Documente Academic
Documente Profesional
Documente Cultură
Section ISLĆ549Ći30Ć203
Equipment Issue 3
030Ć101290 Rev. C August 2002
Westell INTELIPORTr SL
2W/4W SHORTĆLOOP DATA STATION TERMINATION
MODEL ISL5490i3 (ISSUE 3)
CLEI* Code: NCDSFGP1AA
CONTENTS PAGE #
1. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3. CIRCUIT & FUNCTIONAL OPERATION . . . . . . . . . 2
4. INSTALLATION INFORMATION . . . . . . . . . . . . . . . . 8
TEST
5. TESTING & TROUBLESHOOTING . . . . . . . . . . . . . 10
ISL5490 ISS.3
INTELi pORT SL
6. CUSTOMER & TECHNICAL SERVICES . . . . . . . . 11
7. WARRANTY & REPAIRS . . . . . . . . . . . . . . . . . . . . . . 11
8. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9. ACRONYMS & ABBREVIATIONS . . . . . . . . . . . . . . 13
Ć NOTE Ć
Hereafter, the Westell Westell ShortĆloop Data Station TerĆ
mination module, INTELIPORT SL, Model ISL5490i3 will 1.4 Product Mounting
be referred to as the ISL5490i3" or the INTELIPORT."
The ISL5490i3 module can be mounted into Westell's DAS290
for single module installation, Westell's USA preĆwired
1.2 Document Status 500Ćtype shelf assembly, Westell's unĆwired 500Ćtype shelf asĆ
sembly, or a standard 400Ćtype shelf assembly.
Whenever this document is updated or revised, the reason will
be stated in this paragraph. The ISL5490 changes to 200MeĆ 1.5 Product Features
chanicsr platform with Issue 3. Revison A created this
The ISL5490i3 module offers the following features.
document. Revision B updates the Applications section. ReviĆ
sion C updates Figure 2 and Table 4.
S Operates in either 2W or 4W data modem applications.
ECopyright 2002 Westell, Inc. All rights reserved. Printed in the United States of America. 0208I3RC
*CLEI is a trademark of Telcordia Technologies.
200 MECHANICSr and INTELIPORTr are registered trademarks of Westell, Inc. Page 1 of 14
Section ISLĆ549Ć0i3Ć203 030Ć101290 Rev. C R
S Automatically adjusts receive path for proper level coorĆ 2.2 The INTELIPORT SL incorporates a command mode
dination between facility and data modem with respect to in which all functions, except manual and toneĆactivated loopĆ
TLP (Transmission Level Point) or DLP (Data Level back, are accessed. The command mode is the operational state
Point). in which ISL5490i3 monitors its transmission ports of incoming
frequencies and interprets these frequencies as commands to
carry out a specific function. The command mode is remotely acĆ
S FourĆtone autoĆsweep or fullĆrange transponder operaĆ
tivated from the STC by sending 2713Hz to INTELIPORT's
tion with quiet termination mode permits remote testing
RCV IN port for more than 30 seconds. After meeting this reĆ
of noise and tone level measurements; Also provides quirement, INTELIPORT sends a steady 1008Hz tone at
4Ćtone, 0 dB auto transponder over RCV IN port. +5dBm (TLP)indicating command mode initiation. The STC,
at this point, can remove the 2713Hz tone.
S Front panel TEST switch used to manually activate INĆ
TELIPORT's test mode for verifying station wiring or to 2.3 While in the command mode, the STC can access any
manually activate INTELIPORT's autoĆalign feature. one of INTELIPORT's intelligent functions which include
S Acknowledgement tone (alternating 1008/2808 Hz) idenĆ S toggling from TLP reference to DLP (data level) referĆ
tifies unit as INTELIPORT when circuit is accessed. ence,
Ć NOTE Ć
S 7Ćyear warranty. To exit the command mode and return to idle, the STC
sends a second 2713Hz tone for five seconds or longer.
