FIELD COMPONENT MANUAL 4 - AA 3

OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 1 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

MCS - LCB_II
List of Installation Parameters

Authorization Date D1: 27-Jun-1995


Running on PCB: GCA 21240 D1 - D3

GDA 21240 D1 - D3
Software Version: GAA 30082 BAC

Document Revision:
24 - May - 93 GAA 30082 AAA J. Schulte - Original Document
03 - Dec - 93 GAA 30082 AAB A.Gerwing
- OTIS 2000 features add.
29 - Apr - 94 GAA 30082 AAC M. Hnida
- Triplex parameter added
02 - Jun - 94 GAA 30082 AAD M. Hnida
- Secure Access revised
16 - Jun - 94 GAA 30082 AAE J. Schulte
- BSM mode added
17 - Jan - 95 GAA 30082 BAA J. Schulte
- MCS220M, LSVF-W, ELD,
REM III added
06 - Jun - 95 GAA 30082 BAB A. Gerwing - not distributed
27 - Jun - 95 GAA 30082 BAC A.Gerwing - CPC-TYP, N+2,
ELD-MSG, ELD-DOOR

Copyright 1995, OTIS GmbH Berlin


No part of this document may be copied or reproduced in any form or by any
means without the prior written consent of OTIS GmbH.
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 2 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

System: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 TOP 2 Top position:


1 (1) 31
1 LOBBY 0 Lobby position:

0 (1) 31
2 BOTTOM 0 Bottom position:

0 (1) 30
3 CFT-P 255 Cafeteria Position:

0 (1) 31
> 31 Disabled
4 OPERAT 1 Operation FCL/DCL/SAPB:

0 FCL
1 DCL
2 SAPB
5 EN-BSM 0 Enable BSM mode (for DCL: both Up- and Down Hall Calls at lobby):

0 Disabled
1 Enabled
6 CONFIG 0 General configuration:

0 ETO
1 NAO
7 PI 4 Type of serial Position Indicator:

0 7/16 Segment
1 Multil.
2 Australian Dot Matrix
3 Australian Dot Matrix with CUDL/CDDL
4 OTIS 2000: LCD and ELD
8 ELD-fOPG 20 front door movement time: opening

0 (0.1) 10.0 s
0 = automatic (not yet implem.)
9 ELD-fCLG 20 front door movement time: closing

0 (0.1) 10.0 s
0 = automatic (not yet implem.)
10 ELD-rOPG 20 rear door movement time: opening

0 (0.1) 10.0 s
0 = automatic (not yet implem.)
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 3 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

System (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

11 ELD-rCLG 20 rear door movement time: closing


0 (0.1) 10.0 s
0 = automatic (not yet implem.)
12 ELD-LNG 5 set Language for ELD:

0 (1) 19
0 SwiGer, 1 SwiFRA, 2 SwiIta, 3 Fra, 4 Italy,
5 UK, 6 Spain, 7 Nether, 8 Ger, 9 Aus,
10 Sweden, 11 Luxem, 12 Belg, 13 Por, 14 Egy,
15 Denmar, 16 SthAfr, 17 Finlnd, 18 Ara, 19 Kuw
13 ELD-Sym1 0 Enable Non-Smoking symbol:

0 Disabled
1 symbol is displayed
R) 14 ELD-DOOR 0 select type of door display:

R) 0: 1 COP for 1 door or


R) 1: 2 COPs for 2 doors
R) only 1 COP for 2 doors
R) 15 ELD-MSG 0 enables customer messages:
R) 0: no customer messages are displayed by ELD
R) 1: customer messages are enabled (use SETUP-ELD
R) to define the texts)
16 EN-SFR 0 Enable SFR (signal flicker):

0 Disabled
1 Enabled
17 LR-T 20 FAN (LR) time:

0 (1) 255 s
18 EN-HLC 0 Enable Hall Lanterns on car calls:

