Documente Academic
Documente Profesional
Documente Cultură
9kW
1.6 to 4.7kW
Chilled Water Wall Mounted Units
Models HAW 007-009-018-022
Specifications
The H@Wair chilled water wall mounted units offer several advantages for Controls
air-conditioning applications in residential, hotel and small service sectors :
RC-08A IR remote control supplied with IR version.
Very compact line.
Presentation
H@Wair units operate in the following modes : Terminal block for connecting a wall thermostat (accessory).
2-pipe version.
Accessories
Reversible 2-pipe version.
Aqu@Net controller (mounted outside the unit).
And available in 4 sizes and 3 versions :
IR version without valve (IR SV) - Sizes 007 - 009 - 018 - 022.
Terminal block version without valve (TB SV) - Sizes 007 - 009 - 018 -
022.
All chilled water wall mounted units have been designed for easy maintenance
via removable front panel.
Casing
Made from a plastic structure with high mechanical properties and resistance
to aging.
Filter
Electrostatic and anti-bacterial synthetic type air filter accessible after opening
the front panel.
Ventilation
3-speed motor equipped with internal thermal protection, with high efficiency
tangential wheel ensuring quiet operation.
Operating limits
Power supply
Power supply : 230 V / 1 Phase / 50 Hz + Earth. Entering water temperature min. +5 °C
Entering water temperature max. +60 °C
Condensate drain pan Maximum operating hydraulic pressure 15 bars
Plastic with Ø 16 mm connection. Min. operating temperature
6 °C/15% HR
(room/return/around the unit)
Installation Max. operating temperature
40 °C/70% HR
(room/return/around the unit)
Drilling template provided.
1
Technical Data - HAW 2-pipe - With and without IR - Without valve
(1) According to Eurovent : Air = 27 °C dry bulb / 19 °C wet bulb - Water = 7 °C / 12 °C.
(2) According to Eurovent : Air = 20 °C, same flow as in cooling mode.
(3) Sound pressure levels considering a room having a volume of 100 m3, with a reverberation time of 0.5 seconds and a distance of 1 meter.
2
Technical Data - HAW 2-pipe - With IR - With valve
(1) According to Eurovent : Air = 27 °C dry bulb / 19 °C wet bulb - Water = 7 °C / 12 °C.
(2) According to Eurovent : Air = 20 °C, same flow as in cooling mode.
(3) Sound pressure levels considering a room having a volume of 100 m3, with a reverberation time of 0.5 seconds and a distance of 1 meter.
3
Cooling Capacities
4
Heating Capacities
60
With valve
50
40
30
20
10
9
∆P - kPa
8
7
6
5
Without valve
4
1
50 60 80 1000 2000 3000 4000 6000 8000 10000 20000
5
Dimensions and Weight - H@Wair 007 to 022
6
www.systemair.fr
Systemair Airwell SAS · route de Verneuil, 27570 Tillières-sur- Avre · Tél. 02 32 60 61 00 · Fax 02 32 32 55 13
september 2014
Systemair · EDM HAW-S-1GB/09.14
As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos.