFICARAN EN OBRA.
4.- EL EMPLEO DE ESTE PLANO ES UNICAMENTE PARA LA
VER PLANO DE CAPITEL ESPECIALIDAD INDICADA
5.- TODAS LAS ACOTACIONES, DIMENSIONES, TRAZOS,
CONEXIONES PLACA BASE UBICACIÓN, PAÑOS FIJOS Y NIVELES DEBERÁN SER
673
673
SUPERIOR VERIFICADOS EN PLANOS ARQUITECTÓNICOS Y DE
INSTALACIONES LOS CUALES RIGEN DE ACUERDO A SU
PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-3(INF.) PB-2 (INF.) PB-2 (INF.) PB-3(INF.) CINTURÓN ESPECIALIDAD.
PB-2(SUP.) PB-2(SUP.) METÁLICO DE 6.-EL NIVEL DE PISO TERMINADO (N.P.T.) +/- 0,00 DE LAS
PB-3 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-3 (SUP.) PB-3(SUP.) PB-3(SUP.) PLANTAS BAJAS DEL CONJUNTO HOSPITALARIO ESTARÁ
CR-6 CR-6 CR-6 CR-6 CV-2 CR-6 CR-6 SOLERA DE ARRANQUE ASOCIADO A LA CURVA DE NIVEL 2116.09m, RELATIVA AL
CV-2 CV-2 CR-1 CR-3 CR-3 CR-1 CV-2 CV-2 CR-6 CV-2 CR-6 CR-1 CR-3 CR-3 CR-1
TAQUIMÉTRICO DEL PREDIO, SIENDO EL BANCO DE NIVEL
4.1 4.1 CV-2 CV-2
REFUERZO PROFUNDO (B.N.P.) UTILIZADO, PROPORCIONADO POR EL
HORIZONTAL ANCLAJE CON I.M.S.S., CON VALOR EN COTA ABSOLUTA DE 2116.00
M.S.N.M.M. (VALOR TOMADO SEGÚN PLANO LT-4 DE FECHA
COLUMNA MARZO 2018 EMITIDO POR I.M.S.S.)
CV-1
CV-1
540
540
PB-2 (INF.) PB-2 (INF.) PB-2 (INF.) PB-2 (INF.) EXISTENTE
PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) ANGULO
SELLO IMSS
PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2(SUP.) PB-2(SUP.) PB-2(SUP.) PB-2(SUP.) DIVISIÓN DE PROYECTOS
CR-6 REFUERZO
CR-4 CR-4 CR-5 CR-5 CR-4 CR-4 CR-6 CE CR-4 CR-5 CR-5 CR-4 CE LONGITUDINAL CINTURÓN METÁLICO
3.4 3.4 DE ARRANQUE
CR-6 CR-6 ING. JOSÉ MANUEL RUÍZ MARQUEZ
NOMBRE
CONTRATRABE
CV-1 CV-1 PLACA BASE
N.P.T. 0.00
INFERIOR
1058
1058
FIRMA FECHA
CV-1 VER PLANO DE PB-2 (INF.) PB-2 (INF.) PB-2 (INF.) PB-2 (INF.) CV-1 SEGURIDAD Y SOLIDARIDAD SOCIAL
PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) EL CONTENIDO DE ÉSTE PLANO Y/O DOCUMENTO, CUMPLE CON LAS NORMAS
PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-2 (SUP.) CONEXIONES PB-2(SUP.) PB-2(SUP.) PB-2(SUP.) PB-2(SUP.) INSTITUCIONALES DE LA ESPECIALIDAD.
ES RESPONSABILIDAD DEL CONTRATISTA EL DESARROLLO DEL ANÁLISIS, DISEÑO DE
CR-6 CR-4 CR-4 CR-5 CR-5 CR-4 CR-4 CR-6 CE CR-4 CR-5 CR-5 CR-4 CE CR-6 DETALLES TÉCNICOS, ASÍ COMO SE DERIVA PARA SU CORRECTA APLICACIÓN EN LA
OBRA, Y CON EL ESTRICTO APEGO A LOS SERVICIOSCONTRATADOS.
2 2 CR-6 EL GRUPO CONSTRUCTOR DEBE CONSULTAR Y COMPAGINAR ÉSTE PLANO CON LAS
GUÍAS TÉCNICAS DE CONSTRUCCIÓN DE OBRA CIVIL E INSTALACIONES DEL IMSS.