2 0208I3RC
0208I3RC
RT 600
7 DRT
5
R
RCV LEVEL 2W/4W
CIRCUITRY CIRCUITRY
X LB
RR 600
DRR
13 15
2713Hz TEK5
RCV DATA
FILTER AND 23
DETECTOR
DETECTOR LB
TEK6
030Ć101290 Rev. C
LPBK 21
TLP/DLP AMP
TOGGLE
LB MNLB
RELAY 1
TEST
SC
PWR
MICROPROCESSOR
PWR
SEALING POWER QUERY 35
CURRENT DETECTOR
POWER
(1304Hz) SUPPLY GND
17
4W 2W
RCV XMT ALIGN/ FAIL/ MLBG
OSCILLATOR 19
LPBK TEST
HYBRID
(308Hz – 3208Hz)
TRANSPONDER
ELECTRONIC CIRCUITRY
SWITCH
4–TONE AUTO
CIRCUITRY
OR
FULL RANGE
Section ISLĆ549Ć0i3Ć203
LB
TT 600
41 DTT
55
X LB
XMT XMT CUT 2W/4W
PAD CIRCUITRY CIRCUITRY
TR 600
47 DTR
XMT DATA 49
DETECTOR
3.1 LED Status Indicators matically times out one hour after the initial activation or the
STC can release the test mode by sending 2713Hz, 10 to 60 minĆ
INTELIPORT is equipped with six frontĆpanel LEDs that proĆ utes after initial activation.
vide a quick visual indication to the status and mode. Table 1
summarizes the LED functions. Ć NOTE Ć
If the TEST switch is pressed and held for longer than five seconds
LED ON OFF FLASHING but less than 10 seconds, INTELIPORT recognizes this as a comĆ
PWR Power No NA mand to enter the DST to ETO AUTOĆALIGN sequence (see
Applied Power
paragraph 3.18, 3.19, and 3.21). If the TEST switch is pressed
and held for longer than 10 seconds, INTELIPORT recognizes
SC Sealing No Sealing NA
this as a command to enter the DST to DST AUTOĆALIGN seĆ
Current Current
quence (see paragraph 3.17, 3.20, and 3.21).
Present
ALIGN/LPBK Command/ Idle Loopback Mode
PORT 4W 2W
(See Note) Alignment/ (See Note)
Transponder RCV IN Continuous 1008Hz Continuous 1008Hz
Mode (See Note 1) (See Note 1)
RCV OUT Continuous 1008Hz See NOTE 1 & 2
FAIL/TEST Logic Failure Idle Test/Align Mode (See Note 1)
(See Note) Mode (See Note) XMT IN Interrupted 1008Hz Continuous 1008Hz
XMT Receiving No Data Receiving Data (See Note 1)
Data From From XMT OUT Interrupted 1008Hz Interrupted 1008Hz
Equipment Equipment
Table 2. INTELIPORT ISL5490i3 Wiring Test Mode
RCV Transmitting No Data Transmitting
Data To Data To
Equipment Equipment Ć NOTE Ć
Table 1. INTELIPORT ISL5490i3 LED Status Indication Pressing the TEST switch for greater than 1.5 but less than
5 seconds, causes steady 1008 Hz tone to be applied to the
RCV transmission ports for 10 minutes. After 10 minutes,
Ć NOTE Ć the steady 1008Hz changes to interrupted 1008Hz (Approx.
When a DST to ETO AUTO ALIGN is initiated via the TEST 4 sec ON; 1 sec OFF. In 2W applications, the RCV OUT and
switch (i.e. TEST switch pressed for >5 but <10 seconds), the XMT IN ports utilize the same transmission pairs (XMT
ALIGN/LPBK and FAIL/TEST LEDs will light steady. IN). Therefore, interrupted 1008Hz (Approx. 1/2 sec ON;
Upon releasing the TEST switch before 10 seconds has 1/2 sec OFF) will be present.
elapsed, the ALIGN/LPBK and FAIL/TEST LEDs will reĆ
main on, steady. When DST to DST AUTO ALIGN is
initiated via the TEST switch (i.e., TEST switch pressed for 3.3 Command Mode
>10 seconds), the ALIGN/LPBK and FAIL/TEST LEDs
will flash. Upon releasing the TEST switch after 10 seconds The command mode is activated from the STC by sending
has elapsed, the ALIGN/LPBK and FAIL/TEST LEDs will 2713Hz to the RCV IN port (pins 7 and 13) for more than 30 secĆ
light steady.
onds. INTELIPORT sends steady 1008Hz at the XMT OUT
port (pins 41 and 47) indicating command mode initiation.
3.2 Wiring Test Mode
Ć NOTE Ć
Once the installer connections are complete and the unit is If 2713 Hz is present for more than 1.5 seconds but removed in
installed, it is recommended that the installer manually activate less than 30 seconds, INTELIPORT enters loopback.
INTELIPORT's test mode to verify installation and station wirĆ
ing. Pressing the recessed pushĆbutton TEST switch, located on
INTELIPORT's front panel, for greater than 1.5 but less than 3.4 2W/4W Option Setting
five seconds (see the following NOTE) causes the FAIL/TEST
LED to flash and steady 1008Hz to be applied to the RCV transĆ The 2W/4W option setting is a hardware switch selection on the
mission ports (both the line side and drop side) and interrupted printed circuit board, set at the time of installation. The
1008Hz (approximately 1/2 OFF; 1/2 second ON) on the XMT ISL5490i3 is a factory set for 4Ćwire and needs to be reset for
transmission ports. After 10 minutes, the steady 1008Hz on the 2Ćwire circuit applications.
RCV transmission port changes to an interrupted 1008Hz tone
(approximately 4 seconds ON; 1 second OFF). Station wiring is 3.5 TLP/DLP Toggle
verified by connecting a Transmission Test Set with a builtĆin
speaker or other suitable listening device to the receive and INTELIPORT is initially programmed to align and transpond at
transmit channel pairs at the cable connection and demarcation TLP. This feature can, however, be programmed to have the unit
points, and listening for the appropriate tones. Refer to Table 2 align and transpond at DLP (data level). Toggling from TLP to
for a summary of the INTELIPORT's RCV and XMT tones DLP is accomplished while in command mode by sending
when operating in 2W or 4W applications. After verifying the 2804Hz. Upon detecting 2804Hz, INTELIPORT toggles to the
tones, press the TEST switch again to end the test mode. If the DLP mode, corrects the internal circuitry to accommodate the
TEST switch is not pressed a second time, the test mode autoĆ change in levels, then returns to command mode. Toggling is verĆ
4 0208I3RC
R 030Ć101290 Rev. C Section ISLĆ549Ć0i3Ć203
ified by monitoring the level for a change of 13dB. To return to tone (see paragraph 3.9). Please note that during 3Ćtone alignĆ
TLP, the STC sends another 2804Hz. ment, the 60Ćsecond time out feature can be bypassed by sending
1004Hz within the 60Ćsecond time frame.
Ć NOTE Ć
Each time INTELIPORT returns to idle, the TLP/DLP circuit 3.8 Remote 1ĆTone Quick Alignment
automatically returns to the TLP mode. Therefore, whenever
While in command mode (1008Hz present), the STC should reĆ
the command mode is reĆassessed from an idle state and testĆ
ing or alignment is to be done at data level, the STC must send cord the level received, then initiate the quick alignment mode
2804Hz to toggle the DLP mode. by sending 1004Hz to INTELIPORT. Upon detecting 1004Hz,
INTELIPORT sends 2808Hz. The STC should record the level
received, then remove 1004Hz being sent to INTELIPORT.
3.6 Alignment Upon detecting removal of 1004Hz, INTELIPORT sends either
a rampĆup tone or a rampĆdown tone.
