Sunteți pe pagina 1din 346

 

Product Catalog 
 
Please use the PDF bookmarks and drop‐downs 
to the left for convenient selection and viewing of 
Hochiki America’s product line data sheets. 
 
7051 Village Drive, Suite 100 
Buena Park, CA 90621  
(714) 522‐2246 
sales@hochiki.com 
www.hochiki.com 
Table of Contents
A. Analog System F. Power Supplies

1  FireNET Plus® - Analog Addressable FACP 65  FN-300/400/600/1024-ULX Auxiliary Power Supply/Charger


2  FireNET® - Analog Addressable Fire Alarm Control Panel 66  FN-642/842/1042-ULADA - NAC Power Extenders
3  FireNET® 4127 - Analog Addressable Fire Alarm Control Panel w/Plexiglass 67  PE-6/10SN - Power Extenders
4  FN-LCD-N - LCD Network Annunciator
5  FN-LCD-S - LCD Serial Annunciator G. Voice Evacuation Systems
6  FireNET® Graphix Software Package
7  EMS Graphix Software 68  FNV-MP & FNV-DP Voice Evacuation System
8  FNP-LED - FireNET Plus® Graphix LED Display 69  FNV - VoiceNET Fire Phone Equipment
9  FN-DAC - Digital Alarm Communicator 70  EVAX 25 - Conventional Voice Evacuation System
10  DCP-AMS - Addressable Manual Pull Stations 71  EVAX 50 - Conventional Voice Evacuation System
11  FNP-1127-SLC - Single SLC Loop Expander 72  EVAX 100 - Conventional Voice Evacuation System
12  FN-4127-SLC - Dual SLC Loop Expander 73  EVAX 150 / 200 - Conventional Voice Evacuation System
13  FN-4127-IO - 16 Channel Input/Output Board
14  FN-4127-NIC - Network Interface Card H. Notification Appliances
15  FN-CTM - City Tie Module
16  FN-ACC-R/C Battery Enclosure 74  HE Series - Selectable Candela Evacuation Signals
17  Serial Cables - S187/X187/P187/V187 75  HC Series - Selectable Ceiling Mount Strobe and Horn Strobe
18  New York City Approval 76  HGOE-R / HGOE-W - Outdoor Enclosure
a) FN-2127-NY-R / FN-4127-NY-R - Analog Addressable Fire Alarm Control Panel 77  HBLP, HSB & HCSB Series - Back Box
b) FN-LCD-NYN - LCD Network Annunciator 78  HAVSM - Synchronization Control Module
c) FN-LCD-NYS - LCD Serial Annunciator 79  HSSPKCLP Series - Ceiling Mount Speaker/Strobe
80  HSSPKWLP Series - Wall Mount Speaker/Strobe
B. Analog Series 81  HX93 Series Mini Horn
82  WHE Series Weatherproof Evacuation Signals
19  ALN-V - Photoelectric Smoke Sensor 83  HEP Series - Colored Lens Expander Plate Strobe
20  ATJ-EA - Heat Sensor 84  HHLF Series - Low Frequency Audible Signal
21  ACC-V - Multi Criteria Sensor 85  B6-24 / B10-24 / BB-WP - Fire Alarm Bells & Weatherproof Back Box
22  Analog Sensor Bases
23  ASB - Analog Sounder Base I. FirePro® Xtinguish
24  ASBL - Analog Low Frequency Sounder Base
25  SCI-B4 / B6 - Short Circuit Isolator Analog Sensor Bases 86  FirePro® Xtinguish Series Aerosol Generators
26  DH-99A/AR - Analog Duct Detector 87  HCVR-3 - Conventional Releasing Panel
27  SOM-A/-AI - Class A Supervised Output Module 88  HCVR-AB - Ancillary Board
28  SOM-R - Supervised Output Module 89  HCVR-SDU - Status Display Unit
29  FRCME-P - Fast Response Contact Monitoring Module w/ Pigtails 90  HCVR-AS - Extinguishant Abort Switch
30  FRCME-M - Fast Response Contact Monitoring Module 91  HCVR-SQA - Sequential Activator
31  FRCMA/-I - Fast Response Contact Monitoring Module 92  HPS-DAK-SR - Manual Pull Station for Fire Suppression Release
32  SCI - Short Circuit Isolator 93  HCVR-DS - Disable Switch
33  R2M-L/LI/H/HI- Dual Relay Module 94  SOM-R-DS - Disable Switch
34  DIMM - Dual Input Monitoring Module
35  CZM - Conventional Zone Module J. FireNET Vapor®
36  RAI-LED - Remote Alarm Indicator
95  FireNET Vapor® VPR-1 Detector
C. Conventional System 96  FireNET Vapor® VPR-1P Detector
97  FireNET Vapor® VPR-4 & VPR-6 Detectors
37  HCA - Fire Alarm Control Panel 98  FireNET Vapor® VPR-15 Detector
38  HCP-1000 Series 99  FireNET Vapor® VPR-SD1 & SD2 Detectors
39  HRA-1000 Series 100  FireNET Vapor® - Accessories
40  HPS - Manual Pull Stations 101  FireNET Vapor® Design Services
41  HPS-SAH-WP -Weather Proof Single Action Manual Pull Station 102  OSID - Open-area Smoke Imaging Detection by Xtralis
42  HPS-DAK-WP - Weather Proof Dual Action Manual Pull Station
43  HPS-DAK-SR - Manual Pull Station for Suppression Release K. FireNET MarineTM
44  HPS-CP - Call Point Break Glass Station
45  HPS-SA-EX/WP - Explosion Proof Manual Pull Station 103  FireNET MarineTM FNM-2127 - Analog Addressable Fire Alarm Control Panel
104  FireNET MarineTM FNM-LCD-S - LCD Serial Annunciator
D. Conventional Series 105  FireNET MarineTM FNM-ALK-V - Photoelectric Smoke Sensor
106  FireNET MarineTM FNM-ACA-V - Analog Multi Criteria Sensor
46  SLR-24V - Photoelectric Smoke Detector 107  FireNET MarineTM FNM-NSA-4/6 - Analog Sensor Bases
47  SLR-24VN - Photoelectric / Heat Smoke Detector 108  FireNET MarineTM FNM-DIMM - Dual Input Monitoring Module
48  SLR-24H - Photoelectric / Heat Smoke Detector 109  FireNET MarineTM FNM-FRCME-M - Fast Response Contact Monitoring Module
49  SLR-835/SLR-835H - Photoelectric Smoke Detector 110  FireNET MarineTM FNM-FRCMA - Fast Response Contact Monitoring Module
50  SLR-835B - Direct-Wire Photoelectric Smoke Detector 111  FireNET MarineTM FNM-R2ML - Dual Relay Module
51  SLR-835BH - Direct-Wire Photoelectric Heat Smoke Detector 112  FireNET MarineTM FNM-AMS-KL-LP - Addressable Manual Pull Stations
52  SLV-24M - Photoelectric Smoke Detector Marine Approved
53  DCD-135/190 - Fixed Temperature / Rate of Rise Heat Detector L. Third Party Products
54  DFE-135/190 - Fixed Temperature Heat Detector
55  DSC-EA Rate of Rise Thermal Detector 113  12-24 SIR - Carbon Monoxide Detector by Quantum Group
56  SPC-24 - Projected Beam Smoke Detector 114  RFD-2000X - Ultraviolet & Infrared Flame Detector by Rezontech
57  HF-24 - Ultraviolet Flame Detector 115  Solo 200 - Universal Detector Removal Tool by SD i
58  DH-98 - Conventional Duct Detector 116  TH Series - Linear Heat Cables by Proline
59  DH-98 - Duct Detector Remote Accessories
60  Conventional Detector Bases M. Other

E. Testing Equipment 117  Technical Bulletin -- Maintenance - Analog


118  Technical Bulletin -- Maintenance - Analog 2
61  TSE-A100 - Self-Contained Smoke Generator 119  Technical Bulletin -- Maintenance - Conventional
62  NSRT/NSTT - Smoke Detector Tester/ Removal Tool 120  ISO Certificate
63  TRT-A100 - Smoke Detector Tester/ Removal Tool 121  UL Conventional Product Compatibility Listings
64  TCH-B100 - Analog Hand-Held Programmer 122  CSFM Listings
FireNET® Plus - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
STANDARD FEATURES

• Analog design using Hochiki’s advanced DCP protocol


for fast communication
• Up to 127 sensors & modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop
• Uses standard wire, no-shielded or twisted pair required on
SLC loops
• Integrated digital alarm communicator (DACT) with Contact
ID and SIA reporting formats
• Programmable sensitivity levels by device
• Alarm verification feature
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• 1 or 2 loop (option)
• RS-485 bus for panel network (option)
DESCRIPTION • Built-in RS-232 interface for programming via a PC
• 3 on board programmable Form C relays rated at 1 amp at
The FireNET® Plus 1127 series control panel is an analog 30VDC
addressable fire alarm panel with build options containing 1 or • 2 auxiliary power outputs, each rated 360mA at 24 VDC
2 SLC loops, a Digital Alarm Communicator/Transmitter • Loop Explorer Windows® configuration utility
(DACT), and an RS-485 bus for network communication. Each • Auto-learn feature
SLC loop supports 127 devices of any combination (sensors or • 500 network wide software zones
modules), and 127 analog sounder bases, for a possible total • Network capability of up to 64 panels (option)
of 254 points per loop. Communication between devices is • Built in help and alarm information screens
accomplished by use of standard cable (shielded or twisted • 2 on-board Class B (style Y) NAC circuits rated at 2.3 amps
pair is not required). Each panel includes a 4-amp power each (special application) and 1.6 amps each
supply and has 2 onboard NAC circuits. The RS-485 bus (regulated continuous)
provides communication to the panel network while another • Gentex, System Sensor, Wheelock, and Amseco NAC sync
RS-485 bus provides communication for peripheral devices. protocol built-in
The RS-232 interface allows the convenience of programming • Automatic day/night sensitivity modes
via a PC. • Fire Drill test function
• Walk test function
The system will support a variety of Hochiki devices such as • Powerful & versatile Cause & Effect wizard including:
photo, ion and heat sensors, which contain a unique, patented *Cause & Effect action
sensor design incorporating automatic drift compensation and *Disable function configuration
day/night sensitivity modes. Additional devices include contact *Test mode configuration
monitors, relay controllers, supervised auxiliary output and • Seismic certified
short circuit isolator modules. In addition, interfaces to
conventional detection systems can be established by using a
conventional zone-monitoring module.
PRODUCT LISTINGS
The Loop Explorer Windows® Software interface provides the
SIGNALING UL 864, Local Signaling Unit.
installer with fingertip access to installation programming and Types: Automatic, manual,
diagnostic tools. An Auto Learn feature offers the convenience waterflow, sprinkler supervisory,
Remote Station and Central 3038713
for quick start applications. Add to this Hochiki's reputation for Station Service (DACT)
high quality and dedicated service, and you have an Non-coded signaling.
S6468 NFPA 70, 72 &13 Compliant California State
exceptional product with performance and value. Fire Marshal
7165-0410:180
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com
F0087 03/2015
SPECIFICATIONS
Primary AC 120VAC @ 2.1 Amps 50/60hz or 220VAC @ 1.1Amps 50/60hz
Output DC 24VDC @ 5.25 Amps
Power Supply 4 Amp integrated
Charger Current 1.25 Amps max.
Dimensions 14.5" W x 19" H x 3.5" D
Weight 20 lbs. (without batteries)
Color Red (optional gray)
Material ABS/steel enclosure
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 panels max.)
Zones 500 network wide software zones per system
SLC loops 1 or 2 (class A, "style 6 or 7" or class B, "style 4")
Devices per loop 127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel 800 addresses+sub-addresses max. per panel
NAC Outputs (2) class B, 2.3 Amps (special application)
1.6 Amps Regulated (continuous)
Relay Outputs (3) Form C 1 Amp @ 30VDC
Aux. Power 2 outputs, 360mA @ 24VDC each
PC Port / Printer RS232
DACT Formats Contact ID and SIA

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES


MODEL DESCRIPTION
CONTROL PANEL EXPANDERS
FNP-1127-SLC SLC One Loop Expansion Card
FN-4127-NIC Network Interface Card
FN-4127-IO 16 Channel Input/Output Board
ANNUNCIATOR
FN-LCD-S Serial LCD Annunciator
FNP-LED Graphix Display
SLC LOOP DEVICES
ALG-V, ALK-V, ALN-V Analog Addressable Photoelectric Sensor
AIE-EA Analog Addressable Ionization Sensor
ATG-EA, ATJ-EA Analog Addressable Heat Sensor
ACA-V, ACC-V Multi-criteria Sensor
NSA-4 & NSA-6 Four Inch Sensor Base and Six Inch Sensor Base
SCI-B4 & SCI-B6 Four Inch Short Circuit Isolator Analog Sensor Base & Six Inch Circuit
Isolator Analog Sensor Base
ASB Analog Sounder Base
ASBL Analog Low Frequency Sounder Base
DH-98A, DH-98AR Analog Addressable Duct Detector Unit (DH-98AR and DH-99AR
DH-99A, DH-99AR have relays built-in)
MS-RA, MS-RA/R, MS-KA/R Remote Test Station for DH-98AR & DH-99AR
DCP-FRCME-M Contact Monitoring Module (mini w/terminal blocks)
DCP-FRCME-P Contact Monitoring Module (mini w/pigtail leads)
DCP-FRCME-4 Contact Monitoring Module (with faceplate/indicating LED)
DCP-FRCMA, DCP-FRCMA-I Class A Contact Monitoring Module (FRCMA-I has built-in SCI)
DCP-DIMM Dual Input Monitor Module (with faceplate/indicating LED)
DCP-CZM Conventional Zone Module
DCP-R2M Dual Relay Module
DCP-R2ML/H Series Dual Relay Module (R2ML-I & R2MH-I has built-in SCI)
DCP-SOM Supervised Output Module
DCP-SOM-A, DCP-SOM-AI Class A Supervised Output Module (SOM-AI has built-in SCI)
DCP-SOM-R Supervised Output Module for Releasing Pre-action System
DCP-SCI Short Circuit Isolator Module
DCP-AMS Series Addressable Manual Pull Station
ACCESSORIES
TCH-B100 Hand Held Programmer (portable device addresser)
FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries)
FNP-ETR Enclosure Trim Ring for panel flush mount
Hochiki America Corporation FireNETPlus ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FireNET® Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
STANDARD FEATURES

• UL 864 9th Edition Listed


• Seismic certified
• Analog design using Hochiki’s advanced DCP protocol for
fast and robust communication
• Up to 127 sensors & modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop
• Uses standard wire, no shielded or twisted pair required on
SLC loops
• Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
• 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps
each
• Programmable sensitivity levels per device & automatic day/
night sensitivity modes
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• 2 loop (FN-2127 Series) or 4 loop (FN-4127 Series) versions
DESCRIPTION (800 addresses/sub-addr. max.)
• Dual RS-485 bus for panel network
• 2 built-in RS-232 interfaces for programming via a PC and
The FireNET® 4127 control panel is an analog addressable
serial printer interface
fire alarm panel containing 2 or 4 SLC loops with each loop
• 5 on board programmable Form C relays rated at 1 amp at
supporting 127 devices of any combination (sensors or
30VDC (Fire1, Fire2, trouble, supervisory, aux.)
modules), and 127 analog sounder bases, for a possible total
• 500mA of auxiliary power available rated at 24 VDC
of 254 points. Communication between devices is transferred
• Loop Explorer Windows® configuration utility
through standard cable (shielded or twisted pair is not
• 500 network wide software zones
required). Each panel includes a 5.25 amp power supply and
• Network capability of up to 64 panels
has 4 on board NAC circuits. An RS-485 bus provides
• RS485 slave bus for expansion - up to 32 FN-4127-IO
communication to the panel network, while the RS-232
boards or up to 15 FN-LCD-S serial annunciators and up to
interface allows the convenience of programming via a PC.
17 FN-4127-IO boards
• Auto-learn feature
The system will support a variety of Hochiki devices such as
• Fire Drill test function
photo, ion and heat sensors, which contain a unique, patented
• Walk test function
sensor design incorporating automatic drift compensation and
• Alarm verification feature
day/night sensitivity mode. Additional devices include contact
• FireNET is UL listed for Central Station Service, Remote
monitors, relay controllers, supervised auxiliary output and
Station Service and Proprietary Service
short circuit isolator modules. In addition, interfaces to
• Operates on 120VAC or 240VAC input voltage
conventional detection systems can be established by using a
• Powerful & versatile Cause & Effect programming (up to 500
conventional zone-monitoring module.
maximum, network wide) including:
*Cause & Effect action
The Loop Explorer Windows® Software interface provides the
*Disable function configuration
installer with fingertip access to installation programming and
*Test mode configuration
diagnostic tools. An Auto-learn feature offers the convenience
for quick start applications. Add to this Hochiki's reputation for PRODUCT LISTINGS
high quality and dedicated service, and you have an SIGNALING UL 864, Local Signaling Unit.
exceptional product with performance and value. Types: Automatic, manual,
waterflow, sprinkler supervisory,
Remote Station and Central
Station Service (DACT)
Non-coded signaling.
California State
Fire Marshal
3033817
Specifications subject to change without notice. S8255 NFPA 70, 72 &13 Compliant 7165-0410:159

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com
F0068 03/2015
SPECIFICATIONS
Primary AC 120VAC @ 2.1 Amps 60hz or 220VAC @ 1.1Amps 50hz
Output DC 24VDC @ 5.25 Amps (4 Amps availble for system power)
Power Supply 5.25 Amps integrated
Charger Current 1.5 Amps max.
Dimensions 14.5" W x 24" H x 5" D
Weight 31 lbs. (without batteries)
Color Red (optional gray)
Material ABS/steel enclosure
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 panels max.)
Zones 500 network wide software zones per system
SLC loops 2 or 4 (class A, "style 6 or 7" or class B, "style 4")
Devices per loop 127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel (800 addresses+sub-addresses max. per panel)
NAC Outputs (4) 2.5 Amps @ 24VDC (class B)
Relay Outputs (5) Form C 1 Amp @ 30VDC
Voltage Outputs (3) 500mA @ 24VDC
Aux. Power 500mA @ 24VDC
Aux. Inputs (8) digital pull downs
PC Port / Printer RS232
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condsensing

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES


MODEL DESCRIPTION
CONTROL PANEL EXPANDERS
FN-4127-SLC Dual SLC Loop Expansion Card
FN-4127-NIC Network Interface Card
FN-4127-IO 16 Channel Input/Output Board
FN-DAC Digital Alarm Communicator
FN-CTM City-Tie Module (Local Energy Type)
ANNUNCIATOR
FN-LCD-N Network LCD Annunciator
FN-LCD-S Serial LCD Annunciator
SLC LOOP DEVICES
ALG-V, ALK-V, ALN-V Analog Addressable Photoelectric Sensor
AIE-EA Analog Addressable Ionization Sensor
ATG-EA, ATJ-EA Analog Addressable Heat Sensor
ACA-V, ACC-V Multi-criteria Sensor
NSA-4 & NSA-6 Four Inch Sensor Base and Six Inch Sensor Base
SCI-B4 & SCI-B6 Four Inch Short Circuit Isolator Analog Sensor Base & Six Inch Circuit
Isolator Analog Sensor Base
ASB Analog Sounder Base
ASBL Analog Low Frequency Sounder Base
DH-98A, DH-98AR Analog Addressable Duct Detector Unit (DH-98AR and DH-99AR
DH-99A, DH-99AR have relays built-in)
MS-RA, MS-RA/R, MS-KA/R Remote Test Station for DH-98AR & DH-99AR
DCP-FRCME-M Contact Monitoring Module (mini w/terminal blocks)
DCP-FRCME-P Contact Monitoring Module (mini w/pigtail leads)
DCP-FRCME-4 Contact Monitoring Module (with faceplate/indicating LED)
DCP-FRCMA, DCP-FRCMA-I Class A Contact Monitoring Module (FRCMA-I has built-in SCI)
DCP-DIMM Dual Input Monitor Module (with faceplate/indicating LED)
DCP-CZM Conventional Zone Module
DCP-R2M Dual Relay Module
DCP-R2ML/H Series Dual Relay Module (R2ML-I & R2MH-I has built-in SCI)
DCP-SOM Supervised Output Module
DCP-SOM-A, DCP-SOM-AI Class A Supervised Output Module (SOM-AI has built-in SCI)
DCP-SOM-R Supervised Output Module for Releasing Pre-action System
DCP-SCI Short Circuit Isolator Module
DCP-AMS Series Addressable Manual Pull Station
ACCESSORIES
TCH-B100 Hand Held Programmer (portable device addresser)
FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries)
FNP-ETR Enclosure Trim Ring for panel flush mount
Hochiki America Corporation FireNET ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FireNET™4127 - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
WITH PLEXIGLASS WINDOW
STANDARD FEATURES
• UL 864 9th edition Listed
• Seismic Certified
• Analog design using Hochiki’s advanced DCP
protocol for fast and robust communication
• Up to 127 sensors & modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop
• Uses standard wire, no shielded or twisted pair required on
SLC loops
• Supports Class B (style 4) and Class A (style 6 or 7) SLC
loops
• 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps
each
• Programmable sensitivity levels per device & automatic day/
night sensitivity modes
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• 2 or 4 loop versions (800 addresses/sub-addr. max.)
DESCRIPTION
• Dual RS-485 bus for panel network
This alternate build of the FireNET™ 4127 control panel • 2 built-in RS-232 interfaces for programming via a PC and
is equipped with a Plexiglass window to meet the serial printer interface
requirements of major cities including the City of • 5 on board programmable Form C relays rated at 1 amp at
Denver. Access level 2 is enabled as soon as the outer 30VDC (Fire1, Fire2, trouble, supervisory, aux.)
door of the enclosure is opened (CAT 30 Key). • 500mA of auxiliary power available rated at 24 VDC
The FireNET™ 4127 control panel is an analog addres- • Loop Explorer Windows® configuration utility
sable fire alarm panel containing 2 or 4 SLC loops with • 500 network wide software zones
each loop supporting 127 devices of any combination • Network Capability of up to 64 panels
(sensors or modules), and 127 analog sounder bases,
• RS485 slave bus for expansion - up to 32 FN-4127-IO
for a possible total of 254 points. Communication
boards or up to 15 FN-LCD-S serial annunciators and up to
between devices is transferred through standard cable 17 FN-4127-IO boards
(shielded or twisted pair is not required). Each panel
• Auto-learn feature
includes a 5.25 amp power supply and has 4 on board
NAC circuits. An RS-485 bus provides communication to • Fire Drill test function
the panel network, while the RS-232 interface allows the • Walk Test function
convenience of programming via a PC. The system will • Alarm Verification feature
support a variety of Hochiki devices: photo, ion and heat • FireNET is UL listed for Central Station Service, Remote
sensors, which contain a unique, patented sensor Station Service and Proprietary Service
design incorporating automatic drift compensation and • Operates on 120VAC or 240VAC input voltage
day/night sensitivity mode. Additional devices include
• Powerful & versatile Cause & Effect programming (up to 500
contact monitors, relay controllers, supervised auxiliary
maximum, network wide) including:
output and short circuit isolator modules. In addition,
*Cause & Effect action
interfaces to conventional detection systems can be *Disable function configuration
established by using a conventional zone-monitoring
*Test mode configuration
module. The Loop Explorer Windows® Software Continued on back.
interface provides the installer with fingertip access to
installation programming and diagnostic tools. An PRODUCT LISTINGS
UL 864, Local Signaling Unit.
Auto-learn feature offers the convenience for quick start Types: Automatic, manual, waterflow,
applications. Add to this a reputation for high quality and sprinkler supervisory, Auxiliary California
dedicated service makes this an exceptional product Service(local energy), and Central State Fire
Station Service, Remote Station Marshal
both in performance and value. Service and Proprietary Service
S8255 (DACT) Non-coded signaling.
7165-0410:159
Specifications subject to change without notice. NFPA 70, 72 &13 Compliant

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0093 12/2011
SPECIFICATIONS
Primary AC 120VAC @ 2.1 Amps 60hz or 220VAC @ 1.1Amps 60hz
Output DC 24VDC @ 5.25 Amps (4 Amps availble for system power)
Power Supply 5.25 Amps integrated
Charger Current 1.5 Amps max.
Dimensions 14.5" W x 24" H x 5" D
Weight 31 lbs. (without batteries)
Color Red (optional charcoal)
Material ABS/steel enclosure
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 panels max.)
Zones 500 network wide software zones per system
SLC loops 2 or 4 (class A, "style 6 or 7" or class B, "style 4")
Devices per loop 127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel (800 addresses+sub-addresses max. per panel)
NAC Outputs (4) 2.5 Amps @ 24VDC (class B)
Relay Outputs (5) Form C 1 Amp @ 30VDC FireNET ORDERING MODELS
Voltage Outputs (3) 500mA @ 24VDC
Aux. Power 500mA @ 24VDC
MODEL DESCRIPTION
Aux. Inputs (8) digital pull downs FN-2127-DDW FACP (2 Loop/5.25 Amps)
PC Port RS232 FN-2127-DDWN FACP (2 Loop/5.25 Amps) (w/Network)
Printer Port RS232 FN-4127-DDW FACP (4 Loop/5.25 Amps)
FN-4127-DDWN FACP (4 Loop/5.25 Amps) (w/Network)

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES


MODEL DESCRIPTION
CONTROL PANEL EXPANDERS
FN-4127-SLC Dual SLC Loop Expansion Card
FN-4127-NIC Network Interface Card
FN-4127-IO 16 Channel Input/Output Board
FN-DAC Digital Alarm Communicator
FN-CTM City-Tie Module (Local Energy Type)
ANNUNCIATORS
FN-LCD-N Network LCD Annunciator
FN-LCD-S Serial LCD Annunciator
SLC LOOP DEVICES
ALG-V Analog Addressable Photoelectric Sensor
ALK-V & ALK-V2 Analog Addressable Photoelectric Sensor
AIE-EA Analog Addressable Ionization Sensor
ATG-EA Analog Addressable Heat Sensor
NSA-6 Six inch Sensor Base
NSA-4 Four inch Sensor Base
ASB Analog Sounder Base
DH-98A Analog Addressable Duct Detector Unit
DH-98AR Analog Addressable Duct Detector Unit (with relays)
MS-RA, MS-RA/R,
MS-KA/R Remote Test Station for DH98A & DH98AR
FRCME-S Contact Monitoring Module (mini w/terminal blocks)
FRCME-P Contact Monitoring Module (mini w/pigtail leads)
FRCME-4 Contact Monitoring Module (with faceplate/indicating LED)
DIMM Dual Input Monitor Module (with faceplate/indicating LED)
CZM Conventional Zone Module
R2M Dual Relay Module
SOM Supervised Output Module
SOM-A, SOM-AI Class A Supervised Output Module With SCI or Without SCI
SCI Short Circuit Isolator Module
AMS Series Addressable Manual Pull Station
ACCESSORIES
TCH-B100 Hand Held Programmer (portable device addresser)
FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries)
FN-ETR Enclosure Trim Ring for Panel Flush Mount

Hochiki America Corporation FireNET ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FN-LCD-N - LCD NETWORK ANNUNCIATOR

STANDARD FEATURES
• UL 864 9th edition Listed
• 320 character liquid crystal display (8 line x 40
character)
• LED indicators for Fire, Supervisory Alarm, Pre-
Alarm, Fire Output Active, Power On, On Test, Panel
Sounder Silenced, Delay Active, More Events, Point
Bypassed, General Trouble, Power Trouble, System
Trouble & NAC Trouble
DESCRIPTION • Dual RS485 ports for primary fire network
• RS485 slave bus for expansion - up to 32 FN-4127-IO
The FN-LCD-N type LCD network annunciator is boards or up to 15 FN-LCD-S serial annunciators and
designed to be used with the FireNET analog up to17 FN-4127-IO boards
addressable system. It allows for remote access, • 2 built-in RS-232 interfaces for programming via a PC
monitoring & control of the FireNET system throughout and serial printer interface
the building. • 4 on board programmable Form C relays rated at 1
Amp at 30VDC (Fire, Supervisory, Trouble &
The FN-LCD-N is a true network annunciator that can
Auxiliary)
access, monitor & control any or all FireNET panels in
the network. Each FN-LCD-N is completely
• Same controls as the FireNET fire panel (Reset,
Panel Sounder Silence, Lamp Test, Alarm Silence,
independent. The highly intuitive user interface and Re-sound Alarm, Fire Drill, Programmable Function,
320 character LCD display of the FN-LCD-N is exactly More Events, More Fire Events, Enter & Exit)
the same as the FireNET panel. In addition to routing
• Local piezo sounder for event notification
any panel in the network to the FN-LCD-N, every event
category within each panel can also be individually
• Supports user codes & firefighter key to enable
access & controls
routed, as well as routing of all remote control functions
(reset, alarm silence, re-sound alarm) from individual
• Powered by FireNET Aux 24VDC or UL fire listed
Aux. 24VDC supply
panels. The FN-LCD-N supports the same RS485
expansion port as the FireNET panel, allowing for
• Available in red or charcoal, and can be surface or
flush mounted (using trim ring)
FireNET expansion boards and accessories to be
connected to the network annunciator.
• True network annunciator, any or all panels can be
routed to the FN-LCD-N. In addition, each event
The FN-LCD-N also has (4) output relays for fire, category can be individually routed to the FN-LCD-N
supervisory, trouble & auxiliary. The relays are
• Up to (64) FireNET panels & FN-LCD-N's can be
programmable (except supervisory).
networked together in any combination
Security is established by the use of a password or
• 500mA of auxiliary power available rated at 24VDC
firefighters enable key. Designed to be aesthetically
pleasing, the FN-LCD-N is available in charcoal grey
• Auto-learn feature
or red and can be surface or flush mounted using a • Built-in help & alarm information screens
standard trim ring kit. • Fire drill function
• Each FN-LCD-N is completely independent
PRODUCT LISTINGS • The FN-LCD-N can be configured to remote reset,
silence, resound, any or all panels on the network in
California any combination
UL 864, NFPA 70 & 72:
State Fire
Signaling Device
Marshal
S5694 7120-0410:165

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0071 10/2013
SPECIFICATIONS
Input DC 24VDC @ 270mA Max. ( + Aux. Power Load)
Aux. Output DC 24VDC @ 500mA
Dimensions 14.5" W x 10" H x 3.3" D
Weight 9.4 lbs
Color Red (optional charcoal)
Material ABS/steel enclosure
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condsensing
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 nodes max.)
Relay Outputs (4) Form C 1amp@30VDC
PC Port RS232
Printer Port RS232
Expansion Port RS485 (for optional expansion boards)

ENGINEERING SPECIFICATION

The contractor shall furnish and install where indicated on the plans, the network annunciator model FN-LCD-N.
The FN-LCD-N shall connect to the FireNET fire alarm control panel (FACP) network. The network annunciator
shall be capable of annunciating on its 320 character display and local buzzer, the condition of any FireNET FACP
or network annunciator on the network. Up to 64 FN-LCD-N network annunciators or FireNET FACP's may be
connected together on the network. The FN-LCD-N shall be UL listed, and have surface or flush mount capability.

WIRING DIAGRAM

Hochiki America Corporation FN-LCD-N Specifications subject to change without notice.


FN-LCD-S - SERIAL LCD ANNUNCIATOR
STANDARD FEATURES

• UL 864 9th edition Listed


• Large 320 character liquid crystal display (8 line
x 40 character) allows viewing of system status
• LED indicators for Fire, Supervisory Alarm, Pre-
Alarm, Fire Output Active, AC Power On, On
Test, Panel Sounder Silenced, Delay Active,
More Events, Point Bypassed, General Trouble,
Power Trouble, System Trouble & NAC Trouble
• Same controls as the FireNET fire panel (Reset,
DESCRIPTION Panel Sounder Silence, Lamp Test, Alarm
Silence, Re-sound Alarm, Fire Drill, Program-
mable Function, More Events, More Fire Events,
The FN-LCD-S serial annunciator provides a Enter & Exit)
convenient and cost effective remote annunciator • Up to 15 FN-LCD-S serial annunicators may be
solution. Up to 15 FN-LCD-S annunciators can be connected to a FireNET control panel or network
connected to the slave RS-485 port of the FireNET annunciator
control panel or network annunciator. The FN-LCD-S’s • Resides on the FireNET slave RS-485 line
large 320 character display and navigation buttons are
• Local piezo sounder for event notification
a complete mimic of the FireNET control panel
display. The use of a common interface allows the • Supports user codes & firefighter key to enable
access & controls
user to easily operate the FN-LCD-S as if he were
operating the FireNET control panel directly. • Powered by FireNET Aux 24VDC or UL fire listed
Aux. 24VDC supply
Security is established by the use of a password or • Available in red or charcoal, and can be surface
firefighters enable key. Designed to be aesthetically or flush mounted
pleasing, the FN-LCD-S is available in charcoal grey • Built-in help & alarm information screens
or red enclosures. The FN-LCD-S can be surface or • Fire drill function
flush mounted without the need for a trim ring.
SPECIFICATIONS
Current Draw
Standby: 20mA @ 24VDC
Alarm: 110mA @ 24VDC
Dimensions
FN-LCD-S 10.88" W x 8.00" H x 1.38" D
Back Box 10.38" W x 7.38" H x 1.25" D
PRODUCT LISTINGS Weight 3.5 lbs
UL 864, Local Color Red (optional charcoal)
Signaling. NFPA 70,
72 &13 Compliant Material ABS/steel enclosure
California 3033817
S5694 Operating Temp. 32°F (0°C) 120°F (49°C)
State Fire
Marshal Relative Humidity 85% RH Non-Condsensing
7120-0410:165 Display 8 line x 40 character LCD
(320 characters total)
Specifications subject to change without notice. Network RS485 port
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0070 10/2013
ENGINEERING SPECIFICATION

The contractor shall furnish and install where indicated on the plans, the serial remote annunciator model
FN-LCD-S. The FN-LCD-S shall connect to the FireNET fire alarm control panel (FACP) or network
annunciator (FN-LCD-N) RS485 slave bus. The serial remote annunciator shall annunciate on its 320
character display and local buzzer, the condition of its master FireNET FACP. Up to 15 FN-LCD-S serial
annunciators may be connected together on a single RS-485 FireNET slave bus. The FN-LCD-S shall be
UL listed and compatible with the Hochiki FireNET control panel, and have surface or flush mount
capability.

WIRING DIAGRAM

1522RO @

FIT JUMPER
ADDRESS COMM1 0V +24V COMM2 FOR END OF LINE
RESET W / DOG RESET COMM1 COMM2
+

+
l

ON K S

1 2 3 4 COMMS
ACTIVE

Reset
Not Used
Switch
Not Used

DIP Switch used to set


the FN-LCD-S address RS485 End-of-line jumper . Put
between 1 -15 jumper in place when FN-LCD-S
is the last device on the RS485
buss “I/O Comm”.

7. PR2

8. PR3
l +

COMMS
ADDITIONAL
I/O BOARDS
To next
( +)
AUX serial
24 VDC
l +

24X (- ) FN-LCD-
S or
other
NETWORK (+)
RS485
l +

IN RS-485
(- ) Buss
Device
NETWORK
l +

OUT

To AUX 24VDC of control


FireNET Control Panel panel (as shown) or to UL
(section) 864/1481 listed AUX
24VDC Power Supply

Hochiki America Corporation FN-LCD-S Specifications subject to change without notice.


FireNET GRAPHIX SOFTWARE PACKAGE

STANDARD FEATURES PRODUCT OVERVIEW


• Choice of text, graphic, and event list display • FireNET & FireNET Plus control panels can send
when event occurs data to, and be controlled by, the FireNET graphix
• Versatile event analysis system providing a single point of coordination for
all alarms.
• Total history archive
• The powerful 32 bit program features a standard
• Easy to program Windows® look and feel.
• Secure System • The system has a wide range of configurability
• Cost effective compared to other systems options, and can utilize maps, photographs,
audio or a combination of all if required.
• Simple to use • User profiles allow the system manager to control
• Unlimited map linking the access level of each individual user.
• Display and control for multiple panels • A comprehensive history logging and reporting
system allows analysis of events and trends to
• Event history can be viewed, filtered and exported
be identified to reduce unwanted alarms.
to text or HTML documents
• Easy to program and simple to use, FireNET
graphix provides a cost effective solution for fire
alarm management at many levels.

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0084 01/2014
SYSTEM REQUIREMENTS FEATURES

• CD ROM Drive • Ability to import Loop Explorer configuration file to


FireNET graphix file
• 1Ghz Pentium or equivalent processor
• Drag and drop from device tree to maps
• Windows XP
• Real time Graph of device analog values
• 256MB RAM memory (recommended 1GB)
• Connectivity of additional workstations over
• 10GB Hard Drive (20GB recommended if many network. (Number of additional workstations
maps are to be used) depends on license)
• 32MB or better graphics card • FireNET graphix systems available in the following
packages;
• Any sound card
1 to 4 node package (GUS1-4)
• Monitor must support 1024 x 768 graphics driver 5 to 8 node package (GUS5-8)
• Mouse 9 to 16 node package (GUS9-16)
17 to 32 node package (GUS17-32)
• Printer (optional)
33+ node package (GUS33+)
• One RS232 serial or USB port per network • System upgrade packages available, call for more
information.
HOW TO ORDER FireNET GRAPHIX • To add additional workstations, use one of the
following part numbers;
Each panel and network annunciator is considered a 1 workstation (GUSR2001)
"Node". Order the package that corresponds with the 2 ~ 4 workstations (GUSR2004)
number of Nodes in your system.
5 ~ 8 workstations (GUSR2008)
* Example;
5 FireNET Panels + 1 FireNET
Network Annunciator = 6 Nodes,
order GUS5-8.
* To add one workstation;
order GUS5-8 + GUSR2001

Hochiki America Corporation FireNET Graphix Software Package Specifications subject to change without notice.
EMS GRAPHIX
STANDARD FEATURES
 UL 864 Listed
 Compatible with FireNET® 2127/4127, FireNET® Plus, and
FireNET® Network Annunciator
 Real-time display of text, graphic, and event list (Fire, Su-
pervisory, Trouble)
 Color coded event list
DESCRIPTION  Unlimited amount of history storage
EMS Graphix is a PC software tool used to monitor real-time  Ability to send panel control commands (Panel Sounder
events from a standalone, multiple standalone or multiple net- Silence, Alarm Silence, Reset)
worked fire alarm control panels. This software tool offers a
means to monitor events (Alarm, Supervisory, Trouble, etc.),  Easy to program and simple graphical user interface (GUI)
provide action instructions, locate devices and provide a build-  Secure system
ing floor plan.
 Ability to import Autocad drawings
 Event history can be viewed, filtered and exported to text
or HTML document

SYSTEM REQUIREMENTS
 CD ROM drive
 Pentium 4 Processor or newer
 Windows XP Pro, Vista Business, Windows 7 Pro,
GRAPHICAL USER INTERFACE MAP VIEW Windows 8/8.1
 100MB RAM memory (recommended 1GB)
 1GB hard drive (20GB recommended if many maps are to
be used)
 32MB or better graphics card
 Any sound card
 Monitor must support 1024 x 768 graphics driver
 Mouse or other pointer device
 RS232 or RS485 connections (one for each control panel
or network interface port)
GRAPHICAL USER INTERFACE EVENT LIST  Moxa NPORT 5110 (serial to IP/TCP converter)
 Compatible with Comark 06-UL864-026 all-in-one
 PC for UL 864 Listed solution
PRODUCT LISTINGS

California State
Fire Marshal
7300-0410:0211
S5694

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0168 05/2015
EMS GRAPHIX
SYSTEM EXAMPLES

TCP/IP
Converters

TCP/IP
Converters

TCP/IP
Converters

Multiple Standalone Panels

TCP/IP
Converters

Multiple Networked Panels

Hochiki America Corporation EMS GRAPHIX Specifications subject to change without notice.
FNP-LED - GRAPHIX LED DISPLAY

STANDARD FEATURES

• Available in red and gray


• Available in 3 different size enclosures
• LED's comes in 3 different colors: red, green, or yellow
• FNP-LED can be easily upgraded onsite with minimal cost
and effort

SPECIFICATIONS
Operating Voltage 21- 30VDC
Maximum Current 360mA
Wire Size 12AWG to 22AWG
Communication Method RS485
Max. Wiring Distance 3900ft. (1200m)
DESCRIPTION
Avalible Dimensions AM2: 14.50"W x 12.25"H x 3.50"D
AM3: 14.50"W x 18.90"H x 4.25"D
The FNP-LED system uses flexible, optic light guides to
AM4: 14.50"W x 24.25"H x 4.25"D
illuminate areas on a floor plan, laid over a high resolution grid.
Color Red (optional gray)
This unique system dispenses completely with wiring and
Material ABS/Steel Enclosure
enables indicators to be moved, removed or added onsite
Max. LED's AM2: 40 LEDs
without the need for any wiring. All indicators can be configured
AM3: 72 LEDs
to operate upon any event type and at point, zone or group
AM4: 88 LEDs
level via the powerful and intuitive Loop Explorer configuartion
Operation Temperature 20°F (-6°C) to 120°F (49°C)
tool.
Cabinet Lock Type CAT 30 Key
The FNP-LED can be supplied with or without optional LED's
and controls. Optional LED's indicate Power On, Fire, Trouble
and Disablements and optional controls are for Alarm Silence,
PRODUCT LISTINGS
Buzzer Silence, Lamp Test, and Reset. Housed in an attractive,
SIGNALING
slimline enclosure to match FireNET Plus Fire Alarm Panels.
High quality, full color floor plans provide a clear and
geographical indication of event activation, which enables fast
identification of the Fire Alarm source. S5694 California State 3038713
Fire Marshal
7120-0410:181

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com
F0102 03/2015
CURRENT RATINGS
Standby Current
Red LED Driver Board Contains 8 LEDs = 13mA
Red LED Expansion Board Contains 16 LEDs = 13mA
Green LED Expansion Board Contains 16 LEDs = 13mA
Yellow LED Expansion Board Contains 16 LEDs = 13mA
Alarm Current
Red LED Driver Board Contains 8 LEDs = 45mA
Red LED Expansion Board Contains 16 LEDs = 45mA
Green LED Expansion Board Contains 16 LEDs = 45mA
Yellow LED Expansion Board Contains 16 LEDs = 45mA

Hochiki America Corporation FNP-LED Graphix Display Specifications subject to change without notice.
FN-DAC - DIGITAL ALARM COMMUNICATOR

STANDARD FEATURES

• Contact ID and SIA reporting formats


• UL 864 9th Edition listed
• Programmable from FireNET control panel or by
using Loop Explorer
•Zone or Address (Point) reporting
• Remote upload / download and diagnostic tools
• Backup and Duplicate reporting
• Programmable daily test report interval
• Quick installation in FireNET enclosure
DESCRIPTION

The FN-DAC Digital Alarm Communicator reports


Alarm, Trouble, Supervisory and other system events
SPECIFICATIONS
using PSTN telephone lines. Events are reported to
a compatible central station monitoring receiver. The Power Requirements 24VDC @ 20mA
communicator may be configured to report by zone or Operating Temperature 0-49 C @ 93% RH
by address (point). The FN-DAC is installed in the Dimensions 5.48" x 7.48"
FireNET enclosure, or may alternately be installed in FireNET Firmware Required 3.8 or higher
the FN-LCD-N network annunciator. The FN-DAC Loop Explorer Version Required 6.0 or higher
receives data and power from the FireNET panel, or
power may be provided by a UL listed 24 VDC
regulated power supply. Events from one or more
networked panels may be reported using just one
FN-DAC communicator.

The FN-DAC contains a built-in modem which


allows a remote user to connect to the panel(s)
to view current status, panel event history and
sensor analog values. Panel programming data
may also be copied or sent to one or more network PRODUCT LISTINGS
panels. UL 864, NFPA 72: California
Central Station, Remote State Fire
Station & Proprietary S8255 7165-0410:0159

Continued on back.
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0073 01/2015
ENGINEERING SPECIFICATION
The contractor shall furnish and install where indicated on the plans, the FN-DAC Digital Alarm Communicator. The
FN-DAC shall connect to the FireNET 4127 fire alarm control panel RS-232 port. The communicator shall be
programmable by using the front panel controls or by using Loop Explorer software. The FN-DAC shall allow the
use of a computer and modem to remotely access the FireNET network to perform remote diagnostics and system
configuration. The FN-DAC shall be programmable to report events by zone or by address, and shall be capable of
reporting using Contact ID or SIA format.

WIRING DIAGRAM

Telephone line
connections

24 VDC
Input Power

To J5 connector
on FireNET panel

Hochiki America Corporation FN-DAC Specifications subject to change without notice.


DCP-AMS SERIES ADDRESSABLE MANUAL PULL STATIONS
SPECIFICATIONS
Operating Voltage (SLC) 17~41 VDC
Average Current Consumption 550uA (Typical)
660uA (Alarm)
Ambient Temperature 32°F (0 °C) ~ 120°F (49°C)
Maximum Humidity 90% RH, non-condensing
Dimensions 3.4"W x 4.8"H x 2.0"D
Mounting Single gang or 4" square
electrical box

MODEL DESCRIPTION
DCP-AMS Single Action Hex Key Lock
DCP-AMS DCP-AMS-KL DCP-AMS-LP Dual Action Hex Key Lock
DCP-AMS-KL Single Action Key Lock
DCP-AMS-KL-LP Dual Action Key Lock

DESCRIPTION
The DCP-AMS are the Hochiki America series of
addressable manual pull stations that provide a fast and
practical means of manually initiating a fire alarm signal.
Both single action and dual action manual pull stations
are available. Resetting of the pull station requires either
a Cat 30 key or a 1/8" hex key (depending upon the
model used).

An alarm condition is actuated by pulling down on the


handle of the DCP-AMS and DCP-AMS-KL single action
models. On the dual action models DCP-AMS-LP and
DCP-AMS-LP DCP-AMS-KL-LP DCP-AMS-KL-LP the Lift and Pull cover must be lifted
before pulling down on the pull station handle. Once
STANDARD FEATURES the pull station is activated, the handle cannot be put
back into a normal standby condition without using the
• Addressable integrated design key operated reset feature.
• All metal construction
• Single and dual action models available The DCP-AMS series is electronically addressable and
• Extremely easy to operate includes a bi-colored status LED. The LED blinks green
indicating normal communication with the DCP
• Bi-colored status LED indicates Standby and
compatible SLC loop. When an alarm condition is
Alarm conditions
actuated by pulling the handle, the LED will latch Red
• Address is programmable in EEPROM to indicate the alarm condition.
• Address can be programmed when installed
• Key lock or hex key lock models available PRODUCT LISTINGS
• Enclosed switch with glass rod (included)
• Terminals accept up to 14AWG wire California State
• Surface mount back box available Fire Marshal
• ADA compliant (except LP models) 3033215 7150-0410:169
S6512
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0066 09/2012
ENGINEERING SPECIFICATIONS
Manual pull stations shall be Hochiki addressable AMS-series single or dual action models, DCP-AMS, DCP-AMS-
KL, DCP-AMS-LP, or DCP-AMS-KL-LP. Models shall be made of 14 AWG CRS and painted with Red enamel. The
words Fire Alarm shall be in a contrasting color and be embossed text 1/2" tall. The electronics shall be fully
integrated into the manual pull station requiring only connection to the SLC loop of the control panel. Programming of
the manual pull station address must be possible with the manual pull station fully installed.

Manual pull stations shall be Underwriters Laboratories Inc. Listed, CSFM Approved, and be installed within the limits
defined in the Americans With Disabilities Act.

WIRING DIAGRAMS
Hochiki America Corporation
OUT TO
NEXT DCP-AMS
MODULE Addressable Manual Pull Station
Ser. No.
SC- S+

S+ SC-
For Proper Installation, see HA-06-135 Rev 12/05
S6512

NON-CODED ALARM BOX


36CC

UL
Listed + S
Hochiki
DCP - SC
Compatible
Panel

TYPICAL WIRING DIAGRAM EXAMPLE, CONNECTED


TO A COMPATIBLE LISTED CONTROL PANEL

Class B (Style 4)
Hochiki America Corporation Hochiki America Corporation Hochiki America Corporation
DCP-AMS DCP-AMS DCP-AMS
Addressable Manual Pull Station Addressable Manual Pull Station Addressable Manual Pull Station
Ser. No. Ser. No. Ser. No.

S+ SC- S+ SC- S+ SC-


For Proper Installation, see HA-06-135 Rev 12/05 For Proper Installation, see HA-06-135 Rev 12/05 For Proper Installation, see HA-06-135 Rev 12/05

S6512 S6512 S6512


+ S NON-CODED ALARM BOX NON-CODED ALARM BOX NON-CODED ALARM BOX
UL 36CC 36CC 36CC

Listed
Hochiki
- SC
DCP
+ S
Compatible
Panel - SC
Class A Return (Style 6)

Class A (Style 7)
Hochiki America Corporation Hochiki America Corporation
DCP-AMS DCP-AMS
Addressable Manual Pull Station Addressable Manual Pull Station
Ser. No. Ser. No.

+ S
For Proper Installation, see HA-06-063 Rev 2/02

For Proper Installation, see HA-06-063 Rev 2/02

For Proper Installation, see HA-06-063 Rev 2/02

For Proper Installation, see HA-06-063 Rev 2/02


Hochiki America Corporation

Hochiki America Corporation

Hochiki America Corporation

Hochiki America Corporation

(IN) S (IN) S (IN) S (IN) S


SIGNALING DEVICE

SER. NO. XXXXXXXXX

SER. NO. XXXXXXXXX

SER. NO. XXXXXXXXX

SER. NO. XXXXXXXXX


ISSUE NO. AH-9774

SIGNALING DEVICE

SIGNALING DEVICE

SIGNALING DEVICE

-
ISSUE NO. AH-9774

ISSUE NO. AH-9774

ISSUE NO. AH-9774

SC
DCP-SCI

DCP-SCI

DCP-SCI

DCP-SCI

(IN) SC (IN) SC (IN) SC (IN) SC


LISTED

LISTED
LISTED

LISTED

S+ SC- S+ SC-
UL (OUT) S
For Proper Installation, see HA-06-135 Rev 12/05
S6512 (OUT) S (OUT) S
For Proper Installation, see HA-06-135 Rev 12/05
S6512 (OUT) S

Listed NON-CODED ALARM BOX


S5694

NON-CODED ALARM BOX


S5694

S5694
S5694

(OUT) SC 36CC (OUT) SC (OUT) SC 36CC (OUT) SC

Hochiki
DCP
Compatible
Panel - SC

+ S

Hochiki America Corporation DCP-AMS, DCP-AMS-LP, DCP-AMS-KL AND DCP-AMS-KL-LP Specifications subject to change without notice.
FNP-1127-SLC SINGLE SLC LOOP EXPANDER

SPECIFICATIONS
Operating Voltage 24 - 40VDC
Board Current 75mA (+ loop current)
Loop Current 400mA max.
System Capacity 1 FNP-1127-SLC per FireNET Plus
panel (FNP-1127E series only)
Devices per loop 127 sensors/modules +
127 analog sounder bases, 254 total
Loop Load 50 ohms, 1uF, 1mH max.
impedance
Size 5.34" L x 4.52" W

STANDARD FEATURES

• Adds one SLC loop to the FireNET Plus DESCRIPTION


(FNP-1127E series) control panel
• The SLC loop is capable of 127 sensors/ The model FNP-1127-SLC Single SLC Loop Expander is
modules, plus 127 analog sounder bases, a one loop expander board for the FireNET Plus FNP-
for a potential total of 254 addresses 1127E series control panel. The FNP-1127-SLC
• The FireNET Plus 1127E control panel increases the loop capacity of the panel from 1 loop to 2
supports one FNP-1127-SLC, for a total of loops, doubling the loop capacity from 254 analog
two SLC loops per panel addressable points to 508. The loop expander board
installs quickly, mounting to the back of the main control
• Supports Class A and B wiring methods per
board. The FNP-1127-SLC has the same functionality as
NFPA 72 Styles 4, 6, and 7 (Style 7 requires
the built-in SLC loop on the FireNET Plus panel and
isolators)
utilizes Hochiki's robust DCP loop protocol for highly
• Fully supervised & power limited SLC loop
reliable and fast alarm reporting. Shielded or twisted pair
• Supports Hochiki’s DCP (Digital wiring for the SLC loop is not required.
Communication Protocol)
• Same functionality as built-in loop of
FireNET Plus control panel
• Uses standard wire; shielded/twisted pair is
not required on SLC loops

PRODUCT LISTINGS
UL 864 Category
UOJZ CNN: California
Signal System Control State Fire
Unit Sub-Assembly Marshal
S6468 NFPA72 compliant 3038713
7165-0410:180

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0101 04/2010
FN-4127-SLC DUAL SLC LOOP EXPANDER

SPECIFICATIONS
Operating Voltage 24 - 40VDC
Board Current 100mA (+ loop current)
Loop Current 400mA max. each
System Capacity One expander per FireNET
control panel
Loops per 2 SLC (Class A or B)
expander
Devices per loop 127 sensors/modules +
127 analog sounder bases, 254 total
STANDARD FEATURES Loop Load 50 ohms, 1uF, 1mH max.
impedance
• Adds two SLC loops to a two loop FireNET Size 6.3" L x 4.5" W
control panel
• Each SLC loop is capable of 127 sensors/
modules, plus 127 analog sounder bases, DESCRIPTION
for a potential total of 254 addresses per
loop (127+127 per loop)
The model FN-4127-SLC Dual SLC Loop Expander is
• FN-4127-SLC can be added at the factory or
a two loop expander board that increases the
installed in the field
standard FireNET loop capacity from 2 to 4 loops.
• Supports Class A and B wiring methods per The FN-4127-SLC can be added at the factory or
NFPA72 Styles 4, 6, and 7 (with isolators) installed in the field, and mounts within the main
• Fully supervised & power limited SLC loops control board location as a piggy-back board. By
• Supports Hochiki’s DCP (Digital adding the FN-4127-SLC, the FireNET capacity is
Communication Protocol) loop protocol increased from 254+254 to 508+508 analog
• Same functionality as built-in SLC loops of addressable points within the overall 800 address/
FireNET control panel sub-address limit. The FN-4127-SLC has the same
• One SLC expander (maximum) may be functionality as the built-in SLC loops. The FN-4127-
added per FireNET control panel SLC utilizes Hochiki’s robust DCP loop protocol for
• Each SLC loop is completely independent highly reliable and fast alarm reporting without the
and autonomous need for shielded or twisted pair wiring for the SLC
loops.
• Uses standard wire, no shielded or twisted
pair required on SLC loops
PRODUCT LISTINGS

• UL 864 Listed - S8255


• FM Approved - 3033817
• CSFM Listed - 7165-0410:0159
• NYC Approved - COA# 6171
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0062 09/2014
FN-4127-IO 16 CHANNEL INPUT/OUTPUT BOARD
(RS-485 BUS DEVICE)
SPECIFICATIONS
Supply Voltage 24 VDC Nominal
Channels (16) total per I/O board (each
configurable as input or output)
I/O Comms Bus Up to (32) expansion boards
Quiescent Current 20mA
Current per input 3mA max.
Current per output 100mA max. (*within overall limits)
*Current per bank of 500mA max. (for banks 1-8 & 9-16)
8 outputs
*Current per I/O board 1A max.
STANDARD FEATURES Communications RS485 two wire
Max Distance from 4,000 ft. (depends on method &
• 16 channels of input/output points
panel wire size used for input power).
• 32 I/O boards per FireNET panel (512 channels of
Cable Capacity 12 AWG max.
input/output points)
Indicators (2) LED's for communication status
• Each channel configurable as input or output point
• Inputs are opto-isolated non-supervised pulldown Size 7.5" L x 2.4" W
type triggered by “dry” contact from input source
• Outputs are open collector transistor pulldown DESCRIPTION
type (100mA max each) that provide “wet” voltage
output The FireNET FN-4127-IO is a 16 channel Input/Output
board that provides powerful input/output expansion &
• Simple 4 wire connection to control panel (2 for
addition to the FireNET system allowing up to thirty two I/O
power, 2 for data)
boards to be connected to each FireNET panel within the
• All inputs/outputs can be assigned to global FireNET network. Every I/O board connected to any panel
functions, any event category, and used in network is available to the entire network, which allows for network
wide Cause & Effect logic wide input/output mapping. Typical uses include graphical
• Can be mounted locally within control panel LED map displays/annunciators, tabular LED zone display/
enclosure or remotely via FN-ACC accessory annunciators, input/output logic to & from the fire system
enclosure up to 4000ft from the panel for secondary use (I/O board points cannot be used for
• Each I/O board has a unique address 1-32 (set via primary fire initiation inputs or notification outputs) such as
DIP switch) on the I/O Comms Bus access control, burglar, CCTV, intercom, voice, or other 3rd
• Input/Outputs are for secondary use, not for party systems. Each channel can be configured to produce
primary fire initiation inputs or notification outputs a variety of input actions or respond to a variety of output
• Two LED’s are provided for communication status categories or logic. All channels can trigger, or react from,
network wide cause and effect logic depending on their
PRODUCT LISTINGS configuration. The flexibility of these boards is further
enhanced by the fact that each of the channels is
configurable as either an input or an output. Connection
can be achieved through a simple two wire RS485
communications protocol and two wire power input. I/O
• UL 864 Listed - S8255 boards can be mounted locally in the control panel or
• FM Approved - 3033817 distributed on a bus up to 4,000ft from the panel when
• CSFM Listed - 7165-0410:0159 using the FN-ACC accessory enclosure.
• NYC Approved - COA# 6171 Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0061 09/2014
FN-4127-NIC NETWORK INTERFACE CARD

SPECIFICATIONS
Supply Voltage 24 VDC Nominal
Quiescent Current Consumption 40mA
Cable Length 4,000ft Max.
Cable Type Belden 9271, Belden 9860
Protocol RS-485
Address Setting Dipswitch
Operating Temperature 32F~120F
Operating Humidity 90%RH

STANDARD FEATURES DESCRIPTION


 Allows for the expansion of up to 64 panels on a
FireNET system The FN-4127-NIC Network Interface Card allows for
the expansion of up to 64 nodes (combination of
 Enables information to be transmitted between
FACP’s or annuciators) on a single FireNET network
control panels
wide system. Using the Loop Explorer configuration
 Network protocol designed for tolerance to
software up to 64 nodes can be programmed to
interference and data corruption
respond to in a variety ways-independently or system
 Each card configured to a unique address
wide. The flexibility extends the comprehensive
through use of a dipswitch
cause and effect programming capability to the entire
 Transmission distance of up to 4,000 ft.
network allowing actions to be started from any point.
 Uses standard type Belden cable suitable for
The network communication protocol has been
RS-485 applications
designed to be extremely tolerant to interference and
 Simple 2-wire loop connection
data corruption. The simple 2 wire loop connection
 Flexible configuration options
makes for ease during installation.
 Network wide Cause & Effect logic
 Fully secure against short or open conditions
ENGINEERING SPECIFICATIONS

The FN-4127-NIC Network interface card shall be


PRODUCT LISTINGS compatible for use with a FireNET 4127 analog
addressable control panel. The NIC shall be
mounted on the inside of the FACP and is
connected used a standard RS-485 type 2 wire
connection. Up to a maximum of 64 network cards
• UL 864 Listed - S8255 can be installed per one complete networked
• FM Approved - 3033817 system. The network card shall be addressed by
• CSFM Listed - 7165-0410:0159 use of a dipswitch.
• NYC Approved - COA# 6171

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0063 03/2015
FN-CTM CITY TIE MODULE

SPECIFICATIONS
Operating Voltage 12 ~ 30 VDC
Average Current Consumption 0mA (Standby)
Alarm Current 1A for 0.5 seconds
Ambient Temperature 32°F (0 C) ~ 120°F (49C)
Maximum Humidity 90% RH, non-condensing
Dimensions 4.2"W X 4.7"H X 1.1"D
Weight Approximately 3.0 ounces
Mounting 4" square electrical box

DESCRIPTION

STANDARD FEATURES The FN-CTM City Tie Module is used to connect a


Fire Alarm Control Panel to a Local Energy type City
Tie Monitoring circuit. The FN-CTM City Tie Module
• Interfaces Fire Alarm Control Panels to a Local circuit provides the power necessary to trip the
Energy type City Tie monitoring circuit Master Box Trip Coil when the Fire Alarm Control
• Integrates Fire Alarm Control Panel EOL device Panel goes into alarm.
into module for supervision of interface wiring
• Wide operating voltage The City Tie Circuit is capable of providing 1A for 0.5
• Power limited operation seconds to operate the Master Box Trip Coil. The
• Transient protection wiring is supervised to the Master Box by placing the
Fire Alarm Control Panel EOL device on the terminals
• Terminals accept up to 14 AWG wire
of the FN-CTM City Tie Module.
• Mounts to a standard 4" electrical back box

PRODUCT LISTINGS
UL 864, NFPA 70 & 72: California
Signaling Device State Fire
S8255 Vol. 2 Marshal
7170-0410:170

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0064 07/2012
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, the Hochiki America FN-CTM City Tie Module.
The module terminal blocks shall be capable of accepting up to 14 AWG wire. The FN-CTM shall be configured
such that the Fire Alarm Control Panel’s EOL (end of line) device connects directly with the FN-CTM to ensure
supervision of the interface wiring. The module shall fit into a standard 4" electrical back box. The FN-CTM shall
be Underwriter’s Laboratories Listed for the intended purpose.

Rear view of FN-CTM City Tie Module

WIRING DIAGRAM

Note: When City Tie wiring leaves


the building, install 26 AWG wire
between the City Tie module and
the Trip Coil. A short length of 24
AWG wire must be used to
interface between the 26 AWG
and the City Tie Module terminal
block. Maximum coil resistance
and wire resistance must not
exceed 30 Ohms.
Ground Wire

24 AWG

26 AWG

Hochiki America Corporation


FN-CTM
City Tie Module
Local Energy SERIAL NO.XXXXX
City Tie
Trip Coil
+
-
City Tie
Hochiki FireNET
+ or

-
NAC Input Compatible UL Listed
E.O.L. DEVICE Fire Alarm Control Panel
EOL
NAC Circuit Connections shown in Alarm condition NAC Circuit
For Proper Installation
S8255 see HA-06-137 Rev 07/12

Signaling Devices Wiring Polarity Shown in


ISSUE NO. BF-8887 Alarm Condition.
U.L. LISTED
E.O.L. DEVICE
FOR FireNET
PART NUMBER
0400-03180
10K OHM 1/4W

All Wiring is Power Limited, Connect only to Power Limited Circuits.


For Use Only With Supervised Circuits.
Hochiki America Corporation FN-CTM City Tie Module Specifications subject to change without notice.
FN-ACC-R / -C - BATTERY ENCLOSURE

SPECIFICATIONS
Models FN-ACC-R / FN-ACC-C
Max. Battery Capacity 2 x 33Ah
Max. I/O Board Capacity 6 x FN-4127-IO
Dimension 17.80"W x 14.85"H x 5.77"D
Colors Red or Charcoal
Material ABS/steel enclosure

DESCRIPTION
The FN-ACC is designed to provide a method to properly
store backup batteries for the FireNET and FireNET Plus
panels. The enclosure can also be used to mount 16
Channel I/O Boards. The battery enclosure comes in
two colors Red (FN-ACC-R) & Charcoal (FN-ACC-C) and
comes with a keylock.

DIMENSION

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0116 04/2011
X187, S187 Programming Cable
FN-V187 VoiceNET Serial Interface Cable
FN-P187 Printer Interface Cable

X187 Programming Cable S187 Programming Cable

FN-V187 VoiceNET Serial Interface Cable FN-P187 Printer Interface Cable

APPLICATION SPECIFICATIONS
X187/S187:
X187 and S187 are used to program the FireNET family
of panels. Cable Type: FireNET Family Programming
Cable Length: 8.3 feet (2.5 meters)
FN-P187 Printer Interface cable is used to connect a
Left Connector: 10 Pin Serial (Female)
serial printer to the FireNET family of panels.
Right Connector: 9 Pin - DB9 (Female)
FN-V187 VoiceNET Serial Interface Cable is used to X187: Non-Jacketed Version
interconnect a FireNET Panel with a VoiceNET Master
Panel. S187: Jacketed Version

Continued on back

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 • Buena Park, CA 90621-2268
Phone: 714/522-2246 • Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F092 04/2012
SPECIFICATIONS SPECIFICATIONS
FN-V187: FN-P187:
Cable Type: VoiceNET Integration Cable Cable Type: FireNET/FireNET Plus Printer Cable
Cable Length: 8.3 feet (2.5 meters) Cable Length: 8.3 feet (2.5 meters)
Left Connector: 10 Pin Serial (Female) Left Connector: 10 Pin Serial (Female)
Right Connector: 2 Wire Pin (male) Right Connector: 25 Pin Serial (male)

WIRING DIAGRAMS:
PROGRAMMING INTERFACE:

FNV-MP INTERFACE: (REFER TO FIRENET MANUAL V 1.86 OR HIGHER)

PRINTER INTERFACE:

Hochiki America Corporation • Serial Cables Specifications subject to change without notice.
ENGINEERING SPECIFICATIONS, continued
The base shall permit direct interchange with the HOCHIKI America AIE-EA ionization type smoke sensor, ALG-V
Photoelectric type smoke sensor, and the ATG-EA heat sensor.

The sensitivity of the sensor shall be capable of being measured by the control panel.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.

BASES
The HOCHIKI America except for ASB both YBN-NSA-4 and the HSB-NSA-6 mounting bases are electronics free and are
a simple rugged design with screw terminals for wiring connections. A common mounting base allows sensor inter-
change and maintains loop continuity when sensors are removed. A simple anti-tamper head locking system is provided
which is enabled by removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using
a small diameter screw driver.

TYPICAL WIRING DIAGRAMS


U.L.
LISTED
COMPATIBILE (+)
CONTROL
PANEL

NOTE: Fire alarm control panel (-)


compatibility is required for DCP
products. U.L. (+)
State-of-the-art communications LISTED
POWER
LIMITED
*
protocol, DCP, allows system SUPPLY

* - OPTIONAL WIRING CONFIGURATIONS FOR REMOTE OUTPUT


components (DCP sensors AIE-EA,
ALK-V, ALK-V, ALK-V2 and ATG-EA, (+)

bases and modules), to be used U.L.


LISTED

concurrently in a system's signaling COMPATIBILE


CONTROL
PANEL
line circuit.
(-)
U.L.
LISTED
POWER
LIMITED
SUPPLY (+)

UL LISTED
COMPATIBLE NEXT DEVICE
8mA Max.
CONTROL
PANEL
NUMBER OF ASB BASES PERMITTED
LOOP OUT
# of Bases Maximum Auxiliary 24VDC Power
In Alarm Wire Resistance (Total Auxiliary
NEXT DEVICE Run Length)
(Aux.) (+) FIGURE A

TOP VIEW
8mA MAX. 127 1.4 ohms
OUTPUT

NOTE: Class A style 7 wire configuration requires the installation of short circuit isolators (SCI). 75 2.4 ohms
LOOP IN
DO NOT CONNECT FOR CLASS B (STYLE 4)
60 3.0 ohms
CONNECT FOR CLASS A (STYLE 6 OR 7)

50 3.6 ohms
30 6.1 ohms
HO HA

HO HA
C HIK-08

C HIK-08
I AM 7 B

I AM 7 B

M M
-06 AS

-06 AS
ER V.

ER V.
ICA B

ICA B
RE

RE
CO

CO
RP

RP
.

.
SC

SC

20 9.1 ohms
G

G
TP

TP
3

3
F

F
DE

DE
TP

TP
TS

TS
1

1
C

AUX POWER
TP

TP
S

S
2

15 12.2 ohms
S5

S5
6

6
S
BLK

BLK
BLK

BLK
RED

RED
C-0 03

C-0 03
RED

RED
21

21
2

RED RED RED 10 18.3 ohms


BLACK BLACK BLACK

FIGURE B

BOTTOM VIEW NOTE: SLC maximum wiring resistance is 50 ohms.


