Sunteți pe pagina 1din 6

Thermo Scientific Pro-Line

Conveyor Protection Switches

Thermo Scientific™ Ramsey™ Thermo Scientific Ramsey conveyor


conveyor protection switches monitor protection switches are used
your conveyors, equipment, and for position information, control
processes. Using our conveyor signals, and to identify potentially
protection switches to prevent hazardous situations with your
accidents, protect equipment, and process equipment. When hazardous
reduce unscheduled shutdowns helps situations occur they activate alarms
to keep your profits and production at to stop your equipment. This keeps
their highest levels. your personnel safe and limits damage
to your equipment.
Features and Benefits
• Rugged, heavy-duty design These conveyor protection switches
• CSA approved for Class II, Div 1 & utilize a rugged heavy duty design.
2, Group E, F & G applications They are built to last, providing
• Accessories to suit your application many years of dependable service.
• Available with addressable modules The modular design of the base Improved ROS & SPS Versions
providing switch ID to PLC unit provides added convenience
• Improved temperature spec for for installation and maintenance.
low temp applications Numerous options allow you to pick
• Now available with 2 or 4 SPDT the right switch to fit your applications.
microswitches Use the conveyor protection switches
to protect your business in even the
most challenging applications.
Thermo Scientific Pro-Line
Conveyor Protection Switches

SPS-2E & SPS-4E TPS-2D ROS-2E & ROS-4E

Thermo Scientific Pro-Line Thermo Scientific Pro-Line Thermo Scientific Pro-Line


Safety Cable Pull Switch Tripper Position Switch Belt Misalignment Switch
This safety cable pull switch is used This tripper position switch is a heavy This belt misalignment switch is used
as an emergency shutdown device for duty limit switch. It is often used to to monitor the position and tracking of
conveyors or other equipment. They indicate the position of a tripper on a conveyor belts. It is mounted on the
meet OSHA and MSHA requirements conveyor with multiple discharge points. conveyor structure and adjusted so the
for safety shutdown devices. However, it can be used anywhere you roller arm is the proper distance and
need an extremely heavy duty limit angle from the outside edge of the belt.
Safety pull cables are attached to switch with physical activation. When a belt drifts out of alignment it
the actuating arm of the switch. contacts the roller actuator arm which
When force is applied to the pull The actuating arm of the tripper rotates the actuation shaft, causing the
cable it rotates the actuating arm and position switch uses a large Acetal belt misalignment switch to send an
actuating shaft. At a 20° rotation the contact roller, 3 in diameter by 1.75 in alarm signal.
switch enters a tripped and locked wide. When the roller makes contact it
position. The actuating shaft has rotates the actuation shaft which has The actuation shaft has two cams
two cams inside the housing. Each two cams inside the housing. Each cam inside the housing. Each cam actuates
cam simultaneously actuates an actuates an independent SPDT micro- an independent SPDT micro-switch for
independent SPDT micro-switch for switch for position or alarm signals. alarm signals. The first micro-switch
shutdown and alarm signals. actuates with a 10° rotation of the
The switch can be ordered with an actuation shaft for a warning alarm
The safety cable pull switch has one option where one of the SPDT switches signal, allowing operators to address
housing layout that may be used is actuated with clockwise rotation and the situation before it becomes a
interchangeably in mid-run or end-run the other SPDT switch is actuated with problem. The second micro-switch
positions of the safety pull cables. counter-clockwise rotation. This allows actuates with a 20° rotation of the
you to identify which direction the actuation shaft for a shut down alarm
Standard safety cable pull switches switch is activated from.
include a manual reset lever. This lever signal in order to prevent or minimize
equipment damage. The roller arm
keeps the switch locked in an alarm
has internal stainless steel bearings.
condition until it is manually reset by
This allows the switch to be used on
an operator.
conveyors with belt speeds up to
1250 feet per minute with outstanding
service life.
Nomenclature for ROS, SPS, & TPS

Nomenclature Examples
A B C D E F ROS-2E-1-4-NPT Belt Misalignment Switch, 2 SPDT microswitches,
cCSAus, NEMA-4, NPT conduit openings
PRODUCT IDENTIFIER

SWITCH VERSION NUMBER

HAZARDOUS AREA APPROVALS

FINISH / NEMA RATING

CONDUIT OPENINGS

OPTIONS
ROS-4E-1-4X-MET Belt Misalignment Switch, 4 SPDT microswitches, cCSAus,
NEMA 4X, MET conduit openings