INTELIPORT features both remote and automatic alignment
capability with respect to either 3 or 4 tones. Remote alignment
is used to align the ISL5490i3 and is activated from the STC,
3.9 RampĆUp/RampĆDown Tone Sequence
while in command mode, by sending 1004Hz (see paragraph Once the levels are set, INTELIPORT sends a rampĆup or rampĆ
3.7). The STC can also align the ISL with respect to 1004Hz only down tone sequence. The rampĆup sequence, consisting of a
(i.e., 1Ćtone quick alignment, see paragraph 3.8). Automatic series of tones ranging from 308Hz to 3008Hz in ascending orĆ
alignment is used to align INTELIPORT with the distant end in der, indicates alignment is within 0 to 4dB of cable loss. The
a pointĆtoĆpoint application and is activated from the STC, while rampĆdown sequence, consisting of a series of tones ranging
in command mode, by sending 1804Hz (see paragraph 3.18). In from 3008Hz to 308Hz in descending order, indicates alignment
either the remote or automatic alignment mode, INTELIPORT is greater than 4 dB of cable loss. The tone sequence is applied
automatically adjusts the gain for proper level coordination. INĆ for approximately 1.5 seconds with the last tone (3008 Hz in the
TELIPORT is initially programmed to align at TLP, but can be rampĆup; 308 Hz in the rampĆdown) being applied for approxiĆ
programmed to align at data level (DLP) (see paragraph 3.5). mately 5 seconds. After 5 seconds, INTELIPORT enters
When programmed to align at TLP, INTELIPORT outputs is reĆ loopback.
spective tones at +5 dBm. When set to align at DLP,
INTELIPORT outputs is respective tones at Ć8 dBm. The operĆ 3.10 Loopback
ating levels for the ISL5490i3 are given in Table 3.
While in loopback, the receive path is interconnected to the
Ć NOTE Ć transmit path via a loopback amplifier and allows the STC to
DST to ETO AutoĆAlign can be activated from an onĆsite locaĆ verify alignment settings and facility frequency response. The
tion by pressing the TEST switch for longer than five seconds loopback circuit automatically inserts 16dB of gain to provide an
but less than 10 seconds. DST to DST AutoĆAlign can be actiĆ equalĆlevel loopback condition. During loopback, the STC
vated from an onĆsite location by pressing the TEST switch for sends tones (404, 1004, 1804, and 2804Hz), one at a time, to INĆ
longer than 10 seconds. TELIPORT. The STC should verify/record the level of each tone
as it is looped back by INTELIPORT.
LEVELS (IN DBM)
PORT TLP DLP
3.11 Loopback Release
RCV IN +5 to Ć10 Ć8 to Ć23 Loopback is equipped with an automatic time out feature that
RCV OUT Ć3 Ć16 releases the loopback condition 20 minutes after initial activaĆ
XMT IN +13 0 tion. If release from loopback is desired before the 20Ćminute
XMT OUT +5 Ć8 time frame, it can be accomplished by sending 2713Hz for 0.9
seconds, or longer then removing the tone. Loopback releases
Table 3. INTELIPORT ISL5490i3 Operating Levels
when 2713Hz is detected. The automatic time out release feaĆ
ture ensures restoration of the transmission paths in the event
3.7 Remote 3Ć or 4ĆTone Alignment the 2713Hz tone is not sent. Loopback can be initiated any time
the unit is idle by applying 2713 Hz for a period greater than 2.5
While in command mode (1008Hz present), the STC should reĆ seconds but less than 30 seconds. INTELIPORT returns an alĆ
cord the level received, then initiate the alignment mode by ternating 1008/2808 Hz indicating the circuit accessed for
sending 1004Hz to INTELIPORT. Upon detecting 1004Hz, INĆ testing as Westell's ISL5490i3, ShortĆloop DST intelligent unit.
