96M11286

Connecting the Cable

 VT3 handy series unit


Touch Panel Display 1 Loosen the seven screws on the cable cover of the VT3 Handy Series unit, and

VT3 Handy Series Connection


remove the cable cover. (The screw is a captive screw and will not come off com-
pletely.)

Cable Point Small screws with rubbers do not need to be loosened.

Instruction Manual
Refer to the "VT3/DT Series PLC Connection Manual" for information on settings related to con-
necting with external devices.
Refer to the "VT3 Handy Series Instruction Manual" or "VT3 Series Hardware Manual" for infor-
mation on the input/output specifications and grounding.

Types of Cables

OP-87180 / 87181 . . . . . . . . . . KV Series programming console connection cable (3 m / 5 m)

2 Connect the middle connector (CN1) while paying attention to the orientation.

OP-87182 / 87183 . . . . . . . . . . Mitsubishi Q Series [Q Mode] programming console connec-


tion cable (3 m / 5 m)
OP-87184. . . . . . . . . . . . . . . . . . Mitsubishi FXN Series programming console connection cable
(5 m)

3 Connect the right connector (CN3) while paying attention to the orientation.
OP-87185 / 87186 / 87187 . . . . RS-232C / 422 connection cable (3 m / 5 m / 10 m)

* RS-485 communication is not possible.

OP-87188 / 87189 / 87190 . . . . Ethernet connection cable (3 m / 5 m / 10 m)

4 Connect the left connector (CN2A [left]: RS-232C or CN2B [right]: RS-422) while pay-
ing attention to the orientation.

There is no CN2 for the Ethernet connection cable so it cannot be con-


Point nected.
OP-87191 / 87192 / 87193 . . . . RS-232C / 422 / 485・Ethernet connection cable (3m/5m/10m)

*Terminator switch
OP-87194 / 87195 / 87196 . . . . Cable with removal connector (3 m / 5 m / 10 m)

* When using RS-422 / 485, refer to the "VT3/DT PLC Connection Manual" and set the
terminator selection switch.

5 Fit the cable bushing into the groove on the VT3 Handy Series unit.

• Align the groove ( ) on the very bottom of the main unit side with
Point the bump on the top of the cable protector when fitting.
• After fitting, the bushing should be lifted slightly off the groove.

1
6 Set the cable in the direction it will be led out, and fit the cable protector into the Cable Connection Table
guide.

 Common details for each cable


CN1
CN2A
(RS-232C)

CN2B CN3
(RS-422)

7 Attach the protector cover enclosed with the cable cover onto the side from which Connector Cable
the cable is not being led out, and then close the cover. Fix it with screws. (Tighten- Signal Input/
Signal name Wire
ing torque: 4 to 5 kgf•cm) Name abbrev. output Color Dot
diameter

(Emergency Stop) Push-button


PB1A Black 1 Load
switch 1A (b contact)

(Emergency Stop) Push-button


PB1B Black 2
switch 1B (b contact)
Output AWG26 Red
(Emergency Stop) Push-button
PB2A Black 3 Load
switch 2A (b contact)

(Emergency Stop) Push-button


PB2B Black 4
switch 2A (b contact)

PBAM/ (Emergency Stop) Push-button


Black 1 Load
TPAM switch monitor A (a contact)
Output AWG26 Pink
PBBM/ (Emergency Stop) Push-button
Black 2
TPBM switch monitor B (a contact)
CN1
Enable switch 1A
EN1A Black 1 Load
(a contact)
 Pluggable connection unit VT-T1 Enable switch 1B
(Only when using OP-87194 / 87195 / 87196) EN1B
(a contact)
Black 2
Output AWG26 Purple
 Connecting EN2A
Enable switch 2A
Black 3 Load
(a contact)

1 Disconnect the connector cap from the VT-T1 and cable with removable connec-
EN2B
Enable switch 2B
Black 4
tor. (a contact)

KSW1 Key switch 1 (left) Red 1 Load


ON
R
E

OFF
W

Load
O

KSW2 Key switch 2 (right) Output AWG26 Yellow Red 2


P

KSWC Key switch common Red 3

FSWC Function switch common None

FSW1 Function switch 1 Black 1


Load
FSW2 Function switch 2 Output AWG28 Yellow Black 2
Load
FSW5 Function switch 5 Black 3
2 Face the " " on the front of the cable connector upward, and insert the connec-
CN3
FSW6 Function switch 6 Black 4
Load

tor into the VT-T1 connector until a click is heard. Load


+24V Power input (24 V) AWG24 Brown Black 4
ON Input
R
E

OFF
W

0V Power input (0 V) AWG24 Blue Black 4


O
P

FG* Frame ground - AWG24 Green None

* The FG terminal is branched to the FG1 (power shield) and the FG2 (RS-232C / 422 shield)
on the cable side.
FG2 is present on cables equipped with CN2.

