1
Why use a Grease Interceptor?
Grease and Oil from commercial kitchens, etc.
poses a significant problem to sewage systems
and treatment facilities.
2
Who uses a Grease Interceptor?
3
Features and Benefits
4
Design & Durability
5
Size and Dimensions
MGT500 MGT700
1.6 l/sec 3.2l/sec
A 600mm 787mm
B 445mm 597mm
C 89mm 127mm
D 325mm 318mm
E 414mm 445mm
6
How does it work?
9. Surface load
1. Flow Inlet capacity = 200kg
Imperial to Metric
Use SSN Coupler 50mm
8. Water and fine
and 75mm
food particles
exit the unit
2. Solids basket,
with baffle to
capture food
particles
7. Grease retention
area, volume cap:
MGT500= 81.8L
3. Flow hits integral ramp MGT700= 149.1L
directing grease & entrained 5. Entrained air assists
air upwards upward flow of grease
6. Outlet baffle
prevent grease to
enter waste system
7
Solids Interceptor
92% Solids Capture
Code of Practice
SANS 10252/2
Features:
Easy to remove and maintain
removable screen filtration
Integrated lifting handles
Components/ parts available
Self maintainable
8
Why size a Grease trap?
Without a properly size flow control, the flow through the trap
may exceed the rating of the unit, causing lower efficiencies and
allowing grease to pass through the trap into the downstream
piping.
9
How to calculate the flow rate:
10
Typical Installations
Installed on the floor, semi recessed, fully recessed
Distance between
waste and Grease trap
not to exceed 7.6m
11
Cleaning and Maintenance
12
Marley advert – Plumbing Africa
Fact File
13