0 Disabled
1 HLC
2 HL also during closing
3 HLC and during door closing
19 HDL-TY 0 Hall Direction Lantern Type of OTIS 2000 Hall Button Box:

0 Direction Indicator
1 Hall Lantern
20 HL-SET 0 Hall Lantern/Gong Setup:

0 HL/G at same pins


1 HL/G at 1 2/3 4
2 HL/G at 3 4/1 2
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa
European and Transcontinental Vintage : 01 / 8
Operations Software Data
PRODUCT Page : 4 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

System (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

21 CR-DIR 0 Correction Fast Run Preferred Direction:


0 Down
1 Up
22 EN-RR 0 Enable Reduced Run (RR):

0 Disabled
1 Enabled (short or medium run)
23 DZCNT 1 Use DZ for SL counting (for Short Run):

0 Disabled
1 Enabled
24 EN-DZI 0 Enable DZI (Door Zone Indicator):

0 Disabled
1 Enabled (only if no Door ByPass)
25 ERO-TYP 0 Define ERO type

R) 0 without limit
1 with limit at terminal landings (same as TCI-limit)
R) 2 ERO-input disabled (for LCB_II version D2)
26 C-CHK 0 Enable C-Circuit Check:

0 Disabled
1 Enabled
27 MD/AES 0 select use of MD input (P7:9, only MCS220M):

0 not connected
R) 1 MD: DCS-input for Multi Door (manual plus autom. landing
doors)
R) 2 AES: ES-input if RSS or ESB is used
R) 28 CPC-TYP 0 select use of CPC outputs:

R) 0 car position contact


R) 1 'car here' light
2 french SSM
R)
R) 29 N+2 WIRE 0 enable 3 wire buttons:
R) 0 normal car and hall buttons
R) 1 3 wire car buttons
R) 1 3 wire hall buttons
R) 1 3 wire car and hall buttons
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 5 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

OCSS: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 CPR-T 20 Car Call Preference:


0 (0.1) 25.5 s
1 ARD-P 255 Automatic Return Device Position:

0 (1) 31
> 31 Disabled
2 ARD-T 0 Set Delay for ARD (Automayic Return Device) mode:

0 (10) 2550 s
3 L-PARK 0 Lobby Park Option:

0 Disabled
1 Enabled
4 CTL/PKS 0 Select CTL or PKS switch:

0 CTL switch is connected


1 PKS switch is connected
5 PKS-P 255 Parking Service Position:

0 (1) 31
> 31 Disabled
6 PKS-TY 0 Parking Shutoff Type:

0 ETO
1 NAO
2 ETO with door open after shutdown
7 PKS-T 0 Parking Shutoff Time:

0 (1) 255 s
8 PKS-DO 0 PKS default door:

0 Both doors will open at PKS-P


1 Only front door opens
2 Only rear door opens
9 EN-SHB 0 Enable Separate Hall Buttons:

0 Normal HB-operation
1 Rear HB as Separate Riser
10 DCP-T 50 Time until DCP-mode (delayed car protection):

25 (1) 255 s
11 CTL-DO 0 CTL default door (car to any landing):

0 Both doors will open at CTL-P


1 Only front door opens
2 Only rear door opens
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 6 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

OCSS (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

12 CTL-P 255 CTL (Car To Any Landing) position:


0 (1) 31
> 31 Disabled
13 ANS 0 ANS (anti nuisance service):

0 Disabled
>0 Number of calls to trigger ANS
14 ATT 0 ATT (Attendant Service) type:

0 Start with DCB or RDCB


1 Start with ATTU or ATTD
2 NAO (USA)
15 ISC 0 Independent Service:

0 Start on CCB
1 Start on DCB
2 Start on ISD/ISU
3 NAO (USA)
16 CTL-TY 0 Select Car To Landing Type:

0 ETO
1 NAO
17 SPEECH 0 Speech Mode:

0 Floor message on CC only


1 Floor message also on HC
18 DOC 0 Door Reopen Count:

0 No limit
1 (1) 255 Number of allowed door reopenings
19 DS-CCB 0 Disable CCs behind moving car:

0 CCs behind allowed


1 CCs behind not allowed
20 DS-DOB 0 Disable DOB button:

0 DOB/RDOB always enabled


1 DOB disabled if door closed
2 RDOB disabled if door closed
3 Both disabled if door closed
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 7 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Group: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 GRP-NO 1 Car identifier in group:


1 (1)3
1 GROUP 1 Number of cars in group:

1 (1)3
2 CNL 1 Cars parking in Lobby:

1 (1)3
3 MIT-ST 0 MIT (Moderate incomming traffic) Startdelay:

0 (1)255 s
4 MIT-T 0 MIT Time-Out:

0 (1)255 s
5 MIT-VD 0 MIT Variable Interval Dispatch:

0 (1)255 s
6 DUPK-P 255 Dual Up Peak Border Position:

0 (1)31
> 31 Disabled
7 DUPK-G 0 Dual Up Peak Group:

0 Car belongs to subgroup 1


1 Car belongs to subgroup 2
8 MOT-T 0 MOT (Moderate Outgoing traffic) Time-Out:

0 (1)255 s
9 EN-UCB 0 Enable Up Call Bypass:

0 Disabled
1 Enabled
10 TFS-P 255 Transfer Floor Position:

0 (1)31
> 31 Disabled
11 PARK-1 255 Park Clock Position 1:

0 (1)31
> 31 Disabled
12 PARK-2 255 Park Clock Position 2:

0 (1)31
> 31 Disabled
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 8 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Group (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

13 PARK-3 255 Park Clock Position 3:


0 (1) 31
> 31 Disabled
14 PARK-4 255 Park Clock Position 4:

0 (1) 31
> 31 Disabled
15 PARK-5 255 Park Clock Position 5:

0 (1) 31
> 31 Disabled
16 PARK-6 255 Park Clock Position 6:

0 (1) 31
> 31 Disabled
17 PARK-7 255 Park Clock Position 7:

0 (1) 31
> 31 Disabled
18 PARK-8 255 Park Clock Position 8:

0 (1) 31
> 31 Disabled
19 EN-ZBS 0 Enable separate basement zone:

0 No free car parks in basement zone


1 A free car parks in basement zone
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 9 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Drive: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 DRIVE 1 Drive Type:


0 1-SP
1 2-SP, G-L XADO
2 G-S/D XADO
3 G-L with SL XADO
4 G-L with SL ADO
5 2-SP, G-L ADO
6 G-S/D ADO
7 SPEC60
8 G-D NAO XADO
9 G-D NAO ADO
10 MOT-VLV ADO
11 SOL-VLV ADO
12 MOT-VLV XADO
13 SOL-VLV XADO
14 LSVF ADO
15 LSVF XADO
16 LSVF-W ADO
17 LSVF-W XADO
1 C-TYPE 2 Controller Type:

0 MCS 310 (Europa 2000)


1 MCS 310 CA, HY (Cargo 2000)
2 MCS 120, MCS 220 (OTIS 2000)
3 MCS 220 M (OTIS 2000)
2 1AT 5 1A Time:

0 (0.1) 25.5 s
3 2AT 5 2A Time:

0 (0.1) 25.5 s
4 DDP 32 DDP Time (fast run):

0 (1) 45 s
5 3P 32 3P Time (slow run):

0 (1) 45 s
6 SPEED 100 Speed (fast run mode):

25
40
63
100
160
175
250 cm/s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa
European and Transcontinental Vintage : 01 / 8
Operations Software Data
PRODUCT Page : 10 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Drive (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

7 EN-MPD 0 Enable Motor Protection Device:


0 Disabled
1 Enabled
8 MPD-T 10 Motor Protection Device Time:

0 (1) 254 s
255 wait forever
9 HY-TYP 0 Hydro Drive Type for Hydro:

0 Star - Delta
1 Soft
2 Direct
10 L-T 10 Set Star/Soft Time for Hydro:

0 (0.1) 25.5 s
11 UX-D 20 Set Star/Delta gap / add. Soft Time (L+UX) for Hydro:

0.06 (0.004) 0.2 s


12 UXT-D 0 Set delay between UX and UXT for Hydro: (contract option)

0 (0.1) 1 s
13 EN-PLS 1 Enable PLS1 (Oil-Max-Pressure Limit Switch) for Hydro:

0 Disabled
1 Enabled
14 EN-OTS 1 Enable OTS (Oil-Over Temperature Switch) for Hydro:

0 Disabled
1 Enabled
15 ACD/UXT 0 Select ACD (Anti Creeping Device) or UXT output for Hydro:

0 ACD and UXT disabled


1 ACD enabled
2 UXT enabled (contract option)
16 P-OFF-D 0 Set Power Off delay for LSVF-W

0, 255 Disabled
1 (1) 254 s
17 P-ON-D 10 Set Power On delay for LSVF-W

8 (1) 20 s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 11 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Drive (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

18 EN-J 1 Enable 3-Phase Detection (J-Relay)


0 Disabled
1 Enabled
19 J-T 1 Number of periods necessary to detect a fault

0(1) 4
20 EN-BCD 1 Enable Brake Current Detection:

0 Disabled
1 Enabled
21 BON-D 10 Delay of BCD (after lifted brake)

0(0.1) 10 s
22 BFLT-T 15 Max. fault time of BCD

0(0.1) 10 s
23 BOFF-D 15 Delay of BCD (after fallen brake)

0(0.1) 10 s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 12 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Doors: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 DOOR 2 Type of Doors:


0 FLH
1 9550T & ACG
2 9550T & TLD / DO_2000 (DC-relay)
3 OVL / MRDS
4 OVL & ACG
5 DO_2000 (DO-relay)
6 MCG
7 Kiekert / MLI & ACG
8 Kiekert / MLI & TLD/CLD
1 REAR 2 Type of Rear Doors:

0 FLH
1 9550T & ACG
2 9550T & TLD / DO_2000 (DC-relay)
3 OVL / MRDS
4 OVL & ACG
5 DO_2000 (DO-relay)
6 MCG
7 Kiekert / MLI & ACG
8 Kiekert / MLI & TLD/CLD
2 EN-DDO 0 Enable DDO (double door operation):

0 Disabled
1 Enabled
3 MIXDOR 0 Mixed Dooroperators:

0 Same operators front/rear


1 Different operators front/rear
4 DBP-TY 1 Type of Door Bypass circuit:

0 DBP operated (4-relay)


1 LVC operated (3-relay)
5 SEL-CMR 0 select separate CM relay output (MCS220M)

0 (one door) CMR at RDC-output (P6:10)


1 (two doors) CMR at RSL (IO no. 785)
NOTE: only applicable for FLH, MCG, ACG
6 LDR 0 Limited Door Reversal:

0 Full DOB, full EDP, full LRD


1 Full DOB, limited EDP, full LRD
7 EN-PMO 0 Enable PMO (door time monitoring):

0 Disabled
1 Enabled
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 13 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Doors (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

8 EN-NDG 0 Enable NDG (nudging):


0 Disabled
1 Enabled
9 NDG-T 20 Nudging Time:

0 (1) 255 s
10 EN-CK 0 Enable Cancel Doortime with CCB:

0 Disabled
1 Enabled
11 DW-DLY 10 Debouncing Time of Door Contact DW:

0 (0.1) 25.5 s
12 DO-BEL 0 Open Door Bell Timer:

0 (0.1) 25.5 s
13 MIN-C 20 Min Doortime Car:

0 (0.1) 25.5 s
14 MAX-C 40 Max Doortime Car:

0 (0.1) 25.5 s
15 MIN-H 40 Min Doortime Hall:

0 (0.1) 25.5 s
16 MAX-H 60 Max Doortime Hall:

0 (0.1) 25.5 s
17 DOR-T 0 Door reverse time:

0 (0.004) 1 s
18 RDOR-T 0 Rear door reverse time:

0 (0.004) 1 s
19 DTC-T 20 Door Close Protection Time:

10 (1) 255 s
20 DTO-T 20 Door Open Protection Time:

10 (1) 255 s
21 LOB-NT 40 Lobby Door Time:

0 (0.1) 25.5 s
22 CFT-NT 40 Cafeteria Door Time:

0 (0.1) 25.5 s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 14 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Doors (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

23 SPB-NT 0 Special DOB Door Time:


0 (0.1) 25.5 s
24 DHB-T 120 DHB Doortime:

0 (1) 255 s
25 WCO-T 0 Wild Car Door Time:

0 (0.1) 25.5 s
26 SHO-T 0 Shabat Door Time:

0 (0.1) 25.5 s
27 SHO-LT 0 Shabat Lobby Door Time:

0 (0.1) 25.5 s
28 DAR-T 60 MPD/Hydro Door Open Time:

0 (1) 255 s
29 DXT-T 0 DXT Time (extended door time):

0 (0.1) 25.5 s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 15 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Position Reference Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 LV-MOD 2 Leveling Mode:


0 DZ-STP stop with DZ:
use DZ-DLY (in 4 ms units)
1 LV-STP stop with LVU/LVD:
for CA-MOD=0 (RLEV-2):
set LV-U-D, LV-D-D = 0
for CA-MOD=1 (RLEV-3):
use LVU-5D, LVD-5D (in 4 ms units)
2 DZ-STP stop with DZ, 1LV/2LV:
use LV-U-D, LV-D-D (in 4 ms units)
3 IP-STP stop with IPU, IPD: (for 1-Speed Drive)
use IPU-D, IPD-D (unit depends on
T-BASE)
4 UIS/DIS stop with UIS, DIS: (for Hydraulic Drive)
use LV-U-D for DIS (in 4 ms units)
use LV-D-D for UIS (in 4 ms units)
Note: auto-stop for
- Gamma S/D, Spec_60 and Dynalift on RUN signal (110V input)
- LSVF-W on RN (coded inputs)

1 DZ-TYP 0 DZ coding:
0 DZ = 1LV
1 DZ = 1LV and 2LV
2 POSY operation (if neither RLV nor ADO)
to stop: DZ = 1LV and 2LV
after stop: DZ = 1LV or 2LV
2 DZ-DLY 0 Delay for DZ:

0(0.004) 1 s (LV-MOD = 0)
3 LV-U-D 12 Delay for DZ, 1LV/2LV (in up direction):

0(0.004) 1 s (LV-MOD = 1, 2, 4)
4 LV-D-D 12 Delay for DZ, 1LV/2LV (in down direction):

0(0.004) 1 s (LV-MOD = 1, 2, 4)
5 T-BASE 0 Timebase for IPU-D, IPD-D, 1LS-D and 2LS-D:

0 0.1 s
1 0.004 s
6 IPU-D 0 Delay for IPU:

0(0.1) 25.5 s (T-BASE=0)


0(0.004) 1 s (T-BASE=1)
7 IPD-D 0 Delay for IPD:

0(0.1) 25.5 s (T-BASE=0)


0(0.004) 1 s (T-BASE=1)
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 16 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Position Reference (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

8 1LS-D 0 Delay for 1LS:


0(0.1) 25.5 s (T-BASE=0)
0(0.004) 1 s (T-BASE=1)
9 2LS-D 0 Delay for 2LS:

0(0.1) 25.5 s (T-BASE=0)


0(0.004) 1 s (T-BASE=1)
10 EN-RLV 0 Enable RLV operation:

0 Disabled
1 Enabled
11 RLV-TY 0 RLV - Type:

0 RLV Relevelling
1 DRLV Delayed Relevelling (using DIS1)
12 RL-CNT 3 Limit of RLV steps:

0(1) 255
13 RL-DIS 255 Set RLV time up (DIS lost):