Hochiki America Corporation ALK-V Specifications subject to change without notice.
FN-2127-NY-R / FN-4127-NY-R
ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
STANDARD FEATURES
• UL 864 9th edition Listed
• New York City Approved
• Analog design using Hochiki’s advanced DCP
protocol for fast and robust communication
• Up to 127 sensors & modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop
• Uses standard wire, no shielded or twisted pair required on
SLC loops
• Supports Class B (style 4) and Class A (style 6 or 7) SLC
loops
• 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps
each
• Programmable sensitivity levels per device & automatic day/
night sensitivity modes
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• 2 or 4 loop versions (800 addresses/sub-addr. max.)
DESCRIPTION
• Dual RS-485 bus for panel network
This alternate build of the FireNET™ 4127 control panel
• 2 built-in RS-232 interfaces for programming via a PC and
is equipped with a plexiglass window to meet the
serial printer interface
requirements of major cities. Access level 2 is enabled
as soon as the outer door of the enclosure is opened • 5 on board programmable Form C relays rated at 1 amp at
30VDC (Fire1, Fire2, trouble, supervisory, aux.)
(FDNY 2642 Key).
• 500mA of auxiliary power available rated at 24 VDC
The FireNET™ 4127 control panel is an analog addres-
sable fire alarm panel containing 2 or 4 SLC loops with • Loop Explorer Windows® configuration utility
each loop supporting 127 devices of any combination • 500 network wide software zones
(sensors or modules), and 127 analog sounder bases, • Network Capability of up to 64 panels
for a possible total of 254 points. Communication • RS485 slave bus for expansion - up to 32 FN-4127-IO
between devices is transferred through standard cable boards or up to 15 FN-LCD-S serial annunciators and up to
(shielded or twisted pair is not required). Each panel 17 FN-4127-IO boards
includes a 5.25 amp power supply and has 4 on board • Auto-learn feature
NAC circuits. An RS-485 bus provides communication to • Fire Drill test function
the panel network, while the RS-232 interface allows the
• Walk Test function
convenience of programming via a PC. The system will
support a variety of Hochiki devices: photo, ion and heat • Alarm Verification feature
sensors, which contain a unique, patented sensor • FireNET is UL Listed for Central Station Service, Remote
design incorporating automatic drift compensation and Station Service and Proprietary Service
day/night sensitivity mode. Additional devices include • Operates on 120VAC or 240VAC input voltage
contact monitors, relay controllers, supervised auxiliary • Powerful & versatile Cause & Effect programming (up to 500
output and short circuit isolator modules. In addition, maximum, network wide) including:
interfaces to conventional detection systems can be *Cause & Effect action
established by using a conventional zone-monitoring *Disable function configuration
module. The Loop Explorer Windows® Software *Test mode configuration
interface provides the installer with fingertip access to Continued on back.
installation programming and diagnostic tools. Fast PRODUCT LISTINGS
system startup is ensured by means of the built-in auto- UL 864, Local Signaling Unit.
learn feature. And with Hochiki's reputation for high Types: Automatic, manual, waterflow,
quality and outstanding service and support, you can be sprinkler supervisory, Auxiliary
Service(local energy), and Central
sure that the FireNET system is an exceptional product Station Service, Remote Station
both in performance and value. Service and Proprietary Service
S8255 (DACT) Non-coded signaling.
COA# 6171
Specifications subject to change without notice. NFPA 70, 72 &13 Compliant

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0194 06/2014
SPECIFICATIONS
Primary AC 120VAC @ 2.1 Amps 60hz or 220VAC @ 1.1Amps 60hz
Output DC 24VDC @ 5.25 Amps (4 Amps availble for system power)
Power Supply 5.25 Amps integrated
Charger Current 1.5 Amps max.
Dimensions 14.5" W x 24" H x 5" D
Weight 31 lbs. (without batteries)
Color Red
Material ABS/steel enclosure
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 panels max.)
Zones 500 network wide software zones per system
SLC loops 2 or 4 (class A, "style 6 or 7" or class B, "style 4")
Devices per loop 127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel (800 addresses+sub-addresses max. per panel)
NAC Outputs (4) 2.5 Amps @ 24VDC (class B)
Relay Outputs (5) Form C 1 Amp @ 30VDC
Voltage Outputs (3) 500mA @ 24VDC
Aux. Power 500mA @ 24VDC
Aux. Inputs (8) digital pull downs
PC Port RS232
Printer Port RS232

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES


MODEL DESCRIPTION
CONTROL PANEL EXPANDERS
FN-4127-SLC Dual SLC Loop Expansion Card
FN-4127-NIC Network Interface Card
FN-4127-IO 16 Channel Input/Output Board
FN-DAC Digital Alarm Communicator
FN-CTM City-Tie Module (Local Energy Type)
ANNUNCIATORS
FN-LCD-NYN Network LCD Annunciator
FN-LCD-NYS Serial LCD Annunciator
SLC LOOP DEVICES
ALG-V Analog Addressable Photoelectric Sensor
ALK-V Analog Addressable Photoelectric Sensor
ATG-EA Analog Addressable Heat Sensor
ATJ-EA Analog Addressable Heat Sensor
NSA-6, SCI-B6 Six inch Sensor Base
NSA-4, SCI-B4 Four inch Sensor Base
ASB Analog Sounder Base
DH-98A / DH-99A Analog Addressable Duct Detector Unit
DH-98AR / DH-99AR Analog Addressable Duct Detector Unit (with relays)
MS-RA, MS-RA/R,
MS-KA/R Remote Test Station for DH98A & DH98AR
FRCME-S / FRCME-M Contact Monitoring Module (mini w/terminal blocks)
FRCME-P Contact Monitoring Module (mini w/pigtail leads)
FRCME-4 / FRCMA's Contact Monitoring Module (with faceplate/indicating LED)
DIMM Dual Input Monitor Module (with faceplate/indicating LED)
CZM Conventional Zone Module
R2M / R2ML's / R2MH's Dual Relay Module
SOM Supervised Output Module
SOM-A, SOM-AI Class A Supervised Output Module With SCI or Without SCI
SCI Short Circuit Isolator Module
AMS Series Addressable Manual Pull Station
ACCESSORIES
TCH-B100 Hand Held Programmer (portable device addresser)
FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries)
FN-ETR Enclosure Trim Ring for Panel Flush Mount

Hochiki America Corporation FireNET ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FN-LCD-NYN - LCD NETWORK ANNUNCIATOR

STANDARD FEATURES
• UL 864 9th edition Listed
• New York City Approved
• 320 character liquid crystal display (8 line x 40
character)
• LED indicators for Fire, Supervisory Alarm, Pre-
Alarm, Fire Output Active, Power On, On Test, Panel
Sounder Silenced, Delay Active, More Events, Point
Bypassed, General Trouble, Power Trouble, System
DESCRIPTION Trouble & NAC Trouble
• Dual RS485 ports for primary fire network
The FN-LCD-NYN type LCD network annunciator is • RS485 slave bus for expansion - up to 32 FN-4127-IO
designed to be used with the FireNET analog boards or up to 15 FN-LCD-S serial annunciators and
addressable system. It allows for remote access, up to17 FN-4127-IO boards
monitoring & control of the FireNET system throughout • 2 built-in RS-232 interfaces for programming via a PC
the building. and serial printer interface
The FN-LCD-NYN is a true network annunciator that • 4 on board programmable Form C relays rated at 1
can access, monitor & control any or all FireNET panels Amp at 30VDC (Fire, Supervisory, Trouble &
Auxiliary)
in the network. Each FN-LCD-NYN is completely
independent. The highly intuitive user interface and • Same controls as the FireNET fire panel (Panel
Sounder Silence, Lamp Test, Re-sound Alarm, Fire
320 character LCD display of the FN-LCD-NYN is
Drill, Programmable Function, More Events, More
exactly the same as the FireNET panel. In addition to Fire Events, Enter & Exit)
routing any panel in the network to the FN-LCD-NYN,
every event category within each panel can also be
• Local piezo sounder for event notification
individually routed, as well as routing of all remote • Supports user codes & firefighter key to enable
access & controls
control functions (reset, alarm silence, re-sound alarm)
from individual panels. The FN-LCD-NYN supports the • Powered by FireNET Aux 24VDC or UL fire listed
Aux. 24VDC supply
same RS485 expansion port as the FireNET panel,
allowing for FireNET expansion boards and accessories • Available in red and can be surface or flush mounted
(using trim ring)
to be connected to the network annunciator.
The FN-LCD-NYN also has (4) output relays for fire,
• True network annunciator, any or all panels can be
routed to the FN-LCD-N. In addition, each event
supervisory, trouble & auxiliary. The relays are
category can be individually routed to the FN-LCD-
programmable (except supervisory). NYN
Security is established by the use of a password or • Up to (64) FireNET panels & FN-LCD-NYN's can be
firefighter's enable key. Designed to be aesthetically networked together in any combination
pleasing, the FN-LCD-NYN is available in red and can
• 500mA of auxiliary power available rated at 24VDC
be surface or flush mounted using a standard trim ring
kit. • Auto-learn feature
• Built-in help & alarm information screens
PRODUCT LISTINGS • Fire drill function
• Each FN-LCD-NYN is completely independent
UL 864, NFPA 70 & 72:
Signaling Device
S5694 COA# 6171

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0195 06/2014
SPECIFICATIONS
Input DC 24VDC @ 270mA Max. ( + Aux. Power Load)
Aux. Output DC 24VDC @ 500mA
Dimensions 14.5" W x 10" H x 3.3" D
Weight 9.4 lbs
Color Red
Material ABS/steel enclosure
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condsensing
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 nodes max.)
Relay Outputs (4) Form C 1amp@30VDC
PC Port RS232
Printer Port RS232
Expansion Port RS485 (for optional expansion boards)

ENGINEERING SPECIFICATION

The contractor shall furnish and install the network annunciator model FN-LCD-NYN, where indicated on the plans.
The FN-LCD-NYN shall connect to the FireNET fire alarm control panel (FACP) network. The network annunciator
shall be capable of annunciating on its 320 character display and local buzzer, the condition of any FireNET FACP
or network annunciator on the network. Up to 64 FN-LCD-NYN network annunciators or FireNET FACP's may be
connected together on the network. The FN-LCD-NYN shall be UL listed, and have surface or flush mount
capability.
WIRING DIAGRAM

Hochiki America Corporation FN-LCD-NYN Specifications subject to change without notice.


FN-LCD-NYS - SERIAL LCD ANNUNCIATOR
STANDARD FEATURES
• UL 864 9th edition Listed
• New York City Approved
• Large 320 character liquid crystal display (8 line
x 40 character) allows viewing of system status
• LED indicators for Fire, Supervisory Alarm, Pre-
Alarm, Fire Output Active, AC Power On, On
Test, Panel Sounder Silenced, Delay Active,
More Events, Point Bypassed, General Trouble,
Power Trouble, System Trouble & NAC Trouble
• Same controls as the FireNET fire panel (Panel
Sounder Silence, Lamp Test, Re-sound Alarm,
Fire Drill, Programmable Function, More Events,
DESCRIPTION More Fire Events, Enter & Exit)
The FN-LCD-NYS serial annunciator provides a • Up to 15 FN-LCD-NYS serial annunicators may
convenient and cost effective remote annunciator be connected to a FireNET control panel or
solution. Up to 15 FN-LCD-NYS annunciators can be network annunciator
connected to the slave RS-485 port of the FireNET • Resides on the FireNET slave RS-485 line
control panel or network annunciator. The FN-LCD- • Local piezo sounder for event notification
NYS’s large 320 character display and navigation
buttons are a complete mimic of the FireNET control
• Supports user codes & firefighter key to enable
access & controls
panel display. The use of a common interface allows
the user to easily operate the FN-LCD-NYS as if he • Powered by FireNET Aux 24VDC or UL fire listed
Aux. 24VDC supply
were operating the FireNET control panel directly.
• Available in red and can be surface or flush
Security is established by the use of a password or mounted
firefighter's enable key. Designed to be aesthetically • Built-in help & alarm information screens
pleasing, the FN-LCD-NYS is available in red • Fire drill function
enclosures. The FN-LCD-NYS can be surface or flush
mounted without the need for a trim ring.
SPECIFICATIONS
Current Draw
Standby: 20mA @ 24VDC
Alarm: 110mA @ 24VDC
Dimensions
FN-LCD-S 10.88" W x 8.00" H x 1.38" D
Back Box 10.38" W x 7.38" H x 1.25" D
Weight 3.5 lbs
Color Red
PRODUCT LISTINGS
Material ABS/steel enclosure
UL 864, NFPA 70 & 72: Operating Temp. 32°F (0°C) 120°F (49°C)
Signaling Device Relative Humidity 85% RH Non-Condsensing
S5694 COA# 6171
Display 8 line x 40 character LCD
(320 characters total)
Specifications subject to change without notice. Network RS485 port
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0196 06/2014
ENGINEERING SPECIFICATION

The contractor shall furnish and install the serial remote annunciator model FN-LCD-NYS, where indicated
on the plans. The FN-LCD-S shall connect to the FireNET fire alarm control panel (FACP) or network
annunciator (FN-LCD-NYN) RS485 slave bus. The serial remote annunciator shall annunciate on its 320
character display and local buzzer, the condition of its master FireNET FACP. Up to 15 FN-LCD-NYS
serial annunciators may be connected together on a single RS-485 FireNET slave bus. The FN-LCD-NYS
shall be UL listed and compatible with the Hochiki FireNET control panel, and have surface or flush mount
capability.

WIRING DIAGRAM

1522RO @

FIT JUMPER
ADDRESS COMM1 0V +24V COMM2 FOR END OF LINE
RESET W / DOG RESET COMM1 COMM2
+

+
l

ON K S

1 2 3 4 COMMS
ACTIVE

Reset
Not Used
Switch
Not Used

DIP Switch used to set


the FN-LCD-NYS RS485 End-of-line jumper . Put
address between 1 -15 jumper in place when FN-LCD-
NYS is the last device on the
RS485 buss “I/O Comm”.

7. PR2

8. PR3
l +

COMMS
ADDITIONAL
I/ O BOARDS
To next
( +)
AUX serial
24 VDC
l +

24X (- ) FN-LCD-
NYS or
other
NETWORK (+)
RS485
l +

IN RS-485
(-) Buss
Device
NETWORK
l +

OUT

To AUX 24VDC of control


FireNET Control Panel panel (as shown) or to UL
(section) 864/1481 listed AUX
24VDC Power Supply

Hochiki America Corporation FN-LCD-NYS Specifications subject to change without notice.


ALN-V PHOTOELECTRIC SMOKE SENSOR
APPLICATIONS
The Hochiki ALN-V Photoelectric Smoke Sensor is particularly
suited to detecting optically dense smoke typical of fires
involving materials such as soft furnishings, plastic, foam or
other similar materials which tend to smolder and produce
large visible smoke particles. Hochiki's unique design allows
fast response to flaming fires as well as smoldering fires while
preventing false alarms.
OPERATION
The detection chamber consists of a light-emitting diode
STANDARD FEATURES (LED) and photodiode arrangement. The chamber is designed
 Low profile - only 2.00" high, including base such that light emitted by the LED cannot normally reach the
photo diode. In the event of fire, particles of smoke enter the
 Simple and reliable device addressing chamber and scatter the light. As the smoke level increases,
the scattering effect increases, causing more light to hit the
 Automatic compensation for sensor contamination photodiode. The chamber contains a unique baffle design
 Built-in fire test feature which allows smoke to enter the chamber while preventing
external light from affecting the photodiode. The photodiode
 Uses the noise-immune Digital Communication input level is sampled to sense smoke density.
Protocol (DCP), which utilizes interrupts for fast
response to fires When the smoke density exceeds a preset threshold the
sensor transmits an interrupt to the fire control panel indicat-
 Two built-in power/alarm LEDs ing a fire condition. The fire alarm control panel can adjust the
sensor threshold to compensate for contamination.
 Programmable non-polling LEDs
Up to 127 devices are permitted on each SLC loop. A sensor
 Non-directional smoke chamber address is set by a hand-held programming unit. The sensor
 Vandal resistant security locking feature mounts to an electronics-free base and incorporates a locking
mechanism for secure installation. The base provides mount-
 Removable smoke labyrinth for cleaning or ing slots, terminals for field wiring and a third contact for a
replacement remote indicator/LED. The sensor incorporates dual LEDs for
SPECIFICATIONS easy viewing of sensor status.
Operating Voltage 17-41 VDC SENSOR SPACING
Standby Current 450μA
Smoke sensor spacing shall be in compliance with NFPA 72.
Alarm Current 540μA For smooth ceilings and in the absence of specific perfor-
Transmission Method DCP - Digital Communication Protocol mance-based design criteria, the distance between smoke
Maximum Humidity 95% RH Non-Condensing sensors shall not exceed a nominal spacing of 30 ft. (9.1m) or
UL Temperature Range 32°F to 115°F all points on the ceiling shall have a sensor within a distance
(0° C to 47° C) equal to or less than 0.7 times the nominal 30 ft. (9.1m)
spacing. Sensors shall be located within a distance of one-half
Operating Temperature 14°F to 122°F
the nominal spacing, measured at right angles from all walls
Range (-10°C to 50°C) or partitions extending upward to within the top 15 percent of
Sensitivity Range 0.7-4.0%/FT@300FPM the ceiling height. For additional instructions see NFPA 72.
0.7-3.86%/FT@2000FPM
0.7-2.65%/FT@4000FPM
PRODUCT LISTINGS
Air Velocity Range 0-4000 fpm
Color & Case Material Bone - ABS Blend California State
Weight 3.4oz (5.1 oz. with 4” base) Fire Marshal
Bases YBN-NSA-4, HSB-NSA-6, 7272-0410:0204
ASB, SCI-B4, SCI-B6, ASBL S1383 3054858

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0185 09/2015
ALN-V PHOTOELECTRIC SMOKE SENSOR

ENGINEERING SPECIFICATIONS
The contractor shall furnish and install Hochiki’s ALN-V (Photoelectric Sensor) as indicated on the plans. The combination sensor
head and twist lock base is UL Listed and it’s compatible with an UL Listed fire alarm control panel.
The base permits direct interchange with the Hochiki AIE-EA ionization type smoke sensor, ALG-V, ALK-V/ALK-V2 photoelectric
type smoke sensors, ATG-EA, ATJ-EA heat sensors and the ACA-V, ACC-V multi-criteria sensors.
The sensitivity of the sensor is capable of being measured by the control panel.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature is
optional and can be implemented when required.

BASES
The Hochiki HSB-NSA-6 and the YBN-NSA-4 mounting bases are electronics free and are a simple rugged design with screw
terminals for wiring connections. A common mounting base allows sensor interchange and maintains loop continuity when
sensors are removed. A simple anti-tamper head locking system is provided which is enabled by removing a small plastic tab on
the back of the sensor. Once locked, the head can be removed using a small diameter screwdriver.

HSB-NSA-6 Base YBN-NSA-4 Base


TYPICAL WIRING DIAGRAMS
HSB-NSA-6
UL LISTED
COMPATIBLE
CONTROL
PANEL

UL LISTED
POWER
LIMITED
SUPPLY
* HSB-NSA-6
8mA MAX. 8mA MAX.
OUTPUT OUTPUT
*-OPTIONAL WIRING CONFIGURATION FOR REMOTE OUTPUT

UL LISTED
COMPATIBLE
CONTROL
PANEL
8mA MAX.
OUTPUT

UL LISTED
POWER YBN-NSA-4
LIMITED
SUPPLY * 8mA MAX.
OUTPUT

NOTE: Fire alarm control panel compatibility is required for DCP products. DCP communications protocol allows system
components (DCP sensors AIE-EA, ALG-V, ACA-V, ACC-V, ALK-V, ALN-V, ATJEA and ATG-EA, bases and modules)
to be used concurrently on a system's SLC (Signaling Line Circuit).

Hochiki America Corporation ALN-V Photoelectric Smoke Sensor Specifications subject to change without notice.
ATJ-EA FIXED TEMP/RATE OF RISE HEAT SENSOR
APPLICATION
The Hochiki ATJ-EA Fixed Temperature / Rate of Rise
sensors provide accurate temperature measurement
data to the fire alarm control panel. These sensors are
well-suited for environments where dust, cooking fumes
or other factors make the use of smoke sensors
impractical.
OPERATION
STANDARD FEATURES The ATJ-EA incorporates a highly linear thermistor
circuit. The specially designed cover protects the ther-
 Low profile - only 2.00" high, including base mistor while allowing maximum air flow. The thermistor
 Simple and reliable device addressing method circuit produces a voltage proportional to the tempera-
ture. This information is transmitted to the control panel
 Uses the noise immune Digital Communication as a digital value. When the ambient temperature
Protocol (DCP), which utilizes interrupts for fast exceeds a pre-programmed threshold (fixed temp or
response to fires rate of rise), the sensor transmits an interrupt to the
 Rate of rise temperature threshold = 15°F/Min control panel indicating a fire alarm. The fire alarm
(determined by panel) control panel can adjust the sensor's fixed temperature
threshold for different installation requirements.
 Adjustable threshold temperature = 135°F - 190°F
(determined by panel) Up to 127 devices may be installed on each SLC loop.
The sensor address may be set by a hand-held
 UL maximum spacing of 70 feet programming unit. The sensor mounts to an electronics
-free base and incorporates a locking mechanism for
security. The base provides mounting slots, terminals
for field wiring and a third terminal for a remote indica-
SPECIFICATIONS tor/LED. The sensor has dual LEDs for easy viewing of
Operating Voltage 17 - 41 VDC the sensor status.
Standby Current 350µA SENSOR SPACING
Alarm Current 500µA Heat sensor spacing shall be in compliance with NFPA
Transmission Method DCP - Digital Communication 72. The distance between heat sensors shall not
Protocol
exceed their listed spacing or all points on the ceiling
shall have a sensor within a distance equal to or less
Rate of Rise 15° F/Min. (8.3° C/Min.) than 0.7 times the listed spacing. Heat sensors shall be
UL Temperature Range 135° F to 190° F located within a distance of one-half the listed spacing,
(57.2° C to 87.8° C) measured at right angles from all walls or partitions
extending upward to within the top 15 percent of the
Operating Temperature Range 32° F to 190° F
ceiling height. For additional instructions see NFPA 72.
(0° C to 87.8° C)
UL Maximum Spacing 70 feet
Maximum Humidity 95% RH Non-Condensing PRODUCT LISTINGS
Color & Case Material Bone - ABS blend
California State
Weight 3.2oz (4.9oz. with 4” base)
Fire Marshal
Bases YBN-NSA-4, HSB-NSA-6, 7270-0410:0203
S1383 3054858
ASB, SCI-B4, SCI-B6, ASBL

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0187 09/2015
ATJ-EA FIXED TEMP/RATE OF RISE HEAT SENSOR
ENGINEERING SPECIFICATIONS
Heat sensors are installed in accordance with NFPA 72, the UL Listed spacing requirements and the rules and
regulations set forth by the local authorities having jurisdiction. The contractor shall furnish and install, where indicat-
ed on the plans, fixed temp / rate of rise automatic heat sensors.
The heat sensor head and twist lock base needs to be UL Listed compatible with a UL Listed fire alarm control panel.
The base permits direct interchange with the Hochiki AIE-EA ionization type smoke sensor, ALG-V, ALK-V/ALK-V2
photoelectric type smoke sensors, ATG-EA, ATJ-EA heat sensors and the ACA-V, ACC-V multi-criteria sensors.
The sensitivity of the sensor is capable of being measured by the control panel.
The vandal-resistant, security locking feature is used in those areas as indicated on the drawing. The locking feature
is optional and can be implemented when required.
BASES
The Hochiki HSB-NSA-6 and the YBN-NSA-4 mounting bases are electronic free and are a simple, rugged design
with screw terminals for wiring connections. A common mounting base allows sensor interchange and maintains loop
continuity when sensors are removed. A simple anti-tamper head locking system is provided which is enabled by
removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using a small
diameter screwdriver.

HSB-NSA-6 Base YBN-NSA-4 Base


TYPICAL WIRING DIAGRAMS
HSB-NSA-6
UL LISTED
COMPATIBLE
CONTROL
PANEL

UL LISTED
POWER
LIMITED
SUPPLY
*
8mA MAX. 8mA MAX.
OUTPUT
HSB-NSA-6 OUTPUT
*- OPTIONAL WIRING CONFIGURATIONS FOR REMOTE OUTPUT

UL LISTED
COMPATIBLE
CONTROL
PANEL

8mA MAX.
OUTPUT
UL LISTED
POWER YBN-NSA-4
LIMITED
SUPPLY * 8mA MAX.
OUTPUT

NOTE: Fire alarm control panel compatibility is required for DCP products. DCP communications protocol allows system
components (DCP sensors AIE-EA, ALG-V, ACA-V, ACC-V, ALK-V, ALN-V, ATJ-EA and ATG-EA, bases and modules)
to be used concurrently on a system's SLC (Signaling Line Circuit).

Hochiki America Corporation ATJ-EA Fixed Temperature / Rate of Rise Sensor Specifications subject to change without notice.
ACC-V ANALOG MULTI-CRITERIA SENSOR
APPLICATIONS
The Hochiki ACC-V Multi-Criteria Sensor is particularly suited for
detecting smoke produced by a wide range of combustibles found in
various applications. Temperature monitoring is achieved by a ther-
mistor placed for optimum sensitivity. Hochiki's unique design allows
fast response to flaming fires as well as smoldering fires while mini-
mizing false alarms.
OPERATION
The ACC-V chamber consists of a light-emitting diode (LED) and
photodiode arrangement. The chamber is designed such that light
emitted by the LED cannot normally reach the photodiode. In the
STANDARD FEATURES event of fire, particles of smoke enter the chamber and scatter the
light. As the smoke level increases, the scattering effect increases,
 Low profile - only 2.00” high, including base causing more light to hit the photodiode. The chamber contains a
unique design which allows smoke to enter the chamber while pre-
 Simple and reliable device addressing venting external light from affecting the photodiode. The photodiode
 Automatic compensation for sensor contamination input level is sampled to sense smoke density. When the smoke den-
sity exceeds a preset threshold the sensor transmits an interrupt to
 Built-in fire test feature the fire control panel indicating a fire condition. The fire alarm control
panel can adjust the sensor threshold to compensate for contamina-
 Uses the noise-immune Digital Communication tion.
Protocol (DCP), which utilizes interrupts for fast The ACC-V heat portion incorporates a highly linear thermistor circuit,
response to fires with two thermistors mounted externally. The specially designed cover
protects the thermistor while allowing maximum air flow. The thermis-
 Two built-in power/alarm LEDs tor circuit produces a voltage proportional to temperature which is
 Programmable non-polling LEDs scaled, and transmitted as a digitally encoded value to the control
panel. When the ambient temperature exceeds a preprogrammed
 Non-directional smoke chamber threshold (fixed temperature), the sensor transmits an interrupt to the
control panel indicating a fire alarm. The fire alarm control panel can
 Vandal resistant security locking feature adjust the sensor threshold for different standard's requirements.

 Removable smoke labyrinth for cleaning or Up to 127 devices are permitted on each SLC loop. A sensor address
replacement can be set by a hand-held programming unit. The sensor mounts to
an electronics-free base and incorporates a locking mechanism for
SPECIFICATIONS secure installation. The base provides mounting slots, terminals for
Operating Voltage 17-41 VDC field wiring and a third contact for a remote indicator/LED. The sensor
incorporates dual LEDs for easy viewing of sensor status.
Standby Current 450μA
Alarm Current 450μA SENSOR SPACING
Transmission Method DCP - Digital Communication Protocol Smoke sensor spacing shall be in compliance with NFPA 72. For
Maximum Humidity 95% RH Non-Condensing smooth ceilings and in the absence of specific performance-based
design criteria, the distance between smoke sensors shall not exceed
UL Temperature Range 135°F to 150°F a nominal spacing of 30 ft. (9.1m) or all points on the ceiling shall
(57° C to 65° C) have a sensor within a distance equal to or less than 0.7 times the
Operating Temperature 14°F to 122°F nominal 30 ft. (9.1m) spacing. Sensors shall be located within a dis-
tance of one-half the nominal spacing, measured at right angles from
Range (-10°C to 50°C) all walls or partitions extending upward to within the top 15 percent of
Sensitivity Range 0.7-4.0%/FT@300FPM the ceiling height. For additional instructions see NFPA 72.
0.7-3.86%/FT@2000FPM
0.7-2.65%/FT@4000FPM
PRODUCT LISTINGS
Air Velocity Range 0-4000 fpm
Color & Case Material Bone - ABS Blend California State
Weight 4.2oz (5.9 oz. with 4” base) Fire Marshal
Dimensions 3.9”D x 1.8”H 7272-0410:0204
Bases YBN-NSA-4, HSB-NSA-6, S1383 3054858
ASB, SCI-B4, SCI-B6, ASBL
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0186 09/2015
ACC-V ANALOG MULTI-CRITERIA SENSOR

ENGINEERING SPECIFICATIONS
The contractor shall furnish and install Hochiki's ACC-V (Multi-Criteria Sensor) as indicated on the plans. The multi-criteria sensor
head and twist lock base is UL Listed and it’s compatible with an UL Listed fire alarm control panel.
The base permits direct interchange with the Hochiki ALG-V, ALK-V/ALK-V2, ALN-V photoelectric type smoke sensors, AIE-EA
ionization type smoke sensor, ATG-EA, ATJ-EA heat sensors and the ACA-V, ACC-V multi-criteria sensor.
The sensitivity of the sensor is capable of being measured by the control panel.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature is
optional and can be implemented when required.

BASES
The Hochiki HSB-NSA-6 and the YBN-NSA-4 mounting bases are electronics free and are a simple rugged design with screw
terminals for wiring connections. A common mounting base allows sensor interchange and maintains loop continuity when
sensors are removed. A simple anti-tamper head locking system is provided which is enabled by removing a small plastic tab on
the back of the sensor. Once locked, the head can be removed using a small diameter screwdriver

HSB-NSA-6 Base YBN-NSA-4 Base


TYPICAL WIRING DIAGRAMS
HSB-NSA-6
UL LISTED
COMPATIBLE
CONTROL
PANEL

UL LISTED
POWER
LIMITED
SUPPLY
* HSB-NSA-6
8mA MAX. 8mA MAX.
OUTPUT OUTPUT
*-OPTIONAL WIRING CONFIGURATION FOR REMOTE OUTPUT

UL LISTED
COMPATIBLE
CONTROL
PANEL
8mA MAX.
OUTPUT

UL LISTED
POWER YBN-NSA-4
LIMITED
SUPPLY * 8mA MAX.
OUTPUT

NOTE: Fire alarm control panel compatibility is required for DCP products. DCP communications protocol allows system
components (DCP sensors AIE-EA, ALG-V, ACA-V, ACC-V, ALK-V, ALN-V, ATJEA and ATG-EA, bases and modules)
to be used concurrently on a system's SLC (Signaling Line Circuit).

Hochiki America Corporation ACC-V Multi-Criteria Sensor Specifications subject to change without notice.
ANALOG SENSOR BASES
SPECIFICATIONS
Security Feature Plastic Tamper-lock
Color Bone PC / ABS Blend
Dimensions HSB-NSA-6: 6 inches
YBN-NSA-4: 4 inches
Mounting Box HSB-NSA-6: 3” & 4” Octagon &
Square
YBN-NSA-4: 3” Octagon
Compatible Detectors ALG-V, ALK-V, ALK-D, AIE-EA,
ATG-EA, ATJ-EA, ALN-V,
ACA-V

YBN-NSA-4 APPLICATION

The HOCHIKI America YBN-NSA-4 and the HSB-NSA-


6 mounting bases are electronics free and contain a
simple rugged design with screw terminals for wiring
connections. A common mounting base allows sensor
interchange and maintains loop continuity when sen-
sors are removed. A simple anti-tamper head locking
system is provided which is enabled by removing a small
plastic tab on the back of the sensor. Once locked, the
head can only be removed using a small diameter screw
driver.

HSB-NSA-6 OPERATION
STANDARD FEATURES
The YBN-NSA-4 and HSB-NSA-6 are designed specifi-
• UL & ULC Listed cally for use with the Hochiki NS Analog models AIE-
• Designed for use with all NS analog sensors EA, ALG-V, ALK-V, ALK-D, ALN-V, ATG-EA, ATJ-EA and
• Available in 4 and 6 inch models ACA-V.
• Contains a security locking tab for tamper
protection The YBN-NSA-4 and HSB-NSA-6 common mounting
bases allows for complete compatibility for all of the
PRODUCT LISTINGS Hochiki NS Series Analog sensors. The bases are
lightweight and very thin, providing a low profile once
California installed. The solder-less screw terminals enable quick
State Fire and easy wiring connections.
Marshal
CS463 7300-0410:132
S1383

MEA
284-91-E Vol. IV
3022559
Continued on back.
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0013 10/2014
ENGINEERING SPECIFICATIONS

The base shall permit direct interchange with the HOCHIKI America AIE-EA Ionization type Smoke Sensor, ALG-V,
ALK-V Photoelectric Smoke Sensor, ALK-D Photoelectric Smoke Sensor for in-duct use, ATG-EA Heat Sensor, and
the ACA-V Multi-criteria Sensor.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.

TYPICAL WIRING DIAGRAMS

YBN-NSA-4
(+)

UL LISTED
COMPATIBLE
DCP LOOP
(-) 8mA MAX.
OUTPUT

UL LISTED (+)
POWER LIMITED
SUPPLY
8mA MAX.
OUTPUT

HSB-NSA-6
(+)
UL LISTED
COMPATIBLE
DCP LOOP
(-)

UL LISTED
POWER LIMITED
SUPPLY (+)

8mA MAX. 8mA MAX.


OUTPUT OUTPUT

- OPTIONAL WIRING CONFIGURATIONS FOR REMOTE OUTPUT

NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components (DCP sensors AIE-EA,
ALG-V, ALK-V, ALK-D, ALN-V, ACA-V, ATJ-EA and ATG-EA, bases and modules), to be used
concurrently in a system's signaling line circuit.
Hochiki America Corporation Analog Sensor Bases Specifications subject to change without notice.
ASB - ANALOG SOUNDER BASE

SPECIFICATIONS
Operating Voltage 17 ~ 41 VDC
SLC Current 110µA (Typical)
Consumption 110µA (Alarm)
Auxiliary Supply Voltage 16 ~ 31 VDC
Auxiliary Current 550µA (Typical)
Consumption 18mA (Alarm)
Sound Pressure Level 85dB
at 10ft.
Max. Quantity Per Loop 127
UL Ambient Installation 32°F (0°C) ~ 100°F (38°C)
Shown without sensor Shown with sensor Temperature Range
Operating Temperature 32°F (0°C) ~ 122°F (50°C)
Range
Dimensions (without 1.34”H x 5.94”D
STANDARD FEATURES sensor)
Weight 0.455 lb
Relative Humidity 93% RH Non-Condensing
• Programmable evacuation codes - Continuous,
Compatible Detectors ALG-V, ALK-V, AIE-EA, ATG-EA,
March, ANSI Temporal patterns ACA-V
• Base learns the sensor address and assumes an
upper range address (128-254)
• Up to 127 sensors and 127 ASBs can be used on
one SLC loop DESCRIPTION
• Can be alarmed or reset by zone or by individual
address
• ASB SLC loop wire resistance = 50 ohms Max. The ASB Analog Sounder Base is designed for use
(total SLC wire run length) with Hochiki analog sensors ALG-V, ALK-V, ACA-V,
• High sound pressure level (85dB SPL at 10 feet) AIE-EA, and ATG-EA. Each addressable base is to
be connected to a Hochiki America Corporation DCP
Signaling Line Circuit (SLC). The ASB provides an
audible alarm in the immediate vicinity. Typical
applications are hotels, apartments, and hospitals.

The ASB has a highly configurable programming


algorithm that allows the user to set up groups of
bases for synchronization of modulation tones. Each
device has 16 states that are programmed with the
PRODUCT LISTINGS
desired output pattern to be used (e.g., “Temporal” or
California “March”) for each state.
State Fire
Marshal
3036551
S1383 7300-0410:161

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0056 07/2010
WIRING DIAGRAM

FIRE ALARM
CONTROL NEXT DEVICE
8mA Max.
PANEL

LOOP OUT

NEXT DEVICE
(Aux.) (+) FIGURE A

TOP VIEW
8mA MAX.
OUTPUT

NOTE: Class A style 7 wire configuration requires the installation of short circuit isolators (SCI).

DO NOT CONNECT FOR CLASS B (STYLE 4)

LOOP IN
CONNECT FOR CLASS A (STYLE 6 OR 7)
HO H A-

HOC H A-
C HI 08

H IK08-0 AS
KI -067 AS B

I A 67 B
M M
AM RE

M ER R EV
ERI V.

IC A . B
CA B
C OR

CO
RP
P.

.
SC

SC
G

G
TP

TP
3

3
F

F
DE

DET
TP1

TP
TS

SC
C

1
AUX POWER
TP

TP
S

S
2

2
S5

S 56
6

S
BLK

BLK
BLK

BLK
RE D

RE
C-01 03

C-01 03
RE

RED
2

2
D

RED RED RED

BLACK BLACK BLACK

FIGURE B

BOTTOM VIEW

NUMBER OF BASES PERMITTED


# of Bases Maximum Auxiliary 24VDC Power Wire Resistance
In Alarm (Total Auxiliary Run Length)

127 1.4 ohm


75 2.4 ohm
60 3.0 ohm
50 3.6 ohm
30 6.1 ohm
20 9.1 ohm
15 12.2 ohm
10 18.3 ohm

NOTE: SLC maximum wiring resistance is 50 ohms.

Hochiki America Corporation ASB Specifications subject to change without notice.


ASBL - ANALOG LOW FREQUENCY SOUNDER BASE

SPECIFICATIONS
Operating Voltage 17 ~ 41 VDC
SLC Current 154uA (Normal)
Consumption 154uA (Alarm)
Auxiliary Supply Voltage 16 ~ 31 VDC
Auxiliary Current 2.8mA (Normal)
Consumption (Normal)
Auxiliary Current 72mA @ 33VDC
Consumption (Alarm) 95mA @ 24VDC
140mA @ 16VDC
Shown without sensor Shown with sensor Auxiliary Current 92mA @ 33VFWR
Consumption (Alarm) 149mA @ 24VFWR
FWR 203mA @ 16VFWR
STANDARD FEATURES Sound Pressure Level 85dB
at 10ft.
• UL268 and UL464 listed Max. Quantity Per Loop 127
• Programmable evacuation codes - Continuous, UL Ambient Installation 32°F (0°C) ~ 100°F (38°C)
March, ANSI Temporal patterns Temperature Range
• 520Hz low frequency alarm signal meets NFPA Operating Temperature 32°F (0°C) ~ 122°F (50°C)
requirements for sleeping areas Range
• Base learns the sensor address and assumes an Relative Humidity 93% RH Non-Condensing
upper range address (128-254) Base Diameter 6.6”
• Up to 127 sensors and 127 ASBLs can be used on Base Height 3.1”
one SLC loop Compatible Detectors ALG-V, ALK-V, ALN-V,
• Programmable activation by general alarm, by zone AIE-EA, ATG-EA, ATJ-EA,
and/or by individual address ACA-V, ACC-V

• High sound pressure level (85dB SPL at 10 feet)


DESCRIPTION
The ASBL Analog Low Frequency Sounder Base is
designed for use with Hochiki analog sensors. Each
addressable base is to be connected to a Hochiki
America Corporation DCP Signaling Line Circuit
(SLC). The ASBL provides an audible alarm in the
immediate vicinity. Typical applications are hotels,
apartments, and hospitals.

The ASBL meets NFPA 72 requirements for low


frequency alarms in sleeping areas. Studies have
PRODUCT LISTINGS shown that a low frequency alarm signal is the most
California
effective at waking people with mild to moderately-
State Fire severe hearing loss. The ASBL is designed for
Marshal installation in sleeping areas, such as bedrooms,
Pending hotel rooms, etc. Operation and supervision of the
S1383
7300-0410:0210 ASBL is fully managed by the compatible fire alarm
control unit.
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0193 12/2014
DESCRIPTION, continued
The ASBL has a highly configurable programming algorithm that allows the user to set up groups of bases for
synchronization of modulation tones. Each device has 16 states that are programmed with the desired output
pattern to be used (e.g., “Temporal” or “March”) for each state.

WIRING DIAGRAM

SIDE A REV D SIDE A REV D SIDE A REV D


J3 J3 J3

SENSOR

SENSOR

SENSOR
Hochiki America Corporation Hochiki America Corporation Hochiki America Corporation
ASBL ASBL ASBL
CONTROL J2
S1383
J2
S1383
J2
S1383

SPEAKER

SPEAKER

SPEAKER
PANEL

TB2 TB2 TB2


S/N 910300001 S/N 910300001 S/N 910300001
AUX -

AUX -

AUX -
AUX - AUX - AUX -
AUX +

AUX +

AUX +
AUX + AUX + AUX +
LOOP OUT
SC

SC

SC
DCP S- DCP S- DCP S-
S

S
DCP S+ DCP S+ DCP S+

LOOP IN

AUX

NOTE: Class X wire configuration requires the installation of short circuit isolation.
DO NOT CONNECT FOR CLASS B CONNECT FOR CLASS X

MOUNTING

Hochiki America Corporation ASBL Specifications subject to change without notice.


SHORT CIRCUIT ISOLATOR ANALOG SENSOR BASES

SPECIFICATIONS
Operating Voltage 17 - 41 VDC
Current Consumption Normal: 160uA
Active: 10mA
Security Feature Plastic Tamper-lock
Color & Material Bone PC / ABS Blend
Dimensions SCI-B6: 6 inches
SCI-B4: 4 inches
Compatible Detectors ALG-V, ALK-V, ALK-D, AIE-EA,
ATG-EA, ACA-V

APPLICATION

SCI-B6 & SCI-B4 The HOCHIKI America SCI-B4 and the SCI-B6 are short
circuit isolation mounting bases containing a simple rug-
ged design with screw terminals for wiring connections.
These common mounting bases allows sensor inter-
STANDARD FEATURES change and maintains loop continuity when sensors are
removed. A simple anti-tamper head locking system is
• UL Listed provided which is enabled by removing a small plastic
• Ability to detect short circuit conditions tab on the back of the sensor. Once locked, the head
• Designed for use with all DCP analog sensor. can only be removed using a small diameter screw-
• Available in 4 and 6 inch models driver.
• Built-in LED indication upon short circuit condition
• Contains a security locking tab for tamper OPERATION
protection

The SCI-B4 and SCI-B6 are designed specifically for use


with the Hochiki NS Analog models AIE-EA, ALG-V, ALK-
V, ALK-D, ATG-EA, and ACA-V.

The SCI-B4 and SCI-B6 common mounting bases allow


for complete compatibility for all of the Hochiki Analog
sensors. The solder-less screw terminals enable quick
and easy wiring connections.

PRODUCT LISTINGS
California
State Fire
Marshal
7300-0410:186
S1383
Continued on back.
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0079 12/2011
ENGINEERING SPECIFICATIONS

The base shall permit direct interchange with the HOCHIKI America AIE-EA Ionization type Smoke Sensor, ALG-V,
ALK-V Photoelectric Smoke Sensor, ALK-D Photoelectric Smoke Sensor for in-duct use, ATG-EA Heat Sensor, and
the ACA-V Multi-criteria Sensor.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.

TYPICAL WIRING DIAGRAM

SCI-B 4 - SLC w ired to top of base as shown

SC I- B 4: T E RM INA L CO NN EC T IO N 1, 2, 5 A ND 6 W IRIN G SH O W N
IS S UP E RV ISE D A ND INH ER E NT LY PO W ER LIM IT E D

W IR IN G D IA G RA M
FA CP P lea se refe r to U L liste d F ire A larm C o ntro l
P an e l ins tallation ins tru ction s for w iring - +
de tails.
+
LO OP
O UT -
G roup of various D C P S ensors
LOO P
+ and/or M odules w ith SC I
IN -
- +

S CI-B 6: T B 1 W IRING S HO W N IS S U PE RV ISE D


A ND INH ER EN T LY P O W ER LIM IT E D
SC
HO HA
CH -xx-

S
IK xx S C
I A x R I-
ME E B
RIC V. A
A

S 56
CO
RP
.

- +

G roup of various D C P S ensors


and/or M odules w ith SC I

- +

NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components (DCP sensors AIE-EA,
ALG-V, ALK-V, ALK-D, ACA-V and ATG-EA, bases and modules), to be used concurrently in a system's signaling line circuit.

Hochiki America Corporation Short Circuit Isolator Analog Sensor Bases Specifications subject to change without notice.
DH-99 ANALOG DUCT DETECTOR
STANDARD FEATURES
• Detects and limits the spread of smoke
throughout building HVAC ducts
• Compatible with building automation and fire
alarm systems
• Installs quickly and easily
• No screens or filters to clean
• Rugged gray steel back box with clear cover
• Accessories - Remote LED alarm
indication capability (DH-99-AR only)
• Meets UL 268A Requirements
APPLICATION
The HOCHIKI AMERICA DH-99 Analog duct smoke
detector provides early detection of smoke and
Duct housing with an ALK-D analog
photoelectric sensor.
products of combustion present in air moving through
HVAC ducts in Commercial, Industrial and Residential
applications. The DH-99 is designed to prevent the
SPECIFICATIONS recirculation of smoke in areas by the air handling
D uct Detector Model # DH-99-A DH-99-AR systems, fans and blowers. Complete systems may
be shut down in the event of smoke detection. The
Detector Head model ALK-D
HOCHIKI AMERICA DH-99-A and the DH-99-AR
Detector Head Type Analog Photoelectric operate on a DCP powered loop (24 VDC source
Communication
required for DH-99-AR)
DCP Powered Loop
DCP Powered Loop/ PRODUCT DESCRIPTION
Input Voltage DCP Powered Loop
24V DC The DH-99 is designed and built to meet all local
Standby Current 390μA 390μA requirements, as well as the NFPA regulations
Alarm Current 540μA 540μA regarding duct smoke detectors. The DH-99-AR is
provided with output terminals for remote accesso-
2 form C rated at
Alarm Contacts N/A 10A@250V AC ries such as a remote status indicators and reset
key switches or push buttons. Air sampling is
Sensitivity Test Method Control Panel
accomplished by two tubes which protrude into the
Power,Alarm, duct. An exhaust tube of one standard length (7.5")
Remote Indication Compatibility
N/A Horn/Piezo
(Refer to DH-98 Accessories)
Test is supplied in the installation kit with the smoke duct
unit. Once the duct width has been determined the
Air Velocity 300 to 4000 ft/min.
air intake sampling tubes must be ordered. Sam-
Ambient Temperature 32°F to 100°F (0°C to 38°C) pling tubes are supplied in three standard lengths
Humidity 10% to 85% Relative Humidity 2.5 ft., 5 ft. and 10 ft. and cut to size to fit the duct.
(non-condensing)
Housing Material 18 G.A. steel backbox, clear plastic cover PRODUCT LISTINGS
Finish Grey Paint
Dimensions 91/8"L x 71/4"W x 21/4"H California
State Fire
Maximum Net Weight 3lbs. Marshal
Sampling Tubes 2.5ft., 5ft. or 10ft. Pending
S1383 3240-0410:0155
Specifications subject to change without notice.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0141 03/2014
PRODUCT DESCRIPTION, continued
Mounting the duct smoke unit is accomplished by the use of a template and 4 sheet metal screws, which are
provided. Mounting can be achieved without the removal of the clear cover which is secured by 4 capture
screws.

The compact DH-99-AR contains 2 sets of form "C" contacts rated at 10 amps.

The pilot and alarm visual indicators, provided on the front of the DH-99-AR duct unit, signal the operating
status of the device. A manual test/ reset switch is located along side the visual indicators.

ENGINEERING SPECIFICATIONS
Air duct smoke detectors shall be HOCHIKI AMERICA DH-99 Series. The detectors shall be listed by Underwriters
Laboratories per UL 268A. The detectors shall operate at air velocities from 300 feet per minute to 4000 feet per
minute.

The duct detector housings shall be of metal construction and complete mechanical installation may be
performed without removal of the detector cover. The duct detector shall not require additional filters or screens
which must be maintained. The housing shall contain a base which will accept an analog photoelectric sensor
head. Terminal connections shall be of the screw type and be a minimum of #6 screw. For installations
requiring relay functions, terminals shall be provided for remote pilot, remote alarm indication, strobe/ horn and
remote key switch. For installation not requiring relay functions, visual indication of alarm and power must be
provided on detector front. A manual reset switch shall be located on the front of the device (DH-99-AR only).
All wiring must comply with local codes and regulations.

WIRING DIAGRAMS

DH-99-A ALK-D ANALOG Note ○ ○ ○ ○ ○ ○ ○ ○ ○ ○


SENSOR
1 2 3 4 The DH-99-A and DH-99-AR
are not self-contained
UL LISTED sensors. This product is
CONTROL PANEL
compatible only with fire
LOOP INTERFACE

S (+) alarm control panels that


utilize Hochiki's Digital
TO NEXT Communications Protocol,
SENSOR DCP. For example the
SC (-)
FireNET Control Panel.

FAN SHUT DOWN EXAMPLE

DH-99-AR OBSERVE POLARITY


FAN
SUPPLY VOLTAGE
INPUT VOLTAGE
24 V.D.C.
10 mA Standby
55mA Alarm

+ -
REMOTE
ADDRESSABLE ALARM
LOOP LED
+
1 2 3 4 5 6 7 8 9 10 11 12
- +
C C
REMOTE
NC NO NC NO
PILOT LED ALARM CONTACTS ALARM CONTACTS
10.0A @ 250VAC 10.0A @ 250VAC

UL LISTED REMOTE TEST


CONTROL PANEL SWITCH
(Test function only. does not reset.)
LOOP INTERFACE

S (+)
TO NEXT SENSOR
ANALOG ADDRESSABLE
OR RETURN
SC (-) FIELD LOOP WIRING
TO CONTROL PANEL
Terminate Remote Accessories as indicated above (if required).
This is not a self-contained stand alone detector.
A U.L. Listed Analog Addressable Fire System is required.

Hochiki America Corporation DH-99 ANALOG DUCT DETECTOR Specifications subject to change without notice.
DCP-SOM-A/-AI - CLASS A SUPERVISED OUTPUT MODULE

SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Auxiliary Supply Voltage 24 VDC
Average Current Consumption
SOM-AI - 420μA (Typical), SOM-A - 220μA (Typical)
(on S-SC Line) Maximum 6mA: Red Alarm LED On
Current Consumption on
Auxiliary Power Lines Typical 50μA
SCI On Resistance
40m ohm Max. (Normal Condition)
SCI Fault Detection Threshold 12 volts (Typical)
SCI Isolation Current
(Short Circuit Condition) 10mA (Typical)
Maximum Quantity Per Loop 127
STANDARD FEATURES Dimensions 4.2"W x 4.7"H x 1.4"D
Ambient Temperature 32°F (0°C) ~ 120°F (49° C)
• Built-in SCI circuitry (SOM-AI only)
• Flexible application Mounting 4" square electrical box
• Quick response to emergency conditions Maximum Output Current 2A@24VDC power limited
• Operation parameters are maintained by the Relative Humidity 90% RH Non-condensing
module, and individual communication with the
control system during emergency conditions
is not required DESCRIPTION
• Contacts are rated 2.0 Amps @ 24VDC The Class A Supervised Output Modules (DCP-SOM-A &
• Programming is highly flexible providing 16 SOM-AI) have been designed to provide application
priority states plus zoning capability flexibility and quick response to emergency conditions.
• Programmed device output is turned off, silenced, Flexibility is provided by a wide range of operating
or programmed to output the selected pattern modes, including supporting multi-zone operations, and/
• UL 864 Listed or functions, up to 16 different modulation patterns and
multi-state programming. The operating parameters for
the DCP-SOM-A & -AI are maintained by the module
and do not require individual communication with the
control system during emergency conditions to operate.
PRODUCT LISTINGS The control panel simply broadcasts system conditions
on the Signaling Line Circuit (SLC) and the DCP-SOM-A
California & -AI modules do the rest based upon the custom
State Fire configuration. Each DCP-SOM-A & -AI provides a single
Marshal 3036830 Class B or Class A circuit rated for 2.0 Amps @ 24
7300-0410:150 VDC. Each DCP-SOM-A & -AI also requires a 24 VDC
S5694
power source in addition to the SLC.

Specifications subject to change without notice.


Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0091 03/2014
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, addressable Class A Supervised Output Modules
(DCP-SOM-A & -AI). The modules shall be UL listed and compatible with the fire alarm control panel. The device
address shall be electrically programmable and stored in EEPROM. A bi-colored LED shall flash to indicate normal
system communication .
The DCP-SOM-A & -AI shall be supplied with a plastic cover and shall be suitable for mounting to a 4" square or
double gang electrical back box. The DCP-SOM-A & -AI shall provide a monitor LED that is visible from outside the
cover plate.

Back side of a SOM-AI Back side of a SOM-A


WIRING DIAGRAM OUT TO NEXT
U.L. LISTED 1481 24VDC INTERFACE MODULE
REGULATED, POWER
S+ SC-
LIMITED SUPPLY FOR FIRE
PROTECTION SIGNALING
SERVICE FOR AUDIBLE Hochiki America Corporation
DEVICES. REFER TO TB1 DCP-SOM-A HOCHIKI
CLASS A SUPERVISED OUTPUT MODULE
CONTROL PANEL 24V +
MANUFACTURER'S 24V+ SER. NO. 910300001

INSTALLATION 24V - U.L. LISTED


24V- IN S+ S+
INSTRUCTIONS. COMPATIBLE
FIRE CONTROL
OUT+ IN SC- SC-
PANEL
OUT- For Dry Indoor Use Only

IN+
For Proper Installation CIRCUIT OUT+, OUT-, IN+, IN- SHOWN IS
See HA-06-138 Rev 07/12
TB3 SUPERVISED AND INHERENTLY POWER
IN- LIMITED. CONNECT POWER LIMITED
CLASS-B CLASS-A
SUPPLY TO 24V+ & 24V-.

CLASS-B CLASS-A
!
U.L. LISTED SIGNALING DEVICES SELECT CLASS-A WIRING
BY SETTING THIS JUMPER
+ +
- -

CLASS-A OUTPUT WIRING

U.L. LISTED 1481 24VDC OUT TO NEXT


REGULATED, POWER INTERFACE MODULE
LIMITED SUPPLY FOR FIRE
PROTECTION SIGNALING S+ SC-
SERVICE FOR AUDIBLE
Hochiki America Corporation
DEVICES. REFER TO TB1 DCP-SOM-AI HOCHIKI
CONTROL PANEL CLASS A SUPERVISED OUTPUT MODULE

MANUFACTURER'S 24V + 24V+ SER. NO. 910300001

INSTALLATION 24V - U.L. LISTED


INSTRUCTIONS. 24V- IN S+ S+
COMPATIBLE
OUT+ FIRE CONTROL
IN SC- SC-
For Proper Installation PANEL
See HA-06-138 Rev 07/12
OUT- OUT S+

LEAVE TERMINALS "IN+"


IN+ OUT SC-
AND "IN-" UNCONNECTED
For Dry Indoor Use Only TB3
IN-
CLASS-B CLASS-A

CIRCUIT OUT+, OUT-, IN+, IN- SHOWN IS


SUPERVISED AND INHERENTLY POWER
LIMITED. CONNECT POWER LIMITED
SUPPLY TO 24V+ & 24V-.

CLASS-B CLASS-A
!
U.L. LISTED SIGNALING DEVICES SELECT CLASS-B WIRING
BY SETTING THIS JUMPER
+ E.O.L. DEVICE

- PART NUMBER
0400-03180

CLASS-B OUTPUT WIRING E.O.L. DEVICE


PART NUMBER
Hochiki America Corporation SOM-A & -AI 0400-03180 Specifications subject to change without notice.
DCP-SOM-R SUPERVISED OUTPUT MODULE

S P E C IF IC A T IO N S
S u p p ly Vo lta g e (S -SC ) 2 5 .3 ~ 3 9 VD C
A u xilia r y Su p p ly Vo lt a g e 24 VDC
A ve ra g e C u rr e n t 1 5 4 µA ( Ty p ica l)
C o n s u m p tio n M a x im u m : 6 m A (R e d A la rm
(O n S-S C L in e ) LED O n)
C u r re n t C o n s u m p tio n o n T yp ica l 1 .1 5 m A
A u xilia r y Po w e r L in e s
M a xim u m Ou tp u t C u rre n t 2 A @ 2 4 V D C P o w e r L im it e d
S o le n o id C u r re n t M a x im u m : 4 4 3 m A
C o n s u m p tio n
C o m p a t ib le So le n o id s AS C O : 8 2 1 0 G 2 0 7
Pa r ke r/Sk in n e r:
7 3 2 1 8 B N 4 U M L VN O C 1 1 1 C 2
E OL D e v ic e 1 0 K o h m s R e sist o r & 1 N 5 8 1 7
D io d e
S O M -R D im e n sio n s 4 . 2 ”W x 4 . 7 ”H x 1 .4 ”D
O p e ra tin g T e m p e ra tu re 3 2 °F (0 °C ) ~ 1 2 0 °F (4 9 °C )
M o u n tin g 4 ” sq u a r e e le ct rica l b o x
R e la tive H u m id ity 9 0 % R H N o n -C on d e n sin g

STANDARD FEATURES
DESCRIPTION
• UL 864 9th Edition Listed
The Supervised Output Module (DCP-SOM-R) is
• Flexible Pre-Action application
designed for Single-Interlock Pre-Action sprinkler
• Quick response to emergency conditions systems. During an alarm condition, the DCP-SOM-
• Operation parameters are maintained by the R output will operate which will trip a solenoid valve,
module, and individual communication with the allowing water to fill the sprinkler system piping.
control system during emergency conditions Water is not discharged until a sprinkler head
is not required operates due to heat from the fire. Pre-Action
• Contacts are rated 2.0 Amps @ 24VDC systems provide an added level of protection against
• Programming is highly flexible providing 16 inadvertent water discharge and are frequently
priority states plus zoning capability employed in water sensitive locations such as archival
Program status: vaults, fine art storage rooms, rare book libraries and
• LED will flash red or green computer centers.
The DCP-SOM-R requires 24VDC power from a UL
• Programmed device output is turned off, silenced, 1481 Listed, Regulated Power-Limited supply. The
or programmed to active continuously
24VDC power is supervised by the DCP-SOM-R. An
End-of-Line Device (EOLD) is included for supervision
of the output wiring and solenoid coil. The DCP-SOM-
R must be addressed from 1 – 127 prior to installation
PRODUCT LISTINGS on the SLC loop.
The DCP-SOM-R comes equipped with an SOM-R-DS
California Disable Key Switch. This switch is used, along with
State Fire a FRCME module, to disable the output of the DCP-
Marshal 3042214 SOM-R for system testing or maintenance. To ensure
S5694 7300-0410:150
proper operation of the DCP-SOM-R, follow all
installation, wiring, and programming instructions.
Specifications subject to change without notice.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0111 11/2012
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, addressable Supervised Output Module (DCP-
SOM-R). The modules shall be UL listed and compatible with FireNET 2127/4127 and FireNET Plus Fire Alarm
Control Panel. The device address shall be electrically programmable and stored in EEPROM. A bi-colored LED
shall indicate device status.The DCP-SOM-R shall be supplied with a plastic cover and shall be suitable for mounting
to a 4" square or double gang electrical back box. The DCP-SOM-R shall provide a monitor LED that is visible from
outside the cover plate. DCP-SOM-R is provided with a disable switch (SOM-R-DS), which shall be suitable for
mounting to a single gang electrical back box.

WIRING DIAGRAM

U.L. LISTED 1481 24VDC


REGULATED, POWER
ALL WIRING SHOWN ON TB1 LIMITED SUPPLY FOR FIRE
PROTECTION. REFER TO
IS SUPERVISED AND CONTROL PANEL
INHERENTLY POWER LIMITED MANUFACTURER'S
HOCHIKI AMERICA CORP.
INSTALLATION E.O.L. DEVICE
INSTRUCTIONS. PART NUMBER
0400-02590

SOLENOID

Hochiki America Corporation


DCP-SOM-R
TB2
SER. NO. XXXXXXXXX
ALL WIRING SHOWN ON TB2
TB1 24+ IS SUPERVISED AND BLACK
2

SC
GND
INHERENTLY POWER LIMITED
S
OUT+
For Dry Indoor Use Only
1

For Proper Installation, see HA-06-230 Rev 03/10


OUT -
SUPERVISED OUTPUT
OUTPUT TO
MODULE
COMPATIBLE
RED
RED

U.L. LISTED
SOLENOID
VALVE

IN IN OUT OUT
SOM-R

YELLOW
YELLOW

10KOhms EOL
U.L. LISTED
FireNET 4127 SOM-R-DS
or FireNET Plus Disable Key Switch
FIRE CONTROL
PANEL
IN-A
S+

SC-

IN-B

For Dry Indoor Use Only


SER. NO. XXXXXXXXX
DCP-FRCME-4
NOTE: Only the same size wire Hochiki America Corporation

from 12 to 22 AWG may be


For Propert Installation, see HA-06-195 Rev 10/08

AH-9755

connected to terminal block TB1and S5694


TB2 when more than one conductor
is being connected under each
terminal. Maximum of 2 conductor
per terminal.

FRCME

FIGURE 4
WIRING DIAGRAM

Hochiki America Corporation SOM-R Specifications subject to change without notice.


DCP-FRCME-P - FAST RESPONSE CONTACT MODULE

SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current 550µA (Typical)
Consumption 660µA (Alarm)
Programmable Input Monitoring Inputs
EOL Device 10K ohms Resistor
Max. Quantity Per Loop 127
Dimensions 3.0”W x 1.9”H x 0.5”D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting Single gang electrical box
Relative Humidity 90% RH Non-Condensing

DESCRIPTION
The Hochiki DCP-FRCME-P Fast Response Contact
Monitoring Modules are designed to be used with pull
STANDARD FEATURES stations, water flow switches, and other applications
requiring the monitoring of dry contact devices. The
• UL 864 9th Edition Listed interrupt driven Digital Communications Protocol (DCP)
• Single input contact monitor combines maximum communication reliability and fast
response to emergency conditions. The DCP-FRCME-
• Fast, reliable contact monitoring utilizing the P contact monitoring module does not require a sepa-
Hochiki DCP (Digital Communications Protocol) rate 24 VDC power source.
• 127 devices can be used per DCP loop
• Can be programmed to monitor Normally Open Each addressable contact monitoring module is
(NO) or Normally Closed (NC) contacts programmed with its own unique Signaling Line
Circuit (SLC) loop address. The device address is
• Operates on Class A or Class B SLC loop electrically programmable and stored in onboard
EEPROM. Up to 127 devices can be placed on the
Hochiki DCP SLC loop. The module supervises the wiring
to the contact with an End Of Line (EOL) resistor. It can
be programmed to monitor Normally Open (NO) or
Normally Closed (NC) contacts. If a fault condition
occurs in the wiring, the module sends a trouble status
PRODUCT LISTINGS signal to the fire alarm control panel. When a change of
status (contact changes state) is sensed by the DCP-
California FRCME-P, it sends an interrupt to the control panel
State Fire indicating that an alarm has occurred.
Marshal
7300-0410:150
The DCP-FRCME-P is small design and is suitable for
S5694 mounting in a single gang box.
MEA
284-91-E Vol. IV
3022559

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0123 07/2012
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, addressable contact monitoring modules
Hochiki DCP-FRCME-P. The modules shall be UL listed and compatible with the Hochiki Digital Communication
Protocol (DCP) supporting control panel. The device address shall be electrically programmable and stored in
EEPROM.

The DCP-FRCME-P shall fit inside a single gang electrical back box.

OUT TO TYPICAL WIRING FOR N/O CONTACTS


NEXT
MODULE
S SC
S U.L. LISTED E.O.L. DEVICE
COMPATIBLE PART NUMBER
POWER LIMITED

S (OUT)
FIRE ALARM EQUIPMENT

Hochiki America Corporation

Red
0400-03180
SC CONTROL
1S80

S (IN)
For Mounting Position/Proper Installation,

DCP-FRCME-P
SER. NO. 910300001
For Dry Indoor Use Only

SC (OUT)
Blk
PANEL
see HA-06-195 Rev 02/11

SC (IN)
IN-A
Wht
S5694

IN-B

U.L. LISTED
ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE E.O.L. DEVICE
DEVICES MAY BE USED . SUBJECT TO NFPA AND AHJ PART NUMBER
REQUIREMENTS. DO NOT MIX FIRE ALARM INITIATING 0400-03180
OR SUPERVISORY ON THE SAME MODULE
ALL CIRCUIT ARE SUPERVISED AND INHERENTLY POWER LIMITED

Hochiki America Corporation DCP-FRCME-P Specifications subject to change without notice.


DCP-FRCME-M - FAST RESPONSE CONTACT MODULE

SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current 339μA (Typical)
Consumption 358μA (Alarm)
Programmable Input 1 Monitoring Inputs
EOL Device 10K Ohms Resistor
Max. Quantity Per Loop 127
Dimensions 1.75"W x 2.37"H x 0.5"D
Operating Temperature 32°F (0°C) 120°F (49°C)
Mounting 2" electrical box
Relative Humidity 90% RH Non-Condsensing

DESCRIPTION
The Hochiki DCP-FRCME-M Fast Response Contact
STANDARD FEATURES Monitoring Modules are designed to be used with pull
stations, water flow switches, and other applications
• UL 864 9th Edition Listed requiring the monitoring of dry contact devices. The
• Single input contact monitor interrupt driven Digital Communications Protocol (DCP)
combines maximum communication reliability and fast
• Fast, reliable contact monitoring utilizing the response to emergency conditions. The DCP-FRCME-
Hochiki DCP (Digital Communications Protocol) M contact monitoring module does not require a sepa-
• 127 devices can be used per DCP loop rate 24 VDC power source.
• Can be programmed to monitor Normally Open
(NO) or Normally Closed (NC) contacts Each addressable contact monitoring module is
• Operates on Class A or Class B SLC loop programmed with its own unique Signaling Line
• Accepts up to 12 AWG wire Circuit (SLC) loop address. The device address is
electrically programmable and stored in onboard
EEPROM. Up to 127 devices can be placed on the
Hochiki DCP SLC loop. The module supervises the wiring
to the contact with an End Of Line (EOL) resistor. It can
be programmed to monitor Normally Open (NO) or
Normally Closed (NC) contacts. If a fault condition
occurs in the wiring, the module sends a trouble status
signal to the fire alarm control panel. When a change of
status (contact changes state) is sensed by the DCP-
FRCME-M, it sends an interrupt to the control panel
PRODUCT LISTINGS indicating that an alarm has occurred.

California
State Fire The DCP-FRCME-M is a small design and is suitable
Marshal 3042214 for mounting in a single gang box.
S5694 7300-0410:150

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0113 01/2014
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, addressable contact monitoring modules
Hochiki DCP-FRCME-M. The modules shall be UL listed and compatible with the Hochiki Digital Communication
Protocol (DCP) supporting control panel. The device address shall be electrically programmable and stored in
EEPROM.

The DCP-FRCME-M shall be suitable for mounting to a single gang electrical back box.

WIRING DIAGRAM

OUTPUT TO NEXT INTERFACE


MODULE ON THE SLC LOOP

U.L. LISTED
COMPATIBLE
FIRE CONTROL
PANEL

TB1 WIRING SHOWN IS SUPERVISED AND INHERENTLY POWER LIMITED.

WIRING DIAGRAM FOR CLASS B ( STYLE B):


TYPICAL WIRING FOR N/O CONTACTS IN CLASS B (STYLE B)

E.O.L. DEVICE
PART NUMBER
0400-03180

HOCHIKI AMERICA CORP.


E.O.L. DEVICE
PART NUMBER NOTE: Only the same size wire
0400-03180
from 12 to 22 AWG may be
connected to the terminal block TB1
when more than one conductor is
being connected under each
terminal. Maximum of 2 conductor
per terminal.

TYPICAL WIRING FOR N/C CONTACTS

HOCHIKI AMERICA CORP. E.O.L. DEVICE


E.O.L. DEVICE PART NUMBER
0400-03180
PART NUMBER
0400-03180

NOTE: For Normally Closed (N/C) contact monitoring, the FRCME-M can only be used to generate a trouble
condition, not an alarm or supervisory.
NOTE: SLC Circuit is in reference to S, and SC for Class A/B wiring diagram.
NOTE: ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE
DEVICES MAY BE USED, SUBJECT TO NFPA AND AHJ
REQUIREMENTS. DO NOT MIX FIRE ALARM AND SUPERVISORY
INITIATING DEVICES ON THE SAME MODULE.

Hochiki America Corporation FRCME-M Specifications subject to change without notice.


DCP-FRCMA/-I - FAST RESPONSE CONTACT MODULE
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current Consumption 630μA (Typical)
6.3mA (Alarm)
SCI On Resistance
40m ohm Max. (Normal Condition)
SCI Fault Detection Threshold 12 volts (Typical)
SCI Isolation Current
(Short Circuit Condition) 10mA (Typical)
Maximum Quantity Per Loop 127
Dimensions 4.2"W x 4.7"H x 1.4"D
Ambient Temperature 32°F (0°C) ~ 120° F (49°C)
Mounting 4" square electrical box
Relative Humidity 90% RH Non-condensing
STANDARD FEATURES
• Single input contact monitor DESCRIPTION
• Fast, reliable contact monitoring utilizing the The Hochiki FRCMA/-I Fast Response Contact Monitoring
Hochiki DCP (Digital Communications Protocol) Modules are designed to be used with pull stations, water
flow switches, and other applications requiring the moni-
• Two different mounting configurations toring of dry contact alarm initiating devices. The interrupt
• 127 devices can be used per DCP loop driven Digital Communications Protocol (DCP) combines
• Bi-colored indicating LED provides module status maximum communication reliability and fast response to
(Both Models) emergency conditions. Two different mounting configura-
tions are provided to meet a wide range of applications.
• Yellow LED indicates a short circuit condition The FRCMA/-I contact monitoring module does not require
(FRCMA-I only) a separate 24 VDC power source.
• Can be programmed to monitor Normally Open
(NO) or Normally Closed (NC) contacts in Class B
Each addressable contact monitoring module is
• Operates on Class A or Class B SLC loop programmed with its own unique Signaling Line Circuit
• Accepts up to 14 AWG wire (SLC) loop address. The device address is electrically
• UL 864 Listed programmable and stored on onboard EEPROM. Up to
127 devices can be placed on the Hochiki DCP SLC loop.
The module supervises the wiring to the contact with an
End Of Line (EOL) resistor in Class B mode. It can be
programmed to monitor Normally Open (NO) or Normally
Closed (NC) contacts. If a fault condition occurs in the
PRODUCT LISTINGS wiring, the module sends a trouble status signal to the fire
alarm control panel. When a change of status (contact
California changes state) is sensed by the FRCMA/-I, it sends an
State Fire interrupt to the Fire Alarm Control Panel indicating that an
Marshal 3036830 alarm has occurred. FRCMA-I version has built-in integrated
7300-0410:150 SCI circuitry. In the event of a short on the S-SC line, the
S5694 SCI circuit will activate and its yellow LED indicator will be
turned on steady and the module will report the short circuit
Specifications subject to change without notice. condition to the Fire Control Panel.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F098 03/2014
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, addressable contact monitoring modules Hochiki
DCP-FRCMA/-I. The modules shall be UL listed and compatible with the Fire alarm control panel. The device address
shall be electrically programmable and stored in EEPROM.

The FRCMA/-I shall be supplied with a plastic face plate and shall be suitable for mounting to a 4" square or double
gang electrical back box. The FRCMA/-I shall provide a monitor LED that is visible through the face plate. FRCMA-I
shall provide a SCI LED that is visible through the face plate.

Back side of FRCMA Back side of FRCMA-I


WIRING DIAGRAM
FRCMA/-I:
WIRING DIAGRAMS FOR CLASS A (STYLE D) WIRING NOTE: CLASS A can only monitor N/O contacts

TB1 TB2

TB1 AND TB2 SHOWN IS SUPERVISED


AND INHERENTLY POWER LIMITED
FIGURE 2A.

WIRING DIAGRAMS FOR CLASS B (STYLE B) WIRING


TYPICAL WIRING FOR N/O CONTACTS IN CLASS B

E.O.L. DEVICE
PART NUMBER
0400-03180

TB1 TB2

HOCHIKI AMERICA CORP.


ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE E.O.L. DEVICE
DEVICES MAY BE USED . DO NOT MIX FIRE ALARM PART NUMBER
INITIATING OR SUPERVISORY ON THE SAME MODULE 0400-03180

FIGURE 2B

TYPICAL WIRING FOR N/C CONTACTS


(N/C AVAILABLE ONLY FOR CLASS B)
TB1 TB2

NOTE: If configured for class B, N/C contacts, this cannot be


an alarm or supervisory.

E.O.L. DEVICE HOCHIKI AMERICA CORP.


PART NUMBER
0400-03180 E.O.L. DEVICE
PART NUMBER
0400-03180
FIGURE 2C
TB1 AND TB2 SHOWN IS SUPERVISED
AND INHERENTLY POWER LIMITED
Hochiki America Corporation DCP-FRCMA/A-I Specifications subject to change without notice.
SCI - SHORT CIRCUIT ISOLATOR
OPERATION
* Class A Configuration Wiring:
The DCP-SCI short circuit isolator should be located
between any devices on the SLC loop. In the event of
a short on the SLC loop, the two adjacent isolators
(closest isolators to the left and right of the shorted
section) will activate and their respective LED indica-
tors will be turned on. All devices between the active
short circuit isolators will lose communication. This
will prevent entire loop failure. Upon removal of the
short condition, the DCP-SCIs will automatically
restore the entire loop to the normal operating state.

* Class B Configuration Wiring:


The DCP-SCI short circuit isolator should be located
between any devices on the SLC loop. In the event of
a short on SLC loop, an isolator closest to the shorted
STANDARD FEATURES section will activate and the LED will be turned on. All
the devices beyond the shorted section will lose
• Can be placed at any location on SLC loop
communication. Upon removal of the short condi-
• Checks the line for short circuit at power up. If the tion, the DCP-SCI will automatically restore the entire
line is normal, the relay will be returned on. If a
loop to the normal operating state.
line short is detected, the relay remains open
• Indication of a single short circuit by a yellow LED For the best performance of DCP-SCI short circuit
isolator, use class A configuration.

SPECIFICATIONS WIRING:
Supply Voltage 33 ~ 41 VDC Note: All wiring must conform to local codes, ordi-
(S-SC) nances and regulations.
Average Current 270µA (Typical) 1. Install module wiring in accordance with job draw-
Consumption 10 mA (Active Short Condition) ings and appropriate wiring diagram.
Visual Indicator Normal: Off 2. Secure the module to an approved electrical box
(Yellow LED) Active: On (supplied by installer).
Dimensions 4.2”W x 4.7”H x 1.4”D
Weight 1.4 oz MOUNTING REQUIREMENTS: 4" SQ Electrical box
Operating 32°F (0°C) ~ 120°F (49°C) or double gang.
Temperature
Mounting 4” square electrical box PRODUCT LISTINGS
Relative Humidity 90% RH Non-Condensing
California
State Fire
Marshal
CS943 7300-0410:150
S5694
MEA
284-91-E Vol. IV
Specifications subject to change without notice.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0008 10/2014
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, the Hochiki DCP-SCI short circuit isolator. The
modules shall be UL listed compatible with Hochiki Digital Communications Protocol (DCP) supporting control panel
loops. The isolator module must be suitable for mounting in a standard 4" square electrical box or double gang. The
isolator module must provide a yellow LED for indication of status.

Back side of a DCP-SCI

WIRING DIAGRAM

TB1
SER. NO. XXXXXXXXX

UL LISTED
SIGNALING DEVICE
ISSUE NO. AH-9774

(IN) S
DCP-SCI

(IN) SC

(OUT) SC
(OUT) S
COMPATIBLE
S5694

CONTROL
PANEL

SHORT CIRCUIT ISOLATOR


--
SER. NO. XXXXXXXXX

TB1
SIGNALING DEVICE
ISSUE NO. AH-9774
LISTED

(IN) S
DCP-SCI

(IN) SC
(OUT) S
GROUP OF VARIOUS DCP MODULES
(OUT) SC

-
S5694

OPTIONAL RETURN LINE


GROUP OF VARIOUS DCP SENSORS (NOT REQUIRED)
++ +

SHORT CIRCUIT ISOLATOR


TB1

(OUT) SC
(OUT) S
(IN) SC
(IN) S

SER. NO. XXXXXXXXX


DCP-SCI
ISSUE NO. AH-9774
SIGNALING DEVICE
LISTED
S5694

SHORT CIRCUIT ISOLATOR

TYPICAL WIRING DIAGRAM EXAMPLE, CONNECTED ALL WIRING SHOWN IS SUPERVISED


AND INHERENTLY POWER LIMITED.
TO A COMPATIBLE LISTED CONTROL PANEL ANY COMBINATION OF MODULES
AND/OR SENSORS MAY BE PLACED
BETWEEN ISOLATORS

Hochiki America Corporation DCP-SCI Specifications subject to change without notice.


DCP-R2ML/-I & DCP-R2MH/-I - DUAL RELAY MODULE
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current Consumption 350μA (Typical)
405μA (Alarm)
Contacts 2 Independently Controlled Form C
R2ML: 2A @ 30VDC / 0.5A @ 120 VAC
R2MH: 8A @ 30VDC / 4.8A @ 250VAC
SCI On Resistance
40m ohm Max. (Normal Condition)
SCI Fault Detection Threshold 12 volts (Typical)
SCI Isolation Current
(Short Circuit Condition) 10mA (Typical)
Maximum Quantity Per Loop 127
Dimensions 4.2"W x 4.7"H x 1.4"D

STANDARD FEATURES Ambient Temperature 32°F (0°C) ~ 120°F (49°C)


Mounting 4" square electrical box
• Provides two independently configurable Form C Relative Humidity 90% RH Non-condensing
contacts per address
• Contacts are rated as follow: DESCRIPTION
R2ML: 2A @ 30 VDC / 0.5A @ 120 VAC
R2MH: 8A @ 30VDC / 4.8A @ 250 VAC The Dual Relay Modules (R2ML/H Series) have been
• Up to127 devices can be used on each SLC loop designed to provide flexibile and quick response to
• Visible Bi-colored LED is software controlled and emergency conditions. The R2ML/H Series allows
can be programmed to blink red or green when independent control of two form C contacts for a variety of
polled. The LED can be latched on when activated. normally open and normally closed contact applications
(For All Models) such as fan operation, elevator recall, door closure, and
• Yellow LED indicates a short circuit condition auxiliary notification.
(R2ML-I & R2MH-I only)
• Programming is highly flexible providing 16 priority Each R2ML/H Series module provides independent control
states plus zoning capability of two Form C contacts while utilizing one SLC (Signaling
• Operates on Class A or Class B SLC loop Line Circuit) address. The R2ML/H Series modules have a
• UL 864 Listed highly configurable programming algorithm that allows the
user to set up groups of devices (zoning) for simultaneous
operation of multiple R2ML/H modules. Each module has
16 priority states that are programmed. The operating
PRODUCT LISTINGS parameters are maintained by the module and do not require
individual communication with the control panel during the
California
emergency condition to operate. The control panel
State Fire
broadcasts the control command on the SLC loop and the
Marshal 3036830 R2ML/H Series modules do the rest based on their custom
S5694 7300-0410:150
configuration. Since mechanically latching relays are used
within the R2ML/H Series modules, a separate 24VDC
Specifications subject to change without notice. power source is not required.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F097 03/2014
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, the Hochiki DCP-R2ML/H Series addressable
relay modules. The modules shall be UL listed compatible with Hochiki Digital Communications Protocol (DCP)
supporting control panel loops. The relay module must provide two Form C dry contacts rated as follows: R2ML - 2A
@ 30 VDC or 0.5A @ 120 VAC and R2MH - 8A @ 30VDC or 4.8A @ 250 VAC. The relay module must be suitable
for mounting in a standard 4" square electrical box. The relay module must provide a bi-colored LED for indication of
status. R2M-LI/-HI shall provide an SCI LED that is visible through the face plate.

Back side of R2ML Back side of R2ML-I


WIRING DIAGRAM
SCI VERSION

OUTPUT TO NEXT INTERFACE


MODULE IN THE SLC LOOP Hochiki America Corporation
DCP-R2MH-I NO1
TB2 S, SC WIRING
POWER LIMITED
SERIAL NO. XXXXXXXXX

COM1 SET 1
OUT_SC- POWER
LIMITED

OUT_S+ NON NC1 (FORM "C" CONTACTS)


POWER
For Proper Installation, LIMITED (NON-SUPERVISED)
see HA-06-148 01/09
U.L. LISTED IN_ SC- NO2
COMPATIBLE
FIRE CONTROL CROSS OUT
TYPE NOT
PANEL IN_S+ USED
COM2 SET 2

NC2

FIGURE 1.
WIRING DIAGRAM

NON-SCI VERSION

Hochiki America Corporation


DCP-R2MH NO1
TB2 S, SC WIRING SERIAL NO. XXXXXXXXX
POWER LIMITED
OUTPUT TO NEXT INTERFACE COM1 SET 1
MODULE IN THE SLC LOOP POWER
LIMITED
For Proper Installation,
see HA-06-148 01/09 NC1
NON
POWER (FORM "C" CONTACTS)
LIMITED (NON-SUPERVISED)
NO2
U.L. LISTED SC -
COMPATIBLE CROSS OUT
TYPE NOT
FIRE CONTROL S + USED
COM2 SET 2
PANEL
NC2

FIGURE 2.
WIRING DIAGRAM

Hochiki America Corporation DCP-R2ML/-LI & DCP-R2MH/-HI Specifications subject to change without notice.
DIMM - DUAL INPUT MONITOR MODULE

SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current 600µA (Typical)
Consumption 720µA (Alarm)
Programmable Inputs 2 Independent Monitoring Inputs
EOL Device 22K ohms Resistor
Max. Quantity Per Loop 127
Dimensions 4.2”W x 4.7”H x 1.4”D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 4” square electrical box
Relative Humidity 90% RH Non-Condensing

DESCRIPTION
STANDARD FEATURES
The Hochiki Dual Input Monitor Module (DIMM) is de-
• UL 864 9th Edition Listed signed for use on a UL listed Fire Alarm Control Panel.
• Fast, reliable contact monitoring utilizing the It provides two independent contact monitoring cir-
cuits while only utilizing one address on the SLC loop.
Hochiki DCP (Digital Communications Protocol) Up to 127 devices can be placed on a single SLC
• 127 devices can be used per DCP loop loop. The device address is uniquely stored on an
onboard EEPROM. The module can be programmed
• Bi-colored indicating LED provides module status
to monitor Normally Open (NO) or Normally Closed
• Dual input contact monitor (NC) contact fire alarm and supervisory devices. The
• Can be programmed to monitor Normally Open interrupt driven Digital Communication Protocol (DCP)
(NO) or Normally Closed (NC) contacts combines maximum communication reliability and
fast response to emergency conditions. The module
• Operates on Class A or Class B SLC loop has a single bi-colored LED to indicate device sta-
• Accepts up to 14 AWG wire tus. It fits into a standard 4" square or double gang
electrical back box.

PRODUCT LISTINGS
California
State Fire
Marshal
3033215
7300-0410:150
S5694

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0003 07/2010
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, Hochiki DCP-DIMM addressable contact
monitoring modules. The modules shall be UL listed and compatible with the Hochiki Digital Communications
Protocol (DCP) supporting control panel loops. The device address shall be electrically programmable and stored in
EEPROM. The contact module must be suitable for mounting in a standard 4" square electrical box or double gang.
The contact module must provide a bi-colored LED to indicate device status.

Back Side of a DCP-DIMM

WIRING DIAGRAM

E.O.L. DEVICE 22K Hochiki America Corporation


PART NUMBER DCP-DIMM OUT TO NEXT MODULE
0400-01000 TB2 Dual Input Monitor Module
TYPICAL WIRING FOR N/O CONTACTS ONLY SER. NO. XXXXXXXXX
+
TB1
Input A
E.O.L. DEVICE 22K
PART NUMBER
0400-01000 S U.L. LISTED
COMPATIBLE
+ SC
FIRE CONTROL
ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE Input B PANEL
DEVICES MAY BE USED, SUBJECT TO NFPA AND AHJ
REQUIREMENTS.
Dual Input Monitor
Module ALL WIRING SHOWN IS SUPERVISED
AND INHERENTLY POWER LIMITED.

Hochiki America Corporation DIMM Specifications subject to change without notice.


DCP-CZM CONVENTIONAL ZONE MODULE

SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Auxiliary Supply Voltage 18.8 ~ 27.2 VDC
Average Current Consumption
(On S-SC Line) 670µA
2-Wire Detector Loop Current
Standby Detector Load 1mA Max.
From Auxiliary Supply 60mA Max.
EOL Device 4.7K ohms Resistor
Max. Quantity Per Loop 127
Alarm Threshold Level <1.5K ohms
Wiring Threshold Level >2.5K ohms & <6K ohms
Open Circuit Threshold Level >10K ohms
Max. 2-Wire Conventional
Detector (Loop Resistance) 50 ohms (total wire length)
STANDARD FEATURES Dimensions 4.2”W x 4.7”H x 1.4”D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
• UL 864 9th Edition Listed Mounting 4” square electrical box
• Provides an address point for a zone of up to 25
Relative Humidity 90% RH Non-Condensing
conventional smoke detectors
• Blinks green when polled. Latched on red (controlled
by panel) when activated
• Device address can be programmed with a DESCRIPTION
handheld programmer. Device address- ranges
from 1 to 127 The Hochiki Conventional Zone Module (DCP-CZM) is
designed for use on an analog addressable Fire Alarm
• Compatible with Class B and Class A wiring
system. Up to 127 devices can be placed on a single
• Auxiliary power source provides power for the zone
SLC loop. The device address is uniquely stored on an
of detectors
onboard EEPROM. The module allows the panel to
• Compatible with conventional detectors, SLR, SIJ, interface and monitor two-wire conventional detectors
SLK, SLV, DCD, DFE and SIH series or pull stations. Each DCP-CZM transmits the status
• Compatible with TH series linear heat cables from on one zone of devices (25 maximum per zone) back
Proline Protection Systems to the panel. It supervises the power supply as well
as the entire zone of devices. Status conditions are
reported as normal, open or alarm. All 2-wire smoke
PRODUCT LISTINGS detectors must be UL listed as compatible to be
interfaced with the DCP-CZM. The interrupt driven
California Digital Communication Protocol (DCP) combines
State Fire maximum communication reliability and fast response
Marshal to emergency conditions. The module has a single bi-
3033215
7300-0410:150 colored LED to indicate device status. It fits into a
S5694 standard 4" square or double gang electrical back box.

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0004 12/2013
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, Conventional Zone Module (DCP-CZM). The
modules shall be UL listed and compatible with the Hochiki America Analog Control Panel Protocol. The device
address shall be electrically programmable and stored in EEPROM. A bi-colored LED shall indicate device status.
The DCP-CZM shall be supplied with a plastic cover and shall be suitable for mounting to a 4" square or double gang
electrical back box. The DCP-CZM shall provide a monitor LED that is visible from outside the cover plate.

WIRING DIAGRAM
NFPA STYLE D WIRING DIAGRAM EXPLODED VIEW

3-4: CLASS A

OPTIONAL BRANCH CIRCUIT TO


NEXT INTERFACE MODULE.
MODULE SUPERVISES SUPPLY JP2
Hochiki America Corporation CLASS A
VOLTAGE AND DETECTOR LOOP.
DCP-CZM
S SC
TB1 SER. NO. 210300001 TB2
NOTE: ENSURE JUMPER IS IN CORRECT POSITION
U.L. LISTED FOR WIRING CONFIGURATION. (POSITION 3-4)
COMPATIBLE SC SC IN+
FIRE CONTROL S IN-
PANEL S

24V- OUT+
UL LISTED 1481 -
24VDC + 24V+ For Dry Indoor Use Only
OUT-
REGULATED For Proper Mounting/Installation See
MAX. 25 CONVENTIONAL
POWER SUPPLY, HA-06-101 11/13 DETECTORS
LISTED FOR FIRE 24- 24V+
PROTECTION
NEXT DEVICE
WITH BATTERY ALL WIRING IS SUPERVISED AND POWER LIMITED.
BACKUP. EB
DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR
SECURITY DEVICES ON THE SAME MODULE.
FIGURE 3.

EXPLODED VIEW
NFPA STYLE B WIRING DIAGRAM

1-2: CLASS B

OPTIONAL BRANCH CIRCUIT TO


NEXT INTERFACE MODULE.
MODULE SUPERVISES SUPPLY JP2
VOLTAGE AND DETECTOR LOOP. Hochiki America Corporation CLASS B
DCP-CZM NOTE: ENSURE JUMPER IS IN CORRECT POSITION
S SC
TB1 TB2
U.L. LISTED FOR WIRING CONFIGURATION. (POSITION 1-2)
COMPATIBLE SC SC IN+
FIRE CONTROL
PANEL S S IN-
24V- OUT+ HOCHIKI AMERICA CORP.
- E.O.L. DEVICE 4.7K
E.O.L. DEVICE 4.7K
UL LISTED 1481 PART NUMBER
0400-03190
+ 24V+ OUT- PART NUMBER
24VDC 0400-03190
REGULATED
MAX. 25 CONVENTIONAL
POWER SUPPLY, DETECTORS
LISTED FOR FIRE 24- 24V+ TB1/TB2 ARE SUPERVISED AND POWER LIMITED.
PROTECTION CONVENTIONAL ZONE
MODULE
NEXT DEVICE
WITH BATTERY
BACKUP.
DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY,
EB
SECURITY DEVICES OR LINE TYPE HEAT CABLES ON
THE SAME MODULE.
NOTE: Only the same size wire INSTALL ONLY DETECTORS LISTED AS UL
from 12 to 22 AWG may be FIGURE 3. COMPATIBLE WITH THE CONVENTIONAL ZONE
connected terminal block TB1 MODULE (CZM) AS REFERENCED IN THE CHART
when more than one conductor is BELOW.
being connected under each
terminal. Maximum of 2 conductor INSTALLATION WIRING SHALL NOT EXCEED 50
per terminal. OHMS (12-22 AWG) WHEN USING CONVENTIONAL
DETECTORS

Compatible Two Wire Detectors for use with the CZM with zone identifier A:
Detector Model Detector Detector Type Base Model Base Max
Identifier Indetifier Detectors
SLK-24F HD-3 Photoelectric HSB-224 HB-53 25
SLK-24F HD-3 Photoelectric HSB-220 HB-56 25
SIH-24F HD-3 Ionization HSB-224 HB-53 25
SIH-24F HD-3 Ionization HSB-220 HB-56 25
SLR-24H HD-3 Photoelectric w/heat NS4-224, NS6-224 HB-5 25
SLR-24H HD-3 Photoelectric w/heat NS4-220, NS6-220 HB-3 25
SLR-24V HD-3 Photoelectric NS4-224, NS6-224 HB-5 25
SLR-24V HD-3 Photoelectric NS4-220, NS6-220 HB-3 25
SLR-835/-835W HD-3 NS4-224, NS6-224 HB-5 18
Photoelectric (8-35V)
NS4-224W, NS6-224W
SLR-835/-835W HD-3 Photoelectric (8-35V) NS4-220, NS6-220 HB-3 18
NS4-220W, NS6-220W
HD-5 Photoelectric (8-35V) NS4-224, NS6-224 HB-5 18
SLR-835H/-835HW
w/thermal NS4-224W, NS6-224W
HD-5 Photoelectric (8-35V) NS4-220, NS6-220 HB-3 18
SLR-835H/-835HW
w/thermal NS4-220W, NS6-220W
SLR-835B-2/-2W HD-6 Photoelectric (8-35V) (baseless) N/A N/A 18
SLR-835BH-2/-2W HD-6 Photoelectric (8-35V) N/A N/A 18
w/thermal (baseless)
SIJ-24 HD-3 Ionization NS4-224, NS6-224 HB-5 25
SIJ-24 HD-3 Ionization NS4-220, NS6-220 HB-3 25
DCD-135/-190 HD-3 Heat Fixed Temp/Rate of Rise NS4-224, NS6-224 HB-5 25
DCD-135/-190 HD-3 Heat Fixed Temp/Rate of Rise NS4-220, NS6-220 HB-3 25
DFE-135/-190 N/A Heat Fixed Temp HSC-224L HB-62 25
DFE-135/-190 N/A Heat Fixed Temp HSC-220L HB-64 25
SLV-24/-24N/-24V HD-3 Photoelectric NS4-224, NS6-224 25
NS4-224W, NS6-224W HB-5
SLV-24/-24N/-24V HD-3 Photoelectric NS4-220, NS6-220 25
NS4-220W, NS6-220W HB-3

Compatible Linear Heat Detection Cable for use with the CZM:
Manufacturer Model Description Maximum Lenght
Proline Protection Systems TH 68 Fixed Temp. line type heat detector cable 155 F (68 C) 8,000ft. (2,438m)
Proline Protection Systems TH 88 Fixed Temp. line type heat detector cable 190 F (88 C) 8,000ft. (2,438m)
Proline Protection Systems TH 105 Fixed Temp. line type heat detector cable 221 F (105 C) 8,000ft. (2,438m)

Hochiki America Corporation CZM Specifications subject to change without notice.


RAI-LED
Remote Alarm Indicator

SPECIFICATIONS
Supply Voltage 17 ~ 41 VDC
Current 7mA (Alarm)
Consumption
Dimensions 2.73”W x 4.5”H x 0.15”D
Operating 32°F (0°C) ~ 120°F (49°C)
Temperature
Relative Humidity 90% RH Non-Condensing
Environment For Dry Indoor Use Only
Mounting Single gang electrical box
Compatible Bases HSB-NSA-6, YBN-NSA-4,
ASB, SCI-B4, SCI-B6
Compatible AIE-EA, ALG-V, ALK-V, ATG-
Detector/Sensors EA, ACA-V

RAI-LED
STANDARD FEATURES

• UL Listed
• Compatible with analog addressable detectors,
sensors and bases
• Compatible with FireNET 2127/4127 and
FireNET Plus FACPs

DESCRIPTION

RAI-LED is a remote alarm indicator that provides


visual alarm indication for analog addressable sensors
that are installed in concealed locations or where the
sensor's alarm indicator is not visible to responding
personnel. RAI-LED is intended to be mounted on to a
single gang electrical box.

PRODUCT LISTINGS

California
State Fire
Marshal Pending
S3516 7300-0410:0201

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0178 06/2013
HCA-2, HCA-2D, HCA-4, HCA-4D, HCA-8, HCA-8D
CONVENTIONAL FIRE ALARM CONTROL PANEL

STANDARD FEATURES

• UL864 9th Edition / NFPA Compliant


• Fully programmable using simple menu options
• Simple, single board construction
• Installer friendly and supports flush or surface mount
without a separate trim-ring
• Built-in two-line (16 Characters for each line) LCD
display provides easy to read information
• 15 Key control buttons for easy programming, reset
and silencing.
• Real time clock
HCA FRONT VIEW • Event History log (256 events) with Date/Time stamp,
which can be viewed from LCD display
• Compatible with wide range of detection devices
• 4 Programmable Supervised NAC outputs
DESCRIPTION • 6.5 Amp power supply
• Switchable 120/240VAC 50/60 Hz Power supply
The HCA series is available in a 2, 4, or 8 zone • 5 Programmable output patterns for NAC circuits
conventional panel design which is in accordance with
• Gentex Sync Protocol Built-in
UL 864 9th Edition Listing Detection and Fire Alarm
Systems – Control and Indicating Equipment. • Built-in Dialer for HCA-2D, HCA-4D and HCA-8D Only
• Supports Releasing of Agents & Water on HCA-4 &
The HCA series are fully programmable using simple HCA-8 models
front panel menu options. HCA supports releasing of • Three programmable general purpose relays
agent (FM-200, 3M Novec, etc) and water (Pre-action, • Dedicated alarm and trouble relays
Deludge, etc.) on the HCA-4 and HCA-8 models only. • Built-in walk test feature
Also, Built-in Dialer on HCA-2D, HCA-4D and HCA-8D • Panel Dimension: 14.57" (W) x 15.47" (H) x 4.41" (D)
models only. This conventional control panel offers • Supports up to two 12V, 18Ah Backup batteries
programing features to the user. The panel is a single • Supports one Remote Annunciator via RS-485
board construction, which is installer friendly. The
panel is compatible with a wide range of Hochiki
America's detection devices.

PRODUCT LISTINGS

California
State Fire
Marshal
7165-0410:183

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0117 08/2014
SPECIFICATIONS
Supply Voltage 120VAC (50hz/60hz) or 240VAC (50hz/60hz)
Power Supply DC Rating 24V @ 6.5 Amps (HCA-2, HCA-2D, HCA-4/8, HCA-4D/8D)
Number of Zones HCA-2 (2 Zones), HCA-4 (4 Zones), HCA-8 (8 Zones)
NAC Outputs (4) 2.5 Amp @ 24VDC Special Application, Class B
Relay Outputs (5) 3 Amps @ 30VDC, 3A @ 240VAC
Display 2 line x 16 character LCD
Charger Current 0.98A @ 22VDC max.
Battery 2 x 12VDC, 18AH max.
Operating Temperature 32°F ~ 120°F (0°C ~ 49°C)
Operating Humidity 95% RH Non-Condensing
Color Red
Dimension 14.57"W X 15.47"H X 4.41"D (370mm X 393mm X 112mm)
Weight 14 lbs. (6.4Kg)

HOCHIKI AMERICA COMPATIBLE DEVICES


MODEL DESCRIPTION MAX. # PER ZONE
DETECTORS
SLR-835 Photoelectric high velocity smoke detector 20
SLR-24V Photoelectric high velocity smoke detector 20
SLR-24H Combined Photoelectric smoke / Heat detector 20
DSC-EA Rate of rise heat detector 20
DCD-135 135° Fixed temperature rate of rise heat detector 20
DCD-190 190° Fixed temperature rate of rise heat detector 20

BASES
NS6-224 6" base, 43mA draw, 24V 20
NS4-224 4" base, 43mA draw, 24V 20
NS6-100 6" base, 150mA draw, 24V 20
NS4-100 4" base, 150mA draw, 24V 20

PULL STATION
HPS-SAK/HPS-DAH Conventional Manual Pull Station 25
HPS-SAH/HPS-DAK Conventional Manual Pull Station

RELEASING ACCESORY
0400-02590 Releasing EOL Module (Included for HCA-4, -8) 1
PB-SA Abort Switch 1
HPS-DAK-SR Fire Suppression Release Pull Station 1

COMPATIBLE ACTUATORS & SOLENOIDS


131-035 Electrical Actuator (Sea-fire) 1
SOL EA45 Electrical Actuator (Sevo Systems) 1
PA0036-3 Electrical Actuator (TLX Technologies) 1
73218BN4UNLVNOC1111C2 Solenoid (Parker/Skinner) 1
LV2LBX25 Solenoid (Parker/Skinner) 1
X5H65100 (24Volt) Solenoid (Parker/Skinner) 1
T8210A107 Solenoid (ASCO) 1
R8210A107 Solenoid (ASCO) 1
HV2185328 Solenoid (ASCO) 1
8210A107 Solenoid (ASCO) 1
753-E FireLock 300 psi Solenoid (Victaulic) 1
11591 Solenoid (Viking) 1

Hochiki America Corporation HCA Series CONVENTIONAL FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FIRE ALARM CONTROL UNITS - HCP-1000 SERIES
STANDARD FEATURES
 UL 864 9th edition Listed
 Large system capacity
 Modular design
 Each indicating circuit can be configured as Silence Able
or Non-Silence Able
 Audible may be configured as Steady, Temporal Code,
California Code or March Time
 Each initiating circuit can be configured as Alarm,
Supervisory, Waterflow or Trouble
DESCRIPTION  Two LEDs per initiating circuit; one for Trouble and one for
Status
Hochiki’s HCP-1000 Series microprocessor based fire
alarm control panels are multi-zone units designed for  Initiating and indicating circuits may be individually
maximum flexibility and easy installation and operation. disconnected by a DIP switch
Fully configurable from the front panel using push  Configurable Signal Silence Inhibit, Auto Signal Silence,
buttons and DIP switches, the HCP-1000 Series Two-Stage Operation and One Man Walk Test
enables the user to configure the system to meet their
 Subsequent Alarm, Supervisory and Trouble operation
specific requirements. With a large capacity of
supervised Class A (Style D) or Class B (Style B)  Two outputs for 4 wire resettable smoke power supply
initiating circuits and supervised Class A (Style Z) or (200 mA Max. each)
Class B (Style Y) indicating circuits, the HCP-1000  Auxiliary relay contacts for Common Alarm and Common
Series is designed to meet virtually all applications. Supervisory as well as a Common Trouble Relay (Each
relay contact Form C, 28 VDC @ 1 Amp (resistive))
The HCP-1000 Series consists of a main fire alarm
chassis which houses and controls all other modules.  RS-485 Interface for HRA-1000 Remote Multiplex Annun-
Additional modules may be installed to configure the ciators
system to meet any requirements that the user may  Interface for Remote Trouble Indicator
have. The HCP-1000 Series allows for additional
indicating circuits, initiating circuits and relay modules  Easy configuration via push buttons and DIP switches on
the front panel
to be added to the system.
 Fully site or field programmable indicating circuits and
Equipped with configuration DIP switches on the main auxiliary relays
display module, the HCP-1000 Series fire alarm control
panels are configured through a combination of DIP  Extensive transient protection
switch and button settings. Through this configuration  Slide-in labels for zone identification
method the user can define the system as a Single
Stage or Two Stage operation as well as perform  6 Amp or 12 Amp power supplies available
various functions such as a One Man Walk Test.  Removable door for easy installation and servicing
 Removable terminal blocks for easy wiring and servicing

PRODUCT LISTINGS

California State
Fire Marshal
7120-0410:0154
S6468

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0067 04/2015
FIRE ALARM CONTROL UNITS - HCP-1000 SERIES

SYSTEM COMPONENTS ADDER HARDWIRE MODULES

HDM-1008 EIGHT INITIATING CIRCUIT MODULE


The HDM-1008 provides 8 Style B (Class B) or 4 Style
D (Class A) initiating circuits configurable for Alarm,
Supervisory or Trouble zones. The HDM-1008 occu-
HMCC-1024-6DS/HMCC-1024-12DS pies one module slot.

The HMCC-1024-6DS main control unit comes complete


with 8 Class B (Style B) or 4 Class A (Style D) initiating
circuits, 4 Class A/B (Style Z/Y) indicating circuits, a
common control and zone identification display board
for up to 24 points and a 6 Amp power supply which
charges 10-24 AH batteries. The HMCC-1024-12DS is
equipped with a 12 Amp power supply which charges
17-40 AH batteries. Both models are expandable with
up to two adder modules of any type. Both models HSGM-1004 FOUR NOTIFICATION APPLIANCE
mount in a HBBX-1024DS back box. CIRCUIT MODULE
The HSGM-1004 provides 4 Style Z/Y (Class A/B)
notification appliance circuits configurable as Silence
Able or Non-Silence Able. Each NAC circuit is rated at
1.7Amps. The HSGM-1004 occupies one module slot.

HMCC-1024-12XTDS
The HMCC-1024-12XTDS main control unit comes HRM-1008 EIGHT RELAY CIRCUIT MODULE
complete with 8 Class B (Style B) or 4 Class A (Style The HRM-1008 provides eight individual configurable
D) initiating circuits, 4 Class A/B (Style Z/Y) indicating relays per module. Each relay provides one Form C
circuits, a common control and zone identification contact rated at 28 VDC @1 Amp (resistive load) as
display board for up to 72 points and a 12 Amp power well as a green LED to indicate that the relay is active.
supply which charges 17-40 AH batteries. It is expand- The HRM-1008 occupies one module slot.
able with up to eight adder modules. The HMCC-1024-
12XTDS mounts in a HBBX-1024DS enclosure.

F0067 04/2015
Page 2 of 4

Hochiki America Corporation HCP-1000 SERIES - FIRE ALARM CONTROL UNITS Specifications subject to change without notice.
FIRE ALARM CONTROL UNITS - HCP-1000 SERIES

HCP-1000 SERIES ENCLOSURES HRA-1000 SERIES REMOTE MULTIPLEX


ANNUNCIATORS

HRAM-1032TZDS MAIN REMOTE LED


ANNUNCIATOR
The HRAM-1032TZDS Main Remote LED Annunciator
HBBX-1024DS provides common annunciator functions and 32 points
of LED annunciation. The HRAM-1032TZDS has
The HBBX-1024DS universal back box houses the
indicators for A.C. On, Common Trouble and Signal
HMCC-1021-6ADS/12ADS and provides space to
Silence and controls for System Reset, Lamp Test, Fire
mount up to 17 AH batteries. The door features the
Drill, Buzzer Silence and Signal Silence. The HRAM-
universal CAT-30 lock and is available in red exterior.
1032TZDS occupies one display position in the HBB-
Dimensions (minus built-in trim ring): 26"H x 14.5"W x
1000 series
4.2"D

HRAM-1016TZDS MAIN REMOTE LED


ANNUNCIATOR
The HRAM-1016TZDS Remote LED Annunciator pro-
vides 16 points of LED annunciation as well as 16
trouble LEDs. The HRAM-1016TZDS has indicators for
A.C. On, Common Trouble and Signal Silence and
controls for System Reset, Lamp Test, Fire Drill,
Buzzer Silence and Signal Silence. The HRAM-
1016TZDS mounts in a HBB-1000 series enclosure.
HBBX-1024XTDS
The HBBX-1024XTDS enclosure supports one HMCC-
1024-12XTDS and up to 18 AH batteries. The enclo-
sure features the universal CAT-30 lock and a remova-
ble door for easy installation and servicing. The
enclosure is available in red exterior. The HFA-XT-TRB
Semi-Flush Trim Ring is required for semi-flush
mounting. HBBX-1024XTDS dimensions: 35 ½”H x 14 HRAX-1048TZDS PROGRAMMABLE LED
½”W x 5 ¼”D ANNUNCIATOR MODULE
The HRAX-1048TZDS Programmable LED Annunciator
DIMENSIONS FOR ANNUNCIATOR MODULE Module provides 48 programmable bi-colored LEDs.
ENCLOSURES The HRAX-1048TZDS connects to the main unit
HRA-1032TZDS when mounted remotely. The HRAX-
Model Dimensions 1048TZDS occupies one display position in the
HBB-1001 9”H x 12.75”W x 1.2”D HBB-1000 series enclosures.
HBB-1002 18”H x 12.75”W x 1.2”D
HBB-1003 26.4”H x 12.75”W x 1.2”D
HBB-1008 33”H x 22.5”W x 1.25”D F0067 04/2015
HBB-1012 45”H x 22.5”W x 1.25”D Page 3 of 4

Hochiki America Corporation HCP-1000 SERIES - FIRE ALARM CONTROL UNITS Specifications subject to change without notice.
FIRE ALARM CONTROL UNITS - HCP-1000 SERIES
ELECTRICAL RATINGS

HMCC-1024-6DS
AC Line Voltage 120V 60Hz / 240V 50 Hz, 2A / 1A primary
Power Supply Ratings 6 Amps. max. (secondary)
For Indicating Circuits 24VDC unfiltered, 5 Amps maximum
Charging Capability 10-24 AH batteries
Current Consumption Standby 200 mA
Current Consumption Alarm 350 mA

HMCC-1024-12DS/HMCC-1024-12XTDS
AC Line Voltage 120V 60Hz / 240V 50 Hz, 2A / 1A primary
Power Supply Ratings 6 Amps. max. (secondary)
For Indicating Circuits 24VDC unfiltered, 10 Amps maximum
Charging Capability 17-40 AH batteries
Current Consumption Standby 200 mA
Current Consumption Alarm 350 mA

ORDERING INFORMATION
MODEL DESCRIPTION
FIRE ALARM CONTROL PANEL
HCP-1008EDS 8 Zone Conventional FACP, expandable to 24 circuit, red, 120/240V
MAIN CONTROL UNIT
HMCC-1024-6DS Main Control Unit, 6 Amps. Mounts in HBBX-1024DS.
HMCC-1024-12DS Main Control Unit, 12 Amps. Mounts in HBBX-1024DS.
HMCC-1024-12XTDS Main Control Unit, 12 Amps. Mounts in HBBX-1024DS.
ADDER MODULES
HDM-1008 Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuit Module
HSGM-1004 Four Class A/B (Style Z/Y) Notification Appliance Circuit Module (Rated at 1.7 Amps per circuit)
HRM-1008 Eight Relay Circuit Module c/w eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay)
ENCLOSURES
HBBX-1024DS Universal Black Back Box.
HBBX-1024XTDS Enclosure for HMCC-1024-12XTDS c/w removable red door, black back box and CAT-30 lock and key.
HFA-XT-TRB Black Semi-Flush Trim Ring for HBBX-1024XTS Enclosure
REMOTE ANNUNCIATORS
HRAM-1032TZDS Main Remote LED Annunciator c/w 32 Bi-Colored LEDs and 32 Trouble LEDS
HRAM-1016TZDS Main Remote LED Annunciator c/w 16 Bi-Colored LEDs and 16 Trouble LEDS
HRAX-1048TZDS Programmable LED Annunciator Module c/w 48 Bi-Colored LEDs and 48 Trouble LEDs
HBB-1001 Remote Enclosure. Houses one module.
HBB-1002 Remote Enclosure. Houses two modules.
HBB-1003 Remote Enclosure. Houses three modules.
HBB-1008 Remote Enclosure. Houses eight modules.
HBB-1012 Remote Enclosure. Houses twelve modules.

F0067 04/2015
Page 4 of 4

Hochiki America Corporation HCP-1000 SERIES - FIRE ALARM CONTROL UNITS Specifications subject to change without notice.
REMOTE MULTIPLEX ANNUNCIATORS - HRA-1000 SERIES

STANDARD FEATURES
 Large capacity of annunciation
 Provides annunciation through three annunciator
chassis modules
 Bi-colored LEDs
 Slide-in labels for each display point
 Surface mount to standard gang outlet boxes
 Sealed membrane-like buttons and LED indicators
DESCRIPTION
 Local Buzzer, Silence and Lamp Test switches
Hochiki’s modular HRA-1000 Series Remote Annuncia-
tors are multiplex annunciator panels that provide a  LEDs for A.C. On, Common Trouble, Remote
large capacity of annunciation with the Hochiki HCP- Failure, Aux. Disconnect, Acknowledge, General
1000 Series Fire Alarm Control Panels. The HRA-1000 Alarm, Signal Silence and Test/Configuration Mode
Series is comprised of three chassis models. The  Controls for System Reset, Lamp Test, Fire Drill,
HRAM-1032TZDS Main Annunciator Chassis consists Aux. Disconnect, Buzzer Silence, Signal Silence,
of sealed membrane-like buttons and LED indicators. General Alarm and Acknowledge
Complete with common control features and indicators,
the HRAM-1032TZDS Main Annunciator Chassis  Each annunciation point is automatically selected for
provides up to 32 points of annunciation and can be either Alarm (red) or Supervisory (amber) to match
expanded with up to four HRAX Adder Annunciator the fire alarm control panel configuration
Chassis Modules. Defined via DIP switches, the
HRA-1000 Remote Annunciators are automatically  Five sizes of enclosures
configured to match the fire alarm control panel
configuration.
The HRAX-1048TZDS Adder Annunciator Chassis has
the same basic construction as the Main Annunciator
Chassis and can provide up to 48 points of
annunciation. It interconnects to either a HRAM-
1032TZDS Main Annunciator or a HRAX-1048TZDS
Adder Annunciator Chassis. Up to four HRAX-
1048TZDS Adder Annunciator Chassis can be
connected to one HRAM-1032TZDS. The annunciators
come standard with bi-colored LEDs to annunciate
alarm or supervisory points. Each display point can be
identified by the slide-in label that slides in beside the
LED. The annunciator modules can mount into five
various sized enclosures.

PRODUCT LISTINGS

California State
Fire Marshal
7120-0410:0157
S5694

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0067A 04/2015
REMOTE MULTIPLEX ANNUNCIATORS - HRA-1000 SERIES

HRAM-1032TZDS MAIN REMOTE LED HRAX-1048TZDS PROGRAMMABLE LED


ANNUNCIATOR ANNUNCIATOR MODULE

The HRAM-1032TZDS Main Remote LED Annunciator The HRAX-1048TZDS Programmable LED Annunciator
provides common annunciator functions and 32 points Module provides 48 programmable bi-colored LEDs.
of LED annunciation. The HRAM-1032TZDS has The HRAX-1048TZDS connects to the main control
indicators for A.C. On, Common Trouble and Signal unit or main annunciator module when mounted
Silence and controls for System Reset, Lamp Test, remotely. Each display point can be identified by the
Fire Drill, Buzzer Silence and Signal Silence. Each slide-in label that slides in besides the LED. The
display point can be identified by the slide-in label that HRA-1048TZDS occupies one display position in the
slides in besides the LED. The HRAM-1032TZDS HBB-1000 series.
allows for the control switches to be disabled on a per
function basis for areas that do not require certain
common control functions to be remotely located from
the fire alarm control unit. The HRAM-1032TZDS can
be expanded with the addition of HRAX-1048TZDS
Programmable LED Annunciator Modules. The HRAM-
1032TZDS occupies one display position in the HBB-
1000 series.

HRAM-1016TZDS MAIN REMOTE LED


ANNUNCIATOR

The HRAM-1016TZDS Main Remote LED Annunciator


provides common annunciator functions and 16 points
of LED annunciation. The HRAM-1016TZDS has
indicators for A.C. On, Common Trouble and Signal
Silence and controls for System Reset, Lamp Test, Fire
Drill, Buzzer Silence and Signal Silence. Each display
point can be identified by the slide-in label that slides in
besides the LED. The HRAM-1016TZDS allows for the
control switches to be disabled on a per function basis
for areas that do not require certain common control
functions to be remotely located from the fire alarm
control unit. The HRAM-1016TZDS is a non-expandable
unit that occupies one display position in the HBB-1000
series.

F0067A 04/2015
Page 2 of 4

Hochiki America Corporation HRA-1000 SERIES - REMOTE MULTIPLEX ANNUNCIATORS Specifications subject to change without notice.
REMOTE MULTIPLEX ANNUNCIATORS - HRA-1000 SERIES
HBB-1001 SEMI-FLUSH ENCLOSURE
The HBB-1001 comes complete with a back box, door and hinge. The
enclosure door comes with a LexanTM window, two keys and a durable
lock. The door comes hinged to the left side of the box. The box is
capable of handling one HRAM-1032TZDS Main Annunciator Chassis
which provides up to 32 points of annunciation.

HBB-1002 SEMI-FLUSH ENCLOSURE


The HBB-1002 comes complete with a back box, door and hinge. The HBB-1001
enclosure door comes with LexanTM windows, two keys and a durable
lock. The door comes hinged to the left side of the box. The enclosure
is capable of handling one HRAM-1032TZDS Main Annunciator
Chassis and one HRAX-1048TZDS Adder Annunciator Chassis.

HBB-1003 SEMI-FLUSH ENCLOSURE


The HBB-1003 comes complete with a back box, door and hinge. The
enclosure door comes with LexanTM windows, two keys and a durable
lock. The door comes hinged to the left side of the box. The enclosure
is capable of handling one HRAM-1032TZDS Main Annunciator
Chassis and two HRAX-1048TZDS Adder Annunciator Chassis.

HBB-1008 SEMI-FLUSH ENCLOSURE HBB-1002


The HBB-1008 comes complete with a back box, door and hinge. The
enclosure door comes with LexanTM windows, two keys and a durable
lock. The door comes hinged to the left side of the box. The enclosure
is capable of handling up to one HRAM-1032TZDS Main Annunciator
Chassis, four HRAX-1048TZDS Adder Annunciator Chassis and three
additional slots for a combination of either fan damper modules, zoned
audio paging modules and zoned fire fighters’ telephone modules.

HBB-1012 SEMI-FLUSH ENCLOSURE


The HBB-1012 comes complete with a back box, door and hinge. The
enclosure door comes with LexanTM windows, two keys and a durable
lock. The door comes hinged to the left side of the box. The enclosure
is capable of handling up to one HRAM-1032TZDS Main Annunciator
Chassis, four HRAX-1048TZDS Adder Annunciator Chassis and seven
additional slots for a combination of either fan damper modules, zoned
audio paging modules and zoned fire fighters’ telephone modules.

HBB-1003

F0067A 04/2015
Page 3 of 4

Hochiki America Corporation HRA-1000 SERIES - REMOTE MULTIPLEX ANNUNCIATORS Specifications subject to change without notice.
REMOTE MULTIPLEX ANNUNCIATORS - HRA-1000 SERIES

DIMENSIONS
HBB-1001 Enclosure: 9”H x 12.75”W x 1.2”D HBB-1008 Enclosure: 33”H x 22.5”W x 1.25”D
HBB-1002 Enclosure: 18”H x 12.75”W x 1.2”D HBB-1012 Enclosure: 45”H x 22.5”W x 1.25”D
HBB-1003 Enclosure: 26.4”H x 12.75”W x 1.2”D

TYPICAL REMOTE ANNUNCIATOR WIRING DIAGRAM

1 Twisted shielded pair for


1communications
Tw iste d S h ie ld e d P a ir fo r T h e H R S -4 8 5 w irin g n e e d s to b e tw iste d sh ie ld e d p a ir.
The HRS-485 wiring needs to be twisted shielded pair.
TEST/CONFIG COMMON COMMON
MODE TROUBLE ALARM

REMOTE COMMON
FAILURE A.C. ON SUPERVISORY

SYSTEM
RESET
LAMP
TEST
BATTE RY
TROUBLE

C o m m u n ic a tio n s T h e w ire g a u g e m a y b e 2 2 AW G u p to 4 0 0 0 ft., 2 0 AW G


The wire gauge may be 22 AWG up to 4000 feet, 20 AWG
GROUND
FAULT

FIRE AUXILIARY
DRILL DISCONNECT SIGNAL

u p to 6 0 0 0 fe e t o r 1 8 AW G u p to 8 0 0 0 ft.
TROUBLE 1

11 UUntwisted unshielded
n sh ie ld e d pair
P a irfor
SIGNAL

n tw iste d U
TROUBLE 2
BUZZER
ACKNOWLEDGE

up to 6000 feet or 18 AWG up to 8000 feet.


SILENCE

SIGNAL
TROUBLE 3

GENERAL SIGNAL
ALARM SILENCE
SIGNAL

24r 2VDC
4 V DPower
TROUBLE 4

fo C Power

T EST /C O N F IG C O MMO N
MO D E T R O U BL E
T EST /C O N F IG C O MMO N
MO D E T R O U BL E

R EM O T E
FAIL U R E A.C . O N
R EM O T E
FAIL U R E A.C . O N

SYST EM L AM P
R ESE T T ES T
SYST EM L AM P
R ESE T T ES T

F IR E AU XIL IA RY
D R ILL D ISC O N N ECT
F IR E AU XIL IA RY
D R ILL D ISC O N N ECT

BU Z Z ER
AC KN O W L ED G E SIL EN C E
BU Z Z ER
AC KN O W L ED G E SIL EN C E

G EN ER AL SIG N AL
AL AR M SIL EN C E
G EN ER AL SIG N AL
AL AR M SIL EN C E

H HRA-1000
R A -1 0 0 0 Series
S e rie s HHRA-1000
R A -1 0 0 0Series
S e rie s
R eRemote
m o te MMultiplex
u ltip le x Annunciator
A n n u n c ia to r R eRemote
m o te M u ltip le xAnnunciator
Multiplex A n n u n c ia to r
(H B B -1 0 0 1 E n c lo s u re ) (H B B -1 0 0 1 E n clo su re )
(HBB-1001 Enclosures) (HBB-1001 Enclosures)
Fire
F ire Alarm
A la Control
rm C o n tro lUnit
U n it

NOTE: Annunciator wiring must be as shown. Star type or “T” tap connections are not allowed.
The HRA-1000 Series Remote Annunciators must be wired in a loop configuration.

ORDERING INFORMATION
MODEL DESCRIPTION
MODULES
HRAX-1016TZDS Main Annunciator Chassis c/w Common Control Features, Indicators and

HRAM-1032TZDS Main Annunciator Chassis c/w Common Control Features, Indicators and

HRAX-1048TZDS Adder Annunciator Chassis c/w 48 Bi-Colored LEDs and 48 Trouble LEDs
BACK BOXES
HBB-1001 Annunciator back box with key lock door (Houses 1 module)
HBB-1002 Annunciator back box with key lock door (Houses 2 module)
HBB-1003 Annunciator back box with key lock door (Houses 3 module)
HBB-1008 Annunciator back box with key lock door (Houses 8 module)
HBB-1012 Annunciator back box with key lock door (Houses 12 module)

F0067A 04/2015
Page 4 of 4

Hochiki America Corporation HRA-1000 SERIES - REMOTE MULTIPLEX ANNUNCIATORS Specifications subject to change without notice.
Series HPS-SAH, HPS-SAK, HPS-DAH, HPS-DAH/S, HPS-DAK, HPS-DAK/S
Manual Non-Coded Pull Station

STANDARD FEATURES

• Metal Construction
• Enclosed switch with glass rod (included)
• 10 Amps @ 120 VAC
• Available in: Single Action, Dual Action and
Dual Action in Spanish (HPS-DAH/S)
• UL, CSFM Listed
• Made in USA

HPS-SAH HPS-SAK
DESCRIPTION

Hochiki America’s Models HPS series pull stations


are available in six models:

• HPS-SAH single action with Hex lock


• HPS-SAK single action with Key lock
• HPS-DAH dual action with Hex lock
• HPS-DAH/S dual action with Hex lock (Spanish)
• HPS-DAK dual action with Key lock
• HPS-DAK/S dual action with Key lock (Spanish)

HPS-DAH HPS-DAH/S Each model is constructed of a solid die cast housing


and comes in glossy red. The back switch plate is
plated steel. The electrical switch is rated for 10 Amps
@ 120 VDC normally open contact rating. All models
are connected via terminal block connections.

PRODUCT LISTINGS

California
State Fire
Marshal

7150-0410:162
S6512

HPS-DAK HPS-DAK/S
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0033 11/2012
Rear View Front View

PULL DOWN

SPECIFICATION

Model SAH, SAK, DAH, DAH/S, DAK, DAK/S EXP./WTP. PRF.


Contact SPST Form "A" DPDT Form "C"
Terminal Block A A&B
Terminal Connecting 2&3 1,2,3,5,6,7
Terminal Connection LED 1 (+) & 4 (-) 4 (+) & 8 (-)
Terminal Connection Switch 1&4 4&8
Terminal Connection Phone Jack 1&4 4&8
Contact Rating 10A @ 120 VAC 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C) -30°F (-35 °C) ~ 150°F (66°C)

ELECTRICAL WIRING

Hochiki America Corporation Series HPS-SAH, HPS-SAK, HPS-DAH, HPS-DAH/S, HPS-DAK, HPS-DAK/S Specifications subject to change without notice.
HPS-SAH-WP Weather Proof Manual Pull Stations
DESCRIPTION
The Hochiki HPS-SAH-WP Weatherproof Manual Pull
Station is a UL Listed fire alarm initiating device
suitable for applications requiring outdoor mounting of
the manual fire alarm pull station. The HPS-SAH-WP
is appropriate for applications where the manual pull
station may be subject to wet conditions.

The HPS-SAH-WP consists of a die-cast aluminum


back box (HPS-BB), Neoprene sealing gasket and a
special manual fire alarm box. The unit is a high
quality pull station constructed entirely of nontoxic
materials with a low profile and rounded edges to fit
most design requirements. All components are pre-
painted, or have plated surfaces to inhibit corrosion.

The latching pull-down lever on the HPS-SAH-WP


requires a hex key to reset it. This allows only
authorized personnel to reset the manual pull station
STANDARD FEATURES so that the origin of the alarm can be determined
easily.
• Weatherproof Manual Pull Station
• 10 A, 120 VAC contacts The HPS-SAH-WP has one set of Normally Open
• Rugged die-cast aluminum housing contacts rated for 10A @ 120 VAC, making the device
• Neoprene sealing gasket suitable for installations involving large current loads.
• Corrosion-resistant construction
• Hex reset The HPS-SAH-WP conforms with the Americans with
• Latching pull-down lever Disabilities Act (ADA).
• Screw terminal connections

SPECIFICATIONS
Model HPS-SAH-WP Pigtails
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)
HPS-BB Dimension 1-3/4" Backbox

PRODUCT LISTINGS

California
State Fire
Marshal

7150-0410:162
S6512

Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0035 02/2014
HPS-DAK-WP Weatherproof Manual Pull Stations
DESCRIPTION
The Hochiki HPS-DAK-WP Weatherproof Manual Pull
Station is a fire alarm initiating device suitable for
applications requiring outdoor mounting of the fire
alarm manual pull station. The HPS-DAK-WP is
appropriate for applications where the manual pull
station may be subject to wet conditions.

The HPS-DAK-WP consists of a die-cast aluminum


back box, Neoprene sealing gasket and a special
manual fire alarm box. The unit is a high quality pull
station constructed entirely of nontoxic materials with
a low profile and rounded edges to fit most design
requirements. All components are pre-painted, or have
plated surfaces to inhibit corrosion.

The latching pull-down lever on the HPS-DAK-WP


requires a key to reset it. This allows only authorized
personnel to reset the manual pull station so that the
STANDARD FEATURES origin of the alarm can be determined easily.
• Weatherproof Manual Pull Station
The HPS-DAK-WP has one set of Normally Open
• 10 A, 120 VAC contacts contacts rated for 10A @ 120 VAC, making the device
• Rugged die-cast aluminum housing and backbox suitable for installations involving large current loads.
• Neoprene sealing gasket
The HPS-DAK-WP conforms with the Americans with
• Corrosion-resistant construction
Disabilities Act (ADA).
• KEY reset
• Lift and Latching pull-down lever
• Enclosed switch with glass rod (Included)
• Screw terminal connections
Pigtails

SPECIFICATIONS
Model HPS-DAK-WP
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)

Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0086 01/2014
HPS-DAK-SR
Manual Pull Station for Fire Suppression Release

SPECIFICATIONS
Model HPS-DAK-SR
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)

STANDARD FEATURES

• Metal Construction
• Enclosed switch with glass rod (included)
• UL, CSFM Listed
• Made in USA

DESCRIPTION

HPS-DAK-SR is a dual action (lift & pull) fire suppres-


sion release manual pull station. HPS-DAK-SR model
ELECTRICAL WIRING is constructed of a solid die cast housing and comes
in glossy red. The back switch plate is plated steel.
The electrical switch is rated for 10 Amps @ 120 VAC
normally open contact rating. All models are con-
nected via terminal block connections.

PRODUCT LISTINGS

California
State Fire
Marshal

7150-0410:162
S6512

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0127 03/2012
HPS-CP CALL POINT BREAK GLASS STATIONS
SPECIFICATIONS
Contacts Normally Open
Contact Current Rating 3A @ 120 VAC
0.1A @ 125 VDC
Dimensions (WxHxD) 3.5" x 5 1/4" x 3/4"

DESCRIPTION

Hochiki America Models HPS-CP series pull stations


are available in two models:
• HPS-CP call point/break glass
• HPS-CP/S call point/break glass (Spanish)

The Hochiki HPS-CP series is very dependable break


HPS-CP glass station intended for simple yet failsafe operation.
The actuating switch is a heavy duty plunger type, with
a Glass plate covering (2.5" x 2.5") which is a
Factrolite single strength (obscured) type. Design of
this station is such that it seems to inhibit the "false
alarm" factor that is so prevalent in public schools and
places of public assembly. The steel rod attached to
the station is not necessary to break the glass. A
slight blow of the hand, coin, key, pencil, etc. is
sufficient to break the glass and initiate the alarm.
The HPS-CP is intended for mounting in a standard
electrical outlet box.

WIRING DIAGRAM
TOP REAR VIEW

HPS-CP/S
L1
IN INITIATING
L2
CIRCUIT
STANDARD FEATURES L2 OUT
L1

• Actuating switch, a heavy duty plunger type


• Glass plate (2.5" x 2.5"), a Factrolite single
strength (obscured) type. PRODUCT LISTINGS
• Steel rod attached
• Mounts in a standard electrical outlet box
• Available in English & Spanish California
State Fire
• UL listed Marshal
• Made in USA
7150-0410:164
S6512
Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0059 09/2013
HPS-SA-EX/WP Explosion Proof Manual Pull Stations
DESCRIPTION

The Hochiki HPS-SA-EX/WP Explosion Proof Manual


Pull Station is a single action, UL listed fire alarm
initiating device. With a UL rating of class I groups B
(hydrogen), C and D; class II groups E, F and G; class
III and an outdoor rating of type 4X, this station offers
unmatched placement flexibility. The 2 sets of Form
"C" (NO/C/NC) contacts are rated for 10 Amps at 120/
240 VAC. The HPS-SA-EX/WP has an easily identifi-
able pull down lever and contains an integral break
glass rod carrier.

The unit is a high quality manual fire alarm box con-


structed entirely of a high strength metal die-cast alloy
with a low profile and rounded edges to fit most design
applications. All components are prepainted or have
STANDARD FEATURES plated surfaces to inhibit corrosion. Non-corroding
screw terminals are provided for wire connections to
• Compatible with all Hochiki Control Panels the HPS-SA-EX/WP.
• Rugged die-cast housing The HPS-SA-EX/WP is manufactured in conformance
• UL rated class I group B (hydrogen) C&D, with the standards set forth in the Americans with
class II groups E,F,G, class III, NEMA 4X Disabilities Act (ADA).
• Weather Proof
• Corrosion-resistant construction The HPS-SA-EX/WP has a white pull down lever in its
center. Pulling down the lever latches it into place.
• Latching alarm levers
The HPS-SA-EX/WP's normally open contact switch is
• Screw Terminals 12-22 AWG shorted causing an alarm on the fire initiating loop.
• Key-locked reset The pull down lever can not be reset unless the correct
key is inserted into the manual fire alarm box lock and
• Optional glass break rod
the unit is opened. The latching lever can then be
• DPDT Contacts restored to its normal position.

When the HPS-SA-EX/WP is being reset and has a


SPECIFICATIONS glass break rod installed, all debris must be removed
Model HPS-SA-EX/WP prior to installing another rod to ensure the unit will
Contact DPDT Form "C" (NO/C/NC) close and lock securely.
Contact Rating 10A @ 120/240 VAC
0.5A @ 30 VDC PRODUCT LISTINGS
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)
Maximum Humidity 90% RH, non-condensing California
Dimensions 4.75" x 3.125" x 3.375" State Fire
(12.1cm x 7.9cm x 8.6cm)
Number of Knockouts 2 x 3/4" (Top & Bottom)
7151-0410:163
Specifications subject to change without notice E236171

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0034 03/2014
SLR-24V PHOTOELECTRIC SMOKE DETECTOR
APPLICATION
The SLR-24V can be used in all areas where Photoelec-
tric Smoke Detectors are required. The wide range
smoke chamber makes the SLR-24V well suited for fires
ranging from smoldering to flaming fires.
NS-4 Series, NS-6 Series, HSC-4R or HSC-xxx R Style
bases may be used with the SLR-24V. Current
interchangeable/compatible devices are the SIJ-24
ionization detector, the SLR-24H photoelectric detector
with heat sensor, and the DCD-135/190 heat detectors.
All NS conventional devices are mechanically
compatible with Hochiki America HSB, HSC and YBA
Shown without base. type bases which may have been used in previous
installations. Please check individual panel listings for
STANDARD FEATURES compatible bases.
• Low profile, 1.8" high (with base)
• 2 or 4 wire base compatibility, relay bases available OPERATION
• Highly stable operation, RF/Transient protection The SLR-24V photoelectric smoke detector utilizes two
• Low standby current, 45μA at 24VDC bicolored LEDs for indication of status. In a normal
• Two built-in power/sensitivity supervision/alarm LEDs standby condition the LEDs flash Green every 3 sec-
• Non-directional smoke chamber onds. When the detector senses that its sensitivity has
• Vandal resistant security locking feature drifted outside the UL listed sensitivity window the LEDs
• Built-in magnetic go/no go detector test feature will flash Red every 3 seconds. When the detector
• Removable smoke labyrinth for cleaning or senses smoke and goes into alarm the status LEDs will
replacement
latch on Red.
• Automatic Sensitivity window verification function
meets outlined requirements in NFPA 72, Chapter 2 The detector utilizes an infrared LED light source and
& 7, Inspection, Testing and Maintenance silicon photo diode receiving element in the smoke cham-
• Compatible with SIJ-24 ionization detectors ber. In a normal standby condition, the receiving ele-
• Backwards compatible with Hochiki SLK and SIH ment receives no light from the pulsing LED light source.
detectors In the event of a fire, smoke enters the detector smoke
chamber and light is reflected from the smoke particles
SPECIFICATIONS
to the receiving element. The light received is converted
Light Source GaAlAs Infrared into an electronic signal.
Emitting Diode
Rated Voltage 17.7 - 30.0 VDC Signals are processed and compared to a reference level,
and when two consecutive signals exceeding the refer-
Working Voltage 15.0 - 33.0 VDC
ence level are received within a specified period of time,
Maximum Voltage 42 VDC the time delay circuit triggers the SCR switch to activate
Supervisory Current 45μA @ 24 VDC the alarm signal. The status LEDs light continuously
Surge Current 160μA max. @ 24VDC during the alarm period.
Alarm Current 150mA max. @ 24 VDC
Air Velocity Range 0-4000 fpm PRODUCT LISTINGS
Maximum Humidity 95% RH Non-Condensing
Ambient Temperature 32°F to 120°F (0°C to 49°C) California
Color & Case Material Bone PC/ABS Blend State Fire
Sensitivity Test Feature Automatic Sensitivity 1D5A1.AY Marshal
window verification test 7272-0410:107
Mounting Refer to NS Conventional S1383
Detector Base Data Sheet Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0017 01/2014
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, Hochiki America Model SLR-24V photoelectric smoke detectors.
The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel.
The base shall permit direct interchange with Hochiki America SLR-24H combination photoelectric/heat detector, SIJ-24 ionization
type smoke detector and/or DCD-135/190 fixed temperature/rate-of-rise heat detectors. The base shall be appropriate twist-lock base
NS-4 Series, NS-6 Series, HSC-4R, or HSC-xxx R. In the event of partial or complete retrofit, the SLR-24V maybe used in conjunction
with, or as a replacement for, Hochiki America detectors (SLK-24, SLK-24FH and the SIH-24) on most HSB and HSC base applica-
tions.
The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby condition the LEDs
will flash Green. When the detector is outside the UL listed sensitivity window the LEDs will flash Red. When the detector is
actuated, the flashing LEDs will latch on Red. The detector may be reset by actuating the control panel reset switch.
The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the detector
without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and continuously to verify that
it is operating within the listed sensitivity range.
To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed to
minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated.

SLR-24V SENSITIVITY TEST FEATURE


The SLR-24V Photoelectric Smoke Detector has a built-in automatic sensitivity test feature.
1. In normal condition, both LED's flash green.
2. When the sensitivity drifts outside of its sensitivity limits, both LED's flash red.
3. In the alarm state both LED's are red continuously.
4. When the sensitivity drifts outside of its sensitivity limits and both LED's flash red, the device needs to be cleaned or returned
to the factory for cleaning. Refer to HA Technical Bulletin HA-97 for cleaning information.

2-WIRE OPERATION
UL LISTED
CONTROL LISTED
PANEL END OF LINE
DEVICE

PANEL Resistor shown is for


example only. Not all
POWER annunciators have in
SUPPLY line resistance.
NOTE: - WIRING TERMINALS FOR THE NS4
NEGATIVE AND NS6 ARE IDENTICAL
NS4 SERIES NS6 SERIES - BASES WITH THE "W" SUFFIX
Annunciation device must be current limited to 20 mA @ ARE WHITE IN COLOR
24VDC Maximum. Not limiting current could result in
damage to the detector or cause a no alarm condition.

2-WIRE RELAY OPERATION


UL LISTED LISTED
CONTROL END OF LINE
PANEL
DEVICE
TERMINAL BLOCK USED ON
HSC-224RA/RST VERSION ONLY
HSC-(XXX)R (2-WIRE)
COM 6
GRY
N/C 5 BLU
GRN
N/O 4 YEL

HSC-RELAY SERIES
ORN
N/O 3 PUR

N/C 2 2 AND 4 WIRE BASE


RELAYS SHOWN WITH
1 POWER OFF.
4-WIRE OPERATION
COM

INITIATING LISTED
CIRCUIT END OF LINE
DEVICE
HSC-4R
CONTACTS
H1
H2
YEL
ORN
PUR

UL LISTED LISTED
POWER END OF LINE
SUPPLY RELAY
12VDC OR 24VDC HA-EOLR-12 OR HA-EOLR-24

HSC-4R HSC-4R
Hochiki America Corporation SLR-24V Specifications subject to change without notice.
SLR-24VN PHOTOELECTRIC SMOKE DETECTOR
APPLICATIONS
The SLR-24VN can be used in all areas where Photo-
electric Smoke Detectors are required. The wide range
smoke chamber makes the SLR-24VN (w/o Reed Switch
model) well suited for fires ranging from smoldering to
flaming fires.

NS-4 Series, NS-6 Series, HSC-4R or HSC-R Style


bases may be used with the SLR-24VN. Current inter-
changeable/compatible devices are the SIJ-24 ioniza-
tion detector, the SLR-24H photoelectric detector with
heat sensor, and the DCD-135°/190° heat detectors.

All NS conventional devices are mechanically compat-


Shown without base.
ible with Hochiki America HSB, HSC and YBA type
STANDARD FEATURES bases which may have been used in previous installa-
• Low profile, 1.8" high (with base) tions. Please check individual panel listings for com-
• 2 or 4 wire base compatibility, relay bases available
• Highly stable operation, RF/Transient protection OPERATION
• Low standby current, 45μA at 24VDC The SLR-24VN photoelectric smoke detector utilizes two
• Two built-in power/sensitivity supervision/alarm
LEDs bicolored LEDs for indication of status. In a normal
• Non-directional smoke chamber standby condition the LEDs flash Green every 3 sec-
• Removable smoke labyrinth for cleaning or onds. When the detector senses that its sensitivity has
replacement drifted outside the UL listed sensitivity window the LEDs
• Automatic Sensitivity window verification function will flash Red every 3 seconds. When the detector
meets outlined requirements in NFPA 72,Chapter 2 senses smoke and goes into alarm the status LEDs will
& 7, Inspection, Testing and Maintenance. latch on Red.
• Compatible with SIJ-24 ionization detectors
• Backwards compatible with Hochiki SLK and The detector utilizes an infrared LED light source and
SIH detectors silicon photo diode receiving element in the smoke cham-
SPECIFICATIONS ber. In a normal standby condition, the receiving ele-
ment receives no light from the pulsing LED light source.
Light Source GaAlAs Infrared
In the event of a fire, smoke enters the detector smoke
Emitting Diode
chamber and light is reflected from the smoke particles
Rated Voltage 17.7 - 30.0 VDC
to the receiving element. The light received is converted
Working Voltage 15.0 - 33.0 VDC
into an electronic signal.
Maximum Voltage 42 VDC
Supervisory Current 45μA @ 24 VDC
Signals are processed and compared to a reference level,
Surge Current 160μA max. @ 24VDC
and when two consecutive signals exceeding the refer-
Alarm Current 150mA max. @ 24 VDC ence level are received within a specified period of time,
Air Velocity Range 0-4000 fpm
the time delay circuit triggers the SCR switch to activate
Maximum Humidity 95% RH Non-Condensing
the alarm signal. The status LEDs light continuously
Ambient Temperature 32°F to 120°F (0°C to 49°C) during the alarm period.
Color & Case Material Bone PC/ABS Blend
Sensitivity Test Feature Automatic Sensitivity PRODUCT LISTINGS
window verification test
Mounting Refer to NS Conventional California
Detector Base Data Sheet State Fire
Marshal
7272-0410:107
Specification subject to change without notice S1383

Hochiki America Corporation Continued on back.


7051 Village Drive, Suite 100 • Buena Park, CA 90621-2268
Phone: 714/522-2246 • Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0130 07/2014
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, Hochiki America Model SLR-24VN photoelectric smoke
detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel.
The base shall permit direct interchange with Hochiki America SLR-24H combination photoelectric/heat detector, SIJ-24 ioniza-
tion type smoke detector and/or DCD-135°/190° fixed temperature/rate-of-rise heat detectors. The base shall be appropriate
twist-lock base NS-4 Series, NS-6 Series, HSC-4R, or HSC-R. In the event of partial or complete retrofit, the SLR-24VN maybe
used in conjunction with, or as a replacement for, Hochiki America detectors (SLK-24, SLK-24FH and the SIH-24) on most HSB
and HSC base applications.

The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby condition the
LEDs will flash Green. When the detector is outside the UL listed sensitivity window the LEDs will flash Red. When the detector
is actuated, the flashing LEDs will latch on Red. The detector may be reset by actuating the control panel reset switch.
The sensitivity of the detector shall be capable of being measured. The sensitivity of the detector shall be monitored automati-
cally and continuously to verify that it is operating within the listed sensitivity range.
To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed
to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated.

SLR-24VN SENSITIVITY TEST FEATURE


The SLR-24VN Photoelectric Smoke Detector has a built-in automatic sensitivity test feature.
1. In normal condition, both LED's flash green.
2. When the sensitivity drifts outside of its sensitivity limits, both LED's flash red.
3. In the alarm state both LED's are red continuously.
4. When the sensitivity drifts outside of its sensitivity limits and both LED's flash red, the device needs to be cleaned or
returned to the factory for cleaning or calibration. Refer to HA Technical Bulletin HA-97 for cleaning information.

Hochiki America Corporation • SLR-24VN Specifications subject to change without notice.


SLR-24H PHOTOELECTRIC/ HEAT SMOKE DETECTOR
APPLICATION
The SLR-24H can be used in all areas where Photoelectric
Smoke Detectors are required. The wide range smoke
chamber makes the SLR-24H well suited for fires ranging
from smoldering to flaming fires.

NS-4 Series, NS-6 Series, HSC-4R or HSC-xxx R Style


bases may be used with the SLR-24H. Current
interchangeable/compatible devices are the SIJ-24
ionization detector, SLR-24V photoelectric detector and
the DCD-135/190 heat detectors.

All NS conventional devices are mechanically compatible


with Hochiki America HSB, HSC and YBA type bases
which may have been used in previous installations.
Shown without base. Please check individual panel listings for compatible
bases.
STANDARD FEATURES
• Low profile, 2.2" high (with base)
OPERATION
• 2 or 4 wire base compatibility, relay bases available
• 135°F Fixed Temperature heat sensor (Latching) The SLR-24H photoelectric smoke detector utilizes two
• Heat sensor protected by a built-in guard bicolored LED's for indication of status. In a normal
standby condition the LED's flash Green every 3
• Highly stable operation, RF/Transient protection
seconds. When the detector senses that its sensitivity
• Low standby current, 45μA at 24VDC has drifted outside the UL listed sensitivity window the
• Two built-in power/sensitivity supervision/alarm LED's LED's will flash Red every 3 seconds. When the detector
• Non-directional smoke chamber senses smoke and goes into alarm the status LED's will
• Vandal resistant security locking feature latch on Red.
• Removable smoke labyrinth for cleaning or replacement
• Automatic Sensitivity window verification function The detector utilizes an infrared LED light source and
meets outlined requirements in NFPA 72, Chapter 2 & 7, silicon photo diode receiving element in the smoke
Inspection, Testing and Maintenance chamber. In a normal standby condition, the receiving
element receives no light from the pulsing LED light
SPECIFICATIONS source. In the event of a fire, smoke enters the detector
Light Source GaAlAs Infrared smoke chamber and light is reflected from the smoke
Emitting Diode particles to the receiving element. The light received is
Rated Voltage 17.7 - 30.0 VDC converted into an electronic signal.
Working Voltage 15.0 - 33.0 VDC
Signals are processed and compared to a reference level,
Maximum Voltage 42 VDC
and when two consecutive signals exceeding the
Heat Sensor 135°F reference level are received within a specified period of
Supervisory Current 45μA @ 24 VDC time, the time delay circuit triggers the SCR switch to
Surge Current 160μA max. @ 24VDC activate the alarm signal. The status LED's light
Alarm Current 150mA max. @ 24 VDC continuously during the alarm period.
Air Velocity Range 0-4000 fpm
Maximum Humidity 95% RH Non-Condensing PRODUCT LISTINGS
Ambient Temperature 32°F to 120°F (0°C to 49°C)
Color & Case Material Bone PC/ABS Blend California
Sensitivity Test Feature Automatic Sensitivity State Fire
window verification test 3006185 Marshal
Mounting Refer to NS Conventional 7272-0410:107
Detector Base Data Sheet S1383
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0015 07/2014
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, Hochiki America Model SLR-24H photoelectric
smoke detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire
alarm panel.

The base shall permit direct interchange with Hochiki America SLR-24V photoelectric detector, SIJ-24 ionization type
smoke detector and/or DCD-135/190 fixed temperature/rate-of-rise heat detectors. The base shall be appropriate twist-
lock base NS-4 Series, NS-6 Series, HSC-4R, or HSC-xxx R. In the event of partial or complete retrofit, the SLR-24
maybe used in conjunction with, or as a replacement for, Hochiki America detectors (SLK-24, SLK-24FH and the SIH-
24) on most HSB and HSC base applications.

The smoke detector shall have two flashing status LED's for visual supervision. When the detector is in standby
condition the LED's will flash Green. When the detector is outside the UL listed sensitivity window the LED's will flash
Red. When the detector is actuated, the flashing LED's will latch on Red. The detector may be reset by actuating the
control panel reset switch.

The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the
detector without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and
continuously to verify that it is operating within the listed sensitivity range.

To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be
employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field removable when not required.

SLR-24H SENSITIVITY TEST FEATURE


The SLR-24H Photoelectric Smoke Detector has a built-in automatic sensitivity test feature.
1. In normal condition, both LED's flash green.
2. When the sensitivity drifts outside of its sensitivity limits, both LED's flash red.
3. In the alarm state both LED's are red continuously.
4. When the sensitivity drifts outside of its sensitivity limits and both LED's flash red, the device needs to be
cleaned or returned to the factory for cleaning. Refer to HA Technical Bulletin HA-97 for cleaning information.

(+) 4-WIRE OPERATION


INITIATING LISTED
CIRCUIT END OF LINE
DEVICE
HSC-4R
CONTACTS
(-) H1
H2
YEL
ORN
PUR

UL LISTED (+) LISTED


POWER END OF LINE
SUPPLY RELAY
12VDC OR 24VDC
(-)

HSC-4R HSC-4R

2-WIRE OPERATION
UL LISTED (+)
CONTROL LISTED
PANEL END OF LINE
DEVICE
(-)
PANEL Resistor shown is for example
POWER only. Not all annunciators have
in line resistance.
SUPPLY
(-) NOTE: - WIRING TERMINALS FOR THE NS4
NEGATIVE AND NS6 ARE IDENTICAL
NS4 SERIES NS6 SERIES - BASES WITH THE "W" SUFFIX
Annunciation device must be current limited to 20 mA @ ARE WHITE IN COLOR
24VDC Maximum. Not limiting current could result in
damage to the detector or cause a no alarm condition.

2-wire relay wiring diagram is also available


Hochiki America Corporation SLR-24H Specifications subject to change without notice.
SLR-835/SLR-835H PHOTOELECTRIC SMOKE DETECTOR

SPECIFICATIONS
Light Source GaAIAS infrared LED
Operating Voltage 12 or 24 VDC Nominal
Working Voltage 8 ~ 35 VDC
Wave Form Filtered DC 15% Ripple Max.
Supervisory Current 38µA @ 12 VDC
Consumption 55µA @ 24 VDC
70µA @ 35 VDC
SLR-835 SLR-835H Surge Current 200µA @ 24 VDC Max.
Shown without a base
Alarm Current 150µA Max.
STANDARD FEATURES Sensitivity 1.5 – 3.5%/FT
Heat Sensor 135°F (835H only)
• Low Profile - Only 1.8" high (2.2" 835H)
Compatibility Identifier HD-3
• 2 or 4 wire base compatibility, relay bases available
• 135°F latching heat sensor (835H only) Color & Material Bone / White PC / ABS
Blend
• Heat sensor protected by a built-in guard (835H only)
• Highly stable operation, RF/Transient protection Maximum Humidity 95% RH Non-condensing
• Low standby current Operating Temperature 32°F (0°C) ~ 120°F (49°C)
• Two built-in power/sensitivity supervision/alarm LEDs Dimensions 1.8”H x 3.9”W - SLR-835
• Non-directional smoke chamber 2.2”H x 3.9”W - SLR-835H
• Vandal resistant security locking feature
Mounting Refer to NS Conventional
• Removable smoke labyrinth for cleaning or replacement
detector base datasheet
• Backwards compatible with Hochiki SLK and SIH
detectors
• Automatic Sensitivity window verification function meets OPERATION
outline requirements in the NFPA 72 Inspection Testing
and Maintenance, Chapter 7 The SLR-835/-835H Photoelectric Smoke Detector utilizes
two bicolored LEDs for indication of status. In a normal
standby condition the LEDs flash green every 3 seconds.
APPLICATION When the detector senses that its sensitivity has drifted
The HOCHIKI America SLR-835/-835H can be used in all outside the UL listed sensitivity window the LEDs will flash
areas where photoelectric smoke detectors are required. It is Red every 3 seconds. When the detector senses smoke
suited for fires ranging from smoldering to flaming fires. and goes into alarm the status LEDs will latch on Red.
NS4 Series, NS6 Series, HSC-4R or HSC-(X)R Style bases The detector utilizes an infrared LED light source and silicon
may be used with the SLR-835/-835H. photo diode receiving element in the smoke chamber. In a
normal standby condition, the receiving element receives
no light from the pulsing LED light source. In the event of a
fire, smoke enters the detector smoke chamber and light is
reflected from the smoke particles to the receiving element.
The light received is converted into an electronic signal.
Signals are processed and compared to a reference level,
and when two consecutive signals exceeding the reference
PRODUCT LISTINGS level are received within a specified period of time, the time
delay circuit triggers the SCR switch to activate the alarm
California signal. The status LEDs light continuously during the alarm
State Fire period.
3007144 Marshal
7272-0410:107
S1383

Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0024 09/2014
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, Hochiki America Model SLR-835 Photoelectric smoke
detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel.
When the supply power is 24VDC, the base shall permit direct interchange with Hochiki America SLR-24H combination
photoelectric/heat detector, SLR-24 photoelectric smoke detector, SIJ-24 ionization type smoke detector and DCD-135/190heat
detector.
The base shall be the appropriate twist-lock base NS4 Series, NS6 Series, HSC-4R, or HSC-(X)R Series. In the event of partial
or complete retrofit, the SLR-835, SLR-835H may be used in conjunction with, or as a replacement for, Hochiki America
detectors ( SLK-835H, SLK-24F, SLK-24FH and the SIH-24F) on most HSB and HSC base application.
The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby condition the
LEDs will flash Green. When the detector is outside the UL listed sensitivity window the LEDs will flash Red. When the detector
is actuated, the flashing LEDs will latch on Red. The detector may be reset by actuating the control panel reset switch.
The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the detector
without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and continuously to verify
that it is operating within the listed sensitivity range.
To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be
employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated on the drawing. The
locking feature shall be field removable when not required.

SLR-835/-835H SENSITIVITY TEST FEATURE


The SLR-835/-835H Photoelectric Smoke Detector has a built-in automatic sensitivity test feature.
1. In normal condition, both LEDs flash Green.
2. When the sensitivity drifts outside of its sensitivity limits, both LEDs flash Red.
3. In the alarm state both LEDs are Red continuously.
4. When the sensitivity drifts outside of its sensitivity limits and both LED's flash Red, the device needs to be cleaned or
returned to the factory for cleaning. Refer to HA Technical Bulletin HA-97 for cleaning information.

4-WIRE OPERATION
INITIATING LISTED
CIRCUIT END OF LINE
DEVICE
HSC-4R
CONTACTS
H1
H2

YEL
ORN
PUR
UL LISTED
POWER
SUPPLY LISTED
24VDC END OF LINE
RELAY
HA-EOLR-24

HSC-4R HSC-4R
2-WIRE OPERATION
UL LISTED
CONTROL LISTED
PANEL END OF LINE
DEVICE

PANEL Resistor shown is for example


POWER only. Not all annunciators have
in line resistance.
SUPPLY

NEGATIVE NS4 SERIES


NS6 SERIES
Annunciation device must be current limited to 20 mA @ NOTE: - WIRING TERMINALS FOR THE NS4
24VDC Maximum. Not limiting current could result in AND NS6 ARE IDENTICAL
damage to the detector or cause a no alarm condition. BASES WITH THE "W" SUFFIX
ARE WHITE IN COLOR

2-WIRE RELAY OPERATION


UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
TERMINAL BLOCK USED ON

HSC-(XXX)R (2-WIRE)
COM 6
N/C 5 GRY
BLU
GRN
N/O 4 YEL
ORN
HSC-RELAY SERIES N/O 3 PUR

N/C 2 2 AND 4 WIRE BASE


RELAYS SHOWN WITH
COM 1 POWER OFF.

Hochiki America Corporation SLR-835 Specifications subject to change without notice.


SLR-835B DIRECT-WIRE PHOTOELECTRIC
SMOKE DETECTOR
STANDARD FEATURES
• Low Profile - Only 2.0" High
• 2 or 4 Wire Models
• Highly Stable Operation, RF/Transient Protection
• Two built-in power/sensitivity supervision/alarm LED's
• Non-Directional Smoke Chamber
• Vandal Resistant Security Locking Feature
• Removable smoke labyrinth for cleaning or
replacement
• Automatic Sensitivity window verification function
meets outlined requirements in NFPA 72,
Inspection,Testing and Maintenance
Shown with Trim Ring
APPLICATION
The HOCHIKI America SLR-835B Series can be used in
SPECIFICATIONS all areas where Photoelectric Smoke Detectors are re-
Light Source GaAl AS infrared L.E.D.
Operating Voltage Nominal 12 VDC or 24 VDC quired. It is suited for smoldering or flaming fires.
Working Voltage 8.0-35.0 VDC
Wave Form Filtered DC 15% Ripple Max OPERATION
Supervisory Current 38μA AVG @12 VDC The SLR-835B Series photoelectric smoke detector
55μA AVG @24 VDC
70μA AVG @35 VDC
utilizes two bicolored LED's for indication of status. In
Surge Current 200μA Max @24 VDC a normal standby condition the LED's flash Green every
Alarm Current 150mA Max 3 seconds. When the detector senses that its sensitivity
Ambient Temperature 32° F - 120° F (0°C - 49°C) has drifted outside the UL listed sensitivity window the
Compatibility Identifier HD-6 LED's will flash Red every 3 seconds. When the detector
Maximum Humidity 95% RH Non-Condensing senses smoke and goes into alarm the status LED's
Color & Case Material Bone/White PC/ABS Blend
will latch on Red.
Sensitivity Test Feature Automatic Sensitivity
window verification Test
Ordering Codes The unit is comprised of an LED light source and silicon
2 Wire Detector & Trim Ring photo diode receiving element. In a normal standby
White SLR-835B-2W condition, the receiving element receives no light from
Bone SLR-835B-2 pulsing light source. In the event of fire, smoke enters
4 Wire Detector & Trim Ring
the detector and light is reflected from the smoke
White SLR-835B-4W
Bone SLR-835B-4 particles to the receiving element. The light received is
Dimensions 1.8" (2.2" 835H) H x 3.94" W converted to an electronic signal. Signals are processed
Mounting Refer to NS Conventional
Detector Base Data Sheet
PRODUCT LISTINGS

California
State Fire
3007144 Marshal
7272-0410:107
S1383
Specifications subject to change without notice.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0026 07/2014
OPERATION, continued
in the comparator, and when two consecutive signals exceeding the basic level are received within a specific period of
time, the time delay circuit triggers the SCR switch to activate the alarm signal. The status LED lights continuously
during alarm period.

ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans HOCHIKI America SLR-835B direct-wire photoelectric
smoke detectors. The detector shall be UL listed compatible (2-wire model) with a UL listed fire alarm panel.

The smoke detector shall have green flashing status LED's for visual supervision. When the detector is actuated, the
flashing LED's will turn red and latch on steady. The detector may be reset by actuating the control panel reset switch.

The detector shall have a sensitivity window verification feature. If the sensitivity of the detector drifts outside its
approved window the LED's will flash red to indicate an out of sensitivity condition.

The vandal resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field selectable.

It shall be possible to perform a functional test of the detector without the need of generating smoke. The method shall
simulate effects of products of combustion in the chamber to ensure testing of detector circuits.

Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential.

WIRING DIAGRAMS
2-Wire Wiring Diagram

U.L. Listed Listed


Compatible End-of-Line
Control Device
Panel

4-Wire Wiring Diagram

U.L. Listed Listed


Control End-of-Line
Device
Panel

U.L. Listed
Power
Supply
*24VDC Listed
End-of-Line
Relay
12 or 24VDC
U.L. Listed
Power
Supply
*12VDC
* Use either 12 OR 24VDC . They cannot be used simultaneously.

Hochiki America Corporation SLR-835B Specifications subject to change without notice.


SLR-835BH DIRECT-WIRE PHOTOELECTRIC
HEAT SMOKE DETECTOR
STANDARD FEATURES
• Low Profile - Only 2.375" High.
• 2 or 4 Wire Models
• 135° F Latching Heat Sensor
• Highly Stable Operation, RF/Transient Protection
• Two built-in power/sensitivity supervision/alarm LED's
• Non-Directional Smoke Chamber
• Vandal Resistant Security Locking Feature
• Removable smoke labyrinth for cleaning or
replacement
• Automatic Sensitivity window verification function
meets outlined requirements in NFPA 72,
Inspection,Testing and Maintenance.
Shown With Trim Ring
DESCRIPTION
SPECIFICATIONS The SLR-835BH Series photoelectric smoke detector
Light Source GaAl AS infrared L.E.D. utilizes two bicolored LEDs for indication of status. In a
Operating Voltage Nominal 12 VDC or 24 VDC normal standby condition the LEDs flash Green every 3
Working Voltage 8.0-35.0 VDC
seconds. When the detector senses that its sensitivity
Wave Form Filtered DC 15% Ripple Max
Heat Sensor 135° F (835H only) has drifted outside the UL listed sensitivity window the
Supervisory Current 38μA AVG @12 VDC LEDs will flash Red every 3 seconds. When the detector
55μA AVG @24 VDC senses smoke and goes into alarm the status LEDs
70μA AVG @35 VDC will latch on Red.
Surge Current 200μA Max @24 VDC
Alarm Current 150mA Max The unit is comprised of an LED light source and silicon
Ambient Temperature 32° F - 120° F (0°C - 49°C) photo diode receiving element. In a normal standby
Compatibility Identifier HD-6 condition, the receiving element receives no light from
Maximum Humidity 95% RH Non-Condensing pulsing light source. In the event of fire, smoke enters
Color & Case Material Bone/White PC/ABS Blend the detector and light is reflected from the smoke
Sensitivity Test Feature Automatic Sensitivity
particles to the receiving element. The light received is
window verification Test
Ordering Codes converted to an electronic signal. Signals are processed
2 Wire Detector & Trim Ring in the comparator, and when two consecutive signals
White SLR-835BH-2W exceeding the basic level are received within a specific
Bone SLR-835BH-2 period of time, the time delay circuit triggers the SCR
4 Wire Detector & Trim Ring switch to activate the alarm signal. The Status LED
White SLR-835BH-4W
lights continuously during alarm period.
Bone SLR-835BH-4
Dimensions 1.8" (2.2" 835H) H x 3.94" W PRODUCT LISTINGS
Mounting Refer to NS Conventional
Detector Base Data Sheet
California
State Fire
3012444 Marshal
7272-0410:107
S1383
Specifications subject to change without notice.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0019 07/2014
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans HOCHIKI America SLR-835BH baseless photoelectric
smoke detectors. The combination detector head shall be UL listed compatible with an UL listed fire alarm panel.

The smoke detector shall have flashing status LED for visual supervision. When the detector is actuated, the flashing
LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch.

The detector shall have a sensitivity window verification feature.

The vandal resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field selectable.

It shall be possible to perform a functional test of the detector without the need of generating smoke. The method shall
simulate effects of products of combustion in the chamber to ensure testing of detector circuits.

Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential.

WIRING DIAGRAMS

2-Wire Wiring Diagram

U.L. Listed Listed


Compatible End-of-Line
Control Device
Panel

4-Wire Wiring Diagram

U.L. Listed Listed


Control End-of-Line
Device
Panel

U.L. Listed
Power 24VDC 12VDC C NO 24VDC 12VDC C NO

Supply
*24VDC Listed
End-of-Line
Relay
12 or 24VDC
U.L. Listed
Power
Supply
*12VDC
* Use either 12 OR 24VDC . They cannot be used simultaneously.

Hochiki America Corporation SLR-835BH Specifications subject to change without notice.


SLV-24M MARINE PHOTOELECTRIC SMOKE DETECTOR

APPLICATION
The SLV-24M is for use in enclosed spaces, for
ceiling-mount installations only and for use in
enclosed dry cabin locations, where the unit is
protected against blowing, spraying, and dripping
water. The patented smoke chamber makes the
SLV-24M well suited for fires ranging from smoldering
to flaming fires.
NS4-220 (Marine Type) and NS6-220 (Marine Type)
bases are used with the SLV-24M.

Shown without base


OPERATION
STANDARD FEATURES The SLV-24M photoelectric smoke detector utilizes two
bicolored LEDs for indication of status. In a normal
• Low profile, 2.0" high (with base) standby condition the LEDs flash Green every 3
• Highly stable operation, RF/Transient protection seconds. When the detector senses smoke and goes
• Low standby current, 45μA at 24VDC into alarm the status LEDs will latch on Red.
• Two built-in power/alarm LEDs The detector utilizes an infrared LED light source and
• Non-directional smoke chamber silicon photo diode receiving element in the smoke
• Built-in magnetic go/no go detector test feature chamber. In a normal standby condition, the receiving
• Removable smoke labyrinth for cleaning or element receives no light from the pulsing LED light
replacement source. In the event of a fire, smoke enters the detector
• Highly resistant to false alarms caused by steam smoke chamber and light is reflected from the smoke
particles to the receiving element. The light received is
converted into an electronic signal.
SPECIFICATIONS Signals are processed and compared to a reference
Light Source GaAlAs Infrared level, and when two consecutive signals exceeding the
Light Emitting Diode reference level are received within a specified period of
time, the time delay circuit triggers the SCR switch to
Rated Voltage 17.7 - 30.0 VDC
activate the alarm signal. The status LEDs light
Working Voltage 15.0 - 33.0 VDC continuously during the alarm period.
Maximum Voltage 42 VDC
Supervisory Current 45μA @ 24 VDC
Surge Current 160μA max. @ 24VDC PRODUCT LISTINGS
Alarm Current 150mA max. @ 24 VDC
Air Velocity Range 0-4000 fpm California
Ambient Temperature 32°F to 120°F (0°C to 49°C) State Fire
Marshal
Color & Case Material Bone PC/ABS Blend
Sensitivity Range 0.5 - 2.68%/ft 7272-0410:174
Mounting Refer to NS Conventional S1383
Detector Base Data Sheet
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0083 05/2010
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, Hochiki America Model SLV-24M marine photo-
electric smoke detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL
listed fire alarm panel.
The base shall be appropriate twist-lock base NS4-220 (Marine Type) and NS6-220 (Marine Type).
The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby
condition the LEDs will flash Green. When the detector is actuated, the flashing LEDs will latch on Red. The detector
may be reset by actuating the control panel reset switch.
The sensitivity of the detector shall be capable of being measured.
To facilitate installation, the detector shall be non-polarized. Voltage and RF/transient suppression techniques shall be
employed in the detector to minimize false alarm potential.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field removable when not required.

WIRING DIAGRAM

UL LISTED
CONTROL LISTED
PANEL END OF LINE
DEVICE

PANEL Resistor shown is for


example only. Not all
POWER annunciators have in
SUPPLY line resistance.

NEGATIVE
NS4-220 NS6-220
Annunciation device must be current limited to 20 mA @
24VDC Maximum. Not limiting current could result in
damage to the detector or cause a no alarm condition.

Hochiki America Corporation SLV-24M Specifications subject to change without notice.


DCD 135/190 FIXED TEMPERATURE/RATE OF RISE HEAT DETECTOR
APPLICATION
The DCD-135/-190 fixed temperature/rate-of-rise heat
detector are suited for installation where high heat output
fires are expected or in areas where ambient conditions
would not allow use of other detection methods. Heat
detectors are intended for protection of property. Do
not rely on heat detectors for life safety protection.
Where life safety is a concern, smoke detectors must
also be used. A UL listed fire alarm panel must
electronically supervise the DCD-135/-190 heat
detectors.

All NS conventional devices are mechanically compatible


with Hochiki America HSB, HSC and YBA type bases.
Please check individual panel listings for appropriate
Shown without base
listed bases.
STANDARD FEATURES
• Choice of fixed temperature/rate-of-rise OPERATION
135°F or 190°F heat detector
The DCD-135/-190 fixed temperature/rate-of-rise heat
• UL Listed spacing up to 60' by 60'
detectors are suited to detect in the presence of slow or
• 2 or 4 wire base compatibility, relay bases available
fast rising temperatures due to burning combustibles.
• Highly stable operation, RF/Transient protection
The construction of these models incorporate a
• Low standby current, 35μA nominal
thermistor heat element protected from damage by the
• Two built-in power/alarm LED's for 360° viewing
built-in, durable plastic guard. These electronic heat
• Fully electronic operation
detectors incorporate two power/alarm LED's for 360°
• Power/alarm LED's confirm detector status
indication of status. In standby condition the power LED's
• Compatible with Hochiki SLR-24V and SIJ-24
flash Green. In an alarm condition the LED's latch on
detectors and their bases
Red. The DCD-135/-190 electronic heat detection
circuitry performs the same function as a Mechanical
SPECIFICATIONS Device but with Electronic Precision. If the heat rise is
Response Temperature 135° ± 7.5°F less than 12°/minute the DCD will not alarm until it
Temperature 190° ± 7.5°F reaches its alarm temperature (135° or 190° ± 7.5°F). If
Supply Voltage 17.7 - 30.0 VDC (4 Wire) the heat rise is greater than 12°/minute the DCD will
15.0 - 33.0 VDC (2 Wire) alarm immediately giving an early warning signal and
Supervisory Current 40μA @ 24 VDC latching the Red alarm LED's on.
Surge Current 160μA max. @ 24 VDC
Alarm Current 150mA max. @ 24 VDC PRODUCT LISTINGS
Ambient Temperature 32°F to 120°F

Contact Rating
(0°C to 49°C)
N/O Contacts MEA
284-91E Vol. IV
150mA max. @ 24 V
Color & Case Material Bone PC/ABS blend 1D5A1.AY
California
Mounting Refer to the NS Conventional State Fire
Detector Base Data Sheet S2966 Marshal
7270-0410:151

Specifications subject to change without notice. Continued on back.

Find latest revision at www.hochiki.com


Hochiki America Corporation
7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0016 10/2012
ENGINEERING SPECIFICATIONS

Automatic heat detectors where ambient temperatures do not exceed 120°F shall be the DCD-135 fixed temperature/
rate-of-rise heat detector rated at 135°F. For areas where ambient temperatures exceed 120°F, but not 160°F, the
DCD-190 fixed temperature/rate-of-rise heat detector rated at 190°F shall be used. Electrical contacts shall be
normally open, rated at 150mA @ 24VDC.

Heat detectors shall be installed in accordance with National Fire Protection Association Standard 72, the spacing
assigned by Underwriters Laboratories and in accordance with the rules and regulations set forth by the local authorities
having jurisdiction. Automatic heat detectors shall be Underwriters Laboratories listed.

4-WIRE OPERATION
(+)
INITIATING LISTED
CIRCUIT END OF LINE
DEVICE
HSC-4R
CONTACTS
(-) H1
H2
YEL
ORN
PUR

UL LISTED (+) LISTED


POWER END OF LINE
SUPPLY RELAY
24VDC (-) HA-EOLR-24

HSC-4R HSC-4R

2-WIRE OPERATION

UL LISTED (+)
CONTROL LISTED
PANEL END OF LINE
DEVICE
(-)
PANEL Resistor shown is for example
POWER only. Not all annunciators have
in line resistance.
SUPPLY
(-)
NEGATIVE
NS4 SERIES NS6 SERIES
Annunciation device must be current limited to 20 mA @
24VDC Maximum. Not limiting current could result in
damage to the detector or cause a no alarm condition.

2-WIRE RELAY OPERATION

(+)

UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
TERMINAL BLOCK USED ON
HSC-224RA/RST VERSION ONLY
(-) HSC-(XXX)R (2-WIRE)
COM 6
GRY
N/C 5 BLU
GRN
N/O 4 YEL
ORN
HSC-RELAY SERIES N/O 3 PUR

N/C 2 2 AND 4 WIRE BASE


RELAYS SHOWN WITH
COM 1 POWER OFF.

Hochiki America Corporation DCD-135/-190 Specifications subject to change without notice.


DFE 135/190 FIXED TEMPERATURE HEAT DETECTOR
APPLICATION
The DFE 135/190 fixed temperature heat detector is
suited for installation where high heat output fires are
expected or in areas where ambient conditions would
not allow use of other detection methods.

Heat detectors are used for property protection. Do not


rely on heat detectors for life safety protection. Where
life safety is involved, smoke detectors must also be
used.

Heat detectors should be electronically supervised from


a UL listed alarm panel.

OPERATION
STANDARD FEATURES The DFE 135/190 fixed temperature heat detector is
suited to alarm in the presence of slowly rising
• Choice of fixed temperature - 135°F or 190°F temperatures. The construction of this model
• UL Listed ceiling spacing of 50' by 50' incorporates an oversized heat collector protected from
damage by the built-in, durable plastic guard. The DFE
(2,500 square feet) 135/190 fixed temperature heat detector used the proven
• Self-Restoring snap-disc principle of operation. This bi-metal disc
deflects when temperature reaches a predetermined
• Heat element protected by a built-in guard value. The disc deflection then causes a push-rod to
• Contact Rating of 100 mA close the internal contact resulting in an alarm condition.
The bi-metal disc returns to its normal shape when the
• Highly Dependable heat subsides causing internal contacts to return to their
normally open position. A standby condition is restored.
• Latching LED base available

SPECIFICATIONS
Response Temperature 135° ± 7.5°F
ENGINEERING SPECIFICATIONS
Temperature 190° ± 7.5°F Automatic heat detectors shall be fixed temperature rated
Contact Rating N/O Contacts at 135°F for areas where ambient temperatures do not
100mA @ 60 V exceed 120°F and 190°F where ambient temperatures
Maximum Humidity 95% RH Non-Condensing exceed 120°F but not 160°F. The fixed temperature el-
Color & Case Material Ivory ACS ement shall consist of a bi-metallic disc and actuator
Mounting Refer to back of this sheet shaft. Electrical contacts shall be normally open, rated
at 100mA @ 60VDC.
PRODUCT LISTINGS
Heat detectors shall be installed in accordance with
National Fire Protection Association Standard 72, the
California
State Fire MEA spacing assigned by Underwriters Laboratories, and in
accordance with the rules and regulations set forth by
284-91E Vol. II
Marshal the local authorities having jurisdiction. Automatic heat
7270-0410:119 detectors shall be Underwriters Laboratories listed.
S2966
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com 05/2014
COMPATIBLE BASES

HSC-(XXX)L HEAT DETECTOR BASE

The HSC-xxx L Series is a 6" base featuring a current limiting resistor, latching annunciator output
and a latching circuit so the alarm LED will remain lit until the control panel has been reset. Heat
detectors are not recognized as proper detection for life safety protection, therefore they should
be utilized only for the protection of property.

COMPATIBLE (+)
UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
3.9K 1/2W
(-)
Pig Tail Lead
PANEL
POWER (-)
SUPPLY
HSC-(XXX)L SERIES
NEGATIVE
Nominal alarm current shown at 24V. Polarized with annunciator output.
HSC-21L 24mA HSC-221L 41mA
HSC-224L 38mA HSC-220L 73mA

Hochiki America Corporation DFE-135/190 Specifications subject to change without notice.


DSC-EA RATE OF RISE THERMAL DETECTOR
STANDARD FEATURES
1. The DSC features a slim design which combines
visual appeal with a high standard of reliability.
2. The design of the DSC enables the detector to
operate in locations where the temperature is likely
to increase suddenly should a fire develop.
3. The operating characteristics of DSC is a key feature
of the product enabling a very cost effective solution
for the use of heat detectors. This detector consumes
no current in standby, which enables an unlimited
number of detectors to be connected on the same
detection wires.
4. With connection to the standard Hochiki range of
conventional bases, the DSC heat detector can be
connected or disconnected very easily, allowing
simple interchangeability with other members of the
Hochiki conventional detectors.
SPECIFICATIONS
APPLICATION
Rated Voltage: 24VDC
Working Voltage: 15 - 30VDC The DSC rate of rise heat detector is suitable for use in
Maximum Switching Current: 100mA max. most applications that require heat detection. Please
note that special attention should be given to avoid
Heat Sensing Element: Air chamber composed with
installation in direct line with hot air heaters, above
the diaphragm.
stoves, ovens or other heat generating objects.
Operating Temp. Range:
-10° C - +50° C OPERATION
(14°F - 122° F)
The DSC rate of rise heat detectors are composed of
Storage Temp. Range: -30° C - +70° C
an air chamber, vent and a flexible metal diaphragm.
(-22° F - 158° F)
When the DSC is heated, the air in the chamber
Relative Humidity expands. The vent permits the chamber to breathe and
(at 40° C): 95% RH Non-Condensing slowly release the expanded air. If a fire occurs, the air
Dimensions: 3.9 " D x 1.3" H in the chamber will expand more rapidly than it can be
Weight: 3 oz. vented. This causes the diagram to close a set of
Color: Bone precious metal contacts (nornally open) to trigger the
Applicable Standard: UL-521 alarm signal.
Response Grade: Ordinary
PRODUCT LISTINGS

California
State Fire
Marshal
7270-0410:0178
Specifications subject to change without notice. S2966
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com 07/2011
COMPATIBLE BASES

HSC-(XXX)L HEAT DETECTOR BASE

The HSC-(XXX)L Series is a 6" base featuring a current limiting resistor, latching annunciator
output and a latching circuit so the alarm LED will remain lit until the control panel has been
reset. Heat detectors are not recognized as proper detection for life safety protection, therefore
they should be utilized only for the protection of property.

COMPATIBLE (+)
UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
3.9K 1/2W
(-)
Pig Tail Lead
PANEL
POWER (-)
SUPPLY
HSC-(XXX)L SERIES
NEGATIVE

Nominal alarm current shown at 24V. Polarized with annunciator output.


HSC-220L 73mA
HSC-221L 41mA
HSC-224L 38mA

NS6-100 DETECTOR BASE

The NS6-100 is a 6" diameter base that has no current limiting nor annunciator output features.
A direct short occurs across the loop when the detector is actuated. Heat detectors are not
recognized as proper detection for life safety protection, therefore they should be utilized only
for the protection of property.

(+)
COMPATIBLE
UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
(-)
6 6

NS6-100
Non polarized, not current limited. No annunciator output.

We try to keep our product information up-to-date and accurate. However, we cannot cover
all specifications or anticipate all requirements. For additional information contact
your local distributor or call or write Hochiki America Corporation.

Hochiki America Corporation DSC-EA Specifications subject to change without notice.


SPC-24 PROJECTED BEAM SMOKE DETECTOR
APPLICATION
The Hochiki SPC-24 Projected Beam Smoke Detector
consists of an emitter and receiver. The SPC-24 detec-
tor should be placed so that smoke generated by a fire
will likely rise into the path of the beam. The receiver is
constantly monitoring and measuring the intensity of
the beam transmitted by the emitter. Should the smoke
from a fire cause a decrease in the signal strength of a
STANDARD FEATURES
magnitude that exceeds the programmed obscuration
 Microprocessor based for reliability
setting, an alarm signal is generated.
 Simple setup and alignment with signal strength LEDs
The SPC-24 detector can provide vital fire detection in
 Provides 60 feet on center linear protection at a range
of 32.8 feet to 328 feet applications where other types of detectors may not be
able to respond quickly, or at all, to a fire condition.
 Automatic compensation for signal drift or dirty lens
Examples of some applications where projected beam
 Three field adjustable sensitivity settings
smoke detectors have been successfully used include:
 Form A alarm and Form B trouble contacts
atriums gymnasiums theaters
 Calibrated filters available to verify sensitivity
(purchased separately) museums factories tunnels
 Color-coded emitter (red) and receiver (green) labels churches stables warehouses
for easy recognition
anechoic chambers high air velocity areas
 Adjustable to one of the three obscuration settings of
The SPC-24 detector may also be used in conjunction
25%, 50% or 70% per span
with more traditional spot type smoke detection devices
 Voltage and RF transient protection
to provide an even more comprehensive detection
 External red LED when alarm condition is indicated system.
SPECIFICATIONS
OPERATION
Rated Voltage 24VDC
Supply Voltage 19VDC - 33 VDC The near infrared pulsed beam generated by the emit-
Supervisory Current Emitter 50µA @ 24VDC
ter is sensed by the photodiode of the receiver, where it
is converted into an electrical signal. This signal is then
Receiver 200µA @ 24VDC
amplified and applied, via an analog to digital converter,
Alarm Current (Receiver) 20mA @ 24DC
to a microprocessor. The normal state signal (the initial
Trouble Current (Receiver) 20mA @ 24VDC
beam data), once stored in the microprocessor, is used
Operating Temperature Range 14° F - 122° F as reference for comparison with subsequent beam
UL Installation Temperature Range 32° F - 100° F signals.
Sensitivity Test Failure Hochiki test filters
(sold separately)
Allowable misalignment angle Emitter +/- 0.5° PRODUCT LISTINGS
(MAX) Receiver +/- 1.0°
California State
Dimensions 3.2”W x 5.5”H x 4.0”D
Fire Marshal
Mounting Wall mount or Single gang box
3054275 7260-0410:172
Maximum Humidity 95% R.H. non-condensing S1383
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0072 07/2015
SPC-24 PROJECTED BEAM SMOKE DETECTOR

OPERATION, continued
When there is a difference between actual beam strength and stored reference data that exceeds the programmed
alarm obscuration reference level, a fire signal is produced. A trouble signal is generated if the beam is more than
90% obstructed (as opposed to partially obscured by smoke) for more than 9 seconds and automatically resets to
normal when the blockage is removed.

The microprocessor also provides compensation for a change in received signal value, with time, caused by
contamination of the optics. Since such a change with time appears as a slow change in the beam signal, the micro-
processor compensates in such a manner that the signal moves closer to the reference data at a rate approximately
+1% per hour. When this compensating capability reaches a limit (light received has changed by more than 50%),
the SPC-24 automatically generates a trouble signal.

A calibrated test filter is available upon request to test and verify the sensitivity setting of the SPC-24 detector.

INSTALLATION
The Hochiki SPC-24 detector shall be installed in accordance with the installation instruction guide provided with
every unit. Please refer to the applicable NFPA Standards for additional guidance on spacing, irregular ceiling
surfaces and other design considerations.

FOUR WIRE CONNECTION TO THE CONTROL PANEL

NOTE: EOLR-24 required


NOTE: End of line relay and trouble contacts are closed for power supervision on
when power is applied. Receiver.

Hochiki America Corporation SPC-24 Specifications subject to change without notice.


HF-24 ULTRAVIOLET FLAME DETECTOR
APPLICATION
The HF-24 is suited for use wherever there is a need for
automatic detection of fires which can develop quickly
or where contents have great value.

Suggested applications include:


• Petroleum Storage
• Photographic or Film Storage
• Computer Rooms
• Print Shops
• Museums

The HF-24 is not a substitute for smoke or heat detectors,


but is an added level of protection against fast flaming
fires only.
STANDARD FEATURES
There is no set area for which the HF-24 Ultraviolet
• Detects fast flaming fires Detector is able to cover. The reason is that the size of
• Highly reliable, long life UV receptor tube the fire and the distance from this fire to the detector all
• Low power consumption effect how the detector will respond. There is one non-
• HF-24 can be intermixed with other types of variable, however, and that is very small fires must have
detection on the panel's detection circuitry a duration of at least 7-15 seconds if within 12 feet, 20-
• Interchangeable with Hochiki America's standard 30 seconds at 25 feet.
smoke and heat detector bases.
• Size and color similar to other Hochiki America
smoke and heat detectors.
OPERATION
• Easily Maintained - cleaning can be accomplished The HF-24 uses an ultraviolet detector tube which absorbs
without disassembling the detector. very weak ultraviolet light such as that emitted from a
• Not UL Listed flame. This is detected as a train of discharge pulses
creating a current. The electronic circuitry in the detector
SPECIFICATIONS body translates this action as an alarm signal. There is
Rated Voltage: 17.6 - 27.7 VDC a counter circuit which prevents the alarm from occurring
Working Voltage: 15 - 30 VDC from one-shot ultraviolet light such as lightning or cosmic
Normal Current: 200ì A @ 24 VDC flares. Additionally there are circuit refinements which
Alarm Current: 250mA Maximum limit the detection of only wave lengths from 1850 to 3000
Response to Ultraviolet: 1850 - 3000 Angstrom angstroms thus ignoring visible and infrared light.
Ambient Temperature:
14° to 122° Fahrenheit (-10° C to +50° C)
See Reverse Side for
Mounting: HSC-4R, HSB series, Detection Range Graph
NS4 series, NS6 series & and Wiring Diagram.
HSC-xxx L series bases
Color: Ivory ACS
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0011 09/2004
DETECTION RANGE

Ceiling
#1
120°
2m
#2
3m
Ceiling Height

4m
5m
6m
7m
8m

Floor

# 1: Flame from a candle or lighter


# 2: Flame from a wad or newspaper, burning flame

WIRING DIAGRAMS

NS Series and HSC Series Base

(+) HSC SERIES NS6 SERIES NS4 SERIES


COMPATIBLE
UL LISTED
CONTROL
PANEL
LISTED
END OF LINE
DEVICE

PANEL
POWER (-)
SUPPLY

HSB-2 Wire

UL LISTED
CONTROL
(+)
PANEL
LISTED
END OF LINE
DEVICE
(-) 3.9K 1/2W
PANEL
POWER 16mA MAX.
SUPPLY OUTPUT
(-) 16mA MAX.
OUTPUT
NEGATIVE CURRENT LIMTED AT 24VDC

Hochiki America Corporation HF-24 Specifications subject to change without notice.


DH-98 CONVENTIONAL DUCT DETECTOR
STANDARD FEATURES
• Detects and limits the spread of smoke throughout
building HVAC ducts
• Ability to interconnect (all relays operate with a single
alarm) up to 30 units using the same independent
power supply
• Compatible with building automation and fire
alarm systems
• Installs quickly and easily
• Interchangeable “Plug-In” photoelectric or
ionization heads
• No screens or filters to clean
• Cover provides magnet window and
placement guide for operational testing without
Duct housing is available with either a conventional
photoelectric or ionization detector. disassembly
• Rugged gray steel back box with clear cover
• Accessories - Remote power, remote alarm
SPECIFICATIONS indication capability and remote, horn/piezo
Duct Detector Model # DH-98-P DH-98-HVP
capability
Operating Voltage 115V AC,
24V AC/DC
230V AC,
24V AC/DC
• Meets UL 268A Requirements
Detector Head Model SLR-24DH
Conventional
SLR-24DH
Conventional
DESCRIPTION
Detector Head Type
Photoelectric Photoelectric
Power Requirements 8mA
The HOCHIKI AMERICA DH-98 Duct Smoke Detector
230 VAC
Standby
115 VAC 14mA
provides early detection of smoke and products of
24 VAC 20mA 20mA
combustion present in air moving through HVAC ducts in
24 VDC 13mA 13mA Commercial, Industrial and Residential applications. The
Power Requirements
Alarm
230 VAC 15mA DH-98 is designed to prevent the recirculation of smoke in
115 VAC 28mA
areas by the air handling systems, fans and blowers.
24 VAC 95mA 95mA
Complete systems may be shut down in the event of smoke
24 VDC 60mA 60mA
1 form "C" and 1 form "C" and
detection. The HOCHIKI AMERICA DH-98-P operate on
Alarm Contacts
1 form "A" rated
at 10 amps @
1 form "A" rated
at 10 amps @
115 VAC, 24 VAC and 24 VDC and the DH-98-HVP operate
125 VAC. 250 VAC on 230 VAC, 24 VAC and 24 VDC.
Detection Loop 1 Form A (1A) 1 Form A (1A)

Trouble Contacts 1 Form "C" rated at 10 amps 1 Form "C" rated at 10 amps
@ 125VAC @ 250VAC
The DH-98 is designed and built to meet all local
Sensitivity Test Method Self Diagnostic Self Diagnostic
Test Test requirements, as well as the NFPA regulations regarding
Remote Indication Capability Power, Alarm, Power, Alarm, duct smoke detectors. Output terminals are provided for
(Refer to DH-98 Accessories Horn/Piezo, Horn/Piezo,
Data Sheet for Specifications) Test Test remote accessories such as a horn, strobe, remote status
Air Velocity 300 to 4000 ft./min
indicators and reset key switches or push buttons.
Ambient Temperature 32°F to 100°F (0°C to 38°C)

Humidity 10% to 85% Relative Humidity (non-condensing) PRODUCT LISTINGS


Housing Material 18 G.A. steel backbox, clear plastic cover

Finish Grey Paint


California
Dimensions 9 1/8"L X 7 1/4"W X 2 1/4"H
State Fire
Maximum Net Weight 3 lbs. Marshal 3005751
Sampling Tubes 2.5 ft., 5 ft. or 10 ft.
3240-0410:155
Radioactive Element DH-98-I and DH-98-HVI Only: Americum 241 0.5 Mirco-Curie S1383
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0038 03/2011
PRODUCT DESCRIPTION, continued
Air sampling is accomplished by two tubes which protrude into the duct. An exhaust tube of one standard length (7.5")
is supplied in the installation kit with the smoke duct unit. Once the duct width has been determined the air intake
sampling tubes must be ordered. Sampling tubes are supplied in three standard lengths 2.5 ft., 5 ft. and 10 ft. and cut
to size to fit the duct. Mounting the duct smoke unit is accomplished by the use of a template and 4 sheet metal
screws, which are provided. Mounting can be achieved without the removal of the clear cover which is secured by 4
capture screws.

The compact DH-98 contains 3 sets of alarm contacts; 1 set of form “C” contacts rated at 10 amps, 1 set of form “A”
contacts rated at 10 amps and 1 set of form “A” contacts rated at 1 amp. There is also 1 set of form “C” 10 amp trouble
contacts for monitoring detector head removal, and the failure of the input supply voltage.

The pilot and alarm visual indicators provided on the front of the DH-98 duct unit signal the operating status of the
device. A manual test/reset switch is located along side the visual indicators.

ENGINEERING SPECIFICATIONS
Air duct smoke detectors shall be HOCHIKI AMERICA DH-98 Series. The detectors shall be listed by Underwriters
Laboratories per UL 268A. The detectors shall operate at air velocities from 300 feet per minute to 4000 feet per minute.
The detectors shall have the ability to interconnect up to 30 units using the same independent power supply.

The duct detector housings shall be of metal construction and complete mechanical installation may be performed
without removal of the detector cover. Visual indication of alarm and power must be provided on detector front. A manual
reset switch shall be located on the front of the device. Detector heads shall not require additional filters or screens
which must be maintained. The housing shall contain a detector base which will accept photoelectric or ionization
detector heads. Terminal connections shall be of the screw type and be a minimum of # 6 screw. Terminals shall be
provided for remote pilot, remote alarm indication, strobe/horn and remote key switch. All wiring must comply with local
codes and regulations.

WIRING DIAGRAMS S ee A LA R M A LA R M *T R O U B L E REMO TE


P ower CONTACTS CO NTACTS CO NTACTS A C C E S S O R IE S
C o n n e c tio n s 1 0 .0 A @ 1 1 5 V A C 1A @ 24V DC 10.0A @ 11 5V A C

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

* T ro u b le c o n tac ts a re sh o w n in n o n -e n e rg ize d
c o n d itio n . T ro u b le c o n tac ts m o n ito r p o w e r
D H -9 8 D U C T S M O K E D E T E C T O R c o n n e c te d a n d h e a d re m o v ed .

24V A C , 60H z 24V D C


@ 0 .1 A M P M A X .(D e te c to r o n ly ). @ 0 .1 A M P M A X .(D e te c to r o n ly ).
U P T O 1 . 9 A M P S F O R A U X IL IA R Y U P T O 1 .9 A M P S F O R A U X IL I A R Y
O U T P U T S (H O R N S /S T R O B E S ). O U T P U T S (H O R N S /S T R O B E S ).

- +

1 2 3 4 5 6 1 2 3 4 5 6

D H -9 8 -P
-I D H --9988 -P

2 4 V .A . C . O P E R A T IO N 2 4 V .D .C . O P E R A T I O N

1 1 5 V A C 6 0 H z IN P U T 2 3 0 V A C 6 0 H z IN P U T
@ 0 .1 A M P M A X . @ 0 .1 A M P M A X .

G N H G N H

1 2 3 4 5 6 1 2 3 4 5 6

D H -9 8 -P
-I D H -9 8 -H V P
I

1 1 5 V .A .C . O P E R A T IO N 2 3 0 V . A . C . O P E R A T IO N

INTERCONNECT WIRING DIAGRAMS


DUCT UNIT #1 DUCT UNIT #2 DUCT UNIT #3

INPUT
P
POWER
P

Input Power Source


Will Be Either 16 16 16
24V, 115V or 230V
18 18 18

Hochiki America Corporation DH-98 Conventional Specifications subject to change without notice.
DUCT DETECTOR REMOTE ACCESSORIES
APPLICATION SPECIFICATIONS
The Duct Detector Remote Accessories are designed Power Requirements
to be used with the DH-98 Conventional and DH-98/ Alarm LED 15 mA
DH-99 Analog Duct Detectors to provide audible and Pilot LED 15 mA
visual indication as well as remote test/reset functions. Horn 20 mA @ 24 VDC
Sound Pressure
These devices are contructed of brushed stainless Horn 78 db @ 10 feet
steel and mount on a standard single or double gang Dimensions
backbox. Single Gang 2.75" (69.85mm) W
4.5" (114.3mm) H
Double Gang 4.5" (114.3mm) W
4.5" (114.3mm) H

MS-RA MS-KA/P/R
Functions: Functions:
Remote Alarm LED (red) ALARM
Remote Alarm LED (red)
For Use with: Pilot LED (green)
ALARM
DH-98-I, DH-98-P PILOT
Key-Operated Test/Reset
DH-98-HVI, DH-98-HVP Switch
DH-98-AR, DH-99-AR For Use with:
TEST/RESET
DH-98-I, DH-98-P
DH-98-HVI, DH-98-HVP

MS-KA/R MS-RA/R
Functions: Functions:
ALARM Remote Alarm LED (red) Remote Alarm LED (red)
Key-Operated Test/Reset ALARM
Push-button Test/Reset
Switch Switch
For Use with: For Use with:
DH-98-I, DH-98-P TEST/RESET DH-98-I, DH-98-P
TEST/RESET
DH-98-HVI, DH-98-HVP DH-98-HVI, DH-98-HVP
DH-98-AR, DH-99-AR DH-98-AR, DH-99-AR

MS-RA/P MS-RA/P/R
Functions: Functions:
Remote Alarm LED (red) Remote Alarm LED (red)
ALARM
ALARM Pilot LED (green) Pilot LED (green)
For Use with: Push-button Test/Reset
PILOT
DH-98-I, DH-98-P Switch
PILOT DH-98-HVI, DH-98-HVP For Use with:
TEST/RESET DH-98-I, DH-98-P
DH-98-HVI, DH-98-HVP

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com 05/2013
MS-RH/KA/P/R
Functions:
Remote Alarm Horn
ALARM
Remote Alarm LED (red)
Pilot LED (green)
PILOT Key-Operated Test/Reset
Switch
TEST/RESET
For Use with:
DH-98-I, DH-98-P
DH-98-HVI, DH-98-HVP

WIRING DIAGRAM
RED
RED

RED GREEN
ALARM
24VDC PILOT
24VDC ALARM HORN
LED LED

BLACK
BLACK
ALARM
PILOT

BLACK

KEY OR
PUSH BUTTON
24VDC
"TEST/RESET"
SWITCH

BLACK

TEST/RESET

PRODUCT SPECIFICATIONS
PUSH KEY
PILOT ALARM BUTTON OPERATED
LED LED TEST/ TEST/ SINGLE DOUBLE
(GREEN) (RED) RESET RESET HORN GANG GANG
MODEL #
MS-RA
MS-RA/P
MS-RA/R
MS-RA/P/R
MS-KA/R
MS-KA/P/R
MS-RH/KA/P/R

Hochiki America Corporation Duct Detector Remote Accessories Specifications subject to change without notice.
CONVENTIONAL DETECTOR BASES
NS6 AND NS4 SERIES BASE
The NS6 and NS4 series bases are designed specifically for use with
Hochiki’s conventional models:
 Photoelectric smoke detectors: SLR-24V, SLV-24, SLV-24N, SLV-
24V, SLR-835, SLR-24H
 Photoelectric with heat smoke detector: SLR-835H
 Fixed temperature/rate-of-rise heat detector: DCD-135/190

NS Series Bases Alarm Current ID


The NS6 base is an electronics free 6" base featuring a plastic tam-
per-lock lug. Each base is equipped with a resistor. Please refer to
the chart (left) for additional specifications. The NS4 base is a 4"
NS6-224 OR NS4-224 43mA (70mA @ 33.0V MAX) HB-5
version of the NS6 base.
NS6-220 OR NS4-220 93mA (136mA @ 33.0V MAX) HB-3 Models HSC-224R, HSC-220R and the HSC-221R are designed
specifically for use with the Hochiki conventional models SLR-24H,
NS6-221 OR NS4-221 46mA (77mA @ 33.0V MAX) HB-4 SLR-24V, SLV-24, SLV-24N, SLV-24V, SLR-835, SLR-835H, DCD-
135/190. The HSC-(X)R series is a 6" base with two sets of Form "C"
NS6-100* OR NS4-100* 150mA @ 15.0-33.0V MAX HB-55 relay contacts.

* Requires external current limiting to 150mA maximum Models HSC-224R, HSC-220R and the HSC-221R are also approved
for use with Hochiki’s previous conventional model DFE 135/190.

HSC-(X)R RELAY BASE & HSC- 4R 4 WIRE BASE The HSC-4R is designed specifically for 24 volt 4 wire applications
using Hochiki conventional models SLR-24H, SLR-24V, SLV-24, SLV
-24N, SLV-24V, SLR-835, SLR-835H or DCD-135/190. The 6" diame-
ter base is current limited. Relay contact place a direct short circuit
across the loop when the detector is actuated.
Model HSC-4R is also approved for use with Hochiki’s previous
conventional model DFE 135/190.
The HSC-L base series are designed specifically for use with the
2 Wire Auxiliary Relay Hochiki fixed temperature heat detectors (models DFE-135/190).
Alarm Current ID
Bases
The HSC-L series is a 6" base featuring a current limiting resistor,
HSC-224R 43mA (58mA @ 30.0V MAX) HB-73 latching annunciator output and a latching circuit so the alarm LED
will remain lit until the control panel has been reset.
HSC-220R 88mA (98mA @ 26.5V MAX) HB-72 Bases are available in bone or white to match the detector. Bone (off-
white) is the standard color for detectors and bases for most applica-
HSC-221R 49mA (62mA @ 30.0V MAX) HB-71
tions.
4 Wire Base Alarm Current ID
BOX MOUNTING
HSC-4R 43mA (58mA @ 30.0V MAX) N/A BASE
3" OCT 4" OCT 4" SQR

HSC-(X) L LATCHING LED BASE NS4-BASE YES NO NO

NS6-BASE NO YES YES

HSC-BASE NO YES YES

PRODUCT LISTINGS

2 Wire Latching Alarm Current ID California State


Fire Marshal
HSC-224L 35-42mA @ 24V (54mA MAX) HB-62 7300-0410-0132
S1383 1D5A1, A4
67-80mA @ 24V
HSC-220L HB-64
(88.5mA @ 26.5V DC MAX)
We try to keep our product information up-to-date and accurate. However, we
HSC-221L 37-45mA @ 24V (57mA MAX) HB-63 cannot cover all specifications or anticipate all requirements. For additional
information contact your local distributor or Hochiki America Corporation.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0014 08/2015
CONVENTIONAL DETECTOR BASES
NS4 AND NS6 SERIES BASE
2-WIRE OPERATION
UL LISTED
CONTROL 4 3 1 2 LISTED
PANEL 1 4 END OF LINE
2 DEVICE
6 5
6 5
PANEL Resistor shown is for example
POWER only. Not all annunciators
have in line resistance. NOTE:  WIRING TERMINALS FOR THE NS4
3 AND NS6 ARE IDENTICAL
SUPPLY
NEGATIVE NS4 SERIES  BASES ARE AVAILABLE IN BONE OR
NS6 SERIES WHITE TO MATCH THE DETECTOR.
BONE (OFF WHITE) IS THE STANDARD
Annunciation device must be current limited to 20 mA @ 24VDC
Maximum. Not limiting current could result in damage to the
COLOR FOR DETECTORS AND BASES
detector or cause a no alarm condition. FOR MOST APPLICATIONS.
 BASES WITH THE “W” SUFFIX ARE
HSC-(X)R RELAY BASE WHITE IN COLOR

2-WIRE OPERATION
UL LISTED
CONTROL LISTED
END OF LINE
PANEL L4 L4 DEVICE
H2 H2
L3 L3 GRY
BLU
PIGTAIL AUXILLIARY
S1 H1 S1 H1
S2 S2
GRN
YEL
CONTACTS
ORN
PUR
TWO FORM “C”
L1 L1
L2 L2 RELAYS SHOWN WITH POWER OFF.
HSC-(X) R SERIES Relay Contact Ratings: 2A @ 30VDC
1A @ 120VAC

HSC-4R FOUR WIRE BASE


4-WIRE OPERATION
LISTED
INITIATING END OF LINE
CIRCUIT DEVICE H1,H2 - TERMINAL
H1
H2
PIGTAIL AUXILLIARY
YEL
ORN CONTACTS ONE
PUR
FORM “C”
LISTED Relay Contact Ratings: 2A @ 30VDC
L3 END OF LINE 1A @ 120VAC
UL LISTED L4 L4 RELAY
POWER H2 H2
HA-EOLR-24
SUPPLY S1 L3
24VDC S1 H1 H1
S2 S2

L1 L1
L2 L2

HSC-4R

HSC-(X) L LATCHING LED BASE


2-WIRE OPERATION
1 2
L4 4
UL LISTED H2
CONTROL L3 6 5
PANEL S1 LISTED
S2
H1 END OF LINE
DEVICE
3
PANEL L1
L2 PIG TAIL LEAD
POWER
SUPPLY
NEGATIVE HSC-(X) L SERIES NS6 SERIES

We try to keep our product information up-to-date and accurate. However, we cannot cover all specifications or anticipate all requirements.
For additional information contact your local distributor or Hochiki America Corporation.

Hochiki America Corporation Conventional Detectors Bases Specifications subject to change without notice.
TSE-A100 SELF-CONTAINED SMOKE GENERATOR
APPLICATION
The Hochiki America TSE-A100 is one of the most
advanced units of its kind and is the result of extensive
research and development aimed at making the job of
testing detectors a simple and efficient operation .

The TSE-A100 can be used to test all types of smoke


detectors by applying smoke from an internal smoke
source.

Although this is not a calibrated amount of smoke, the


TSE-A100 is an excellent choice for periodic functional
testing of smoke detectors.

OPERATION
Preparation
1. Remove the TSE-A100 from its carrying case.
2. Unscrew the combustion chamber from the
bottom of the TSE-A100.
3. Unscrew the punk stick holder retainer from
the combustion chamber.
4. Insert a punk stick into the punk stick holder in
the combustion chamber.
5. Light the punk stick with a flame.
STANDARD FEATURES 6. Reassemble the combustion chamber.
• Tests all types of smoke detectors. 7. Screw the combustion chamber back into the
• Completely self contained and portable. bottom of the TSE-A100
• Extends from 5.25 feet to 14.1 feet. 8. Extend the telescopic pole of the TSE-A100 to
• Internal Smoke Source. a length which enables you to reach the
• Non-Toxic Smoke Source. detector you wish to test.
• Unit includes shoulder sling carrying case.
• Optional adapter for high velocity conditions. Testing a Detector
Once you have prepared the TSE-A100, follow the steps
• Exhaust function to clear detector.
in this section to test smoke detectors.
• Built-in filter to prevent tar residue from adhering to
the surface of the detector. NOTE: Allow 30 to 60 seconds after igniting punk stick
for sufficient smoke generation.
SPECIFICATIONS
Continued on back
Rated Voltage 3 VDC
Battery 2 - "D" Batteries
PRODUCT PARTS
Combustion Material Punk Stick
(7 mm diameter, 150 mm long) • TSE-A100 Self-Contained Smoke Generator
Weight 5 Lbs. • Punk Stick (Part No. TSE-P100)
Length 5.25 to 14.1 feet
Color Brown
Specifications subject to change without notice.

Hochiki America Corporation


7051 Village Drive, Suite 100 • Buena Park, CA 90621-2268
Phone: 714/522-2246 • Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com 01/2002
OPERATION, continued

Testing a Detector, continued Storing the TSE-A100

1. Rotate the combustion chamber so the #2


1. Rotate the combustion chamber to the #1
arrow line sup with the power indicator screw.
position to turn the power off.
The fan powers on and a steady flow of smoke
is released from the tip of the TSE-A100. 2. Compress the telescopic pole to its shortest
length.
2. Raise the extended tip of the TSE-A100 to
within 6-8' of the detector. The detector should 3. Replace the TSE-A100 in its carry case.
alarm. 4. Store in a cool, dry place.
If no smoke comes out, check to make sure the 5. For extended storage, remove the batteries.
punk stick is ignited, and the power indicator on
the combustion chamber is set to #2.

NOTE

1. Use only the filter and combustion material


specified.
2. Check battery capacity before use to assure
efficient operation.
3. Remove batteries before long-period storage.
Telescopic Pole

Power Indicator Screw

Punk Stick Holder Retainer

Combustion Chamber
Punk Stick

Instruction Label

Hochiki America Corporation • TSE-A100 Specifications subject to change without notice.


NSRT / NSTT
SMOKE DETECTOR REMOVAL TOOL / TESTER

STANDARD FEATURES

NSRT-C/NSRT-H

• Combination removal tool/outer cover removal tool


for ATG, AIE, ALG, ALK, SIJ, and SLR-24/-835
series sensors/detectors.
• 15’ stainless steel extension pole with easy grip
black handle. (For NSRT-C model only)

NSTT-C/NSRT-H

NSRT-H • Tests Hochiki America SIJ-24 and SLR-24/-835


series smoke detector with a reed switch.
• 15’ stainless steel extension pole with easy grip
black handle. (For NSTT-C model only)
• No combustion material needed.
• No meter, batteries, or screwdriver required.
• Meets outlined requirements in the NFPA72,
NSRT-C WITH 15' POLE Inspection, Testing and Maintenance, Chapter 14.
(COMPLETE)

SPECIFICATIONS
Detector Tester/Removal Tool
Dimensions
NSRT-H: 4.0" D x 2.0" H
NSTT-H: 4.0" D x 1.5" H
Material Plastic Black Delrin
Color Black - provides visible contrast
Alignment
NSRT-H: One side for arrow labels for
easy visibility, one side for
removal from base.
NSTT-H: One side for sensitivity testing.

NSTT-H Extension Pole

Dimensions Pole extends to 15'


Material Stainless steel with easy grip
black handle
NSTT-C WITH 15' POLE
(COMPLETE) Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F044 10/2013
APPLICATION
NSRT-C
The Hochiki America NSRT-C will enable the user to easily remove and replace the ATG, ALG, AIE, ALK, SLR, and SIJ
series sensors/ detectors from their mounting bases. Also, the NSRT-C is designed to remove the outer covers of the
ALG, AIE and SLR series sensors/detectors

NSTT-C
The SIJ-24 and SLR-24/-835 series detectors, manufactured with magnetically activated dual reed switches for sensitivity
testing, can be sensitivity tested with the NSTT-C. This meets the requirements of a UL listed calibrated test without
the use of combustion materials.
The NSTT-C is in compliance with the test requirements outlined in the NFPA 72 Inspection, Testing and Maintenance,
Chapter 10.

Hochiki America Corporation NSRT & NSTT Specifications subject to change without notice.
TRT-A100 SMOKE DETECTOR TESTER/REMOVAL TOOL
APPLICATION
The HOCHIKI America TRT-A100 Smoke Detector Tester/
Removal Tool enables the user to access, test, remove
and reinstall the SIH and SLK series smoke detectors.
The detectors, manufactured with a magnetically
activated dual reed switch for sensitivity testing, can be
sensitivity tested. This meets the requirements of a UL
listed calibrated test without the use of combustion
materials.

The TRT-A100 is in compliance with the test requirements


outlined in the NFPA 72 Inspection, Testing and
Maintenance, Chapter 7.
OPERATION
Test Procedure

This method of sensitivity testing is designed only for


HOCHIKI America smoke detector models SIH and SLK
Series that contain a label which identities this specific
feature. See below. DO NOT attempt to use this method
of sensitivity testing on detectors without this label.
STANDARD FEATURES
• Combination tester/removal.
• Tests Hochiki America smoke detectors with a
dual reed switch.
• Choose either a Hand held or 15' stainless steel
extension pole with easy grip black handle.
• No combustion material needed.
• No meter, batteries, or screwdriver required.
• UL listed.
• Meets outlined requirements in the NFPA 72 Conduct the testing with detector wired to appropriate
Inspection, Testing and Maintenance, Chapter 7. initiating circuit or current limited power source and with
normal applied power. Abnormal or low power conditions
SPECIFICATIONS may effect sensitivity. Always reset the power before
you test the next unit.
Detector Tester/Removal Tool
Dimensions 3.4" D x 2.4" H 1. Place the TRT-A100 onto the detector aligning the
Material Highly durable PVC orange arrow shown on the removal/test tool with
molded plastic the tamper resistant set screw on the detector.
Color Gray-provides visible contrast 2. Wait six to eight seconds. Detector SHOULD NOT
Alignment One side for test, one side alarm.
for removal. Color-coded PRODUCT LISTINGS
labels for easy visibility
Tester/Removal Tool Handle
Options
Dimensions
Hand Held or Extension Pole
Pole extends to 15'
MEA
284-91E Vol. II
Material Stainless steel with
easy grip black handle
S1316
Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com 10/2010
OPERATION, continued

3. If the detector does alarm when the removal/test tool is placed in this position, the detector is not within specified
sensitivity limits and may require service.
4. Rotate the TRT-A100 one-half circle (180°). Align white arrow shown on tester tool with tamper resistant set
screw.
5. Wait six to eight seconds. Detector SHOULD alarm and the indicator LED should remain lit.
6. If detector does not alarm when the TRT-A100 is positioned correctly, may not within specified sensitivity limits
and may require service. See Technical Bulletin HA-88 (November '96) for more information.

Removal Procedure

This section explains how to use the HOCHIKI America TRT-A100 Tester/Removal Tool to remove smoke detectors
from their bases.

1. Flip the TRT-A100 so the five small arrows located beneath the white orange arrows are point upward.
2. Fit the TRT-A100 to the detector and lock into place.
3. To remove a detector, rotate the TRT-A100 to the left (counterclockwise).
4. To install a detector, rotate the TRT-A100 to the right (clockwise).

Hochiki America Corporation TRT-A100 Specifications subject to change without notice.


TCH-B100 HAND-HELD PROGRAMMER

APPLICATION

TCH-B100 is designed for use with all analog sensors


and modules.

ADDRESS SETTING:

1. Install sensor onto programmer, ensuring that


sensor protrusions align with programmer grooves.
2. Press the left gray button to switch programmer on.
A battery check message will appear followed by
the device's address (Unprogrammed sensors will
read address 127).
STANDARD FEATURES 3. Set the required address by incrementing the left
and right gray buttons (the display will show three
• Compact unit red flashing dots if the address being programmed
• Easy to use is different from the device's current address).
• Provides address setting and reading 4. When the desired address is present, press the red
• Can be used on both sensors and modules button to store that address. The three red dots on
the display will no longer be present.
• Has the diagnostic ability to display the
analog value
• Over 8000 address settings from one battery.

SPECIFICATIONS
Rated Voltage: 9 VDC
Battery: 9 VDC
Weight: 0.34 lbs
PRODUCT PARTS
Length: 6 1/4"
• 9 Volt Battery
Color: White
• Remote Programming Cables

Continued on back

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 • Buena Park, CA 90621-2268
Phone: 714/522-2246 • Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com 9/2003
Remote Programming
Jack

Programming Buttons
Display

PROGRAMMING BUTTONS:

LEFT GRAY BUTTON Power on. Automatically reads the addresss of a sensor.
Subsequent operations will advance the device address by ten.
RIGHT GRAY BUTTON Power off. Advances the device address by one.
RED BUTTON Stores the displayed address to the device and is used to read sensor analog
levels.

NOTE: Prior to programming, ensure battery is connected.

Remote Programming Cable


(All Modules except DCP-FRCME-S)

To Remote
Programming Jack

Remote Programming Cable


(DCP-FRCME-S)
TESTING A SENSOR
Note: Ionization sensors require a 30 second stabilization period before analog value reading should be taken.

1. Install the sensor and power up programmer as previously described on page 1


2. Press the “Red” button. An “A” will appear on the display followed by the analog value. The
value will be continuously updated for three minutes
3. The “ALG’ photoelectric sensor should have a value displayed of between 56-63. The “AIE”
ionization sensor should have a value displayed of between 52-73.

Values out of these ranges indicate that the sensor chamber has become contaminated. Refer to technical
bulletin “HA-96” for proper servicing instructions or return sensor to factory for servicing.