TELIPORT sends 2808Hz. The STC should record the level
received, then send 2804Hz to INTELIPORT. Upon detecting Ć NOTE Ć
2804Hz, INTELIPORT sends 408Hz. The STC should record If 2713 Hz is present for more than 30 seconds, INTELIPORT
the level received, then send 404Hz to INTELIPORT. Upon deĆ enters the command mode.
tecting 404Hz, INTELIPORT sends 1808Hz for 60 seconds. The
STC should record the level received, and then either send 3.12 Manual Loopback Activation
1804Hz to INTELIPORT before 60 seconds times out (perĆ
forming a 4Ćtone alignment), or ignore the tone (performing a Manual loopback activation can also be accomplished by placing
3Ćtone alignment). Upon completion, INTELIPORT sets the a ground on the MNLB lead, pin 1. When manually activated,
gain required and returns either a rampĆup tone or a rampĆdown neither automatic time out nor detection of 2713Hz will effect
0208I3RC 5
Section ISLĆ549Ć0i3Ć203 030Ć101290 Rev. C R
loopback release. Release of a manually activated loopback conĆ 3.17 FullĆRange Transponder
dition can only occur by removing the ground.
To activate the fullĆrange transponder, the STC sends any tone
from 304Hz to 3804Hz (except 400Hz, 2600Hz and 2700Hz). As
3.13 4ĆTone AutoĆSweep (RCV IN Port) tone is received, INTELIPORT responds by sending a similar
tone (but at an offset) for the same duration tone is received
INTELIPORT features a 4Ćtone automatic sweep transponder from the STC or 15 seconds (whichever is longer). Each tone
mode that allows for a quick level verification test over the reĆ transmitted by the STC is sent in increments of 100Hz. Upon
ceive in port. To activate this 4Ćtone auto sweep, the STC sends completion and if no other tone is sent by the STC, INTELIĆ
604Hz while in command mode. Upon detecting 604Hz, INTEĆ PORT reapplies quiet termination and resets the 20 minute
LIPORT sends 1008Hz for 60 seconds, followed by 60 seconds timer circuit. If no tone is sent within the 20Ćminute time frame,
of quiet termination, then begins a sweep at tones of 408Hz, INTELIPORT times out and returns to idle. To release and reĆ
1808Hz, and 2808Hz at 0dBm, each for 30 seconds, then returns turn to command mode before the 20Ćminute time out, the STC
to command mode. sends 2604Hz for five seconds, or longer. INTELIPORT sends
an interrupted 1008Hz tone and returns to command mode. To
Ć NOTE Ć release and return to idle before the 20Ćminute time out, the
To bypass the 60Ćsecond quiet termination portion and quickly STC sends 2713Hz for five seconds, or longer.
enter the autoĆsweep portion of the test, the STC sends 1004 Hz
for five seconds, subsequently removing the tone. To abort this test 3.18 AutoĆAlign
and return to command mode, the STC sends 2604 Hz (during
quiet termination only) for longer than five seconds, subsequently AutoĆAlign is used to align INTELIPORT with the distant end
removing the tone. in a pointĆtoĆpoint application and can be initiated remotely
from the STC while in command mode (see paragraph 3.21).
3.14 Quiet Term/Transponder
Ć NOTE Ć
INTELIPORT incorporates a quiet term/transponder mode of AutoĆAlign can also be initiated from an onĆsite location by pressĆ
operation that allows the STC to remotely conduct noise and ing and holding the TEST switch. The TEST switch, however,
should be pressed only when instructed; otherwise pressing this
tone level measurements. While in the command mode, the STC
switch at an inappropriate time may cause circuit disruption.
activates the quiet term/transponder by sending 404Hz. Upon Please also note that when autoĆalign is initiated via the TEST
detecting 404Hz, INTELIPORT applies a quiet termination at switch, alignment at TLP takes place.
the XMT IN port and isolates signals from the data modem.
During quiet termination, the STC performs noise measureĆ
ments. Quiet termination remains in affect for 20 minutes or
3.19 DSTĆETO Alignment Via TEST Switch
until another tone (to enter the transponder operation or return When the TEST switch is pressed and held for more than 5 secĆ
to command mode) is sent. Please note that if no tone is sent onds but less than 10 seconds (the FAIL/TEST and
within the 20Ćminute time frame, INTELIPORT times out and ALIGN/LPBK LEDs will light steady), INTELIPORT recogĆ
returns to idle. Escape to command mode can also be done by nizes this as a command to perform a DST to ESO alignment.
sending 2604Hz for more than five seconds, subsequently reĆ When activated, INTELIPORT outputs 2913Hz via the RCV IN
moving the tone. INTELIPORT sends an interrupted 1008Hz port (i.e., reversed) to Station Z (see paragraph 3.21).
tone and returns to command mode. Escape to idle can also be
done by sending 2713Hz for more than five seconds. 3.20 DSTĆDST Alignment Via TEST Switch
When the TEST switch is pressed and held for more than 10 secĆ
3.15 Transponder Operation
onds (the FAIL/TEST and ALIGN/LPBK LEDs will flash),
INTELIPORT recognizes this as a command to perform a DST
INTELIPORT features a 4Ćtone automatic sweep transponder
to DST alignment. When activated, INTELIPORT outputs
mode and a full range transponder mode of operation. The
2713Hz via the XMT OUT port to Station Z (see paragraph
4Ćtone autoĆsweep transponder allows for a quick level verificaĆ
3.21).
tion test over the transmit port. The fullĆrange transponder
allows for a more detailed level verification test over a range of
frequencies from 304Hz to 3804Hz over the transmit port. Both 3.21 Alignment Via Command Mode
transponder modes are activated from the quiet termination While in command mode and before autoĆalign is initiated, the
mode only. STC must decide if alignment is to be done at TLP or DLP (see
paragraph 3.5). To activate autoĆalign from the command mode,
3.16 4ĆTone AutoĆSweep the STC sends 1804 Hz.
6 0208I3RC
R 030Ć101290 Rev. C Section ISLĆ549Ć0i3Ć203
TEST
ISL5490 ISS.3
INTELi pORT SL
4W 2W
S3
XMT RCV FAIL ALIGN SC PWR
TEST LPBK
ing pressed and held for longer than five but less than 10 seconds 3.22 Align Query Mode
(DSTĆETO Align); via detection of the TEST switch being
pressed and held for longer than 10 seconds (DSTĆDST Align); The alignment query mode permits the STC to verify whether
or via detection of 1804Hz from the STC), sends 2913Hz to StaĆ INTELIPORT returned the rampĆup tone sequence (indicating
tion Z for 60 seconds via the RCV IN port. After 60 seconds, alignment is within 4 dB of cable loss) or the rampĆdown tone
2913Hz is removed. If a command mode tone from the distant sequence (indicating loss is greater than 4 dB). The alignment
end is detected (i.e., 1004Hz, ±1%), Station A assumes the disĆ query mode is activated from the command mode by sending
tant end (Station Z) is an intelligent 4W ETO and automatic 1204 Hz. Upon detecting 1204 Hz, INTELIPORT returns the
alignment continues. If command mode tone is not detected afĆ rampĆup or rampĆdown tone, then returns to command mode.
ter sending 2913Hz, Station A sends 2713Hz for 60 seconds via
the XMT OUT port. If a command mode tone from the distant 3.23 Sealing Current
end is detected at this point, automatic alignment continues.