0(0.1) 25.5 s
14 RL-UIS 255 Set RLV time down (UIS lost):

0(0.1) 25.5 s
0(0.004) 1 s (hydraulic drive)
15 RL-U-D 0 Set RLV delay up:

0(0.004) 1 s
16 RL-D-D 0 Set RLV delay down:

0(0.004) 1 s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 17 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Cargo: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 CA-MOD 0 CARGO mode:


0 RLEV/RLEV-2
1 RLEV-3
2 Class-C2 (not authorized yet)

1 LVU-5D 0 Delay for LV stop (UP 0.5 load):


0 (0.004) 1 s
2 LVD-5D 0 Delay for LV stop (DOWN 0.5 load):

0 (0.004) 1 s
3 BI-T 0 Class C2: time-out for Bolts In:

0 (0.004) 1 s
4 BO-T 0 Class C2: time-out for Bolts Out:

0 (0.004) 1 s
5 MVU-T 0 Class C2: time-out for Move Up:

0 (0.004) 1 s
6 MVD-T 0 Class C2: time-out for Move Down:

0 (0.004) 1 s
7 PLS4-T 0 Class C2: time-out for PLS4:

0 (0.004) 1 s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 18 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Emergency: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 ES-TYP 0 Define ES-Type:


0 ESS connected
1 ESB connected (closed door will remain closed)
2 ESB connected (closed door will open)
R) 3 ES-input disabled (for LCB_II version GCA 21240 D2 / D3)
1 EFO-P 255 EFO (emergency fireman operation) position:

0(1) 31
> 31 Disabled
2 EFO-DC 0 EFO with doors closed:

0 Disabled
1(1) 255 s DC time
3 EFO-DO 0 EFO default door:

0 Both doors will open at EFO position


1 Only front door opens
2 Only rear door opens
4 EFO-OP 0 EFO override option:

0 No override possible
1 XEFO input overrides EFO after arrival at return landing
2 After EFS no EFO is permitted if EFO or AEFO are still active
3 Functions 1 + 2 together

5 EFONDG Enable nudging speed for EFO


0 Door closes with full speed
1 Door closes with nudging speed
6 ASL-P 255 ASL (alternate service landing) position:

0 (1) 31
> 31 Disabled
7 EFS-TY 0 Type of EFS (Emergency Fireman Service) (if EFK (ASL) connected):

0 EFO
1 EFS 1 (Aut.)
2 EFS 2 (Man.)
3 ANSI (USA)
4 British Standard
5 Swiss Standard
6 Australia
R) 7 New Zealand
8 EFS 2 (Man. with ESK)
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 19 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Emergency (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

8 EFS-DO 0 EFS default door:


0 Both doors will open position
1 Only front door opens
2 Only rear door opens
9 EFS-RT 0 EFS return time (time EFK must be low to force car back to EFO landing if

EFK is switched on again while in EFS):


0-39 Function disabled
40-255 Time (in 100 ms units) EFK must be low
10 EN-BAK 0 Enable E2P-backup of EFO/EFS:

0 Disable backup
1 Enable backup
11 HDWPOS 0 Hardware position reference:

0 Disabled
1 One contact per floor
2 Binary coded contacts
3 Signal at every odd floor
12 EPO-P 255 EPO (emergency power operation) Position:

0 (1) 31 EPO A/C (position)


EPO E (hydro: bottom)
= 32 EPO B/D (next floor)
EPO F (hydro: next floor down)w
>32 Disabled
13 EPO-DC 0 EPO with doors closed:

0 Disabled
1 (1) 255 s
14 EPO-DO 0 EPO default door:

0 Both doors will open at EPO position


1 Only front door opens
2 Only rear door opens

15 EPO-PR 0 EPO priority if EFO/EFS:


0 No prio for EPO
1 EPO has priority
16 EQO 0 Earthquake Operation Type:

0 California
1 New Zealand
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 20 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Emergency (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