DISPLAY MESSAGES:
bAt- On upon power up (battery check). Also on when battery is low. Low battery good for up to 3,000
address setting operation.
E0 - Attempting to set an address beyond 127.
E1 - Attempting to program an address with no device connected.
E2 - Can not find device after power up.
E3 - Invalid sensor response.
E4 - Can not find the device program.
E5 - Device read error.
E6 - Fail during Analog value reading
Hochiki America Corporation • TCH-B100 Hand-Held Programmer Specifications subject to change without notice.
FN-300-ULX, FN-400-ULX, FN-600-ULX, FN-1024-ULX
SPECIFICATIONS
FN-300-ULX:
• 24VDC or 12VDC rated @ 2.5 amps max
• Input 115VAC / 60Hz, 1.45 amps
• 12VDC or 24VDC selectable output
• Maximum charge current 0.7 amps
• Enclosure size of 13"H x 13.5"W x 3.25"D

FN-400-ULX:
• 24VDC or 12VDC rated @ 3 amps max
• Input 115VAC / 60Hz, 1.45 amps
• 12VDC or 24VDC selectable output
• Maximum charge current 0.7 amps
• Enclosure size of 13"H x 13.5"W x 3.25"D

FN-600-ULX:
• 24VDC or 12VDC rated @ 6 amps max
• Input 115VAC / 60Hz, 1.9 amps
• 12VDC or 24VDC selectable output
• Maximum charge current 0.7 amps
• Enclosure size of 13"H x 13.5"W x 3.25"D
DESCRIPTION FN-1024-ULX:
• 24VDC or 12VDC rated @ 10 amps max
The FN-300-ULX, FN-400-ULX, FN-600-ULX, and FN-
• Input 115VAC / 60Hz, 4.4 amps
1024-ULX are extremely cost effective voltage regu-
• 24VDC output
lated remote Power Extenders. These power supply/
• Maximum charge current 3.6 amps
charger s convert a 115VAC / 60Hz input, to a 12VDC
• Enclosure size of 15.5"H x 12"W x 4.5"D
or 24VDC regulated output. The ULX series Power
Extenders are designed to provide auxiliary power to
support system accessories. STANDARD FEATURES
• Input fuse rated @ 3.5 amps/250V
• Filtered and electronically regulated output
• Short circuit and thermal overload protection
• AC fail supervision (form "C" contacts)
• Low battery supervision (form "C" contacts)
PRODUCT LISTINGS • Battery presence supervision (form "C" contacts)
• Built-in charger for sealed lead acid or gel type
batteries
California • Automatic switch over to stand-by battery when AC
3022852 State Fire
fails
MEA
Marshal
• Zero voltage drop when switched over to battery
NYC Department backup
S8680 of Building 7315-0410:167
168-92-E Vol. 12 7315-0410:168
• AC input and DC output LED indicators
• Accommodates up to two (2) 12VDC/7AH batteries
• Power supply, enclosure, cam lock and battery leads

Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F00109 06/2010
FN-642-ULADA, FN-842-ULADA, FN-1042-ULADA
SPECIFICATIONS
FN-642-ULADA:
• 24VDC OR 12VDC rated @ 6.5 amps max
• Four (4) Class A or Four (4) Class B outputs
• Enclosure size of 18"H x 14.5"W x 4.625"D

FN-842-ULADA:
• 24VDC OR 12VDC rated @ 8 amps max
• Four (4) Class A or Four (4) Class B outputs
• Enclosure size of 18"H x 14.5"W x 4.625"D
FN-1042-ULADA:
• 24VDC OR 12VDC rated @ 10 amps max
• Four (4) Class A or Four (4) Class B outputs
• Enclosure size of 18"H x 14.5"W x 4.625"D
STANDARD FEATURES
• Two (2) Class A or (2) Class B FACP inputs
• Two (2) NC dry contact trigger inputs
• Four (4) Class A or Four (4) Class B indicating
circuits
• Two (2) Class B outputs may be paralleled for
DESCRIPTION more power on an indicating circuit
The FN-642-ULADA, FN-842-ULADA, and FN-1042- • One (1) Aux. Power Output @ 1 amp supply
ULADA are extremely cost effective voltage regulated current (with or without battery back up)
remote NAC Power Extenders. They may be con- • Signal Circuit Trouble Memory - Facilitates quickly
nected to any 12 or 24VDC Fire Alarm Control Panel locating intermittent system trouble and eliminates
(FACP). Primary applications include Notification costly and unneccessary service calls. LED's
Appliance Circuit (NAC) expansion (supports ADA indicate a prior fault (short, open, ground) has
requirements) and will provide auxiliary power to occured on one or more signaling circuit outputs.
support system accessories. • 2 wire Horn/Strobe Sync mode allows audible
notification appliances (Horns) to besilenced while
visual notification appliances (Strobes) continue to
operate
• Horn/Strobe sync protocols include: Gentex,
System Sensor, Faraday, Wheelock and Amseco.
PRODUCT LISTINGS
• Temporal Code 3 Mode
• Steady Mode
California • Input to Output Follower Mode (maintains
3022852 State Fire synchronization of notification appliance circuits)
MEA •
Marshal March Time
NYC Department
• Compatible with 24VDC or 12VDC fire panels
S5694 of Building 7315-0410:171 • Input 115VAC
220-95-E Vol. 18 • AC fail, battery presence & low battery monitoring
• Accommodates up to two (2) 12VDC/12AH batteries
• Power supply, logic board, red enclosure, cam lock,
transformer & battery leads
Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F00105 05/2010
PE-6SN & PE-10SN - Power Extender

SPECIFICATIONS
PE-6SN:
• 24VDC rated @ 6 amps max
• Two (2) Class A or Four (4) Class B outputs
• Enclosure size of 16 3/4"H x 16 1/8"W x 3 1/2"D

PE-10SN:
• 24VDC rated @ 10 amps max
• Three (3) Class A or Six (6) Class B outputs
• Enclosure size of 16 3/4"H x 16 1/8"W x 3 1/2"D

STANDARD FEATURES
• 120/240 VAC 50/60 Hz Input
• PE-6SN offers 6 amps, PE-10SN offers 10 amps
• Two (2) Trouble Relays
DESCRIPTION • Two (2) Class A or B trigger circuit
• One (1) Programmable AUX power rated @ 3 amps
The PE-6SN and PE-10SN are voltage regulated • Quadrasync provides panel wide synchronization of
remote NAC Power Extenders. They may be con- the same or multiple brands
nected to any 24VDC Fire Alarm Control Panel • Pass Thru mode allows the Outputs to match the
(FACP). Primary applications include Notification Input Signal
Appliance Circuit (NAC) expansion (supports ADA • Signal Circuit Trouble Memory - Facilitates quickly
requirements) and will provide auxiliary power to locating intermittent system trouble and eliminates
support system accessories. The Power Extender costly and unneccessary service calls. LED's
offers an industry leading Quadrasync function that indicate a prior fault (short, open, ground) has
allows for multiple strobe circuits of different brands to occured on one or more signaling circuit outputs.
be synchronized to flash at the same time. The panel • Horn/Strobe sync protocols include: Gentex,
can have four different brands each connected to its System Sensor, Wheelock and Amseco/Potter.
own circuit and all of the strobes flash together in • Temporal Code 3 Mode
addition to the horns. • Configurable output circuits (DIP switch sets options
for each circuit)
• 15 mA at 8-33 VDC input trigger
• Reference EOL allows 2K-27K EOL value to be used
• AC fail, battery presence & low battery monitoring
PRODUCT LISTINGS • Supports 7 - 55AH batteries
• Accommodates up to two (2) 12VDC/18AH batteries
California • Power supply, logic board, red enclosure, cam lock
State Fire (CAT30), transformer & battery leads
Marshal

S5694 7315-0410:197

Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0136 12/2013
FNV-MP & FNV-DP Voice Evacuation System

SPECIFICATIONS
FNV-MP
Primary Power 120VAC @ 60Hz
220VAC @ 60Hz
Input Current 0.28 Amp @ 120VAC
Input Current 0.28 Amp (Typical Load 0.4
(Battery) Amp Maximum Load)
Batt. Charging 800 mA
Current
Batt. Size Minimum: 24VDC @ 7AH
Maximum: 24VDC @ 18AH
Batt. Type Two 12VDC Gel Cell (in series)
Dimensions 14.5"W x 27"H x 4"D
Color Red / Charcoal Gray
STANDARD FEATURES FNV-DP
Primary Power 120VAC @ 60Hz
• UL 864 9th Edition Listed 220VAC @ 60Hz
• True Multiplex 6 Channel Distributed Audio Input Current FNV-25 / 25E: 0.8 Amps @ 120VAC
• Integrated Fire Phone, Area of Rescue and Fan FNV-50 / 50E: 0.5 Amps @ 120VAC
& Damper Control capability FNV-100 / 100E: 1 Amps @ 120VAC
• Modular System - components added as needed Output Power FNV-25 / 25E: 25 Watts
• Integrated 2 Channel Digital Message Repeater FNV-50 / 50E: 50 Watts
• Live Microphone Page to any zone FNV-100 / 100E: 100 Watts
• Fast RS-485 Communication Protocol Freq. Response FNV-25 / 25E: 800 ~ 2800 Hz
• Fully Supervised FNV-50 / 50E: 400 ~ 4000 Hz
• Easy Installation and Operation FNV-100 / 100E: 400 ~ 4000 Hz
• Natural Voice Sound Recordings Output Voltage 25 / 70 Vrms Selectable
• Built-in Alarm and Alert Signals Input Current FNV-25 / 25E: 0.18 Amps / 1.1 Amps
• Up to 4 Minute Message Capacity (Battery) FNV-50 / 50E: 0.15 Amps / 1 Amps
• Works with 12VDC or 24VDC Fire Alarm Panels FNV-100 / 100E: 0.16 Amps / 1.1 Amps
• UL listed to be integrated with FireNET 2127/4127 Batt. Charging 800 mA
• 3 Minute Message Restart on Microphone Key Batt. Size Maximum: 24VDC @ 7AH
• Up to 256 Distributed Panels Maximum: 24VDC @ 18AH
Maximum: 24VDC @ 24AH
(FNV-DP100)
Batt. Type Two 12VDC Gel Cell (in series)
PRODUCT LISTINGS Dimensions 14.5"W x 27"H x 4"D
Color Red / Charcoal Gray
California
State Fire
Marshal
6911-0410:175
S5694

Specifications subject to change without notice Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0135 10/2011
DESCRIPTION
The Hochiki FNV High Rise Evacuation System operates in conjunction with the Fire Alarm Control Panel (FACP)
in a building to provide automatic response to life safety emergencies.

The Hochiki FNV includes all necessary features to provide an effective voice evacuation system. The Hochiki FNV
can be custom configured to satisfy the needs of any high rise application.

Fire department authorities can easily take command of evacuation or relocation procedures and emergencies.
Building management and fire brigades can monitor and control emergency response even before the
professionals arrive.

The FNV system includes capacity for 6 channels of simultaneous audio. This provides for evacuation, stay-in-
place, or other public address announcements and automatic messages.

Fire Fighter Phones or Warden Stations may be included as required. Area-of-Rescue stations can reassure
handicapped occupants that help is on the way. Smoke control, stair pressurization, and HVAC shutdown can be
completely automatic,unless controlled manually by management or fire authorities.

WIRING DIAGRAM

D is trib u te d P a n e l
Voice Evacuation
S p e a k e r Circuits
F
I
R
E

F
I
R
E
TB1
T B2 TB 1
T B2

T B3 T B3

Fire
FNV-25 FN V-25

FNV-50 FN V-50
FN V-100 FN V-100
Phone
L o c a l A u d io Amplifiers

F i re Phone
Circuit

N e tC o m m L o o p : U ns h ie ld e d T w is te d P a ir, S in g le pair
1 8 / 2 o r la rg e r, U n s h ie ld e d tw is t e d pair (U T P )
F P L , F P L R , F P L P run in conduit

D is trib u te d P a n el
Voice Evacuation
S p e a k e r Circuits
F
I
R
E

M a s te r P a n e l
H e a d E n d C o n tr o l
F
I
R
E
TB1 TB 1
T B2 T B2

PAG ING
CONTROL

FNV-25 FNV-25
FNV-50

FNV-10 0
FNV-50
Phone
FNV-10 0

L o c a l A u d io Amplifiers
F i re Phone
Circuit

F IR E P HO NE CONTROL

Hochiki America Corporation FNV-MP & FNV-DP Specifications subject to change without notice.
Description:
Fire Phone accessories give the FNV system two
VoiceNet
way communication capability. Fire Phone Equipment
Fire Phone jacks are mounted on a single gang plate.

Fixed telephone and warden stations are available in


Surface/Semi-Flush mount cabinet with a Thumb
Turn latch

FNV-FJ

Ordering Information:
Model Number Description

FNV-FJ Telephone Jack FNV-FH


Brushed Stainless Steel Single Gang
Plate

FNV-FH Portable Handset


Color - Red
(6 mount in FNV-TC cabinet)

FNV-TC Telephone Cabinet


Holds 6 FNV-FH Portable Handset
Cabinet: Charcoal Gray - std. -R Red
(Surface/Semi-Flush Mount / Key Lock
27 x 14-1/2 x 4” h-w-d)

FNV-FS Fire Phone Station


Coil cord / Thumb Turn Latch FNV-FS
Cabinet: Red FNV-TC
(Surface/Semi-Flush Mount
(Shown with 6 FNV-FH) FNV-WS
12-3/4 x 7-1/4 x 3-3/4” h-w-d)

FNV-WS Warden Station


Armored cable / Thumb Turn Latch
Cabinet: Red
(Surface/Semi-Flush Mount
12-3/4 x 7-1/4 x 3-3/4” h-w-d)

LISTED

7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 714.522.2246 www.hochiki.com
10K 1/2W
EOLR

Fire Phone Fire Phone


Handset Handset
Jack Jack

10K 1/2W
EOLR

Fire Phone Fire Phone


Handset Handset
Jack Jack

10K 1/2W
EOLR

Fire Phone Fire Phone


Handset Handset
Jack Jack

All Fire Phone


Circuits use
Twisted Pair 10K 1/2W
/

EOLR
#22 AWG min.
Fire Phone Fire Phone
Handset Handset
Jack Jack

10K 1/2W
EOLR

To Additional Fire Phone Fire Phone


Handset Handset

Fire Phone Circuits Jack Jack

(not shown)

1 2 3 4 1 2 3 4 1 2 3 4 1 2
TB1 TB2 TB3 TB
1 2 3 4

TB5
1 2 3 4

TB6
FPO Fire
1 2 3 4

Phone TB7
Loops
(Supervised)

MBR
/
10 Pin Ribbon Cable FPI
Cards plug into slots
available on MBR
First FPI allows 4 Fire Phone
Circuits off of MBR. Adding 2nd
FPI and an FPO allows 4
additional Fire Phone Circuits
(16 circuits max. in any FNV-DP)

7051 Village Drive, Suite 100


Buena Park, CA 90621-2268
EVAX - 25 Voice Evacuation System

STANDARD FEATURES

• Clean dead-front construction


• Digitally recorded automatic voice evacuation
(up to 4 minutes of message capacity)
• 25 Watt bullet-proof amplifier
• 25 or 70 VRMS field selectable
• 120 VAC power supply and battery charger
• Live microphone override of message and tone
• Analog addressable compatible
• High reliability, no maintenance, fully supervised
• Easy installation and operation
• Natural voice sound recordings
DESCRIPTION • Built-in alarm and alert signals
• Up to 4 minute message capacity
The EVAX 25 operates with any Fire Alarm Control • Works with 12VDC or 24VDC fire alarm panels
Panel (FACP), and provides 25 Watts of speaker • Works with analog/addressable and
power. microprocessor based fire alarm panels
• 3 minute message restart on microphone key
The EVAX 25 includes all necessary features to • 24 hour backup with two 12V 7 AHr batteries
provide an effective voice evacuation system. With • Made in the USA
the addition of zone splitters, remote microphone
panels, and expander modules, the EVAX 25 can be
custom configured to satisfy the needs of most
SPECIFICATIONS
applications. Primary Power 120VAC @ 0.8A

The EVAX 25 has its own power supply and battery 24 VDC Battery Power;
charger. Panel must be wired with 120 VAC and Standby 0.18A
standby batteries connected.
Alarm 1.00A
A digital message repeater (DMR) is built into the Output 25 Watts @ 25/70 VRMS
EVAX 25. The selection of alarm tone and automatic tone and voice
message repeats, as well as the 6 Hour delay of the Backbox Dimensions 14.5"W x 18"H x 4"D
AC power failure reporting feature are all field
configurable. Color Red/Charcoal Grey

The paging microphone is an integral component.


Removal of the microphone from the panel will cause PRODUCT LISTINGS
a "Trouble" condition which will be reported locally, as
well as through the FACP. California
State Fire
The EVAX 25 is housed in an attractive surface or Marshal
semi-flush mounted backbox, with a hinged and key 6911-0410:176
locked door. S5694

Continued on back.
Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0088 12/2012
ENGINEERING SPECIFICATIONS

The voice evacuation system shall be EVAX Systems Series EVAX 25 or approved equal.
The voice evacuation system shall provide 25 watts signal power and 25 watts voice power, and shall be UL listed.
The voice evacuation system shall be micro-processor based, and shall contain an integral microphone, 25-Watt
audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger.
The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until
fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return
to standby (normal operating) condition.
A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP
or from any normally open contact device.
Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone
(s) can be mounted up to 5000 feet away from the voice evacuation panel.

WIRING DIAGRAMS

Supervise - Power Limited Strobe Circuit


Fire NAC (Notification Appliance Circuit)
Alarm Supervise - Power Limited EOLR
Control F F
Panel NAC Voice Evacuation Speaker Circuit I I
R R
E E
Supervise - Power Limited
EOLR
120
VAC Class "A" Speaker Circuit if required

Power
Transformer*
*Power Transformer is
built into the EVAX 50

TB1 1 2 3 4 5 6 7 8
TB3 TB2
1 11
2 10
3 9
4 8
5 7
6 6
7 Trouble 5
4
8
3
Normal 2
1

Alarm
System Status LEDs

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

12 V - 12 V -
Battery Battery
+ +

ORDERING INFORMATION

Model Number Description


EVAX 25 25W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater
EVAX 25/4Z 25W Voice Evacuation System, with 4 Speaker Zone
EVAX 25/8Z 25W Voice Evacuation System, with 8 Speaker Zone

Hochiki America Corporation EVAX 25 Specifications subject to change without notice.


EVAX - 50 Voice Evacuation System
STANDARD FEATURES

• Clean dead-front construction


• Digitally recorded automatic voice evacuation
(up to 4 minutes of message capacity)
• 50 Watt high efficiency digital amplifier
• 25 or 70 VRMS field selectable
• 120 VAC power supply and battery charger
• Live microphone override of message and tone
• Analog addressable compatible
• High reliability, no maintenance, fully supervised
• Easy installation and operation
• Natural voice sound recordings
• Built-in alarm and alert signals
• Up to 4 minute message capacity
DESCRIPTION • Works with 12VDC or 24VDC fire alarm panels
• Works with analog/addressable and
The EVAX 50 operates with any Fire Alarm Control microprocessor based fire alarm panels
Panel
.
(FACP), and provides 50 Watts of speaker • 3 minute message restart on microphone key
power. • 24 hour backup with two 12V 7 AHr batteries
• Made in the USA
The EVAX 50 includes all necessary features to
provide an effective voice evacuation system. With
the addition of zone splitters, remote microphone
panels, and expander modules, the EVAX 50 can be SPECIFICATIONS
custom configured to satisfy the needs of most Primary Power 120VAC @ 0.6A
applications.
24 VDC Battery Power;
The EVAX 50 has its own power supply and battery Standby 0.130A
charger. Panel must be wired with 120 VAC and
standby batteries connected. Alarm 1.0A
Output 50 Watts @ 25/70 VRMS
A digital message repeater (DMR) is built into the tone and voice
EVAX 50. The selection of alarm tone and automatic
Backbox Dimensions 14.5"W x 18"H x 4"D
message repeats, as well as the 6 Hour delay of the
AC power failure reporting feature are all field Color Red/Charcoal Grey
configurable.

The paging microphone is an integral component.


Removal of the microphone from the panel will cause PRODUCT LISTINGS
a "Trouble" condition which will be reported locally, as
well as through the FACP. California
State Fire
The EVAX 50 is housed in an attractive surface or Marshal
semi-flush mounted backbox, with a hinged and key 6911-0410:176
S5694
locked door.
Continued on back.
Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0089 12/2012
ENGINEERING SPECIFICATIONS

The voice evacuation system shall be EVAX Systems Series EVAX 50 or approved equal.
The voice evacuation system shall provide 50 watts signal power and 50 watts voice power, and shall be UL listed.
The voice evacuation system shall be micro-processor based, and shall contain an integral microphone, 50 Watt
audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger.
The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until
fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return
to standby (normal operating) condition.
A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP
or from any normally open contact device.
Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone
(s) can be mounted up to 5000 feet away from the voice evacuation panel.

WIRING DIAGRAMS

Supervise - Power Limited Strobe Circuit


Fire NAC (Notification Appliance Circuit)
Alarm Supervise - Power Limited EOLR
Control F F
Panel NAC Voice Evacuation Speaker Circuit I I
R R
E E
Supervise - Power Limited
EOLR
120
VAC Class "A" Speaker Circuit if required

Power
Transformer*
*Power Transformer is
built into the EVAX 50

TB1 1 2 3 4 5 6 7 8
TB3 TB2
1 11
2 10
3 9
4 8
5 7
6 6
7 Trouble 5
4
8
3
Normal 2
1

Alarm
System Status LEDs

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

12 V - 12 V -
Battery Battery
+ +

ORDERING INFORMATION

Model Number Description


EVAX 50 50W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater
EVAX 50/4Z 50W Voice Evacuation System, with 4 speaker zones
EVAX 50/8Z 50W Voice Evacuation System, with 8 speaker zones

Hochiki America Corporation EVAX-50 Specifications subject to change without notice.


EVAX - 100 Voice Evacuation System
STANDARD FEATURES

• Clean dead-front construction


• Digitally recorded automatic voice evacuation
(up to 4 minutes of message capacity)
• 100 Watt high efficiency digital amplifier
• 25 or 70 VRMS field selectable
• 120 VAC power supply and battery charger
• Live microphone override of message and tone
• Analog addressable compatible
• High reliability, no maintenance, fully supervised
• Easy installation and operation
• Natural voice sound recordings
• Built-in alarm and alert signals
• Up to 4 minute message capacity
DESCRIPTION • Works with 12VDC or 24VDC fire alarm panels
• Works with analog/addressable and
The EVAX 100 operates with any Fire Alarm Control microprocessor based fire alarm panels
Panel
.
(FACP), and provides 100 Watts of speaker • 3 minute message restart on microphone key
power. • 24 hour backup with two 12V 7 AHr batteries
• Made in the USA
The EVAX 100 includes all necessary features to
provide an effective voice evacuation system. With
the addition of zone splitters, remote microphone
panels, and expander modules, the EVAX 100 can be SPECIFICATIONS
custom configured to satisfy the needs of most Primary Power 120VAC @ 2A
applications.
24 VDC Battery Power;
The EVAX 100 has its own power supply and battery Standby 0.180A
charger. Panel must be wired with 120 VAC and
standby batteries connected. Alarm 2.5A
Output 100 Watts @ 25/70 VRMS
A digital message repeater (DMR) is built into the tone and voice
EVAX 100. The selection of alarm tone and automatic
Backbox Dimensions 14.5"W x 18"H x 4"D
message repeats, as well as the 6 Hour delay of the
AC power failure reporting feature are all field Color Red/Charcoal Grey
configurable.

The paging microphone is an integral component.


Removal of the microphone from the panel will cause PRODUCT LISTINGS
a "Trouble" condition which will be reported locally, as
well as through the FACP. California
State Fire
The EVAX 100 is housed in an attractive surface or Marshal
semi-flush mounted backbox, with a hinged and key 6911-0410:176
S5694
locked door.
Continued on back.
Specifications subject to change without notice

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0090 03/2014
ENGINEERING SPECIFICATIONS
The voice evacuation system shall be EVAX Systems Series EVAX 100 or approved equal.
The voice evacuation system shall provide 100 watts signal power and 100 watts voice power, and shall be UL listed.
All speaker circuits shall be field selectable for 25 or 70 Vrms oepation and shall be power limited.
The voice evacuation system shall be micro-processor based, and shall contain an integral microphone, 100 Watt
audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger.
The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until
fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return to
standby (normal operating) condition.
A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP or
from any normally open contact device.
Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone (s)
can be mounted up to 5000 feet away from the voice evacuation panel.

WIRING DIAGRAMS

Supervise - Power Limited Strobe Circuit


Fire NAC (Notification Appliance Circuit)
Alarm Supervise - Power Limited EOLR
Control F F
Panel NAC Voice Evacuation Speaker Circuit I I
R R
E E
Supervise - Power Limited
EOLR
120
VAC Class "A" Speaker Circuit if required

Power
Transformer*
*Power Transformer is
built into the EVAX 50

TB1 1 2 3 4 5 6 7 8
TB3 TB2
1 11
2 10
3 9
4 8
5 7
6 6
7 Trouble 5
4
8
3
Normal 2
1

Alarm
System Status LEDs

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

12 V - 12 V -
Battery Battery
+ +

ORDERING INFORMATION
Model Number Description
EVAX 100 100W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater
EVAX 100/4Z 100W Voice Evacuation System, with 4 speaker zones
EVAX 100/8Z 100W Voice Evacuation System, with 8 speaker zones
EVAX 100/12Z 100W Voice Evacuation System, with 12 speaker zones, in a large cabinet
14.5"w x 27h" x 4"d
EVAX 100/16Z 100W Voice Evacuation System, with 16 speaker zones, in a large cabinet
14.5"w x 27h" x 4"d
Hochiki America Corporation EVAX-100 Specifications subject to change without notice.
EVAX - 150 & 200 Voice Evacuation System
STANDARD FEATURES
• Clean dead-front construction
• Digitally recorded automatic voice evacuation
(up to 4 minutes of message capacity)
• 50/100 Watt high efficiency digital amplifier
• 25 or 70 VRMS field selectable
• 120 VAC power supply and battery charger
• Live microphone override of message and tone
• Analog addressable compatible
• High reliability, no maintenance, fully supervised
• Easy installation and operation
• Natural voice sound recordings
• Built-in alarm and alert signals
• Up to 4 minute message capacity
• Works with 12VDC or 24VDC fire alarm panels
DESCRIPTION • Works with analog/addressable and
microprocessor based fire alarm panels
The EVAX 150/200 operates with any Fire Alarm • 3 minute message restart on microphone key
Control
.
Panel (FACP), and provides 150/200 Watts of • 24 hour backup with two 12V 7 AHr batteries
speaker power. • Made in the USA

The EVAX 150/200 includes all necessary features to SPECIFICATIONS


provide an effective voice evacuation system. With
the addition of zone splitters, remote microphone 100W Module:
panels, and expander modules, the EVAX 150/200
Primary Power 120VAC @ 2A
can be custom configured to satisfy the needs of
most applications. 24 VDC Battery Power 0.180A Standby
2.5A Alarm
The EVAX 150/200 has its own power supply and
Output 100 Watts @ 25/70 VRMS
battery charger. Panel must be wired with 120 VAC
and standby batteries connected. 50W Module:
Primary Power 120VAC @ 0.6A
A digital message repeater (DMR) is built into the
EVAX 150/200. The selection of alarm tone and 24VDC Battery Power 0.13A Standby
automatic message repeats, as well as the 6 Hour 1.0A Alarm
delay of the AC power failure reporting feature are all
Output 50 Watts @ 25/70 VRMS
field configurable.
Backbox Dimensions 14.5"W x 27"H x 4"D
The paging microphone is an integral component. Color Red/Charcoal Grey
Removal of the microphone from the panel will cause
a "Trouble" condition which will be reported locally, as
well as through the FACP. PRODUCT LISTINGS
California
The EVAX 150/200 is housed in an attractive surface
State Fire
or semi-flush mounted backbox, with a hinged and
Marshal
key locked door.
6911-0410:176
S5694
Specifications subject to change without notice Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0188 08/2013
ENGINEERING SPECIFICATIONS
The voice evacuation system shall be EVAX Systems Series EVAX 150/200 or approved equal.
The voice evacuation system shall provide 150/200 watts signal power and 150/200 watts voice power, and shall be
UL listed. All speaker circuits shall be field selectable for 25 or 70 Vrms oepation and shall be power limited.
The voice evacuation system shall be micro-processor based, and shall contain an integral microphone, 150/200
Watt audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger.
The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until
fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return to
standby (normal operating) condition.
A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP or
from any normally open contact device.
Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone (s)
can be mounted up to 5000 feet away from the voice evacuation panel.

WIRING DIAGRAMS

Fire Voice Evacuation Speaker Circuit


F
I
F
I
Alarm Supervise - Power Limited Supervise - Power Limited
R
E
R
E

Control EOLR
Panel NAC
Class "A" Speaker Circuit if required
F F
Voice Evacuation Speaker Circuit I I
R R
E E
Supervise - Power Limited
120 EOLR
VAC Class "A" Speaker Circuit if required

Pre-wired Trigger Circuit

TB1 1 2 3 4 5 6 7 8 TB1 1 2 3 4 5 6 7 8

TB3 TB2 TB3 TB2


1 11 1 11
2 10 2 10
3 9 3 9
4 8 4 8
5 7 5 7
6 6 6 6
7 Trouble 5 7 Trouble 5
4
8 4 8
3 3

Normal 2 Normal 2
1 1

Alarm Alarm
System Status LEDs System Status LEDs

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

12 V - 12 V -
Battery Battery
+ +

ORDERING INFORMATION
Model Number Description
EVAX 150 150W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater
EVAX 200 200W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater

Hochiki America Corporation EVAX-150 & 200 Specifications subject to change without notice.
HE Series Selectable Candela Evacuation Signals
STANDARD FEATURES
• Nominal voltage 12VDC and 24VDC
• 24VDC units have field selectable candela options
of 15, 30, 60, 75, and 110 candela
• 12VDC units have field selectable candela options of
15, 30, 60, and 75 candela
• Unit Dimensions: 5" high x 4.5" wide x 2.5" deep
• Synchronize strobe and/or horn with Hochiki Series
Control Module (12VDC product must use the
HAVSM Module)
• Prewire entire system, then install signals
• Lower installation and operating costs
• Input terminals supports 12 to 18 gauge wire
• Switch selection for high or low dBA
HEC/HES/HEH • Switch for chime, whoop, mechanical and 2400Hz
tone
• Switch for continuous or temporal 3 (not available on
APPLICATIONS whoop tone)
The HE Series is a low profile strobe and horn/strobe • Surface mount with the HSB (Hochiki surface
combination that offers dependable audible and visual mount box)
alarms and the lowest current available. • Silence horn while strobes remain flashing
• Wide voltage range 8-17.5VDC (12VDC units) 16-
The HE Series 24VDC offers tamperproof field select-
33VDC or FWR (24VDC units)
able candela options of 15, 30, 60, 75, and 110
• Faceplate available in red or off-white
candela.
The 12VDC models offers tamperproof field selectable
candela options of 15, 30, 60, and 75 candela. The
PRODUCT LISTINGS
HE Series horn offers a continuous or synchable California State
temporal three in 2400Hz and mechanical tone, a Fire Marshal
chime and whoop tone. All tones are easy for the
professional to change in the field by using switches.
• UL 464 & UL 1971 Listed - S8369
The HE Series has a minimal operation current and • CSFM Listed - 7135-0410:0187, 7135-0410:0188
has a minimum flash rate of 1Hz regardless of input
voltage. Product Compliance
The HE Series is shipped with the standard 4" metal • NFPA 72
mounting plate which incorporates the popular Slide • Americans with Disabilities Act (ADA)
feature that allows the installer to easily test for
supervision. The product also features a locking
mechanism which secures the product to the bracket
without any screws showing.
The HE Series appliances are UL 464 and UL 1971
listed for use with fire protective systems and are
warranted for three years from date of purchase.

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0103 11/2013
HEH 12VDC or 24VDC Low Profile Evacuation Horn
Model Number Part Number Nominal Reverberant dBA In Anechoic Room
Voltage @ 10ft., per UL 464 dBA @10ft.
HEH24-WR 0500-05880 24VDC 62-82 100
HEH24-WW 0500-05890 24VDC 62-82 100

HES3 12VDC or 24VDC Selectable Candela Low Profile Evacuation Strobe


Model Part Nominal Candela
Number Number Voltage (UL 1971)
HES3-12WR 0500-05900 12 VDC 15, 30, 60, 75 Model Designations:
HES3-12WW 0500-05910 12 VDC 15, 30, 60, 75 W = Wall mount R = Red faceplateW = Off-white
HES3-12PWR 12 0500-05920 12 VDC 15, 30, 60, 75 faceplateP = Plain (no lettering)
HES3-12PWW 0500-05930 12 VDC 15, 30, 60, 75
ALERT bezel available
HES3-24WR 0500-05940 24 VDC 15, 30, 60, 75, 110
AGENT bezel available.
HES3-24WW 0500-05950 24 VDC 15, 30, 60, 75, 110
HES3-24PWR 0500-05960 24 VDC 15, 30, 60, 75, 110
HES3-24PWW 0500-05970 24 VDC 15, 30, 60, 75, 110
HEC3 12VDC or 24VDC Selectable Candela Low Profile Evacuation Horn/Strobe
Model Part Nominal Candela Reverberant dba @ In Anechoic Room
Number Number Voltage (UL 1971) 10ft., per UL 464 dBA @ 10ft.
HEC3-12WR 0500-05980 12 VDC 15, 30, 60, 75 62-82 100
HEC3-12WW 0500-05990 12 VDC 15, 30, 60, 75 62-82 100
HEC3-12PWR 0500-06000 12 VDC 15, 30, 60, 75 62-82 100
HEC3-12PWW 0500-06010 12 VDC 15, 30, 60, 75 62-82 100
HEC3-24WR 0500-06020 24 VDC 15, 30, 60, 75, 110 62-82 100
HEC3-24WW 0500-06030 24 VDC 15, 30, 60, 75, 110 62-82 100
HEC3-24PWR 0500-06040 24 VDC 15, 30, 60, 75, 110 62-82 100
HEC3-24PWW 0500-06050 24 VDC 15, 30, 60, 75, 110 62-82 100
HE3-12 Product Strobe Current Ratings HE3-24 Product Strobe Current Ratings
Candela 15cd 30cd 60cd 75cd Candela 15cd 30cd 60cd 75cd 110cd
12VDC 106mA 131mA 186mA 237mA 24VDC 30mA 35mA 66mA 80mA 103mA
UL Max 92mA 141mA 260mA 312mA UL Max 42mA 58mA 97mA 116mA 161mA
HE3-12 Product Horn Current Ratings NOTES:
Horn Mode Minimum dBA • Operating temperature: 32°to 120°F (0°
Minimum dBA Regulated 12VDC
@ 10ft., per to 49° C). The HE Series is not listed for
@ 10ft., per Max. Operating @
UL 464 (HIGH) outdoor use.
UL 464 (LOW) High Setting (mA)
Temp 3 2400Hz 76 • The sound output for the temporal 3
69* 29
Temp 3 Mechanical 75 tone is rated lower since the time the horn
68* 26
Temp 3 Chime 62* is off is averaged into the sound output
60* 13
Continuous 2400Hz 79 rating. While the horn is producing a tone
74* 29
Continuous Mechanical 78 in the temporal 3 mode its sound pressure
72* 26
Continuous Chime 63* is the same as the continuous mode.
61* 13
Whoop 78 • For nominal and peak current across UL
71* 55
regulated voltage range for filtered DC
HE3-24 Product Horn Current Ratings power and unfiltered (FWR [Full Wave
Horn Mode Minimum dBA Minimum dBA Regulated 24VDC Rectified]) power, see installation manual.
@ 10ft., per @ 10ft., per Max. Operating @ 12VDC models are DC only.
UL 464 (HIGH) UL 464 (LOW) High Setting (mA) • Hochiki does not recommend using a
Temp 3 2400Hz 78 71* 28 coded or pulsing signaling circuit with any
Temp 3 Mechanical 76 70* 25 of our strobe products (see Technical
Temp 3 Chime 70* 66* 15 Bulletin 014).
Continuous 2400Hz 81 74* 28
Continuous Mechanical 80 72* 25
Continuous Chime 70* 66* 15
Whoop 82 69* 56
*Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level
required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use.
Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always
private mode).
1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the
listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is
usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is
usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual.
Hochiki America Corporation HE Series Selectable Candela Evacuation Sginals
Specifications subject to change without notice.
HC Series Selectable Ceiling Mount
Strobe and Horn Strobe

STANDARD FEATURES
• Nominal Voltage 24 VDC
• Tamperproof Field Selectable candela options of 15,
30, 75, 95,115 & 150
• Unit Dimensions: 6" x 2.6"
• Synchronize HC Series by using Hochiki America
Series Control Module
• Input Terminals support 12 to 18 AWG
• Switch Selection for High or Low dBA
• Switch Selection for 2400Hz or Mechanical Tone
• Switch Selection for Continuous or Temporal 3
• Tamperproof Re-entrant Grill
HCS/HCC 24VDC SERIES
• Surface Mount with the HCSB (Hochiki Ceiling
Surface Mount Box)
APPLICATIONS • Silence Horn While Strobes Remain Flashing
• Wide Voltage Range 16-33 VDC or FWR
The HC Series is a ceiling mount strobe or horn/strobe • Faceplate Available in Red or Off-White
combination that offers dependable audible and visual
alarms and the lowest current available.
PRODUCT LISTINGS
The HC Series offers tamperproof field selectable
candela options of 15, 30, 75, 95, 115 and 150 California State
Fire Marshal
candela.
The HC Series horn offers a pattern or synchable
temporal 3 in 2400Hz or mechanical tone. These tones
• UL 464 & UL 1971 Listed - S8369 & S3597
are easy for the technician to change in the field by
• CSFM Listed - 7125-0410:0187, 7125-0410:0188
using switches.
The HC Series has a minimal operating current and a Product Compliance
minimum flash rate of 1Hz regardless of input voltage. • NFPA 72
The HC Series comes standard with the 4" mounting • Americans with Disabilities Act (ADA)
plate which incorporates the popular Super-Slide®
feature that allows the installer to easily test for
supervision.
The HC Series appliances are UL 464 and UL 1971
listed for use with fire protective systems.

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0100 08/2011
HCS Series 24 Volt Ceiling Mount Selectable Strobe
Model Number Part Number Nominal Voltage Candela
HCS24CR 0500-05060 24VDC 15, 30, 75, 95, 115, 150
HCS24CW 0500-05070 24VDC 15, 30, 75, 95, 115, 150
HCS24PCR 0500-06080 24VDC 15, 30, 75, 95, 115, 150
HCS24PCW 0500-06090 24VDC 15, 30, 75, 95, 115, 150

HCC Series 24 Volt Ceiling Mount Selectable Horn/Strobe


Model Number Part Number Nominal Candela Reverberant In Anechoic
Voltage dBA @ 10ft. Room dBA
Per UL 464 @10ft.
HCC24CR 0500-06100 24 VDC 15, 30, 75, 95, 115, 150 81-86 90
HCC24CW 0500-06110 24 VDC 15, 30, 75, 95, 115, 150 81-86 90
HCC24PCR 0500-06120 24VDC 15, 30, 75, 95, 115, 150 81-86 90
HCC24PCW 0500-06130 24VDC 15, 30, 75, 95, 115, 150 81-86 90

Notes:
• The HC Series is not listed for outdoor use.
• Operating temperature: 32°to 120°F (0° to 49° C)
• For nominal and peak current across UL regulated voltage range for filtered DC
power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual.
• Hochiki does not recommend using a coded or pulsing signaling circuit with any
of our strobe products (see technical bulletin number 014 for more information).

Model designations:
”P” = Plain (no lettering) “C” = Ceiling Mount, “R” = Red Faceplate/”W” = Off-White Faceplate

HC Series Product Strobe Current Ratings


Candela 15cd 30cd 75cd 95cd 115cd 150cd
24 VDC 72mA 101mA 167mA 200mA 214mA 286mA
2
UL Max 120mA 120mA 200mA 220mA 290mA 321mA

Horn Mode Minimum dBA Minimum dBA Regulated 24VDC


@ 10ft. per @ 10ft. per Max. Operating
UL464 (HIGH) UL464 (LOW) @ High Setting (mA)
Temp 3 2400Hz 83 75 23
Temp 3 Mechanical 81 73* 22
Continuous 2400Hz 86 78 23
Continuous Mechanical 84 76 22

*Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level
required for public mode fire protection service. These settings are acceptable only for private mode fire alarm
use. Use the high dBA setting for public mode application.
Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the
sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same
as the continuous mode.
To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw.

2
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within
the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum
listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage.
For unfiltered FWR ratings, see installation manual.

Hochiki America Corporation HC Series Selectable Ceiling Mount Strobe and Horn Strobe Specifications subject to change without notice.
HGOE-R / HGOE-W Outdoor Enclosure

SPECIFICATIONS
Models HGOE-R, HGOE-W
Dimension 4.75”W x 5.75”H x 4.18”D
Conduit Knockouts 0.75”
Colors Red or Off-White

STANDARD FEATURES
• Weatherproof seal
• Made of Clear Lexan® - providing maximum visibility
and reliability for effective visible signaling
• UV Stable Polycarbonate Lens
• Back-box or side mount with mounting tabs
HGOE-R/HGOE-W • Reinforcement Steel Hardware
• Textured plastic Finish
• Available in red or off-white
APPLICATIONS
The HGOE-R and HGOE-W are UL listed for outdoor
use with the HEH, HES and the WHE Series Strobe
and horn/strobe.

FRONT AND SIDE VIEW

PRODUCT LISTINGS
California State
Fire Marshal

• UL 464 & UL 1971 Listed - S3597


• CSFM Listed - 7300-0410:0189

Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0126 06/2013
HBLP, HSB & HCSB Series Back Box

HCSB-R/HCSB-W HSB-R/HSB-W

HBLP-R/HBLP-W

STANDARD FEATURES SPECIFICATIONS


• Weatherproof seal HCSB-R, HCSB-W:
• Back-box or side mount with mounting tabs Dimensions 6.2" round x 1.67" D
• Reinforcement steel hardware Colors Red or Off-White
• Textured plastic finish HSB-R, HSB-W:
• Available in red or off-white Dimensions 5.57" H x 4.55" W x 1.47" D
Colors Red or Off-White
APPLICATIONS HBLP-R, HBLP-W:
The HCSB Series surface back box is constructed of Dimensions 6.1" square x 4.06" D
durable plastic and is fully compatible with the HC Colors Red or Off-White
Series strobes and horn/strobes.
The HSB Series surface back box is constructed of PRODUCT LISTINGS
durable plastic and is fully compatible with the HE
Series horns, strobes, and horn/strobes. California State
Fire Marshal
The HBLP Series surface back box is constructed of Pending
durable plastic and is fully compatible with the
HSSPK Series speakers and speaker/strobes • UL 464 & UL 1971 Listed - S1529 & S8370

Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0128 11/2013
HAVSM SYNCHRONIZATION CONTROL MODULE

STANDARD FEATURES
• Synchronize Horn and Strobe with the use of only
two wires
• Module is Rated for 3 Amps Continuous Current
and 5 Amps Surge or Inrush Current
• Synchronizes to 1Hz Flash Rate
• Operates 1 "Class A" circuit or 2 "Class B" circuits
at 3 Amps per Circuit
• Dual Synchronization Module Only when Using
"Class B" circuits
• A Green LED status indicator
• Option to Silence the Horn while Strobes continue
to Flash when using Temporal 3 Mode
• HAVSM Operates the HCS/HCC, HES3-24/HEC3-
HAVSM 24, HES3-12/HEC3-12, HEC/HES/HEH, HSSPK
Series and HX93 Series.
• HAVS module come with its own back box and
cover plate
APPLICATIONS • Dimensions of Module: 3.85"H x 3.82"W x 1.32"D
• Dimensions of Box: 5.57"H x 4.55"W x 2.39"D
The HAVSM control modules are designed to provide • Available in Fire Alarm Red or Off-White.
an easy way to synchronize multiple horns as well as
strobe light flashes using only two wires in instances
where a synchronized flash is required. HAVSM SYNC CONTROL MODULE
When the module is in temporal 3 mode, it has the Model Part
cabability to synchronize multiple horn signals and Number Number
the ability to silence the horn while allowing the HAVSM-R 0500-06340
strobes to continue to flash. In unison mode, the horn HAVSM-W 0500-06350
cannot be silenced while maintaining strobe operation.

Model Designations:
R = Red faceplate W = Off-white faceplate
Operating temperature - Indoor Use Only
Indoor: 32°to 120°F (0° to 49° C)

PRODUCT LISTINGS HAVSM Current Ratings


12VDC 27mA
California State
Fire Marshal
12VDC UL Max 31mA
24VDC 37mA
24VDC UL Max 45mA
• UL 464 & UL 1971 Listed - S8369
• CSFM Listed - 7125-0410:0188

Product Compliance
• NFPA 72
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0131 09/2011
HSSPKCLP Series Ceiling Mount Speaker/Strobe

STANDARD FEATURES

• Nominal Voltage 24 VDC


• Tamperproof Field Selectable candela options of 15,
30, 75, 95 & 115
• Speaker only models can be wall or ceiling mounted
• Unit Dimensions: 6.1" x 1.88"
• Synchronize HSSPKCLP Series by using Hochiki
America Series HAVSM Synchronization Module
• High Quality dBA Output
• Frequency Range 400-4000Hz
• Input Terminals supports 12 to 18 AWG
HSSPKCLP SERIES • Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W,
2W and 4W
• Field Selectable Speaker Voltage 25 or 70.7 VRMS
Standard
APPLICATIONS • Tamperproof Grill
• Strobe maintains constant flash rate (1Hz)
The HSSPKCLP Series are ceiling mount, selectable regardless of input voltage
candela speaker/strobes designed to meet code • Faceplate Available in Red or Off-White
requirement for audio, visual and voice
communications. The HSSPKCLP Series are quality
speaker products that offer both dependable evacuation
signaling and visual alarms, or a combination of both.
The high output tamperproof candela selections are 15,
30, 75, 95 and 115.
The HSSPKCLP Series can be mounted in a 4" square
x 2-1/8" deep back box. An extension ring is not
needed.
The HSSPKCLP Series strobes can be synchronized
by using the HAVSM Synchronization Module.

PRODUCT LISTINGS
California State
Fire Marshal

• UL 1480, UL 1638 & UL 1971 Listed - S8370


• CSFM Listed - 7320-0410:0194

Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0133 07/2014
HSSPKCLP Series
Model Number Part Number Desciption Nominal Voltage
HSSPK24CLPR 0500-06280 Speaker/Strobe 24VDC
HSSPK24CLPW 0500-06290 Speaker/Strobe 24VDC
HSSPK24CLPPR 0500-06260 Speaker/Strobe 24VDC
HSSPK24CLPPW 0500-06270 Speaker/Strobe 24VDC
HSSPKCLPR 0500-06300 Speaker N/A
HSSPKCLPW 0500-06310 Speaker N/A

Notes:
• The HSSPKCLP Series is not listed for outdoor use
• Operating temperature: 32° to 120° F (0° to 49° C)

Model designations:
”P” = Plain (no lettering), “R” = Red Faceplate, ”W” = Off-White Faceplate

Low Profile Speaker dBA @ 10 ft.


Input Watts 25 Volts 70.7 Volts
1/8 74.6 dBA 73.7 dBA
1/4 77.7 dBA 76.7 dBA
1/2 80.5 dBA 79.6 dBA
1 83.1 dBA 82.5 dBA
2 85.6 dBA 85.4 dBA
4 87.9 dBA 87.9 dBA

HSSPKCLP Series Strobe Current Ratings


Candela 15cd 30cd 75cd 95cd 115cd
24 VDC 72mA 88mA 176mA 200mA 214mA
1
UL Max 120mA 120mA 272mA 318mA 360mA

1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within
the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum
listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage.
For unfiltered FWR ratings, see installation manual.

Hochiki America Corporation HSSPKCLP Series Ceiling Mount Speaker/Strobe Specifications subject to change without notice.
HSSPKWLP Series Wall Mount Speaker/Strobe

STANDARD FEATURES

• Nominal Voltage 24 VDC


• Tamperproof Field Selectable candela options of 15,
30, 60, 75, 110 & Fixed 15/75
• Unit Dimensions: 6.1" x 1.88"
• Synchronize HSSPKWLP Series by using Hochiki
America HAVSM Synchronization Module
• High Quality dBA Output
• Frequency Range 400-4000Hz
• Input Terminals supports 12 to 18 AWG
HSSPKWLP SERIES
• Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W,
2W and 4W
• Field Selectable Speaker Voltage 25 or 70.7 VRMS
Standard
APPLICATIONS • Tamperproof Grill
• Strobe maintains constant flash rate (1Hz)
The HSSPKWLP Series are wall mount, selectable regardless of input voltage
candela speaker/strobes designed to meet code • Faceplate Available in Red or Off-White
requirement for audio, visual and voice
communications. The HSSPKWLP Series are quality
speaker products that offer both dependable evacuation
signaling and visual alarms, or a combination of both.
The high output tamperproof candela selections are 15,
30, 60, 75, and 110. A fixed 15/75 candela unit is also
available.
The HSSPKWLP Series can be mounted in a 4"
square x 2-1/8" deep back box. An extension ring is
not needed.
The HSSPKWLP Series strobes can be synchronized
by using the HAVSM Synchronization Module.

PRODUCT LISTINGS
California State
Fire Marshal

• UL 1480, UL 1638 & UL 1971 Listed - S8370


• CSFM Listed - 7320-0410:0195

Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0132 07/2014
HSSPKWLP Series
Model Number Part Number Nominal Voltage
HSSPK24WLPR 0500-06240 24VDC
HSSPK24WLPW 0500-06250 24VDC
HSSPK24WLPPR 0500-06230 24VDC
HSSPK24WLPPW 0500-06220 24VDC
HSSPK24-15/75WLPR 0500-06200 24VDC
HSSPK24-15/75WLPW 0500-06210 24VDC
HSSPK24-15/75WLPPR 0500-06190 24VDC
HSSPK24-15/75WLPPW 0500-06180 24VDC

Notes:
• The HSSPKWLP Series is not listed for outdoor use
• Operating temperature: 32° to 120° F (0° to 49° C)

Model designations:
”P” = Plain (no lettering), “R” = Red Faceplate, ”W” = Off-White Faceplate

Low Profile Speaker dBA @ 10 ft.


Input Watts 25 Volts 70.7 Volts
1/8 74.6 dBA 73.7 dBA
1/4 77.7 dBA 76.7 dBA
1/2 80.5 dBA 79.6 dBA
1 83.1 dBA 82.5 dBA
2 85.6 dBA 85.4 dBA
4 87.9 dBA 87.9 dBA

HSSPKWLP Series Strobe Current Ratings


Candela 15cd 30cd 60cd 75cd 110cd 15/75cd
24 VDC 33mA 63mA 88mA 112mA 136mA 63mA
1
UL Max 78mA 96mA 137mA 180mA 224mA 96mA

1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within
the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum
listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage.
For unfiltered FWR ratings, see installation manual.

Hochiki America Corporation HSSPKWLP Series Wall Mount Speaker/Strobe Specifications subject to change without notice.
HX93 Series Mini-Horn

STANDARD FEATURES
• Nominal voltage 12VDC and 24VDC
• Jumper for Selectable Temporal 3 or Continuous
tone
• Horn Frequency of 3100Hz
• Input terminals supports 12 to 18 gauge wire
• Low Current Consumption
• Textured Finish High Impact Plastic Faceplate
• Available in Fire Alarm Red or Off-White.

HX93 Series Mini-Horn


Model Part
Number Number
HX93-R 0500-06160
HX93 SERIES HX93-W 0500-06170

APPLICATIONS NOTES: The sound output for the temporal 3 tone is


The HX93 Series mini-horn is a high quality remote rated lower since the time the horn is off is averaged into
signaling appliance that offers dependable remote the sound output rating. While the horn is producing a
annunciation. The HX93 is listed for use with both tone in the temporal 3 mode its sound pressure is the
filtered and unfiltered power. same as the continuous mode.
The HX93 a jumper is provided to select either the
continuous tone or the temporal 3 evacuation tone.
Model Designations:
The HX93 can be used on the same sync circuit R = Red faceplate W = Off-white faceplate
(HAVSM Series Sync Module) as other HA Signals.
Operating temperature - Indoor Use Only
The HX93 appliances are UL 464 listed for use with
Indoor: 32°to 120°F (0° to 49° C)
fire protective systems.

HX93 Current Ratings


Product HX93
PRODUCT LISTINGS 24VDC 18mA
California State 24VFWR 20mA
Fire Marshal 12VDC 13mA
12VFWR 17mA

• UL 464 Listed - S3597


• CSFM Listed - 7135-0410:0190 Horn Mode Minimum dBA Minimum dBA
@ 10ft., per @ 10ft., per
Product Compliance UL 464 @ 24V UL 464 12V
• NFPA 72 Temporal 3 81 78
Continuous 86 83

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0129 06/2012
WHE Series Weatherproof Evacuation Signals

STANDARD FEATURES

• Nominal voltage 24VDC


• Unit is shipped with WHES24-75 Candela Strobe or
WHEC24-75 Candela Horn/Strobe
• Unit Dimensions: HGOE 5.75" High x 4.75" Wide x
4.18" Deep
• Switch Selection for High dBA
• Switch for Mechanical and 2400hz Tone
• Switch for Continuous Tone
• Input terminals supports 12 to 18 gauge wire
• Tamperproof Re-entrant Grill
WHE SERIES • Wide Voltage Range of 16-33 VDC or FWR
• Separate Horn and Strobe Functions
• Synchronize Strobe and/or Horn by using HAVSM
Module
APPLICATIONS • Faceplate available in Red or Off-White

The WHE Series offers dependable visible and/or


audible alarms for all outdoor needs.
Included with the WHE Series is the HGOE outdoor
enclosure. The enclosure provides protection from
weather related conditions and allows the necessary
full candela output. This highly constructed enclosure
meets various installation requirements including
deterring moisture from entering the enclosure.
The WHE Series is equipped with a 4" mounting plate
which incorporates the sliding feature that allows the
installer to easily test for supervision. The product
also features a locking mechanism which secures the
product to the bracket without any screws showing.
The WHE Series has a minimal operation current and
has a minimum flash rate of 1Hz and can vary up to
2Hz regardless of input voltage.
PRODUCT LISTINGS
California State
Fire Marshal

• UL 464 & UL 1638 Listed - S3597


• CSFM Listed - 7135-0410:0187

Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0134 08/2011
WHES24 Weatherproof Low Profile Evacuation Strobe
Model Part Nominal Candela Model Designations:
Number Number Voltage (UL 1971) W = Wall mount R = Red faceplate W = Off-white
WHES24-75WR 0500-05780 24 VDC 75
WHES24-75WW 0500-05790 24 VDC 75 WHES24 and WHEC24 are shipped with HOE
Enclosure

WHEC24 Weatherproof Low Profile Evacuation Horn/Strobe


Model Part Nominal Candela Reverberant dba @ In Anechoic Room
Number Number Voltage (UL 1971) 10ft., per UL 464 dBA @ 10ft.
WHEC24-75WR 0500-05860 24VDC 75 70-82 100
WHEC24-5WW 0500-05870 24VDC 75 70-82 100

NOTES:
• The HES Series is listed for outdoor use.
Indoor Operating temperature: 32°to 120°F (0° to 49° C)
Outdoor Operating Temperature: -31°to 150°F (-35° to 66° C)

WHE Series Product Strobe Current Ratings


Candela 75cd
12VDC 112mA
UL Max1 180mA

WHE Series Product Horn Current Ratings


Horn Mode Minimum dBA Minimum dBA Regulated 12VDC
@ 10ft., per @ 10ft., per Max. Operating @
UL 464 (HIGH) UL 464 (LOW) High Setting (mA)
Temp 3 2400Hz 78 71* 28
Temp 3 Mechanical 76 70* 25
Temp 3 Chime 70* 66* 15
Continuous 2400Hz 81 74* 28
Continuous Mechanical 80 72* 25
Continuous Chime 70* 66* 15
Whoop 82 69* 56

*Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level
required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use.
Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always
private mode).

Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound
output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous
mode.

1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the
listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage
(16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR
ratings, see installation manual.

Hochiki America Corporation WHE Series Weatherproof Evacuation Sginals


Specifications subject to change without notice.
HEP & HEPS Series
Colored Lens Expander Plate Strobe
STANDARD FEATURES
• Nominal Voltage 24 VDC
• Lens colors available: amber, blue, green and red
• Amber lens models have field selectable candela
options: 15, 30, 60, 75 and 110
• Blue, green and red lens models are fixed 15/75
candela
• HEP Dimensions: 10.8" H x 6.6" W x 2.8" D
• HEPS Dimensions: 11.5" H x 7.26" W x 5.04" D
• ALERT text on all units
• Wall mount to a standard 4" square x 2.125 deep
Shown without speaker/strobe Shown with speaker/strobe back box
• HEPS can accommodate 1/2" and 3/4" conduit
APPLICATIONS • Input terminals support 12 to 18 AWG
• Use in conjuction with Hochiki's speaker or wall
The HEP and HEPS Series is a wall mount expander mount speaker/strobe (SOLD SEPARATELY)
plate with a quality colored lens strobe to be used in • To synchronize use the HAVSM control module
conjunction with a Hochiki speaker or wall mount • Wire strip guide
speaker/strobe. It is designed to allow the ability to • Faceplate available in off-white
mount multiple strobes on a single electrical box. • Xenon strobe maintains constant flash rate of or at
Applications include emergency communication, 1Hz
severe weather, evacuation, emergency response and
many more.

The HEP Series is to be used in flush mount


applications and the HEPS Series is to be used in
surface mount applications. The HEP and HEPS
Series strobes are designed to be used on a 24VDC
system and are available in amber, blue, green
and red lens colors. The amber lens units are provided
with a turn dial for field selectable candela options. The
blue, green and red lens units are available in a fixed
15/75 candela option. The strobes can be PRODUCT LISTINGS
synchronized by using the HAVSM Control Module, as
California State
well as FACP or power supplies that include the Fire Marshal
Gentex Synchronization Protocol. All units feature
ALERT text on the colored lens.
• UL 1480, UL 1638 & UL 1971 Listed - E366065
The HEP and HEPS Series is constructed of high • CSFM Listed - 7300-0410:0208
impact textured plastic. The Series is warranted for 3
years from the date of purchase and is ANSI/UL 1638 Product Compliance
Listed. The amber lens units additionally comply with • NFPA 72
the light output dispersion requirements of ANSI/UL • IBC/IFC/IRC
1971 for wall mount applications with a measured • City & State Ordinances/Laws/regulations
candela rating that is equal to the candela listed on the
product. Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0190 01/2014
HEP Series Flush Mount Expander Plate
Model # Part # Lens Color Nominal Voltage Candela(s)
HEPA 0500-06900 Amber 24VDC 15, 30, 60, 75, 110
HEPB 0500-06910 Blue 24VDC Fixed 15/75
HEPG 0500-06920 Green 24VDC Fixed 15/75
HEPR 0500-06930 Red 24VDC Fixed 15/75

HEPS Series Surface Mount Expander Plate


Model # Part # Lens Color Nominal Voltage Candela(s)
HEPAS 0500-06940 Amber 24VDC 15, 30, 60, 75, 110
HEPBS 0500-06950 Blue 24VDC Fixed 15/75
HEPGS 0500-06970 Green 24VDC Fixed 15/75
HEPRS 0500-06980 Red 24VDC Fixed 15/75

Model Designations: NOTES:


• All models are designed for wall mount applications
• All models available in white faceplate • Operating temperature 32° to 120°F (0° to
• All models include ALERT text 49°C).
Lens Colors: A = Amber B = Blue G = Green R = Red • The HEP/HEPS series is listed for indoor
use only.
HEP/HEPS Amber Lens Strobe Current Ratings • For nominal and peak current across ANSI/UL
Candela UL Max. Operating Current (mA) regulated voltage range for filtered DC power
15 78 and unfiltered full wave rectified power, see
30 96 installation manual.
60 137 • Hochiki does not recommend using a coded or
75 180 pulsing signaling circuit with any of our strobe
110 224 products.
• The HEP/HEPS series is not to be used as a
visual public mode alarm notification appliance.
HEP/HEPS Other Lens Strobe Current Ratings • RMS current ratings are per ANSI/UL average
Fixed 15/75* Candela Strobe RMS method. ANSI/UL max current rating is
Lens Color UL Max. Operating Current (mA) the maximum RMS current within the listed
Blue 280 voltage range (16-33VDC for 24VDC units). For
strobes the UL max current is usually at the
Green 360
minimum listed voltage (16VDC for 24VDC
Red 397
units). For unfiltered full wave rectified rating,
* The HEPB, HEPG, HEPR, HEPBS, HEPGS, HEPRS see installation manual.
have a fixed candela rating of 15/75 per ANSI/UL 1638

HEP/HEPS Amber Lens Strobe Candela Ratings


Candela ANSI/UL 1638 On-Axis ANSI/UL 1971 Measured
Candela Rating Candela Rating, Wall Mount
15 15 15
30 30 30
60 60 60
75 75 75
110 110 110
Notice: Per NFPA 72, colored strobes are to be listed to ANSI/UL 1638. ANSI/UL 1971 is
not applicable to colored lens devices used in emergency communication installations.
However, the listed readings were obtained using the light output dispersion measurement
requirements under ANSI/UL 1971.

Hochiki America Corporation HEP/HEPS Series Specifications subject to change without notice.
HHLF SERIES - LOW FREQUENCY AUDIBLE SIGNAL
STANDARD FEATURES
 Nominal voltage 24 VDC
 Unit Dimensions: 6-1/8” (15.55 cm) high x 5-
1/2” (13.97 cm) wide x 1-5/8” (4.13 cm) deep
 Synchronize horn with Hochiki HTSM Synchroniza-
tion Control Module
 Prewire entire system, install mounting bracket, then
install signals
 Input terminals accept 12 to 18 AWG

APPLICATIONS  Produces a 520Hz square wave, temporal 3 tone

The HHLF is a high quality, low profile, low frequency  Jumper selection for normal or loud dBA
audible appliance that offers a dependable audible  Temporal 4 pattern available when used with Hochiki
alarm with a low current draw. The HHLF is ideal for HTSM Synchronization Module
any occupancy that requires notification appliances.
 Temporal 4 520Hz measured per ANSI/UL 2075
The HHLF horn offers a 520 Hz square wave, temporal
 Tamperproof re-entrant style grill and locking screw
3 tone. A jumper selection is available for normal or (optional use)
loud decibel tone. A temporal 4 pattern is available
when used with the Hochiki HTSM Synchronization  Faceplate available in red or off-white
Control Module.
The HHLF is shipped with a standard 4" metal mounting PRODUCT COMPLIANCE
plate. The product also features a locking mechanism
 NFPA 72
which secures the product to the bracket without any
screws showing.  IBC/IFC/IRC
The HHLF horn is listed to ANSI/UL 464 and CAN/ULC Model Number Part Number Nominal Voltage
S3597, is listed for use with fire protective systems and
HHLFW 0500-07450 24 VDC
is warranted for three years from date of purchase.
HHLFR 0500-07460 24 VDC

PRODUCT LISTINGS
MODEL DESIGNATIONS:
W = White Faceplate
California State
R = Red Faceplate
Fire Marshal
All units are plain (no lettering)
Pending
S3597

Horn Decibel Levels: 24 VDC Nominal Horn Horn Current Ratings


Reverberant Room Current Ratings (mA) Over Input Voltage Range of 16-33V (mA)

Regulated Regulated Regulated Regulated


Minimum SPL Minimum SPL 24 VDC 24VDC 24VFWR 24VFWR
24VDC Max. 24VDC Max. 24VFWR Max. 24VFWR Max.
at 10Ft. Per at 10Ft. Per Operating Operating Operating Operating
Horn Mode Operating Operating Operating Operating
ANSI/UL 464 ANSI/UL 464 Current Current Current Current
Current Current Current Current
(NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD)
(NORMAL) (LOUD) (NORMAL) (LOUD)

Temporal 3 520 Hz 77.8 dBA 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA

Temporal 4 520 Hz* 81.5 dBA 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA
*Temporal 4 520 Hz measured per ANSI/UL 2075

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0199 05/2015
HHLF - LOW FREQUENCY AUDIBLE SIGNAL

NOTES:
 This appliance is not recommended for use on coded or
pulsing signaling circuits
 The four pulse temporal pattern (temporal 4) can only be
obtained on this product when used in conjunction with the
Hochiki HTSM Synchronization Module

LOCKING
SCREW
(optional)

NORMAL-LOUD
DECIBEL JUMPER.
SLIDE ONTO BRACKET
FOR LOUD DECIBEL
INSTALL JUMPER.

LOCKING
Instant Voltage Verification: SCREW
It is often necessary to confirm the voltage drop along a line of devices. The access (optional)
holes are provided in the back of the terminal block to allow the voltage to be
measured directly without removing the device. Typically this would be done at the
end of the line to confirm design criteria. Most measurements will be taken using
the S+ and S- locations although access is provided to other locations.
NOTICE: CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES.

Mounting Bracket:
Allows the installer to pre-wire the system, test for system supervision, remove the
signal head until occupancy, switch out Hochiki America signals without changing
mounting brackets and has locking edge connector for snap-in-place installation.

ARCHITECT & ENGINEERING SPECIFICATIONS


The alarm horns shall be Hochiki model HHLF. The appliance shall be listed with Underwriters Laboratories (ANSI/
UL) for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S3597 with intended use in fire
alarm systems. The HHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The
appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a
mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double
gang box or double workbox without the use of an adapter plate. The HHLF shall be mounted on the wall or the ceil-
ing. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at
24 VDC. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without
removing unit and be capable of mounting to a surface back box.
NOTES:
 Operating temperature: 32° to 120°F (0° to 49°C). The HHLF is not listed for outdoor use.
 For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power,
see installation manual.
 The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.
 RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage
range (16-33VDC for 24VDC units).
 For unfiltered FWR ratings, see installation manual.

Hochiki America Corporation HHLF SERIES - LOW FREQUENCY AUDIBLE SIGNAL Specifications subject to change without notice.
B6-24 / B10-24 / BB-WP - FIRE ALARM BELL

SPECIFICATION
Model B6-24, B10-24
Operating Voltage 24VDC
Alarm Current 100mA
dB at 10ft. 96dB
Operating Temperature 32°F to 120° F
(Indoor Application) (0° C to 48° C)
Operating Temperature -32°F to 150° F
(Outdoor Application) (-35° C to 65° C)
Color / Material Red / Metal
Back box Dimension 4.25W” x 4.25”H x 1.5”D
B6-24/B10-24/BB-WP
STANDARD FEATURES
• UL Listed
APPLICATIONS • Available in 6" or 10" version
• High dbA output
The B6-24 and B10-24 provide durable and depend- • Mounts to a standard 4" square electrical box
able operation required for life safety alarm systems. • ANSI/UL Listed for outdoor use when used with the
Alarm bells are low current, high decibel notification BB-WP weatherproof back box
appliances for use in fire or other signaling applica- • 18 AWG wire leads
tions. The alarm bell is powered by 24VDC. • Meets ANSI/UL 464 requirements
Alarm bells are available in 6" or 10" version and listed • Red metal finish
for indoor and outdoor applications. Alarm bells must
be used with the BB-WP weatherproof box for outdoor
use.