CV-1
CV-1
542
542
CONTRATISTA:
PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-1 (INF.) PB-3(INF.) PB-2 (INF.) PB-2 (INF.) PB-3(INF.) N.D.
PB-3 (SUP.) PB-2 (SUP.) PB-2 (SUP.) PB-3 (SUP.) PB-3(SUP.) PB-2(SUP.) PB-2(SUP.) PB-3(SUP.)
CR-6 CR-6 CR-1 CR-3 CR-3 CR-1 CR-6 CR-6 CR-6 CR-6 CR-1 CR-3 CR-3 CR-1 CR-6 CR-6
CV-2 CV-2 CV-2 CV-2 CV-2
1 CV-2 CV-2
1
CV-2 CV-2 CV-2
H H 0 20 40 100 200
REFUERZO ESC 1:200
LONGITUDINAL
TABLA DE SECCIONES DE ACERO PROYECTO COMPLEMENTARIO DE
L
REFUERZO
TRANSVERSAL REFUERZO ESTRUCTURAL DEL EDIFICIO
COLUMNA DE CONCRETO COLUMNA DE CONCRETO EXISTENTE
EXISTENTE (CE) REFORZADA (CR) DIRECTOR GENERAL
MTRO. TUFFIC MIGUEL ORTEGA
NOM. DESCRIPCIÓN DIRECCIÓN DE ADMINISTRACIÓN
COLUMNA DE CONCRETO MTRA. NORMA GABRIELA LOPEZ CASTAÑEDA
CONTRAVIENTO EN H=54cm
CE TITULAR DE LA COORDINACIÓN DE
CAJON L=54cm INFRAESTRUCTURA INMOBILIARIA DIEGO ANTONIO ACEVEDO NUEVO
NOM. DESCRIPCIÓN COLUMNA DE CONCRETO TITULAR DE LA COORDINACIÓN
SECCIÓN CAJÓN CR-1 H=54cm REFUERZO LONGITUDINAL=LI150x9.5 TÉCNICA DE PROYECTOS Y
CONSTRUCCIÓN DE INMUEBLES LIC.EDUARDO MARTÍNEZ FRAUSTO
CV-1 d=400mm tf=22mm REFUERZO TRANSVERSAL=SOLERA101x8
L=54cm
b=400mm tw=22mm TITULAR DE LA DIVISIÓN DE
PROYECTOS ING. ARQ. FEDERICO LÓPEZ ROSAS
COLUMNA DE CONCRETO
SECCIÓN CAJÓN CR-2 H=54cm REFUERZO LONGITUDINAL=LI 127x8
CV-2 d=350mm tf=22mm
L=54cm REFUERZO TRANSVERSAL=SOLERA101x6 LOCALIDAD SAN ANDRÉS CHOLULA, PUEBLA REVISIÓN
tw=22mm
b=350mm
SECCIÓN CAJÓN
CV-3 d=300mm tf=16mm
COLUMNA DE CONCRETO
CR-3 H=54cm REFUERZO LONGITUDINAL=LI 127x8
UBICACIÓN AVENIDA ANTARES NO. 5502, COLONIA
RESERVA TERRITORIAL ATLIXCAYOTL,
MUNICIPIO DE SAN ANDRÉS CHOLULA, CLAVE DEL PLANO
0
L=54cm REFUERZO TRANSVERSAL=SOLERA101x6 PUEBLA.
b=300mm tw=16mm TIPO DE UNIDAD
COLUMNA DE CONCRETO HOSPITAL GENERAL REGIONAL
H.G.R.
CR-4 H=54cm REFUERZO LONGITUDINAL=LI 127x8 H.G.R. 205 CAMAS
REF-011
COLUMNA DE CONCRETO NIVEL
CR-5 H=54cm REFUERZO LONGITUDINAL=LI 127x8 INGENIERÍA CIVIL, PLANTA
L=54cm REFUERZO TRANSVERSAL=SOLERA101x6 BAJA-NIVEL1 COLUMNAS
COLUMNA DE CONCRETO REFUERZO
CR-6 H=54cm REFUERZO LONGITUDINAL=LI 150x9.5 SEGURIDAD Y SOLIDARIDAD SOCIAL
tipo de contrato: FECHA: ESCALA:
L=54cm REFUERZO TRANSVERSAL=SOLERA101x8 INDICADA