SPS-2E-3-4X-NPT Safety Pull Switch, 2 SPDT microswitches, cCSAus haz


area, NEMA 4X, NPT conduit openings

TPS-2D-1-NP Tripper Position Switch, 2 SPDT microswitches, cCSAus,


nickel plated

F. OPTIONS (add all that apply)


LT Alarm Light (only available with 2D version of ROS & SPS)
RST Manual reset lever (Standard on SPS)
FLG Auxilliary flag alarm
SA Short roller arm for tight areas (ROS only)
MTBR Mounting bracket
CCW Independent signals for CW/CCW (TPS only)
ADD Addressable modules (only available with 2D version
of ROS & SPS)

E. Conduit Openings
NPT Standard 3/4-14 NPT threads
MET Metric M20x1.5 threads

D. FINISH / NEMA RATING


4 NEMA-4 Type enclosure, yellow finish, steel external components
4X NEMA-4X Type enclosure, yellow finish, stainless steel external
components
NP Nickel Plated Type NEMA-4X enclosure for extra
corrosion protection, stainless steel external components

C. HAZARDOUS AREA APPROVALS


1 cCSAus rated for non-hazardous area applications
3 cCSAus hazardous area rated for Class II, Div 1 & 2, Groups E,F, and G

B. SWITCH VERSION NUMBER


2E 2 SPDT microswitches ROS & SPS
4E 4 SPDT microswitches ROS & SPS
2D 2 SPDT microswitches TPS

A. PRODUCT IDENTIFIER
ROS Belt Misalignment Switch (Run off Switch)
SPS Safety Pull Switch
TPS Tripper Position Switch
Pro-Line Conveyor Protection Switches
Outputs Two or four SPDT microswitches rated for 10A 250 VAC , TPS only available
with 2 SPDT microswitches
Temperature ROS-2E/4E: -40° to +185° F (-40° to +85° C); SPS-2E/4E: -40° to +185° F (-40°
to +85° C); TPS-2D: -25°C to +80°C (-13°F to +176°F)
Enclosure Rating Type NEMA-4, NEMA-4X or Nickel Plated

Conduit Openings Two threaded 3⁄4-14 NPT or M20x1.5 metric threads

Actuating Arm Adjustments 22.5° increments from vertical

Agency Approvals cCSAus for ordinary locations or available with cCSAus approval for Class II,
Division 1 & 2, Groups E, F, & G
Actuating Force (ROS) 2.27 kg (5 lb)

Spacing (SPS) Recommended 30 m (100 ft) switch spacing and cable supports every 3 m (10 ft);
maximum spacing of 60 m (200 ft) on horizontal conveyors and 45 m (150 ft)
on inclined conveyors
Pull Force Rating (SPS) 3.63 kg (8 lb) to 8.16 kg (18 lb)

Dimensional diagrams for ROS, SPS, & TPS

Top View Front View Back View

191 mm
(7.50 in) Optional Manual Reset Lever
171 mm 21 mm
10 mm (6.75 in) (0.83 in) Mounting Spline A 4x Ø0.375 – 16 UNC
(0.37 in)

4x Ø10 mm 109 mm 44 mm
(Ø0.375 in) (4.30 in) (1.75 in)
100 mm 136 mm
(3.94 in) (5.34 in) 54 mm 13 mm
(2.13 in) (0.50 in)

13 mm 37 mm
(0.52 in) (1.47 in)
60 mm 114 mm
13 mm 17 mm (2.38 in) (4.50 in)
(0.52 in) (0.68 in)

Side View TPS Arm Dimensions SPS Arm Dimensions ROS Arm Dimensions

2x Ø0.75 – 14 NPT or 34 mm
25 mm 13 mm (1.34 in)
2x Ø20 mm x 1.5 41 mm (1 in) (0.5 in)
38 mm (1.63 in) 17 mm
(1.50 in) (0.69 in)

203 mm
25 mm (8 in)
(1.00 in)
89 mm
(3.50 in)
25 mm
(1.0 in) 102 mm
55 mm (4 in)
(2.18 in) 335 mm
13 mm (13.20 in)
(0.50 in)
Mounting Spline A 83 mm
(3.25 in)
Mounting Spline A

19 mm
(0.75 in)

Mounting Spline A 9 mm
(0.36 in)

Find out more at thermofisher.com/bulkweighing

© 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific
and its subsidiaries unless otherwise specified. PI.8114.0617
02-2472 Underspeed switch 9/5/02 3:21 PM Page 1

