CALCULATION NOTE

ALLOWABLE STRESS DESIGN

1. GENERAL DATA

● Customer: LEVERAGE CORPORATION PROVISIONES SA


● Type: Double girder
● Capacity: 5t
● Span: 25 m
● Hoist: MISIA - type XM312NS4H7A/53A (s/n 109363), weight 610 kg + electrical
parts 280 kg
● Carriages: DG38Z (s/n 109364)

2. STATIC SCHEME

Evaporiticos Calculation note.R0 1


3. LOADS

3.1 VERTICAL LOADS (CMAA 70)

● Dead Load (DL): 5,300 kg (one beam) Dead Load Factor (DLF): 1.2
● Trolley load (TL): 305 kg + 280 kg Trolley Load Factor (TLF): 1.2
● Lifted Load (LL): 5,000 kg (2,500 kg) Hoist Load Factor (HLF): 1.5
● Vertical Inertia Forces (VIF) + Inertia Forces from Drives (IFD) + 5% Vertical Loads

P = 1.05 (1.2 x 5,300 + 1.2 x 585 + 1.5 x 2,500) = 11,350 daN

3.2 HORIZONTAL LOADS

Horizontal Load = 0

4. REACTIONS
RA = RB = P ½ = 5,675 daN

5. BENDING
M PxL 7,095,000 daN x cm
= —–––– =
4

Evaporiticos Calculation note.R0 2


6. HOLLOW BEAM DATA

Ix = 378,165 cm4

Wx = 7,415 cm3
Material: S235JR-EN10025 or similar

sadm = 1,600 daN/cm 2

E = 2,100,000 daN/cm2

7. STRESSES

M 7,095,000 2
s = —–– < sadm s = —––––—–– = 950 daN/cm
Wx 7,415

We consider the bending moment only because the torque moment (due to the wheel
lateral loads and to the rail, whose axis is not on the beam axis) is neglectable.

Evaporiticos Calculation note.R0 3


8. DEFLECTION

8.1 The maximum vertical deflection of the girder produced by the weight of the hoist, trolley
and rate load shall not exceed 1/888 of the span.
Vertical inertia forces shall not be considered in determining deflection. (3.5.5.1 CMAA
70).
F = TL + LL = 4,450 kg

L
fmax = —––– = 2.815 cm
888

F x L3
f = —––––– < f max f = 1.84 cm
48 x E x I x

8.2 Vertical deflection of the girder due to dead load

q = 212 kg/m

5 x q x L4
f = —–––––––– = 1.35 cm
584 x E x IX

Evaporiticos Calculation note.R0 4


9. WEBS AND FLANGES

9.1 WEBS - BUCKLING (European Code)

() ( )
9.1.1 F 230,000 h ta 2
—----------- < —–––––––– 1 + 2 x —–- x —––– N/mm
Ta x beff u a h

5.56 < 18.44

9.1.2 F
—---------------- < 1.15 x sadm
(
t a x c + 2t )
22.26 < 184

Evaporiticos Calculation note.R0 5


9.2 FLANGES

FC = FT = M/d

F F
s = —C = —T = 1,458 daN/cm 2
A fl A fl

10. DESIGN LIMITATIONS (3.5.1 CMAA 70)


Proportions
L = Span = 25,000 mm
h = depth of girder = 1,020 mm
b = distance between web plates = 392 mm
L/h should not exceed 25 25,000
—–––— = 24.5
1,020

L/b should not exceed 65 25,000


—––— = 63.7
392

Evaporiticos Calculation note.R0 6