WIRING DIAGRAM

PRODUCT LISTINGS
California State
Fire Marshal

• UL 464 - S1529
• CSFM Listed - 7135-0410:0209

Product Compliance
• NFPA 72

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0192 10/2014
MOUNTING

Hochiki America Corporation B6-24_B10-24_BB-WP


Specifications subject to change without notice.
Xtinguish

STANDARD FEATURES

• UL Listed for Class A, B, C fires


• Environmentally friendly (Green Label)
• Available in 10 models
• UL Listed for 10 years shelf life
• Easy installation, requires no piping or
pressurized bottles
• Minimal maintenance
• Requires far less real estate compared to a
typical Halon system
• Minimal cleanup on post fire
• Safe to handle
• Mounting brackets included for all models
• Compatible with HCVR-3 Fire Alarm Control
Panel

APPLICATIONS DESCRIPTION

• Data centers (server room) FNX Series products are a SBK aerosol forming solid
• Computer rooms compound (containing no pyrotechnic substances)
• Central stations (call centers) that is used to extinguish Class A, B, C fires. The FNX
• Mechanical / electrical control rooms Series products are electrically activated. The con-
• Shipping warehouse densed aerosol extinguishing mechanism works by
• Plant rooms removing the active chemical particles involved in the
• Engine rooms flame chain reaction.
• Vehicle storage rooms (hangar bay)

TRANSPORTATION CLASSIFICATION

• Class 9
• UN Identification: 3335 (Air) & 3077 (Ocean)
PRODUCT LISTINGS • Packaging group: PGIII

Shipping guidelines for maximum weight:


California
State Fire
• Ground: None
Marshal
• Ocean: None
EX16201 7080-0410:0205 • Cargo Air: 400 kg (881 lbs)
• Passenger Air: 30 kg (66 lbs)
BSI/A.1/3.46/62-133

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0169 03/2015
SPECIFICATIONS
C anister T yp e
M odel F N X -20S F N X -40S F N X -80S
M ass of S B K 20g 40g 80g
P roduct weight 310g ± 5% 610g ± 5% 870g ± 5%
S upply V oltage 6 ~ 36 V D C 6 ~ 36 V D C 6 ~ 36 VD C
Initiation C urrent 0.8 A 0.8 A 0.8 A
H eating E lem ent R esistance 1.6 – 3.6 O hm s 1.6 – 3.6 O hm s 1.6 – 3.6 O hm s
S upervision C urrent 5 mA 5 mA 5 mA
Ignition Tim e 4 seconds 4 seconds 4 seconds
D ischarge Tim e 3 – 6 seconds 5 – 10 seconds 5 – 10 seconds
M in. D ischarge Clearance 0.3ft (100 m m ) 0.3ft (100 m m ) 0.3ft (1 00m m )
(H um an)
M a x. M ounting Height 3.2ft (1m ) 3.2ft (1 m ) 6.5ft (2m )
S torage -58°F (-50°C ) - 122°F -58°F (-50°C ) - 122°F -58°F (-50°C) - 122°F
Tem perature (50°C ) (50°C ) (50°C )
S elf-A ctivation T em perature 572°F (300°C ) 572°F (300°C ) 572°F (300°C )
D im ensions 6.4”H (165 m m ) x 1.2”D 5.5”H (140 m m ) x 2.0”D 7.2”H (185 m m ) x 2.0”D
(32m m ) (51m m ) (51m m )

Canister Type
Model FNX-100S FNX-200S FNX-500S
Mass of SBK 100g 200g 500g
Product weight 1370g ±5% 1840g ±5% 3340g
Supply Voltage 6 ~ 36 VDC 6 ~ 36 VDC 6 ~ 36 VDC
Initiation Current 0.8 A 0.8 A 0.8 A
Heating Element Resistance 1.6 – 3.6 Ohms 1.6 – 3.6 Ohms 1.6 – 3.6 Ohms
Supervision Current 5mA 5 mA 5 mA
Ignition Tim e 4 seconds 4 seconds 4 seconds
Discharge Time 5 – 10 seconds 5 – 10 seconds 5 – 10 seconds
Min. Discharge Clearance 1.3ft (400mm) 0.9ft (300mm) 1.6ft (500mm)
Max. Mounting Height 3.2ft (1m ) 6.5ft (2m ) 6.5ft (2m )
Storage -58°F (-50°C) - 122°F (50°C) -58°F (-50°C) - 122°F (50°C) -58°F (-50°C) - 122°F (50°C)
Tem perature
Self-Activation Temperature 572°F (300°C) 572°F (300°C) 572°F (300°C)
Dimensions 6.1”H (155mm) x 3.4”D (84mm ) 7.2”H (185mm) x 3.4”D (84mm ) 11.6”H (295mm) x 3.4”D
(84mm )

B ox T yp e
Model FN X-1200 FN X-2000 FN X-3000 FN X-5700
Mass of SBK 1200g 2000g 3000g 5700g
Product weight 10900g ±5% 15500g ±5% 16300g ±5% 26400g ±5%
Supply Voltage 6 ~ 36 VD C 6 ~ 36 VD C 6 ~ 36 VD C 6 ~ 36 VDC
Initiation C urrent 0.8 A 0.8 A 0.8 A 0.8 A
H eating Elem ent 1.6 – 3.6 O hm s 1.6 – 3.6 O hm s 1.6 – 3.6 O hm s 1.6 – 3.6 Ohm s
R esistance
Supervision C urrent 5 mA 5 mA 5 mA 5 mA
Ignition Tim e 4 seconds 4 seconds 4 seconds 4 seconds
D ischarge Tim e 15 – 20 seconds 15 – 20 seconds 15 – 20 seconds 15 – 20 seconds
Min. D ischarge 5.4ft (1650m m ) 4.9ft (1500m m ) 6.5ft (2000m m ) 6.5ft (2000m m )
C learance
(H um an)
Ma x. Mounting H eight 11.4ft (3.5m ) 11.4ft (3.5m ) 11.4ft (3.5m ) 16.4ft (5m )
Storage -58°F (-50°C ) - 122°F -58°F (-50°C ) - 122°F -58°F (-50°C ) - 122°F -58°F (-50°C ) - 122°F
Tem perature (50°C ) (50°C) (50°C ) (50°C )
Self-Activation 572°F (300°C ) 572°F (300°C ) 572°F (300°C ) 572°F (300°C )
Tem perature
D im ensions 6.5”H (167m m ) x 7.2”H (185m m ) x 7.2”H (185m m ) x 11.8”H (300mm ) x
11.8”L (300m m ) x 11.8”L (300m m ) x 11.8”L (300m m ) x 11.8”L (300m m ) x
8.5”W (216m m ) 11.8”W (300m m ) 11.8”W (300m m ) 11.8”W (300m m )

Hochiki America Corporation FirePro Xtinguish Specifications subject to change without notice.
HCVR-3
CONVENTIONAL RELEASING FIRE ALARM CONTROL PANEL

STANDARD FEATURES

• UL 864 Listed and FM Approved


• Three detection zones
• Any single zone or any combination of zones can be
configured to release
• Fully programmable using simple menu options
• Simple, single board construction
DESCRIPTION • Installer friendly
• Compatible with wide range of detection devices
The HCVR-3 is a 3 zone conventional releasing fire alarm • Configurable first stage NAC delays
control panel that is UL Listed and FM Approved for releasing. • Configurable detection delays
• Built-in Manual Release switch and separate circuit
The HCVR-3 can be configured to activate releasing by a
• Compatible with FirePro® Xtinguish
single zone or combination of any two zones. The LCD display
• Compatible with various releasing valves
is used to show the countdown timer during activation of the
releasing sequence. • Configurable releasing delays up to 60 seconds in 5 second
intervals
The HCVR-3 is fully programmable using simple menu options. • Configurable releasing duration up to 5 minutes in 5 second
The panel is a single board construction which provides an intervals
easy replacement solution. It is also compatible with a wide • Releasing countdown timer displayed on the LCD
range of devices. • Supports up to seven HCVR-SDU or HCVR-AB
• Built-in relays for Fire, Trouble, Stage 1, Stage 2, Extract
and Local Fire

PRODUCT LISTINGS
SIGNALING
California State
Fire Marshal
7165-0410:0206
S6468 3046396
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com
F0154 04/2015
SPECIFICATIONS
Supply Voltage 115VAC (50hz/60hz) or 230VAC (50hz/60hz)
Power Supply DC Rating 24VDC 3 Amps total including battery charging
Mains Supply Fuse 1.6 Amps 250VAC, slow-blow, 5 x 20mm
Dimensions 15.2" (385mm)W x 12.2" (310mm)H x 3.5" (90mm)D
Weight 12.3 lbs.
Color Red or gray
Material 1.2mm mild steel
Max. Battery Size 7Ah 12V (2 per panel)
RS-485 Serial Bus Maximum line impedance 120 Ohms
Trouble Contact Rating 30VDC 1 Amp
Local Fire Contact Rating 30VDC 1 Amp
Fire Contact Rating 30VDC 1 Amp
1st Stage Contact Rating 30VDC 1 Amp
2nd Stage Contact Rating 30VDC 1 Amp
EXTING Contact Rating 30 VDC 1 Amp contacts for (NO) and (C)
EXTING Contact Rating 18 to 28VDC 1 Amp max load for 5 minutes and voltage reversing DC
NAC Output Rating 0.5 Amp per output
Detection Zone End of line resistor 6K8 Ohms 5% resistor
NAC Output 10K Ohms 5% resistor
Stand by Current 86 mA
Alarm Current 620 mA
Operating Humidity 93% (non condensing)
Operating Temperature -5°C to +40°C

HOCHIKI AMERICA COMPATIBLE DEVICES


MODEL DESCRIPTION MAX
PANEL ACCESSORIES
HCVR-SDU Remote Status Display Unit 7
HCVR-AB Ancillary Board 7
HCVR-SQA Sequential Activator 20
HCVR-DS Disconnect Switch 1
DETECTORS
SLR-24H Photoelectric Smoke Detector w/heat 20
SLR-835 Photoelectric 8-35V Smoke Detector 20
SLR-835/-835W Photoelectric 8-35V Smoke Detector 20
SLR-835-BH-2W Photoelectric 8-35V Smoke Detector w/heat 20
SLV-24V/-24/-24N Photoelectric Smoke Detector 20
SIJ-24 Ionization Smoke Detector 20
DCD-135 135° Fixed Temperature Rate of Rise Heat Detector 20
DCD-190 190° Fixed Temperature Rate of Rise Heat Detector 20
BASES
NS6-220 6" base, 43mA draw, 24V 20
NS4-220 4" base, 43mA draw, 24V 20
PULL STATION/ABORT SWITCH
HPS-SAK/HPS-DAH/HPS-SAH/HPS-DAK Conventional Manual Pull Station 1
HCVR-AS Abort Switch 1
RELEASING VALVES
HV2185328 ASCO Solenoid 1
8210G207 ASCO Solenoid 1
11601 Viking Solenoid 1
11602 Viking Solenoid 1
11592 Viking Solenoid 1
11591 Viking Solenoid 1
11596 Viking Solenoid 1
11595 Viking Solenoid 1
2823A-2NB-A4F6 Snap-tite Solenoid 1
EA45 (510006) Sevo Systems Solenoid 1
K-45-8017 Kidde Solenoid (equivalent to 486500-01) 1
B6793-859 Kidde Solenoid (equivalent to 81-100000-001) 1
753-E Series Victaulic Solenoid 1
305350 Ci IS8B Fire Eater Solenoid 1
305451 Ci IS8B Fire Eater Solenoid 1

Hochiki America Corporation CONVENTIONAL FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
HCVR-AB
Ancillary Board

SPECIFICATIONS
Supply Voltage 20 to 30 VDC
Dimensions 15.1”(W) x 12.2(H) x 3.54”(D)
Board Model HCVR-AB (Board only)
Enclosure Models HCVR-ABE-R, HVCR-ABE-C
(Enclosure only)
Color Red or Charcoal
Wiring Length 4000 ft. (RS485)
Standby Current 16 mA
Alarm Current 175 mA
Wiring Gauge 14 to 22 AWG
DESCRIPTION
Relay Contact 30VDC @ 1 Amp (Voltage
free change over contact)
The HCVR-AB is a Ancillary Board that provides volt Operating Humidity 95% RH (Non-Condensing)
free normally open contacts allowing control Operating Temperature 23°F to 122°F
remotely from the HCVR-3 FACP.

The Ancillary board requires data cable and 24VDC


STANDARD FEATURES
Aux power from the HCVR-3 Releasing FACP
• UL864 and FM Approved
Up to 7 HCVR-AB can be connected to a single • Compatible with HCVR-3 FACP
HCVR-3 Releasing FACP by using the binary coded • Four wire connection (data and power)
DIL switch for addressing. • Supervised data connection
• Available in Red or Charcoal enclosure (sold
separately)

PRODUCT LISTINGS

California
State Fire
Marshal 3046396
S6468 7300-0410:0207

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0157 09/2014
HCVR-SDU
STATUS DISPLAY UNIT

SPECIFICATIONS
Supply Voltage 21 to 28 VDC
Dimensions 7.3” (W) x 5.2 (H) x 1.9” (D)
Weight 9 lbs.
Color Red or Charcoal
Surface Mount Models HCVR-SDU-6S-R, HCVR-
SDU-6S-C, HCVR-SDU-6SM-
R, HCVR-SDU-6SM-C
Flush Mount Models HCVR-SDU-6F-R, HCVR-
SDU-6F-C, HCVR-SDU-6FM-
R, HCVR-SDU-6FM-C
Wiring Length 4000 ft. (RS485)
Standby Current 50 mA
DESCRIPTION Alarm Current 94 mA
Wiring Gauge 18 to 22 AWG
The HCVR-SDU is a status indicator that provides Operating Humidity 90% RH (Non-Condensing)
detailed status information for the HCVR-3 Releasing Operating Temperature 23°F (-5°C) to 122°F (50° C)
FACP.

The HCVR-SDU series provide LED indication of STANDARD FEATURES


manual only, automatic and manual, abort operated,
disabled, imminent and released conditions. Some
• UL864 and FM Approved
models provide zonal fire indicators and a common
trouble indicator. • Compatible with HCVR-3 FACP
• Remote Status Display of the HCVR-3 FACP
All HCVR-SDU contain a large LED display which • Four wire connection (data and power)
shows a countdown of the time remaining until • Supervised data connection
release in seconds. Also, all models have supervised • Displays countdown timer
inputs for remote connection of abort switches. • Internal buzzer and trouble diagnosis indicators
• Manual only and Automatic & Manual mode
select keyswitch option

PRODUCT LISTINGS

California
State Fire
Marshal 3046396
S6468 7300-0410:0207

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0156 09/2013
HCVR-AS
ABORT SWITCH

STANDARD FEATURES

• UL Listed and FM Approved


• Capable of aborting releasing operation
• Available in red or gray
• Includes a back box for surface mount

DESCRIPTION

HCVR-AS is a single action push button abort switch.


HCVR-AS is compatible with the HCVR-3 fire alarm control panel.
HCVR-AS is connected via terminal block connections.

SPECIFICATIONS
Models HCVR-AS-R (red)
HCVR-AS-G (gray)
Switch Rating 1A @ 30VDC
Dimension 3.81" W x 3.81" H x 2.32" D

PRODUCT LISTINGS
SIGNALING
California State
Fire Marshal
7300-0410:0207
S6468 3046396
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com
F0155 04/2015
HCVR-SQA - SEQUENTIAL ACTIVATOR

DESCRIPTION
The HCVR-SQA is a sequential activator that is used to
operate a fixed, condensed aerosol generator or canis-
ter for extinguishing fire in a confined space.

SPECIFICATIONS
STANDARD FEATURES Models HCVR-SQA
 UL Listed and FM Approved Supply Voltage 24VDC
®
 Used to activate up to two FirePro Xtinguish aerosol Average Current Consumption 1mA
generators Maximum Output Current 1A @ 24VDC
 Includes a back box for surface mount Material Mild steel
 Fault LED is illuminated to indicate trouble conditions Dimensions 3.58”W x 3.58”H x 1.61”D

COMPATIBILITY LIST
CANISTER TYPE BOX TYPE
HOCHIKI AMERICA
FNX-100S FNX-1200
FNX-200S FNX-2000
FNX-500S FNX-3000
FNX-5700
FIREPRO
FP-100S FP-1200
FP-200S FP-2000
FP-500S FP-3000
FP-5700

PRODUCT LISTINGS

California State
Fire Marshal
7300-0410:0207
S6468 3046396

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com F0167 09/2015
HCVR-SQA - SEQUENTIAL ACTIVATOR

WIRING DIAGRAMS

Connect jumper to last unit


Sequential Activator n in line
Connect as shown
when using one
generator

FNX-1200

Remove jumper on all units


Sequential Activator 2 except last in line

Connect as shown
when using two
generators FNX-3000

FNX-2000

Remove jumper on all units


Sequential Activator 1 except last in line

FNX-1200

FNX-5700

AUX 24V EXTING

HCVR-3 Fire Control Panel

Hochiki America Corporation HCVR-SQA Specifications subject to change without notice.


HPS-DAK-SR
Manual Pull Station for Fire Suppression Release

SPECIFICATIONS
Model HPS-DAK-SR
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)

STANDARD FEATURES

• Metal Construction
• Enclosed switch with glass rod (included)
• UL, CSFM Listed
• Made in USA

DESCRIPTION

HPS-DAK-SR is a dual action (lift & pull) fire suppres-


sion release manual pull station. HPS-DAK-SR model
ELECTRICAL WIRING is constructed of a solid die cast housing and comes
in glossy red. The back switch plate is plated steel.
The electrical switch is rated for 10 Amps @ 120 VAC
normally open contact rating. All models are con-
nected via terminal block connections.

PRODUCT LISTINGS

California
State Fire
Marshal

7150-0410:162
S6512

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0127 03/2012
HCVR-DS
DISCONNECT SWITCH

STANDARD FEATURES

• UL Listed and FM Approved


• Physical switch provides NFPA-compliant disconnect
solution for releasing service
• Includes a back box for surface mount

DESCRIPTION

HCVR-DS is a disconnect switch used to disable a releaing


circuit for system testing or maintenance.

HCVR-DS is compatible with the HCVR-3 Conventional


Releasing Fire Alarm Control Panel.

SPECIFICATIONS
Models HCVR-DS-R (red)
HCVR-DS-G (gray)
Switch Rating 1A @ 30VDC
Dimension 3.81" W x 3.81" H x 2.32" D

PRODUCT LISTINGS
SIGNALING
California State
Fire Marshal
7300-0410:0207
S5694 3046396
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800-845-6692 or technicalsupport@hochiki.com
F0197 04/2015
SOM-R-DS
Disable Switch

SPECIFICATIONS
Model SOM-R-DS
Switch Rating 4A @ 28VDC
Material Metallic
Dimension 2.31” W x 4.19” H x 1.5” D
Operating 32°F (0°C) ~ 120°F (49°C)
Temperature
Relative Humidity 90% RH Non-Condensing
Environment For Dry Indoor Use Only
Mounting Single gang electrical box

STANDARD FEATURES

SOM-R-DS • UL Listed and FM approved


• Physical switch provides NFPA-compliant
disable solution for releasing service

DESCRIPTION

SOM-R-DS is a double-pole single-throw disable


switch used to disable a releasing circuit for system
testing or maintenance. The SOM-R-DS is compatible
with SOM-R addressable module and the HCVR-3
Conventional Releasing Fire Alarm Control Panel.
SOM-R-DS is intended to be mounted to a single
gang electrical box.

PRODUCT LISTINGS

California
State Fire
Marshal 3042214
S5694 7300-0410:150

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0177 03/2013
TM
FireNET Vapor - VPR-1
DESCRIPTION
The FireNET VaporTM VPR-1 detector is an air-sampling
system with an alarm sensitivity range from 0.0003 - 6.10
%/ft obscuration (0.001 - 20 %/m). This detector is classified
as a Very Early Warning Smoke Detector and can reliably
detect fire at an early stage and low to high concentrations
of smoke over an area of 21,500 ft2 (2000 m2).

OPERATIONS
Programming and Configuration:

The four alarm sensitivity thresholds and delays can be


individually programmed. The VPR-1 detector provides a
simple and comprehensive display that includes an LED
array to show the measured smoke level and an on-board
programmer for local configuration.
STANDARD FEATURES RS232, RS485 and TCP/IP communication interfaces are
available to connect to the Hochiki Configuration software
• Single Zone package: FireNET VaporTM Explorer. RS485 interfaces also
• Four Pipe Air Sampling allow connections to programming devices and remote
• 0.0003 - 6.10 %/ft obscuration displays and the TCP/IP Ethernet interface can provide
(0.001 - 20 %/m) access to an email messaging service.
• 4 Alarm Levels - Alert, Action, Fire 1, Fire 2
• 4 x 328ft (4 x 100m) sampling pipes Inputs and Outputs:
• Enhanced performance aspirator
The VPR-1 detector supports a number of optional
• Ethernet TCP/IP modules, which provide the detector with additional
• Modbus interface for programming programmable output relay interfaces and 4 to 20 mA
• 5 relay outputs analog output.
• Optional 4 to 20mA analog outputs and relay cards
• Area coverage of up to 21,500 ft2 (2000 m2) Aspirating and Flow Sensing:

APPLICATIONS The aspirator is a 2000 Pa high pressure and high volume


fan, which provides superior detection times over long pipe
lengths and reliable detection in high air flow environments.
The FireNET VaporTM VPR-1 detector is configurable for a
Airflow in each pipe is monitored by a dual element thermal
variety of environments, providing an ideal fire detection
sensing system, with airflow faults indicated on the display
solution for power stations, telecommunications and IT
and reported to monitoring equipment.
facilities, clean rooms, warehouses, cold storage, harsh
and hazardous areas, historic buildings and museums.
ORDERING INFORMAION
VPR-1 - Aspirating Smoke Detector
PRODUCT LISTINGS (0200-06050)
VPR-RM4 - 4 Channel Relay Module
California (0400-03200)
State Fire VPR-CLO8 - 8 Channel Analog Output Module
Marshal
(0400-03210)
7259:0410:0202
VPR-1-RD - Remote Display Module
S3516
(0500-06630)
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0173 07/2013
SPECIFICATIONS

Supply Voltage 24 VDC


Supply Current 500mA (min) – 1.2A (max)
Aspirator 2000 Pa Centrifugal air pump
Dimensions 19.3”W (490mm) x 14.0”H (355mm) x 7.9”D (200mm)
Operating Temperature 32 - 100°F (0 - 38°C)
Maximum Humidity 10 – 95% RH (non-condensing)
Sampling Network Zones: 1 Fire detection zone
Pipe Length: 4 x 328ft (4 x 100m)
Alarm Sensitivity Range 0.0003 – 6.10 %/ft
(0.001 – 20 %/m)
Alarm Settings Alarm levels: Alert, Action, Fire 1 and Fire 2
Alarm delays: 0 – 60 seconds
IP Rating IP30
Filtration Field exchangeable dual stage filter
Flow Monitoring Twin thermal element per input pipe
Relay Outputs 4 alarm relays, 1 fault relay, 1 Amp changeover Rating
1A @ 30VDC, NO/NC
Communication RS232, RS485 Modbus and Ethernet TCP/IP
Event Log Up to 20,000 events stored

DIMENSIONS

Hochiki America Corporation FireNET Vapor - VPR-1 Specifications subject to change without notice.
TM
FireNET Vapor - VPR-1P

DESCRIPTION
The FireNET VaporTM VPR-1P detector is an air-sampling
system with an alarm sensitivity range from 0.0003 - 6.10
%/ft obscuration (0.001 - 20 %/m). This detector is classified
as a Very Early Warning Smoke Detector and can reliably
detect fire at an early stage and low to high concentrations
of smoke over an area of 9,150 ft2 (850 m2).

OPERATIONS
Programming and Configuration:

RS232, RS485 and TCP/IP communication interfaces are


available to connect to the Hochiki Configuration software
package: FireNET VaporTM Explorer. RS485 interfaces also
allow connections to programming devices and remote
STANDARD FEATURES displays and the TCP/IP Ethernet interface can provide
access to an email messaging service.
• Single Zone
• Dual Pipe Air Sampling Aspirating and Flow Sensing:
• 0.0003 - 6.10 %/ft obscuration
(0.001 - 20 %/m) The aspirator is a 2000 Pa high pressure and high volume
• 4 Alarm Levels - Alert, Action, Fire 1, Fire 2 fan, which provides superior detection times over long pipe
lengths and reliable detection in high air flow environments.
• 2 x 328ft (2 x 100m) sampling pipes
Airflow in each pipe is monitored by a dual element thermal
• Enhanced performance aspirator sensing system, with airflow faults indicated on the display
• Ethernet TCP/IP and reported to monitoring equipment.
• RS232 and RS485 Modbus interface for programming
• 5 relay outputs
• Area coverage of up to 9,150 ft2 (850 m2)
ORDERING INFORMAION

APPLICATIONS VPR-1P - Aspirating Smoke Detector


(0200-06040)
The FireNET VaporTM VPR-1P detector is configurable for a
variety of environments, providing an ideal fire detection
solution for power stations, telecommunications and IT
facilities, clean rooms, warehouses, cold storage, harsh
and hazardous areas, historic buildings and museums.

PRODUCT LISTINGS

California
State Fire
Marshal
7259:0410:0202
S3516

Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0172 12/2014
SPECIFICATIONS

Supply Voltage 24 VDC


Supply Current 500mA (min) – 1.2A (max)
Aspirator 2000 Pa Centrifugal air pump
Dimensions 10.0”W (254mm) x 7.1”H (180mm) x 6.5”D (165mm)
Operating Temperature 32 - 100°F (0 - 38°C)
Maximum Humidity 10 – 95% RH (non-condensing)
Sampling Network Zones: 1 Fire detection zone
Pipe Length: 2 x 328ft (2 x 100m)
Alarm Sensitivity Range 0.0003 – 6.10 %/ft
(0.001 – 20 %/m)
Alarm Settings Alarm levels: Alert, Action, Fire 1 and Fire 2
Alarm delays: 0 – 60 seconds
IP Rating IP65
Filtration Field exchangeable dual stage filter
Flow Monitoring Twin thermal element
Relay Outputs 4 alarm relays, 1 fault relay, 1 Amp changeover Rating
1A @ 30VDC, NO/NC
Communication RS232, RS485 Modbus and Ethernet TCP/IP
Event Log Up to 20,000 events stored

DIMENSIONS

Hochiki America Corporation FireNET Vapor - VPR-1P Specifications subject to change without notice.
TM
FireNET Vapor - VPR-4 & VPR-6
DESCRIPTION
The FireNET VaporTM VPR-4 & VPR-6 detectors are multi-
channel air-sampling system with an alarm sensitivity range
from 0.0003 - 6.10 %/ft obscuration (0.001 - 20 %/m). These
detectors are classified as Very Early Warning Smoke
Detectors and can reliably detect fire at an early stage and
low to high concentrations of smoke over an area of 21,500
ft2 (2000 m2). As a multi-channel system, the VPR detector
is able to divide a protected space into sampling sectors,
enabling the localization of a fire for faster incident response.

OPERATIONS
Programming and Configuration:

The four alarm sensitivity thresholds and delays can be


individually programmed. The VPR detector provides a
simple and comprehensive display that includes an LED
STANDARD FEATURES array to show the measured smoke level and an on-board
programmer for local configuration.
• 4 or 6 pipe addressable air sampling
RS232, RS485 and TCP/IP communication interfaces are
• 0.0003 - 6.10 %/ft obscuration
available to connect to the Hochiki Configuration software
(0.001 - 20 %/m) package: FireNET VaporTM Explorer. RS485 interfaces also
• 4 Alarm Levels - Alert, Action, Fire 1, Fire 2 allow connections to programming devices and remote
• 4 x 328ft (4 x 100m) or displays and the TCP/IP Ethernet interface can provide
6 x 326ft (6 x 100m) sampling pipes access to an email messaging service.
• Enhanced performance aspirator
• Ethernet TCP/IP Inputs and Outputs:
• Modbus over RS232 and RS485
• 5 relay outputs and expandable The VPR detector supports a number of optional modules,
which provide the detector with additional programmable
• Optional 4 to 20mA analog outputs and relay cards
output relay interfaces and 4 to 20 mA analog outputs.
• Area coverage of up to 21,500 ft2 (2000 m2)
Aspirating and Flow Sensing:
APPLICATIONS
The aspirator is a 2000 Pa high pressure and high volume
The FireNET Vapor VPR-4 & VPR-6 detectors are
TM fan, which provides superior detection times over long pipe
configurable for a variety of environments, providing an lengths and reliable detection in high air flow environments.
ideal fire detection solution for power stations, Airflow in each pipe is monitored by a dual element thermal
telecommunications and IT facilities, clean rooms, sensing system, with airflow faults indicated on the display
warehouses, cold storage, harsh and hazardous areas, and reported to monitoring equipment.
historic buildings and museums.
ORDERING INFORMAION
VPR-4 & VPR-6 - Aspirating Smoke Detector
PRODUCT LISTINGS (0200-06060 & 0200-06070)
VPR-RM4 - 4 Channel Relay Module
California (0400-03200)
State Fire VPR-CLO8 - 8 Channel Analog Output Module
Marshal
(0400-03210)
7259:0410:0202
S3516 VPR-4-RD & VPR-6-RD - Remote Display Module
(0500-06640 & 0500-06650)
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0174 07/2013
SPECIFICATIONS

Supply Voltage 24 VDC


Supply Current 500mA (min) – 1.2A (max)
Aspirator 2000 Pa Centrifugal air pump
Dimensions 19.3”W (490mm) x 14.0”H (355mm) x 7.9”D (200mm)
Operating Temperature 32 - 100°F (0 - 38°C)
Maximum Humidity 10 – 95% RH (non-condensing)
Sampling Network Sectors:
4 Fire sectors (VPR-4)
6 Fire sectors (VPR-6)
Pipe Length:
4 x 328ft (4 x 100m) for VPR-4
6 x 328ft (6 x 100m) for VPR-6
Alarm Sensitivity Range 0.0003 – 6.10 %/ft
(0.001 – 20 %/m)
Alarm Settings Alarm levels: Alert, Action, Fire 1 and Fire 2
Alarm delays: 0 – 60 seconds
IP Rating IP30
Filtration Field exchangeable dual stage filter
Flow Monitoring Twin thermal element per input pipe
Relay Outputs 4 alarm relays, 1 fault relay, 1 Amp changeover Rating
1A @ 30VDC, NO/NC
Communication RS232, RS485 Modbus and Ethernet TCP/IP
Event Log Up to 20,000 events stored

DIMENSIONS

Hochiki America Corporation FireNET Vapor - VPR-4 & VPR-6 Specifications subject to change without notice.
FireNET VaporTM - VPR-15
DESCRIPTION
The FireNET VaporTM VPR-15 detector is an air-sampling
system with an alarm sensitivity range from 0.0003 - 6.10
%/ft obscuration (0.001 - 20 %/m). This detector is classified
as a Very Early Warning Smoke Detector and can reliably
detect fire at an early stage and low to high concentrations
of smoke over an area of 16,150 ft2 (1500 m2).

OPERATIONS
Programming and Configuration:

The four alarm sensitivity thresholds and delays can be


individually programmed. The VPR-15 detector provides a
simple and comprehensive display that includes an LED
array to show the measured smoke level for the currently
selected microbore and an on-board programmer for local
configuration.
STANDARD FEATURES
RS232, RS485 and TCP/IP communication interfaces are
• 15 Tube Addressable Air Sampling available to connect to the Hochiki Configuration software
• 0.0003 - 6.10 %/ft obscuration package: FireNET VaporTM Explorer. RS485 interfaces also
(0.001 - 20 %/m) allow connections to programming devices and remote
• 4 Alarm Levels - Alert, Action, Fire 1, Fire 2 displays and the TCP/IP Ethernet interface can provide
• 15 x 164ft (15 x 50m) microbore sampling tubes access to an email messaging service.
• Reliable linear pump technology
• Ethernet TCP/IP Inputs and Outputs:
• Modbus interface for programming
The VPR-15 detector supports a number of optional
• 5 relay outputs modules, which provide the detector with additional
• Optional 4 to 20mA analog outputs and relay cards programmable output relay interfaces and 4 to 20 mA
• Area coverage of up to 16,150 ft2 (1500 m2) analog outputs.

Aspirating and Flow Sensing:


APPLICATIONS
The aspirator is a linear vacuum pump, which provides
The FireNET VaporTM VPR-15 detector is configurable for a superior detection times over long tube lengths and reliable
variety of environments, providing an ideal fire detection detection in high air flow environments. Airflow in each tube
solution for cabinets, server rooms, prisons, historic is monitored by a differential pressure sensor, with airflow
buildings, art galleries and museums. faults indicated on the display and reported to monitoring
equipment.

ORDERING INFORMAION
VPR-15 - Aspirating Smoke Detector
PRODUCT LISTINGS (0200-06080)
VPR-RM4 - 4 Channel Relay Module
California
(0400-03200)
State Fire
VPR-CLO8 - 8 Channel Analog Output Module
Marshal
7259:0410:0202 (0400-03210)
S3516 VPR-15-RD - Remote Display Module
(0500-06660)
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0175 07/2013
SPECIFICATIONS

Supply Voltage 24 VDC


Supply Current 1.30mA (Quiescent) – 1.33A (Scanning)
Aspirator Linear vacuum pump
Dimensions 19.3”W (490mm) x 14.0”H (355mm) x 7.9”D (200mm)
Operating Temperature 32 - 100°F (0 - 38°C)
Maximum Humidity 10 – 95% RH (non-condensing)
Microbore Tube Diameter Outer tube: 0.24” (6mm)
Inner tube: 0.16” (4mm)
Microbore Tube Length 15 x 164ft (15 x 50m)
Alarm Sensitivity Range 0.0003 – 6.10 %/ft
(0.001 – 20 %/m)
Alarm Settings Alarm levels: Alert, Action, Fire 1 and Fire 2
Alarm delays: 0 – 60 seconds
IP Rating IP30
Filtration Field exchangeable dual stage filter
Flow Monitoring Differential pressure sensor
Relay Outputs 4 alarm relays, 1 fault relay, 1 Amp changeover Rating
1A @ 30VDC, NO/NC
Communication RS232, RS485 Modbus and Ethernet TCP/IP
Event Log Up to 20,000 events stored

DIMENSIONS

Hochiki America Corporation FireNET Vapor - VPR-15 Specifications subject to change without notice.
TM
FireNET Vapor - VPR-SD1 & VPR-SD2

DESCRIPTION
The FireNET VaporTM VPR-SD1 & VPR-SD2 are aspirating
smoke detection systems that utilize an air-sampling pipe
network to draw air towards analog addressable point
detectors (ALK-V) installed inside a sealed enclosure. The
VPR-SD1 has one pipe inlet and provision for one or two
point detectors allowing redundant or double-knock
detection. The VPR-SD2 has two pipe inlets and provision
for two separate point detectors, each monitoring a separate
sampling pipe run, which allows for redundant or double-
knock detection.

DETECTOR CONFIGURATION OPTIONS


Detector Configuration Options:

Configuration options are available for the VPR-SD1 and


STANDARD FEATURES VPR-SD2 systems:

• Listed to UL268 & UL268A • VPR-SD1 system - one or two spot (point) detectors
• Single or dual inlet fire detection (shared inlet)
• Multiple Piping options • VPR-SD2 system - two spot (point) detectors
• Multiple detection strategies (dual inlet)
• Pipe Length(s) up to164ft (50m) total per device
• Flexible Tube Length(s) up to 50ft (15m) maximum VPR-SD1 systems with one spot (point) detector are
• Microprocessor controlled capable of providing single area detection, but VPR-SD1
• High performance aspirator and VPR-SD2 systems with two detectors are able to
• Integral display and programmer provide a number of detection strategies. The table
• Field serviceable air filter below describes the recommended configuration
• Adjustable aspirator speed with airflow monitoring options for the selected detection strategy when two spot
• Compatible with FireNET and FireNET Plus FACP (point) detectors are installed into a VPR-SD system.

APPLICATIONS
The FireNET VaporTM VPR-SD1 & VPR-SD2 detectors are
configurable for a variety of environments, providing an
ideal fire detection solution for correctional facilities,
transformer vaults, cable tunnels, elevator machine rooms
and HVAC ducts.
*Subject to local codes and standards

PRODUCT LISTINGS ORDERING INFORMATION


California VPR-SD1: (0200-06090)
State Fire VPR-SD2: (0200-06100)
Marshal
Pending *ALK-V detector and fitting accessories are sold seperately.
S3516

Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0171 11/2012
SPECIFICATIONS

Supply Voltage 24 VDC


Supply Current 350mA (min) – 680mA (In-rush)
Aspirator 2000 Pa Centrifugal air pump
Dimensions 10.2”W (259mm) x 12.6”H (321mm) x 6.5”D (166mm)
Operating Temperature 32 - 100°F (0 - 38°C)
Maximum Humidity 10 – 95% RH (non-condensing)
Air Inlet Pipe Metric: 25mm (1.05”)
American Pipe: ¾” I.D (21mm)
Flexible tubing: ¾” O.D (19mm)
Alarm Sensitivity Range 1.00 – 2.06 %/ft
Sampling Network Pipe Length: Up to 164ft (50m) total per device
Flexible tubing: Up to 50ft (15m)
IP Rating IP30 Wiring Enclosure
IP65 Detector Enclosure
Filtration Serviceable filter
Flow Monitoring High and low programmable flow limits
Aspirator Control: 10 programmable speeds
Pressure: 250 Pa
Relay outputs VPR-SD1 – 1 fault relay output
VPR-SD2 – 2 fault relay outputs
Field Wiring 18 to 10 AWG solid
20 to 12 AWG stranded

DIMENSIONS

Hochiki America Corporation FireNET Vapor - VPR-SD1 & VPR-SD2 Specifications subject to change without notice.
TM
FireNET Vapor - Accessories

SPECIFICATION
Remote Display Units
Supply Voltage 24 VDC
Communication RS485
4 Channel Relay Module
Relay Rating 2A, Form C Relay
8 Channel 4 to 20 mA Output Module
Output Rating 4 to 20 mA
Resolution 16 bit

DESCRIPTION
The FireNET Vapor TM accessories provide added
STANDARD FEATURES functionality for the FireNET Vapor series (VPR-1, VPR-4,
VPR-6 & VPR-15 only) of detectors. With the addition of
Remote Display Units remote display units and plug-in modules, extra functionality
• Remote monitoring, control and status annunciation such as remote monitoring and control, status annunciation,
4 Channel Relay Module extra relay contact outputs and analog outputs can be
integrated in one central device.
• Extra relay contact outputs
8 Channel 4 to 20 mA Output Module
• Multiple analog current outputs for retransmission of OPERATIONS
signals
Remote Display Units:

ORDERING INFORMATION The remote display units (VPR-1-RD, VPR-4-RD, VPR-6-


RD & VPR-15-RD) allows a detector to be monitored,
VPR-1-RD - Remote Display Unit for VPR-1 only
controlled and programmed remotely. RS485
(0500-06630) communication is used between the detector and the
VPR-4-RD - Remote Display Unit for VPR-4 only remote display unit for monitoring and control.
(0500-06640)
Relay and Analog Output Modules:
VPR-6-RD - Remote Display UNit for VPR-6 only
(0500-06650) The relay and analog output modules plug onto the I/O
VPR-15-RD - Remote Display Unit for VPR-15 only module slots in a stackable chain up to 5 for VPR-1 to VPR-
(0500-06660) 15 series detectors.
VPR-RM4 - 4 Channel Relay Module The main use of relays is to provide individual sector alarms
(0400-03200) (i.e. fully addressable) on scanning systems VPR-4, VPR-
VPR-CLO8 - 8 Channel Current Output Module 6 and VPR-15. Each set of four relays may be configured
(0400-03210) for ALERT, ACTION, FIRE 1, FIRE 2, Flow Fault or General
Fault.
PRODUCT LISTINGS The 8-channel 4 to 20 mA output module is typically used
for retransmission of flow or smoke levels from the VPR
California detector. The maximum voltage output is 20 volts, the
State Fire resolution is 16 bits.
Marshal
Pending
S3516

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0179 07/2013
Design and Engineering Services

Expert Design and Technical Support for Your FireNET Vapor System
Who better to design and provide technical support for FireNET Vapor than the company that manufactures FireNET Vapor
aspirating smoke detection (ASD)? Our Application Engineers are ready to provide efficient and cost-effective design support for all of
your FireNET Vapor projects.

Design Services

Fees for FireNET


T Vapor de
esign per detector: Fire
eNET Vaporr de
esig
gn feess incclu
ude:
VPR-15 $400 1st / $250 each additional Project specification review
VPR-6 $400 1st / $250 each additional FireNET Vapor pipe layout in CAD†
VPR-4 $400 1st / $250 each additional FireNET Vapor Designer flow calculations†
VPR-1 $150 1st / $100 each additional Bill of materials†
VPR-1P $150 1st / $100 each additional Changes following formal design review††

indicates line item can be used for submittals.
††
as long as design review occurs within one week after design is delivered.

Change orders and as-builts: $150 per hour.

Call ou
ur Tecchnical Servvice
es Departmen
nt at 1-8
800-84
45-6692
www.hochiki.com
OSID - Smoke Imaging Detection
DESCRIPTION
The OSID (Open-area Smoke Imaging Detection) by Xtralis
is a new innovation in projected beam smoke detection
technology. By using advanced dual wavelength projected
beams and optical imaging technology, OSID provides a
low-cost, reliable and easy to install solution that overcomes
typical beam detection issues such as false alarm incidents
and alignment difficulties.

OPERATIONS
Status information (Fire Alarm, Trouble and Power) is
communicated through the imager via Status LEDs,
dedicated Trouble and Alarm relays, and the remote
indicator interface. Specific Trouble (Fault) conditions are
identified through coded flashes of the Trouble LED.

An internal heating option is also provided on the Imager to


STANDARD FEATURES prevent condensation on the optical surface, and a reset
• Maximum detection range of 492 ft. (150 meters) for the input enables an external signal to reset the device.
OSI-10
• Status LEDs for Fire, Trouble and Power The OSID system measures the level of smoke entering
• High false alarm immunity beams of light projected over an area of protection. A single
OSID Imager can detect up to seven emitters to provide a
• Dust and intrusive solid object rejection
wide coverage area. Two innovations in smoke detection
• Easy alignment with large adjustment and viewing angles technology have been developed for the revolutionary OSID
• No need for precise alignment smoke detector:
• Tolerant of alignment drift
• Automatic commissioning in under ten minutes Dual Wavelength Particle Detection
• Simple DIP switch configuration The beam projected from each Emitter contains a unique
• Dual wavelength LED-based smoke detection sequence of ultraviolet (UV) and infrared (IR) pulses that
• Simple and easy maintenance requirements are synchronized with the Imager and enable the
• Conventional alarm interface for straightforward fire system rejection of any unwanted light sources.
integration By using two wavelengths of light to detect particles, the
• Three selectable alarm thresholds system is able to distinguish between particle sizes. The
shorter UV wavelength interacts strongly with both small
PRODUCT LISTINGS and large particles while the longer IR wavelength is
• UL / ULC affected only by larger particles. Dual wavelength path
• AFNOR loss measurements therefore enable the detector to
• CE - EMC and CPD provide repeatable smoke obscuration measurements,
while rejecting the presence of dust particles or solid
• VdS
intruding objects.
• ActivFire
• CSFM Approved Optical Imaging with CMOS Imaging Chip
ORDERING INFORMATION An optical imaging array in the OSID Imager provides the
detector with a wide viewing angle to locate and track
OSI-10 - Imager: 7 coverage multiple Emitters. Consequently, the system can tolerate
OSI-45 - Imager: 38 coverage a much less precise installation and can compensate for
OSI-90 - Imager: 80 coverage the drift caused by natural shifts in building structures.
OSE-SP - Emitter: Standard Power Optical filtering, high-speed image acquisition and
intelligent software algorithms also enable the OSID
OSE-SPW - Emitter: Standard Power, Wired
system to provide new levels of stability and sensitivity
OSE-HPW - Emitter - High Power, Wired with greater immunity to high level lighting variability.
OSID-INST - OSID Installation Kit
OSP-001 - FTDI Cable 1.5m
OSP-002 - Laser Alignment Tool Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0180 05/2014
SPECIFICATIONS
Supply Voltage 24 to 30 VDC (24 VDC Nominal)
Supply Current Nominal: 8 mA (1 Emitter) – 10 mA (7 Emitters)
Imager Peak: during training mode: 31 mA
Supply Current Nominal: 350 uA (Std Power) 800 uA High Power
Emitter Battery Version: Built-in 5 Year Battery
Dimensions 7.8”W (198mm) x 5.1”H (130mm) x 3.7”D (96mm)
Operating Temperature 14 - 131°F (-10 - 55°C)
Maximum Humidity 10 – 95% RH (non-condensing)
Alarm Threshold Levels Low – Highest sensitivity/earliest alarm: 20% (0.97 dB)
Medium – Medium sensitivity: 35% (1.87 dB)
High – Lowest sensitivity / maximum immunity to
nuisance smoke conditions: 50% (3.01 dB)
Adjustment Angle 60°(horizontal), 15°(vertical)
Maximum Misalignment 2°
Angle
Alarm Settings Alarm levels: Alert, Action, Fire 1 and Fire 2
Alarm delays: 0 – 60 seconds
IP Rating IP44 for Electronics
IP66 for Optics Enclosure
Status LEDs Fire Alarm (Red)
Trouble/Power (Bi-color Yellow/Green)

CONFIGURATION OPTIONS

DIMENSIONS

Hochiki America Corporation OSID Specifications subject to change without notice.


FireNET™Marine - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
STANDARD FEATURES
• Analog design using Hochiki’s advanced DCP
protocol for fast communication
• Up to 127 sensors & modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop
• Uses standard wire, no-shielded or twisted pair required
on SLC loops
• Programmable sensitivity levels by device
• Alarm Verification feature
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• RS-485 bus for panel network (option)
• Built-in RS-232 interface for programming via a PC
• 3 on board programmable Form C relays rated at 1 amp
DESCRIPTION at 30VDC
• 2 auxiliary power outputs, each rated 360mA at 24 VDC
The FireNET™ Marine (FNM-2127) series control • Loop Explorer Windows® configuration utility
panel is an analog addressable fire alarm panel with • Auto-learn feature
build options containing 1 or 2 SLC loops, a Digital
Alarm Communicator/ Transmitter (DACT), and an
• 500 network wide software zones
RS-485 bus for network communication. Each SLC • Network Capability of up to 64 panels (option)
loop supports 127 devices of any combination • Built in help and alarm information screens
(sensors or modules), and 127 analog sounder bases, • 2 on-board Class B (style Y) NAC circuits rated at 2.3
for a possible total of 254 points per loop. amps each (Special Application) and 1.6 amps each
Communication between devices is accomplished by (Regulated continuous)
use of standard cable (shielded or twisted pair is not • Gentex, System Sensor, Wheelock, and Amseco NAC
required). Each panel includes a 4-amp power supply sync protocol built-in
and has 2 on-board NAC circuits. The RS-485 bus • Automatic day/night sensitivity modes
provides communication to the panel network while • Fire Drill test function
another RS-485 bus provides communication for • Walk Test function
peripheral devices. The RS-232 interface allows the • Powerful & versatile Cause & Effect wizard including:
convenience of programming via a PC. The system
*Cause & Effect action
will support a variety of Hochiki devices; photo and
*Disable function configuration
Multi-criteria sensors, which contain a unique,
*Test mode configuration
patented sensor design incorporating automatic drift
compensation and day/night sensitivity modes.
Additional devices include contact monitors, relay
controllers and manual pull. The Loop Explorer
Windows® Software interface provides the installer
with fingertip access to installation programming and
diagnostic tools. An Auto Learn feature offers the
convenience for quick start applications. Add to this a PRODUCT LISTINGS
reputation for high quality and dedicated service which
makes this an exceptional product both in
performance and value.
161.002/A58/0
S6468

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0142 05/2013
SPECIFICATIONS
Primary AC 120VAC @ 2.1 Amps 50/60hz or 220VAC @ 1.1Amps 50/60hz
Output DC 24VDC @ 5.25 Amps
Power Supply 4 Amp integrated
Charger Current 1.5 Amps max.
Dimensions 14.5" W x 19" H x 3.5" D
Weight 20 lbs. (without batteries)
Color Red (optional charcoal)
Material ABS/steel enclosure
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 panels max.)
Zones 500 network wide software zones per system
SLC loops 1 or 2 (class A, "style 6 or 7" or class B, "style 4")
Devices per loop 127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel 800 addresses+sub-addresses max. per panel
NAC Outputs (2) class B, 2.3 Amps (special application)
1.6 Amps Regulated (continuous)
Relay Outputs (3) Form C 1 Amp @ 30VDC
Aux. Power 2 outputs, 360mA @ 24VDC each
PC Port / Printer RS232

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES


MODEL DESCRIPTION
ANNUNCIATOR
FNM-LCD-S Serial LCD Annunciator

SLC LOOP DEVICES


FNM-ALK-V Analog Addressable Photoelectric Sensor
FNM-ACA-V Analog Addressable Multi-criteria Sensor (Photo & Heat)
FNM-NSA-6 Six inch Sensor Base
FNM-NSA-4 Four inch Sensor Base
FNM-FRCME-M Contact Monitoring Module (mini w/terminal blocks)
FNM-FRCMA Class A Contact Monitoring Module
FNM-DIMM Dual Input Monitor Module
FNM-R2ML Dual Relay Module
FNM-AMS-KL-LP Addressable Manual Pull Station
ACCESSORIES
TCH-B100 Hand Held Programmer (portable device addresser)

Hochiki America Corporation FireNET Marine ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FNM-LCD-S - SERIAL LCD ANNUNCIATOR
STANDARD FEATURES

• UL 864 9th edition Listed


• Large 320 character liquid crystal display (8 line
x 40 character) allows viewing of system status
• LED indicators for Fire, Supervisory Alarm, Pre-
Alarm, Fire Output Active, AC Power On, On
Test, Panel Sounder Silenced, Delay Active,
More Events, Point Bypassed, General Trouble,
Power Trouble, System Trouble & NAC Trouble
• Same controls as the FireNET fire panel (Reset,
DESCRIPTION Panel Sounder Silence, Lamp Test, Alarm
Silence, Re-sound Alarm, Fire Drill, Program-
mable Function, More Events, More Fire Events,
The FNM-LCD-S serial annunciator provides a Enter & Exit)
convenient and cost effective remote annunciator • Up to 15 FN-LCD-S serial annunicators may be
solution. Up to 15 FNM-LCD-S annunciators can be connected to a FireNET control panel or network
connected to the slave RS-485 port of the FireNET annunciator
control panel or network annunciator. The FNM-LCD- • Resides on the FireNET slave RS-485 line
S’s large 320 character display and navigation buttons
• Local piezo sounder for event notification
are a complete mimic of the FireNET control panel
display. The use of a common interface allows the • Supports user codes & firefighter key to enable
access & controls
user to easily operate the FNM-LCD-S as if he were
operating the FireNET control panel directly. • Powered by FireNET Aux 24VDC or UL fire listed
Aux. 24VDC supply
Security is established by the use of a password or • Available in red or charcoal, and can be surface
firefighters enable key. Designed to be aesthetically or flush mounted
pleasing, the FNM-LCD-S is available in charcoal grey • Built-in help & alarm information screens
or red enclosures. The FNM-LCD-S can be surface or • Fire drill function
flush mounted without the need for a trim ring.
SPECIFICATIONS
Current Draw
Standby: 20mA @ 24VDC
Alarm: 110mA @ 24VDC
Dimensions
FN-LCD-S 10.88" W x 8.00" H x 1.38" D
Back Box 10.38" W x 7.38" H x 1.25" D
Weight 3.5 lbs
Color Red (optional charcoal)
PRODUCT LISTINGS
Material ABS/steel enclosure
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condsensing
161.002/A58/0 Display 8 line x 40 character LCD
S6468 (320 characters total)
Specifications subject to change without notice. Network RS485 port
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0181 05/2013
ENGINEERING SPECIFICATION

The contractor shall furnish and install where indicated on the plans, the serial remote annunciator model
FNM-LCD-S. The FNM-LCD-S shall connect to the FireNET fire alarm control panel (FACP) or network
annunciator (FNM-LCD-N) RS485 slave bus. The serial remote annunciator shall annunciate on its 320
character display and local buzzer, the condition of its master FireNET FACP. Up to 15 FNM-LCD-S
serial annunciators may be connected together on a single RS-485 FireNET slave bus. The FNM-LCD-S
shall be UL listed and compatible with the Hochiki FireNET control panel, and have surface or flush mount
capability.

WIRING DIAGRAM

1522RO @

FIT JUMPER
ADDRESS COMM1 0V +24V COMM2 FOR END OF LINE
RESET W/ DOG RESET COMM2 COMM1
+

+
l

ON K S

1 2 3 4 COMMS
ACTIVE

Reset
Not Used
Switch
Not Used

DIP Switch used to set


the FNM-LCD-S address
between 1 -15 RS485 End-of-line jumper. Put
jumper in place when FNM-LCD-
S is the last device on the RS485
buss “I/O Comm”.

To next
(+)
serial
+ - (-)
24 VDC
FNM-
LCD-S
COMMS (+)
or other
RS-485 RS485
Buss
(-)
FireNET Control Panel Device
Comms Bus

To AUX 24VDC of control


panel or to UL 864/1481 listed
AUX 24VDC Power Supply

Hochiki America Corporation FNM-LCD-S Specifications subject to change without notice.


FNM-ALK-V PHOTOELECTRIC SMOKE SENSOR
APPLICATION
The HOCHIKI America FNM-ALK-V Photoelectric Smoke
Sensor is particularly suited to detecting optically dense
smoke typical of fires involving materials such as soft
furnishings, plastic, foam or other similar materials which
tend to smolder and produce large visible smoke particles.
Hochiki's unique design allows fast response to flaming
fires as well as smoldering fires while eliminating false
alarms.

OPERATION
The detection chamber consists of a light emitting diode
(LED) and photodiode arrangement. The chamber is
designed such that light emitted by the LED cannot
Shown without base normally reach the photo diode. In the event of fire,
particles of smoke enter the chamber and scatter the
STANDARD FEATURES light. As the smoke level increases, the scattering effect
• Low Profile - Only 2.0" high, including base increases, causing more light to hit the photodiode. The
chamber contains a unique baffle design which allows
• Simple and reliable device addressing method smoke to enter the chamber while preventing external
• Automatic compensation for sensor contamination light from affecting the photodiode. The photodiode input
• Built-in fire test feature level is sampled to sense smoke density.
• Uses the noise immune Digital Communication
Protocol (DCP), which utilizes interrupts for fast When the smoke density exceeds a preset threshold
response to fires the sensor transmits an interrupt to the fire control panel
• Two built-in power/alarm LED's indicating a fire condition. The fire alarm control panel
• Programmble Non-polling LED's can adjust the sensor threshold to compensate for
contamination.
• Non-directional smoke chamber
• Vandal resistant security locking feature Up to 127 devices are permitted on each loop. A sensor
• Removable smoke labyrinth for cleaning or address can be set by a hand held programming unit.
replacement The sensor mounts to an electronics free base and
incorporates a locking mechanism for secure installation.
The base provides mounting slots, terminals for field wiring
SPECIFICATIONS and a third contact for a remote indicator/LED. The sensor
Operating Voltage 17-41 VDC incorporates dual LED's for easy viewing of sensor status.
Standby Current 390μA
Alarm Current 800μA ENGINEERING SPECIFICATIONS
Transmission Method DCP - Digital
Communication Protocol The contractor shall furnish and install where indi-
Maximum Humidity 95% RH Non-Condensing cated on the plans, photoelectric sensors HOCHIKI
UL Ambient Installation 32°F to 100° F America Model FNM-ALK-V. The combination sen-
Temperature Range (0° C to 37.8° C) sor head and twist lock base shall be UL listed com-
patible with a UL listed fire alarm control panel.
Operating Temperature 14°F to 122° F
Range (-10° C to 50° C)
Sensitivity Range 0.5 - 3.8%/FT@300FPM PRODUCT LISTINGS
0.5 - 2.74%/FT@2000FPM
0.5 - 2.68%/FT@4000FPM
Air Velocity Range 0-4000 fpm
Color & Case Material Bone PC, Black / ABS Blend
Weight 3.4oz (5.1 oz. with 4" base) 161.002/A58/0
Bases 4" FNM-NSA-4 S1383
6" FNM-NSA-6
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F00159 09/2012
ENGINEERING SPECIFICATIONS, continued
The base shall permit direct interchange with the HOCHIKI America FNM-ACA-V multi-criteria sensor.

The sensitivity of the sensor shall be capable of being measured by the control panel.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.

BASES
The FNM-NSA-4 and the FNM-NSA-6 mounting bases are electronics free and are a simple rugged design with screw
terminals for wiring connections. A common mounting base allows sensor interchange and maintains loop continuity
when sensors are removed. A simple anti-tamper head locking system is provided which is enabled by removing a small
plastic tab on the back of the sensor. Once locked, the head can be removed using a small diameter screw driver.

TYPICAL WIRING DIAGRAMS

NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components
(DCP sensors FNM-ALK-V and FNM-ACA-V, bases and modules), to be used
concurrently in a system's signaling line circuit.

U.L.
LISTED
COMPATIBILE (+)
CONTROL
PANEL

(-)

U.L. (+)
LISTED
POWER *
LIMITED
SUPPLY

* - OPTIONAL WIRING CONFIGURATIONS FOR REMOTE OUTPUT

(+)
U.L.
LISTED
COMPATIBILE
CONTROL
PANEL

(-)
U.L.
LISTED
POWER
LIMITED
SUPPLY (+)

Hochiki America Corporation FNM-ALK-V Specifications subject to change without notice.


FNM-ACA-V ANALOG MULTI-CRITERIA SENSOR
APPLICATION
The HOCHIKI America FNM-ACA-V Multi-Criteria Smoke
Sensor is particularly suited for detecting smoke produced
by a wide range of combustibles found in various
applications. Temperature monitoring is achieved by a
thermistor placed for optimum sensitivity. Hochiki's unique
design allows fast response to flaming fires as well as
smoldering fires while minimizing false alarms.

OPERATION
The FNM-ACA-V chamber consists of a light emitting diode
(LED) and photodiode arrangement. The chamber is
designed such that light emitted by the LED cannot normally
reach the photodiode. In the event of fire, particles of smoke
Shown without base enter the chamber and scatter the light. As the smoke level
increases, the scattering effect increases, causing more
STANDARD FEATURES light to hit the photodiode. The chamber contains a unique
design which allows smoke to enter the chamber while
• Low Profile - Only 2.23" high, including base preventing external light from affecting the photodiode. The
• Simple and reliable device addressing method photodiode input level is sampled to sense smoke density.
• Automatic compensation for sensor contamination When the smoke density exceeds a preset threshold the
• Built-in fire test feature sensor transmits an interrupt to the fire control panel
• Uses the noise immune Digital Communication Protocol indicating a fire condition. The fire alarm control panel can
(DCP), which utilizes interrupts for fast response to fires adjust the sensor threshold to compensate for contamination.
• Two built-in power/alarm LED's
The FNM-ACA-V Heat portion incorporates a highly linear
• Programmable Non-polling LED's thermistor circuit, with the thermistor mounted externally.
• Non-directional smoke chamber The specially designed cover protects the thermistor while
• Vandal resistant security locking feature allowing maximum air flow. The thermistor circuit produces
• Removable smoke labyrinth for cleaning or replacement a voltage proportional to temperature which is scaled, and
• Compatible with the analog sensors transmitted as a digitally encoded value to the control panel.
When the ambient temperature exceeds a pre-
programmed threshold (fixed temperature), the sensor
transmits an interrupt to the control panel indicating a fire
SPECIFICATIONS alarm. The fire alarm control panel can adjust the sensor
Operating Voltage 17-41 VDC threshold for different Standard's requirements.
Standby Current 450μA
Alarm Current 540μA Up to 127 devices are permitted on each loop. A sensor
Transmission Method DCP - Digital address can be set by a hand held programming unit. The
Communication Protocol
Operating Temperature 14°F (-10°C) - 122°F (50°C)
sensor mounts to an electronics free base and incorporates
UL Temperature Range 135°F (57°C) - 150°F (65°C) a locking mechanism for secure installation. The base
Storage Temperature -4°F (-20°C) - 140°F (60°C) provides mounting slots, terminals for field wiring and a third
Range contact for a remote indicator/LED. The sensor incorporates
Maximum Humidity 95% RH Non-Condensing dual LED's for easy viewing of sensor status.
Color & Case Material Ivory
Weight 4.2 oz (5.9 oz. with 4" base)
Dimensions 3.9"W x 1.8"H PRODUCT LISTINGS
Bases 4" FNM-NSA-4
6" FNM-NSA-6

161.002/A58/0
S1383

Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0160 09/2012
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, Multi-Criteria sensor HOCHIKI America Model
FNM-ACA-V. The combination sensor head and twist lock base shall be UL listed compatible with the UL listed fire alarm
control panel.

The base shall permit direct interchange with the HOCHIKI America FNM-ALK-V Photoelectric type sensor.
The sensitivity of the sensor shall be capable of being measured by the control panel.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.

BASES
The HOCHIKI America FNM-NSA-4 and the FNM-NSA-6 mounting bases are electronics free and are a simple rugged
design with screw terminals for wiring connections. A common mounting base allows sensor interchange and maintains
loop continuity when sensors are removed. A simple anti-tamper head locking system is provided which is enabled by
removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using a small diameter
screw driver.

TYPICAL WIRING DIAGRAMS

U.L.
LISTED
COMPATIBILE (+)
CONTROL
PANEL

(-)

U.L. (+)
LISTED
POWER *
LIMITED
SUPPLY

* - OPTIONAL WIRING CONFIGURATIONS FOR REMOTE OUTPUT

(+)
U.L.
LISTED
COMPATIBILE
CONTROL
PANEL

(-)
U.L.
LISTED
POWER
LIMITED
SUPPLY (+)

NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components (DCP sensor FNM-ALK-V, bases and
modules), to be used concurrently in a system's SLC (Signaling Line Circuit).
Hochiki America Corporation FNM-ACA-V Multi-Criteria Specifications subject to change without notice.
Sensor
ANALOG SENSOR BASES
SPECIFICATIONS
Security Feature Plastic Tamper-lock
Color & Material Bone PC / ABS Blend
Dimensions FNM-NSA-6: 6 inches
FNM-NSA-4: 4 inches
Compatible Detectors FNM-ALK-V, FNM-ACA-V

APPLICATION

The HOCHIKI America FNM-NSA-4 and the FNM-NSA-


FNM-NSA-4 6 mounting bases are electronics free and contain a
simple rugged design with screw terminals for wiring
connections. A common mounting base allows sensor
interchange and maintains loop continuity when sen-
sors are removed. A simple anti-tamper head locking
system is provided which is enabled by removing a small
plastic tab on the back of the sensor. Once locked, the
head can only be removed using a small diameter screw
driver.

OPERATION

The FNM-NSA-4 and FNM-NSA-6 are designed specifi-


FNM-NSA-6 cally for use with the Hochiki NS Analog models FNM-
ALK-V and FNM-ACA-V.
STANDARD FEATURES
• UL & ULC Listed The FNM-NSA-4 and FNM-NSA-6 common mounting
• Designed for use with all NS analog sensors bases allows for complete compatibility for all of the
• Available in 4 and 6 inch models Hochiki NS Series Analog sensors. The bases are
• Contains a security locking tab for tamper lightweight and very thin, providing a low profile once
protection installed. The solder-less screw terminals enable quick
and easy wiring connections.

PRODUCT LISTINGS

161.002/A58/0
S1383
Continued on back.
Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0161 07/2010
ENGINEERING SPECIFICATIONS

The base shall permit direct interchange with the HOCHIKI America FNM-ALK-V Photoelectric Smoke Sensor and the
FNM-ACA-V Multi-criteria Sensor.

The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.

TYPICAL WIRING DIAGRAMS

U.L.
LISTED
COMPATIBILE (+)
CONTROL
PANEL

(-)

U.L. (+)
LISTED
POWER *
LIMITED
SUPPLY

* - OPTIONAL WIRING CONFIGURATIONS FOR REMOTE OUTPUT

(+)
U.L.
LISTED
COMPATIBILE
CONTROL
PANEL

(-)
U.L.
LISTED
POWER
LIMITED
SUPPLY (+)

NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components (DCP sensors FNM-ALK-V and FNM-ACA-V,
bases and modules), to be used concurrently in a system's signaling line circuit.

Hochiki America Corporation FNM-Analog Sensor Bases Specifications subject to change without notice.
FNM-DIMM - DUAL INPUT MONITOR MODULE

SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current 600µA (Typical)
Consumption 720µA (Alarm)
Programmable Inputs 2 Independent Monitoring Inputs
EOL Device 22K ohms Resistor
Max. Quantity Per Loop 127
Dimensions 4.2”W x 4.7”H x 1.4”D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 4” square electrical box
Relative Humidity 90% RH Non-Condensing

DESCRIPTION
STANDARD FEATURES
The Hochiki Dual Input Monitor Module (FNM-DIMM)
• UL 864 9th Edition Listed is designed for use on a UL listed Fire Alarm Control
• Fast, reliable contact monitoring utilizing the Panel. It provides two independent contact monitor-
ing circuits while only utilizing one address on the
Hochiki DCP (Digital Communications Protocol) SLC loop. Up to 127 devices can be placed on a
• 127 devices can be used per DCP loop single SLC loop. The device address is uniquely
stored on an onboard EEPROM. The module can be
• Bi-colored indicating LED provides module status
programmed to monitor Normally Open (NO) or Nor-
• Dual input contact monitor mally Closed (NC) contact fire alarm and supervisory
• Can be programmed to monitor Normally Open devices. The interrupt driven Digital Communication
(NO) or Normally Closed (NC) contacts Protocol (DCP) combines maximum communication
reliability and fast response to emergency conditions.
• Operates on Class A or Class B SLC loop The module has a single bi-colored LED to indicate
• Accepts up to 14 AWG wire device status. It fits into a standard 4" square or
double gang electrical back box.

PRODUCT LISTINGS

161.002/A58/0
S5694

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0164 09/2012
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, Hochiki FNM-DIMM addressable contact
monitoring modules. The modules shall be UL listed and compatible with the Hochiki Digital Communications
Protocol (DCP) supporting control panel loops. The device address shall be electrically programmable and stored in
EEPROM. The contact module must be suitable for mounting in a standard 4" square electrical box or double gang.
The contact module must provide a bi-colored LED to indicate device status.

WIRING DIAGRAM

E.O.L. DEVICE 22K Hochiki America Corporation


PART NUMBER FNM-DIMM OUT TO NEXT MODULE
0400-01000 TB2 Dual Input Monitor Module
TYPICAL WIRING FOR N/O CONTACTS ONLY SER. NO. XXXXXXXXX
+
TB1
Input A
E.O.L. DEVICE 22K
PART NUMBER
0400-01000 S U.L. LISTED
COMPATIBLE
+ SC
FIRE CONTROL
ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE Input B PANEL
DEVICES MAY BE USED, SUBJECT TO NFPA AND AHJ
REQUIREMENTS.
Dual Input Monitor
Module ALL WIRING SHOWN IS SUPERVISED
AND INHERENTLY POWER LIMITED.

Hochiki America Corporation FNM-DIMM Specifications subject to change without notice.


FNM-FRCMA - FAST RESPONSE CONTACT MODULE
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current Consumption 630μA (Typical)
6.3mA (Alarm)
Maximum Quantity Per Loop 127
Dimensions 4.2"W x 4.7"H x 1.4"D
Ambient Temperature 32°F (0°C) ~ 120° F (49°C)
Mounting 4" square electrical box
Relative Humidity 90% RH Non-condensing

DESCRIPTION
The Hochiki FNM-FRCMA Fast Response Contact Moni-
toring Modules are designed to be used with pull stations,
STANDARD FEATURES water flow switches, and other applications requiring the
monitoring of dry contact alarm initiating devices. The in-
• Single input contact monitor terrupt driven Digital Communications Protocol (DCP) com-
• Fast, reliable contact monitoring utilizing the bines maximum communication reliability and fast response
Hochiki DCP (Digital Communications Protocol) to emergency conditions. Two different mounting configu-
• Two different mounting configurations rations are provided to meet a wide range of applications.
The FNM-FRCMA contact monitoring module does not re-
• 127 devices can be used per DCP loop quire a separate 24 VDC power source.
• Bi-colored indicating LED provides module status
(Both Models)
Each addressable contact monitoring module is
• Can be programmed to monitor Normally Open programmed with its own unique Signaling Line Circuit
(NO) or Normally Closed (NC) contacts in Class B (SLC) loop address. The device address is electrically
• Operates on Class A or Class B SLC loop programmable and stored on onboard EEPROM. Up to
• Accepts up to 14 AWG wire 127 devices can be placed on the Hochiki DCP SLC loop.
The module supervises the wiring to the contact with an
• UL 864 Listed End Of Line (EOL) resistor in Class B mode. It can be
programmed to monitor Normally Open (NO) or Normally
Closed (NC) contacts. If a fault condition occurs in the
wiring, the module sends a trouble status signal to the fire
alarm control panel. When a change of status (contact
changes state) is sensed by the FNM-FRCMA, it sends
an interrupt to the Fire Alarm Control Panel indicating that
an alarm has occurred.

PRODUCT LISTINGS

161.002/A58/0
S5694
Specifications subject to change without notice.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0163 09/2012
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans, addressable contact monitoring modules Hochiki
FNM-FRCMA. The modules shall be UL listed and compatible with the Fire alarm control panel. The device address
shall be electrically programmable and stored in EEPROM.

The FNM-FRCMA shall be supplied with a plastic face plate and shall be suitable for mounting to a 4" square or double
gang electrical back box. The FNM-FRCMA shall provide a monitor LED that is visible through the face plate.

WIRING DIAGRAM

WIRING DIAGRAMS FOR CLASS A (STYLE D) WIRING NOTE: CLASS A can only monitor N/O contacts

TB2

TB1 AND TB2 SHOWN IS SUPERVISED


AND INHERENTLY POWER LIMITED
FIGURE 2A.

WIRING DIAGRAMS FOR CLASS B (STYLE B) WIRING


TYPICAL WIRING FOR N/O CONTACTS IN CLASS B

E.O.L. DEVICE
PART NUMBER
0400-03180

TB2

HOCHIKI AMERICA CORP.


ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE E.O.L. DEVICE
DEVICES MAY BE USED . DO NOT MIX FIRE ALARM PART NUMBER
INITIATING OR SUPERVISORY ON THE SAME MODULE 0400-03180

FIGURE 2B

TYPICAL WIRING FOR N/C CONTACTS


(N/C AVAILABLE ONLY FOR CLASS B)
TB1 TB2

NOTE: If configured for class B, N/C contacts, this cannot be


an alarm or supervisory.

E.O.L. DEVICE HOCHIKI AMERICA CORP.


PART NUMBER
0400-03180 E.O.L. DEVICE
PART NUMBER
0400-03180
FIGURE 2C
TB1 AND TB2 SHOWN IS SUPERVISED
AND INHERENTLY POWER LIMITED

Hochiki America Corporation FNM-FRCMA Specifications subject to change without notice.


FNM-R2ML - DUAL RELAY MODULE

SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current Consumption 350μA (Typical)
405μA (Alarm)
Contacts 2 Independently Controlled Form C
FNM-R2ML: 2A @ 30VDC / 0.5A @ 120 VAC

SCI On Resistance
40m ohm Max. (Normal Condition)
SCI Fault Detection Threshold 12 volts (Typical)
SCI Isolation Current
(Short Circuit Condition) 10mA (Typical)
Maximum Quantity Per Loop 127
Dimensions 4.2"W x 4.7"H x 1.4"D
STANDARD FEATURES
Ambient Temperature 32°F (0°C) ~ 120°F (49°C)
• Provides two independently configurable Form C Mounting 4" square electrical box
contacts per address
Relative Humidity 90% RH Non-condensing
• Contacts are rated as follow:
FNM-R2ML: 2A @ 30 VDC / 0.5A @ 120 VAC
DESCRIPTION
• Up to127 devices can be used on each SLC loop
• Visible Bi-colored LED is software controlled and The Dual Relay Modules (FNM-R2ML) have been designed
can be programmed to blink red or green when to provide flexibile and quick response to emergency
polled. The LED can be latched on when activated. conditions. The FNM-R2ML allows independent control of
(For All Models) two form C contacts for a variety of normally open and
• Programming is highly flexible providing 16 priority normally closed contact applications such as fan operation,
states plus zoning capability elevator recall, door closure, and auxiliary notification.
• Operates on Class A or Class B SLC loop
• UL 864 Listed Each FNM-R2ML module provides independent control of
two Form C contacts while utilizing one SLC (Signaling Line
Circuit) address. The FNM-R2ML module have a highly
configurable programming algorithm that allows the user to
set up groups of devices (zoning) for simultaneous operation
of multiple FNM-R2ML module. Each module has 16 priority
states that are programmed. The operating parameters are
PRODUCT LISTINGS maintained by the module and do not require individual
communication with the control panel during the emergency
condition to operate. The control panel broadcasts the
control command on the SLC loop and the FNM-R2ML
161.002/A58/0 module do the rest based on their custom configuration.
S5694 Since mechanically latching relays are used within the
FNM-R2ML module, a separate 24VDC power source is not
Specifications subject to change without notice. required.
Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0162 09/2012
ENGINEERING SPECIFICATIONS

The contractor shall furnish and install where indicated on the plans, the Hochiki FNM-R2ML addressable relay
modules. The modules shall be UL listed compatible with Hochiki Digital Communications Protocol (DCP)
supporting control panel loops. The relay module must provide two Form C dry contacts rated as follows: FNM-
R2ML - 2A @ 30 VDC or 0.5A @ 120 VAC. The relay module must be suitable for mounting in a standard 4" square
electrical box. The relay module must provide a bi-colored LED for indication of status.

