Documente Academic
Documente Profesional
Documente Cultură
U2N
PAPER-I
PLUMBER
(THEORY)
SEMESTER- II
TIME:3Hrs. MARKS:150
Note:- Attempt all the questions.
AII questions carry equal marks.
This paper carries negative marking 25Vo marks will be deducted for eaeh
answer.
3. When a sewer gets discharged from two or more main sewers, it is called?
a) I-eading sewer b) Trunk sewer
c) Combined sewer d) Intercepting sewer
6, ventilation shafts are provided at the upper end of every branch sewer and they are
generally spaced at a distance of -
a) 500m b) 300m
c) 100m d) 50m
11. Priming of a centrifugal pump may not be necessary, in case the pump is located at -
a) Less than 10m height above the reservoir level
b) Less than 5m height above the reservoir level
c) Immediately above reservoir level
d) Below reservoir level
13. The height of porcelain urinal stall bowl type above the floor level usually is -
a) 30cm b) 50cm
c) 75cm d) 100cm
20. When the level of the source is higher than the level of the consumer place is
generally supplied by -
a) Pumping system b) Gravity system
c) Pumping and gravity d) Radial system Contd...3/-
l6tBtCE-AUE _3-
24. The layout of distribution system, in which water flows towards the outer periphery is
a) Dead end system b) Grid iron system
c) Ring system d) Radial system
25. Pump commonly used for lifting water in water supply mains is -
a) Centrifugal pump b) Reciprocating pump
c) Axial flow pump d) Rotary type pump
26. A valve which operates automatically when the pressure in the pipe exceeds the set
pressure is called -
a) Safety valve b) Relief valve
c) Sluice valve d) Reflux valve
28. The type ofjoint used in joining plain ends of cast iron pipes is -
a) Flanged joint b) Flexible joint
c) Dresser coupling joint d) Socket & spigot joint
29. The max. Pressure that the pipe can withstand without any leakage during hydro static
pressure test is -
a) Working pressure b) Test pressure
c) Design pressure d) Max.pressure
Contd...4/-
t6lBlcls-uzn
@ -4-
33. The type of system for collecting both foul soil waste and unfoul waste from the
building in a single pipe is called -
a) Two pipe sYstem b) One pipe system
c) Combined sYstem d) Single system
are
36. Pedastal type wash basins are used in thin partition walls where appliances
a) HeavY b) I-ess
c) More. d) VerY less
to
40. The trap provided at junctions of house drain to convey sewage from building
public sewer is called -
a) Gully trap b) Grease traP
c) Floor trap d) lntercePting traP
44. The house drain should be provided with ...""""""' trap for connecting it from sewer'
a) Intercepting b) Floor
c) Gully d) Soil
Contd...5/-
l6IBtCtS-2nB
@ -s-
45. The tlpe test used for checking any leakages in joints is called..........test.
a) Hldraulic b)Air
c) Smell d) Smoke
50. One of the factor responsible for causing corrosion of metals are -
a) Iron b) co
c) Moisture d)o