<Cable colors and dots>


Cable color (ex.) orange Cable color (ex.) pink

Dot color (ex.) black Dot color (ex.) red


 Disconnect the cables

1 Shift the side of the connector on the cable with removal connector (1) in the
removal direction, and disconnect the cable (2).
No. of dots (ex.) 2 No. of dots (ex.) 1
ON
R
E

OFF
W
O
P

(1) (2)

2
 Individual details for each cable  Using RS-232C / 422 / 485・ Ethernet connection cable
(OP-87191 / 87192 / 87193)
 Serial connection with KEYENCE PLC (using OP-87180 / 87181)
VT3 Handy Series side KV, KZ, KV-P side Connector Cable
CN2A Modular 6P View from cable Signal Input/
Orange connector side Signal name Wire
(dots: black) Name abbrev. output Color Dot
TXD 5 SD diameter
RXD 3 RD
Orange Ethernet communication
RTS (dots: red)
TX- White None
signal
CTS Output
Orange (no dots) Ethernet communication
SG 4 SG (6) (5) (4) (3) (2) (1) TX+ Blue None
signal
DTR KZ, KV side modular connector AWG26
DSR Ethernet communication
RX- Gray None
N.C. signal
Input
N.C. Ethernet communication
CN3 RX+ Brown None
signal
*Always ground FG2.
RS-485 communication Input/
A Red 1
signal A output
 Serial connection with Mitsubishi Electric PLC Q Series
(using OP-87182 / 87183) RS-485 communication Input/
B AWG26 Pink Red 2
signal B output
VT3 Handy Series side PLC side (6P) RS-485 communication
CN2A G - Red 3
signal G
View from cable
Orange (dots: black 1)
TXD 1 RD connector side
TXD/ Serial (RS-232C / 422)
Orange (dots: black 3) Black 1
RXD 2 SD TXDA communication signal
Orange (dots: red 1) Output
RTS 3 SG 5 6
Orange (dots: red 3) NC/ Serial (RS-232C / 422)
CTS 5 DR Black 2
Orange (no dots) 3 4 TXDB communication signal
SG 6 ER
1 2 RXD/ Serial (RS-232C / 422)
DTR Black 3
RXDA communication signal
DSR Input
Mini-DIN 6P
N.C. NC/ Serial (RS-232C / 422)
Black 4
N.C. RXDB communication signal

CN2A/ RTS/ Serial (RS-232C / 422)


AWG28 Orange Red 1
CN2B RTSA communication signal
Output
 Serial connection with Mitsubishi Electric PLC FX Series DTR/ Serial (RS-232C / 422)
Red 2
(using OP-87174) RTSB communication signal

CTS/ Serial (RS-232C / 422)


VT3 Handy Series side PLC side (6P) Red 3
CTSA communication signal
CN2A
View from cable Input
Orange (dots: black 1) connector side DSR/ Serial (RS-232C / 422)
TXDA 2 RXD+ Red 4
Orange (dots: black 2) CTSB communication signal
Terminator TXDB 1 RXD−
selection switch Orange (dots: black 3) Serial (RS-232C / 422)
RXDA 7 TXD+ 6 7 8
RS-422A RS-485 Orange (dots: black 4) SG - None
RXDB 4 TXD− 3 4 5 communication signal
TMC TMR Orange (no dots)
SG 3 SG 1 2
ON *Always ground FG2.
RTSA
OFF RTSB 5 Vcc Mini-DIN 8P
Orange (dots: red 3)
1 2 3 CTSA
Orange (dots: red 4)
CTSB

 Using RS-232C / 422 connection cable (OP-87185 / 87186 / 87187)

Connector Cable
Signal Input/
Signal name Wire
Name abbrev. output Color Dot
diameter

TXD/ Serial (RS-232C / 422)


Black 1
TXDA communication signal
Output
NC/ Serial (RS-232C / 422)
Black 2
TXDB communication signal

RXD/ Serial (RS-232C / 422)


Black 3
RXDA communication signal
Input
NC/ Serial (RS-232C / 422)
Black 4
RXDB communication signal

CN2A/ RTS/ Serial (RS-232C / 422)


AWG28 Orange Red 1
CN2B RTSA communication signal
Output
DTR/ Serial (RS-232C / 422)
Red 2
RTSB communication signal

CTS/ Serial (RS-232C / 422)


Red 3
CTSA communication signal
Input
DSR/ Serial (RS-232C / 422)
Red 4
CTSB communication signal

Serial (RS-232C / 422)


SG - None
communication ground

*Always ground FG2.

 Using Ethernet connection cable (OP-87188 / 87189 / 87190)

Connector Cable
Signal Input/
Signal name Wire
Name abbrev. output Color Dot
diameter

TX- Ethernet communication signal White None


Output
TX+ Ethernet communication signal Blue None
CN3 AWG26
RX- Ethernet communication signal Gray None
Input
RX+ Ethernet communication signal Brown None

3
Original Instruction

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.


11286E 1104-2 96M11286 Printed in Japan