WIRING DIAGRAM

Hochiki America Corporation


FNM-R2ML NO1
TB2 S, SC WIRING SERIAL NO. XXXXXXXXX
POWER LIMITED
OUTPUT TO NEXT INTERFACE COM1 SET 1
MODULE IN THE SLC LOOP POWER
LIMITED
For Proper Installation,
see HA-06-148 01/09 NC1
NON
POWER (FORM "C" CONTACTS)
LIMITED (NON-SUPERVISED)
NO2
U.L. LISTED SC -
COMPATIBLE CROSS OUT
TYPE NOT
FIRE CONTROL S + USED
COM2 SET 2
PANEL
NC2

FIGURE 2.
WIRING DIAGRAM

Hochiki America Corporation FNM-R2ML Specifications subject to change without notice.


FNM-AMS-KL-LP - ADDRESSABLE MANUAL PULL STATIONS

SPECIFICATIONS
Operating Voltage (SLC) 17~41 VDC
Average Current Consumption 550uA (Typical)
660uA (Alarm)
Ambient Temperature 32°F (0 °C) ~ 120°F (49°C)
Maximum Humidity 90% RH, non-condensing
Dimensions 3.4"W x 4.8"H x 2.0"D
Mounting Single gang or 4" square
electrical box

DESCRIPTION
FNM-AMS-KL-LP
The FNM-AMS-KL-LP are the Hochiki America series
of addressable manual pull stations that provide a fast
and practical means of manually initiating a fire alarm
STANDARD FEATURES signal. Both single action and dual action manual pull
stations are available. Resetting of the pull station
• Addressable integrated design requires either a Cat 30 key or a 1/8" hex key (depending
• All metal construction upon the model used).
• Single and dual action models available
• Extremely easy to operate The dual action DCP-AMS-KL-LP Lift and Pull cover must
• Bi-colored status LED indicates Standby and be lifted before pulling down on the pull station handle
Alarm conditions to activate an alarm condition. Once the pull station is
• Address is programmable in EEPROM activated, the handle cannot be put back into a normal
standby condition without using the key operated reset
• Address can be programmed when installed
feature.
• Key lock or hex key lock models available
• Enclosed switch with glass rod (included) The FNM-AMS-KL-LP series is electronically
• Terminals accept up to 14AWG wire addressable and includes a bi-colored status LED. The
• Surface mount back box available LED blinks green indicating normal communication with
• ADA compliant (except LP models) the DCP compatible SLC loop. When an alarm condition
is actuated by pulling the handle, the LED will latch
Red to indicate the alarm condition.

PRODUCT LISTINGS

161.002/A58/0
S6512

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0166 09/2012
ENGINEERING SPECIFICATIONS
Manual pull station shall be Hochiki addressable dual action model FNM-AMS-KL-LP. Models shall be made of 14
AWG CRS and painted with Red enamel. The words Fire Alarm shall be in a contrasting color and be embossed text
1/2" tall. The electronics shall be fully integrated into the manual pull station requiring only connection to the SLC
loop of the control panel. Programming of the manual pull station address must be possible with the manual pull
station fully installed.

WIRING DIAGRAMS

Hochiki America Corporation


OUT TO
NEXT FNM-AMS-KL-LP
MODULE Addressable Manual Pull Station
Ser. No.
SC- S+

S+ SC-
For Proper Installation, see HA-06-135 Rev 12/05
S6512

NON-CODED ALARM BOX


36CC

UL
Listed + S
Hochiki
DCP - SC
Compatible
Panel

TYPICAL WIRING DIAGRAM EXAMPLE, CONNECTED


TO A COMPATIBLE LISTED CONTROL PANEL

Class B (Style 4)
Hochiki America Corporation Hochiki America Corporation Hochiki America Corporation
FNM-AMS-KL-LP FNM-AMS-KL-LP FNM-AMS-KL-LP
Addressable Manual Pull Station Addressable Manual Pull Station Addressable Manual Pull Station
Ser. No. Ser. No. Ser. No.

S+ SC- S+ SC- S+ SC-


For Proper Installation, see HA-06-135 Rev 12/05 For Proper Installation, see HA-06-135 Rev 12/05 For Proper Installation, see HA-06-135 Rev 12/05

S6512 S6512 S6512


+ S NON-CODED ALARM BOX NON-CODED ALARM BOX NON-CODED ALARM BOX
UL 36CC 36CC 36CC

Listed
Hochiki
- SC
DCP
+ S
Compatible
Panel - SC
Class A Return (Style 6)

Hochiki America Corporation FNM-AMS-KL-LP Specifications subject to change without notice.


12-24SIR - CARBON MONOXIDE DETECTOR

SPECIFICATIONS
Models: 12-24SIR
Rated Voltage 10 - 28 VDC
Alarm Current 25mA
Standby Current 60uA
Relay Contact Voltage 30 VDC
Relay Contact Current 0.1A
Wiring Gauge 14 AWG - 22 AWG
Operating Temperature 40°F(4.4°C) ~ 100°F(37.8°C)
Relative Humidity 7.5 ~ 95%, Non-Condensing
Color Bone
Dimensions 5" D x 1.75" H
(127mm x 44.45mm)
Weight 9.4 oz

APPLICATION
STANDARD FEATURES
The 12-24SIR carbon monoxide (CO) detector is suited
• UL Listed for installations where CO may be expected. It responds
• 12/24VDC input power to the toxic CO gas that results from incomplete
• Reduces false alarm with its superior solid-state combustion, such as that emitted from appliances,
infrared sensor technology furnaces, fireplaces and auto exhaust. This detector is
• Low standby Current draw of 60uA designed to detect carbon monoxide gas from any source
• Bulit-in sounder with 85dB @ 10ft. of combustion.
• Temporal 4
• 6 year limited warranty
• Built-in self test
OPERATION
• Continuous supervision of CO sensor and alarm
circuit The 12-24SIR CO detector uses a solid-state infrared
• 1 Alarm Relay & 1 Trouble Relay (SIR) carbon monoxide sensor technology. The IR
• May be mounted on wall or ceiling detector monitors changes in photon transmittance of
the sensors, which are inversely related to levels of CO
concentrations in the air. For additonal information,
please refer to the 12-24SIR installation instruction
manual.

PRODUCT LISTINGS
• UL Listed (UL 2075)
• CSFM Approved

Specifications subject to change without notice.

Find latest revision at www.hochiki.com


Hochiki America Corporation
7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0189 10/2013
RFD-2000X - ULTRAVIOLET & INFRARED FLAME DETECTOR

SPECIFICATIONS
Models: RFD-2000X
Rated Voltage 17 - 32 VDC
Alarm Current 20mA
Relay Contact Voltage 28 VDC max.
Relay Contact Current 2A max.
Detector Output 4-20mA
Wiring Gauge 14 AWG - 24 AWG shielded
Range of View 100 ft. (30m)
Field of View 90° Horizontal & Vertical
IP Rating IP67
Operating Temperature -40°C(-40°F) ~ 75°C(167°F)
Storage Temperature -50°C(-50°F) ~ 80°C(176°F)
Relative Humidity 95%, Non-Condensing
Color / Material Metal / Stainless Steel 316
Dimensions 5.3" W x 4.6" H x 4.7" D
(134mm x 117mm x 120mm)
STANDARD FEATURES Weight 3.4kg
• FM Approved
• Built-in Ultra violet and Infrared flame Sensors APPLICATION
• Explosion Proof (ATEX Ex d IIB + H2)
• Range of view up to 100ft. (30m) The RFD-2000X (explosion proof) Ultra Violet Infrared
• Reduces false alarm by built-in combination filters flame detector is suited for installation where open flame
and signal processing techniques fires may be expected. It responds to the light
• IP67 Rated for water and dust tight protection frequencies emitted from flames during combustion. This
• 4-20mA Output detector is used to detect flames from burning aviation
• 3 built-in relays (Alarm, Fault & Warning Alarm) fuels, butane, grain & feeds, hydrogen, paper, natural
gas, and petrol.

OPERATION
The RFD-2000X (Explosion proof) detector discriminates
between flames and other light sources by responding
only to set optical wavelenghts and flame flicker
frequencies. The built-in filters and signal processing
PRODUCT LISTINGS techniques help reduce false alarms due to flickering
sunlight. Rezontech's flame detector test unit (Test
• FM Approved (FM 3260) Lamp_TL-205) can be utilized to test the flame detector.
• ATEX Ex d IIB + H2 (Explosion proof)
Class I division 1 Group B,C and D
Class II division 1 Groups E, F and G ACCESSORIES
Class III
• IP67 (Water and dust tight)
• Sun Shield
• Air Shield
• Braket_BK-2

Specifications subject to change without notice.

Find latest revision at www.hochiki.com


Hochiki America Corporation
7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0183 06/2013
SOLO 200
UNIVERSAL DETECTOR REMOVAL TOOL

SPECIFICATIONS
Model Solo 200
Compatible Detector 2.5" - 4.5" dia.
Sizes (65mm - 110mm)
Color Black
Weight 2.42 lbs.

DESCRIPTION
Compatible with most detectors and sensors, the Solo
200 features color-coded heads which rotate to provide
a combination of settings and lock into place to fit
different sized detectors and sensors.
Shown without telescopic pole

STANDARD FEATURES
• Compatible with all Hochiki conventional detectors
and analog sensors.
• Universal Design - suits most detectors and
sensors of other manufacturers
• Color coded tri-grip heads are spring loaded
• Adjustable tri-grip
• Suitable for use on angled ceilings
• Lightweight

ACCESSORIES
Shown with teslescopic pole • Solo 100 - 15 ft. telescopic pole (sold separately)
• Solo 108 - 8 ft. telescopic pole (sold separately)
• Solo 101 - 4 ft. telescopic pole (sold separately)

Specifications subject to change without notice.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0191 01/2014
TH Series - Linear Heat Detection
SPECIFICATION
External Diameter 0.138 inch (3.5 mm)
Dielectric Withstand 500VDC
Conductors Tin plated copper coated steel
Electrical Rating 30VAC (42.4VDC) 10 A
Conductor Min: 88.1 ohms per 1000m
Resistance Max: 92.1 ohms max per 1000m
Conductor Extrusion Temperature Sensitive Polymer
External Sheath Color coded polymer
Lead & Cadmium free / UV
resistant
Tensile Strength 1,700 min (N/mm2)
Capacitance TH68: 150pF/m
TH88: 97pF/m
TH105:88pF/m
STANDARD FEATURES Inductance TH68: 960nH/m
TH88: 570nH/m
• UL listed & FM approved
TH105:1060nH/m
• Available in three temperature models
• Available in 328, 656, 1,640 & 3,280ft reels Impedance TH68: 80 ohms
• Available in 164ft reel for TH68 model only TH88: 75 ohms
• Low cost & fast response TH105: 110 ohms
• Compatible with HCA Series FACP & CZM Module Min. Bend Radius 4.0 inch (100 mm)
• UL Listed for up to 35ft (10.6m) spacing
• 92.1 ohms/conductor/km maximum resistance
• Localized overheat detection DESCRIPTION
• Not affected by RFI or EMC
• ATEX certified - zener barrier in hazardous areas The TH series digital linear temperature sensing cable is
• Ambient temperatures range: manufactured as 2 twisted and tensioned tin plated copper
TH68: -40F (-40C) ~ 139F (59C) coated steel conductors. Each conductor is then extruded
TH88: -40F (-40C) ~ 171F (77C) with a temperature sensitive polymer before the application
TH105: -40F (-40C) ~ 198F (92C) of an outer sheath of flame retardant high temperature
material.
• Alarm temperatures:
TH68: 155F (68C)
TH88: 190F (88C) OPERATION
TH105: 221F (105C)
• Section replacement of sensor cable after alarm At a pre-determined temperature, inner insulation softens
• Continuously monitors 100% of sensor length allowing the two conductors to come into contact with each
other to produce the required alarm signal. Any break in
conductors at temperatures below the alarm threshold
APPLICATIONS generates an open circuit trouble signal. No minimum
length exposure is required for the alarm rating.
• Underfloor (server rooms)
• Mechanical / Electrical control rooms
• Hazadous areas PRODUCT LISTINGS
• Warehouse
• Parking structures • UL & ULC Listed
• Cable trays • FM Approved
• Tunnel protection • CSFM Listed

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com F0184 07/2014
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
ADEMCO
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
VISTA 100 N/A A B 10 2K OHMS SLR-835B-2 HD-6 N/A N/A
VISTA 100 N/A A B 10 2K OHMS SLR-835B-2W HD-6 N/A N/A
VISTA 100 N/A A B 10 2K OHMS SLR-835BH-2 HD-6 N/A N/A
VISTA 100 N/A A B 10 2K OHMS SLR-835BH-2W HD-6 N/A N/A
VISTA 100-24 N/A A B 10 2K OHMS SLR-835B-2 HD-6 N/A N/A
VISTA 100-24 N/A A B 10 2K OHMS SLR-835B-2W HD-6 N/A N/A
VISTA 100-24 N/A A B 10 2K OHMS SLR-835BH-2 HD-6 N/A N/A
VISTA 100-24 N/A A B 10 2K OHMS SLR-835BH-2W HD-6 N/A N/A
VISTA 20HWSE N/A A B 10 2K OHMS SLR-835B-2 HD-6 N/A N/A
VISTA 20HWSE N/A A B 10 2K OHMS SLR-835B-2W HD-6 N/A N/A
VISTA 20HWSE N/A A B 10 2K OHMS SLR-835BH-2 HD-6 N/A N/A
VISTA 20HWSE N/A A B 10 2K OHMS SLR-835BH-2W HD-6 N/A N/A
VISTA 40 N/A A B 10 2K OHMS SLR-835B-2 HD-6 N/A N/A
VISTA 40 N/A A B 10 2K OHMS SLR-835B-2W HD-6 N/A N/A
VISTA 40 N/A A B 10 2K OHMS SLR-835BH-2 HD-6 N/A N/A
VISTA 40 N/A A B 10 2K OHMS SLR-835BH-2W HD-6 N/A N/A
VISTA 50PUL N/A A B 10 2K OHMS SLR-835B-2 HD-6 N/A N/A
VISTA 50PUL N/A A B 10 2K OHMS SLR-835B-2W HD-6 N/A N/A
VISTA 50PUL N/A A B 10 2K OHMS SLR-835BH-2 HD-6 N/A N/A
VISTA 50PUL N/A A B 10 2K OHMS SLR-835BH-2W HD-6 N/A N/A
VISTA 20SE N/A A B 10 2K OHMS SLR-835B-2 HD-6 N/A N/A
VISTA 20SE N/A A B 10 2K OHMS SLR-835B-2W HD-6 N/A N/A
VISTA 20SE N/A A B 10 2K OHMS SLR-835BH-2 HD-6 N/A N/A
VISTA 20SE N/A A B 10 2K OHMS SLR-835BH-2W HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

ADT
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HS-2-RB HB-10
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HS-22D HB-3
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HSB-220 HB-56
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HSB-224 HB-53
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 YBA-M22 HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HS-2-RB HB-10
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HS-22D HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HSB-220 HB-56
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HSB-224 HB-53
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 YBA-M22 HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HS-2-RB HB-10
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HS-22D HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HSB-220 HB-56
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HSB-224 HB-53
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HS-2-RB HB-10
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HS-22D HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HSB-220 HB-56
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HSB-224 HB-53
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HS-2-RB HB-10
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HS-22D HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HSB-220 HB-56
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HSB-224 HB-53
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HS-2-RB HB-10
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HS-22D HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HSB-220 HB-56
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HSB-224 HB-53
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;9W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 YBA-M22 HB--3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

ADVANTOR
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-200D HB-20
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-220D HB-3
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-221D HB-4
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-224D HB-5
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-200 HB-55
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-220 HB-56
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-221 HB-54
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-224 HB-53
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-200D HB-20
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-220D HB-3
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-221D HB-4
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-224D HB-5
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-200 HB-55
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-220 HB-56
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-221 HB-54
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-224 HB-53
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-200D HB-20
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-220D HB-3
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-221D HB-4
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-224D HB-5
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-200 HB-55
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-220 HB-56
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-221 HB-54
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-224 HB-53
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

ANSUL
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
AUTOPULSE FOUR 415413 REV.4 B 45 417213 DCA-135 N/A HSC-21L HB-60
AUTOPULSE FOUR 415413 REV.4 B 45 417213 DCA-190 N/A HSC-21L HB-60
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SIH-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SIH-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SIH-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 HS-21D HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 HSC-224R HB-73
AUTOPULSE FOUR 415413 REV.4 B 45 417213 DCA-135 N/A YBA-M21 HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 DCA-190 N/A HSC-21L HB-60
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HSC-21L HB-60
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 HS-21D HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 HSB-21 HB-51
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 HSC-224R HB-73
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 YBA-M21 HB-2
AUTOPULSE IQ301 MMX-2, M3-TW A B 24 3.9K 1400 A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1451 A B401 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1451 A B401B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 1451 A B406B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1451DH A DH400 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1851DH A DH1851DC A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2400 A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 2400AIT A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 2400AT A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2400TH A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451 A B401 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451 A B401B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451 A DH400 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451TH A B401 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451TH A B401B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 2451TH A B406B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2851DH A DH2851DC A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SIH-24F HD-3 HS-22D HB-3
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K SLD-24F HD-3 HS-2-RB HB-10
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SLK-24F HD-3 HS-22D HB-3
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

C & K SYSTEMS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
238,2316 ZONE 8 NONE A 10 2.2K SLK-12 HD-4 HSB-12-1 HB-80
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 5-Mar-2003
LISTED AFTER MARCH 1, 1989

CADDX
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
NX6, NX8 3800-0001 MDL NO A 20 680 OHMS SLR-835,-835W HD-3 NS4-220,NS6-220 HB-3
NX6,NX8 3800-0001 MDL NO A 20 680 OHMS SLR-835B-2 HD-6 N/A N/A
NX8-E 3800-0020 MDL NO A 20 680 OHMS SLR-835,-835W HD-3 NS4-220,NS6-220 HB-3
NX8-E 3800-0020 MDL NO A 20 680 OHMS SLR-835B-2 HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

CHEMETRON
2-Wire Compatibility Listings
PANEL MODEL ZONE MODELZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
MICRO 1-EV A A D 60 N/A SIH-24F HD-3 HS-220D HB-3
MICRO 1-EV A A D 60 N/A SIH-24F HD-3 HS-224D HB-5
MICRO 1-EV A A D 60 N/A SIH-24F HD-3 HS-224RB HB-12
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-220D HB-3
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-220RB HB-12
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-224D HB-5
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-224RB HB-14
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-220D HB-3
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-220RB HB-12
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-224D HB-5
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-224RB HB-14
MICRO1-EV N/A 4 B,D 14 2.7K OHM DCD-135, DCD-190 HD-3 HSC-224L HB-62
MICRO1-EV N/A 4 B,D 14 2.7K OHM DCD-135, DCD-190 HD-3 HSC-224L HB-62
MICRO1-EV N/A 4 B,D 14 2.7K OHM DFE-190 HD-3 HSC-220L HB-64
MICRO1-EV N/A 4 B,D 14 2.7K OHM DFE-190 HD-3 HSC-220L HB-64
MICRO1-EV N/A 4 B,D 14 2.7K OHM SIJ-24 HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SIJ-24 HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24 HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24,-24H HD-3 HSC-220R HB-72
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24,-24H HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24, SLR-24H HD-3 HSC-224R HB-73
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24, SLR-24H HD-3 HSC-224R HB-73
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24H HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-835B-2 HD-6 N/A N/A
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-135 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-135 HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-190 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-190 HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SIJ-24 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SIJ-24 HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SLR-24 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SLR-24 HD-3 NS4-220,NS6-220 HB-3
SG N/A 1 B 33 4.7K OHM SIF-24F HD-3 HS-220D HB-3
SG N/A 1 B 33 4.7K OHM SIH-24F HD-3 HS-220D HB-3
SG N/A 1 B 33 4.7K OHM SLK-24F HD-3 HS-220D HB-3
SG N/A 1 B 33 4.7K OHM SLK-24FH HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

DETECTION SYS.
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 HSC-220L HB-64
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 HSC-220L HB-64
DS9400I, DS9400M N/A A B 20 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM SIJ-24 HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-24H,-24V HD-3 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-24H,-24V HD-3 NS4-100,NS6-100 HB-55
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-24H,-24V HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835 HD-3 NS4-100,NS6-100 HB-55
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835 HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835B-2 HD-6 N/A N/A
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835H HD-5 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 1 2.2K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
DS9400I, DS9400M N/A A B 1 2.2K OHM SIJ-24 HD-3 SBC-2 HB-85
DS9400I, DS9400M N/A A B 1 2.2K OHM SLR-24V HD-3 SBC-2 HB-85
DS9400I, DS9400M N/A A B 1 2.2K OHM SLR-24V HD-3 SBC-2R HB-86

UPDATED 9/11/03
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

DIGITAL MONITOR
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
XR5FC 2--5 A A 22 3.3k SLK12 HD-4 HSB-12-1,-12-1N HB-80
XR5FC 2--5 A A 7 3.3k SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5SL 2--5 A A 22 3.3k SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR5SL 2--5 A A 7 3.3k SLK-835,-835H HD-5 HSB-200,-200N HB-55
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

DMP
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
XR10 10 ON XR10 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR10 10 ON XR10 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR10 10 ON XR10 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 10 ON XR20 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR20 10 ON XR20 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR20 10 ON XR20 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 10 ON XR20 A A 7 3.3K SLR-835B HD-6 NA NA
XR20 715 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 715,-16 A A 7 3.3K SLR-835B HD-6 NA NA
XR20 715,-16,-8 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR20 715,-16-,-8 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR20 715-16 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 715-8 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 715-8 A A 7 3.3K SLR-835B HD-6 NA NA
XR200 10 ON XR200 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 715 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715 OR Z 9 &10 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 715, 715-16 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715,-16 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR200 715,-16 A A 7 3.3K SLR-835B HD-6 NA NA
XR200 715,-16,-8 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HD-4
XR200 715-8 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715-8 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR200 9 & 10 ON XR200 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 9 ON XR200 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 9,10 ON XR200 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR200 9,10 ON XR200 A A 7 3.3K SLR-835B HD-6 NA NA
XR200 XR200 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 XR200 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5FC 2-5 ON XR5FC A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR5FC 2-5 ON XR5FC A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5FC 2-5 ON XR5FC A A 7 3.3K SLR-835 HD-6 NA NA
XR5FC 2-5 ON XR5FC A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR5SL 2-5 ON XR5SL A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR5SL 2-5 ON XR5SL A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5SL 2-5 ON XR5SL A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR5SL 2-5 ON XR5SL A A 7 3.3K SLR-835B HD-6 NA NA
XR6 6 ON XR6 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR6 6 ON XR6 A A 7 3.3K SLR-835B HD-6 NA NA
XR6 715 A A 7 3.3K SLR-835B HD-6 NA NA
XR6 715 ON XR6 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

DSC
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
PC1555 UA000 PC15-1 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC1555 UA000 PC15-1 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC1555 UA000 PC15-1 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
PC4020CF PC4701 PM-2 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC4020CF PC4701 PM-2 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC4020CF PC4701 PM-2 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
PC5010 PC5010 PC5-1 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC5010 PC5010 PC5-1 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC5010 PC5010 PC5-1 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
PC5020 PC5020 PC5-2 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC5020 PC5020 PC5-2 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC5020 PC5020 PC5-2 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

EDWARDS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
5783B N/A 001 B 33 4.7K OHM SIF-24F HD-2 HS-220D HB-3
5783B N/A 001 B 33 4.7K OHM SIH-24F HD-3 HS-220D HB-3
5783B N/A 001 B 33 4.7K OHM SLK-24F HD-3 HS-220D HB-3
5783B N/A 001 B 33 4.7K OHM SLK-24FH HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

F.A.S.T. INC.
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
RZB12-6MFC 240204 5389 B 15 PN260001 SIF-24F HD-2 HS-22D HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SIF-24F HD-3 YBA-M22 HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24F HD-3 HS-22D HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24F HD-3 YBA-M22 HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24FH HD-3 HS-22D HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24FH HD-3 YBA-M22 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

FARADAY
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
852 N/A FOS1 B 30 3.9K OHM DCA-135 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DCA-190 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DCA-190 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DFE-135 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DFE-190 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DCA-135 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DCA-190 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DFE-135 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-190 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DFE-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DFE-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
19000A N/A B D 30 N/A DFE-190 N/A HS-224L HB-18

Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
19000A N/A B D 30 N/A DFE-190 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DCA-135 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DCA-135 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DCA-190 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DCA-190 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DFE-135 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DFE-135 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
19000A EVAC N/A B B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DFE-190 N/A HS-224L HB-18
19000A EVAC N/A B D 30 N/A DFE-190 N/A HS-224L HB-18
2022-FSP NA C B 30 3.9K AL-DCA-135 NA HS-224L HB-18
2022-FSP NA C B 30 3.9K AL-DCA-190 NA HS-224L HB-18
2022-FSP NA C B 30 3.9K AL-DFE-135 NA HS-224L HB-18
2022-FSP NA C B 30 3.9K AL-DFE-190 NA HS-224L HB-18
2022-FSP NA C B 30 3.9K SIF-24F HD-2 AL-HS-224D HB-5
2022-FSP NA C B 30 3.9K SIH-24F HD-3 AL-HS-224D HB-5
2022-FSP NA C B 30 3.9K SLK-24F HD-3 AL-HS-224D HB-5
2022-FSP NA C B 30 3.9K SLK-24FH HD-3 AL-HS-224D HB-5
2042-FSP NA C B 30 3.9K AL-DCA-135 NA HS-224L HB-18
2042-FSP NA C B 30 3.9K AL-DCA-190 NA HS-224L HB-18
2042-FSP NA C B 30 3.9K AL-DFE-135 NA HS-224L HB-18
2042-FSP NA C B 30 3.9K AL-DFE-190 NA HS-224L HB-18
2042-FSP NA C B 30 3.9K SIF-24F HD-2 AL-HS-224D HB-5
2042-FSP NA C B 30 3.9K SIH-24F HD-3 AL-HS-224D HB-5
2042-FSP NA C B 30 3.9K SLK-24F HD-3 AL-HS-224D HB-5
2042-FSP NA C B 30 3.9K SLK-24FH HD-3 AL-HS-224D HB-5
6110-FSP 401310, 311, 312 D B 30 3.9K AL-DCA-135 NA HS-224L HB-18
6110-FSP 401310, 311, 312 D B 30 3.9K AL-DCA-190 NA HS-224L HB-18
6110-FSP 401310, 311, 312 D B 30 3.9K AL-DFE-135 NA HS-224L HB-18
6110-FSP 401310, 311, 312 D B 30 3.9K AL-DFE-190 NA HS-224L HB-18
6110-FSP 401310, 311, 312 D B 30 3.9K SIF-24F HD-2 AL-HS-224D HB-5
6110-FSP 401310, 311, 312 C B 30 3.9K SIH-24F HD-3 AL-HS-224D HB-5
6110-FSP 401310, 311, 312 C B 30 3.9K SLK-24F HD-3 AL-HS-224D HB-5
6110-FSP 401310, 311, 312 C B 30 3.9K SLK-24FH HD-3 AL-HS-224D HB-5
MPC-2000 401310 D B 30 10808 SIF-24F HD-2 HS-224D HB-5
MPC-2000 401310 D D 30 N/A SIF-24F HD-2 HS-224D HB-5
MPC-2000 401310 D D 30 N/A SIH-24F HD-3 HS-224D HB-5
MPC-2000 401310 D B 30 10808 SIH-24F HD-3 HS-224D HB-5
MPC-2000 401310 D D 30 N/A SLK-24F HD-3 HS-224D HB-5
MPC-2000 401310 D B 30 10808 SLK-24F HD-3 HS-224D HB-5
MPC-2000 401310 D D 30 N/A SLK-24FH HD-3 HS-224D HB-5
MPC-2000 401310 D B 30 10808 SLK-24FH HD-3 HS-224D HB-5
MPC-2000 401311 D D 30 N/A SIF-24F HD-2 HS-224D HB-5
MPC-2000 401311 D B 30 10808 SIF-24F HD-2 HS-224D HB-5
MPC-2000 401311 D B 30 10808 SIH-24F HD-3 HS-224D HB-5
MPC-2000 401311 D D 30 N/A SIH-24F HD-3 HS-224D HB-5
MPC-2000 401311 D B 30 10808 SLK-24F HD-3 HS-224D HB-5
MPC-2000 401311 D D 30 N/A SLK-24F HD-3 HS-224D HB-5
MPC-2000 401311 D B 30 10808 SLK-24FH HD-3 HS-224D HB-5
MPC-2000 401311 D D 30 N/A SLK-24FH HD-3 HS-224D HB-5

Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

FIKE
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
RHINO 10-2141, 10-2144 DET220 B, D 50 3.3K OHM DFE-135, -190 N/A HSC-220L HB-64
RHINO 10-2141, 10-2144 DET220 B, D 50 3.3K OHM SLR-24H HD-3 HSC-220R HB-72
RHINO 10-2141, 10-2144 DET220 B, D 50 3.3K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, -2144 DET220 B, D 50 3.3K OHM SLR-835B-2 HD-6 N/A N/A
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 NS4-224, NS6-224 HB-5
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 NS4-224, NS6-224 HB-5
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 NS4-224, NS6-224 HB-5
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 MDL. NO B, D 25 4.3K OHM DCD-135, DCD-190 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 MDL. NO B, D 25 4.3K OHM SIJ-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 MDL NO B, D 25 4.3K OHM SLR-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 MDL. NO B, D 25 4.3K OHM SLR-835B-2 HD-6 N/A N/A
10-038 N/A 038000 B 87 1.5K OHM SIH-24F HD-3 HS-220D HB-3
10-038 N/A 038000 D 87 N/A SIH-24F HD-3 HS-220D HB-3
10-038 N/A 038000 B 87 1.5K OHM SIH-24F HD-3 YBA-M220 HB-3
10-038 N/A 038000 D 87 N/A SIH-24F HD-3 YBA-M220 HB-3
10-038 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 HS-220D HB-3
10-038 N/A 038000 D 87 N/A SLK-24F HD-3 HS-220D HB-3
10-038 N/A 038000 D 87 N/A SLK-24F HD-3 HS-220RB HB-12
10-038 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 HS-220RB HB-12
10-038 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 YBA-M220 HB-3
10-038 N/A 038000 D 87 N/A SLK-24F HD-3 YBA-M220 HB-3
10-039 N/A 038000 D 87 N/A SIH-24F HD-3 HS-220D HB-3
10-039 N/A 038000 B 87 1.5K OHM SIH-24F HD-3 HS-220D HB-3

Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
10-039 N/A 038000 B 87 1.5K OHM SIH-24F HD-3 YBA-M220 HB-3
10-039 N/A 038000 D 87 N/A SIH-24F HD-3 YBA-M220 HB-3
10-039 N/A 038000 D 87 N/A SLK-24F HD-3 HS-220D HB-3
10-039 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 HS-220D HB-3
10-039 N/A 038000 D 87 N/A SLK-24F HD-3 HS-220RB HB-12
10-039 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 HS-220RB HB-12
10-039 N/A 038000 D 87 N/A SLK-24F HD-3 YBA-M220 HB-3
10-039 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 YBA-M220 HB-3
RHINO 10-050 N/A 1 SIH-24F HD-3 HSB-224 HB-53
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SIH-24F HD-3 HSB-220 HB-56
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3K SIH-24F HD-3 HSB-24 HB-53
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SIH-24F HD-3 YBA-M220 HB-3
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3K SIH-24F HD-3 YBA-M224 HB-5
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SLK-24F HD-3 HSB-220 HB-56
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3K SLK-24F HD-3 HSB-224 HB-53
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SLK-24F HD-3 YBA-M220 HB-3
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SIH-24F HD-3 HSB-220 HB-56
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3 SIH-24F HD-3 HSB-220 HB-56
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3K SIH-24F HD-3 HSB-224 HB-53
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SIH-24F HD-3 YBA-M220 HB-3
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3K SIH-24F HD-3 YBA-M224 HB-5
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SLK-24F HD-3 HSB-220 HB-56
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3K SLK-24F HD-3 HSB-224 HB-53
RHINO 10-050 DCM-10-2141 DET220 B, D 50 3.3K SLK-24F HD-3 YBA-M220 HB-3
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3 SLK-24F HD-3 YBA-M224 HB-5
RHINO 10-050 DCM-10-2141 DET B, D 50 3.3K SLK-24F HB-5 YBA-M224 HB-5
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SIH-24F HD-3 HS-221D HB-4
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SIH-24F HD-3 HSB-220 HB-56
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SIH-24F HD-3 HSB-224 HB-53
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SIH-24F HD-3 YBA-M220 HB-3
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SIH-24F HD-3 YBA-M224 HB-5
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SLK-24F HD-3 HS-221D HB-4
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SLK-24F HD-3 HSB-224 HB-53
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SLK-24F HD-3 YBA-M220 HB-3
SHP 10-051 10-2171 MDL NO B, D 25 4.3K SLK-24F HD-3 YBA-M224 HB-5

Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

FIRELITE
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
MP-12 N/A A B, D 11 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MP-12 N/A A B, D 11 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MP-12 N/A A B, D 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MP-12 N/A A B, D 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MP-24 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MP-24 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MP-24 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MP-24 N/A A B 15 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
MP-24 N/A A B 15 2.2K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MP-24 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MS-4012 N/A A B 11 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MS-4012 N/A A B 11 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MS-4412B N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-4412B N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-4412B N/A A B 15 2.2K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-4412B N/A A B 15 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MS-4412B N/A A B 15 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MS-4412B N/A A B 15 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-4412B N/A A B 15 2.2K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-4412B N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MS4412B N/A A B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
MS4412B N/A A B 10 2.2K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-5012 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-5012 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-5012 N/A A B 15 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-5012 N/A A B 15 2.2K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-5012 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 10 2.2K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MS-5012 ZONE 2, 3 A B 11 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MS-5012 ZONE 2, 3 A B 11 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-835B-2 HD-6 N/A N/A
MS-5024,-5024UD N/A A B 10 4.7K OHM SLR-835H HD-5 HSC-220R HB-72
MS-5024,-5024UD N/A A B 10 4.7K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SIJ-24 HD-3 SBC-2 HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-24V HD-3 SBC-2 HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-24V HD-3 SBC-2R HB-85
MS-5210UD CAC-10E A B,D 10 4.7K OHM SLR-835BH-2 HD-6 N/A N/A
MS-5210UD CAC-10E A B,D 10 4.7K OHM SLR-835H HD-5 HSC-220R HB-72
MS-5210UD CAC-10E A B,D 10 4.7K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5210UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-5210UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-5210UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-5210UD N/A A B, D 15 4.7K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-5210UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-5210UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
MS-5210UD N/A A B, D 15 4.7K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-5210UD N/A A B, D 15 4.7K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-5210UD N/A A B, D 15 4.7K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-5210UD N/A A B, D 15 4.7K OHM SLR-835B-2 HD-6 N/A N/A
MS-5210UD N/A,CAC-10F A B, D 1 4.7K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
MS-5210UD N/A,CAC-10F A B, D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
MS-5210UD N/A,CAC-10F A B, D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
MS-5210UD N/A,CAC-10F A B, D 1 4.7K OHM SIJ-24 HD-3 SBC-2 HB-85
MS-5210UD N/A,CAC-10F A B, D 1 4.7K OHM SLR-24V HD-3 SBC-2 HB-85
MS-5210UD N/A,CAC-10F A B, D 1 4.7K OHM SLR-24V HD-3 SBC-2R HB-85
MS4424 N/A A B,D 1 4.7K OHM SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
MS4424 N/A A B,D 1 4.7K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
MS4424 N/A A B,D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
MS4424 N/A A B,D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
MS4424 N/A A B,D 1 4.7K OHM SIJ-24 HD-3 SBC-2 HB-85
MS4424 N/A A B,D 1 4.7K OHM SLR-24V HD-3 SBC-2 HB-85
MS4424 N/A A B,D 1 4.7K OHM SLR-24V HD-3 SBC-2R HB-85
MS-4424B N/A A B 10 4.7K OHM SLR-835H HD-5 HSC-220R HB-72
MS-4424B N/A A B 10 4.7K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-4424, MS4424B N/A A B 15 4.7K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-4424, MS4424B N/A A B 15 4.7K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-4424, MS4424B N/A A B 15 4.7K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-4424, MS4424B N/A A B 15 4.7K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-4424, MS4424B N/A A B 15 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-4424, MS4424B N/A A B 15 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MS-4424, MS4424B N/A A B 15 4.7K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-4424, MS4424B N/A A B 15 4.7K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-4424, MS4424B N/A A B 15 4.7K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-4424, MS4424B N/A A B 15 4.7K OHM SLR-835B-2 HD-6 N/A N/A
RP-1001,-1002 N/A A B, D 20 4.7K OHM DFE-135, -190 N/A HSC-220L HB-64
RP-1001,-1002 N/A A B, D 20 4.7K OHM SLR-24H HD-3 HSC-220R HB-72
RP-1001, -1002 N/A A B, D 20 4.7K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
RP-1001,RP-1002 N/A A B, D 10 4.7K OHM DCD-135, DCD-190 HD-3 HSC-220R HB-72
RP-1001,RP-1002 N/A A B, D 10 4.7K OHM DCD-135, DCD-190 HD-3 NS4-220, NS6-220 HB-3
RP-1001,RP-1002 N/A A B, D 10 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
RP-1001,RP-1002 N/A A B, D 10 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
RP-1001,RP-1002 N/A A B, D 10 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
RP-1001,RP-1002 N/A A B, D 10 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220L HB-64
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220R HB-72
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM DFE-135, -190 HD-3 HSC-220L HB-64
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
S200/S2000 IZ-4F,IZ-8F A B, D 15 4.7K OHM SLR-835B-2 HD-6 N/A N/A
SFP-400,-400B N/A A B, D 20 4.7K OHM DFE-135, -190 HD-3 HSC-220L HB-64
SFP-400,-400B N/A A B, D 20 4.7K OHM SLR-24H HD-3 HSC-220R HB-72
SFP-400,-400B N/A A B, D 20 4.7K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
SFP-400,-400B N/A A B, D 20 4.7K OHM DCD-135, DCD-190 HD-3 HSC-220R HB-72
SFP-400,-400B N/A A B, D 20 4.7K OHM DCD-135, DCD-190 HD-3 NS4-220, NS6-220 HB-3
SFP-400,-400B N/A A B, D 20 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
SFP-400,-400B N/A A B, D 20 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SFP-400,-400B N/A A B, D 20 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
SFP-400,-400B N/A A B, D 20 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3

UPDATED 9/11/03

Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

FIRESCAN
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 HS-221D HB-4
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 HSB-220 HB-56
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 HSB-224 HB-53
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 YBA-220 HB-3
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 YBA-M224 HB-5
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 HS-221D HB-4
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 HSB-220 HB-56
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 HSB-224 HB-53
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 YBA-M220 HB-3
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 YBA-M224 HB-5
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 HS-221D HB-4
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 HSB-220 HB-56
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 HSB-224 HB-53
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 YBA-M220 HB-3
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 YBA-M224 HB-5
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

G.S. BLDG. SYS.


2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
IRC-1 130022 5876 B 15 260001 SIF-24F HD-2 HS-22D HB-3
IRC-1 130022 5876 D 15 N/A SIF-24F HD-2 HS-22D HB-3
IRC-1 130022 5876 B 15 260001 SIF-24F HD-2 YBA-M22 HB-3
IRC-1 130022 5876 D 15 N/A SIF-24F HD-2 YBA-M22 HB-3
IRC-1 130022 5876 B 15 260001 SLK-24F HD-3 HS-22D HB-3
IRC-1 130022 5876 D 15 N/A SLK-24F HD-3 HS-22D HB-3
IRC-1 130022 5876 B 15 260001 SLK-24F HD-3 YBA-M22 HB-3
IRC-1 130022 5876 D 15 N/A SLK-24F HD-3 YBA-M22 HB-3
IRC-1 130022 5876 B 15 260001 SLK-24FH HD-3 HS-22D HB-3
IRC-1 130022 5876 D 15 N/A SLK-24FH HD-3 HS-22D HB-3
IRC-1 130022 5876 B 15 260001 SLK-24FH HD-3 YBA-M22 HB-3
IRC-1 130022 5876 D 15 N/A SLK-24FH HD-3 YBA-M22 HB-3
IRC-3 130082 3289A B 15 260001 SIF-24F HD-3 HS-22D HB-3
IRC-3 130082 3289A D 15 N/A SIF-24F HD-3 HS-22D HB-3
IRC-3 130082 3289A B 15 260001 SIF-24F HD-2 YBA-M22 HB-3
IRC-3 130082 3289A D 15 N/A SIF-24F HD-2 YBA-M22 HB-3
IRC-3 130082 3289A D 15 N/A SLK-24F HD-3 HS-22D HB-3
IRC-3 130082 3289A B 15 260001 SLK-24F HD-3 HS-22D HB-3
IRC-3 130082 3289A D 15 N/A SLK-24F HD-3 YBA-M22 HB-3
IRC-3 130082 3289A B 15 260001 SLK-24F HD-3 YBA-M22 HB-3
IRC-3 130082 3289A D 15 N/A SLK-24FH HD-3 HS-22D HB-3
IRC-3 130082 3289A B 15 260001 SLK-24FH HD-3 HS-22D HB-3
IRC-3 130082 3289A D 15 N/A SLK-24FH HD-3 YBA-M22 HB-3
IRC-3 130082 3289B B 15 260001 SLK-24FH HD-3 YBA-M22 HB-3
IRC-3 130108 3289B B 15 260001 SIF-24F HD-2 HS-22D HB-3
IRC-3 130108 3289B B 15 260001 SIF-24F HD-2 YBA-M22 HB-3
IRC-3 130108 3289B B 15 260001 SLK-24F HD-3 HS-22D HB-3
IRC-3 130108 3289B B 15 260001 SLK-24F HD-3 YBA-M22 HB-3
IRC-3 130108 3289B B 15 260001 SLK-24FH HD-3 HS-22D HB-3
IRC-3 130108 3289B B 15 260001 SLK-24FH HD-3 YBA-M22 HB-3
IRC-3 130108 3289B B 15 260001 SLK-24FH HD-3 YBA-M22 HB-3
IRC-3 240113 3289B B 15 260001 SIF-24F HD-2 HS-22D HB-3
IRC-3 240113 3289B B 15 260001 SIF-24F HD-2 YBA-M22 HB-3
IRC-3 240113 3289B B 15 260001 SLK-24F HD-3 HS-22D HB-3
IRC-3 240113 3289B B 15 260001 SLK-24F HD-3 YBA-M22 HB-3
IRC-3 240113 3289B B 15 260001 SLK-24FH HD-3 HS-22D HB-3
IRC-3 240113 3289B B 15 260001 SLK-24FH HD-3 YBA-M22 HB-3
IRC-3 240119 3289B B 15 260001 SIF-24F HD-2 HS-22D HB-3
IRC-3 240119 3289B B 15 260001 SIF-24F HD-2 YBA-M22 HB-3
IRC-3 240119 3289B B 15 260001 SLK-24F HD-3 HS-22D HB-3
IRC-3 240119 3289B B 15 260001 SLK-24F HD-3 YBA-M22 HB-3
IRC-3 240119 3289B B 15 260001 SLK-24FH HD-3 HS-22D HB-3
IRC-3 240119 3289B B 15 260001 SLK-24FH HD-3 YBA-M22 HB-3
IRC-3 240205 5389 B 15 PN260001 SIF-24F HD-2 HS-22D HB-3
IRC-3 240205 5389 B 15 PN260001 SIF-24F HD-2 YBA-M22 HB-3
IRC-3 240205 5389 B 15 PN260001 SLK-24F HD-3 HS-22D HB-3
IRC-3 240205 5389 B 15 PN260001 SLK-24F HD-3 YBA-M22 HB-3
IRC-3 240205 5389 B 15 PN260001 SLK-24FH HD-3 HS-22D HB-3
IRC-3 240205 5389 B 15 PN260001 SLK-24FH HD-3 YBA-M22 HB-3
LSS1, LSS4 4CLA 0.0 D 30 N/A SIF-24F HD-3 HS-220D HB-3
LSS1, LSS4 4CLA 0.0 D 30 N/A SIF-24F HD-3 HS-224D HB-5
LSS1, LSS4 4CLA 0.0 D 30 N/A SIF-24F HD-3 YBA-M224 HB-5
LSS1, LSS4 4CLA 0.0 D 30 N/A SIF-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24F HD-3 HS-220D HB-3
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24F HD-3 HS-M224 HB-5
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24F HD-3 YBA-M224D HB-5
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24FH HD-3 HS-220D HB-3
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24FH HD-3 HS-224D HB-5
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24FH HD-3 YBA-M224 HB-5
LSS1, LSS4 4CLA 0.0 D 30 N/A SLK-24FH HD-3 YBA-M220 HB-3
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-220D HB-3
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 HS-220D HB-3
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-224D HB-5
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 HS-224D HB-5
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M224 HB-5
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 YBA-M224 HB-5
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 HS-220D HB-3
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24F SLK-24F HS-220D HB-3
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24F SLK-24F HS-M224 HB-5
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 HS-M224 HB-5
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 YBA-M224D HB-5
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M224D HB-5
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 HS-220D HB-3
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-220D HB-3
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 HS-224D HB-5

Page 1 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-224D HB-5
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-M224 HB-5
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 HS-M224 HB-5
LSS1, LSS4 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 YBA-M220 HB-3
LSS1, LSS4 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 YBA-M220 HB-3
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-220D HB-3
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 HS-220D HB-3
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 HS-224D HB-5
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-224D HB-5
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 YBA-M224 HB-5
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M224 HB-5
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 HS-220D HB-3
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 HS-220D HB-3
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 HS-M224 HB-5
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 HS-M224 HB-5
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 YBA-M224D HB-5
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M224D HB-5
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M220 HB-3
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 HS-220D HB-3
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-220D HB-3
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 HS-224D HB-5
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-224D HB-5
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 YBA-M224 HB-5
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 YBA-M224 HB-5
LSS1, LSS4 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 YBA-M220 HB-3
LSS1, LSS4 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SIH-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SIH-24F HD-3 HS-224D HB-5
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SIH-24F HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SIH-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24F HD-3 HS-M224 HB-5
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24F HD-3 YBA-M224D HB-5
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24FH HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24FH HD-3 HS-224D HB-5
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24FH HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 4CLA 0.0 D 30 N/A SLK-24FH HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 HS-224D HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-224D HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SIH-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 HS-M224 HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24F HD-3 HS-M224 HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 YBA-M224D HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M224D HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-220D HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-224D HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 HS-224D HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 4ZEXP 0.0 B 30 3.9K OHM SLK-24FH HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 4ZEXP 0.0 D 30 N/A SLK-24FH HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 HS-224D HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 HS-224D HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SIH-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SIH-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 HS-220D HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 HS-M224 HB-5

Page 2 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 HS-M224 HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M224D HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 YBA-M224D HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24F HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 HS-220D HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-220D HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 HS-224D HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 HS-224D HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 YBA-M224 HB-5
LSS1/12,LSS4/12 MOTHERBOARD 0.0 D 30 N/A SLK-24FH HD-3 YBA-M220 HB-3
LSS1/12,LSS4/12 MOTHERBOARD 0.0 B 30 3.9K OHM SLK-24FH HD-3 YBA-M220 HB-3

Page 3 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

GRINNELL
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
C200 NA 24F B 30 7628 SIH-24F HD-3 HS-224D/HSB-224 HB-5
C200 NA 24F B 30 7628 SLK-24F,-FH HD3 HS-224D HB-5
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
AL-1500 AL-4ZDM HP-2A B 30 4.7K DCA-135 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K DCA-135 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K DCA-190 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K DCA-190 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K DFE-135 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K DFE-135 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K DFE-190 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K DFE-190 N/A YBF-RL/4H5US HB-21
AL-1500 AL-4ZDM HP-2A B 30 4.7K SIF-24F HD-2 HS-224RB HB-14
AL-1500 AL-4ZDM HP-2A B 30 4.7K SIH-24F HD-3 HS-224RB HB-14
AL-1500 AL-4ZDM HP-2A B 30 4.7K SLK-24F HD-3 HS-224RB HB-14
AL-1500 AL-4ZDM HP-2A B 30 4.7K SLK-24FH HD-3 HS-224RB HB-14
HCP1000 N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
HCP1000 N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
HCP1000 N/A A B, D 30 3.9K OHM DFE-135, -190 HD-3 HSC-220L HB-64
HCP1000 N/A A B, D 30 3.9K OHM DCD-135,DCD-190 HD-3 HSC-220R HB-72
HCP1000 N/A A B, D 30 3.9K OHM DCD-135,DCD-190 HD-3 NS4-220, NS6-220 HB-3
HCP1000 N/A A B, D 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
HCP1000 N/A A B, D 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
HCP1000 N/A A B, D 30 3.9K OHM SLR-24V HD-3 HSC-220R HB-72
HCP1000 N/A A B, D 30 3.9K OHM SLR-24V HD-3 NS4-220, NS6-220 HB-3
HCP1000 N/A A B, D 30 3.9K OHM SLR-835,-835H HD-5 HSC-220R HB-72
HCP1000 N/A A B, D 30 3.9K OHM SLR-835,-835W HD-5 NS4-220, -220W HB-3
HCP1000 N/A A B, D 30 3.9K OHM SLR-835,-835W HD-5 NS6-220, -220W HB-3
HCP1000 N/A A B, D 3 3.9K OHM SLR-835B-2 HD-6 N/A N/A
HCP1000 N/A A B, D 3 3.9K OHM SLR-835B-2W HD-6 N/A N/A
HCP1000 N/A A B, D 3 3.9K OHM SLR-835BH-2 HD-6 N/A N/A
HCP1000 N/A A B, D 3 3.9K OHM SLR-835BH-2W HD-6 N/A N/A
HCP1000 N/A A B, D 30 3.9K OHM SLR-835H,-835HW HD-5 NS4-220, -220W HB-3
HCP1000 N/A A B, D 30 3.9K OHM SLR-835H,-835HW HD-5 NS6-220, -220W HB-3
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SLR-835,-835W HD-5 SBC-2R HB-85
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SIJ-24 HD-3 SBC-2 HB-85
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SLR-24V HD-3 SBC-2 HB-85
HCP-1000 SERIES N/A A B, D 1 3.9K OHM SLR-24V HD-3 SBC-2R HB-85
HCP200 SERIES N/A A B, D 30 3.9K OHM DCD-135,DCD-190 HD-3 HSC-220R HB-72
HCP200 SERIES N/A A B, D 30 3.9K OHM DCD-135,DCD-190 HD-3 NS4-220, NS6-220 HB-3
HCP200 SERIES N/A A B, D 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
HCP200 SERIES N/A A B, D 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
HCP200 SERIES N/A A B, D 30 3.9K OHM DFE-135, -190 HD-3 HSC-220L HB-64
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-24V HD-3 HSC-220R HB-72
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-24V HD-3 NS4-220, NS6-220 HB-3
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-835,-835H HD-5 HSC-220R HB-72
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-835,-835W HD-5 NS4-220, -220W HB-3
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-835,-835W HD-5 NS6-220, -220W HB-3
HCP200 SERIES N/A A B, D 3 3.9K OHM SLR-835B-2 HD-6 N/A N/A
HCP200 SERIES N/A A B, D 3 3.9K OHM SLR-835B-2W HD-6 N/A N/A
HCP200 SERIES N/A A B, D 3 3.9K OHM SLR-835BH-2 HD-6 N/A N/A
HCP200 SERIES N/A A B, D 3 3.9K OHM SLR-835BH-2W HD-6 N/A N/A
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-835H,-835HW HD-5 NS4-220, -220W HB-3
HCP200 SERIES N/A A B, D 30 3.9K OHM SLR-835H,-835HW HD-5 NS6-220, -220W HB-3
HCP200 SERIES N/A A B, D 1 3.9K OHM SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
HCP200 SERIES N/A A B, D 1 3.9K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
HCP200 SERIES N/A A B, D 1 3.9K OHM SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
HCP200 SERIES N/A A B, D 1 3.9K OHM SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
HCP200 SERIES N/A A B, D 1 3.9K OHM SIJ-24 HD-3 SBC-2 HB-85
HCP200 SERIES N/A A B, D 1 3.9K OHM SLR-24V HD-3 SBC-2 HB-85
HCP200 SERIES N/A A B, D 1 3.9K OHM SLR-24V HD-3 SBC-2R HB-85

UPDATED 9/11/03
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

ISI WIRELESS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
FMS 1000 4ZID 4ZID D 66 N/A SIF-24F HD-2 HS-220 HB-3
FMS 1000 4ZID 4ZID D 66 N/A SLK-24FH HD-3 HS-220 HB-3
FMS 1000 4ZM 4ZMB B 66 4.7K OHM SIF-24F HD-2 HS-220 HB-3
FMS 1000 4ZM 4ZMA B 15 22K OHM SIF-24F HD-2 HS-220 HB-3
FMS 1000 4ZM 4ZMB B 66 4.7K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 1000 4ZM 4ZMA B 15 22K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500 4ZID 4ZID D 66 N/A SIF-24F HD-2 HS-220 HB-3
FMS 500 4ZID 4ZID D 66 N/A SLK-24FH HD-3 HS-220 HB-3
FMS 500 4ZM 4ZMA B 15 22K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500 4ZM 4ZMB B 66 4.7K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500 4ZM 4ZMA B 15 22K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500 4ZM 4ZMB B 66 4.7K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500-96 4ZID 4ZID D 66 N/A SIF-24F HD-2 HS-220 HB-3
FMS 500-96 4ZID 4ZID D 66 N/A SLK-24FH HD-3 HS-220 HB-3
FMS 500-96 4ZM 4ZMA B 15 22K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500-96 4ZM 4ZMB B 66 4.7K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500-96 4ZM 4ZMA B 15 22K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500-96 4ZM 4ZMB B 66 4.7K OHM SLK-24FH HD-3 HS-220 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

MIRCOM
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
FA-1000 N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-1000 N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-1000 N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-101U, FA-1020U N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-101U, FA-1020U N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-101U, FA-1020U N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-1025U N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-1025U N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM DFE-135, -190 N/A HSC-220L HB-64
FA-1025U N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-1025U N/A A B,D 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-1025U N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B,D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-104/8U N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-104/8U N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-104/BUX N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-104/BUX N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-104/BUX N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-200 N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-200 N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-200 N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-200 N/A A B, D 30 3.9K OHM SLR-835B-2 HD-6 N/A N/A
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-1000 N/A A B, D 30 3.9K OHM SLR-835B-2 HD-6 N/A N/A
SERIES 100 N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
SERIES 100 N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
SERIES 100 N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

MODULAR PROT.
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HS-2-RB HB-10
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HS-22D HB-3
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HSB-220 HB-56
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HSB-224 HB-53
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 YBA-M22 HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HS-2-RB HB-10
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HS-22D HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HSB-220 HB-56
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HSB-224 HB-53
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 YBA-M22 HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HS-2-RB HB-10
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HS-22D HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HSB-220 HB-56
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HSB-224 HB-53
RP-1002M A B, D 30 SLK-24FH HD-3 YBA-M22 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

NAPCO
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
GEM-3200,-P9600 NA GEM-PS B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P1632 NA MDL NO B 10 2.2K SLR-835B-2 HD-6 N/A N/A
GEM-P1632 NA NA B,D 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P3200 NA GEM-PF B 10 2.2K SLR-835B-2 HD-6 N/A N/A
GEM-P800 NA XP-S B 10 2.2K SLR-835B-2 HD-6 N/A N/A
GEM-P800,-P800E NA XP-S B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P800E,P801 NA XP-S B 10 3.9K OHM SLR-835B-2 HD-6 N/A N/A
GEM-P801 NA XP-S B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P816, V2,V3 GEM-P816 MDL NO B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P816, V2,V3 NA XP-S B 10 2.2K OHM SLR-835B-2 HD-6 N/A N/A
GEM-P9600 NA GEM-PS B 10 2.2K SLR-835B-2 HD-6 N/A N/A
MA3000,SS5500 NA MDL NO B 10 2.2K SLR-835B-2 HD-6 N/A N/A
MA3000/SS5500 NA MDL NO B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
SS-P3200 NA GEM-PS B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
SS-P3200,-P9600 NA GEM-PS B 10 2.2K SLR-835B-2 HD-6 N/A N/A
SS-P9600 NA GEM-PS B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
XP-400, XP-600 NA XP-S B 10 2.2K SLR-835B-2 HD-6 N/A N/A
XP400, XP600 NA XP-S B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

NOTIFIER
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
AFM-200 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFM-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AFM-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AFM-200 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AFM-200 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AFM-200 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AFM-200 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
AFP-200 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFP-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AFP-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AFP-200 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AFP-200 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AFP-200 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AFP-200 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
AM 2020 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AM 2020 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AM 2020 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AM 2020 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AM 2020 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AM 2020 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AM 2020 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
MMX-2 MMX-2 A BD 25 3.9K SIH-24F HD-3 HS-220 HB-56
MMX-2 MMX-2 A BD 25 3.9K SLK-24F/FH HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SIH-24F HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
RP-1001 N/A A BD 30 4.7K SLK-24F/FH HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SLK-24F/FH HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
RP-1002 N/A A BD 30 4.7K SIH-24F HD-3 HS-220 HB-56
RP-1002 N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
RP-1002 N/A A BD 30 4.7K SLK-24F/FH HD-3 HS-220 HB-56
RP-1002 N/A A B, D 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
S 5000 IZ-4,IZM-8 A B, D 15 4.7K OHM DFE-135,-190 N/A HSC-220L HB-64
S 5000 IZ-4,IZM-8 A B, D 15 4.7K OHM SLR-24H HD-3 HSC-220R HB-72
S 5000 IZ-4,IZM-8 A B, D 15 4.7K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
S 5000 IZ-4,IZM-8 A B, D 20 4.7K OHM SLR-835B-2 HD-6 N/A N/A
S 5000 IZM-8 A B, D 10 4.7K OHM DCD-135,-190 HD-3 HSC-220R HB-72
S 5000 IZM-8 A B, D 10 4.7K OHM DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
S 5000 IZM-8 A B, D 10 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
S 5000 IZM-8 A B, D 10 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
S 5000 IZM-8 A B, D 10 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
S 5000 IZM-8 A B, D 10 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24F HD-3 HS-22D HB-3

Page 1 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A A D 30 N/A HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24FH HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24FH HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 HS-220 HB-56
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24FH HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24FH HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24FH HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24FH HD-3 YBA-M220 HB-3
S 5000 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
S 5000 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
S 5000 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
S 5000 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
S 5000 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
S 5000 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
S 5000 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
SFB-400B N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SFB-400B N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
SFB-400 N/A A BD 30 4.7K SIH-24F HD-3 HSB-220 HB-56
SFB-400 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
SFB-400B N/A A B 30 4.7K SIH-24F HD-3 HS-2-RB HB-10
SFB-400B N/A A B 30 4.7K SIH-24F HD-3 HS-22D,YBA-M22 HB-3
SFB-400B N/A A BD 30 4.7K SIH-24F HD-3 HSB-220 HB-56
SFB-400B N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
SFB-400B N/A A B 30 4.7K SLK-24F/FH HD-3 HS-2-RB HB-10
SFB-400B N/A A B 30 4.7K SLK-24F/FH HD-3 HS-22D,YBA-M22 HB-3
SLG-2000 N/A A B, D 10 4.7K OHM DCD-135,-190 HD-3 HSC-220R HB-72
SLG-2000 N/A A B, D 10 4.7K OHM DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
SLG-2000 N/A A BD 30 4.7K SIH-24F HD-3 HSB-220 HB-56
SLG-2000 N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
SLG-2000 N/A A B, D 10 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
SLG-2000 N/A A B, D 10 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SLG-2000 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SLG-2000 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
SLG-2000 N/A A B, D 10 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
SLG-2000 N/A A B, D 10 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
SLG-2000,XPM-8 N/A A B, D 20 4.7K OHM SLR-835B-2 HD-6 N/A N/A
SLG-400 N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
SLG-400 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SLG-404 N/A A BD 30 4.7K SIH-24F HD-3 HSB-220 HB-56
SLG-404 N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
SLG-404 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SLG-404 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
SYSTEM 500 IZ-4 A B 35 4.7K SIH-24F HD-3 HSB-220 HB-56
SYSTEM 500 IZ-4 A B 35 4.7K SIH-24F HD-3 HSB-224 HB-53
SYSTEM 500 IZ-4 A B 35 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SYSTEM 500 IZ-4 A B 35 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
SYSTEM 500 IZ-4, IZM-8 A B, D 10 4.7K OHM DCD-135,-190 HD-3 HSC-220R HB-72
SYSTEM 500 IZ-4, IZM-8 A B, D 10 4.7K OHM DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
SYSTEM 500 IZ-4, IZM-8 A B, D 15 4.7K OHM DFE-135,-190 N/A HSC-220L HB-64
SYSTEM 500 IZ-4, IZM-8 A B, D 10 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
SYSTEM 500 IZ-4, IZM-8 A B, D 10 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SYSTEM 500 IZ-4, IZM-8 A B, D 10 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
SYSTEM 500 IZ-4, IZM-8 A B, D 10 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
SYSTEM 500 IZ-4, IZM-8 A B, D 15 4.7K OHM SLR-24H HD-3 HSC-220R HB-72
SYSTEM 500 IZ-4, IZM-8 A B, D 15 4.7K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
SYSTEM 500 IZ-4A A B 35 4.7K SIH-24F HD-3 HSB-220 HB-56
SYSTEM 500 IZ-4A A B 35 4.7K SIH-24F HD-3 HSB-224 HB-53
SYSTEM 500 IZ-4A A B 35 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SYSTEM 500 IZ-4A A B 35 4.7K SLK-24F/FH HD-3 HSB-224 HB-53

Page 2 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
SYSTEM 500 IZ-8 A BD 35 4.7K SIH-24F HD-3 HSB-220 HB-56
SYSTEM 500 IZ-8 A BD 35 4.7K SIH-24F HD-3 HSB-224 HB-53
SYSTEM 500 IZ-8 A BD 35 4.7K SLK-24/FH HD-3 HSB-224 HB-53
SYSTEM 500 IZ-8 A BD 35 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SYSTEM 500 IZE-A A BD 35 4.7K SIH-24F HD-3 HSB-220 HB-56
SYSTEM 500 IZE-A A BD 35 4.7K SIH-24F HD-3 HSB-224 HB-53
SYSTEM 500 IZE-A A BD 35 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SYSTEM 500 IZE-A A BD 35 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
SYSTEM 5000 IZE-A IZE-A B, D 35 4.7K SIH-24F HD-3 HSB-220 HB-56
SYSTEM 5000 IZM-8 IZM-8 B 35 4.7K SIH-24F HD-3 HSB-224 HB-53
SYSTEM 5000 IZE-A IZE-A B, D 35 4.7K SIH-24F HD-3 HSB-224 HB-53
SYSTEM 5000 IZE-A IZE-A B, D 35 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SYSTEM 5000 IZE-A A B, D 35 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
SYSTEM 5000 IZM-8 A B 35 4.7K SIH-24F HD-3 HSB-220 HB-56
SYSTEM 5000 IZM-8 A B 35 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
SYSTEM 5000 IZM-8 A B 35 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
XP TRANSPONDER N/A A B, D 20 2.2K OHM DCD-135,-190 HD-3 HSC-220R HB-72
XP TRANSPONDER N/A A B, D 20 2.2K OHM DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
XP TRANSPONDER N/A A B, D 20 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
XP TRANSPONDER N/A A B, D 20 2.2K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
XP TRANSPONDER N/A A B, D 20 2.2K OHM SLR-24 HD-3 HSC-220R HB-72
XP TRANSPONDER N/A A B, D 20 2.2K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
XP TRANSPONDER XPM-8 A B, D 60 4.7K SIH-24F HD-3 HSB-220 HB-56
XP TRANSPONDER XPM-8 A B, D 60 4.7K SIH-24F HD-3 HSB-224 HB-53
XP TRANSPONDER XPM-8 A B, D 60 4.7K SLK-24F/FH HD-3 HSB-220 HB-56
XP TRANSPONDER XPM-8 A B, D 60 4.7K SLK-24F/FH HD-3 HSB-224 HB-53

Page 3 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
PARADOX SECURITY SYSTEMS

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
SPECTRA 1738 N/A A B 1 N/A SLR-835BH-2 HD-6 N/A N/A
SPECTRA 1738 N/A A B 1 N/A SLR-835BH-2W HD-6 N/A N/A
SPECTRA 1738EX N/A A B 1 N/A SLR-835BH-2 HD-6 N/A N/A
SPECTRA 1738EX N/A A B 1 N/A SLR-835BH-2W HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

POTTER ELECTRIC
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
PFC-100 NRC N/A A B, D 25 5.1K SLK-24FH HD3 HS-221D HB4
PFC 100 RC N/A A B, D 1 5.1K SIH-24F HD-3 HS-221D HB-2
PFC 100 RC N/A A B, D 1 5.1K SIH-24F HD-3 HS-221D HB-4
PFC 100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HS-21D HB-2
PFC 100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HS-221 RB HB-13
PFC 100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HS-221D HB-4
PFC 100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HS-21D HB-2
PFC 100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HS-221 RB HB-13
PFC-100 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221 HB-54
PFC-100 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221N HB-54
PFC-100 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221R HB-71
PFC-100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221 HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221N HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221R HB-71
PFC-100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221 HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221N HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSC-221R HB-71
PFC-2000 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221 HB-54
PFC-2000 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221N HB-54
PFC-2000 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSC-221R HB-71
PFC-2000 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221 HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221N HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSC-221R HB-71
PFC-2000 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221 HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221N HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSC-221R HB-71
PFC-4410 N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221 HB-54
PFC-4410 N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221N HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221 HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221N HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221 HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221N HB-54
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

PROTECTOWIRE
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SIF-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SIF-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24FH HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24FH HD-3 HS-220D HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-135 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-190 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DFE-135,-190 N/A HSC-220L HB-64
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24H HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K SLR-24H HD-3 NS4-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-835B-2 HD-6 N/A N/A
FS2000 SERIES ZC-91 ZC-91 BD 30 4.7K OHM SIH-24F HD-S HS-220D HB-3
FS2000 SERIES ZC-91 ZC-91 BD 30 4.7K OHM SIH-24F HD-S HS-220D HB-3
FS2000 SERIES ZC-91 ZC-91 BD 30 4.7K OHM SLK-24F HD-3 HS-220D HB-3
FS2000 SERIES ZC-91M ZC-91 BD 30 4.7K OHM SLK-24F HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

RADIONICS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
D2012,D2112 2 WIRE POINT1 A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D2212 ZONE 1 221201 A 15 2K D262 HD-4 D261A HB-80
D2212, D2412 2 WIRE POINT1 A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D2212B 1 B A 15 15- D262 HD-4 D261A HB-80
D2212B ZONE 1 221201 A 15 2K D262 HD-4 D261A HB-80
D2212BE 1 B A 15 15- D262 HD-4 D261A HB-80
D2412UE 1 B A 15 15- D262 HD-4 D261A HB-80
D2812 1 B A 15 15 D262 HD-4 D261A HB-80
D2812,D2812U 2 WIRE POINT1 A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D4112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D4112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D4112 N/A 1 A 20 D104F SLK-12 HD-4 YBC-RL/12 HB-40
D6112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D6112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D6112 N/A 2 A 20 D104F SLK-12 HD-4 YBC-RL/12 HB-40
D7112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D7112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D7212 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D7212 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D7212 OWB/125B 24VDC MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7212 OWB/D125B 24VDC MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7212 OWB/D125B 24VDC MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5
D7212,D7412 D125B D125B A 40 1.8K OHM DFE-135,-190 N/A HSC-220L HB-64
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 HSC-220R HB-72
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-100, NS6-100 HB-55
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-224, NS6-224 HB-5
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 HSC-220R HB-72
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 NS4-220, NS6-220 HB-3
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 HSC-220R HB-72
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 NS4-220, NS6-220 HB-3
D7412 ONBOARD W/125B MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7412 ONBOARD W/D125B MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7412 ONBOARD W/D125B MDL NO A 15 1.8K SLK-12 HD-4 YBC-AL/12 HB-40
D7412 ONBOARD W/D125B MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5
D8112 D8112 W/D125B MDL NO A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D8112 D8112 W/D125B MDL NO A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D8112 N/A 2 TO 8 A 20 D108 SLK-12 HD-4 YBC-RL/12 HB-40
D8112,D9112 ZONE NO D125B A 40 1.8K OHM SLR-835B--2 HD-6 N/A N/A
D9112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D9112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 HSC-220R HB-72
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 NS4-220, NS6-220 HB-3
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 HSC-220R HB-72
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 NS4-220, NS6-220 HB-3
D9112B,D9124 D125B D125B A 40 1.8K OHM DFE-135,-190 N/A HSC-220L HB-64
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 HSC-220R HB-72
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-100, NS6-100 HB-55
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-224, NS6-224 HB-5
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-835B--2 HD-6 N/A N/A
D9412 D125B D125B A 40 1.8K OHM DFE-135,-190 N/A HSC-220L HB-64
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 HSC-220R HB-72
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-100, NS6-100 HB-55
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-224, NS6-224 HB-5
D9412 D125B D125B A 40 1.8K OHM SLR-835B--2 HD-6 N/A N/A
D9412 ONBOARD W/D125B MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D9412 ONBOARD W/D125B MDL NO A 15 1.8K SLK-12 HD-4 YBC-AL/12 HB-40
D9412 ONBOARD W/D125B MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5
D9412 ONBOARD W/D125B MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5

