Sunteți pe pagina 1din 20
RE 92450/00.83 MANNESMANN Variable Displacement Pump A2V RE ROT Series 5, for open, closed and semi-closed circuits Axil psion unt, bent axis design ai 92450/09.83 Brueninghaus Hydromatik ‘Sizes 250.,.1000 High pressure range up replaces 01.82 Description ‘Axial piston unit of bent axis design with variable dis- placement, for hydrostatic drives in closed and semi- ‘closed, and open circuits, Maximum flow is proportional to the drive speed an dis- placement and is infinitely variable at constant drive ‘speed. ‘Comprehensive control programme for every control and regulating function. ‘Special Features of Series 5: New, simplified high performance rotary group with en- hanced technical data and well-oroven spherical con- trol area. Section Housed pump for closed circuit Heavy duty rolling bearings for intermittent high pres- sure operation. For continuous duty at high pressures, hydrostatic bea- rings are available. ‘Operation on fire-resistant tlulds is possible (please ‘consult us). Improved port plate design and compact design redu- ‘ces noise level by 5 dBA. ‘Complete primary units with all auxiliary devices for closed circuits (see RE 93700). ie Brueninghaus Hycromatik 1 RE 92450/09.83 ‘Variable Displacement Pump A2V (Series 5) short code Ordering Code azv|s00}ov| Gc | R| 5 |G] P {tnd Pump Type To ____shattend Axial piston keyed shaft eee acomont EZ] wed on = plined shat Size Design aa) @ submersible pump Ce] jm Sie (= displacement Ge ‘sizes 250 — 1000 terme Range sounting howe pune Teen ass fange mounting sizes 2 — 107 sie 500 and 100 Seohe aa feat mounting Size 2000 ~ on enauiry oer Contot Device —— series A Direction of Rotation (Wlowed on drive shaft) clockwise oz without control hydraulic contrat pressure related ‘Adaltional functions: Constant HP control (L) anti-clockwise Electrical control (RMVB) Pressure regulation (DAS) Type of Circult (Details in clear text) closed circuit & hydraviie contro! CW) servo stom somi-closed circuit, CH] hysrautic contot CR] pon creat = CY flow related hydraulic control flow related Design E fortitingot = CS] for fitting of servo valve and bypass valve sisctonic conver CED] elestonie cont EO with bypass valve Ea etociric conto [EC] electro-mechanical handwhee! control [MA] pressure regulator, hydraulically operated with pressure Unloading with two point sem closed clreult Control Sith two point conto! AH] oe poo waa ieee 7 wt we ‘ | "H Point control e Os pressure regulator, J L slectro-nydraulically kt operated ‘open circuit AB service ports $ suction port Ordering Example A2V.500.0V.G.R.5.6.P A.B additional ports + Gil rain Variable displacement pump A2V, size 600 without control de- Ky, KK flushing ports VU flushing port vice, closed clrcult, clockwise rotation, series 5, design G,ke- case drain (for flushing of yed ‘shaft My Mp gauge connections bearings) 2. Brueninghaus Hydromatik Variable Displacement Pump A2V (Series 5) Technical Data Inlet Pressure Minimum pressure at port § (suction inlat) Pre 08 bar Prax (S88 case pressure) ‘The boost prassure ina closed circuit Is set at 16 bar. Outlet Operating Pressure Pressure at ports A or B Rated pressu Peak pressure (Pressure data to DIN 24312) ‘With pulsating pressures in excess of 315 bar, we reaommend using splined shafts to DIN 5480. Py 350 bi Prnex 400 bar Case Pressure Maximum permissible pressure In pump casing Prax at bar abe, ‘The permiasible preasure Is, however, dependent on speed. ‘Standard shaft seal ‘Size 956 Size 250 8 é t * ~ 3 £3 £2 - 3 I || & 0 1000 2000 2500 ‘Speed n (7pm) —m ‘A higher case drain pressure Is possible by fitting glide ring seals — soe RE 94104, When ordering state in clear text "with lide ring seal Mounting position: Optional. (use case drain port at highest point). The pump housing must always be filled with ol Hydraulic Fluid Operating Viscosity Range inorder to obtain optimum efficiency and service life, we re ‘commend that the operating viscosity (at operating temper ture) be selected in the range. Yenr= optimum operating viscosity 16..96 mm/s {as referred to the circult temperature in closed circuits and the tank temperature in open circuits. Viscosity Limits ‘The following values are valid for extreme operating condi tions: 10 mm/s for short periods with a max. permissible leakage oll temperature of 90° C, nx = 1000 min/s for short periods upon cold start. Prior to project design, please see our data shoot RE 90220 for detailed information on the selection of fluids on an mineral oll base and application conditions. RE 92450/09.83 Selection Diagram Notes on Selection of the Hydraulle Fluld For correct selection of the hydraulic fluld, know the operating temperature in relation to the ambient temperature: In closed clrcults this Is the circuit temperatu In open circuits the tank temperature, ‘The fluid should be selected so that in the operating tempera ture range the operating viscosity lies within the optimum ran- (ay) (808 shaded section of selection diagram), We recom- mend thatthe higher viscosity grade be selected in each case. Example: At an ambient temperature of X° G, the operating ‘temperature in the clrouit is 60° C. Within the optimum visco: sity range { vay ; shaded section) this corresponds to viscost ty grades VG 46 and VG 68. VG 68 is selected. Note: The leakage oll temperature is influenced by pressu- ‘eand speed and is always higher than the cireult or tank tem- perature. It must not be allowed to increase beyond 20° C. If 111s not possible to maintain the above conditions because fof extreme operating parameters or high ambient temperatu- res, we recommend flushing of the bearings via port U. Flushing flows size sq Vinin 250 355 500 1000 125 16 25 40 Temperature of flushing fluid < tank temperature When using water-based and synthetic fluids, see our data shoot RE 90223, Filtration Recommended filtration 10 micron Coarser filtration of 25 — 40 microns is possible, but longer ‘component Ife will be achieved using 10 micron f to lower component wear. Direction of Flow Through Pump ‘Anti-lockwise rotation Clockwise rotation Swivel open closed and open closed and direction clrcult —_semi-closed circuit —_semiclosed clreuits circuits Si0B AtoB StoA BIoA clockwise A blocked B blocked _ anti SoA BIOAS10B AtoB clockwise _B blocked A blocked Pressure regulation only available with clockwise rotation and clockwise swivel angle. Brueninghaus Hydromatix

S-ar putea să vă placă și