Sealing current is recommended on all metallic facilities to help
prevent transmission path noise. Sealing current is a lowĆvalue
Ć NOTE Ć DC current (approx. 20mA) applied to the 4Ćwire dry cable
If no response from 2913 Hz/2713 Hz is detected, Station A reĆ pairs, on a simplex basis, to break down resistance which may
sends 2713 Hz (more than five seconds) and returns to idle. build up at nonĆsoldered cable splices. Continuous application
of sealing current helps prevent degradation of transmission
With both stations set, tones are automatically sent and received performance. The internal sealing current circuit provides a curĆ
between both ends. Upon completion of the last tone and detecĆ rentĆlimiting load to the simplex leads when sealing current is
tion of the rampĆup or rampĆdown tone sequence supplied from the distant end. The SC LED will light when sealĆ
(approximately two to three minutes), Station A reĆsends ing current is present.
2913Hz (if the unit at the distant end is an intelligent ETO) or
2713Hz (if the unit at the distant end is an intelligent DST) and 3.24 Power Query Mode
returns to idle. Station Z, upon detecting 2913Hz (for an ETO)
or 2713Hz (for a DST), also returns to idle. Gain is automatically INTELIPORT provides a power query mode that permits the
set and alignment is complete. STC to verify the status of the power supply to determine if powĆ
er was interrupted for whatever reason. The power query mode
is activated by sending 1304 Hz while in command mode. Upon
Ć NOTE Ć
detecting 1304 Hz, INTELIPORT returns either a rampĆup
If, at the end of the alignment (DSTĆDST or DSTĆETO), INTEĆ tone (308 Hz to 3008 Hz) indicating power has not been interĆ
LIPORT determines that the loop is more than 4 dB, the FAIL/ rupted since last alignment or query or a rampĆdown tone (3008
TEST and ALIGN/LPBK LEDs will flash (alternately) for five
Hz to 308 Hz), indicating an interruption in power has occurred.
minutes. This indication lets the installer know to check the
equalization to verify that the circuit meets specification. After the rampĆup or rampĆdown tone, INTELIPORT returns
to command mode.
0208I3RC 7
Section ISLĆ549Ć0i3Ć203 030Ć101290 Rev. C R
Ć CAUTION Ć
Ć CAUTION Ć Do not apply power until all wiring and installation is
The test switch should be pressed only when instructed; complete.
otherwise pressing this switch at an inappropriate time
may cause circuit disruption.
Ć CAUTION Ć
Use care when installing and removing modules Ć do not force
a module into place. If a module resists insertion, remove it and
check for obstructions in or near the module's or shelf's
connectors and mounting slots. The module may then be
4. INSTALLATION INFORMATION carefully aligned and gently reĆinserted.
8 0208I3RC
R 030Ć101290 Rev. C Section ISLĆ549Ć0i3Ć203
Press TEST switch to end test mode. Verify FAIL/TEST LED off.
3. Test Center's Procedures Command Mode: If 2713 Hz is present for >1.5 seconds
Send 2713 Hz (>30 seconds). INTELIPORT returns 1008 Hz at +5 dBm (TLP). STC but <30 seconds, the INTELIPORT
removes 2713 Hz. Command mode initiated. NOTE: If 2713 Hz is present for >1.5 enters loopback.
seconds but <30 seconds, INTELIPORT enters loopback.
4. TLP/DLP: INTELIPORT automatically returns to
Perform this step only if aligning at DLP. INTELIPORT is initially set to align at TLP. From TLP mode whenever unit returns to idle.
command mode, send 2804 Hz. INTELIPORT toggles to DLP mode, then returns to Therefore, when aligning at DLP, unit
command mode. Toggling is verified by monitoring level for a change of 13 dB. To must be reset to DLP mode.
toggle back to TLP, send another 2804 Hz.
5. Remote 3Ć or 4ĆTone Alignment: The 60Ćsecond timer circuit can be
From command mode (1008 Hz present), record level received, then send 1004 Hz to bypassed by sending 1004Hz.
INTELIPORT.
INTELIPORT sends 2808Hz. Record level received, then send 2804 Hz to INTELIPORT.
INTELIPORT sends 408Hz. Record level received, then send 404 Hz to INTELIPORT.
