Sunteți pe pagina 1din 12

24 Inch Range Line

Produced By: Don Alexander 08-PPT-RA-01

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 1
GE 24 Inch Range Line
Manual Clean
JCAS730 JCAS745

Coil CookTop Ceran CookTop


8” 3 x 6” 2 x 6” 2 x 8”
TOD Timer TOD Timer
Storage Drawer Storage Drawer
Outlet Outlet
WW available WW/BB/SS available

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 2
GE 24 Inch Range Line
Self Clean
JCAP750 JCAP760 JCAP765

Coil CookTop Ceran CookTop Ceran CookTop


2 x 6” 2 x 8” 2 x 6” 2 x 8” 2 x 6” 8” 5/8”
ERC Timer ERC Timer ERC Timer
Storage Drawer Storage Drawer Storage Drawer
Outlet Outlet Outlet
WW available WW/BB/SS available Mirror Glass Window
WW/BB/SS available
mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 3
GE 24 Inch Range Line
TOD Timer

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 4
GE 24 Inch Range Line
ERC Timer

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 5
GE 24 Inch Range Line
ERC Timer

Special Features
• 12 Hour Shut-Off
•Fahrenheit or Celsius Temperature Selection
•Control Lockout
•Tones at the End of a Timed Cycle
•12 Hour, 24 Hour or Clock Black-Out
•Cook and Hold
•Changing the Speed of the + or – Pads
•Sabbath Mode
•Sales demo Mode

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 6
GE 24 Inch Range Line
ERC Timer
Failure codes Mini-Manual

FAILURE CODE MEANING COMMENTS

F0 CANCEL / OFF Key input failure * Replace control

Over temperature inside oven * Welded relay contacts * High Resistance in oven sensor leads / connectors
cavity as measured by sensor (especially at the sensor in rear )
F2
over 650ºF unlatched or 915ºF
latched
* Disconnect power. Disconnect sensor harness from control Measure sensor
Open Oven Sensor (Over 2900
F3 resistance (while leads) to be 1080 ohms at room temperature with 2 ohms per degree
ohms)
change. * Look for damage harness terminals if not bad sensor
* Disconnect power. Disconnect sensor harness from control Measure sensor
Shorted Oven Sensor (under 950
F4 resistance (while leads) to be 1080 ohms at room temperature with 2 ohms per degree
ohms)
change. * Separate sensor from harness to determine fault

F5 Sensor Circuit supervisor failure * Replace control

F7 Shorted Matrix or START key * Replace control

F8 EEPROM data shift failure * If repeated, replace control


Cooling fan stall or other cause of
F9 open thermoswitch in blue latch * Suspect cooling fan or air flow
leads

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 7
GE 24 Inch Range Line
To Open Cooktop – Latch needs to be released with a putty
knife

FAD
•Fan Apparency device

•The FAD is a low voltage thermal switch

•The FAD is connected on the ERC 5 wires


connector on terminal 2 (Blue wire)

•The FAD is active during all operations

• The FAD is on the lock switch circuit

•The FAD is mounted on the air duct below the


cooktop. Opens at 295°f +/- 7°f and closes
when temperature cool below 255 +/-11°f

•If the thermal switch opens during Bake mode,


temperature below 600°f. Program is cancelled
LOCK MOTOR will run and word “LOCKED”
and “DOOR” will be flashing in display.

•ERC control will go to an F9 failure

•Oven on Self Clean and surface of air duct


temperature rise above 295°f control will go to
F9 failure

•The color dot on the FAD indicates thermal


operating range

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 8
GE 24 Inch Range Line
Door Lock

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 9
GE 24 Inch Range Line
Range Back

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 10
GE 24 Inch Range Line
Control Board

Cooling Fan

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE. March 2008 11
GE 24 Inch Range Line
ERC Timer
Wiring Diagram

mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE.


12
March 2008