RE 92450/00.83
MANNESMANN Variable Displacement Pump A2V RE
ROT Series 5, for open, closed and semi-closed circuits
Axil psion unt, bent axis design ai 92450/09.83
Brueninghaus Hydromatik ‘Sizes 250.,.1000 High pressure range up replaces 01.82
Description
‘Axial piston unit of bent axis design with variable dis-
placement, for hydrostatic drives in closed and semi-
‘closed, and open circuits,
Maximum flow is proportional to the drive speed an dis-
placement and is infinitely variable at constant drive
‘speed.
‘Comprehensive control programme for every control
and regulating function.
‘Special Features of Series 5:
New, simplified high performance rotary group with en-
hanced technical data and well-oroven spherical con-
trol area.
Section
Housed pump for closed circuit
Heavy duty rolling bearings for intermittent high pres-
sure operation.
For continuous duty at high pressures, hydrostatic bea-
rings are available.
‘Operation on fire-resistant tlulds is possible (please
‘consult us).
Improved port plate design and compact design redu-
‘ces noise level by 5 dBA.
‘Complete primary units with all auxiliary devices for
closed circuits (see RE 93700).
ie
Brueninghaus Hycromatik 1RE 92450/09.83
‘Variable Displacement Pump A2V (Series 5)
short code
Ordering Code
azv|s00}ov| Gc | R| 5 |G] P
{tnd
Pump Type To ____shattend
Axial piston keyed shaft
eee acomont EZ] wed on
= plined shat
Size Design
aa)
@
submersible pump Ce]
jm
Sie (=
displacement Ge ‘sizes 250 — 1000
terme Range sounting
howe pune
Teen ass
fange mounting
sizes 2 — 107 sie 500 and 100
Seohe aa feat mounting
Size 2000 ~ on enauiry oer
Contot Device ——
series
A
Direction of Rotation
(Wlowed on drive shaft)
clockwise oz
without control
hydraulic contrat
pressure related
‘Adaltional functions:
Constant HP control (L) anti-clockwise
Electrical control (RMVB)
Pressure regulation (DAS) Type of Circult
(Details in clear text)
closed circuit &
hydraviie contro! CW)
servo stom somi-closed circuit, CH]
hysrautic contot CR] pon creat = CY
flow related
hydraulic control
flow related
Design E
fortitingot = CS]
for fitting of
servo valve and
bypass valve
sisctonic conver CED]
elestonie cont EO
with bypass valve Ea
etociric conto [EC]
electro-mechanical
handwhee! control [MA]
pressure regulator,
hydraulically operated
with pressure
Unloading
with two point sem closed clreult
Control
Sith two point conto! AH] oe poo
waa ieee 7
wt we ‘ | "H
Point control e Os
pressure regulator, J L
slectro-nydraulically kt
operated
‘open circuit
AB service ports $ suction port
Ordering Example A2V.500.0V.G.R.5.6.P A.B additional ports + Gil rain
Variable displacement pump A2V, size 600 without control de- Ky, KK flushing ports VU flushing port
vice, closed clrcult, clockwise rotation, series 5, design G,ke- case drain (for flushing of
yed ‘shaft My Mp gauge connections bearings)
2. Brueninghaus HydromatikVariable Displacement Pump A2V (Series 5)
Technical Data
Inlet Pressure
Minimum pressure at port § (suction inlat)
Pre 08 bar
Prax (S88 case pressure)
‘The boost prassure ina closed circuit Is set at 16 bar.
Outlet Operating Pressure
Pressure at ports A or B
Rated pressu
Peak pressure
(Pressure data to DIN 24312)
‘With pulsating pressures in excess of 315 bar, we reaommend
using splined shafts to DIN 5480.
Py 350 bi
Prnex 400 bar
Case Pressure
Maximum permissible pressure In pump casing
Prax at bar abe,
‘The permiasible preasure Is, however, dependent on speed.
‘Standard shaft seal
‘Size 956
Size 250
8
é
t * ~
3
£3
£2 -
3 I ||
& 0 1000 2000 2500
‘Speed n (7pm) —m
‘A higher case drain pressure Is possible by fitting glide ring
seals — soe RE 94104, When ordering state in clear text "with
lide ring seal
Mounting position: Optional. (use case drain port at highest
point). The pump housing must always be filled with ol
Hydraulic Fluid
Operating Viscosity Range
inorder to obtain optimum efficiency and service life, we re
‘commend that the operating viscosity (at operating temper
ture) be selected in the range.
Yenr= optimum operating viscosity 16..96 mm/s
{as referred to the circult temperature in closed circuits and
the tank temperature in open circuits.
Viscosity Limits
‘The following values are valid for extreme operating condi
tions:
10 mm/s
for short periods with a max. permissible leakage
oll temperature of 90° C,
nx = 1000 min/s
for short periods upon cold start.
Prior to project design, please see our data shoot RE 90220 for
detailed information on the selection of fluids on an mineral
oll base and application conditions.
RE 92450/09.83
Selection Diagram
Notes on Selection of the Hydraulle Fluld
For correct selection of the hydraulic fluld,
know the operating temperature in relation to the ambient
temperature: In closed clrcults this Is the circuit temperatu
In open circuits the tank temperature,
‘The fluid should be selected so that in the operating tempera
ture range the operating viscosity lies within the optimum ran-
(ay) (808 shaded section of selection diagram), We recom-
mend thatthe higher viscosity grade be selected in each case.
Example: At an ambient temperature of X° G, the operating
‘temperature in the clrouit is 60° C. Within the optimum visco:
sity range { vay ; shaded section) this corresponds to viscost
ty grades VG 46 and VG 68. VG 68 is selected.
Note: The leakage oll temperature is influenced by pressu-
‘eand speed and is always higher than the cireult or tank tem-
perature. It must not be allowed to increase beyond 20° C.
If 111s not possible to maintain the above conditions because
fof extreme operating parameters or high ambient temperatu-
res, we recommend flushing of the bearings via port U.
Flushing
flows
size
sq Vinin
250 355 500 1000
125 16 25 40
Temperature of flushing fluid < tank temperature
When using water-based and synthetic fluids, see our data
shoot RE 90223,
Filtration
Recommended filtration 10 micron
Coarser filtration of 25 — 40 microns is possible, but longer
‘component Ife will be achieved using 10 micron f
to lower component wear.
Direction of Flow Through Pump
‘Anti-lockwise rotation
Clockwise rotation
Swivel open closed and open closed and
direction clrcult —_semi-closed circuit —_semiclosed
clreuits circuits
Si0B AtoB StoA BIoA
clockwise A blocked B blocked _
anti SoA BIOAS10B AtoB
clockwise _B blocked A blocked
Pressure regulation only available with clockwise rotation
and clockwise swivel angle.
Brueninghaus Hydromatix