Ramsey Under Speed


Switch Model 60-23P

∆ Under Speed Switch in Rotating Equipment

Model 60-23P

Senses Under Speed Conditions in Rotating Equipment


The Ramsey Model 60-23P and prevents nuisance alarms. The second Operation
60-23PX Under Speed Switches provide delay accommodates an alarm to normal The Model 60-23P Under Speed Switch
a low-cost, dependable, versatile and condition after the under speed status monitors speed by sensing a ferrous
simple means of monitoring the rotational has been corrected. element attached to the rotating shaft
velocity of a shaft or other rotating or equipment. The detector generates
The under speed switch is housed in a
equipment. The Model 60-23P features impulses from the ferrous element and
gasketed weather-tight polyammide/
one-piece unitized construction. The closes alarm contact when the time
fiberglass enclosure (allowing exposure
electronics and output contacts are between impulses is greater than the
to harsh environments), or a cast
housed in the same unit with the detector. time adjusted by the setpoint. The unit
aluminum NEMA 9 enclosure for
Only two bolts are required to mount the operates on the number of impulses
explosion-proof applications.
unit. The non-contacting proximity-type received rather than actual revolutions.
detector has no moving parts. Once the The unit is ideally suited for a wide variety Low speed range may be enhanced by
simple installation is completed, the of industrial applications where the need increasing the number of ferrous
device is virtually maintenance-free. to monitor for under speed or slippage elements on the rotating shaft.
conditions exist. It may be used on
Two 10-second time delays add important
conveyor belts, bucket elevators and
benefits to the package. The first delay
other types of rotating equipment.

Weighing and Inspection


02-2472 Underspeed switch 9/5/02 3:21 PM Page 2

Features and Specifications


Features
• Non-contacting, proximity-type detector provides 60-23P Mounting Dimensions
longer life and lower operating costs.
• Two-bolt mounting assures simple installation. Ferrous iron
piece to be
detected
• Single-piece construction with no separate control unit.
Provides ease when setting up and/or troubleshooting. 04.41
1.38(35) 1.18(30) (112)
• Rugged housing is weather-tight, polyammide/fiberglass,
and sturdy, yet lightweight. .40(10)
2.68
• No moving parts and a longer trouble-free life. (68)

• Alarm/delay: 10 second delay while rotating equipment .35 (9)


Input Cables 1.10
(28)
1/2 -14 NPT
.20 (5)
reaches operating speed. .91 (23) .47 (12)
6.38
• Alarm to normal delay assures notification when (162)
speed drops below adjustable setpoint.

General Specifications
Voltage 110/220 VAC, +15% SET POINT
UNDER SPEED SWITCH

Frequency 47-62Hz INPUT ALARM

10% 100%

Consumption 5 Watts
5.47
(139)
Operating -4° F to +149° F (-20 C to +65 C) 1 2 3
NEU 110VAC 220VAC
4
NC
5
C
6
NO

Temperature Range POWER RELAY OUTPUT

Storage -40° F to +176° F (-40° C to +80° C)


Temperature Range
Alarm Contacts Two - one normally open, .55(14)
one normally closed.
Two amp, 250 VAC non-inductive load 2X 0.47
(012)
1.38(35)
Operating Range 60-600 impulses per minute 2.75(70)

Start-up Delay 10 seconds 3.86(98)

Alarm Setpoint Adjustable between 10% and


100% of operating speed
Maximum distance .35˝ (9 mm) 60-23PX Mounting Dimensions
from sensor to
ferrous element
Proximity Switch

Enclosure 60-23P - Polyammide/fiberglass, Ferrous iron piece


to be detected Input cable
gasketed weatherproof 3/4 - 14NPT
60-23X - Cast aluminum, NEMA 9 1.38(35)
explosion proof 1.18(30) 7.38
(187)

Weight 2.9 lb (1.3kg) Model 60-23P 4.00(102)


11.5 lb (5.2kg) Model 60-23PX .40(10)
2.25(57)
.23(6)
.06(2)
2.31
(59)
3.50(89)
7.13(181)

Dimensions shown in
inches and (millimeters)

501 90th Avenue N.W. • Minneapolis, MN 55433


Tel: (763) 783-2500 FAX: (763) 783-2525
http://www.thermoramsey.com
Catalog No. 20.550 (Rev. 6/02)
Printed in U.S.A. SP

S-ar putea să vă placă și