1 of 1
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

RAULAND-BORG
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
FA3002 FA3002 LP01 A 50 3.3K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP01 A 50 3.3K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP02 A 50 3.3K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP01 A 50 3.3K SIH-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP02 A 50 3.3K SIH-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP01 A 50 3.3K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP01 A 50 3.3K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP02 A 50 3.3K SLK-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP01 A 50 3.3K SLK-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP01 A 50 3.3K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3002 LP01 A 50 3.3K SLK-24FH HD-3 HSC-220R HB-72
FA3002 FA3002 LP02 A 50 3.3K SLK-24FH HD-3 HSC-220R HB-72
FA3002 FA3120,FA3125 CZ02 A 1 30K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ02 A 1 30K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ02 A 3 30K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ02 A 1 30K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ02 A 3 30K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ02 A 3 30K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FAP3125 CZ02 A 1 30K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ02 A 1 30K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ01 A 1 20K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ02 A 3 30K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ01 A 1 20K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ02 A 1 30K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ01 A 1 20K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ01 A 1 20K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ02 A 3 30K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ02 A 1 30K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ02 A 3 30K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ01 A 1 20K SLK-24FH HD-3 HSB-220 HB-56
FIRE PLEX FA3001 LPO1 2 A 50 1344 SIH-24F HD-3 HS-220D HB-3
FIRE PLEX FA3001 LPO1 2 A 50 1344 SLK-24F HD-3 HS-220D HB-3
FIRE PLEX FA3130,FAP3135 CZ01 A 1 1346 SLK-24F HD-3 HS-220D HB-3
FIRE PLEX FA3130,FAP3135 CZ01 A 1 1346 SIH-24F HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

SECURTON
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
MR-2600 MR-2600 MDL NO B 29 MRD-2904 SIH-24F HD-2 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 29 MRD-2904 SIH-24F HD-2 YBA-M221 HB-4
MR-2600 MR-2600 MDL NO B 25 MRD-2904 SIH-24F HD-3 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 25 MRD-2904 SIH-24F HD-3 YBA-M221 HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24F HD-3 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24F HD-3 YBA-M221 HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24FH HD-3 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24FH HD-3 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 34 MRD-2904 SIH-24F HD-2 HS-221D HB-4
MR-2900 MR-2928 A B, C 34 MRD-2904 SIH-24F HD-2 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 26 MRD-2904 SIH-24F HD-3 HS-221D HB-4
MR-2900 MR-2928 A B, C 26 MRD-2904 SIH-24F HD-3 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24F HD-3 HS-221D HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24F HD-3 HS-221D HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24F HD-3 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24FH HD-3 YBA-M221 HB-4
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

SILENT KNIGHT
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
5204 N/A 24C B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
5204 N/A 24C B 30 7628 SLR-24H HD-3 HSC-220R HB-72
5204 N/A 24C B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
5204 12 VOLT N/A N/A A 20 7628 SLK-24F HD-3 HS-224D HB-5
5204 12 VOLT N/A N/A A 20 7628 SLK-24FH HD-3 HS-224D HB-5
5207 5210 24A B 30 7628 DCD-135 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 DCD-190 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
5207 5210 24A B 30 7628 SIJ-24 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-24 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-24H HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-835 HD-3 NS4-100, NS6-100 HB-55
5207 5210 24A B 30 7628 SLR-835 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-835B-2 HD-6 N/A N/A
5207 5210 24A B 10 7628 SIH-24F HD-3 HS-224D/HSB-224 HB-5
5207 5210 24A B 10 7628 SLK-24F HD-3 HS-224D/HSB-224 HB-5
5207 N/A 24D B 30 7628 DCD-135 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 30 7628 DCD-190 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
5207 N/A 24D B 30 7628 SIJ-24 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24B A 40 7628 4.7 SLK-24F HD-3 HS-224D HB-5
5207 N/A 24A B 20 7628 SLK-24F HD-3 HS-224D HB-5
5207 N/A 24B A 40 7628 4.7 SLK-24FH HD-5 HS-224C HB-5
5207 N/A 24B A 40 7628 4.7 SLK-24FH HD-5 HS-224C HB-5
5207 N/A 24A B 20 7628 SLK-24FH HD-3 HS-224D HB-5
5207 N/A 24D B 30 7628 SLR-24 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 30 7628 SLR-24H HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 25 7628 SIH-24F HD-3 HS-224D/HSB-224 HB-5
5207 N/A 24D B 25 7628 SLK-24F HD-3 HS-224D/HSB-224 HB-5
5820, 5828XL N/A 24H B, D 12 7628 DCD-135,-190 HD-3 HSC-220L HB-64
5820, 5828XL N/A 24H B, D 12 7628 DCD-135,-190 HD-3 HSC-220R HB-72
5820, 5828XL N/A 24H B, D 12 7628 DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 DFE-135,-190 N/A HSC-220L HB-64
5820, 5828XL N/A 24H B, D 12 7628 SIJ-24 HD-3 HSC-220R HB-72
5820, 5828XL N/A 24H B, D 12 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 SLR-24H, -24V HD-3 HSC-220R HB-72
5820, 5828XL N/A 24H B, D 12 7628 SLR-24H, -24V HD-3 NS4-100, NS6-100 HB-55
5820, 5828XL N/A 24H B, D 12 7628 SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 SLR-835 HD-3 NS4-100, NS6-100 HB-55
5820, 5828XL N/A 24H B, D 12 7628 SLR-835 HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 SLR-835B-2 HD-6 N/A N/A
7181 N/A B B 30 7628 DCD-135 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 30 7628 DCD-190 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
7181 N/A B B 30 7628 SIJ-24 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1 HB-80
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1 HB-80
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1N HB-80
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1N HB-80
7181 N/A B B 30 7628 SLR-24 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 30 7628 SLR-24H HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
7181 N/A 24B B, D 20 7628 SLR-835B-2 HD-6 N/A N/A
SD500-SDM NA 241 B/D 25 7628 SIH-24F HD-3 YBA-M224 HB-5

Page 1 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
SD500-SDM NA 241 B, D 25 7628 SLK-24F HD-3 HS-224D HB-5
SD500-SDM NA 241 B, D 25 7628 SLK-24FH HD-3 HS-224D HB-5
SD500-SDM NA 241 B/D 25 7628 SLR-835B-2 HD-6 N/A N/A
SK-5208,FC-5208 SK-5217,FC-5217 24J B, D 15 7628 SLR-835H HD-5 HSC-220R HB-72
SK-5208,FC-5208 SK-5217,FC-5217 24J B, D 15 7628 SLR-835H HD-5 NS4-220,NS6-220 HB-3
SK-6324 N/A 24F B 15 N/A DCD-135,-190 HD-3 HSC-220L HB-64
SK-6324 N/A 24F B 15 N/A DCD-135,-190 HD-3 HSC-220R HB-72
SK-6324 N/A 24F B 15 N/A DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
SK-6324 N/A 24F B 15 N/A DFE-135,-190 HD-3 HSC-220L HB-64
SK-6324 N/A 24F B 15 N/A SIJ-24 HD-3 HSC-220R HB-72
SK-6324 N/A 24F B 15 N/A SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SK-6324 N/A 24F B 15 N/A SLR-24H, -24V HD-3 HSC-220R HB-72
SK-6324 N/A 24F B 15 N/A SLR-24H, -24V HD-3 NS4-100, NS6-100 HB-55
SK-6324 N/A 24F B 15 N/A SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
SK-6324 N/A 24F B 15 N/A SLR-835 HD-3 NS4-100, NS6-100 HB-55
SK-6324 N/A 24F B 15 N/A SLR-835 HD-3 NS4-220, NS6-220 HB-3
SK-6324 N/A 24F B 15 N/A SLR-835B-2 HD-6 N/A N/A
SK6324 N/A 24F D 10 7628 SLR-835H HD-5 HSC-220R HB-72
SK6324 N/A 24F D 10 7628 SLR-835H HD-5 NS4-220,NS6-220 HB-3
SK-6324 N/A 24F B 1 N/A SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
SK-6324 N/A 24F B 1 N/A SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
SK-6324 N/A 24F B 1 N/A SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
SK-6324 N/A 24F B 1 N/A SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
SK-6324 N/A 24F B 1 N/A SIJ-24 HD-3 SBC-2 HB-85
SK-6324 N/A 24F B 1 N/A SLR-24V HD-3 SBC-2 HB-85
SK-6324 N/A 24F B 1 N/A SLR-24V HD-3 SBC-2R HB-85
SK-2224 NA 24F B 30 7628 SIH-24F HD-3 HS-224D/HSB-224 HB-5
SK-2224 NA 24F B 30 7628 SLK-24F, -24FH HD-3 HS-224D HB-5
SK-2224, SK4224 N/A 24FF D 15 N/A DCD-135,-190 HD-3 HSC-220L HB-64
SK-2224, SK4224 N/A 24FF D 15 N/A DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24FF D 15 N/A DFE-135,-190 HD-3 HSC-220L HB-64
SK-2224, SK4224 N/A 24FF D 15 N/A SIJ-24 HD-3 HSC-220R HB-72
SK-2224, SK4224 N/A 24FF D 15 N/A SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24FF D 15 N/A SLR-24H, -24V HD-3 HSC-220R HB-72
SK-2224, SK4224 N/A 24FF D 15 N/A SLR-24H, -24V HD-3 NS4-100, NS6-100 HB-55
SK-2224, SK4224 N/A 24FF D 15 N/A SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24FF D 15 N/A SLR-835 HD-3 NS4-100, NS6-100 HB-55
SK-2224, SK4224 N/A 24FF D 15 N/A SLR-835 HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24FF D 15 N/A SLR-835B-2 HD-6 N/A N/A
SK2224, SK4224 N/A 24F B 10 7628 SLR-835BH-2 HD-6 N/A N/A
SK2224, SK4224 N/A 24F B 10 7628 SLR-835H HD-5 HSC-220R HB-72
SK2224, SK4224 N/A 24F B 10 7628 SLR-835H HD-5 NS4-100,NS6-100 HB-55
SK2224, SK4224 N/A 24F B 10 7628 SLR-835H HD-5 NS4-220 HB-3
SK-2224, SK4224 N/A 24F B 30 7628 DCD-135 HD-3 HSC-220R HB-72
SK-2224, SK4224 N/A 24F B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24F B 30 7628 DCD-190 HD-3 HSC-220R HB-72
SK-2224, SK4224 N/A 24F B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24F B 30 N/A DFE-135,-190 N/A HSC-220L HB-64
SK-2224, SK4224 N/A 24F B 30 N/A SIJ-24 HD-3 HSC-220R HB-72
SK-2224, SK4224 N/A 24F B 30 N/A SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24F B 30 7628 SLR-24 HD-3 HSC-220R HB-72
SK-2224, SK4224 N/A 24F B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24F B 30 N/A SLR-24H HD-3 HSC-220R HB-72
SK-2224, SK4224 N/A 24F B 30 N/A SLR-24H HD-3 NS4-220, NS6-220 HB-3
SK-2224, SK4224 N/A 24F B 1 7628 SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
SK-2224, SK4224 N/A 24F B 1 7628 SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
SK-2224, SK4224 N/A 24F B 1 7628 SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
SK-2224, SK4224 N/A 24F B 1 7628 SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
SK-2224, SK4224 N/A 24F B 1 7628 SIJ-24 HD-3 SBC-2 HB-85
SK-2224, SK4224 N/A 24F B 1 7628 SLR-24V HD-3 SBC-2 HB-85
SK-2224, SK4224 N/A 24F B 1 7628 SLR-24V HD-3 SBC-2R HB-85
SK4224 N/A 24FF D 10 7628 SLR-835H HD-5 HSC-220R HB-72
SK4224 N/A 24FF D 10 7628 SLR-835H HD-5 NS4-100,NS6-100 HB-55
SK4224 N/A 24FF D 10 7628 SLR-835H HD-5 NS4-220,NS6-220 HB-3
SK4224 N/A 24FF D 30 N/A SLR-835B-2 HD-6 N/A N/A
SK5208 N/A 24J B, D 15 7628 DCD-135,-190 HD-3 HSC-220L HB-64
SK5208 N/A 24J B, D 15 7628 DCD-135,-190 HD-3 HSC-220R HB-72
SK5208 N/A 24J B, D 15 7628 DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3

Page 2 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
SK5208 N/A 24J B, D 15 7628 DFE-135,-190 HD-3 HSC-220L HB-64
SK5208 N/A 24J B, D 15 7628 SIJ-24 HD-3 HSC-220R HB-72
SK5208 N/A 24J B, D 15 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SK5208 N/A 24J B, D 15 7628 SLR-24H, -24V HD-3 HSC-220R HB-72
SK5208 N/A 24J B, D 15 7628 SLR-24H, -24V HD-3 NS4-100, NS6-100 HB-55
SK5208 N/A 24J B, D 15 7628 SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
SK5208 N/A 24J B, D 15 7628 SLR-835 HD-3 NS4-100, NS6-100 HB-55
SK5208 N/A 24J B, D 15 7628 SLR-835 HD-3 NS4-220, NS6-220 HB-3
SK5208 N/A 24J B, D 15 7628 SLR-835B-2 HD-6 N/A N/A
SK5208/FC-5208 N/A 24J B, D 1 7628 SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
SK5208/FC-5208 N/A 24J B, D 1 7628 SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
SK5208/FC-5208 N/A 24J B, D 1 7628 SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
SK5208/FC-5208 N/A 24J B, D 1 7628 SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
SK5208/FC-5208 N/A 24J B, D 1 7628 SIJ-24 HD-3 SBC-2 HB-85
SK5208/FC-5208 N/A 24J B, D 1 7628 SLR-24V HD-3 SBC-2 HB-85
SK5208/FC-5208 N/A 24J B, D 1 7628 SLR-24V HD-3 SBC-2R HB-85
C6000 N/A 24E B 30 7628 DCD-135 HD-3 HSC-220R HB-72
C6000 N/A 24E B 30 7628 DCD-135 HD-3 HSC-221R HB-71
C6000 N/A 24E B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
C6000 N/A 24E B 30 7628 DCD-135 HD-3 NS4-221, NS6-221 HB-4
C6000 N/A 24E B 30 7628 DCD-135 HD-3 NS4-224, NS6-224 HB-5
C6000 N/A 24E B 30 7628 DCD-135 HD-3 NS6-11, NS4-100 HB-55
C6000 N/A 24E B 30 7628 DCD-190 HD-3 HSC-220R HB-72
C6000 N/A 24E B 30 7628 DCD-190 HD-3 HSC-221R HB-71
C6000 N/A 24E B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
C6000 N/A 24E B 30 7628 DCD-190 HD-3 NS4-221, NS6-221 HB-4
C6000 N/A 24E B 30 7628 DCD-190 HD-3 NS4-224, NS6-224 HB-5
C6000 N/A 24E B 30 7628 DCD-190 HD-3 NS6-11, NS4-100 HB-55
C6000 N/A 24E B 30 7628 SIJ-24 HD-3 HSC-220R HB-72
C6000 N/A 24E B 30 7628 SIJ-24 HD-3 HSC-221R HB-71
C6000 N/A 24E B 30 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
C6000 N/A 24E B 30 7628 SIJ-24 HD-3 NS4-221, NS6-221 HB-4
C6000 N/A 24E B 30 7628 SIJ-24 HD-3 NS4-224, NS6-224 HB-5
C6000 N/A 24E B 30 7628 SIJ-24 HD-3 NS6-11, NS4-100 HB-55
C6000 N/A 24E B 30 7628 SLR-24 HD-3 HSC-220R HB-72
C6000 N/A 24E B 30 7628 SLR-24 HD-3 HSC-221R HB-71
C6000 N/A 24E B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
C6000 N/A 24E B 30 7628 SLR-24 HD-3 NS4-221, NS6-221 HB-4
C6000 N/A 24E B 30 7628 SLR-24 HD-3 NS4-224, NS6-224 HB-5
C6000 N/A 24E B 30 7628 SLR-24 HD-3 NS6-11, NS4-100 HB-55

UPDATED 9/11/03

Page 3 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

SIMPLEX
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SIH-24F HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SIH-24F HD-3 HSB-221S HB-54
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24FB HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24FH HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24FH HD-3 HSB-221S HB-54
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24KB HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24KB HD-3 HSB-221S HB-54
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 40909101 SLK-24FB HD-3 HSB-221S HB-54
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

SPECTRONICS 2-Wire Compatibility Listings

PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
324 320/LC/OS-24 MDL NO B 15 15 K SIH-24F HD-2 HS-200 D HD-20
324 320/LC/OS-24 MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
324 320/LC/OS-24 MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
324 320/LC/OS-24 MDL NO B 13 15 K SLK-24FG HD-3 HS-200 D HD-20
624/641 MX8/WIB MDL NO B 13 15K SLK-24F HD-3 HS-200 D HD-20
624/MX ADS MDL NO B 15 15 K SIH-24F HD-2 HS-200 D HD-20
624/MX ADS MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
624/MX ADS MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
624/MX ADS MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
624/MX ADS-H MDL NO B 50 4.7K SIH-24F HD-2 HS-200 D HD-20
624/MX ADS-H MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
624/MX ADS-H MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/OSH MDL NO B 40 4.7K OHM SIF-24F HD-2 HS-22D HB-3
624/MX MX/OSH MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
624/MX MX/OSH MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 39 4.7K SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
624/MX MX/I0-1O MDL NO B, D 22 15 k SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/I01O-H MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/I01O MDL NO B 39 4.7K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/I01O MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/I01O MDL NO B, D 19 15 K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/I01O MDL NO B, D 22 15 K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/I01O-H MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/I01O-H MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/I0-1O-H MDL NO B 50 4.7K OHM SIH-24F HD-2 HS-22D HB-3
624/MX MX/I0-1O-H MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
624/MX MX/I0-1O-H MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
624/MX MX/OSRP MDL NO B 15 15 K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/OSRP MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/OSRP MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/OSRP MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640 MX8/WIBH MDL NO B 50 4.7K OHM SIF-24F HD-2 HS-22D HB-3
640 MX8/WIBH MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
640 MX8/WIBH MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
640 S2W MDL NO B 50 4.7K OHM SIF-24F HD-2 HS-22D HB-3
640 S2W MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
640 S2W MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
640 S2WA MDL NO D 50 N/A SIF-24F HD-2 HS-22D HB-3
640 S2WA MDL NO D 40 N/A SLK-24F HD-3 HS-22D HB-3
640 S2WA MDL NO D 40 N/A SLK-24FH HD-3 HS-22D HB-3
640/641 MX8/WIB MDL NO B 15 15 K SIF-24F HD-2 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2/OSS MDL NO B 15 15 K SIF-24F HD-2 HS-200 D HD-20
640/641 S2/OSS MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
640/641 S2/OSS MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
640/641 S21/OSS MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 15 15 K SIF-24F HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 11 15 K SIH-24F HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 13 15 K SLK-24F HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2W MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
640/641 S2W MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
640/641 S2W MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2WA MDL NO D 50 4.7K SIF-24F HD-2 HS-200 D HD-20
640/641 S2WA MDL NO D 39 4.7K SIH-24F HD-3 HS-200 D HD-20
640/641 S2WA MDL NO D 44 4.7K SLK-24F HD-3 HS-200 D HD-20
640/641 S2WA MDL NO D 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
641 MX8/WIBH MDL NO B 50 4.7K OHM SIF-24F HD-2 HS-22D HB-3
641 MX8/WIBH MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3

Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

2-Wire Compatibility Listings


PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
641 MX8/WIBH MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
641 S2W MDL NO B 50 4.7K OHM SIF-24F HD-2 HS-22D HB-3
641 S2W MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
641 S2W MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
641 S2WA MDL NO D 50 N/A SIF-24F HD-2 HS-22D HB-3
641 S2WA MDL NO D 40 N/A SLK-24F HD-3 HS-22D HB-3
641 S2WA MDL NO D 40 N/A SLK-24FH HD-3 HS-22D HB-3
FASA FASA FASA B 50 4.7K OHM SIF-24F HD-2 HB-22D HB-3
FASA FASA FASA D 50 N/A SIF-24F HD-2 HB-22D HB-3
FASA FASA MDL NO BD 50 4.7K SIF-24F HD-2 HS-200 D HD-20
FASA FASA MDL NO BD 39 4.7K SIF-24F HD-3 HS-200 D HD-20
FASA FASA FASA D 40 N/A SLK-24F HD-3 HB-22D HB-3
FASA FASA FASA B 40 4.7K OHM SLK-24F HD-3 HB-22D HB-3
FASA FASA MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
FASA FASA FASA B 40 4.7K OHM SLK-24FH HD-3 HB-22D HB-3
FASA FASA FASA D 40 N/A SLK-24FH HD-3 HB-22D HB-3
FASA FASA MDL NO BD 44 4.7K SLK-24FH HD-3 HS-200 D HD-20

Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

UPTIME
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
1A N/A ZA/B B 30 10K OHM SIF-24F HD-2 HS-21D HB-2
1A N/A ZA/B B 24 10K OHM SLK-24F HD-3 HS-21D HB-2
1A N/A ZA/B B 24 10K OHM SLK-24FH HD-3 HS-21D HB-2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

VIKING
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
PAR-3, B-1 N/A A BD 30 71252 SIH-24F HD-3 HSB-220 HB-56
PAR-3, B-1 N/A A BD 30 71252 SIH-24F HD-3 HSB-224 HB-54
PAR-3, B-1 N/A A BD 30 71252 SLK-24F HD-3 HSB-220 HB-56
PAR-3, B-1 N/A A BD 30 71252 SLK-24F HD-3 HSB-224 HB-54
PAR-3, B-1 N/A A BD 30 71252 SLK-24FH HD-3 HSB-220 HB-56
PAR-3, B-1 N/A A BD 30 71252 SLK-24FH HD-3 HSB-224 HB-54
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989

WORMALD
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
AUTOPULSE 1000 N/A SZB1 B 75 68710 SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 1000 N/A SZB1 B 75 68710 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 2000 N/A M6D1 D 45 N/A SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 2000 N/A M6B1 B 75 70061 SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 2000 N/A M6B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 3000 N/A M6D1 D 45 N/A SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 3000 N/A M6B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 3000 N/A M6B1 B 75 70061 SLK-24F HD-3 DI-201N HD-2
AUTOPULSE 4000 N/A M20D1 D 40 N/A SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 4000 N/A M20B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 4000 N/A M20B1 B 75 70061 SLK-24F HD-3 DI-201N HB-2
MULTIZONE 20M N/A M20D1 D 40 N/A SLK-24F HD-3 DB-201N HB-2
MULTIZONE 20M N/A M20B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
MULTIZONE 20M N/A M20B1 B 75 70061 SLK-24F HD-3 DI-201N HB-2
MULTIZONE 20P N/A M20B1 B 75 70061 SLK-24F HD-3 DB-201N HB-2
MULTIZONE 20P N/A M20D1 D 40 N/A SLK-24F HD-3 DB-201N HB-2
MULTIZONE 20P N/A M20B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
MULTIZONE 6P N/A M6D1 D 45 N/A SLK-24F HD-3 DB-201N HB-2
MULTIZONE 6P N/A M6B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
MULTIZONE 6P N/A M6B1 B 75 70061 SLK-24F HD-3 DI-201N HB-2
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7120-0410:0165 Page 1 of 1

CATEGORY: 7120 -- ANNUNCIATORS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model *FN-LCD-N Network LCD Annunciator and **Model FN-LCD-S Serial LCD Annunciator.
Connects to the control panel via the RS-485 network interface. Employs four Form C relays
that are unsupervised. **Up to 16 FN-LCD-S Serial LCD Annunciators can be connected to
one control panel. Refer to listee's data sheet for additional detailed product description and
operational considerations.

RATING: 24 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, rating, and UL label.

APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible Model FireNet
4127 fire alarm control unit (CSFM Listing No. 7165-0410:159). Refer to listee’s Installation
Instruction Manual for details.

NOTE:

*Recert 4-12-2007 jw

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7150-0410:0169 Page 1 of 1

CATEGORY: 7150 -- FIRE ALARM PULL BOXES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models DCP-AMS, DCP-AMS-LP, DCP-AMS-KL,


DCP-AMS-KL-LP,*FF0-PULL-SH,*FFO-PULL-SK,*FFO-PULL-DH, and *FFO-PULL-DK
addressable fire alarm manual pull boxes. “LP”,*"DH" and *"DK" suffixes are dual action
boxes. “KL”,*"SK", and *"DK" suffixes are key lock access boxes. Refer to listee's data
sheet for additional detailed product description and operational considerations.

RATING: 33 Vdc

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number and UL label.

APPROVAL: Listed as fire alarm manual pull boxes for use with separately listed electrically and
functionally compatible fire alarm control units.

These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and
California amendments except models with "LP" ,*"DH", and *"DK" suffixes.

*Rev 01-12-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 6911-0410:0175 Page 1 of 1

CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models FNV-MP and FNV-DP audio adjunct/voice evacuation systems. The FNV-MP is the
master panel in the system while the FNV-DP is the distributed panel. Each system is
modular in construction. Refer to listee's data sheet for additional detailed product
description and operational considerations. System components:

FNV-PWR2A: Power Supply


FNV-MFP: Master Fire Phone Card
FNV-DCC : Data Communication Control Card
FNV-ASC : Audio System Control Card
FNV-SSC : Switch Scan Card
FNV-MMC : Microphone Master Control Card
FNV-IOI : Input/Output Card
FNV-SLC : Switch and LED Card
FNV-MFH : Master Fire Phone Handset Card
FNV-MBR :Motherboard Card
FNV-AMI : Audio Module Interface Card
FNV-FPI : Motherboard/Relay Card
FNV-25E, -50E or -100E : Audio Adjunct Systems*

RATING: 120 VAC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as voice communication/evacuation/relocation/paging system for use with separately


listed electrically compatible fire alarm control unit. Suitable for high rise applications when
used in conjunction with separately listed electrically compatible high rise fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .

XLF: 6911-1446:0103

*Corrected 03-14-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 6911-0410:0176 Page 1 of 1

CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models EVAX 25, -25E, -50, -50E, -100, -100E, -150, -150E, -200, -200E audio adjunct
system. These units are intended to be used in conjunction with a listed electrically
compatible fire alarm control unit to provide voice communication, paging, evacuation tone
signals, and voice alarm signals with voice override. Refer to listee's data sheet for detailed
product description and operational considerations.

RATING: Input: 24-32 VAC/DC, Standby: 24 VDC, 7 Ah Battery

INSTALLATION: In accordance with listee's printed installation instructions, wiring diagram, applicable codes
and ordinances and in a manner which is acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as a voice/tone communication/evacuation/relocation/audio adjunct system for use


with separately listed electrically compatible fire alarm speakers and control units.
Supervision is dependent upon the fire alarm control panel. Refer to the control panel’s listing
and installation instructions for proper configurations. Suitable for high rise applications when
used in conjunction with separately listed fire alarm control units. Refer to listee’s Installation
Instruction Manual for details.

XLF: 6911-1446:0100

8-28-2008 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 6912-0410:0177 Page 1 of 1

CATEGORY: 6912 -- VOICE COMMUNICATION ACCESSORIES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model EVX-4Z and EVX-2ZA zone splitters. The unit is intended to be used in conjunction
with a listee's separtely listed Model EVAX-25 audio adjunct system (CSFM Listing No.
6911-0410:176). Refer to listee's data sheet for detailed product description and operational
considerations.

RATING: Input: 24-28 VDC

INSTALLATION: In accordance with listee's printed installation instructions, wiring diagram, applicable codes
and ordinances and in a manner which is acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating and UL label.

APPROVAL: Listed as a voice communication/audio adjunct system accessories.

XLF: 6912-1446:0101

8-28-2008 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0186 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models SCI-B4 and SCI-B6 Detector Isolator Bases. These models are to be used with
listee's Models ACA-V, ALG-V, ALK-V, AIE-EA, and ATG-EA detector heads. The Model
SCI-B6 is similar to Model SCI-B4 except for base size, 6 " base versus 4" base.

RATING: 17 - 41 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, rating, and UL label.

APPROVAL: Listed for use as detector bases with Manufacturer' s Models ACA-V, ALG-V, ALK-V,
AIE-EA, and ATG-EA detector heads. Refer to manufacturer's installation instruction and
manual for details.

Issued 7-11-11 mt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7305-0410:0200 Page 1 of 1

CATEGORY: 7305 -- MISCELLANEOUS SIGNALING EQUIPMENT

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: "Type NM" Signaling Stations, Model PB-SA yellow station with a momentary octagonal
button (push and release). Refer to listee's data sheet for detailed product description and
operational considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as a push button abort swtich. For indoor use only.

NOTE: Units are not acceptable for use as fire alarm pull stations.

XLF: 7305-1416:0103

06-20-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0201 Page 1 of 2

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model RAI-LED smoke-automatic fire detector accessory. Designed specifically for use with
listee’s:

Photoelectric Smoke Detectors


Model ALG-V (CSFM Listing No. 7272-0410:149),
Model ALK-V (CSFM Listing No. 7272-0410:173),
Model ACA-V (CSFM Listing No. 7272-0410:182),

Ionization Smoke Detector


Model AIE-EA (CSFM Listing No. 7271-0410:148)

Heat Detector
Model ATG-EA (CSFM Listing No. 7270-0410:147)

Bases
Model HSB-NSA-6 (CSFM Listing No. 7300-0410:132)
Model YBN-NSA-6 (CSFM Listing No. 7300-0410:132)
Model ASB (CSFM Listing No. 7300-0410:161)
Model SCI-B4 (CSFM Listing No. 7300-0410:186)
Model SCI-B6 (CSFM Listing No. 7300-0410:186)

FACP
Model FireNET (CSFM Listing No. 7165-0410:159)
Model FireNET Plus (CSFM Listing No. 7165-0410:180)

Refer to listee's data sheet for additional detailed product description and operational
considerations.

RATING: 7 mA

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as a smoke-automatic fire detector accessory for use with the compatible detector

04-05-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


Listing No. 7300-0410:0201
Page 2 of 2
heads, bases and Fire Alarm Control Panels [FACP] listed above to provide a remote visual
indication of an alarm condition. Refer to listee’s Installation Instruction Manual for details .

NOTE: The notification appliance is supplemental and is NOT intended as the primary evacuation
signal appliance.

04-05-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7259-0410:0202 Page 1 of 1

CATEGORY: 7259 -- SMOKE DETECTOR-AIR SAMPLING TYPE

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models VPR-1, VPR-4, VPR-6 , VPR-15 and VPR-1P air sampling, laser, aspirating smoke
detector. The detectors are intended to detect an abnormal amount of smoke density in the
area from which the detector is sampling and transmit this alarm signal to a fire alarm control
panel. The fan draws in air from which a small amount of air is passed in to the detector
chamber. The number of particles contained within the sampled air is measured using a
laser. Refer to listee's data sheet for additional detailed system description and operational
considerations.

RATING: 24 VDC

INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, other applicable codes
& ordinances, and in a manner acceptable to the authority having jurisdiction. Power supply
must provide the required 24 hour standby power.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as an air sampling smoke detector system for use with separately listed compatible
fire alarm control unit. Detectors must be used with a U.L. 1481 Listed power supply.
Authority having jurisdiction should be consulted prior to installation. Refer to listee’s
Installation Instruction Manual for details.

XLF: 7259-1728:0100

08-05-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7270-0410:0203 Page 1 of 1

CATEGORY: 7270 -- HEAT DETECTOR

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model ATJ-EA Analog Addressable Combination 15°F Rate of Rise / 135-194°F Fixed
Temperature Heat Detector for use with base Models HSB-NSA-6 or YBN-NSA-4. Refer to
listee's data sheet for additional detailed product description and operational considerations.

RATING: 17.0 - 40.7 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, electrical/temperature rating and UL label.

APPROVAL: Listed as heat detector for use with separately listed compatible fire alarm control units.
Refer to manufacturer’s Installation Manual for details .

08-19-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7272-0410:0204 Page 1 of 1

CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models ALN-V and ACC-V analog addressable photoelectric smoke detectors for use with
Models HSB-NSA-6 or YBN-NSA-4 bases.. Model ACC-V has a supplementary 135°F or
150°F heat detector. Refer to listee's data sheet for additional detailed product description
and operational considerations.

RATING: 17.0 - 39.5 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, electrical/temperature rating and UL label.

APPROVAL: Listed as an analog photoelectric smoke detector for use with listee’s separately listed
compatible fire alarm control units Models FireNet Plus (CSFM No. 7165-0410:0180) and
FireNet 4127 (CSFM No. 7165-0410:0159) . Refer to listee’s Installation Instruction Manual
for details.

NOTE: The photoelectric type detectors are generally more effective at detecting slow , smoldering
fires, which smolder for hours before bursting into flames. Sources of these fires may
include cigarettes burning in couches or bedding. The ionization type detectors are generally
more effective at detecting fast, flaming fires, which consume combustible materials rapidly
and spread quickly. Sources of these fires may include paper burning in a waste container
or a grease fire in the kitchen.

08-19-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7080-0410:0205 Page 1 of 1

CATEGORY: 7080 -- EXTINGUISHING SYSTEMS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models FNX-20S, FNX -40S, FNX -80S, FNX -100S, FNX -200S, FNX -500S, FNX -1200, FNX
-2000, FNX -3000, FNX -5700 Pre-Engineered Aerosol Generating Fire Extinguishing System
Units. Models FNX-MB-20S, FNX-MB 4080S1/ FNX-MB 4080S2, FNX-MB-125, FNX-MB
122030, FNX-MB 57 Bracket Assemblies. For Class A surface burning and Class B and C
category hazards; not for use in hazardous (classified) locations. Temperature range -54 to
54°C. Refer to listee's data sheet for detailed product description and operational
considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances,
NFPA 2010 and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name , model number and UL label.

APPROVAL: Listed as a Pre-Engineered Aerosol Generating Fire Extinguishing System.

XLF: 7080-2128:0100

09-04-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7165-0410:0206 Page 1 of 1

CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HCVR-3-R (115V), HCVR-3-R (230V), HCVR-3-C (115V) and HCVR-3-C (230V)
Conventional releasing fire alarm system. Local, manual and automatic, sprinkler
supervisory and waterflow services. Refer to listee's data sheet for additional detailed
product description and operational considerations.

RATING: 120V, 50 / 60Hz, 2.1A, and 240V, 50 / 60Hz, 1.1A

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, rating, and UL label.

APPROVAL: Listed as fire alarm control units for use with listed compatible indicating and initiating
devices.

NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.

XLF: 7165-1714:0116

09-04-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0207 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HCVR-SDU-6S-R, HCVR-SDU-6F-R, HCVR-SDU-6SM-R, HCVR-SDU-6FM-R,


HCVR-SDU-6S-C, HCVR-SDU-6F-C, HCVR-SDU-6SM-C, HCVR-SDU-6FM-C; Lamp status
units.
Models HCVR-ABE-R, HCVR-ABE-C; Ancillary boards w/enclosures.
Models HCVR-AS-R, HCVR-AS-C; Abort switches.
Model HCVR-SQA; Sequential activator.
*Models HCVR-DS-R, HCVR-DS-C; Manual Extinguishant Disablement Switches.

Refer to listee's data sheet for additional detailed product description and operational
considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, rating, and UL label.

APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .

XLF: 7300-1714:0117

*Rev 10-02-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0208 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HEPA, HEPB, HEPG and HEPR extender plates with color strobes. Models HEPAS,
HEPBS, HEPGS and HEPRS surface mounted extender plates with colored strobes. Refer
to listee's data sheet for additional detailed product description and operational
considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number and UL label.

APPROVAL: Listed as extender plates for wall mount indoor use with listee's separately listed speakers or
speaker/strobes (CSFM No. 7320-0410:0194 or 7320-0410:0195) only. Refer to
manufacturer’s installation manual for details.

XLF: 7300-0569:0147

01-15-14 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0210 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model ASBL low frequency 520 Hz addressable detector sounder base. Refer to listee's
data sheet for detailed product description and operational considerations.

RATING: 17-41 Vdc

INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as a low frequency addressable detector base for use with listee' s models ALG-V
(CSFM No. 7272-0410:0149), ALK-V and ALK-V2 (CSFM No. 7272-0410:0173), ACA-V
(CSFM No. 7272-0410:0182), AIE-EA (CSFM No. 7271-0410:0148), ATG-EA (CSFM No.
7270-0410:0147), ATJ-EA (CSFM No. 7270-0410:0203), ALN-V and ACC-V (CSFM No.
7272-0410:0204) detector heads. This unit can generate a low frequency alarm signal for
sleeping areas in accordance with NFPA 72. Refer to listee’s Installation Instructions Manual
for details.

12-10-14 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 3240-0410:0155 Page 1 of 1

CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models DH-98-I, DH-98-P, DH-98-A, DH-98-ARSK, DH-98-ASK, DH-98-AR, DH-98-HVI,


DH-98-HVP, *DH-99-A with ALK-D in duct housing, *DH-99-AR with ALK-D in duct housing,
FFO-DUCT* with FFO-DH in duct housing and FFO-DUCTR * with FFO-DH in duct housing
duct smoke detector units. Each unit consists of a smoke detector head, Models SIJ-24DH
(ionization type), SLR-24DH, ALG-DH, or ALG-EA (photoelectric type), plastic enclosure,
plastic cover, relays, electrical components, and sampling and exhaust tubes. The smoke
detector heads are not suitable for use as open area detection. Refer to listee's data sheet
for additional, detailed product description and operational considerations. For use with the
following accessories: MS-RA, MS-RA/P, MS-RA/R, MS-RA/P/R, MS-KA/R, MS-KA/P/R,
SD505-DTS-K, and MS-RH/KA/P/R remote alarms.

RATING: 120 VAC, 230 VAC, 24 VAC and 24 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, electrical rating and UL label.

APPROVAL: Listed as duct smoke detector units for use with separately listed compatible fire alarm
control units to detect an abnormal amount of smoke density in the return air ducts of air
conditioning and ventilating system. The air velocity in the duct shall be between 300-4000
fpm.

NOTE: For duct application only. Not suitable for open area protection.

*Rev 09-05-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 3242-0410:0179 Page 1 of 1

CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE)

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model ALK-D duct smoke detector, analog, addressable photoelectric type sensor. Refer to
listee's data sheet for additional detailed product description and operational considerations.

INSTALLATION: The unit is intended to be installed to and mounted in air ducts with airflows up to 4000
ft/min. In accordance with listee's printed installation instructions and applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as photoelectric type, duct smoke detectors for use with separately listed compatible
fire alarm control unit, Hochiki Model FireNet 4127 (CSFM Listing No. 7165-0410:159). The
unit is for use with listed compatible bases, Hochiki Model YBN-NSA-4 or HSB-NSA-6
(CSFM Listing No. 7300-0410:132). Suitable for use in ducts with airflows up to 4000 ft/min.
Refer to listee’s Installation Instruction Manual for details .

12-16-2009 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7120-0410:0153 Page 1 of 1

CATEGORY: 7120 -- ANNUNCIATORS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model HRAM-208 remote multiplex annunciator and HRTI-1 Remote trouble Indicator. Refer
to listee's data sheet for additional detailed product description and operational
considerations.

RATING: 20-19 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. For indoor use only.

MARKING: Listee's name, model number and UL label.

APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible Model HCP-200
Series fire alarm control unit (CSFM Listing No. 7165-0410:152).

XLF: 7120-1477:0108

*Rev 11-16-2000

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7120-0410:0157 Page 1 of 1

CATEGORY: 7120 -- ANNUNCIATORS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model HRA-1000 remote multiplex annunciator panel. The main annunciator module provides
indication for 32 zones. Each adder annunciator module provides indication for 48 additional
zones. Unit includes main annunciator chassis HRAM-1032 and adder annunciator chassis
HRAX-1048. Refer to listee's data sheet for additional detailed product description and
operational considerations.

RATING: 20-29 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. For indoor use only.

MARKING: Listee's name, model number and UL label.

APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible Model
HPC-1000 fire alarm control unit (CSFM Listing No. 7165-0410:154).

XLF: 7120-1477:0107

*Rev 11-16-2000

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7120-0410:0181 Page 1 of 1

CATEGORY: 7120 -- ANNUNCIATORS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model FNP-LED Graphix LED eMatrix Mimic Display, where X can be the number 1 or 2
denotes color of the enclosure, and -YYY denotes the number of LED extension boards
which could be 1, 3 or 5 boards.

Refer to listee's data sheet for additional detailed product description and operational
considerations.

RATING: 24 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, product number, electrical rating and UL label.

APPROVAL: Listed as annunciators for use with listee’s separately listed compatible fire alarm control
units. Refer to manufacturer’s Installation Manual for details .

03-01-10 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7125-0410:0192 Page 1 of 1

CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model HES3-12WR, HES3-12WW, HES3-12PWR and HES3-12PWW strobe lights. Refer to
listee's data sheet for additional detailed product description and operational considerations

RATING: Candela: Selectable 15cd, 30cd, 60cd, 75cd


Electrical: 8-17.5 V dc (NOTE: this unit only runs on filtered DC voltage, not on
FWR voltage)

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed
compatible fire alarm control units. Refer to listee’s Installation Instruction Manual for details .

XLF: 7125-0569:0129

08-08-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7135-0410:0190 Page 1 of 1

CATEGORY: 7135 -- AUDIBLE DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model HX91-R, HX91-W, HX93-R and HX93-W horns. Model HX-93 has selectable continuous
or temporal tones. Refer to listee's data sheet for additional product description and
operational considerations.

RATING: Electrical: 8-33 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as horns for use with separately listed compatible fire alarm control units. For indoor
use only.

Unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal
(for total evacuation).

XLF: 7135-0569:0126

08-05-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7135-0410:0193 Page 1 of 1

CATEGORY: 7135 -- AUDIBLE DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HEC3-12 WR, HEC3-12WW, HEC3-12PWR and HEC3-12PWW multi-candela


horn/strobes. Model HEC3-12 horn/strobe is wall mounted and for indoor use. Refer to
listee's data sheet for additional product description and operational considerations.

RATING: Electrical: 8-17.5 Vdc, 7-55 mA


Candela: 15cd, 30cd, 60cd, 75cd

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as horn and horn/strobes for use with separately listed compatible fire alarm control
units. For indoor use only. Refer to listee’s Installation Instruction Manual for details .

XLF: 7135-0569:0130

08-08-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7150-0410:0162 Page 1 of 1

CATEGORY: 7150 -- FIRE ALARM PULL BOXES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HPS-SAH, HPS/SAK, HPS-DAH, HPS-DAH/S, and HPS-SAH-WP with or without
the suffix DA-C non-coded manual pull stations. Refer to listee's data sheet for detailed
product description and operational considerations.

INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm
control units. Model HPS-SAH-WP is suitable for outdoor use. Refer to listee’s Installation
Instruction Manual for details.

* These manual pull boxes do not meet the requirements of UL Standard 38, 1999 Edition
and California amendments.

XLF: 7150-1039:0101

*Updated 6-22-2009 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7150-0410:0164 Page 1 of 1

CATEGORY: 7150 -- FIRE ALARM PULL BOXES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HPS-CP and HPS/CP/S non-coded boxes. Refer to listee's data sheet for detailed
product description and operational considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model name, and UL label.

APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .

* These manual pull boxes do not meet the requirements of UL Standard 38, 1999 Edition
and California amendments.

XLF: 7150-0512:0006

*Updated 6-22-2009 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7151-0410:0163 Page 1 of 1

CATEGORY: 7151 -- BOXES/PULL STATIONS-HAZARDOUS LOCATIONS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model HPS-SA-EX/WP with or without the suffix DA-C non-coded, explosion proof, weather
proof manual pull stations. These devices consist of a switch and terminal block mounted
within an explosion proof enclosure. Refer to listee's data sheet for additional detailed
product description and operational considerations.

RATING: Electrical: 120 VAC, 10 A

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances,
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm
control units. Suitable for use outdoor and in Class I, Group B, C and D; Class II, Group E, F
and G hazardous locations. Refer to listee’s Installation Instruction Manual for details .

*These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with
California amendments except for models with suffixes -DAH.

XLF: 7151-1039:0104

*Updated 08-27-2009 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7165-0410:0154 Page 1 of 1

CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: HCP-1000 fire alarm control unit. Non-coded, automatic, manual, local, auxiliary, remote
station, waterflow and sprinkler supervisory service. System components:

HCP-1000 Control Unit


HBB-1024, HBB-1072 Backbox
HMCC-1024-6, -12 24-Zone Chassis
HMCC-1024-6S, -12S 24-Zone Chassis
HECH-1048 Expander Chassis
HDM-1008 8-Zone Detection Module
HSGM-1004 4-Zone NAC Module
HRM-1008 Relay Adder Module
HPR-100 Polarity Reversal and City Tie
HFA-1024TR Flush Trim Ring

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating and UL label.

APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally
compatible initiating and indicating devices.

This control unit can generate a distinctive three- pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to
listee's Installation Manual for details.

This control unit meets the requirement of UL-864, 8th Edition Standard.

NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.

XLF: 7165-1477:0106

*Rev 11-16-2000

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7165-0410:0159 Page 1 of 2

CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model FireNet 4127 Analog Addressable fire alarm control unit. Automatic, manual, waterflow
and sprinkler supervisory service. Refer to the listee's data sheet for detailed product
description and operational considerations. System components:

MODULE PART NO. DESCRIPTION


FN-4127-BO (K6002) Control Board
FN-4127-IO (K6006) 16 Channel Input/Output Board
FN-4127-CPA-BO (K6001) Front LCD Indicator Panel
FN-4127-SLC (K6004) Loop 3, 4 Board
FN-4127-NIC (K6005) Network Card
FN-PS402 (S402) Power Supply
FN-DAC (FN-DAC) Digital Alarm Communicator
FN-ENC (FN-ENC) Enclosures
FN-ACC (FN-ACC) Battery/Accessory Enclosure
FN-CTM (7000-00780) City Tie Module
D9068 (D9068) Bosch Digital Alarm Communication
Transmitter
HMX-DP Voice Evacuation System Distribution Panel
HMX-MP Voice Evacuation System Master Panel
EVX-100 Audio Adjunct Module
EVX-RM Remote Microphone

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and
indicating devices. *Also suitable for high-rise applications.

These control units can generate the distinctive three- pulse Temporal Pattern Fire Alarm
Evacuation Signal as required per NFPA 72, 2002 Edition.

This control unit meets the requirements of UL-864, *9th Edition Standard

NOTE: 1. For Fire Alarm Verification Feature (Delay of fire alarm), the maximum

*Rev 6-24-2009 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


Listing No. 7165-0410:0159
Page 2 of 2
Retard/Reset/Restart period must be adjusted to 30 seconds or less.

2. Combined with 7170-0410:170

*Rev 6-24-2009 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7165-0410:0180 Page 1 of 1

CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models FIRENET PLUS 1127 Series. Analog Addressable Fire Alarm System. May be
followed by suffixes -R or -C which represents the color of the panel enclosure, -R for red, -C
for charcoal. Non-coded, automatic, manual, local, remote station, central station is with
(DACT), waterflow and sprinkler supervisory service. Refer to listee's data sheet for
additional detailed product description and operational considerations. System components:

FNP-1127-R; Loop Not Expandable, Red


FNP-1127-C; Loop Not Expandable, Charcoal
FNP-1127D-R; Loop W/Integrated Dialer, Not Expandable, Red
FNP-1127D-C; Loop W/Integrated Dialer, Not Expandable, Charcoal
FNP-1127E-R; Loop Expandable, Red
FNP-1127E-C; Loop Expandable, Charcoal
FNP-1127DE-R; Loop W/Integrated Dialer, Expandable, Red
FNP-1127DE-C; Loop W/Integrated Dialer, Expandable, Charcoal
FNP-1127-SLC; Loop Expansion Module*

RATING: 120V, 50 / 60Hz, 2.1A, and 240V, 50 / 60Hz, 1.1A

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, rating, and UL label.

APPROVAL: Listed as fire alarm control units for use with listed compatible indicating and initiating devices.
Also suitable for high rise applications.

These control units generate a distinctive temporal pattern (Temporal Pattern Fire Alarm
Evacuation) for total evacuation in accordance with NFPA 72, 2002 Edition. This control unit
meets the requirements of UL Standard 864, 9th Edition.

NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.

XLF: 7165-1714:0115

*Rev. 11/26/14 jp

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7165-0410:0183 Page 1 of 1

CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HCA-2, HCA-4, HCA-8 fire alarm control units. *"D" suffix to models adds
off-premises signaling utilizing a DACT. Non-coded; automatic, manual, local, remote
station, central station, waterflow and sprinkler supervisory service. System components:

HCA-2, -4, -8; Main Fire Alarm Assembly


P/N 06.005, 06.006; End of Line Resistor
P/N 06.007; End of Line Monitor
MBC; Mini Battery Cabinet
HCA-RA; Remote Annunciator
131-035; Actuator
0300-1000; Abort Switch

RATING: 120/240VAC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating and ETL label.

APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally
compatible initiating and indicating devices.

NOTE: For Fire Alarm Verification Feature, the maximum Retard/Reset/Restart period shall not
exceed 30.0 seconds.

*Rev 03-29-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7270-0410:0178 Page 1 of 1

CATEGORY: 7270 -- HEAT DETECTOR

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models DSC-EA Rate-of-rise heat detector. Refer to listee's data sheet for detailed product
description and operational considerations.

RATING: 24 VDC

INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating and UL label.

APPROVAL: Listed as heat detector when used in conjunction with listed compatible HSB-100 base
(CSFM Listing No. 7300-0410:132) and separately listed compatible control units.

12-15-2009 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7260-0410:0158 Page 1 of 1

CATEGORY: 7260 -- SMOKE DETECTION SYSTEM-BEAM TYPE

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model SRA-24 projected beam smoke detector. Unit consists of a transmitter/receiver unit
and a reflector unit. This device is intended for ceiling installation only between 25 to 100 ft
apart. Refer to the listee's data sheet for detailed product description and operational
considerations.

RATING: 24 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction

MARKING: Listee's name, model number, electrical ratings, and UL Label.

APPROVAL: Listed as beam smoke detector for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instructions Manual for details .

4-14-03 KK

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7260-0410:0172 Page 1 of 1

CATEGORY: 7260 -- SMOKE DETECTION SYSTEM-BEAM TYPE

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model SPC-24 Projected Beam, Smoke-Automatic Fire Detector. Unit consists of one
emitter unit and one receiver unit. Refer to listee's printed data sheet for additional product
description and operational consideration.

RATING: 24 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings, and UL Label

APPROVAL: Listed as beam smoke detectors for use with separately listed compatible fire alarm control
units.

NOTE:

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7270-0410:0119 Page 1 of 1

CATEGORY: 7270 -- HEAT DETECTOR

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models AL-DFE-135 and AL-DFE-190. Refer to listee's data sheet for detailed product
description and operational considerations.

INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, temperature & electrical ratings and UL label.

APPROVAL: Listed as system heat detectors when used in conjunction with listed compatible bases
(CSFM Listing No. 7300-0410:132) and separately listed compatible control units.

*Rev 11-16-2000

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7270-0410:0147 Page 1 of 1

CATEGORY: 7270 -- HEAT DETECTOR

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models ATG - EA and FFO-HEATelectronic fixed temperature heat detector (analog) with
Models YBN-NSA-4, HSB-NSA-6, FFO-4BASE or FFO-6BASE bases. Unit consists of
resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring
board inside an enclosure. Refer to listee's data sheet for additional detailed product
description and operational considerations.

RATING: Electrical: 39.5 VDC


Temperature Range: 134°F - 149°F

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, electrical/temperature rating and UL label.

APPROVAL: Listed as heat detector for use with separately listed compatible fire alarm control units.

Rev 08-13-13 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7270-0410:0151 Page 1 of 1

CATEGORY: 7270 -- HEAT DETECTOR

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models DCD-135 and DCD-190, fixed temperature and rate of rise heat detectors. Refer to
listee's data sheet for additional detailed product description and operational considerations.

RATING: Temperature: DCD-135: 135 F


DCD-190: 190 F

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, rating and UL label.

APPROVAL: Listed as fixed temperature and rate of rise heat detector for use listed bases (CSFM Listing
No. 7300-0410:132) and separately listed fire alarm control units.

*Rev 11-16-2000

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7272-0410:0107 Page 1 of 1

CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models SLG-12, SLG-24, SLG-24FH, SLG-24F, SLK-12, SLK-24F, SLK-24FH, SLK-24FB,
SLK-24FL, SLK-24FLB, SLK-835, SLK-835H, SLR-835, SLR-835W, SLR-835B-2,
SLR-835B-4, SLR-835B-2W, SLR-835B-4W, SLR-24, SLR-24H, SLR-24V, *SLR-24VN,
SLR-835H, SLR-835HW, SLR-835BH-2, SLR-835BH-2W, SLR-835BH-4, SLR-835BH-4W
photoelectric type smoke detectors. Unit with suffix -H or -FH employs a supplemental heat
sensor. Refer to listee's data sheet for additional detailed product description and operational
considerations.

RATING: 12 VDC and 24 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, electrical rating and UL label.

APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm
control units when used in conjunction with listee's listed bases (CSFM Listing No.
7300-0410:132). Models with supplemental heat sensor are not approved for use in lieu of
required heat detectors.

NOTE: Formerly 7257-0410:107

*Rev 2-14-2003 IPI

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7272-0410:0149 Page 1 of 1

CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models ALG-EA and ALG-V analog addressable photoelectric type smoke detector with
Models YBN-NSA-4 and HSB-NSA-6 bases. Unit consists of resistors, capacitors, diodes,
transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer
to listee's data sheet for additional detailed product description and operational
considerations.

RATING: 39.5 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, electrical rating and UL label.

APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm
control units. *Model ALG-V is suitable for in duct use in air velocities up to 4000 ft/min.

NOTE:

*Rev 1-31-2008 mt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7272-0410:0173 Page 1 of 1

CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models ALK-V, ALK-V2,*FFO-SMOKE analog addressable photoelectric type smoke


detector with listed compatible bases, Hochiki Model YBN-NSA-4, HSB-NSA-6,
*FFO-4BASE or *FFO-6BASE (CSFM Listing No. 7300-0410:0132). Unit consists of
resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring
board inside an enclosure. Refer to listee’s data sheet for additional detailed product
description and operational considerations.

RATING: 39.5 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, electrical rating and UL label.

APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm
control units. Also suitable for in-duct use in air velocities up to 4000 ft/min. Refer to listee’s
Installation Instruction Manual for details.

*Rev 01-12-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7272-0410:0174 Page 1 of 1

CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models SLV-24, SLV-24V, SLV-24N and SLV-24M* Conventional, Photoelectric Type Smoke
Detectors. Detectors are for use with listed Models NS4-220, NS4-224, NS6-220, NS6-224,
HSC-4R, HSC-220R, and HSC-224R Bases. Refer to listee's data sheet for detailed product
description and operational considerations.

RATING: 24 Vdc

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, rating and UL label.

APPROVAL: Listed as photoelectric smoke detectors for use with listed bases as shown in “DESIGN” and
compatible listed fire alarm control units.

3-19-2008

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7272-0410:0182 Page 1 of 1

CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model ACA-V multi-sensor (photoelectric/heat) type detector. This model employs a 135°F
-150°F integral heat sensor. A fire alarm condition may be generated by the presence of
smoke or heat. Sensor may operate in a single (heat or photoelectric) or multi mode (heat &
photoelectric). Refer to listee's data sheet for additional detailed product description and
operational considerations.

RATING: 24 - 41 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, product number, electrical rating and UL label.

APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible
base and fire alarm control units. Also acceptable for duct application with air velocities from
0-4000 ft/min. Listed as heat type detector for use with listee's separately listed compatible
base and fire alarm control units. Listed temperature range for the heat portion is 135°F -
150°F. Refer in Manufacturer's Installation Instruction Manual for details.

08-12-10 fm

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0132 Page 1 of 2

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Detector bases (2 and 4-wire). Unit is intended for use with a separately listed compatible
detector head. Refer to listee's data sheet for detailed product description and operational
considerations. Models listed below.

HA-4W HA-4W1 HA-4WX HA-2


HA-SL HA-SR HA-SLR HA-RA2
HA-NRA2 HA-L12R HA-2R HA-22R
HA-L2 HA-L2A HA-L2R HA-L22
HA-L22A HA-L22F HA-L22R HA-L22S
HA-LA2 HA-LRA HA-LRA2 HA-LNA2
HA-LNRA2

HS-2 HS-2L HS-2D HS-21


HS-21L HS-21D HS-22 HS-22L
HS-22D HS-100 HS-200D HS-220
HS-220L HS-220D HS-221 HS-221L
HS-221D HS-221X HS-221XL HS-221XD
HS-224 HS-224L HS-224D HS-225
HS-225L HS-225D HS-2RB HS-21RB
HS-220RB HS-221RB HS-224RB HS-2RB4

HSB-2 HSB-2N HSB-12-1 HSB-12-1N


HSB-12-4 HSB-12-4N HSB-21 HSB-21N
HSB-100 HSB-200 HSB-200N HSB-220
HSB-220N HSB-221 HSB-221N HSB-221S
HSB-224 HSB-224N HSB-225 HSB-225N
HSC-4R HSC-21L HSC-220L HSC-220R
HSC-221L HSC-221R HSC-224RA HSC-224L
HSC-224R HSC-225L HSB-DCP-6 HSB-NSA-6

YBA-M2 YBA-M21 YBA-M22 YBA-M220


YBA-M221 YBA-M224 YBA-M225 YBA-M100
YBA-MAP YBA-R3 YBA-RL/4 YBA-RL/4-1
YBA-RL/4-2 YBA-RL/4-RA YBC-RL/12 YBC-RL/12-1

*Rev 01-12-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


Listing No. 7300-0410:0132
Page 2 of 2
YBC-RL/12-2 YBC-RL/12-4 YBC-RL/4-RA YBC-RL/2NC
YBC-RL/2NBE YBJ-RL/2ND YBN-R/2NA YBN-NSA-4
NS4-100 NS4-220 NS4-221 NS4-224
NS6-100 NS6-220 NS6-221 NS6-224
*FFO-4BASE *FFO-6BASE *FFO-SBASE
Models may or may not come with suffix -W.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating and UL label.

APPROVAL: Listed as bases for use with listee’s separately listed compatible smoke and heat detectors .
Refer to heat or smoke detector listings for compatibility. Models HA-2R, HA-SLR, HA-LRA2
and HSC Series w/ suffix R are also suitable for releasing device service . Model YBA-R3 is
intended for use with thermostat detector only.

NOTE: Formerly 7300-0410:100, 106, 115, 124, 125, 126, 130, 131 & 133

*Rev 01-12-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0150 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Control Unit Accessories Models:

DCP-RM, DCP-R2M, *FFO-2RM; Analog Relay Module


DCP-SCI,*FFO-SCIM; Short Circuit Isolator
DCP-FRCME, DCP-FRCME-M, DCP-FRCME-P,*FFO-MMP; Monitor Modules
DCP-FRCME-S, DCP-FRCME-4,*FFO-MM4; Monitor Modules
DCP-FRCME-S-100, DCP-FRCME-4-100; Monitor Modules
DCP-SOM,*FFO-OM; Supervised Output Module
DCP-SRM; Solenoid Releasing Module
DCP-DIMM,*FFO-2MM; Dual Input Monitor Module
DCP-CZM,*FFO-ZM; Conventional Zone Module
DCP-SOM-A; Supervised Output Module
DCP-SOM-R; Supervised Output Module Release
DCP-SOM-AI; Supervised Output Module with Integrated SCI
DCP-FRCMA; Input Module Box Mount
DCP-FRCMA-I; Input Module Box Mount with Integrated SCI
DCP-R2MH; Dual Relay Module, 2 amps @ 30VDC
DCP-R2MH-I; Dual Relay Module, 2 amps @ 30VDC with Integrated SCI
DCP-R2ML; Dual Relay Module, 8 amps @ 30VDC
DCP-R2ML-I; Dual Relay Module, 8 amps @ 30VDC with Integrated SCI

Refer to listee's data sheet for additional detailed product description and operational
considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .

*Rev. 01-12-12 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0161 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model ASB detector sounder base. Unit has an intregral audible signal for use with spot-type
detector units. Refer to listee's data sheet for additional detailed product description and
operational considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as a detector base for use with separately listed functionally and electrically
compatible fire alarm control units. Designed specifically for use with listee’s Model ALG-V
(CSFM Listing No. 7272-0410:149) Photoelectric Smoke Detector; Model AIE-EA (CSFM
Listing No. 7271-0410:148) Ionization Smoke Detector; or Model ATG-EA (CSFM Listing No.
7270-0410:147) Heat Detector. Refer to listee’s Installation Instruction Manual for details .

NOTE: These appliances can generate a distinctive three- pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition.

8-24-2004

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0189 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HGOE-R and HGOE-W enclosures. For indoor use only. Refer to listee's data sheet
for additional detailed product description and operational considerations.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as a back box and enclosure for use with separately listed audible and visual
appliances.

XLF: 7300-0569:0124

08-05-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0199 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model TCF-142-M-ST media converter (serial to fiber optic) for use with fire alarm control unit.
Refer to listee's data sheet for additional product description and operational considerations.

RATING: Electrical: 12-42 VDC

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as fire alarm control unit accessory.

02-24-12 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7315-0410:0166 Page 1 of 1

CATEGORY: 7315 -- POWER UNITS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models FN-642-ULADA, FN-842-ULADA and FN-1042-ULADA Indicating Circuit Power


Supply may be followed by -R, -G, -C, or -B. Units are a regulated 12 or 24 VDC power
supply/charger used for supervision and expanded power driving capability of four notification
appliance circuits. Refer to listee's data sheet for additional detailed product description and
operational considerations.

RATING: 115 VAC primary, 12 or 24 VDC secondary

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .

NOTE: The system must have the secondary power supply capable of operating the system for at
least 24 hours battery standby) in the normal condition and followed by not less than 5
minutes of alarm as required by code. The battery circuit must be fully supervised.

XLF: 7315-1335:0109

5-3-2005

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7315-0410:0168 Page 1 of 1

CATEGORY: 7315 -- POWER UNITS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models FN-600ULX-G, -R, -C, -B Power Supply Units. Refer to listee's data sheet for
additional detailed product description and operational considerations.

RATING: 115 VAC input, 12 or 24 VDC output

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction

MARKING: Listee's name, model number, electrical rating, and UL label.

APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control
units. Also suitable for use with access control systems. Authority having jurisdiction should
be consulted prior to installation.

NOTE: For fire alarm use, the standby batteries must provide at least 24 hours standby power during
power loss. The battery circuit must be fully supervised.

XLF: 7315-1335:0104

5-3-2005

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7315-0410:0197 Page 1 of 1

CATEGORY: 7315 -- POWER UNITS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models PE-6SN and PE-10SN Notification Appliance Circuit (NAC) Power Supply Units.
Refer to listee's data sheet for additional detailed product description and operational
considerations.

RATING: Input 120/240 VAC 50/60Hz


Output 24VDC @ 10A

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. For fire alarm use, the unit
must provide battery backup suitable for at least 24 hours.

MARKING: Listee's name, model number, electrical rating and UL label.

APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units
and notification appliances. Authority having jurisdiction should be consulted prior to
installation. The unit can be programmed to generate the three-pulse temporal fire alarm
evacuation signal (for total evacuation) in accordance with NFPA 72, 2010 edition.

XLF: 7315-0328:0189

10-31-11 mt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7320-0410:0194 Page 1 of 1

CATEGORY: 7320 -- SPEAKERS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HSSPKCLPR, HSSPKCLPW speakers and Models HSSPK24CLPPR,


HSSPK24CLPPW, HSSPK24CLPR and HSSPK24CLPW speaker strobes. Models
HSSPKCLPR, HSSPKCLPW are intended for ceiling and wall mount. Other models are
ceiling mounted only. Refer to listee's data sheet for additional detailed product description
and operational considerations.

RATING: Speaker 25 Vrms and 70.7 Vrms


Strobe 21-30 VDC
Flash Rate 60 flashes per minute
Candela 15, 30, 60, 75 & 15/75, 110

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction. All models are intended for
indoor use only and are mounted in a listed double-gang backbox.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as speakers and speaker strobes for use with separately listed compatible fire alarm
control units. Models HSSPK24CLPPR, HSSPK24CLPPW, HSSPK24CLPR and
HSSPK24CLPW speaker strobes are suitable for the hearing impaired applications. For
indoor use only. Refer to manufacturer’s Installation Manual for details .

These devices do not generate a temporal pattern signal. If the distinctive three-pulse
Temporal Pattern Fire Alarm Evacuation signal (for total evacuation).

XLF: 7320-0569:0137

08-08-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7320-0410:0195 Page 1 of 1

CATEGORY: 7320 -- SPEAKERS

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HSSPK24WLPPR, HSSPK24WLPPW, HSSPK24WLPR, HSSPK24WLPW,


HSSPK24-1575WLPPW, HSSPK24-1575WLPPR, HSSPK24-1575WLPR, and
HSSPK24-1575WLPW speaker strobes. All models are intended for indoor use only and are
wall mounted in a listed double-gang backbox. Refer to listee's data sheet for additional
detailed product description and operational considerations.

RATING: Speaker 25 Vrms and 70.7 Vrms


Strobe 24 VDC
Flash Rate 60 flashes per minute
Candela 15, 30, 60, 75 & 15/75, 110 for Model SSPK24WLP series
15/75 fixed candela for Model HSSPK24-1575WLP series

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as speakers and speaker strobes for use with separately listed compatible fire alarm
control units. Both models are suitable for the hearing impaired applications. For indoor use
only. Refer to manufacturer’s Installation Manual for details .

XLF: 7320-0569:0140

08-08-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7300-0410:0211 Page 1 of 1

CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model EMS Graphix Remote Annunciator. Refer to listee's data sheet for detailed product
description and operational considerations.

RATING: 120 Vac

INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as a remote annunciator for use with listee's separately listed FACP's. Refer to
listee’s Installation Instructions Manual for details .

03-23-15 gt

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7135-0410:0187 Page 1 of 1

CATEGORY: 7135 -- AUDIBLE DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HEH24-WR, HEH24-WW horns and HCC24CR, HCC24CW, HCC24PCR,


HCC24PCW, HEC24-15/75WR, HEC24-15/75WW, HEC24-15/75PWR, HEC24-15/75PWW,
HEC24-177WR, HEC24-177WW, HEC3-24WR, HEC3-24WW, HEC3-24PWR,
HEC3-24PWW , WHEC24-75WR, WHEC24-75WW horn strobes . Suffix W indicaying wall,
-W or -R indicating color white or red and -P indicating plain. Refer to listee's data sheet for
additional product description and operational considerations.

RATING: Electrical: 24 VDC

Candela: 15cd, 15/75cd, 30cd, 60cd, 75cd, 110cd or 177cd.

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as horns and horn/strobes for use with separately listed compatible fire alarm control
units. For indoor use only.

The audible in Models HEH24, HEC24, HEC3-24 may produce distinctive tones including:
mechanical, 2400Hz and chime tones in continuous and temporal 3 settings as well as a
whoop tone in either a high or low dBA setting.

XLF: 7135-0569:0122

08-02-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7125-0410:0188 Page 1 of 1

CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Models HES24-1575WR, HES24-1575WW, HES24-177WR, HES24-177WW, HES3-24WR,


HES3-24WW, HES3-24PWR, HES3-24PWW strobe lights; Models HCS24CR, HCS24CW,
HCS24PCR, HCS24PCW strobe lights (synchronization type) and Models HAVSM-R,
HAVSM-W Sync Modules. Intended for indoor use and wall mount only. Refer to listee's data
sheet for additional detailed product description and operational considerations.

RATING: Candela: 15cd, 15cd & 75cd at 00 angle axis


30cd, 60cd, 75cd, 110cd, 177cd.
Model HCS24: Selectable 15cd, 30cd, 75cd, 95cd and 115cd
Model HES3-24: Selectable 15cd, 30cd, 60cd, 75cd and 110cd
Electrical: 21-30 VDC
HAVSM: 8-33 VDC/VFWR
Flash Rate: 60 flashes per minute

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed
compatible fire alarm control units.

XLF: 7125-0569:0123

08-03-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division


CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7135-0410:0191 Page 1 of 1

CATEGORY: 7135 -- AUDIBLE DEVICES

LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3246 Fax (714) 522-2268
Email: mum@hochiki.com

DESIGN: Model WHES24-75WR and WHES24-75WW strobe lights. Units employ a strobe flash tube
and electronic trigger circuit mounted on a printed wiring board with a clear lens. Unit is
intended for indoor use, or outdoor use when combined with enclosure Model HGOE only.
Unit is for private mode signaling use only. Refer to listee's data sheet for additional product
description and operational considerations.

RATING: Electrical: 16 - 33 VDC

Candela: 75cd

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model number, electrical ratings and UL label.

APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Not
approved for hearing impaired applications.

XLF: 7300-0569:0127

08-05-11 bh

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other

Date Issued: July 01, 2015 Listing Expires June 30, 2016

Authorized By: JAMES PARSEGIAN, Program Coordinator

Fire Engineering Division

S-ar putea să vă placă și