17 EPS-TYP 0 Express Priority Service:


x0 automatic ISC
x1 return to normal
x2 automatic CHCS
0x immediate return
1x stop at next commitable
2x serve car calls en route
18 EHS-T 0 EHS time-out:

0 Disabled
1 (1) 255 s
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 21 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Security: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 EN-FPD 0 Enable FPD (fireproof doors):


0 Disabled
1 Enabled
1 EN-IST 0 Enable IST (intermittent stop):

0 Disabled
1 In up direction only
2 In down direction only
3 In both directions
5 In up direction only, if ISTS active
6 In down direction only, if ISTS active
7 In both directions, if ISTS active
2 IST-P 255 Intermittent Stop Position:

0 (1) 31
>31 Disabled
3 EN-CRO 0 Enable CRO (card reader operation):

0 Disabled
1 Single contact reader
2 Australian Card Key sec type 2
3 Australian Card Key sec type 1
4 Multi contact reader
4 GCBTYP 0 General Control of Buttons type:

0 disabled
1 GCB_1
2 GCB_2
5 RIOT-P 255 RIOT Operation Position:

0 (1) 31
>31 Disabled
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 22 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Security (continued): Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

6 SACTYP 0 Secure Access Type:


1 SAC enabled, without ISC override
3 SAC enabled, with ISC override
5 SAC enabled, without ISC override, clear only if sec. enabled
7 SAC enabled, with ISC override, clear only if security enabled
else SAC disabled
7 SAC-D1 255 Secure Access digit 1:

0 (1) 6
>6 Disabled
8 SAC-D2 255 Secure Access digit 2:

0 (1) 6
>6 Disabled
9 SAC-D3 255 Secure Access digit 3:

0 (1) 6
>6 Disabled
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 23 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Test: Version: GAA 30082 BAC

No. Symbol Default Purpose and Range

0 TPOS 1 255 Test position 1 (automatic test run):


0 (1) 31
> 31 Disabled
1 TPOS 2 255 Test position 2 (automatic test run):

0 (1) 31
> 31 Disabled
2 TDELAY 255 Test Delay for automatic test run:

0 (1) 255 s
3 NoAdrChk 0 Disable safety check: address of TCI, 1LS and 2LS regarding to Std-IO-List

0 RSL safety check enabled


1 RSL safety check disabled
4 NoDW_Chk 0 Disable DW-check during NOR:

0 DW is checked when door open


1 No DW-check during NOR
5 DEBUG 0 Debug Parameter:

0 (1) 255 s
6 DEBUG1 0 Debug Parameter 1:

0 (1) 255 s
7 EN-1CL 0 Enable Init_1CL: default position (Mot_VLV.):

0 Disabled
1 Enabled
8 EN-EVT 0 Enable storage of 10 events into E2PROM:

0 Disabled
1 Enabled
9 EN-CRT 0 Enable contract handling: Operate up to 32 openings:

0 Disabled
1 Enabled
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 24 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

