Sunteți pe pagina 1din 1

PROJECT: KASARA TOWER 6

Wall ID #: SW-3A
UBC-97 Load Combination
DESIGN OF SHEARWALL

Service Loads:
Pdl = 24521 KN Ve = 4985 KN
Pll = 4833 KN Me = 56894 KN-m
Pel = 13839.6 KN
Member Properties
Lw = 8.00 m tw = 0.50 m
Hw = 3.00 m centc = - m

Material Properties
fc = 55.16 MPa db = 32 mm
fy = 413.79 MPa ds = 16 mm
fys = 413.79 MPa

W = ( 1.2 Pdl + 1.0 Pll ) Pu = 1.4 Pdl + 1.7 Pll


Ha = 1.1Me d = Lw - 2 * centc - lbm

1. Check whether boudary elements are required


Cv = P / 2 + Ha / d Iw = tw * ( lw³ /12 )
Tv = P / 2 - Ha / d Ag = Lw * tw

fc = Pu / Ag + Ha * 0.50 * lw / Iw fc * 0.001= 25.52 MPa


fc all = 0.20 * fc fc all = 11.032 MPa

fc * 0.2 > fc all  boundary members are required

2. Determine minimum longitudinal and tranverse reinforcements


Vu = 1.1 * Ve Acv = Lw * tw
Vua = 0.85 * Acv * fc / 6 * 1000

Vu = 5483.28 KN Vua = 4208.62 KN

Vu > Vua  shear reinforcements are required

min = 0.0025 smax = 500 mm ACI A 5.2.1


Asvmin = 0.0025 * tw * 1000²
Asvmin = 1,250.00 mm² per meter length of wall