INTELIPORT sends 1808Hz for 60 seconds. Record level received. STC now has option:
ĆSend 1804Hz within 60 seconds. INTELIPORT aligns to 4 tones, sends
rampĆup/rampĆdown tone, then enters loopback.
ĆIgnore 1804Hz. 1808Hz tone times out after 60 seconds. INTELIPORT aligns to 3 tones,
sends rampĆup/rampĆdown tone, then enters loopback.
6. Remote (Manual) 1ĆTone Alignment: None
From command mode (1008Hz present), record level received, then send 1004 Hz to
INTELIPORT. INTELIPORT sends 2808Hz. Record level received, then remove 1004Hz to
INTELIPORT. INTELIPORT aligns to 1004Hz tone, sends rampĆup/rampĆdown tone, then
enters loopback.
7. Loopback: None
While in loopback, STC sends tones (404,1004, 1804 and 2804Hz), one at a time, to
INTELIPORT. The STC should record the level of each tone as it is looped back by
INTELIPORT.
Relaease from loopback. Loopback is equipped with an automatic timeĆout feature that
releases the loopback condition after 20 minutes. INTELIPORT returns to idle. If release
is desired before the 20Ćminute time frame, STC can send 2713 Hz (0.9) sec, or longer).
INTELIPORT returns to idle upon detecting 2713 Hz.
Table 5. INTELIPORT ISL5490i3 Testing and Alignment Procedures
0208I3RC 9
Section ISLĆ549Ć0i3Ć203 030Ć101290 Rev. C R
From command mode, send 404 Hz. INTELIPORT applies quiet termination at the XMT
IN port and sets 20Ćminute timer. STC performs noise measurements. Quiet termination
remains in affect for 20 minutes or until another tone is sent (i.e., enter 4Ćtone auto or
fullĆrange transponder, or exit and return to command mode). If no tone is sent within the
20Ćminute time frame, INTELIPORT times out and returns to idle.
10 0208I3RC
R 030Ć101290 Rev. C Section ISLĆ549Ć0i3Ć203
6. CUSTOMER & TECHNICAL SERVICES for any reason other than abuse, improper use, or improper
installation. Before returning the defective equipment, first reĆ
6.1 Customer Service & Technical Assistance quest a Return Material Authorization (RMA) number from
Westell. Once an RMA number is obtained, return the defective
If technical or customer assistance is required, contact Westell unit, freight prepaid, along with a brief description of the probĆ
by calling or using one of the following options: lem, to:
0208I3RC 11
Section ISLĆ549Ć0i3Ć203 030Ć101290 Rev. C R
12 0208I3RC
R 030Ć101290 Rev. C Section ISLĆ549Ć0i3Ć203
0208I3RC 13
14
START YES NO
SEND IS TONE PRESENT INTELIPORT SENDS IS TONE PRESENT INTELIPORT SEND TONES, ONE RECORD LEVEL OF
2713Hz FOR MORE THAN 1.5 ALTERNATING FOR MORE THAN 30 ENTERS AT A TIME, TO EACH TONE LOOPED
SECONDS ? 1008/2808Hz (<1 SEC.) SECONDS ? LOOPBACK INTELIPORT BACK BY INTELIPORT
NO YES TO RELEASE,
INTELIPORT SEND 2713Hz
REMAINS IDLE ( >0.9 SEC.)
Section ISLĆ549Ć0i3Ć203
TLP/DLP
INTELIPORT TOGGLES BETWEEN INTELIPORT ALIGNS TO 4 TONES,
INTELIPORT RETURNS SEND 1804Hz
SEND TLP AND DLP. VERIFY BY SENDS RAMP–UP/RAMP–DOWN
TO COMMAND MODE
2804Hz MONITORING 1008Hz LEVEL TONE, THEN ENTERS LOOPBACK
AFTER TOGGLING
FOR CHANGE OF 13dB
SEE NOTE 2
0208I3RC