Index DOC, 6 EN-FPD, 21


DOOR, 12 EN-HLC, 3
DOR-T, 13 EN-IST, 21
A DO-BEL, 13 EN-J, 11
ACD/UXT, 10 DRIVE, 9 EN-MPD, 10
ANS, 6 DS-CCB, 6 EN-NDG, 13
ARD-P, 5 DS-DOB, 6 EN-OTS, 10
ARD-T, 5 DTC-T, 13 EN-PLS, 10
ASL-P, 18 DTO-T, 13 EN-PMO, 12
ATT, 6 DUPK-G, 7 EN-RLV, 16
DUPK-P, 7 EN-RR, 4
B DW-DLY, 13 EN-SFR, 3
DXT-T, 14 EN-SHB, 5
BFLT-T, 11 DZCNT, 4 EN-UCB, 7
BI-T, 17 DZ-DLY, 15 EN-ZBS, 8
BOFF-D, 11 DZ-TYP, 15 EN-1CL, 23
BON-D, 11
EPO-DC, 19
BOTTOM, 2
E EPO-DO, 19
BO-T, 17
EPO-P, 19
EFONDG, 18
EPO-PR, 19
C EFO-DC, 18
EPS-TYP, 20
EFO-DO, 18
CA-MOD, 17 EQO, 19
EFO-OP, 18
CFT-NT, 13 ERO-TYP, 4
EFO-P, 18
CFT-P, 2 ES-TYP, 18
EFS-DO, 19
CNL, 7 EFS-RT, 19
CONFIG, 2 EFS-TY, 18 G
CPC-TYP, 4 EHS-T, 20 GCBTYP, 21
CPR-T, 5 ELD-DOOR, 3 GROUP, 7
CR-DIR, 4 ELD-fCLG, 2 GRP-NO, 7
CTL-DO, 5 ELD-fOPG, 2
CTL-P, 6 ELD-LNG, 3
CTL-TY, 6 H
ELD-MSG, 3
CTL/PKS, 5 ELD-rCLG, 3 HDL-TY, 3
C-CHK, 4 ELD-rOPG, 2 HDWPOS, 19
C-TYPE, 9 ELD-Sym1, 3 HL-SET, 3
EN-BAK, 19 HY-TYP, 10
D EN-BCD, 11
DAR-T, 14 EN-BSM, 2 I
DBP-TY, 12 EN-CK, 13 IPD-D, 15
DCP-T, 5 EN-CRO, 21 IPU-D, 15
DDP, 9 EN-CRT, 23 ISC, 6
DEBUG, 23 EN-DDO, 12 IST-P, 21
DEBUG1, 23 EN-DZI, 4
DHB-T, 14 EN-EVT, 23
FIELD COMPONENT MANUAL 4 - AA 3
OTIS No. : GCA 21240 D VIIIa

European and Transcontinental Vintage : 01 / 8


Operations Software Data
PRODUCT Page : 25 / 25
MCS - LCB_II
ADMINISTRATION
List of Installation Parameters Date : 27-Jun-1995

J PARK-2, 7 TPOS1, 23
J-T, 11 PARK-3, 8 TPOS2, 23
PARK-4, 8 T-BASE, 15
PARK-5, 8
L PARK-6, 8
LDR, 12 U
PARK-7, 8
LOBBY, 2 PARK-8, 8 UXT-D, 10
LOB-NT, 13 PI, 2 UX-D, 10
LR-T, 3 PKS-DO, 5
LVD-5D, 17 PKS-P, 5 W
LVU-5D, 17 PKS-T, 5 WCO-T, 14
LV-D-D, 15 PKS-TY, 5
LV-MOD, 15 PLS4-T, 17
LV-U-D, 15 P-OFF-D, 10 1
L-PARK, 5 P-ON-D, 10 1AT, 9
L-T, 10 1LS-D, 16
R
M RDOR-T, 13 2
MAX-C, 13 REAR, 12 2AT, 9
MAX-H, 13 RIOT-P, 21 2LS-D, 16
MD/AES, 4 RLV-TY, 16
MIN-C, 13 RL-CNT, 16
MIN-H, 13 3
RL-DIS, 16
MIT-ST, 7 RL-D-D, 16 3P, 9
MIT-T, 7 RL-UIS, 16
MIT-VD, 7 RL-U-D, 16
MIXDOR, 12
MOT-T, 7
MPD-T, 10 S
MVD-T, 17 SACTYP, 22
MVU-T, 17 SAC-D1, 22
SAC-D2, 22
SAC-D3, 22
N SEL-CMR, 12
NDG-T, 13 SHO-LT, 14
NoAdrChk, 23 SHO-T, 14
NoDW_Chk, 23 SPB-NT, 14
SPEECH, 6
O SPEED, 9
OPERAT, 2
T
P TDELAY, 23
TFS-P, 7
PARK-1, 7
TOP, 2